Savant SST-W100-00 SAVANT WIRELESS THERMOSTAT Quick Reference Guide

Add to my manuals
4 Pages

advertisement

Savant SST-W100-00 SAVANT WIRELESS THERMOSTAT Quick Reference Guide | Manualzz

For Product Info

SST-W100 Wi-Fi Thermostat

Quick Reference Guide

The Savant Wireless Thermostat (SST-W100) is a Wi-Fi® enabled digital thermostat designed to control a Heating, Ventilation and Air

Conditioning (HVAC) system. Use this document as a reference when opening, installing, powering, and connecting to a local wireless network. Once connected, the SST-W100 can join the Savant Control system. For more information on configuring the thermostat, refer to the SST-W100 Deployment Guide (009-0802-xx) and SST-W100

User Guide (009-0957-xx). All documents can be found on the

Savant Customer Community.

Box Contents

(1) SST-W100 Thermostat

(1) Installation Kit

(2) Drywall Anchors

(2) #6 x ¾ in self tapping screws

(1) Wire Labels (Sheet of wire label stickers)

(1) Quick Reference Guide (this document)

Optional Components

SST-TEMP1-xx - Remote Indoor Temperature Sensor

SST-OTEMP1-xx - Remote Outdoor Temperature Sensor

Specifications

Temperature

Humidity

Height

Width

Depth

32° to 104° F (0° to 40° C)

10% to 90% Relative Humidity (non-condensing)

3.96 in (10.06 cm)

5.775 in (14.67 cm)

0.58 in (1.47 cm)

Net - 0.5 lb (0.23 kg)

Shipping - 2.0 lb (0.91 kg)

24V AC (19V AC - 28V AC)

Connect to terminals 24C and 24RH on terminal block on back panel.

Requires both R and C from the HVAC system.

Max. current draw 200 mA

Power

HVAC

Remote Sensors

#18 AWG

#18 AWG Thermostat Wire (solid)

#24 AWG (Cat 5) 500 feet (152 m) maximum

Safety and

Emissions

RoHS

Wireless

Security

FCC Part 15 | UL Class 2

For more details, refer to the Regulatory section

Compliant

Wi-Fi (802.11 b/g)

WPA1™, WPA2™, WPA1™ + WPA2™ panel. Each terminal is marked. Refer to table for a description of each terminal.

Savant OS da Vinci 5.2

Front View

Each of the buttons are multipurpose buttons. The function of each button changes depending on the screen currently displayed. The information below describes the main screen shown above.

The Outside temperature displayed is retrieved from the remote sensor RS2 when configured as an outdoor sensor.

Displays local time. The time is set through the MENU button.

The status of the HVAC system is displayed here. From the image above:

• Sys Off - HVAC system is Off.

• Fan Off - Fan is Off.

• Link OK - Connected to a local Wi-Fi® network.

The temperature displayed is the local indoor temperature.

G

H

I

J

Pressing the MENU button for the first time opens the SET

CLOCK menu. Once the clock is set, pressing the MENU button will open the main menu.

MODE button selects Off, Heating, Cooling, or Auto.

Heat Mode controls a heating system, Cool Mode controls a cooling system, and AUTO Mode controls both.

The relative humidity displayed is retrieved from a humidity sensor that is internal to the SST-W100.

The high and low setpoints are displayed. To modify each, press the up/down arrow button to the right of each setpoint.

The up/down arrow buttons are multipurpose buttons. In the screen shown, pressing the up or down arrow button will open the high and low setpoint windows. In other windows, the buttons are used to move up and down a list of items.

Fan Mode can be changed between On, Auto, and Cycle.

Select the correct mode for your HVAC system.

K Used in various screens for different functions.

Copyright © 2016 Savant Systems, LLC 1 of 4

45 Perseverance Way, Hyannis, MA 02601

Savant.com

| 508.683.2500

Rear Panel

Mounting Slots - The SST-W100 comes with wall anchors and screws to mount to an existing wall. Place the back panel on the wall and mark where the wall anchors are to be installed.

Terminal Blocks - All wiring is connected to one of the two terminal blocks. Refer to table below for a brief description of each position.

Wire Slot - This rectangular slot is where the wires coming from the HVAC system and/or remote sensors are fed into the thermostat.

