Storwize V3700: Quick Installation Guide

Storwize V3700: Quick Installation Guide
IBM Storwize V3700
Quick Installation Guide
GC27-4219-01
Note
Before using this information and the product it supports, read the general information in “Notices” on page 53, the
information in the “Safety and environmental notices” on page ix, as well as the information in the IBM Environmental
Notices and User Guide , which is provided on a DVD.
This edition applies to IBM Storwize V3700 and is valid until replaced by new editions.
© Copyright IBM Corporation 2012, 2013.
US Government Users Restricted Rights – Use, duplication or disclosure restricted by GSA ADP Schedule Contract
with IBM Corp.
Contents
Figures . . . . . . . . . . . . . . . v
Connecting Ethernet cables for system management 36
1 Connecting Ethernet cables to 1 Gbps iSCSI 4-port
Tables . . . . . . . . . . . . . . . vii
Safety and environmental notices . . . ix
Safety notices and labels . . . . . . . . . . ix
Caution notices for the Storwize V3700 . . . . x
Danger notices for Storwize V3700 . . . . . xii
Special caution and safety notices. . . . . . . xiv
General safety . . . . . . . . . . . . xiv
Handling static-sensitive devices . . . . . . xv
Environmental notices . . . . . . . . . . xvi
About this guide . . . . . . . . . . xvii
Who should use this guide. . . . . . . .
Storwize V3700 library and related publications
How to order IBM publications . . . . . .
Related websites . . . . . . . . . . .
Sending your comments . . . . . . . . .
How to get information, help, and technical
assistance . . . . . . . . . . . . . .
What's new . . . . . . . . . . . . .
. xvii
xvii
. xix
. xix
. xix
. xx
. xxii
Chapter 1. Before you begin the
installation . . . . . . . . . . . . . 1
Reviewing your packing slip . . . . . . . . . 5
Identifying the hardware components . . . . . . 6
Verifying environmental requirements . . . . . 10
Reviewing enclosure location guidelines . . . . . 10
Chapter 2. Installing the hardware . . . 11
1
1
1
1
Installing the support rails . . . . . . . .
Installing the enclosures . . . . . . . . .
Installing options in the control enclosure . . .
Opening the node canister . . . . . . .
Installing an 8 Gbps Fibre Channel 4-port host
interface card . . . . . . . . . . . .
Installing a 10 Gbps iSCSI-FCoE 2-port host
interface card . . . . . . . . . . . .
Installing a 1 Gbps iSCSI 4-port host interface
card . . . . . . . . . . . . . . .
Installing a SAS 4-port host interface card . .
Installing an 8 GB cache memory upgrade . .
Closing the node canister . . . . . . . .
Installing disk drives . . . . . . . . . .
Connecting SAS cables to expansion enclosures .
© Copyright IBM Corp. 2012, 2013
.
.
.
.
11
16
17
18
. 20
. 22
.
.
.
.
.
.
24
26
27
30
32
33
host interface cards .
.
.
.
.
.
.
.
.
.
.
. 36
.
. 37
1 Connecting fibre cables to a 10 Gbps iSCSI-FCoE
2-port host interface card .
.
.
.
.
.
.
.
1 Connecting Fibre Channel cables to an 8 Gbps Fibre
Channel 4-port host interface card .
.
.
.
.
.
. 39
1 Connecting SAS cables to a host . . . . . . . 39
Powering on the system .
.
.
.
.
.
.
.
.
. 42
Chapter 3. Configuring the system . . . 45
1
1
1
1
1
Web browser requirements to access the
management GUI . . . . . . . . . . .
User name and password for system initialization
Initializing the system with a Microsoft Windows
computer . . . . . . . . . . . . . .
Initializing the system with an Apple Macintosh
computer . . . . . . . . . . . . . .
Initializing the system with a Linux computer . .
Adding an expansion enclosure to an existing
system . . . . . . . . . . . . . . .
. 45
46
. 47
. 49
. 51
. 52
Notices . . . . . . . . . . . . . . 53
Trademarks . . . . . . . . . . . . . .
Electronic emission notices . . . . . . . . .
Federal Communications Commission (FCC)
statement . . . . . . . . . . . . . .
Industry Canada compliance statement . . . .
Australia and New Zealand Class A Statement
European Union Electromagnetic Compatibility
Directive . . . . . . . . . . . . . .
Germany Electromagnetic Compatibility Directive
People's Republic of China Class A Statement . .
Taiwan Class A compliance statement . . . .
Taiwan Contact Information . . . . . . . .
Japan VCCI Council Class A statement . . . .
Japan Electronics and Information Technology
Industries Association Statement . . . . . .
Korean Communications Commission Class A
Statement . . . . . . . . . . . . . .
Russia Electromagnetic Interference Class A
Statement . . . . . . . . . . . . . .
European Contact Information . . . . . . . .
Taiwan Contact Information . . . . . . . . .
55
55
55
56
56
56
56
57
58
58
58
58
59
59
59
59
Index . . . . . . . . . . . . . . . 61
iii
iv
Storwize V3700: Quick Installation Guide
Figures
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
11.
12.
13.
14.
1 15.
1 16.
1 17.
1 18.
19.
20.
Rear view of a Storwize V3700 control enclosure 6
Data ports in the rear of the control enclosure
7
Rear view of a Storwize V3700 expansion
enclosure. . . . . . . . . . . . . . 8
SAS ports and LEDs in rear of expansion
canister . . . . . . . . . . . . . . 8
USB flash drive . . . . . . . . . . . 8
Rack mounting rails and screws. . . . . . 11
Installing the rail spring . . . . . . . . 12
Hole locations in the front of the rack . . . . 13
Opening the hinge brackets . . . . . . . 14
Closing hinge brackets and installing rear
screw . . . . . . . . . . . . . . 15
Inserting the enclosure . . . . . . . . . 16
Removing a node canister. . . . . . . . 18
Removing the canister cover . . . . . . . 19
Host interface card and SFP transceivers
20
Installing 8 Gbps Fibre Channel 4-port host
interface card . . . . . . . . . . . . 21
Installing 10 Gbps iSCSI-FCoE 2 port host
interface card . . . . . . . . . . . . 23
Installing 1 Gbps iSCSI 4-port host interface
card . . . . . . . . . . . . . . . 25
Installing SAS 4-port host interface card
26
Where to install the cache memory upgrade
28
Installing memory module option . . . . . 29
© Copyright IBM Corp. 2012, 2013
21.
22.
23.
24.
25.
26.
27.
1 28.
1
1
1 29.
1
1
30.
31.
1
1
1
1
1
1
32.
33.
34.
35.
36.
37.
Reinstalling the canister cover . . . . . .
Installing a node canister . . . . . . . .
Removing a filler panel . . . . . . . .
Installing a drive . . . . . . . . . . .
SAS cable connectors . . . . . . . . .
Connecting the SAS cables . . . . . . .
Connecting the Ethernet cables . . . . . .
Example configuration with two pairs of
Ethernet cables connected to 1 Gbps iSCSI
4-port host interface cards. . . . . . . .
Example configuration with two pairs of
Ethernet cables connected to 10 Gbps
iSCSI-FCoE 2-port host interface cards . . .
Example configuration with two Fibre Channel
cables per canister . . . . . . . . . .
Example configuration with four Fibre
Channel cables per canister . . . . . . .
Mini SAS HD to Mini SAS HD cable . . . .
Mini SAS HD to Mini SAS cable . . . . .
Example configuration with three SAS cables
per canister . . . . . . . . . . . .
Example configuration with two SAS cables
connected to a SAS 4-port host interface card .
Expansion canister LEDs . . . . . . . .
Node canister LEDs . . . . . . . . . .
30
31
32
33
34
35
36
37
38
39
39
40
40
41
41
42
43
v
vi
Storwize V3700: Quick Installation Guide
Tables
1.
2.
3.
4.
IBM websites for help, services, and
information . . . . . . . . . . . . xvii
Storwize V3700 library . . . . . . . . xviii
IBM documentation and related websites
xix
IBM websites for help, services, and
information . . . . . . . . . . . . xx
© Copyright IBM Corp. 2012, 2013
1 5.
6.
7.
Steps for different installation scenarios . . . 1
Storwize V3700 model numbers . . . . . . 5
Default user name and password for the
management GUI . . . . . . . . . . 46
vii
viii
Storwize V3700: Quick Installation Guide
Safety and environmental notices
Review the safety notices, environmental notices, and electronic emission notices
for IBM® Storwize® V3700 before you install and use the product.
Here are examples of a caution and a danger notice:
CAUTION:
A caution notice indicates the presence of a hazard that has the potential of
causing moderate or minor personal injury. (C001)
DANGER
A danger notice indicates the presence of a hazard that has the potential of
causing death or serious personal injury. (D002)
1
1
To find the translated text for a caution or danger notice:
1. Look for the identification number at the end of each caution notice or each
danger notice. In the preceeding examples, the numbers (C001) and (D002) are
the identification numbers.
2. Locate IBM Systems Safety Notices with the user publications that were provided
with the Storwize V3700 hardware.
3. Find the matching identification number in the IBM Systems Safety Notices. Then
review the topics concerning the safety notices to ensure that you are in
compliance.
4. Optionally, read the multilingual safety instructions on the Storwize V3700
website. Go to www.ibm.com/storage/support/storwize/v3700 and click the
documentation link.
Safety notices and labels
Review the safety notices and safety information labels before using this product.
To view a PDF file, you need Adobe Acrobat Reader. You can download it at no
charge from the Adobe website:
www.adobe.com/support/downloads/main.html
IBM Systems Safety Notices
This publication contains the safety notices for the IBM Systems products in
English and other languages. Anyone who plans, installs, operates, or services the
system must be familiar with and understand the safety notices. Read the related
safety notices before you begin work.
Note: The IBM Systems Safety Notices document is organized into two sections.
The danger and caution notices without labels are organized alphabetically by
language in the “Danger and caution notices by language” section. The danger and
caution notices that are accompanied with a label are organized by label reference
number in the “Labels” section.
© Copyright IBM Corp. 2012, 2013
ix
The following notices and statements are used in IBM documents. They are listed
in order of decreasing severity of potential hazards.
Danger notice definition
A special note that emphasize a situation that is potentially lethal or
extremely hazardous to people.
Caution notice definition
A special note that emphasize a situation that is potentially hazardous to
people because of some existing condition, or to a potentially dangerous
situation that might develop because of some unsafe practice.
Note: In addition to these notices, labels might be attached to the product to warn
of potential hazards.
Finding translated notices
Each safety notice contains an identification number. You can use this identification
number to check the safety notice in each language.
To find the translated text for a caution or danger notice:
1. In the product documentation, look for the identification number at the end of
each caution notice or each danger notice. In the following examples, the
numbers (D002) and (C001) are the identification numbers.
DANGER
A danger notice indicates the presence of a hazard that has the potential
of causing death or serious personal injury. (D002)
CAUTION:
A caution notice indicates the presence of a hazard that has the potential of
causing moderate or minor personal injury. (C001)
2. Open the IBM Systems Safety Notices.
3. Under the language, find the matching identification number. Review the topics
about the safety notices to ensure that you are in compliance.
Note: This product was designed, tested, and manufactured to comply with IEC
60950-1, and where required, to relevant national standards that are based on IEC
60950-1.
Caution notices for the Storwize V3700
Ensure that you understand the caution notices for Storwize V3700.
Use the reference numbers in parentheses at the end of each notice, such as (C003)
for example, to find the matching translated notice in IBM Systems Safety Notices.
18-32 kg (39.7-70.5 lbs)
(27)
x
Storwize V3700: Quick Installation Guide
32-55 kg (70.5-121.2 lbs)
55 kg ( 121.2 lbs)
svc00146
CAUTION:
Use safe practices when lifting.
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
CAUTION:
Removing components from the upper positions in the rack cabinet improves
rack stability during a relocation. Follow these general guidelines whenever you
relocate a populated rack cabinet within a room or building.
v Reduce the weight of the rack cabinet by removing equipment starting at the
top of the rack cabinet. When possible, restore the rack cabinet to the
configuration of the rack cabinet as you received it. If this configuration is not
known, you must observe the following precautions.
– Remove all devices in the 32U position and above.
–
Ensure that the heaviest devices are installed in the bottom of the rack
cabinet.
