Multi-Speed Blowers

Multi-Speed Blowers
TM
Multi-Speed
Blowers
Intelli-Sense Multi-Speed Blowers
™
Intelli-Sense Multi-Speed Blowers
Easy selection. Intelli-Sense Blowers take much of the
guesswork out of blower selection. Since they are adjustable
over a broad airflow range, they may be used to exhaust fume
hoods from 3' to 7' in width at full sash open height and 100
fpm face velocity. The blowers may also be used with hoods
from 8' to 16' in width with reduced air volume modifications.
As needs change, the blower settings may be adjusted to
accommodate new airflow requirements. To select the right
blower for your application, follow these four easy steps.
™
TM
•Energy savings
•Up to three speed operation
•One size fits most fume hood applications—
simple to size, adjustable over time
Intelli-Sense Multi-Speed Blowers are weatherized, direct
drive, non-explosion-proof blowers controlled by a two or
three position switch. Each blower has a reliable electronically
commutated motor (ECM), which consumes one third less
energy and is easier and less expensive to maintain than beltdrive motors.
1)If the equivalent resistance* of your ductwork is equal to or less than 100 feet, refer to the Intelli-Sense Blower Quick Selection Guide below and note the nominal inlet blower diameter(s) suitable for your hood width and desired sash height opening. If the equivalent resistance of your ductwork is unknown or exceeds 100 feet, contact Labconco for blower sizing assistance.
The biggest operating expense for many laboratories is the
expense of heating and cooling the air that is exhausted out of
the fume hood. Traditional AC belt-drive blowers typically offer
two operating mode options, off and on. Since many facilities
require that their fume hoods operate 24 hours a day, a hood
with a traditional blower is exhausting large volumes of
tempered air even though it is being used a small percentage
of time. Expensive energy is being wasted.
Intelli-Sense Blower Quick Selection Guide
Protector Blower for use with Blower,
Hood
Width
3'
4'
5'
6'
7'
8'
10'
12'
16'
Saves Energy. The Intelli-Sense Blower provides an economical alternative to traditional on/off blowers. Users may close
the sash and turn the Intelli-Sense Blower switch to standby
mode so that the hood operates at a lower velocity yet fulfills
minimum air exchange requirements. Lower velocity modes
have the added benefit of quieter operation than full velocity
mode.
Hood with Reduced Hood with Full Open
Sash Opening Sash Opening
Height (18”)** Height (28”)**
10", 12"
10", 12"
10", 12"
10", 12"
10", 12"
10", 12"
12"
12"†
12"††
10" Inlet,
CFM
Range
Blower,
12" Inlet,
CFM
Range
10", 12"
175-495
200-495
10", 12"
175-735
200-735
10", 12"
175-955
200-955
12"
175-1100 200-1180
12"
175-1100 200-1410
12"†
175-1100200-1410
12"††
—200-1410
—
—200-1410
—
—200-1410
Minimum CFMs require a damper, sold separately.
2)Choose the blower type that is most compatible with the chemical fumes that will pass through it.
a. Mild to Moderate Corrosive Chemicals. Choose a Coated Steel. Go to page 3.
b.Moderate to Highly Corrosive Chemicals. Choose a Fiberglass. Go to page 4.
c. Highly Corrosive Acids or Perchloric Acid. Choose a PVC. Go to page 5.
Operating the blower at lower speed at night or while the
hood is unoccupied saves money. For example, a 6' fume hood
operating at 100 fpm (735 CFM at $7/CFM/year) at the 18" sash
height at constant volume can cost $5,145 per year to operate.
In contrast, a 6' Hood with an Intelli-Sense Blower used 4 hours
per day with proper fume hood sash closing and blower speed
reduction would cost only $2,578 per year to operate, an annual
savings of approximately 50%.
3)Refer to the Ordering Information for the blowers with the suitable inlet diameter (10" and/or 12").
4)Choose the Catalog Number with the motor electrical configuration that matches your requirements.
a. 115 volts, 50/60 Hz
b.230 volts, 50/60 Hz
Intelli-Sense Blowers include a
blower switch for operating the fume
hood at two or three different speeds.
Operating the hood at a lower speed
while unoccupied saves energy
and money.
*Equivalent resistance of 100 feet is approximately equal to a total of one 90° elbow, one Zero Pressure Weathercap and 75 feet of 10" or 12" diameter straight
duct. If the equivalent resistance of your ductwork exceeds 100 feet,
contact Labconco for assistance or follow the Blower Sizing steps on page 6.