Terminal Block Connections

24RC

G

Y1

Y2

RS2

RS2

RSC

A1

Connect the 24V AC hot wire from the transformer on HVAC system to the 24RC terminal. When there is a separate heating and cooling system, the wire from the transformer on the cooling system is wired here. **See Note below.

Connect to the fan terminal on the HVAC system.

Connect to the 1st stage cooling terminal on the HVAC system

Connect to the 2nd stage cooling terminal on the HVAC system

Remote Sensor 2 - Connect to remote temperature sensor RS2.

No polarity is observed.

Remote Sensor 2 - Connect to remote temperature sensor RS2.

No polarity is observed.

If there is a shield on the cable that connects to remote sensor

RS2, connect that shield to the RSC terminal.

• Auxiliary Relay 1 can turn external equipment such as a humidifier, dehumidifier, and external vent damper on and off.

• Auxiliary Relay 1 can be turned on and off according to workflows and triggers set up in RacePoint Blueprint.

• Can also be used to control the speed of an external dehumidification fan when using an air handler for dehumidification.

24C

24RH

W1

W2/O

RS1

RS1

RSC

A2

Connect the common wire from the transformer on HVAC system to the 24C terminal. When there is a separate heating and cooling system transformer, the common wire from the cooling system is wired here.

When there is a separate heating and cooling system, the wire from the transformer on the heating system is wired here. **See

Note below.

Connect to 1st stage heating terminal on the HVAC system.

Connect to 2nd stage heating terminal on the HVAC system. If the system is a Heat Pump type system, connect to the changeover terminal (O).

Remote Sensor 1 - Connect to remote temperature sensor RS1.

No polarity is observed.

Remote Sensor 1 - Connect to remote temperature sensor RS1.

No polarity is observed.

If there is a shield on the cable that connects to remote sensor

RS1, connect that shield to the RSC terminal.

• Auxiliary Relay 2 can turn external equipment such as a humidifier, dehumidifier and external vent damper on and off.

• Auxiliary Relay 1 can be turned on and off according to workflows and triggers set up in RacePoint Blueprint.

** Note: When connecting power to the thermostat, if there are separate transformers for cooling and heating, the transformer from the cooling system is wired to the 24RC terminal and the transformer from the heating system is wired to the 24RH terminal. In this scenario, jumper JP1 located on the

PCB circuit board must be cut to separate the 24RH and 24RC terminals. Failure to cut this jumper could result is damage to the circuit board when powering the system.

Install Thermostat

The SST-W100 can be mounted to an existing wall. Position the thermostat on an interior wall that is away from direct sunlight or any heating ducts or radiators. If replacing an existing thermostat, prior to removing the old thermostat, switch off power to the heating and/or cooling system. During the removal process, it is good practice to label each wire removed with the reference designator marked on the old thermostat being removed. Follow the instructions below to install the SST-W100 thermostat.

1.

Separate the thermostat from its rear mounting plate by grasping the top and bottom of the rear mounting plate in one hand and top and bottom of the thermostat in the other hand. Pull halves apart by rocking the top and bottom of each half until they separate.

2.

Position the rear mounting plate onto the wall where the thermostat will be located. Verify that writing next to each 8-position terminal block can be read. If not, the rear panel is upside down.

3.

With a pencil, mark the two slots in the rear mounting plate onto the wall.

4.

Drill a ¼ inch hole on each mark.

5.

Insert the wall anchor into the holes drilled and using a #2 screwdriver rotate the anchor into the wall using a gentle forward pressure until the anchor is flush with wall.

6.

Place the thermostat base onto the wall. Pull the wires out through the center cutout located between the two terminal blocks. Screw the rear mounting plate to the wall using the #6 x ¾ in self tapping screws supplied.

Copyright © 2016 Savant Systems, LLC 2 of 4

45 Perseverance Way, Hyannis, MA 02601

Savant.com

| 508.683.2500

Wiring Diagrams

The wiring diagrams below display a few wiring configurations. For additional wiring diagrams, refer to the SST-W100 Wireless Thermostat Deployment

Guide (009-0802-xx) on the Savant Customer Community.