– Ensure that there are no empty U-levels between devices installed in the
rack cabinet below the 32U level.
v If the rack cabinet you are relocating is part of a suite of rack cabinets, detach
the rack cabinet from the suite.
v If the rack cabinet you are relocating was supplied with removable outriggers
they must be reinstalled before the cabinet is relocated.
v Inspect the route that you plan to take to eliminate potential hazards.
v Verify that the route that you choose can support the weight of the loaded
rack cabinet. Refer to the documentation that comes with your rack cabinet for
the weight of a loaded rack cabinet.
v Verify that all door openings are at least 760 x 230 mm (30 x 80 in.).
1
1
1
1
1
1
v Ensure that all devices, shelves, drawers, doors, and cables are secure.
v Ensure that the four leveling pads are raised to their highest position.
v Ensure that there is no stabilizer bracket installed on the rack cabinet during
movement.
v Do not use a ramp inclined at more than 10 degrees.
v When the rack cabinet is in the new location, complete the following steps:
– Lower the four leveling pads.
– Install stabilizer brackets on the rack cabinet.
– If you removed any devices from the rack cabinet, repopulate the rack
cabinet from the lowest position to the highest position.
v If a long-distance relocation is required, restore the rack cabinet to the
configuration of the rack cabinet as you received it. Pack the rack cabinet in
the original packaging material, or equivalent. Also lower the leveling pads to
raise the casters off the pallet and bolt the rack cabinet to the pallet.
1
(R002)
1
1
1
1
1
1
1
CAUTION:
1
1
1
1
v Rack is not intended to serve as an enclosure and does not provide any
degrees of protection required of enclosures.
v It is intended that equipment installed within this rack will have its own
enclosure. (R005).
1
CAUTION:
Tighten the stabilizer brackets until they are flush against the rack. (R006)
1
CAUTION:
Use safe practices when lifting. (R007)
Safety and environmental notices
xi
1
1
CAUTION:
Do not place any object on top of a rack-mounted device unless that
rack-mounted device is intended for use as a shelf. (R008)
1
1
CAUTION:
If the rack is designed to be coupled to another rack only the same model rack
should be coupled together with another same model rack. (R009)
Danger notices for Storwize V3700
Ensure that you are familiar with the danger notices for Storwize V3700.
Use the reference numbers in parentheses at the end of each notice, such as (C003)
for example, to find the matching translated notice in IBM Systems Safety Notices.
xii
Storwize V3700: Quick Installation Guide
DANGER
When working on or around the system, observe the following precautions:
Electrical voltage and current from power, telephone, and communication
cables are hazardous. To avoid a shock hazard:
v If IBM supplied a power cord(s), connect power to this unit only with the
IBM provided power cord. Do not use the IBM provided power cord for
any other product.
v Do not open or service any power supply assembly.
v Do not connect or disconnect any cables or perform installation,
maintenance, or reconfiguration of this product during an electrical storm.
v The product might be equipped with multiple power cords. To remove all
hazardous voltages, disconnect all power cords.
v Connect all power cords to a properly wired and grounded electrical outlet.
Ensure that the outlet supplies proper voltage and phase rotation according
to the system rating plate.
v Connect any equipment that will be attached to this product to properly
wired outlets.
v When possible, use one hand only to connect or disconnect signal cables.
v Never turn on any equipment when there is evidence of fire, water, or
structural damage.
v Disconnect the attached power cords, telecommunications systems,
networks, and modems before you open the device covers, unless
instructed otherwise in the installation and configuration procedures.
v Connect and disconnect cables as described in the following procedures
when installing, moving, or opening covers on this product or attached
devices.
To disconnect:
1. Turn off everything (unless instructed otherwise).
2. Remove the power cords from the outlets.
3.
4.
To
1.
2.
Remove the signal cables from the connectors.
Remove all cables from the devices.
connect:
Turn off everything (unless instructed otherwise).
Attach all cables to the devices.
3. Attach the signal cables to the connectors.
4. Attach the power cords to the outlets.
5. Turn on the devices.
v Sharp edges, corners and joints may be present in and around the system.
Use care when handling equipment to avoid cuts, scrapes and pinching.
(D005)
DANGER
Heavy equipment–personal injury or equipment damage might result if
mishandled. (D006)
DANGER
Safety and environmental notices
xiii
Racks with a total weight of > 227 kg (500 lb.), Use Only Professional Movers!
(R003)
1
1
DANGER
Do not transport the rack via fork truck unless it is properly packaged,
secured on top of the supplied pallet. (R004)
1
1
DANGER
1
1
1
1
Main Protective Earth (Ground):
1
This symbol is marked on the frame of the rack.
1
1
1
1
1
1
1
1
1
1
1
1
The PROTECTIVE EARTHING CONDUCTORS should be terminated at that
point. A recognized or certified closed loop connector (ring terminal) should
be used and secured to the frame with a lock washer using a bolt or stud.
The connector should be properly sized to be suitable for the bold or stud,
the locking washer, the rating for the conducting wire used, and the
considered rating of the breaker. The intent is to ensure the frame is
electrically bonded to the PROTECTIVE EARTHING CONDUCTORS. The
hole that the bolt or stud goes into where the terminal conductor and the lock
washer contact should be free of any non-conductive material to allow for
metal to metal contact. All PROTECTIVE EARTHING CONDUCTORS
should terminate at this main protective earthing terminal or at points
. (R010)
marked with
Special caution and safety notices
This information describes special safety notices that apply to the Storwize V3700.
These notices are in addition to the standard safety notices supplied and address
specific issues relevant to the equipment provided.
General safety
When you service the Storwize V3700, follow general safety guidelines.
Use the following general rules to ensure safety to yourself and others:
v Observe good housekeeping in the area where the devices are kept during and
after maintenance.
v Follow the guidelines when lifting any heavy object:
1. Ensure that you can stand safely without slipping.
2. Distribute the weight of the object equally between your feet.
3. Use a slow lifting force. Never move suddenly or twist when you attempt to
lift.
4. Lift by standing or by pushing up with your leg muscles; this action removes
the strain from the muscles in your back. Do not attempt to lift any objects that
weigh more than 18 kg (40 lb) or objects that you think are too heavy for you.
xiv
Storwize V3700: Quick Installation Guide
v Do not perform any action that causes a hazard or that makes the equipment
unsafe.
v Before you start the device, ensure that other personnel are not in a hazardous
position.
v Place removed covers and other parts in a safe place, away from all personnel,
while you are servicing the unit.
v Keep your tool case away from walk areas so that other people will not trip over
it.
v Do not wear loose clothing that can be trapped in the moving parts of a device.
Ensure that your sleeves are fastened or rolled up above your elbows. If your
hair is long, fasten it.
v Insert the ends of your necktie or scarf inside clothing or fasten it with a
nonconducting clip, approximately 8 cm (3 in.) from the end.
v Do not wear jewelry, chains, metal-frame eyeglasses, or metal fasteners for your
clothing.
Remember: Metal objects are good electrical conductors.
v Wear safety glasses when you are: hammering, drilling, soldering, cutting wire,
attaching springs, using solvents, or working in any other conditions that might
be hazardous to your eyes.
v After service, reinstall all safety shields, guards, labels, and ground wires.
Replace any safety device that is worn or defective.
v Reinstall all covers correctly after you have finished servicing the unit.
Handling static-sensitive devices
Ensure that you understand how to handle devices that are sensitive to static
electricity.
Attention: Static electricity can damage electronic devices and your system. To
avoid damage, keep static-sensitive devices in their static-protective bags until you
are ready to install them.
To reduce the possibility of electrostatic discharge, observe the following
precautions:
v Limit your movement. Movement can cause static electricity to build up around
you.
v Handle the device carefully, holding it by its edges or frame.
v Do not touch solder joints, pins, or exposed printed circuitry.
v Do not leave the device where others can handle and possibly damage the
device.
v While the device is still in its antistatic bag, touch it to an unpainted metal part
of the system unit for at least two seconds. (This action removes static electricity
from the package and from your body.)
v Remove the device from its package and install it directly into your Storwize
V3700, without putting it down. If it is necessary to put the device down, place
it onto its static-protective bag. (If your device is an adapter, place it
component-side up.) Do not place the device onto the cover of the Storwize
V3700 or onto a metal table.
v Take additional care when you handle devices during cold weather because
heating reduces indoor humidity and increases static electricity.
Safety and environmental notices
xv
Environmental notices
This publication contains all the required environmental notices for IBM Systems
products in English and other languages.
The IBM Systems Environmental Notices and User Guide (ftp://
public.dhe.ibm.com/systems/support/warranty/envnotices/
environmental_notices_and_user_guide.pdf), Z125-5823 document includes
statements on limitations, product information, product recycling and disposal,
battery information, flat panel display, refrigeration, and water-cooling systems,
external power supplies, and safety data sheets.
To view a PDF file, you need Adobe Reader. You can download it at no charge
from the Adobe web site (get.adobe.com/reader/).
xvi
Storwize V3700: Quick Installation Guide
About this guide
This publication provides information that helps you install and initialize IBM
Storwize V3700.
Who should use this guide
This guide is intended for installers of Storwize V3700.
Before configuring your system, ensure that you follow the procedures as listed. Be
sure to gather IP addresses that you will need before you begin the installation.
Storwize V3700 library and related publications
Product manuals, other publications, and websites contain information that relates
to Storwize V3700.
Storwize V3700 Information Center
The IBM Storwize V3700 Information Center contains all of the information that is
required to install, configure, and manage the Storwize V3700. The information
center is updated between Storwize V3700 product releases to provide the most
current documentation. The information center is available at the following
website:
pic.dhe.ibm.com/infocenter/storwize/v3700_ic/index.jsp
Storwize V3700 library
Unless otherwise noted, the publications in the Storwize V3700 library are
available in Adobe portable document format (PDF) from the following website:
www.ibm.com/e-business/linkweb/publications/servlet/pbi.wss
The following table lists websites where you can find help, services, and more
information:
Table 1. IBM websites for help, services, and information
Website
Address
Directory of worldwide contacts
http://www.ibm.com/planetwide
Support for Storwize V3700 (2072)
Support for IBM System Storage
and IBM TotalStorage products
®
www.ibm.com/storage/support/storwize/v3700
www.ibm.com/storage/support/
Each of the PDF publications in the Table 2 on page xviii is also available in the
information center by clicking the number in the “Order number” column:
© Copyright IBM Corp. 2012, 2013
xvii
Table 2. Storwize V3700 library
Title
Description
Order number
IBM Storwize V3700 Quick
Installation Guide
GC27-4219
This guide provides
instructions for unpacking
your shipping order and
installing your system. The
first of three chapters
describes verifying your
order, becoming familiar
with the hardware
components, and meeting
environmental requirements.
The second chapter describes
installing the hardware and
attaching data cables and
power cords. The last
chapter describes accessing
the management GUI to
initially configure your
system.
IBM Systems Safety Notices
This guide contains
translated caution and
danger statements. Each
caution and danger
statement in the Storwize
V3700 documentation has a
number that you can use to
locate the corresponding
statement in your language
in the IBM Systems Safety
Notices document.
G229-9054
IBM Storwize V3700 Read
First Flyer
This document introduces
the major components of the
Storwize V3700 system and
describes how to get started
with the IBM Storwize V3700
Quick Installation Guide.
Part number: 00Y2619
IBM Statement of Limited
Warranty (2072)
This multilingual document
provides information about
the IBM warranty for
machine type 2072.
Part number: 00Y2617
IBM License Agreement for
Machine Code
This multilingual guide
contains the License
Agreement for Machine
Code for the Storwize V3700
product.
SC28-6872 (contains
Z125-5468)
IBM documentation and related websites
Table 3 on page xix lists websites that provide publications and other information
about the Storwize V3700 or related products or technologies.
xviii
Storwize V3700: Quick Installation Guide
Table 3. IBM documentation and related websites
Website
Address
IBM Storage Management Console for
VMware vCenter
The IBM Storage Host Software Solutions
Information Center describes how to install,
configure, and use the IBM Storage Management
Console for VMware vCenter, which enables Storwize
V3700 and other IBM storage systems to be
integrated in VMware vCenter environments.
IBM Publications Center
www.ibm.com/e-business/linkweb/publications/
servlet/pbi.wss
IBM Redbooks® publications
www.redbooks.ibm.com/
Related accessibility information
To view a PDF file, you need Adobe Acrobat Reader, which can be downloaded
from the Adobe website:
www.adobe.com/support/downloads/main.html
How to order IBM publications
The IBM Publications Center is a worldwide central repository for IBM product
publications and marketing material.