**10" = Intelli-Sense Blowers with nominal 10" inlets,
12" = Intelli-Sense Blowers with nominal 12" inlets
†
Restricted to 80 fpm maximum. Not for use with Perchloric Acid Hoods.
††
Restricted to 60 fpm maximum. Not for use with Perchloric Acid Hoods.
2
Intelli-Sense Multi-Speed Coated Steel Blowers
™
Recommended for low to moderately corrosive applications. For greater corrosion protection, refer to the Fiberglass Blowers and PVC Blowers.
TM
Features & Benefits
•Phenolic coating on impeller and housing is corrosion resistant.
•Powder-coated base and weather cover provide long life in extreme weather.
•Direct drive, UL* listed, ECM motor uses one third less energy than belt drive motors.
•Thermal override protection. RPM speeds are automatically reduced when motor is overloaded.
•Flow-through vent holes and louvers allow air to circulate.
•Removable weather cover allows easy access to ECM motor and impeller shaft.
•Forward curved impellers are balanced to ensure quiet operation and optimum air delivery.
•Speed control box included for mounting on top of customer-supplied fume hood and blower switch and label† for multiple speed operation.
•When blower is properly installed to ductwork, sound levels range from 50 to 70 dba.
•Variable exhaust orientation adjusts to eight outlet positions for installation flexibility (vertical discharge is recommended).
*UL is a trademark of UL LLC, Northbrook, IL.
†Label is factory-prepared for Protector XStream, Premier, XL, Stainless Steel, PVC, and PassThrough Laboratory Hoods, and Basic and Fiberglass 30 Laboratory Hoods. For other hoods, the
switch may require on-site hood modifications or mounting on an adjacent wall. Switch cutout is
0.83" x 1.45" (2.1 x 3.7 cm).
Dimensional Data
Ordering Information
Nominal Inlet Diameter: 10"
Overall Range: 175 CFM @ 0.06" H2O to 1050 CFM @ 1.9" H2O
or 1200 CFM @ 1.0" H2O
18.0" (45.6 cm)
16.7"
(42.5
cm)cm)
18.0"
(45.6
16.7" (42.5 cm)
1.5"
(3.8 cm)1.5"
(3.8 cm)
Catalog
Number
HP
13.75"
(34.9 cm)
13.75"
(34.9 cm)
0.375" (1.0 cm)
DIA.0.375"
MTG. (1.0 cm)
HOLEDIA.
(4)MTG.
HOLE (4)
TOP
TOP
TOP
D
D
A
E
OUTLET WIDTH
E
A
OUTLET WIDTH
INLET
INLET
OUTLET DEPTH
OUTLET DEPTH
B
B
INLET
INLET
15.1" (38.4 cm)
16.7"
(42.5
cm)cm)
15.1"
(38.4
18.0"
(45.6
cm)cm)
16.7"
(42.5
18.0" (45.6 cm)
0.375" DIA.
(1.0)0.375"
cm DIA.
MTG.(1.0)
HOLEcm(4)
MTG. HOLE (4)
FRONT
Dimension
A
B
C
D
E
Inlet
Outlet
Wheel
Catalog# 16-090-60 & 16-090-61
13.75" (34.9 cm)
16.75"
(42.5
cm)cm)
13.75"
(34.9
16.75" (42.5 cm)
F.L. Amps
Nom. Inlet
Dia.
Shipping
Weight
16-090-60
1
115 volts, 50/60 Hz
10
10"
80 lbs. (36 kg)
16-090-61
1
230 volts, 50/60 Hz
6
10"
80 lbs. (36 kg)
Speed (RPM)
Optimum Airflow (CFM) and Static Pressure (inches of water) Range
1800 MAX
750 CFM @ 2.2" to 1050 CFM @ 1.9"
1500
650 CFM @ 1.6" to 1250 CFM @ 0.7"
1250
550 CFM @ 1.1" to 1050 CFM @ 0.5"
1000
400 CFM @ 0.7" to 850 CFM @ 0.33"
750
275 CFM @ 0.37" to 650 CFM @ 0.2"
500
200 CFM @ 0.2" to 450 CFM @ 0.1"
300
175 CFM @ 0.06" to 350 CFM @ 0.08"**
22.9"
(58.1 22.9"
cm)
(58.1 cm)
C
15.6"
(39.7 15.6"
cm) C
(39.7 cm)
Motor Data
Electrical Requirements
Ordering Information
Nominal Inlet Diameter: 12"
Overall Range: 200 CFM @ 0.08" H2O to 1350 CFM @ 1.5" H2O
Catalog
Number
HP
1.5"
(3.81.5"
cm)
(3.8 cm)
SIDE
Catalog# 16-090-62 & 16-090-63
7.2" (18.2 cm)
8.6" (21.7 cm)
7.0" (17.8 cm)
9.0" (22.9 cm)
8.1" (20.7 cm)
10.5" (26.7 cm)
6.8" (17.3 cm)
9.0" (22.9 cm)
9.25" (23.5 cm)
12.5" (31.8 cm)
10.9" (27.6 cm) ID
12.25" (31.1 cm) OD
5.5" (14.0 cm) D x 10.0" (25.4 cm) W
7.0" (17.8 cm) D x 13.5" (34.3 cm) W
9.2" (23.3 cm) Dia. x 4.25" (10.8 cm) W 12.2" (31.0 cm) Dia. x 5.25" (13.3 cm) W
Motor Data
Electrical Requirements
F.L. Amps
Nom. Inlet
Dia.