Standard Gas/Electric One Stage Heating/Cooling Standard Gas/Electric Two Stage Heating/Cooling

Heat Pump Single Stage Heat Pump Two Stage

Copyright © 2016 Savant Systems, LLC 3 of 4

45 Perseverance Way, Hyannis, MA 02601

Savant.com

| 508.683.2500

Remote Sensors

The SST-W100 supports connecting up to two remote temperature sensors (SST-TEMP1 and/or SST-OTEMP1). These sensors are wired to the SST-W100 using #24 AWG cable. The table below displays the configurations supported through software. Refer to the SST-W100 Wireless Thermostat

Deployment Guide (009-0802-xx) when connecting each of the sensors.

Sensor Descriptions

Internal Sensor - The thermostat has an internal temperature sensor mounted on the PCB circuit board.

RS1 (Remote Sensor 1) - RS1 is hardwired to the terminal block on back panel and is typically mounted in a location away from the thermostat. The

RS1 connection is for internal/indoor (SST-TEMP1) use only and when attached, this disables the internal sensor. RS1 cannot be configured for outdoor use.

RS2 (Remote Sensor 2) - This sensor is hardwired to the terminal block on back panel of the SST-W100 and can be used as either an internal/indoor

(SST-TEMP1) or external/outdoor (SST-OTEMP1) sensor.

Connect to a Local Wireless Network

The SST-W100 integrates into the Savant Control system through the local wireless network. The SST-W100 can connect to a wireless network using a few different methods. The information below describes how to join a wireless network using the SSID of the network. The remaining methods are described in the SST-W100 Wireless Thermostat Deployment Guide (009-0802-xx). Click the link in

Additional Information

section below.

1.

Press any button on front panel of the SST-W100 to light up LCD for viewing.

2.

Press the MENU button from the lower left side of the display.

3.

From the Menu Selection screen, scroll to the Wi-Fi Setup selection using the arrow buttons.

4.

Press Select to open the Wi-Fi Setup menu.

5.

Scroll to the SSID selection and press Select. A Wi-Fi Networks menu appears.

6.

Scroll to the local Wi-Fi network where the SST-W100 will be connected. Press the Join button to join this network.

7.

If this network is secured, enter the passphrase for the network.

• The up/down buttons scroll through the upper and lowercase letters, numbers, and special characters.

• The < > arrows on the LCD display move to the next character in the passphrase.

Refer to the table of supported SSID Guidelines

section below.

8.

Select Done once the passphrase has been entered. The SST-W100 will connect to the Wi-Fi network. A Wi-Fi Network Status screen will open displaying the connection information.

9.

The SST-W100 is now connected to the local wireless network. Select Done to exit the Wi-Fi Network Status screen.

10.

Select Done to exit the Menu Selection screen.

SSID Guidelines

Savant Wi-Fi products can connect to Wi-Fi networks that meet the following SSID guidelines:

Maximum SSID Length:

32 characters - Firmware 2.13.00 or later

16 characters - Firmware prior to 2.13.00

Maximum Passphrase Length:

WPA/WPA2: 8-63 characters

WEP: 10-26 characters

For a list of supported characters, refer to remote sensor section of the SST-W100 Wireless Thermostat Deployment Guide (009-0802-xx).

Additional Information

For additional information on how to program the SST-W100, refer to the following documents which can be found on the Savant Customer

Community.

Savant Store > Climate > Thermostats

• SST-W100 Wireless Thermostat Deployment Guide (009-0802-xx)

• Savant Wireless Thermostat User Guide (009-0957-xx)

Regulatory

The following statements are applicable to the SST-W100:

This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Any changes or modifications of this product, not approved by manufacturer will void the user’s authority to operate the equipment.

This device complies with Industry Canada license-exempt RSS standard(s). Operation is subject to the following two conditions: (1) this device may not cause interference, and (2) this device must accept any interference, including interference that may cause undesired operation of the device.

Le présent appareil est conforme aux CNR d'Industrie Canada applicables aux appareils radio exempts de licence. L'exploitation est autorisée aux deux conditions suivantes: (1) l'appareil ne doit pas produire de brouillage, et (2) l'utilisateur de l'appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est susceptible d'en compromettre le fonctionnement.

Copyright © 2016 Savant Systems, LLC 4 of 4

45 Perseverance Way, Hyannis, MA 02601

Savant.com

| 508.683.2500

advertisement

Was this manual useful for you? Yes No
Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project

Related manuals

Download PDF

advertisement