The IBM Publications Center offers customized search functions to help you find
the publications that you need. Some publications are available for you to view or
download at no charge. You can also order publications. The publications center
displays prices in your local currency. You can access the IBM Publications Center
through the following website:
www.ibm.com/e-business/linkweb/publications/servlet/pbi.wss
Related websites
The following websites provide information about Storwize V3700 or related
products or technologies:
Type of information
Website
Storwize V3700 support
www.ibm.com/storage/support/storwize/v3700
Technical support for IBM
storage products
www.ibm.com/storage/support/
IBM Electronic Support
registration
www.ibm.com/support/electronicsupport
Sending your comments
Your feedback is important in helping to provide the most accurate and highest
quality information.
To submit any comments about this book or any other Storwize V3700
documentation:
About this guide
xix
v Go to the feedback form on the website for the Storwize V3700 Information
Center at pic.dhe.ibm.com/infocenter/storwize/v3700_ic/index.jsp?topic=/
com.ibm.storwize.v3700.doc/feedback_v3700.htm. You can use the form to enter
and submit comments. You can browse to the topic in question and use the
feedback link at the very bottom of the page to automatically identify the topic
for which you have a comment.
v Send your comments by email to starpubs@us.ibm.com. Include the following
information in your email:
– Publication title
– Publication form number
– Page, table, or illustration numbers that you are commenting on
– A detailed description of any information that should be changed
How to get information, help, and technical assistance
If you need help, service, technical assistance, or just want more information about
IBM products, you will find a wide variety of sources available from IBM to assist
you.
Information
IBM maintains pages on the web where you can get information about IBM
products and fee services, product implementation and usage assistance, break and
fix service support, and the latest technical information. For more information,
refer to Table 4.
Table 4. IBM websites for help, services, and information
Website
Address
Directory of worldwide contacts
http://www.ibm.com/planetwide
Support for Storwize V3700 (2072)
www.ibm.com/storage/support/storwize/v3700
Support for IBM System Storage
and IBM TotalStorage products
www.ibm.com/storage/support/
Note: Available services, telephone numbers, and web links are subject to change
without notice.
Help and service
Before calling for support, be sure to have your IBM Customer Number available.
If you are in the US or Canada, you can call 1 (800) IBM SERV for help and
service. From other parts of the world, see http://www.ibm.com/planetwide for
the number that you can call.
When calling from the US or Canada, choose the storage option. The agent decides
where to route your call, to either storage software or storage hardware, depending
on the nature of your problem.
If you call from somewhere other than the US or Canada, you must choose the
hardware option when calling for assistance. When calling IBM for service
regarding the product, follow these guidelines for the hardware option:
xx
Storwize V3700: Quick Installation Guide
Hardware option
Provide the serial number and appropriate 4-digit machine type. For the
Storwize V3700, the machine type is 2072.
In the US and Canada, hardware service and support can be extended to 24x7 on
the same day. The base warranty is 9x5 on the next business day.
Getting help online
You can find information about products, solutions, partners, and support on the
IBM website.
To find up-to-date information about products, services, and partners, visit the IBM
website at www.ibm.com/storage/support/storwize/v3700.
Before you call
Make sure that you have taken steps to try to solve the problem yourself before
you call.
Some suggestions for resolving the problem before calling IBM Support include:
v Check all cables to make sure that they are connected.
v Check all power switches to make sure that the system and optional devices are
turned on.
v Use the troubleshooting information in your system documentation. The
troubleshooting section of the information center contains procedures to help
you diagnose problems.
v Go to the IBM Support website at www.ibm.com/storage/support/storwize/
v3700 to check for technical information, hints, tips, and new device drivers or
to submit a request for information.
Using the documentation
Information about your IBM storage system is available in the documentation that
comes with the product.
That documentation includes printed documents, online documents, readme files,
and help files in addition to the information center. See the troubleshooting
information for diagnostic instructions. The troubleshooting procedure might
require you to download updated device drivers or machine code. IBM maintains
pages on the web where you can get the latest technical information and download
device drivers and updates. To access these pages, go to www.ibm.com/storage/
support/storwize/v3700 and follow the instructions. Also, some documents are
available through the IBM Publications Center.
Sign up for the Support Line Offering
If you have questions about how to use the machine and how to configure the
machine, sign up for the IBM Support Line offering to get a professional answer.
The maintenance supplied with the system provides support when there is a
problem with a hardware component or a fault in the system machine code. At
times, you might need expert advice about using a function provided by the
system or about how to configure the system. Purchasing the IBM Support Line
About this guide
xxi
offering gives you access to this professional advice. Taking this advice while
deploying your system can save issues further down the line.
Contact your local IBM Sales or IBM Support for this offering availability and to
purchase it, if available in your country.
What's new
New and updated information was included in this version of the book as a result
of usability testing and other feedback. Read all of the steps no matter how
familiar you are with the installation.
xxii
Storwize V3700: Quick Installation Guide
Chapter 1. Before you begin the installation
Before you can begin installing your system, you must unpack and verify your
order and make other preparations.
1
1
1
The Quick Installation Guide contains a set of instructions to help you unpack and
install your system. The guide is divided into three chapters.
1. The steps in Chapter 1, “Before you begin the installation” (the chapter you are
now reading) involve verifying your order, becoming familiar with the
hardware component terminology, and ensuring that you have met the
environmental requirements.
2. The steps in Chapter 2, “Installing the hardware,” on page 11 involve installing
the hardware and attaching the data cables and power cords.
3. Chapter 3, “Configuring the system,” on page 45 helps you create your
configuration file and access the management GUI. The management GUI
guides you through the initial configuration process.
Important information:
v This guide presumes that you have read the planning information regarding
your physical environment that is available from the Storwize V3700 Information
Center.
v Ensure that any cables that you are supplying are available for installation.
1
Installation scenarios
1
1
1
1
1
1
Depending on your order, this documentation steps you through setting up your
system for the following scenarios:
1
1
1
1
1
v Setting up a new system that consists of a control enclosure only. In this case,
you are not installing any expansion enclosures.
v Setting up a new system that consists of a control enclosure and one or more
expansion enclosures.
v Adding an expansion enclosure to an existing system. In this case, you initially
installed a control enclosure (and, optionally, one or more expansion enclosures).
You want to add an expansion enclosure to your existing system. You do not
need to power off the system. You can add an expansion enclosure while the
system is operational.
1
Table 5. Steps for different installation scenarios
1
1
1
New system (control
enclosure only)
New system (control
enclosure and one or more
expansion enclosures)
Adding expansion
enclosures to an existing
system
1
1
“Reviewing your packing
slip” on page 5
“Reviewing your packing
slip” on page 5
“Reviewing your packing
slip” on page 5
1
1
“Identifying the hardware
components” on page 6
“Identifying the hardware
components” on page 6
“Verifying environmental
requirements” on page 10
1
1
1
“Verifying environmental
requirements” on page 10
“Verifying environmental
requirements” on page 10
“Reviewing enclosure
location guidelines” on page
10
© Copyright IBM Corp. 2012, 2013
1
1
Table 5. Steps for different installation scenarios (continued)
1
1
1
New system (control
enclosure only)
New system (control
enclosure and one or more
expansion enclosures)
Adding expansion
enclosures to an existing
system
1
1
1
“Reviewing enclosure
location guidelines” on page
10
“Reviewing enclosure
location guidelines” on page
10
“Installing the support rails”
on page 111
1
1
“Installing the support rails”
on page 11
“Installing the support rails”
on page 11
“Installing the enclosures” on
page 161
1
1
1
“Installing the enclosures” on “Installing the enclosures” on “Connecting SAS cables to
page 16
page 16
expansion enclosures” on
page 331
1
1
1
“Connecting Ethernet cables
for system management” on
page 36
1
1
“Connecting Fibre Channel
“Connecting Ethernet cables
cables to an 8 Gbps Fibre
for system management” on
Channel 4-port host interface page 36
card” on page 39
“Connecting SAS cables to
expansion enclosures” on
page 33
“Powering on the system” on
page 421
“Adding an expansion
enclosure to an existing
system” on page 52
“Powering on the system” on “Connecting Ethernet cables
page 42
for system management” on
page 36
Chapter 3, “Configuring the
system,” on page 45
“Powering on the system” on
page 42
Chapter 3, “Configuring the
system,” on page 45
1
Complete these steps for each expansion enclosure that you add.
Be familiar with the following information
1
v See “Caution notices for the Storwize V3700” on page x and “Danger notices for
Storwize V3700” on page xii for a summary of the situations that can be
potentially hazardous to you. Before installing, read and understand the
following caution and danger statements.
2
Storwize V3700: Quick Installation Guide
v Use safe practices when lifting. The fully populated enclosure weighs about 26
kg (57 lbs). At least two people are required to lift and install the enclosure into
the rack or to remove an enclosure from the rack.
18-32 kg (39.7-70.5 lbs)
32-55 kg (70.5-121.2 lbs)
55 kg ( 121.2 lbs)
svc00146
CAUTION:
Use safe practices when lifting.
(27)
Also keep in mind that a rack full of equipment is extremely heavy.
DANGER: Heavy equipment–personal injury or equipment damage might
result if mishandled. (D006)
v The following general precautions should be observed even though the power
on steps differ slightly from the directions that you will follow for this product:
Chapter 1. Before you begin the installation
3
DANGER
When working on or around the system, observe the following precautions:
Electrical voltage and current from power, telephone, and communication
cables are hazardous. To avoid a shock hazard:
– If IBM supplied a power cord(s), connect power to this unit only with
the IBM provided power cord. Do not use the IBM provided power cord
for any other product.
– Do not open or service any power supply assembly.
– Do not connect or disconnect any cables or perform installation,
maintenance, or reconfiguration of this product during an electrical
storm.
– The product might be equipped with multiple power cords. To remove
all hazardous voltages, disconnect all power cords.
– Connect all power cords to a properly wired and grounded electrical
outlet. Ensure that the outlet supplies proper voltage and phase rotation
according to the system rating plate.
– Connect any equipment that will be attached to this product to properly
wired outlets.
– When possible, use one hand only to connect or disconnect signal cables.
– Never turn on any equipment when there is evidence of fire, water, or
structural damage.
– Disconnect the attached power cords, telecommunications systems,
networks, and modems before you open the device covers, unless
instructed otherwise in the installation and configuration procedures.
– Connect and disconnect cables as described in the following procedures
when installing, moving, or opening covers on this product or attached
devices.
To disconnect:
1. Turn off everything (unless instructed otherwise).
2. Remove the power cords from the outlets.
3. Remove the signal cables from the connectors.
4.
To
1.
2.
3.
Remove all cables from the devices.
connect:
Turn off everything (unless instructed otherwise).
Attach all cables to the devices.
Attach the signal cables to the connectors.
4. Attach the power cords to the outlets.
5. Turn on the devices.
– Sharp edges, corners and joints may be present in and around the
system. Use care when handling equipment to avoid cuts, scrapes and
pinching. (D005)
Tools needed
A flat-blade screwdriver is the only tool needed for the system installation.
4
Storwize V3700: Quick Installation Guide
Reviewing your packing slip
After you open your shipment, you must verify the contents against the packing
slip.
In each box, locate the packing slip. Verify that the items listed in the packing slip
match what is in the box, and that any optional items that you ordered are
included in the list. Your shipment might contain additional items depending on
the order.
Note: If you purchased your equipment through a reseller, some of the options
might be preinstalled. Contact your supplier for details.
__ v Control enclosure or expansion enclosure:
– LFF enclosures have 12 Large Form Factor slots for 3.5-inch drives.
– SFF enclosures have 24 Small Form Factor slots for 2.5-inch drives.