Shipping
Weight
16-090-62
1
115 volts, 50/60 Hz
10
12"
85 lbs. (39 kg)
16-090-63
1
230 volts, 50/60 Hz
6
12"
85 lbs. (39 kg)
Speed (RPM)
Optimum Airflow (CFM) and Static Pressure (inches of water) Range
1125 MAX
1200 CFM @ 1.6" to 1350 CFM @ 1.5"
1000
1100 CFM @ 1.3" to 1450 CFM @ 1.2"
750
800 CFM @ 0.8" to 1150 CFM @ 0.7"
500
550 CFM @ 0.33" to 725 CFM @ 0.3"
300
200 CFM @ 0.08" to 450 CFM @ 0.1"**
**Minimum
CFMs require a damper, not included.
See Blower Performance Curves on back cover.
3
Intelli-Sense Multi-Speed Fiberglass Blowers
™
Ideal for fume hood exhaust systems in moderate to highly corrosive conditions.
They are not recommended for use with perchloric acid. Please refer to PVC
Blowers for perchloric acid use.
TM
Features & Benefits
•Housings are made from molded fiberglass reinforced polyester for durability and long life.
•Balanced, forward-curved impellers made of injection-molded polypropylene resist corrosive atmospheres, operate quietly and provide optimum air delivery.
•Powder-coated base and weather cover provide long life in extreme weather.
•Direct drive, UL* listed, ECM motor uses one third less energy than belt drive motors.
•Inlet and discharge diameters are sized to receive rigid PVC ducting material directly for easy installation.
•Thermal override protection. RPM speeds are automatically reduced when motor is overloaded.
•Flow-through vent holes and louvers allow air to circulate.
•Speed control box included for mounting on top of customer-supplied fume hood and blower switch and label* for multiple speed operation.
•When blower is properly installed to ductwork, sound levels range from 50 to 70 dba.
•Variable exhaust orientation adjusts to eight outlet positions for installation flexibility (vertical discharge is recommended).
*UL is a trademark of UL LLC, Northbrook, IL.
†Label is factory-prepared for Protector XStream, Premier, XL, Stainless Steel, PVC, and PassThrough Laboratory Hoods, and Basic and Fiberglass 30 Laboratory Hoods. For other hoods, the
switch may require on-site hood modifications or mounting on an adjacent wall. Switch cutout is
0.83" x 1.45" (2.1 x 3.7 cm).
Dimensional Data
1.5"
(3.8 cm) 1.5"
(3.8 cm)
K
M
M
Ordering Information
0.375" (1.0 cm)
DIA. MTG.
0.375" (1.0 cm)
HOLE (4)
DIA. MTG.
HOLE (4)
K
Nominal Inlet/Outlet Diameter: 10"
Overall Range: 175 CFM @ 0.06" H2O to 1025 CFM @ 1.6" H2O
OUTLET
OUTLET
Catalog
Number
HP
16-090-64
16-090-65
TOP
D
B
INLET
C
TOP
TOP
D
E
F
F
OUTLET
OUTLET
E
B
INLET
INLET
INLET
H
GC
H
1
1
Motor Data
Electrical Requirements
F.L. Amps
Nom. Inlet
Dia.
Shipping
Weight
115 volts, 50/60 Hz
230 volts, 50/60 Hz
10
6
10"
10"
80 lbs. (36 kg)
80 lbs. (36 kg)
Speed (RPM)
Optimum Airflow (CFM) and Static Pressure (inches of water) Range
1800 MAX
1500
1250
1000
750
500
300
750 CFM @ 1.7" to 1025 CFM @ 1.55"
600 CFM @ 1.2" to 1050 CFM @ 0.5"
500 CFM @ 0.8" to 850 CFM @ 0.37"
400 CFM @ 0.6" to 700 CFM @ 0.25"
300 CFM @ 0.3" to 475 CFM @ 0.12"
200 CFM @ 0.12" to 325 CFM @ 0.06"
175 CFM @ 0.06" to 275 CFM @ 0.04"**
G
0.6"
(1.6 cm) 0.6"
(1.6 cm)
L
M
N
0.375" (1.0 cm) DIA.