Table 6. Storwize V3700 model numbers
Machine
type/model
Feature
code
Part
number
Description
2072-12C
ACAN
2072L2C
IBM Storwize V3700 LFF Dual Control Enclosure
2072-12E
ACAS
2072LEU
IBM Storwize V3700 LFF Expansion Enclosure
2072-24C
ACBN
2072S2C
IBM Storwize V3700 SFF Dual Control Enclosure
2072-24E
ACBS
2072SEU
IBM Storwize V3700 SFF Expansion Enclosure
__ v Rack-mounting hardware kit, including:
__ – Two rails (right and left assembly)
__ – Two rail springs
__ – Two sets of rail mounting screws
__ – Two sets of alternative rail mounting pins (large and small) for non-IBM
racks
__ v Two power cords for connection to rack mounted power distribution units
__ v Drive bay blanking plates (installed in the enclosure)
__ v Publications package (includes a USB flash drive that is used to initialize the
system)
Options applicable to control enclosures:
__ v Cache Memory Upgrade
__ v 4-port 8 Gbps Fibre Channel host interface card with 2 small form-factor
pluggable (SFP) transceivers installed
__ v 2 extra Fibre Channel SFP transceivers
1
__ v
__ v
__ v
__ v
__ v
Fibre Channel cables
SAS cables
4-port 1 Gbps iSCSI host interface card
2-port 10 Gbps iSCSI / FCoE host interface card
Drives
__ v Power cords for connection to wall sockets
Options applicable to expansion enclosures:
__ v Expansion enclosure attachment cables
Chapter 1. Before you begin the installation
5
__ v Drives
__ v Power cords for connection to wall sockets
Identifying the hardware components
The following graphics and descriptions identify the various hardware components
and port locations for the control enclosure and expansion enclosure.
Control enclosure components
Figure 1 shows the rear view of a control enclosure and identifies the location of
the power supply units and node canisters.
1
1
2
2
6
1
2
1
2
3
6
4
1
2
1
2
3
4
IN
IN
OK
OK
2
v3500112
1
Figure 1. Rear view of a Storwize V3700 control enclosure
v 1 Node canisters
v 2 Power supply units
Note: Figure 1 shows the node canisters in their initial configuration, with no host
interface card options installed.
6
Storwize V3700: Quick Installation Guide
Figure 2 shows the rear view of a Storwize V3700 control enclosure and identifies
the location of the ports.
3
1
1
2
2
6
2
1
1
2
3
6
4
1
2
1
2
3
4
IN
IN
OK
OK
1
v3500087
2
Figure 2. Data ports in the rear of the control enclosure
v 1 USB ports. Each canister has two USB ports. One port is used during
installation.
v 2 Ethernet ports. Each canister has two 1 Gbps Ethernet ports.
Port 1 Must be connected for system management. Can optionally be used for
iSCSI host connectivity.
3
3
3
Port 2 Optional. Can be used for iSCSI host connectivity or to provide an
alternative (redundant) management address.
v 3 Serial-attached SCSI (SAS) ports. Each canister has four SAS ports. Ports 1 to
3 are optionally used for connecting to host systems. Port 4 is optionally used
for connecting to expansion enclosures.
Chapter 1. Before you begin the installation
7
Expansion enclosure components
Figure 3 shows the rear view of an expansion enclosure and identifies the location
of power supply units and expansion canisters.
1
1
2
IN
IN
OK
OK
2
v3500058
2
1
Figure 3. Rear view of a Storwize V3700 expansion enclosure
v 1 Expansion canisters
v 2 Power supply units
Figure 4 shows the rear view of an expansion canister and identifies the SAS port
locations.
1
1
v3500080
2
2
Figure 4. SAS ports and LEDs in rear of expansion canister
v 1 LEDs
v 2 SAS ports
Each canister has two SAS ports that are numbered 1 on the left and 2 on the right.
Port 1 is always used. Port 2 is used only if this is not the last enclosure in the
chain.
Miscellaneous hardware
v3500070
The USB flash drive (Figure 5) is packaged with the publications and contains the
initialization tool for completing the initial system configuration.
Figure 5. USB flash drive
8
Storwize V3700: Quick Installation Guide
Chapter 1. Before you begin the installation
9
Verifying environmental requirements
The environmental and electrical requirements for the physical site must be met to
ensure that your system works reliably.
1
1
This procedure includes verifying that adequate space in a suitable rack is
available and that requirements for power and environmental conditions are met.
This documentation assumes that you have completed the physical planning for
the environment of your system.
If you have not done the environmental planning for your system, see the Storwize
V3700 physical installation planning topic in the Storwize V3700 Information Center.
Reviewing enclosure location guidelines
Before installing the enclosures, you must be familiar with these enclosure location
guidelines.
1
1
Installing a control enclosure only
If you are installing a control enclosure only, follow these guidelines.
Position the enclosure in the rack so that you can easily view it and access it for
servicing. Ensure that you locate the enclosure low enough for the rack to remain
stable and provide a way for two or more people to install and remove the
enclosure.
Installing a control enclosure and one or more expansion
enclosures
If you are installing a control enclosure plus one or more expansion enclosures,
follow these guidelines.
v Each Storwize V3700 enclosure to be installed requires 2U of rack space.
v Each assembled enclosure weighs more than 18kg. There must be sufficient
space at the front of the rack for two persons to carry the enclosure safely.
v Install all enclosures that constitute one system in contiguous positions in a rack.
Place the control enclosure at the top.
v Each control enclosure supports connection to up to four expansion enclosures.
If this system installation has fewer than four expansion enclosures, reserve
space directly below the system to allow future expansion.
v If a rack is to be only partially filled, install the enclosures low enough for the
rack to remain stable and enable easy access to the enclosures for servicing.
Adding an expansion enclosure to an existing system
If you are adding an expansion enclosure to an existing system, follow these
guidelines.
v You do not need to power off the system. You can add an expansion enclosure
while the system is operational.
v Add the first expansion enclosure directly below the control enclosure.
v Add the second expansion enclosure directly below the first, and so on.
10
Storwize V3700: Quick Installation Guide
Chapter 2. Installing the hardware
After verifying that you have all of the hardware components that you require,
you can install them.
You have completed the initial steps of verifying the shipping contents and
becoming familiar with the hardware components. You have verified that the
power and environmental requirements are met and have planned the location of
the enclosures. You are now ready to begin installing the hardware components
and connecting the data cables and power cords.
Installing the support rails
Before installing an enclosure, you must first install support rails.
Procedure
v3500168
To install the support rails, complete the following steps.
1. Locate the rack mounting rails and screws (Figure 6). The rail assembly
consists of two rails that must be installed in the rack cabinet.
Figure 6. Rack mounting rails and screws
1
2. Remove the springs that are taped to one of the rails.
© Copyright IBM Corp. 2012, 2013
11
v3500067
3. Attach a spring to the outside of each rail.
a. Attach the circle end of the spring around the stud on the rail (see
Figure 7).
b. Pulling on the spring, attach the hook end of the spring to the tab on the
rail.
Figure 7. Installing the rail spring
12
Storwize V3700: Quick Installation Guide
4. Working at the front of the rack cabinet, identify the two standard rack units
(2U) of space in the rack into which you want to install the support rails.
Figure 8 shows two rack units with the front mounting holes identified.
1
2
v3500162
3
Figure 8. Hole locations in the front of the rack
v 1 Upper rail mounting bracket pin
v 2 Lower rail mounting bracket pin
v 3 Rack mounting screw hole
1
1
1
e
e
e
Note: Each rail comes with two medium bracket pins in the front bracket and
two medium bracket pins in the rear bracket. The medium bracket pins are for
installation in a 19-inch IBM rack cabinet. If you are installing the storage
enclosure in a non-IBM rack cabinet, you may need to replace the set of
medium bracket pins on the front and rear of the rail with either the small or
large bracket pins that are included in the rail kit.
Chapter 2. Installing the hardware
13
5. At each end of the rail, grasp the tab 1 and pull firmly to open the hinge
bracket (see Figure 9).
v3500116
1
Figure 9. Opening the hinge brackets
6. Align the holes in the rail bracket with the holes on the front and rear rack
cabinet flanges. Ensure that the rails are aligned on the inside of the rack
cabinet.
14
Storwize V3700: Quick Installation Guide
v3500039
7. On the rear of the rail, press the two bracket pins into the holes in the rack
flanges and close the rear hinge bracket to secure the rail to the rack cabinet
flange (see Figure 10).
Figure 10. Closing hinge brackets and installing rear screw
8. On the front of the rail, press the two bracket pins into the holes in the rack
flanges and close the front hinge bracket to secure the rail to the rack cabinet
flange (see Figure 10).
9. Secure the rear of the rail to the rear rack flange with an M5 screw (see
Figure 10).
10. Repeat the steps to secure the opposite rail to the rack cabinet.
11. Repeat the procedure to install rails for each additional enclosure.
Chapter 2. Installing the hardware
15
Installing the enclosures
Following your enclosure location plan, install the control enclosure (and,
optionally, one or more expansion enclosures).
1
1
About this task
CAUTION:
v To lift and install the enclosure into the rack requires at least two people.
v Load the rack from the bottom up to ensure rack stability. Empty the rack
from the top down.
Procedure
To install an enclosure, complete the following steps.
1. Align the enclosure with the front of the rack cabinet.
2. Carefully slide the enclosure into the rack along the rails until the enclosure is
fully inserted (see Figure 11).
1
v3500047
Note: The rails are not designed to hold an enclosure that is partially inserted.
The enclosure must always be in a fully inserted position.
Figure 11. Inserting the enclosure
3. On either side of the drive assemblies, remove the enclosure end caps by
grasping the handle and pulling the bottom of the end cap free, then clearing
the tab on the top of the enclosure.
4. Secure the enclosure with a screw in the rack mounting screw hole.
16
Storwize V3700: Quick Installation Guide
5. Reinstall the left and right end caps as shown in Figure 11 on page 16. The left
end cap has indicator windows that align with the status LEDs (light-emitting
diodes) on the edge of the enclosure.
a. Ensure that the serial number of the end cap matches the serial number on
the rear of the enclosure.
b. Fit the slot on the top of the end cap over the tab on the chassis flange.
c. Rotate the end cap down until it snaps into place.
d. Ensure that the inside surface of the end cap is flush with the chassis.
Installing options in the control enclosure
If you have purchased host interface cards or cache memory upgrades for your
control enclosure and those options were not preinstalled for you, you must open
each node canister and install the options.
Note: You must install the same options in all node canisters.
1
1
1
1
First, open the canister as described in “Opening the node canister” on page 18.
Then refer to the procedure for the option you are installing.
v “Installing an 8 Gbps Fibre Channel 4-port host interface card” on page 20
v “Installing a 10 Gbps iSCSI-FCoE 2-port host interface card” on page 22
v “Installing a 1 Gbps iSCSI 4-port host interface card” on page 24
v “Installing a SAS 4-port host interface card” on page 26
v “Installing an 8 GB cache memory upgrade” on page 27
Finally, close the canister and install it in the control enclosure (see “Closing the
node canister” on page 30).
Note: Disk drives can also be installed in the control enclosure, but that procedure
does not involve opening any node canisters. See “Installing disk drives” on page
32 for details.
Chapter 2. Installing the hardware
17
Opening the node canister
Before you can install options in a node canister, you must gain access by opening
the canister cover.
Procedure
To open the canister, complete the following steps.
1. If the canister is already installed in the enclosure, remove it as shown in
Figure 12.
a. Unlatch the release levers and pull them open. The canister moves out of
the slot approximately 0.6cm (0.25 inch).
b. Slide the canister out of the enclosure.
IN
OK
IN
v3500099
OK
Figure 12. Removing a node canister
18
Storwize V3700: Quick Installation Guide
v3500178
2. Turn the canister over and open the cover as shown in Figure 13.
a. Press the recessed blue touch points on the cover.
b. Slide the cover away from the thumbscrew end of the canister.
Figure 13. Removing the canister cover
Chapter 2. Installing the hardware
19
Installing an 8 Gbps Fibre Channel 4-port host interface card
1
If you purchased an FC ACHK 8 Gbps Fibre Channel 4-port host interface card
that was not preinstalled for you, you must install it in the node canister.
1
1
Before you begin
The 8 Gbps Fibre Channel 4-port host interface card is installed in the node
canisters in the control enclosure. If your control enclosure has two node canisters,
you must install the same options in both canisters. Do not start installation until
you have two of the 8 Gbps Fibre Channel 4-port host interface card options.
1
1
About this task
Note: The host interface card has four ports, but only two small form-factor
pluggable (SFP) transceivers are installed.
Procedure
v3500166
To install the host interface card, complete the following steps.
1. Remove the SFP transceivers from the host interface card (Figure 14). To
remove an SFP transceiver, swing the release handle open and use it to pull
the transceiver out of the port.
Figure 14. Host interface card and SFP transceivers
20
Storwize V3700: Quick Installation Guide
2. Loosen the retaining thumbscrew 1 as shown in Figure 15.
4
3
2
v3500104
1
1
Figure 15. Installing 8 Gbps Fibre Channel 4-port host interface card
v 1 Retaining thumbscrew
v 2 Filler handle
3.
4.
5.
6.
7.
8.
v 3 Host interface card
v 4 Catch slot
From inside the canister, grasp the filler handle 2 and slide the filler plate
toward the thumbscrew to disengage the plate from the catch slot 4.
Remove the filler plate.
Insert the host interface card 3 into the canister as shown in Figure 15
Align the mounting bracket of the host interface card with the inside of the
host interface card aperture at the thumbscrew end of the canister, ensuring
that the tab at the end of the faceplate is aligned with the catch slot 4.
Align the connecting edge of the host interface card with the slot in the host
interface card connector inside the canister.
Apply pressure to the opposite edge of the host interface card to push the
card into the host interface card connector.
Chapter 2. Installing the hardware
21
9. Check that the host interface card is installed squarely in its slot and tighten
the retaining thumbscrew 1.
10. Reinstall the SFP transceivers. To install a transceiver, push it fully into the
port and close the release handle.
11. If you purchased the additional 2-transceiver option, install the extra SFP
transceivers in the remaining ports.
1
1
Installing a 10 Gbps iSCSI-FCoE 2-port host interface card
1
1
1
If you purchased an FC ACHM 10 Gbps iSCSI-FCoE 2-port host interface card that
was not pre-installed for you, you must install it in the node canister.
1
Before you begin
1
1
1
1
The 10 Gbps iSCSI-FCoE 2-port host interface card is installed in the node canisters
in the control enclosure. If your control enclosure has two node canisters, you must
install the same options in both canisters. Do not start installation until you have
two of the 10 Gbps iSCSI-FCoE 2-port host interface card options.
Procedure
To install the host interface card, complete the following steps.
1. Remove each SFP transceiver from the host interface card. To remove an SFP
transceiver, swing the release handle open and use it to pull the transceiver out
of the port.
2. Remove the filler plate from the host interface card slot.
a. Loosen the retaining thumbscrew 1 as shown in Figure 16 on page 23.
22
Storwize V3700: Quick Installation Guide
4
3
2
v3500104
1
1
Figure 16. Installing 10 Gbps iSCSI-FCoE 2 port host interface card
v
v
v
v
1
2
3
4
Retaining thumbscrew
Filler handle
Host interface card
Catch slot
b. From inside the canister, grasp the filler handle 2 and slide the filler plate
toward the center of the canister to disengage the plate from the catch slot.
c. Remove the filler plate.
1
1
1
3. Insert the 10 Gbps iSCSI-FCoE 2-port host interface card 3 into the canister as
shown in Figure 16.
4. Align the mounting bracket of the host interface card with the inside of the
host interface card aperture (adjacent to the thumbscrew), ensuring that the tab
at the end of the faceplate is aligned with the catch slot.
5. Align the connecting edge of the host interface card with the slot in the host
interface card connector inside the canister.
6. Apply pressure to the opposite edge of the host interface card to push the card
into the host interface card connector.
Chapter 2. Installing the hardware
23
7. Check that the host interface card is installed squarely in its slot and tighten the
retaining thumbscrew 1.
8. Reinstall the SFP transceivers that were removed in step 1 on page 22. To install
a transceiver, push it fully into the port and close the release handle.
Note: Return the SFP transceivers to the same ports they were removed from.
Installing a 1 Gbps iSCSI 4-port host interface card
1
1
1
If you purchased an FC ACHL 1 Gbps iSCSI 4-port host interface card that was not
pre-installed for you, you must install it in the node canister.
1
Before you begin
1
1
1
1
The 1 Gbps iSCSI 4-port host interface card is installed in the node canisters in the
control enclosure. If your control enclosure has two node canisters, you must
install the same options in both canisters. Do not start installation until you have
two of the 1 Gbps iSCSI 4-port host interface card options.
Procedure
To install the host interface card, complete the following steps.
1. Loosen the retaining thumbscrew 1 as shown in Figure 17 on page 25.
24
Storwize V3700: Quick Installation Guide
4
3
2
v3500104
1
1
Figure 17. Installing 1 Gbps iSCSI 4-port host interface card
v
v
v
v
1
2
3
4
Retaining thumbscrew
Filler handle
Host interface card
Catch slot
2. From inside the canister, grasp the filler handle 2 and slide the filler plate
toward the center of the canister to disengage the plate from the catch slot.
3. Remove the filler plate.
4. Insert the host interface card 3 into the canister as shown in Figure 17.
5. Align the mounting bracket of the host interface card with the inside of the
host interface card aperture at the rear of the canister, ensuring that the tab at
the end of the faceplate is aligned with the catch slot.
6. Align the connecting edge of the host interface card with the slot in the host
interface card connector inside the canister.
7. Apply pressure to the opposite edge of the host interface card to push the card
into the host interface card connector.
8. Check that the host interface card is installed squarely in its slot and tighten the
retaining thumbscrew 1.
Chapter 2. Installing the hardware
25
Installing a SAS 4-port host interface card
1
1
1
If you purchased an FC ACHJ SAS 4-port host interface card that was not
pre-installed for you, you must install it in the node canister.
1
Before you begin
1
1
1
1
The SAS 4-port host interface card is installed in the node canisters in the control
enclosure. If your control enclosure has two node canisters, you must install the
same options in both canisters. Do not start installation until you have two of the
SAS 4-port host interface card options.
1
Procedure
1
1
1
1
To install the host interface card, complete the following steps.
1. Loosen the retaining thumbscrew 1 as shown in Figure 18.
4
3
2
v3500104
1
1
1
1
1
1
Figure 18. Installing SAS 4-port host interface card
v 1 Retaining thumbscrew
v 2 Filler handle
26
Storwize V3700: Quick Installation Guide
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
2.
3.
4.
5.
v 3 Host interface card
v 4 Catch slot
From inside the canister, grasp the filler handle 2 and slide the filler plate
toward the center of the canister to disengage the plate from the catch slot.
Remove the filler plate.
Insert the host interface card 3 into the canister as shown in Figure 18 on
page 26.
Align the mounting bracket of the host interface card with the inside of the
host interface card aperture at the rear of the canister, ensuring that the tab at
the end of the faceplate is aligned with the catch slot.
6. Align the connecting edge of the host interface card with the slot in the host
interface card connector inside the canister.
7. Apply pressure to the opposite edge of the host interface card to push the card
into the host interface card connector.
8. Check that the host interface card is installed squarely in its slot and tighten the
retaining thumbscrew 1.
Installing an 8 GB cache memory upgrade
If you purchased an FC ACHB 8 GB Cache Upgrade option that was not
pre-installed for you, you must install it.
Before you begin
The 8 GB Cache Upgrade option is installed in the node canisters in the control
enclosure. If your control enclosure has two node canisters, you must install the
same options in both canisters. Do not start installation until you have two of the
Cache Upgrade options.
About this task
The Cache Upgrade option consists of a 4 GB memory module. When added to a
node canister, it increases the total memory in the canister to 8 GB.
The memory module is inserted into memory slot 2, located between the existing
memory module and the battery (Figure 19 on page 28).
Chapter 2. Installing the hardware
27
v3500101
Figure 19. Where to install the cache memory upgrade
Procedure
To install the memory module option, complete the following steps.
1. Open the retaining clip on each end of the memory module connector as
shown in Figure 20 on page 29.
Attention: To avoid breaking the retaining clips or damaging the memory
module connectors, open and close the clips gently.
28
Storwize V3700: Quick Installation Guide
v3500052
Figure 20. Installing memory module option
2. Touch the static-protective package that contains the memory module to any
unpainted metal surface on the outside of the canister.
3. Remove the memory module from the package.
4. Turn the memory module so that the keys align correctly with the connector.
5. Insert the memory module into the connector by aligning the edges of the
module with the slots at the ends of the connector (see Figure 20).
6. Firmly press the memory module straight down into the connector by applying
pressure on both ends of the module simultaneously. The retaining clips snap
into the locked position when the module is firmly seated in the connector.
Note: If you can see a gap between the module and the retaining clips, the
module has not been correctly inserted. Open the retaining clips, remove the
module, and then reinsert it.
Chapter 2. Installing the hardware
29
Closing the node canister
After installing options in a node canister, you must close the canister cover and
install the canister in the control enclosure.
Procedure
To close the canister, complete the following steps.
1. Reinstall the cover as shown in Figure 21.
a. Align the four hook slots on the cover with the pins on the canister.
b. Slide the cover toward the latch and release levers until it locks into place.
v3500115
1
Figure 21. Reinstalling the canister cover
30
Storwize V3700: Quick Installation Guide
2. Turn the canister over and install it in the control enclosure as shown in
Figure 22.
a. With the latch and release levers fully extended, slide the canister into the
enclosure until the levers begin to move inwards.
b. Simultaneously close both latch and release levers.
IN
OK
IN
v3500100
OK
Figure 22. Installing a node canister
Chapter 2. Installing the hardware
31
Installing disk drives
If you purchased disk drives that were not preinstalled for you, you must install
them.
About this task
Drives can be installed in the control enclosure or any of the expansion enclosures.
The installation procedure is the same for either enclosure type.
Install all the drives you require before configuring the system. This allows the
best provisioning of drives into arrays.
Procedure
To install a drive, complete the following steps.
1. Remove the filler panel from the slot into which you want to install the drive
(as shown in Figure 23).
a. Grip the front of the filler panel 1 and pull firmly to remove it from the
the drive slot.
1
v3500164
b. Save the filler panel for future use.
Figure 23. Removing a filler panel
v 1 Filler panel
2. Touch the static-protective package that contains the drive to any unpainted
surface on the outside of the enclosure.
3. Remove the drive from the package.
32
Storwize V3700: Quick Installation Guide
v3500043
4. Install the drive in the empty slot as shown in Figure 24.
a. Ensure that the drive-tray handle is in the open (unlocked) position.
b. Align the drive assembly with the guide rails in the slot.
c. Gently push the drive assembly into the slot until the drive stops.
d. Rotate the drive handle to the closed (locked) position.
Figure 24. Installing a drive
Connecting SAS cables to expansion enclosures
This task applies if you are installing one or more expansion enclosures to a
control enclosure.
Before you begin
If you purchased disk drives that were not pre-installed for you, you must install
all of the drives before connecting the SAS cables to the expansion enclosures.
About this task
This task applies if you are installing one or more expansion enclosures. You can
attach up four expansion enclosures to the control enclosure.
Note: When inserting SAS cables, make sure the connector (Figure 25 on page 34)
is oriented correctly.
v The blue pull tab must be below the connector.
Chapter 2. Installing the hardware
33
v3500179
v Insert the connector gently until it clicks into place. If you feel resistance, the
connector is probably oriented the wrong way. Do not force it.
v When inserted correctly, the connector can only be removed by pulling the tab.
Figure 25. SAS cable connectors
Be aware of the following guidelines when you begin to attach the cables to the
SAS ports.
v No more than two expansion enclosures can be chained to port 4.
v No cable can be connected between a port on an left canister and a port on a
right canister.
v Attach cables serially between enclosures; do not skip an enclosure.
e
e
v The last enclosure in a chain must not have cables in port 2 of canister 1 and
port 2 of canister 2.
v Ensure that cables are installed in an orderly way to reduce the risk of cable
damage when replaceable units are removed or inserted.
v Arrange your cables to provide access to:
– USB ports. USB port access is required when you use a USB flash drive to
configure the system.
– The enclosures themselves. Access is required to the hardware for servicing
and for safely removing and replacing components using two or more people.
Procedure
To install the cables, complete the following steps.
1. Using the supplied SAS cables, connect the control enclosure to the first
expansion enclosure as shown in Figure 26 on page 35.
a. Connect SAS port 4 of the left node canister in the control enclosure to SAS
port 1 of the left expansion canisters in the first expansion enclosure.
b. Connect SAS port 4 of the right node canister in the control enclosure to
SAS port 1 of the right expansion canisters in the first expansion enclosure.