MTG.0.375"
HOLE (1.0
(4) cm) DIA.
1.5"
MTG. HOLE (4)
(3.8 cm) 1.5"
A (3.8 cm)
A
L
M
N
FRONT
Ordering Information
K
P
Nominal Inlet/Outlet Diameter: 12"
Overall Range: 200 CFM @ 0.08" H2O to 1400 CFM @ 0.87" H2O
or 1150 CFM @ 1.4" H2O
K
P
SIDE
Dimension
Catalog# 16-090-64 & 16-090-65
Catalog# 16-090-66 & 16-090-67
A
B
C
D E
F
G
H
K
L
M
N
P
INLET
OUTLET
WHEEL
7.1" (18.1 cm)
12.7" (32.2 cm)
10.5" (26.7 cm)
8.75" (22.2 cm)
13.9" (35.3 cm)
7.5" (19.1 cm)
15.6" (39.7 cm)
22.9" (58.1 cm)
13.75" (34.9 cm)
15.1" (38.4 cm)
16.7" (42.5 cm)
18.0" (45.6 cm)
16.75" (42.6 cm)
10.4" (26.4 cm) OD
10.75" (27.3 cm) ID
9.9" (25.2 cm) Dia. x 3.3" (8.4 cm) W
8.0" (20.3 cm)
13.2" (33.5 cm)
12.0" (30.5 cm)
10.0" (25.4 cm)
15.9" (40.3 cm)
8.5" (21.6 cm)
15.6" (39.7 cm)
22.9" (58.1 cm)
13.75" (34.9 cm)
15.1" (38.4 cm)
16.7" (42.5 cm)
18.0" (108.0 cm)
16.75" (42.6 cm)
12.4" (108.2 cm) OD
12.75" (32.4 cm) ID
11.8" (30.0 cm) Dia.
x 4.25" (10.8 cm) W Catalog
Number
HP
16-090-66
16-090-67
1
1
Motor Data
Electrical Requirements
F.L. Amps
Nom. Inlet
Dia.
Shipping
Weight
115 volts, 50/60 Hz
230 volts, 50/60 Hz
10
6
12"
12"
85 lbs. (39 kg)
85 lbs. (39 kg)
Speed (RPM)
Optimum Airflow (CFM) and Static Pressure (inches of water) Range
1400 MAX
1300
1250
1125
1000
750
500
300
960 CFM @ 1.7" to 1100 CFM @ 1.7"
900 CFM @ 1.5" to 1150 CFM @ 1.4"
850 CFM @ 1.3" to 1400 CFM @ 0.87"
780 CFM @ 1.1" to 1310 CFM @ 0.75"
700 CFM @ 0.87" to 1180 CFM @ 0.62"
450 CFM @ 0.4" to 860 CFM @ 0.34"
300 CFM @ 0.2" to 575 CFM @ 0.12"
200 CFM @ 0.08" to 450 CFM @ 0.1"**
**Minimum CFMs require a damper, not included.
See Blower Performance Curves on back cover.
4
Intelli-Sense Multi-Speed PVC Blowers
™
Handle extremely corrosive atmospheres produced by high order oxidizers
such as perchloric acid. They have a drain connection on the lower portion of
the housing so that a washdown system can be utilized.
TM
Features & Benefits
•Housings are vacuum formed from unplasticized Type I polyvinyl chloride for complete corrosion protection.
•Impellers made of injection molded PVDF resist highly corrosive atmospheres, operate quietly and provide optimum delivery.
•Powder-coated base and weather cover provide long life in extreme weather.
•Direct drive, UL* listed, ECM motor uses one third less energy than belt drive motors.
•Inlet and discharge diameters are sized to receive rigid PVC ducting material directly for easy installation. Blowers are available with 10" and 12" inlet/outlet connections.
•Thermal override protection. RPM speeds are automatically reduced when motor is overloaded.
•Flow-through vent holes and louvers allow air to circulate.
•Speed control box included for mounting on top of customer-supplied fume hood and blower switch and label* for multiple speed operation.
•Convenient access to impeller assembly provides for easy maintenance.