34
Storwize V3700: Quick Installation Guide
6
1
1
2
1
2
2
3
1
1
4
2
6
1
3
6
4
1
2
1
2
3
4
IN
IN
OK
OK
2
1
2
IN
IN
OK
OK
2
1
2
IN
IN
OK
OK
1
2
v3500050
1
2
Figure 26. Connecting the SAS cables
1
1
1
1
1
1
2. If additional expansion enclosures are installed, connect each one to the
previous expansion enclosure as shown in Figure 26.
a. Use one cable to connect SAS port 2 of the left expansion canister in the
previous expansion enclosure to SAS port 1 of the left expansion canister in
the newly installed expansion enclosure.
b. Use the second cable to connect SAS port 2 of the right expansion canister
in the previous expansion enclosure to SAS port 1 of the right expansion
canister in the newly installed expansion enclosure.
Note: A control enclosure can support up to four expansion enclosures.
Chapter 2. Installing the hardware
35
Connecting Ethernet cables for system management
To provide system management connectivity, you must connect Ethernet cables to
Ethernet port 1 of each node canister in the control enclosure. This connection can
optionally also be used for iSCSI host connection. Ethernet port 2 can optionally be
connected to provide a second system management address, a second iSCSI host
connection, or both.
1
1
1
1
1
About this task
Procedure
To install the cables, complete the following steps.
1. Connect Ethernet port 1 on each node canister to the same Ethernet switch, as
shown in Figure 27.
1
2
2
6
1
2
1
2
3
6
4
1
2
1
2
3
4
IN
IN
OK
OK
v3500001
1
Figure 27. Connecting the Ethernet cables
2. Optionally, connect Ethernet port 2 on each node canister to the same Ethernet
switch. (Figure 27 shows these optional cables in a lighter color.)
1
1
1
Connecting Ethernet cables to 1 Gbps iSCSI 4-port host interface
cards
1
1
If you installed 1 Gbps iSCSI 4-port host interface cards, you must connect
Ethernet cables to them.
About this task
The Ethernet port numbering on the host interface card starts at 3, because
Ethernet ports one and two are built into the canister.
Note: The Ethernet cables are connected in pairs. Both canisters must have the
same number of cables connected.
1
1
Procedure
To install the cables, complete the following steps.
1. Identify the correct pair of Ethernet cables for the Ethernet ports labeled 3 in
the left canister and the right canister.
2. Connect the appropriate cable to each port.
1
1
1
36
Storwize V3700: Quick Installation Guide
1
1
3. For each additional pair of Ethernet ports in the right and left canisters,
identify the correct pair of cables and connect them.
1
Results
1
1
1
1
Figure 28 shows an example configuration with a pair of Ethernet cables connected
to port 3 in each canister, and another pair connected to port 4 in each canister.
1
2
2
6
6
3
1
1
1
1
2
1
2
3
3
6
4
1
2
1
2
3
6
4
IN
IN
OK
OK
v3500103
1
Figure 28. Example configuration with two pairs of Ethernet cables connected to 1 Gbps
iSCSI 4-port host interface cards
1
Connecting fibre cables to a 10 Gbps iSCSI-FCoE 2-port host interface
card
1
1
If you installed a 10 Gbps iSCSI-FCoE 2-port host interface card, you must connect
fibre cables to it.
About this task
The Ethernet port numbering on the host interface card starts at 3, because
Ethernet ports one and two are built into the canister.
1
1
Note: The fibre cables are connected in pairs. Both canisters must have the same
number of cables connected.
Procedure
1
1
1
1
1
To install the cables, complete the following steps.
1. Identify the correct pair of fibre cables for the Ethernet ports labeled 3 in the
left canister and the right canister.
2. Connect the appropriate cable to each port.
3. For each additional pair of Ethernet ports in the right and left canisters,
identify the correct pair of cables and connect them.
1
Results
1
1
1
1
Figure 29 on page 38 shows an example configuration with a pair of Ethernet
cables connected to port 3 in each canister, and another pair connected to port 4 in
each canister.
Chapter 2. Installing the hardware
37
1
1
2
6
TxRx
1
2
6
2
TxRx
LNK
1
1
1
1
2
1
2
3
1
2
LNK
4
1
2
1
2
3
4
IN
IN
OK
OK
Figure 29. Example configuration with two pairs of Ethernet cables connected to 10 Gbps
iSCSI-FCoE 2-port host interface cards
38
Storwize V3700: Quick Installation Guide
v3500102
1
1
1
1
Connecting Fibre Channel cables to an 8 Gbps Fibre Channel 4-port
host interface card
If you installed an 8 Gbps Fibre Channel 4-port host interface card, you must
connect Fibre Channel cables to it.
Procedure
To install the cables, complete the following steps.
1. Connect the required number of Fibre Channel cables. Refer to the “Planning”
section of the information center for instructions on determining the number of
cables required.
Note: Both canisters must have the same number of cables connected.
Figure 30 shows an example configuration with two Fibre Channel cables
connected to each canister.
1
2
2
6
1
2
1
2
3
6
4
1
2
1
2
3
4
IN
IN
OK
OK
v3500098
1
Figure 30. Example configuration with two Fibre Channel cables per canister
2. If you want to connect additional Fibre Channel cables, make sure to connect
the same number of cables to each canister. Figure 31 shows an example
configuration with four Fibre Channel cables connected to each canister.
1
2
2
6
1
2
1
2
3
6
4
1
2
1
2
3
4
IN
IN
OK
OK
v3500062
1
Figure 31. Example configuration with four Fibre Channel cables per canister
1
Connecting SAS cables to a host
1
When installing a control enclosure, you can connect it to a host with SAS cables.
1
About this task
1
1
1
Two types of SAS cables are used for host attachment, depending on the
requirements of the host.
v Mini SAS HD to Mini SAS HD (Figure 32 on page 40)
v Mini SAS HD to Mini SAS (Figure 33 on page 40)
1
1
Chapter 2. Installing the hardware
39
v3500179
1
1
1
1
1
1
ite00052
Figure 32. Mini SAS HD to Mini SAS HD cable
1
1
1
1
Figure 33. Mini SAS HD to Mini SAS cable
Note: When inserting SAS cables, make sure the connector is oriented correctly.
v When connecting to the SAS ports on the left side of the node canister, the blue
pull tab must be below the connector.
1
1
1
1
1
1
1
v When connecting to a SAS 4-port host interface card, the blue pull tab must be
above the connector.
v Insert the connector gently until it clicks into place. If you feel resistance, the
connector is probably oriented the wrong way. Do not force it.
v When inserted correctly, the connector can only be removed by pulling the tab.
1
Procedure
1
1
1
1
To install the cables, complete the following steps.
1
1
1
1
Note: When connecting to the SAS ports on the left side of the node canister,
each host must be connected to both canisters. Both canisters must have the
same number of cables connected.
2. Arrange the cables to provide access to the hardware.
1. Connect the required number of SAS cables. Refer to the “Planning” section of
the information center for instructions on determining the number of cables
required.
40
Storwize V3700: Quick Installation Guide
v USB ports. USB port access is required when you use a USB flash drive to
configure the system.
v The enclosures themselves. Access is required to the hardware for servicing
and for safely removing and replacing components using two or more
people.
1
1
1
1
1
1
Results
1
1
1
1
Figure 34 shows an example configuration with three SAS cables connected to each
canister.
1
2
2
6
1
2
3
6
4
1
2
1
2
3
4
IN
IN
OK
OK
Figure 34. Example configuration with three SAS cables per canister
Figure 35 shows an example configuration with two SAS cables connected to a SAS
4-port host interface card.
1
1
2
2
6
6
3
1
1
1
1
2
1
2
3
3
6
4
1
2
1
2
3
6
4
IN
IN
OK
OK
v3500103
1
1
1
1
1
1
1
2
1
v3500180
1
Figure 35. Example configuration with two SAS cables connected to a SAS 4-port host
interface card
Chapter 2. Installing the hardware
41
Powering on the system
After installing all hardware components, you must power on the system and
check its status.
About this task
Attention: Do not power on the system with any open bays or slots.
v Every unused drive bay must be occupied by a filler panel.
v Filler plates must be installed in all empty canister bays and host interface card
slots.
1
Open bays or slots disrupt the internal air flow, causing the drives to receive
insufficient cooling.
Procedure
To power on the system, complete the following steps.
1. Power on all expansion enclosures by plugging the power cords into properly
grounded electrical outlets. There is no power switch.
1
1
2
3
v3500064
Note: Each enclosure has two power supply units. To provide power failure
redundancy, connect the two power cords to separate power circuits.
2. Check the LEDs on each expansion canister (see Figure 36).
Figure 36. Expansion canister LEDs
v 1 Power
v 2 Status
v 3 Fault
The canister is ready with no critical errors when Power is illuminated, Status
is illuminated, and Fault is off. If a canister is not ready, refer to the Procedure:
Understanding the system status using the LEDs topic in the troubleshooting
section of the Storwize V3700 Information Center.
3. Wait for all expansion canisters to finish powering on.
4. Plug the power cord of each power supply in the control enclosure into a
properly grounded electrical outlet.
Note: Each enclosure has two power supply units. To provide power failure
redundancy, connect the two power cords to separate power circuits.
5. Check the LEDs on each node canister in the control enclosure (see Figure 37
on page 43).
42
Storwize V3700: Quick Installation Guide
2
3
v3500064
1
Figure 37. Node canister LEDs
v 1 Power
v 2 Status
v 3 Fault
The canister is ready with no critical errors when Power is illuminated, Status
is blinking, and Fault is off. If a canister is not ready, refer to the Procedure:
Understanding the system status using the LEDs topic in the troubleshooting
section of the Storwize V3700 Information Center.
Chapter 2. Installing the hardware
43
44
Storwize V3700: Quick Installation Guide
Chapter 3. Configuring the system
Configuring your system is necessary in two situations: when you power up a new
system for the first time, and when you add an expansion enclosure to an existing
system.
1
1
1
1
1
The following instructions use the supplied USB flash drive to initialize the system.
If you are not authorized to use a USB flash drive in your situation, refer to the
“Troubleshooting” section of the Information Center for details on how to make an
Ethernet connection to the enclosure and to initialize the system using the service
assistant GUI.
1
1
After initializing the system, you will use the Storwize management GUI to
complete the configuration procedures.
v The management GUI requires a supported web browser (see “Web browser
requirements to access the management GUI”).
v To configure a new system, you will log on to the management GUI with the
default user name and password (see “User name and password for system
initialization” on page 46).
1
1
1
1
1
The steps for initializing a new system vary, depending on the operating system of
the computer you use for the procedure.
v “Initializing the system with a Microsoft Windows computer” on page 47
v “Initializing the system with an Apple Macintosh computer” on page 49
v “Initializing the system with a Linux computer” on page 51
1
1
The steps for adding an expansion enclosure to an existing system are described in
“Adding an expansion enclosure to an existing system” on page 52.
Web browser requirements to access the management GUI
You must have a supported Web browser to access the management GUI.
The management GUI supports the following web browsers:
v Mozilla Firefox 18
v Mozilla Firefox Extended Support Release (ESR) 17
v Microsoft Internet Explorer (IE) 8 and 9
v Google Chrome 24
IBM supports higher versions of the browsers as long as the vendors do not
remove or disable functionality that the product relies upon. For browser levels
higher than the versions that are certified with the product, customer support
accepts usage-related and defect-related service requests. As with operating system
and virtualization environments, if IBM support cannot re-create the issue in our
lab, we might ask the client to re-create the problem on a certified browser version
to determine whether a product defect exists. Defects are not accepted for cosmetic
differences between browsers or browser versions that do not affect the functional
behavior of the product. If a problem is identified in the product, defects are
© Copyright IBM Corp. 2012, 2013
45
accepted. If a problem is identified with the browser, IBM might investigate
potential solutions or work-arounds that the client can implement until a
permanent solution becomes available.
User name and password for system initialization
During the initialization procedure, you will need to log in to the Storwize
management GUI.
The default user name and password for the management GUI are listed in Table 7.
Table 7. Default user name and password for the management GUI
User name
Password
superuser
passw0rd
Note: The 0 character in the password is a zero, not the letter O.
46
Storwize V3700: Quick Installation Guide
1
Initializing the system with a Microsoft Windows computer
1
1
To initialize a new system with a Microsoft Windows computer, use the
initialization tool that was shipped with your order.
1
1
1
Before you begin
1
1
1
1
1
v Begin this procedure after you have installed all the enclosures, drives and other
options you have purchased.
v You need a personal computer to complete the initialization procedure. The
personal computer must have:
– A USB port
– A supported browser (see “Web browser requirements to access the
management GUI” on page 45)
For best results, the personal computer and the Storwize system must be
connected to the same network.
1
1
1
About this task
1
3
3
1
1
This procedure is valid for Microsoft Windows 7 (64-bit) or XP (32-bit).
v Use this procedure only when initializing a new control enclosure (with,
optionally, one or more expansion enclosures).
v Do not use this procedure when adding an expansion enclosure to an existing
system.
1
Procedure
1
To initialize the system, complete the following steps.
1. Gather the information you will use to configure the system.
v You must have the IP network address you will use to manage the system.
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
– IP address
– Subnet mask
– Gateway
v Other information is optional, but useful for enabling additional capabilities.
– The IP address of a Network Time Protocol (NTP) server for automated
setting of date and time
2.
3.
4.
5.
6.
– The IP address of a simple mail transfer protocol (SMTP) server for
sending notificatication of alerts
Locate the USB flash drive that was shipped with your order in the
documentation package.
Insert the USB flash drive into a USB port on the personal computer.
To launch the tool, open the USB flash drive. and double-click InitTool.bat
The initialization tool wizard starts.
In the wizard, click Next and select Create a new system.
Follow the on-screen instructions given by the initialization tool. You will be
instructed to complete the following actions:
a. Enter the details of the system management address you wish to use.
b. Take the USB flash drive to the Storwize system and allow it to initialize.
c. Return the flash drive to the workstation to check that the initialization
completed.
Chapter 3. Configuring the system
47
1
1
1
1
1
1
7. If the system initialization completed successfully, click Finish. If you have a
network connection to the Storwize system, the system management GUI is
displayed. If the workstation does not have a network connection to the
Storwize system, go to the workstation you will use to manage the system and
start a supported browser. Direct the browser to the management address you
specified for the system.
1
8.
1
1
Note: The 0 character in the password is a zero, not the letter O.
9. Follow the on-screen instructions to begin setting up your system.
Log in with user name superuser and password passw0rd.
Note: The other options that are available in the initialization tool are used to
recover the service IP address or the superuser password.
1
1
1
48
Storwize V3700: Quick Installation Guide
1
Initializing the system with an Apple Macintosh computer
1
1
To initialize a new system with an Apple Macintosh computer, use the
initialization tool that was shipped with your order.
1
1
1
Before you begin
1
1
1
1
1
1
1
v Begin this procedure after you have installed all the enclosures, drives and other
options you have purchased.
v You need a personal computer to complete the initialization procedure. The
personal computer must have:
– A USB port
– A supported browser (see “Web browser requirements to access the
management GUI” on page 45)
For best results, the personal computer and the Storwize system must be
connected to the same network.
1
About this task
1
3
3
1
1
This procedure is valid for Apple MacOS X 10.7.
v Use this procedure only when initializing a new control enclosure (with,
optionally, one or more expansion enclosures).
v Do not use this procedure when adding an expansion enclosure to an existing
system.
1
Procedure
1
To initialize the system, complete the following steps.
1. Gather the information you will use to configure the system.
v You must have the IP network address you will use to manage the system.
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
– IP address
– Subnet mask
– Gateway
2.
3.
4.
5.
6.
7.
8.
v Other information is optional, but useful for enabling additional
capabilities.
– The IP address of a Network Time Protocol (NTP) server for automated
setting of date and time
– The IP address of a simple mail transfer protocol (SMTP) server for
sending notificatication of alerts
Locate the USB flash drive that was shipped with your order in the
documentation package.
Insert the USB flash drive into a USB port on the personal computer.
Open a terminal window.
Locate the root directory of the USB flash drive. The root directory is usually
located in the /Volumes/ directory.
Type: sh InitTool.sh The initialization tool wizard starts.
In the wizard, click Next and select Create a new system.
Follow the on-screen instructions given by the initialization tool. You will be
instructed to complete the following actions:
a. Enter the details of the system management address you wish to use.
b. Take the USB flash drive to the Storwize system and allow it to initialize.
Chapter 3. Configuring the system
49
1
1
1
1
1
1
1
1
1
c. Return the flash drive to the workstation to check that the initialization
completed.
9. If the system initialization completed successfully, click Finish. If you have a
network connection to the Storwize system, the system management GUI is
displayed.If the workstation does not have a network connection to the
Storwize system, go to the workstation you will use to manage the system
and start a supported browser. Direct the browser to the management address
you specified for the system.
10. Log in with user name superuser and password passw0rd.
1
1
Note: The 0 character in the password is a zero, not the letter O.
11. Follow the on-screen instructions to begin setting up your system.
Note: The other options in the initialization tool are used to reset the service
IP address or the superuser password.
1
1
1
50
Storwize V3700: Quick Installation Guide
1
Initializing the system with a Linux computer
1
1
To initialize a new system with a Linux computer, use the initialization tool that
was shipped with your order.
1
1
1
Before you begin
1
1
1
1
1
1
1
v Begin this procedure after you have installed all the enclosures, drives and other
options you have purchased.
v You need a personal computer to complete the initialization procedure. The
personal computer must have:
– A USB port
– A supported browser (see “Web browser requirements to access the
management GUI” on page 45)
For best results, the personal computer and the Storwize system must be
connected to the same network.
1
About this task
1
3
3
1
1
This procedure is valid for Red Hat Enterprise Server 5 or Ubuntu desktop 11.04.
v Use this procedure only when initializing a new control enclosure (with,
optionally, one or more expansion enclosures).
v Do not use this procedure when adding an expansion enclosure to an existing
system.
1
Procedure
1
To initialize the system, complete the following steps.
1. Gather the information you will use to configure the system.
v You must have the IP network address you will use to manage the system.
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
– IP address
– Subnet mask
– Gateway
2.
3.
4.
5.
v Other information is optional, but useful for enabling additional
capabilities.
– The IP address of a Network Time Protocol (NTP) server for automated
setting of date and time
– The IP address of a simple mail transfer protocol (SMTP) server for
sending notificatication of alerts
Locate the USB flash drive that was shipped with your order in the
documentation package.
Insert the USB flash drive into a USB port on the personal computer.
Open a terminal window.
Locate the root directory of the USB flash drive. It is usually located in the
/media/ directory. If an automatic mount system is used, the root directory
can be located by typing the mount command.
6. Type: sh InitTool.sh The initialization tool wizard starts.
7. In the wizard, click Next and select Create a new system.
8. Follow the on-screen instructions given by the initialization tool. You will be
instructed to complete the following actions:
a. Enter the details of the system management address you wish to use.
Chapter 3. Configuring the system
51
b. Take the USB flash drive to the Storwize system and allow it to initialize.
c. Return the flash drive to the workstation to check that the initialization
completed.
9. If the system initialization completed successfully, click Finish. If you have a
network connection to the Storwize system, the system management GUI is
displayed.If the workstation does not have a network connection to the
Storwize system, go to the workstation you will use to manage the system
and start a supported browser. Direct the browser to the management address
you specified for the system.
1
1
1
1
1
1
1
1
1
Log in with user name superuser and password passw0rd.
1
10.
1
1
Note: The 0 character in the password is a zero, not the letter O.
11. Follow the on-screen instructions to begin setting up your system.
Note: The other options that are available in the initialization tool are used to
recover the service IP address or the superuser password.
1
1
1
Adding an expansion enclosure to an existing system
When adding an expansion enclosure to an existing system, you must use the
Storwize management GUI to update the system configuration.
About this task
The management GUI requires a supported web browser (see “Web browser
requirements to access the management GUI” on page 45).
Procedure
To add an expansion enclosure to your system, complete the following steps.
1. Install support rails for the new enclosure (see “Installing the support rails” on
page 11).
2. Install the new enclosure in the rack (see “Installing the enclosures” on page
16).
3. Connect the expansion enclosure attachment cables (see “Connecting SAS
cables to expansion enclosures” on page 33).
4. Connect the power cables and wait for the SAS LEDs to illuminate (see
“Powering on the system” on page 42).
5. Start the management GUI.
6. Select Monitoring > System Details.
7. Select the system name in the tree.
8. Select Actions > Add Enclosures > Expansion only.
9. Continue to follow the on-screen instructions.
52
Storwize V3700: Quick Installation Guide
Notices
This information was developed for products and services offered in the U.S.A.
IBM may not offer the products, services, or features discussed in this document in
other countries. Consult your local IBM representative for information on the
products and services currently available in your area. Any reference to an IBM
product, program, or service is not intended to state or imply that only that IBM
product, program, or service may be used. Any functionally equivalent product,
program, or service that does not infringe any IBM intellectual property right may
be used instead. However, it is the user's responsibility to evaluate and verify the
operation of any non-IBM product, program, or service.
IBM may have patents or pending patent applications covering subject matter
described in this document. The furnishing of this document does not grant you
any license to these patents. You can send license inquiries, in writing, to:
IBM Director of Licensing
IBM Corporation
North Castle Drive
Armonk, NY 10504-1785
U.S.A.
For license inquiries regarding double-byte character set (DBCS) information,
contact the IBM Intellectual Property Department in your country or send
inquiries, in writing, to:
Intellectual Property Licensing
Legal and Intellectual Property Law
IBM Japan, Ltd.
19-21, Nihonbashi-Hakozakicho, Chuo-ku
Tokyo 103-8510, Japan
The following paragraph does not apply to the United Kingdom or any other
country where such provisions are inconsistent with local law:
INTERNATIONAL BUSINESS MACHINES CORPORATION PROVIDES THIS
PUBLICATION "AS IS" WITHOUT WARRANTY OF ANY KIND, EITHER
EXPRESS OR IMPLIED, INCLUDING, BUT NOT LIMITED TO, THE IMPLIED
WARRANTIES OF NON-INFRINGEMENT, MERCHANTABILITY OR FITNESS
FOR A PARTICULAR PURPOSE. Some states do not allow disclaimer of express or
implied warranties in certain transactions, therefore, this statement may not apply
to you.
This information could include technical inaccuracies or typographical errors.
Changes are periodically made to the information herein; these changes will be
incorporated in new editions of the publication. IBM may make improvements
and/or changes in the product(s) and/or the program(s) described in this
publication at any time without notice.
Any references in this information to non-IBM Web sites are provided for
convenience only and do not in any manner serve as an endorsement of those Web
sites. The materials at those Web sites are not part of the materials for this IBM
product and use of those Web sites is at your own risk.
© Copyright IBM Corp. 2012, 2013
53
IBM may use or distribute any of the information you supply in any way it
believes appropriate without incurring any obligation to you.
Licensees of this program who wish to have information about it for the purpose
of enabling: (i) the exchange of information between independently created
programs and other programs (including this one) and (ii) the mutual use of the
information which has been exchanged, should contact:
IBM Corporation
Almaden Research
650 Harry Road
Bldg 80, D3-304, Department 277
San Jose, CA 95120-6099
U.S.A.
Such information may be available, subject to appropriate terms and conditions,
including in some cases, payment of a fee.
The licensed program described in this document and all licensed material
available for it are provided by IBM under terms of the IBM Customer Agreement,
IBM International Program License Agreement or any equivalent agreement
between us.
Any performance data contained herein was determined in a controlled
environment. Therefore, the results obtained in other operating environments may
vary significantly. Some measurements may have been made on development-level
systems and there is no guarantee that these measurements will be the same on
generally available systems. Furthermore, some measurements may have been
estimated through extrapolation. Actual results may vary. Users of this document
should verify the applicable data for their specific environment.
Information concerning non-IBM products was obtained from the suppliers of
those products, their published announcements or other publicly available sources.
IBM has not tested those products and cannot confirm the accuracy of
performance, compatibility or any other claims related to non-IBM products.
Questions on the capabilities of non-IBM products should be addressed to the
suppliers of those products.
All statements regarding IBM's future direction or intent are subject to change or
withdrawal without notice, and represent goals and objectives only.
All IBM prices shown are IBM's suggested retail prices, are current and are subject
to change without notice. Dealer prices may vary.
This information is for planning purposes only. The information herein is subject to
change before the products described become available.
This information contains examples of data and reports used in daily business
operations. To illustrate them as completely as possible, the examples include the
names of individuals, companies, brands, and products. All of these names are
fictitious and any similarity to the names and addresses used by an actual business
enterprise is entirely coincidental.