•When blower is properly installed to ductwork, sound levels range from 50 to 70 dba.
•Variable exhaust orientation adjusts to eight outlet positions for installation flexibility (vertical discharge is recommended).
Dimensional Data
*UL is a trademark of UL LLC, Northbrook, IL.
†Label is factory-prepared for Protector XStream, Premier, XL, Stainless Steel, PVC, and PassThrough Laboratory Hoods, and Basic and Fiberglass 30 Laboratory Hoods. For other hoods, the
switch may require on-site hood modifications or mounting on an adjacent wall. Switch cutout is
0.83" x 1.45" (2.1 x 3.7 cm).
18.0" (45.6 cm)
18.0" (45.6 cm)
16.7" (42.5 cm)
16.7" (42.5 cm)
1.5"
1.5"
(3.8 cm)
(3.8 cm)
0.375" (1.0 cm)
0.375"
DIA.
MTG.(1.0 cm)
DIA.(4)
MTG.
HOLE
HOLE (4)
13.75"
(34.913.75"
cm)
(34.9 cm)
Ordering Information
Nominal Inlet/Outlet Diameter: 10"
Overall Range: 175 CFM @ 0.06" H2O to 1100 CFM @ 1.3" H2O
OUTLET
OUTLET
Catalog
Number
HP
TOP
D
B
D
16-090-68
16-090-69
TOP
TOP
F
E
F
E
OUTLET
OUTLET
B
INLET
INLET
C
C 15.6"
(39.715.6"
cm)
(39.7 cm)
INLET
INLET
15.1" (38.4 cm)
15.1" (38.4 cm)
16.7" (42.5 cm)
16.7" (42.5 cm)
18.0" (45.6 cm)
18.0" (45.6 cm)
B
A
A
13.75" (34.9 cm)
13.75"(42.5
(34.9cm)
cm)
16.75"
16.75" (42.5 cm)
Catalog# 16-090-68 & 16-090-69
7.1" (18.1 cm)
Catalog# 16-090-70 & 16-090-71
8.0" (20.3 cm)
12.7" (32.2 cm)
13.2" (33.5 cm)
12.0" (30.5 cm)
C
10.5" (26.7 cm)
D
8.75" (22.2 cm)
10.0" (25.4 cm)
E
13.9" (35.3 cm)
15.9" (40.3 cm)
F
INLET
Nom. Inlet
Dia.
Shipping
Weight
115 volts, 50/60 Hz
230 volts, 50/60 Hz
10
6
10"
10"
80 lbs. (36 kg)
80 lbs. (36 kg)
Speed (RPM)
Optimum Airflow (CFM) and Static Pressure (inches of water) Range
1800 MAX
1500
1250
1000
750
500
300
650 CFM @ 1.7" to 1100 CFM @ 1.3"
600 CFM @ 1.2" to 1050 CFM @ 0.5"
500 CFM @ 0.8" to 900 CFM @ 0.33"
375 CFM @ 0.6" to 700 CFM @ 0.2"
300 CFM @ 0.3" to 525 CFM @ 0.12"
200 CFM @ 0.12" to 350 CFM @ 0.06"
175 CFM @ 0.06" to 275 CFM @ 0.04"**
Nominal Inlet/Outlet Diameter: 12"
Overall Range: 200 CFM @ 0.12" H2O to 1180 CFM @ 1.7" H2O
1.5"
1.5"cm)
(3.8
(3.8 cm)
Catalog
Number
HP
SIDE
F.L. Amps
Ordering Information
0.375" (1.0 cm) DIA.
0.375"
(1.0 cm)
MTG. HOLE
(4) DIA.
MTG. HOLE (4)
FRONT
Dimension
A
22.9"
(58.122.9"
cm)
(58.1 cm)
1/2"
1/2"
NPT DRAIN
NPT DRAIN
1
1
Motor Data
Electrical Requirements
7.5" (19.1 cm)
8.50" (21.6 cm)
10.4" (26.4 cm) OD
12.4" (31.4 cm) OD
OUTLET
10.75" (27.3 cm) ID
12.75" (32.4 cm) ID
WHEEL
9.9" (25.2 cm) Dia.
x 3.3" (8.4 cm) W
11.8" (30.0 cm) Dia.
x 4.25" (10.8 cm) W
16-090-70
16-090-71
1
1
Motor Data
Electrical Requirements
F.L. Amps
Nom. Inlet
Dia.
Shipping
Weight
115 volts, 50/60 Hz
230 volts, 50/60 Hz
10
6
12"
12"
85 lbs. (39 kg)
85 lbs. (39 kg)
Speed (RPM)
Optimum Airflow (CFM) and Static Pressure (inches of water) Range
1500 MAX
1400
1250
1000
750
500
300
900 CFM @ 1.9" to 1025 CFM @ 1.8"
900 CFM @ 1.8" to 1180 CFM @ 1.7"
850 CFM @ 1.37" to 1325 CFM @ 0.8"
675 CFM @ 0.9" to 1100 CFM @ 0.6"
450 CFM @ 0.45" to 825 CFM @ 0.33"
300 CFM @ 0.20" to 550 CFM @ 0.12"
200 CFM @ 0.08" to 400 CFM @ 0.1"**
**Minimum CFMs require a damper, not included.
See Blower Performance Curves on back cover.
5
Ductwork and Accessories
Static Pressure Losses for Ductwork
Zero Pressure
Weathercap
Typical Fume Removal System
TM
Nominal Diameter/Inches
681012
16
Airflow/CFM
Static Pressure Loss/Inches H2O for Each 10 ft. of Duct Length
250
0.0390.0110.003 0.001—
500
0.1470.0370.013 0.005
0.001
750
0.3210.0790.026 0.011
0.003
1000
0.5570.1400.043 0.018
0.005
1250
0.8550.2100.066 0.027
0.008
1500
— 0.300 0.095 0.0390.012
1750
— 0.380 0.130 0.0530.016
2000
— 0.485 0.155 0.0670.020
2500
—
— 0.245 0.1090.031
3000
———0.145
0.042
4000
———0.240
0.074
5000
——— —
0.120
This diagram details the many components that are needed to complete
a typical fume removal system. All of
these components as well as others are
available from Labconco.
Blower Transition Adapter
(for Coated Steel Blowers only)
Thermoplastic Duct
3-5 duct diameter lengths
(approximately 3-5 feet) between
elbow and blower is required
Intelli-Sense Coated
Steel,Fiberglass or
PVC Blower
Thermoplastic Duct
PVC exhaust duct is Type I, unplasticized, schedule
40, lightweight and corrosion-resistant. A Female Duct
Coupling is required to join two sections. Connections
can be made using solvent cement. PVC is rigid and
may be cut without the use of special tools. Comes in
10' lengths. Flame spread <10.†
Flexible Duct Connection
Thermoplastic Duct*
90° Elbow
Speed
Control Box
Thermoplastic Duct*
Nominal Diameter/Inches Manual Duct Damper
Catalog Number
16-304-10 4718900**16-307-215 16-071-10 5605000**
Actual OD/inches
6.6258.62510.7512.7516.0
Actual ID/inches
6.25 8.25 10.375 12.37515.625
Shipping Weight lbs./kg
25/1135/1650/2365/2980/86
(Highly recommended)
Protector
Laboratory Hood
6
8
10
12
16
®
Duct Couplings, Female
PVC coupling makes connections between two sections
of thermoplastic duct quick and easy.
SpillStopper™ Work Surface
Nominal Diameter/Inches 6
8
10
12
16
Catalog Number
16-304-12 4719200**16-307-218 16-071-13 5605300**
Shipping Weight lbs./kg
4/25/25/26/37/3
Equivalent Resistance in
00000
feet of Straight Duct
Protector Standard,
Acid or Solvent
Storage Cabinet
®
Duct Couplings, Male
PVC duct in 6" lengths facilitates connections between
Blowers and Elbows, Thermoplastic Duct Reducers and
Weathercaps.
*Minimum of 5 to 15 feet of duct in both locations is recommended for noise reduction.
Nominal Diameter/Inches Blower Sizing
6
8
10
12
Catalog Number
2144700**4719900** 16-307-216 16-307-217
Actual OD/inches 6.6258.625 10.75 12.75
Actual ID/inches 6.25 8.25 10.37512.375
Shipping Weight lbs./kg3/1
4/2
5/2
6/3
When sizing a blower, it is necessary to include the equivalent resistance factors
for all the ductwork and accessories in the fume removal system. The diagram
above provides details of the components found in a typical fume removal
system. The “equivalent resistance in feet of straight duct” is provided for each
ductwork component on the pages that follow.
**Contact Fisher Scientific for ordering information.
***Duct made of other materials may require adapters.
† ASTM E-84-09C, modified for round material.
Steps to sizing the right blower.
We can help. Let a Labconco specialist size your blower.
1.Obtain the CFM and static pressure loss for your fume hood (usually located in the fume hood manual or brochure).
2.Add up all the equivalent resistance in feet of straight duct of the components in your system.