COPYRIGHT LICENSE:
54
Storwize V3700: Quick Installation Guide
This information contains sample application programs in source language, which
illustrate programming techniques on various operating platforms. You may copy,
modify, and distribute these sample programs in any form without payment to
IBM, for the purposes of developing, using, marketing or distributing application
programs conforming to the application programming interface for the operating
platform for which the sample programs are written. These examples have not
been thoroughly tested under all conditions. IBM, therefore, cannot guarantee or
imply reliability, serviceability, or function of these programs. The sample
programs are provided "AS IS", without warranty of any kind. IBM shall not be
liable for any damages arising out of your use of the sample programs.
If you are viewing this information softcopy, the photographs and color
illustrations may not appear.
Trademarks
IBM, the IBM logo, and ibm.com® are trademarks or registered trademarks of
International Business Machines Corp., registered in many jurisdictions worldwide.
Other product and service names might be trademarks of IBM or other companies.
A current list of IBM trademarks is available on the web at Copyright and
trademark information at www.ibm.com/legal/copytrade.shtml.
Java and all Java-based trademarks and logos are trademarks or registered
trademarks of Oracle and/or its affiliates.
Linux and the Linux logo is a registered trademark of Linus Torvalds in the United
States, other countries, or both.
Microsoft, Windows, and the Windows logo are trademarks of Microsoft
Corporation in the United States, other countries, or both.
Other product and service names might be trademarks of IBM or other companies.
Electronic emission notices
This section contains the electronic emission notices or statements for the United
States and other countries.
Federal Communications Commission (FCC) statement
This explains the Federal Communications Commission's (FCC’s) statement.
This equipment has been tested and found to comply with the limits for a Class A
digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to
provide reasonable protection against harmful interference when the equipment is
operated in a commercial environment. This equipment generates, uses, and can
radiate radio frequency energy and, if not installed and used in accordance with
the instruction manual, might cause harmful interference to radio communications.
Operation of this equipment in a residential area is likely to cause harmful
interference, in which case the user will be required to correct the interference at
his own expense.
Properly shielded and grounded cables and connectors must be used in order to
meet FCC emission limits. IBM is not responsible for any radio or television
interference caused by using other than recommended cables and connectors, or by
Notices
55
unauthorized changes or modifications to this equipment. Unauthorized changes
or modifications could void the user's authority to operate the equipment.
This device complies with Part 15 of the FCC Rules. Operation is subject to the
following two conditions: (1) this device might not cause harmful interference, and
(2) this device must accept any interference received, including interference that
might cause undesired operation.
Industry Canada compliance statement
This Class A digital apparatus complies with Canadian ICES-003.
Cet appareil numérique de la classe A est conform à la norme NMB-003 du
Canada.
Australia and New Zealand Class A Statement
Attention: This is a Class A product. In a domestic environment this product
might cause radio interference in which case the user might be required to take
adequate measures.
European Union Electromagnetic Compatibility Directive
This product is in conformity with the protection requirements of European Union
(EU) Council Directive 2004/108/EC on the approximation of the laws of the
Member States relating to electromagnetic compatibility. IBM cannot accept
responsibility for any failure to satisfy the protection requirements resulting from a
non-recommended modification of the product, including the fitting of non-IBM
option cards.
Attention: This is an EN 55022 Class A product. In a domestic environment this
product might cause radio interference in which case the user might be required to
take adequate measures.
Responsible Manufacturer:
International Business Machines Corp.
New Orchard Road
Armonk, New York 10504
914-499-1900
European community contact:
IBM Deutschland GmbH
Technical Regulations, Department M372
IBM-Allee 1, 71139 Ehningen, Germany
Tele: +49 7032 15-2941
Email: lugi@de.ibm.com
Germany Electromagnetic Compatibility Directive
Deutschsprachiger EU Hinweis: Hinweis für Geräte der Klasse A EU-Richtlinie
zur Elektromagnetischen Verträglichkeit
56
Storwize V3700: Quick Installation Guide
Dieses Produkt entspricht den Schutzanforderungen der EU-Richtlinie
2004/108/EG zur Angleichung der Rechtsvorschriften über die elektromagnetische
Verträglichkeit in den EU-Mitgliedsstaaten und hält die Grenzwerte der EN 55022
Klasse A ein.
Um dieses sicherzustellen, sind die Geräte wie in den Handbüchern beschrieben zu
installieren und zu betreiben. Des Weiteren dürfen auch nur von der IBM
empfohlene Kabel angeschlossen werden. IBM übernimmt keine Verantwortung für
die Einhaltung der Schutzanforderungen, wenn das Produkt ohne Zustimmung der
IBM verändert bzw. wenn Erweiterungskomponenten von Fremdherstellern ohne
Empfehlung der IBM gesteckt/eingebaut werden.
EN 55022 Klasse A Geräte müssen mit folgendem Warnhinweis versehen werden:
“Warnung: Dieses ist eine Einrichtung der Klasse A. Diese Einrichtung kann im
Wohnbereich Funk-Störungen verursachen; in diesem Fall kann vom Betreiber
verlangt werden, angemessene Mabnahmen zu ergreifen und dafür
aufzukommen.”
Deutschland: Einhaltung des Gesetzes über die elektromagnetische
Verträglichkeit von Geräten
Dieses Produkt entspricht dem “Gesetz über die elektromagnetische Verträglichkeit
von Geräten (EMVG).” Dies ist die Umsetzung der EU-Richtlinie 2004/108/EG in
der Bundesrepublik Deutschland.
Zulassungsbescheinigung laut dem Deutschen Gesetz über die
elektromagnetische Verträglichkeit von Geräten (EMVG) (bzw. der EMC EG
Richtlinie 2004/108/EG) für Geräte der Klasse A
Dieses Gerät ist berechtigt, in übereinstimmung mit dem Deutschen EMVG das
EG-Konformitätszeichen - CE - zu führen.
Verantwortlich für die Einhaltung der EMV Vorschriften ist der Hersteller:
International Business Machines Corp.
New Orchard Road
Armonk,New York 10504
Tel: 914-499-1900
Der verantwortliche Ansprechpartner des Herstellers in der EU ist:
IBM Deutschland GmbH
Technical Regulations, Abteilung M372
IBM-Allee 1, 71139 Ehningen, Germany
Tele: +49 7032 15-2941
Email: lugi@de.ibm.com
Generelle Informationen:
Das Gerät erfüllt die Schutzanforderungen nach EN 55024 und EN 55022 Klasse
A.
People's Republic of China Class A Statement
Notices
57
Taiwan Class A compliance statement
Taiwan Contact Information
This topic contains the product service contact information for Taiwan.
f2c00790
IBM Taiwan Product Service Contact Information:
IBM Taiwan Corporation
3F, No 7, Song Ren Rd., Taipei Taiwan
Tel: 0800-016-888
Japan VCCI Council Class A statement
This explains the Japan Voluntary Control Council for Interference (VCCI)
statement.
Japan Electronics and Information Technology Industries
Association Statement
This explains the Japan Electronics and Information Technology Industries
Association (JEITA) statement for less than or equal to 20 A per phase.
58
Storwize V3700: Quick Installation Guide
jjieta1
jjieta2
This explains the JEITA statement for greater than 20 A per phase.
Korean Communications Commission Class A Statement
This explains the Korean Communications Commission (KCC) statement.
Russia Electromagnetic Interference Class A Statement
rusemi
This statement explains the Russia Electromagnetic Interference (EMI) statement.
European Contact Information
This topic contains the product service contact information for Europe.
European Community contact:
IBM Technical Regulations
Pascalstr. 100, Stuttgart, Germany 70569
Tele: 0049 (0)711 785 1176
Fax: 0049 (0)711 785 1283
Email: mailto: tjahn @ de.ibm.com
Taiwan Contact Information
This topic contains the product service contact information for Taiwan.
IBM Taiwan Product Service Contact Information:
IBM Taiwan Corporation
3F, No 7, Song Ren Rd., Taipei Taiwan
Tel: 0800-016-888
Notices
59
f2c00790
60
Storwize V3700: Quick Installation Guide
Index
Numerics
1 Gbps iSCSI 4-port host interface card
Ethernet cables 36
installing 24
10 Gbps iSCSI-FCoE 2-port host interface
card
fibre cables 37
installing 22
8 Gbps Fibre Channel 4-port host
interface card 20, 39
A
air flow
42
B
browsers
45
C
cache memory upgrade, 8 GB 27
Canadian electronic emission notice
caution ix
caution notices x
comments xix
contact information
European 59
Taiwan 58, 59
control enclosure
data ports 7
disk drives 32
installing 16, 17
location guidelines 10
node canister
closing 30
installing 30
opening 18
removing 18
options 17
power cords 42
cooling 42
56
F
FCC (Federal Communications
Commission) electronic emission
notice 55
Federal Communications Commission
(FCC) electronic emission notice 55
feedback xix
fibre cables 37
Fibre Channel
cables 39
host interface card 20
D
danger ix
danger notices xii
Deutschsprachiger EU Hinweis
disk drives 32
installing 32
large form factor 5
small form factor 5
56
G
Germany electronic emission compliance
statement 56
H
E
electronic emission notices
Deutschsprachiger EU Hinweis
European Union (EU) 56
© Copyright IBM Corp. 2012, 2013
electronic emission notices (continued)
Federal Communications Commission
(FCC) 55
Germany 56
Industry Canada 56
Japanese Voluntary Control Council
for Interference (VCCI) 58
Korean 59
New Zealand 56
People's Republic of China 57
Taiwan 58
electronic emissions notices 58
EMC statement, People's Republic of
China 57
environmental notices ix, xvi
environmental requirements 10
Ethernet
cables
for 1 Gbps iSCSI 4-port host
interface cards 36
for system management 36
ports 7
switch 36, 37
European contact information 59
European Union (EU), EMC Directive
conformance statement 56
expansion canister
data ports 8
LEDs 42
expansion enclosure
adding to an existing system 52
attachment cables 33
installing 16
location guidelines 10
power cords 42
56
hardware components
identifying 6
list 5
help xx
host
attachment cables 39
host interface card
1 Gbps iSCSI 4-port 24
10 Gbps iSCSI-FCoE 2-port 22
8 Gbps Fibre Channel 4-port 20, 39
SAS 4-port 26
I
IEC 60950-1 ix
information center xvii
information help xx
initializing the system
Apple Macintosh 49
Linux 51
Microsoft Windows 47
J
Japan Electronics and Information
Technology Industries Association
Statement 58
Japanese electronic emission notice 58
K
Korean electronic emission statement
59
L
labels ix
LEDs
expansion canister 42
node canister 42
location guidelines 10
M
management GUI
adding an expansion enclosure 52
web browser requirements 45
memory upgrade, 8 GB 27
N
New Zealand electronic emission
statement 56
node canister
8 GB cache memory upgrade 27
closing 30
Ethernet cables 36
fibre cables 37
Fibre Channel cables 39
host interface card
1 Gbps iSCSI 4-port 24
10 Gbps iSCSI-FCoE 2-port 22
8 Gbps Fibre Channel 4-port 20
61
node canister (continued)
host interface card (continued)
SAS 4-port 26
installing 30
LEDs 42
opening 18
options, installing 17
removing 18
notices ix
environmental ix, xvi
safety ix
USB flash drive (continued)
locating 8
user name 46
W
web browsers
websites xix
P
packing slip 5
password 46
People's Republic of China, electronic
emission statement 57
power cords 42
powering on the system 42
R
rails 11, 16
reader feedback xix
related information xvii
S
safety ix
caution notices x
danger notices xii
environmental notices ix
safety information labels ix
safety notices ix
SAS 4-port host interface card
installing 26
SAS cables 33, 39
send a comment xix
SFP transceiver
10 Gbps iSCSI-FCoE 2-port host
interface card 22
8 Gbps Fibre Channel 4-port host
interface card 20
static-sensitive devices xv
Storwize V3700
safety notices x, xii
Storwize V3700 library
related publications xvii
T
Taiwan
contact information 58, 59
electronic emission notice 58
technical assistance xx
trademarks 55
U
USB flash drive
initializing the system
Apple Macintosh 49
Linux 51
Microsoft Windows 47
62
Storwize V3700: Quick Installation Guide
45
Part Number: 00AR171
GC27-4219-01
(1P) P/N: 00AR171
Printed in USA
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project