3.Use the Static Pressure Losses for Ductwork chart at right to determine the static pressure of your ductwork based on the CFM of your fume hood.
4.Add the static pressure loss of the ductwork to the static pressure loss of your fume hood to determine the total static pressure loss of your fume removal system.
5.Refer to the Optimum Airflow and Static Pressure Ranges (page 3, 4 or 5 depending on the blower) and Blower Performance Curves (back cover) to confirm your blower selection.
6
Ductwork and Accessories
Elbows
Manual Duct Dampers
TM
PVC elbows, both 45º and 90º, are compatible with
thermoplastic duct. Designed and engineered for quick
installation and minimum pressure losses, they feature
belled end connections to receive PVC duct directly.
Nominal Diameter/Inches 6
8
10
12
16
Nominal Diameter/Inches Catalog Number
16-304-11 16-307-200 22-021-474 16-071-11 5605100**
Approx. Height/Inches
13.62517.320.37524.2 29.0
Shipping Weight lbs./kg8/4 10/5 12/5 14/6 17/8
Equivalent Resistance in
1215202536
feet of Straight Duct
Nominal Diameter/Inches 6
8
10
12
10 x 12
Nominal Diameter/ Inches
12 x 16
Nominal Diameter/ Inches
12
13" for use
with 12" fittings
8
10
12
Catalog Number
16-307-20216-307-5316-307-214
Shipping Weight lbs./kg3/1
4/2
4/2
For use with
16-090-11 - 16-090-18 16-090-11 - 16-090-18 16-090-11 - 16-090-18
Labconco Blowers
PVC fittings shaped in T and Y configurations. Compatible with thermoplastic
duct. End connections receive PVC pipe directly. Contact Labconco for help in
sizing blowers with these accessories.
16
Catalog Number
16-304-14 16-307-201B 2
2-021-46916-307-2095622200**
Approx. Height/Inches
3640485672
Shipping Weight lbs./kg20/9 25/11 30/14 35/16 40/18
Equivalent Resistance in
55555
feet of Straight Duct
T’s
Spiral Tube
Y’s
This spiral tube simplifies temporary installations. It is
corrosion-resistant, neoprene-impregnated fiberglass
reinforced with steel wire. Includes rigid duct connector
and two clamps. Length is ten feet.
Nominal Diameter/ Inches
11" for use
with 10" fittings
T and Y Connections
The Zero Pressure Weathercap is made of strong,
corrosion-resistant PVC. The cap adds little static
pressure to the exhaust system and allows for vertical
discharge of the effluent air for dispersion away from
the building.
10
9" for use
with 8" fittings
This epoxy-coated steel transition adapter fits all
Labconco Coated Steel Blowers. This adapter allows you
to connect round thermoplastic duct to the exhaust side
of the blower to create an exhaust stack. Nominal size
PVC duct fits inside the adapter opening.
Zero Pressure Weathercaps
8
16
Blower Transition Adapters
6
12
Catalog Number
4726500**7034200** 5621400**
Shipping Weight lbs./kg5/2
5/2
5/2
Catalog Number
5605900**16-071-14 16-071-15 5630700**
Shipping Weight lbs./kg2/1
5/2
6/3
8/4
Equivalent Resistance in
0000
feet of Straight Duct
Nominal Diameter/Inches 10
This flexible neoprene-impregnated polyester connection reduces vibration between the blower and PVC
ductwork. Supplied with two clamps for easy installation. 12" length.
PVC coupling type reducers are designed for connecting thermoplastic duct of different diameters.
Compare your blower inlet size with your duct size to
see if one is necessary.
8 x 10
8
Flexible Duct Connections
16
Thermoplastic Duct Reducers
6 x 8
6
Catalog Number
10-304-80 4741300**5983400** 5981200**4726400**
Shipping Weight lbs./kg
10/512/515/720/925/11
Approx. Height/inches 14 19.12519.5 19.67 24
Catalog Number
4708800** 4719100** 22-021-478 16-071-12 5605200**
Approx. Height/Inches
8.75 10.7512.5 15 17.5
Shipping Weight lbs./kg8/4 10/5 12/5 14/6 17/8
Equivalent Resistance in
6 7.5 10 12.518
feet of Straight Duct
Nominal Diameter/Inches This damper fitting allows you to balance airflow. It is
highly recommended for use with Intelli-Sense Blowers.
It may be used with exhaust and auxiliary-air ducts, and
is usually placed directly into the fume hood collar.
Nominal Diameter/Inches 10 x 10 x 12 12 x 12 x 12
Catalog Number
5630400** S4633EO**
Shipping Weight lbs./kg20/9 20/9
Approx. Height/inches
1919
Nominal Diameter/Inches 10 x 10 x 12 12 x 12 x 16
Catalog Number
5630100**5630500**
Shipping Weight lbs./kg29/9 20/9
Approx. Height/inches
12.7523.75
Wash Rings
Wash rings are suitable for use in perchloric acid duct
systems. Each features a wide angle conical spray nozzle
and wash water standard PVC connector nipple with
3/4" male threads, fabricated into a PVC female coupling for use with 10" or 12" nominal duct.
7" for use
13" for use
13" for use
13" for use
with 6" fittings with 8" fittings with 10" fittings with 12" fittings
Catalog Number
1965100**4719400** 7027700** 5622300**
Shipping Weight lbs./kg10/5
15/7
20/9
25/11
Equivalent Resistance Because this ductwork is flexible and may conform to various
in feet of Straight Duct configurations, it is not possible to know the precise equivalent resistance.
Nominal Diameter/Inches 10
12
Catalog Number
4746000**16-071-1
Shipping Weight lbs./kg5/2
6/3
**Contact Fisher Scientific for ordering information.
Contact Labconco for ordering information on HEPA Filter Packs, Charcoal
Filter Packs and Backdraft Dampers.
7
Intelli-Sense Multi-Speed Blowers
™
with 10" Diameter Inlet
with 12" Diameter Inlet
TM
2.5
2.25
Performance Curve
Coated Steel Blower with 10" Diameter Inlet
2.25
2
See
Note
1750 RPM
1.5
1500 RPM
Optimum
Blower Performance
1.25
1
See
Note
1250 RPM
0.75
Static Pressure (in. w.g.)
Static Pressure (in. w.g.)
1250 RPM
1.75
1.75
750 RPM
0.25
500 RPM
250
350
450
550
650
1.25
1000 RPM
Optimum
Blower
Performance
1
0.75
750 RPM
750
850
Note: Ambient Temperatures Inside
Motor Housing Greater than 125 °F
May Reduce Maximum Blower
Performance
500 RPM
0.25
Note: Ambient Temperatures
Inside Motor Housing Greater than
125 °F May Reduce Maximum
Blower Performance
0
0
150
1.5
0.5
1000 RPM
0.5
150
950 1050 1150 1250 1350 1450
250
350
450
550
650
750
850
950 1050 1150 1250 1350 1450 1550
Airflow Rate (CFM)
Airflow Rate (CFM)
Intelli-Sense Coated Steel Blowers 16-090-60 & 16-090-61
Intelli-Sense Coated Steel Blowers 16-090-62 & 16-090-63
2.25
2
Performance Curve
Fiberglass or PVC Blower with 10" Diameter Inlet
1.75
Performance Curve
Fiberglass or PVC Blower with 12" Diameter Inlet
2
1500 RPM
1.75
1.5
See Note
Optimum
Blower
Performance
1.25
1800 RPM
1750 RPM
1
1500 RPM
0.75
See
Note
Static Pressure (in. w.g.)
Static Pressure (in. w.g.)
Performance Curve
Coated Steel Blower with
12" Diameter Inlet
2
1.5
1400 RPM
1.25
1300 RPM
1250 RPM
1
Optimum Blower
Performance
0.75
1000 RPM
1250 RPM
0.5
0.5
1000 RPM
Note: Ambient Temperatures
Inside Motor Housing Greater than
125 °F May Reduce Maximum
Blower Performance
0.25
750 RPM
0
750 RPM
500 RPM
500 RPM
150
250
350
450
550
650
750
850
950
Airflow Rate (CFM)
1050 1150 1250 1350
Intelli-Sense Fiberglass Blowers 16-090-64 & 16-090-65
& PVC Blowers 16-090-68 & 16-090-69
Note: Ambient Temperatures Inside
Motor Housing Greater than 125 °F
May Reduce Maximum Blower
Performance
0.25
0
150
250
350
450
550
650
750
850
Intelli-Sense Fiberglass Blowers 16-090-66 & 16-090-67
& PVC Blowers 16-090-70 & 16-090-71
Made in U.S.A.
© 2014 Thermo Fisher Scientific Inc. All rights reserved.
950 1050 1150 1250 1350 1450 1550
Airflow Rate (CFM)
Labconco Corporation
8811 Prospect Avenue
Kansas City, Missouri 64132-2696
800-821-5525 or 816-333-8811
FAX 816-363-0130
www.labconco.com
© 2014 by Labconco Corporation. Printed in the U.S.A.
Product design subject to change without notice.
BN0714144
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF