Herth+Buss Multifunction test lamp Bedienhinweis
Below you will find brief information for Multifunction Test Lamp. This device allows testing automotive electrical systems (12-24V) without reconnecting the battery. It features polarity indication, an illuminated LCD, an integrated LED light, and allows for component activation with positive or negative voltage. It also includes a continuity test, high-voltage and frequency measurement capabilities, and functionality for trailer lighting.
Advertisement
Advertisement
ELPARTS
Bedienhinweis
Spannungs-/Strom-Meßgerät,
Multifunktionsprüflampe
Bedienhinweis 95980781
Einleitung
Die Mulitfunktionsprüflampe ist ein Gerät zur Prüfung elektrischer Anlagen von Kraftfahrzeugen aller Art im Bereich von 12 bis 24
Volt. Um die Diagnosezeit zu verkürzen, ist die Multifunktionsprüflampe so konstruiert, dass die Anlage geprüft werden kann, ohne dass zwischen Autobatterie und Prüfkomponenten ein erneuter Anschluss hergestellt werden muss.
Das Gerät verfügt über folgende Funktionen
1. mit optischer Polaritätsanzeige
2. gut ablesbares und beleuchtetes LCD-
Display
3. Integrierte LED-Leuchte
4. Durchgangstest mittels Hilfsklemme
5. Betreiben von elektrischen Komponenten und Baugruppen
6. Kontaktlose Hochspannungs- und Frequenzmessung an Zündleitungen
7. Feststellung von schlechten Massekontakten
8. Gut geeignet zur Fehlersuche an Trailern mittels Kabelverlängerung
9. Kurzschlussgesichert
10. Lieferung incl. Prüfspitzenverlängerung,
Kabelverlängerung und Stecker für die Zigarettenzünderdose in kompakten Werkstattkoffer fung keine Sicherungen verschwendet. Das
Verlängerungskabel ist lang genug, damit der Techniker die gesamte Anlage des Autos prüfen kann.
Beleuchtung
Da ein Teil der Prüfschaltung bei der Prüfung beschattet ist, verfügt die Multifunktionsprüflampe zur Erleichterung der Arbeit über eine integrierte LED-Leuchte. Die Beleuchtung schaltet sich automatisch ein, wenn der
Techniker die Mulifunktionsprüflampe an die
Autobatterie anschließt.
Wichtig
Bitte lesen Sie vor der Benutzung der Multifunktionsprüflampe die Anleitung durch.
Warnung
Wird die Mulitfunktionsprüflampe mit Strom versorgt, können Funken entstehen, wenn die Prüfspitze mit Masse oder bestimmten
Schaltungen in Kontakt kommt. Die Multifunktionsprüflampe soll deshalb nicht in der
Nähe von brennbaren Gegenständen benutzt werden. Die Mulitfunktionsprüflampe sollte auch nicht mit 110/220 Volt Hausspannung benutzt werden. Es ist nur für Systeme mit 6 bis 24 Volt bestimmt.
Die Multifunktionsprüflampe enthält zu
Prüfzwecken und der Sicherheit halber einen Kurzschlussschutz, mit dem auch der
Erdungsanschluss ohne Spannungsabfallprüfungen kontrolliert werden kann. Der
Kurzschlussschutz enthält die automatische
Sicherung, so dass der Techniker bei der Prü-
Beispiel:
1. Die Komponenten bei ausgeschalteter
Elektrik des Autos aktivieren
2. Die Komponenten nur mit positiver Spannung aktivieren
3. Die Komponenten nur mit negativer
Spannung aktivieren
4. Prüfung der Anhängerbeleuchtung www.herthundbuss.com 2
Bedienhinweis 95980781
3
Wenn der Leistungsschalter des Kurzschlussschutzes ausgelöst ist, berühren Sie bitte nicht sofort den Messfühler oder die Messfühlerverlängerung mit der Hand. Messfühler und Messfühlerverlängerung sind nach
Auslösung des Leistungsschalters sehr heiß.
Pol in Berührung kommt, leuchtet die rote
LED.
2. Wenn die Prüfspitze mit dem negativen
Pol in Berührung kommt, leuchtet die grüne LED.
3. Wenn die Prüfspitze mit der Leerlaufschaltung in Berührung kommt, leuchtet keine LED.
Betriebsarten
Die Multifunktionsprüflampe hat vier Betriebsarten, die durch Drücken des Betriebsartenschalters und Durchlaufen der Betriebsarten gewählt werden können.
Betriebsart
1. Spannungsmesser, Messbereich: 0 bis 24 V
2. Suche ausgefallener Zylinder
3. Frequenzmessung der Zündimpulse
4. Spannungsspitzenerkennung
Stromanschluss
1. Die schwarze Stromklemme an den negativen Pol der Autobatterie anschließen.
2. Die rote Stromklemme an den positiven
Pol der Autobatterie anschließen.
Selbsttest
Wenn die Multifunktionsprüflampe ordnungsgemäß funktioniert, sollte der Zustand wie folgt sein:
1. Wenn der Techniker den Polaritätsschalter nach vorn schiebt (zur positiven Seite), sollte die rote LED leuchten.
2. Wenn der Techniker den Polaritätsschalter nach hinten schiebt (zur negativen Seite), sollte die grüne LED leuchten.
Prüfung der Polarität
1. Wenn die Prüfspitze mit dem positiven
Prüfung der Leitfähigkeit
Durch Verwendung der Prüfspitze mit der
Masseprüfleitung kann der Techniker die
Leitfähigkeit zwischen Kabeln oder Komponenten prüfen, die nicht an die elektrische Anlage des Autos angeschlossen sind.
Wird der Strom zwischen den Drähten oder
Komponenten geleitet, sollte die grüne LED leuchten.
Die Komponenten bei ausgeschalteter elektrischer Anlage des Autos aktivieren. Durch
Verwendung der Prüfspitze mit der Masseprüfleitung kann der Techniker die Prüfkomponenten bei ausgeschalteter elektrischer
Anlage des Autos aktivieren. Diese Funktion kann z. B. zum Prüfen von Leuchten, Kühlgebläsen, Kraftstoffpumpen usw. genutzt werden. Dazu soll bitte wie folgt vorgegangen werden:
1. Die Masseprüfleitung an den negativen
Pol der Komponenten anschließen
2. Die Prüfspitze an den positiven Pol der
Komponenten anschließen. Wenn die grüne LED leuchtet, ist die geprüfte Komponente leitfähig.
3. Wenn die grüne LED aufleuchtet, drücken
Sie bitte den Polaritätsschalter nach vorn und lassen ihn kurz darauf wieder los.
Bedienhinweis 95980781
Wenn die LED von grün auf rot umschaltet, kann die Prüfung fortgesetzt werden. Wenn die grüne LED erlischt und die rote LED aufleuchtet oder der Leistungsschalter des Kurzschlussschutzes ausgelöst wird, ist die Multifunktionsprüflampe überlastet. Das kann folgende Ursachen haben:
1. Die Komponente hat einen Kurzschluss oder ist direkt an Masse / den negativen
Pol angeschlossen.
2. Die Komponente ist eine Hochstromkomponente.
Wenn der Leistungsschalter des Kurzschlussschutzes ausgelöst wird, kommt er innerhalb von maximal 60 Sekunden automatisch wieder zur Ruhe.
Nur Komponenten mit positiver Spannung aktivieren
Wenn der Techniker die Komponenten prüft, kann er mithilfe der Multifunktionsprüflampe die geprüften Komponenten mit positiver
Spannung versorgen. Dazu soll bitte wie folgt vorgegangen werden:
1. Die Prüfspitze an den positiven Pol der
Komponenten anschließen. Wenn die grüne LED leuchtet, ist die geprüfte Komponente leitfähig.
2. Wenn die grüne LED aufleuchtet, drücken
Sie bitte den Polaritätsschalter nach vorn und lassen ihn kurz darauf wieder los.
3. Wenn die grüne LED aufleuchtet, drücken
Sie bitte den Polaritätsschalter nach vorn und lassen ihn kurz darauf wieder los.
Wenn die LED von grün auf rot umschaltet, kann die Prüfung fortgesetzt werden. Wenn die grüne LED erlischt und die rote LED aufleuchtet oder der Leistungsschalter des Kurzschlussschutzes ausgelöst wird, ist die Multifunktionsprüflampe überlastet. Das kann folgende Ursachen haben:
1. Die Komponente hat einen Kurzschluss oder ist direkt an Masse / den negativen
Pol angeschlossen.
2. Die Komponente ist eine Hochstromkomponente.
Wenn der Leistungsschalter des Kurzschlussschutzes ausgelöst wird, kommt er innerhalb von maximal 60 Sekunden automatisch wieder zur Ruhe.
Bitte diese Funktion mit dem schematischen und richtigen Prüfverfahen ausführen. Willkürliches Anlegen von Spannung kann die Komponenten beschädigen. Mit der Prüfspitze positive Spannung anlegen.
Das kann bei der Komponentendiagnose hilfreich sein. Werden die Komponenten mit
Strom versorgt, bitte den Schalter drücken, www.herthundbuss.com 4
Bedienhinweis 95980781
5 bevor die Prüfspitze mit den Komponenten in Berührung kommt. In diesem Fall wird die
Lichtbogenbildung zwischen der Spitze und der Komponente anstatt am Schalter erfolgen. So kann die Lebensdauer des Schalters verlängert werden.
ausführen. Willkürliches Anlegen von Spannung kann die Komponenten beschädigen.
Mit der Prüfspitze negative Spannung anlegen. Das kann bei der Komponentendiagnose hilfreich sein.
Nur die Komponenten mit negativer Spannung aktivieren
Neben dem Anlegen der positiven Spannung kann der Techniker mithilfe der Mulitfunktionsprüflampe die Komponenten auch mit negativer Spannung versorgen.
Das geht folgendermaßen:
1. Die Prüfspitze an den negativen Pol der
Komponente anschließen. In dieser Phase sollte die rote LED leuchten, wenn die
Komponente richtig funktioniert.
2. Den Polaritätsschalter nach hinten schieben und schnell loslassen. Wenn die LED von rot auf grün umschaltet, kann mit der
Prüfung fortgefahren werden. Wenn die grüne LED erlischt oder der Leistungsschalter des Kurzschlussschutzes ausgelöst wird, ist die Multifunktionsprüflampe
überlastet. Das kann folgende Ursachen haben:
3. Die Komponente hat einen Kurzschluss oder ist direkt an Masse / den negativen
Pol angeschlossen.
4. Die Komponente ist eine Hochstromkomponente.
Prüfung der Anhängerbeleuchtung
Zum Prüfen der Anhängerbeleuchtung müssen Sie wie folgt vorgehen:
1. Masseprüfkabel an die Anhängermasse anschließen.
2. Die Prüfspitze an den Anhängerausgang anschließen und Polaritätsschalter nach vorn schieben. Nun kann der Techniker die Funktion der Anhängerbeleuchtung
überprüfen.
Wenn der Leistungsschalter des Kurzschlussschutzes ausgelöst wird, kommt er innerhalb von maximal 60 Sekunden automatisch wieder zur Ruhe. Bitte diese Funktion mit dem schematischen und richtigen Prüfverfahen
Spannungsprüfung
Durch Verwendung der Multifunktionsprüflampe kann der Techniker mit der Masseprüfleitung die Spannung der Schaltung
überprüfen. Bei der Spannungsprüfung nicht den Polaritätsschalter drücken.
Bedienhinweis 95980781
1. Wenn die Prüfspitze des Messfühlers
„schwimmt“ (keine Schaltung berührt), erlöschen die rote und die grüne LED.
Wenn die Prüfspitze eine positive Schaltung berührt, leuchtet die LED mit dem roten positiven Zeichen „+“ und der
Spannungsmesser zeigt den Spannungswert mit einer Genauigkeit von 1/1 Volt an.
2. Wenn die Prüfspitze eine negative Schaltung berührt, leuchtet die LED mit dem grünen negativen Zeichen „-“.
Frequenzmessung der Hochspannungszündimpulse
Die Multifunktionsprüflampe kann die Frequenz der Hochspannungszündimpulse messen. Wird die Messfühlerspitze neben ein Zündkerzenkabel gesetzt (NICHT direkt messen), kann das Gerät durch kapazitive
Kopplung die Hochspannungszündimpulse messen. Gleichzeitig wird der Spannungswert angezeigt.
Suche fehlende Zylinder
Wird die Messfühlerspitze neben ein Zündkerzenkabel gesetzt (NICHT direkt messen), kann das Gerät durch kapazitive Kopplung die Hochspannungszündimpulse messen.
Gleichzeitig wird der Spannungswert angezeigt. Durch Kontrolle jedes Zündkerzenkabels auf diese Weise können fehlende Zylinder gefunden werden.
Warnung
Prüfspitze des Messfühlers nicht direkt mit der sekundären Zündschaltung in Kontakt bringen.
Spitzenerkennung
Der Benutzer kann den Spitzenschwellenwert vorwählen und dann eine Schaltung anschließen. Ist die Spannung höher als der
Schwellenwert, ertönt ein Alarmsignal. Den
Spitzenschwellenwert in Spannungsschritten von 0,5 bis 1,0, bis 2,0, bis 5,0, bis 10,0, bis 48,0 und wieder zurück bis 0,5 einstellen.
Warnung: Prüfspitze des Messfühlers nicht direkt mit der sekundären Zündschaltung in
Kontakt bringen.
www.herthundbuss.com 6
7
Introduction
The Multi functional auto tester is an equipment used to test the automotive electrical system within 12 - 24 volts. In order to save the testing hours for the automotive electrical system, The Multi functional auto tester is designed to testing the system without reconnection between the vehicle battery and the testing components, and it contains the following functions:
1. Determine the polarity and circuit circumstance (short! open).
2. Activating the components with positive or negative current without jumper wire.
3. Testing the voltage and continuity of the circuit.
4. Illumination.
5. Locate missing cylinders.
6. Measuring frequency of the high-tension ignition pulses and we could calculate the rotational speed of engine according to the measured frequency.
7. Peak detection.
8. Testing the voltage of the circuit and the voltage reading will be indicated on the
LCD display within 1/1 oth of a volt.
have to search for ground connection constantly.
Illumination
Since some of the testing circuit will be shadowed during the testing, the multi functional auto tester provides the illumination for you convenience. The illumination will automatically turned on as the technician hook up the multi functional auto tester with vehiele battery.
Important
Please read the instruction before you start to use the multi functional auto tester.
Warning
When current is provided to the the multi functional auto tester , spark may be occurred when the tip contacts with ground or certain circuits. Therefore please do not operate the multi functional auto tester around flammable. And please do not operating the multi functional auto tester with 110/220 volt house voltage as it is only for 12 - 24 volt systems.
Eventually, for the testing and safety purpose, the multi functional auto tester contains short-circuit protection, which can also check the ground connection without voltage drop tests. The short-circuit protection system contains the recoverable fuse, and so the technician will not waste the fuses during the testing. The extension cable with the multi functional auto tester is long enough for a technician to test the who ie system for the vehicle, therefore, the technician do not
Getting to know your Auto Tester
If you use the the multi functional auto tester
‚s „Polar switch“ to test, please add extended-probe to the the multi functional auto tester ‚s probe.
For example:
1. Activate the components with automotive electrical system disconnected.
2. Activate the components with positive voltage only.
3. Activate the components with negative voltage only.
4. Trailer light Test.
If the circuit breaker of the short circuit protection has tripped, please do not contact your hand to the probe and extended-probe immediately.Because the probe and extended-probe is very hot after the circuit breaker has tripped.
Mode instruction
The auto tester have four modes, the four modes can be selected by depressing the mode select button and cycling through each one.
2. Green LED should be on when the technician push the polar switch backward.
(toward the negative side).
Polarity Test
1. If the the multi functional auto tester tip is contacting with positive pole, the red LED will be on.
2. If the the multi functional auto tester tip is contacting with negative pole, the green
LED will be on.
3. If the the multi functional auto tester tip is contacting with open circuit, neither LED will be on.
Mode
1. Voltage meter, measuring range: Ov-60v.
2. Locate missing Cylinders.
3. Measuring frequcuency of the ignition pulses.
4. Peak Detection.
Power Connection
1. Hook up the black power clip to the negative of the vehicle battery.
2. Hook up the red power clip to the positive of the vehicle battery.
Self-Test
If the the multi functional auto tester is working correctly, the condition should be followed:
1. Red LED should be on when the technician push the polar switch forward (toward the positive side).
Conductivity Test
By using the multi functional auto tester tip assisting with ground test lead, technician can test the conductivity between wires or components wh ich has been disconnected from the vehicle electrical system. If the current is conductible between wires or components, the green LED should be on.
Activate the components with automotive electrical system disconnected By assisting the multi functional auto tester tip with the ground test lead, technician can activate the testing components with auto motive electrical system been disconnected. This function can be used to test light, cooling fans, and fuel pumps etc. To do this, please follow the procedure:
1. Connect the ground test lead with the negative pole of the components
2. Contact the multi functional auto tester tip with the positive pole of the components. If the green LED is on, it means the testing component is conductible.
www.herthundbuss.com 8
9
3. As the green LED goes on, please press the polar switch forward and then release it quickly.
If the LED goes from green to red, you may proceed further testing. If the green LED turns off and red LED doesn‘t turns on, or if the circuit breaker of the short circuit protection tripped, it means the multi functional auto tester has overloaded. This may due to the following reasons:
1. The component is short circuit or it has been connected to the ground/ negative pole directly.
2. The component is a high current component.
If the circuit breaker of the short circuit protection has tripped, it will auto-rest within no more than 60 seconds.
Activate components with positive voltage only
When technician tests the components, technician can use the multi functional auto tester to provide positive voltage to the testing components. To do this, pleas follow the procedure:
1. Contact the the multi functional auto tester tip with the positive pole of the components. If the green LED is on ,it means the testing component is conductible.
As the green LED goes on, please press the polar switch forward and then release it quickly. If the LED goes from green to red, you may proceed further testing. If the green
LED turns off and red LED doesn‘t turns on, or if the circuit breaker of the short circuit protection tripped, it means the multi functional auto tester has overloaded. This may due to the following reasons:
2. The component is short circuit or it has been connected to the ground/negative pole directly.
3. The component is a high current component.
If the circuit breaker of the short circuit protection has tripped, it will auto-rest within no more than 60 seconds.
Please operate this function with schematic and correct testing procedure because applying voltage arbitrarily may cause damage to components.
Use tip to apply positive voltage, which can be helpful to diagnose the components.
When applying current to the components, please push the switch before contact the tip with the components. In this case, the arcing will take place between the tip and the component instead of the switch. And so it can increase the life time of the switch.
Activate the components with negative voltage only
Apart from applying the positive voltage, technician can also use the multi functional auto tester to provide negative voltage to the components. The procedures are as follow:
1. Contact the the multi functional auto tester tip to the negative pole of the component; at this stage, the red LED should be on if the component working correctly.
2. Push the polar switch backward and release it quickly. If the LED goes from red to green, you may proceed further test. If the green LED goes off or the circuit breaker of the short circuit protection tripped, it means the multi functional auto tester has over loaded.This may cause by the following reasons:
3. The component is short circuit or it has been connected to the groundl negative pole directly.
4. The component is a high current component.
If the circuit breaker of the short circuit protection has tripped, it will auto-rest within no more than 60 seconds. Please operate this function with schematic and correct testing procedure because applying voltage arbitrarily may cause damage to components. Use tip to apply negative voltage, which can be helpful to diagnose the components
2. Probe the tip to the outlet of the trailer; push the polar switch forward, then technician can diagnose the function of the trailer light.
Voltage Test
Technician can also use the multi functional auto tester assisting with ground test lead to test the voltage of the circuit. However, during the voltage test, pleas do not push the polar switch.
1. If the probe tip is floating (not contacting a circuit),the red and green LED turn off.
2. If the the multi functional auto tester contact the probe tip to a positive circuit. The red positive sign“+“ LED will light and the voltmeter displays the voltage reading within 1/1 Oth of a volt.
3. If the the multi functional auto tester contact the probe tip to a negative circuit. The green negative sign“-“ LED will light.
Trailer Light Test
To test the trailer light, you need to follow the procedure:
1. Connect the ground test lead to trailer ground.
Locate missing cylinders
Placing the the multi functional auto tester probe tip next to a sparking wire(DON‘T probing it directly), through capacitive coupling, www.herthundbuss.com 10
the the multi functional auto tester can seses the high-tension ignigion pulses at the same time displaya voltage reading. By monitoring each plug wire in this way you can locate missing cylinders.
The measurement is impossible if all the high-tension wires are not bundled together since the distance between the detection head and each high-tension wire differs.
1. Specifications Applicable engine type: gasoline engine.
2. 2-cycle (1 ,2,3,4-cylinders).
3. 4-cycle(1 ,2,3,4,5,6,8, 12-cylinders) Detection method: ignition spark noise detection. Detection object: High-tension wire or ignition cord.
4. Calculating the rotational speed of engine. We could calculate the rotational speed of engine according to the measured frequency. The calculation format is as folIows: n=60xfx1/PR.
Warning: Do not contact probe tip directly to the secondary ignition circuit.
Measuring the frequency of the high-tension ignition pulses
The the multi functional auto tester can measure the frequency of the high-tension ignition pulses.Placing the multi functional auto tester probe tip next to a sparking wire(DO
NOT probing it directly), through capacitive coupling, the the multi functional auto tester can seses the high-tension ignigion pulses at the same time displaya frequency reading.
As shown in the figure A,B, bring the detection head close to the high-tension wire that connect the distributor and the ignition coil, or to the place where all the high-tension wires of the cylinders are bundled together.
1 Multi-cylinder gasoline engine without distributor. Bring the detection head elose to the place where the high-tension wire of each cylinder is bundled together.
The „n“denotes the rotational speed of engine.
The „f‘denotes the frequency of high-tension ignition pulses.
The „PR“denotes the ratio coefficient between the „f‘and the „n“.
The number of „PR“,types of engines are as folIows:
Warning: Do not contact probetip directly to the secondary ignition circuit.
Peak Detection
The operator can pre-select the peak threshold levels,and then contact a circuit if the voltage greater than the threshold, you can hear the alarm audio.
The peak threshold voltage setting loop incrementally from 0.5, to 1.0, to 2.0, to 5.0 , to 10.0 ,to 48.0 and return back to 0.5 again.
11
Introduction
La lampe témoin multifonction est un appareil pour contrôler les installations électriques de véhicules automobiles de toute sorte dans une plage allant de 12 à 24 volts.
Pour diminuer la durée du diagnostic, la lampe témoin multifonction est construite de façon à ce que l’installation puisse être contrôlée sans une nouvelle mise en place d’un raccordement entre la batterie du véhicule et les éléments à contrôler.
L’appareil dispose des fonctions suivantes :
1. Avec affichage optique de polarité
2. Écran ACL à bonne lisibilité et éclairé
3. Ampoule DEL intégrée
4. Test de continuité à l’aide de la pince auxiliaire
5. Faire fonctionner les composants et les modules électriques
6. Mesure de haute tension et métrologie des fréquences sans contact sur les câbles d’allumage
7. Détection de mauvais contacts de masse
8. Idéal pour la recherche de défaut sur les remorques à l’aide d’une rallonge de câble
9. Sécurisé contre les courts-circuits
10. Livré avec rallonge de la pointe d’essai, rallonge de câble et prise pour l’allumecigare dans une caisse à outils cuits comporte un fusible automatique. Ainsi le technicien ne gaspille pas de fusibles lors du contrôle. Le câble à rallonge est assez long pour permettre au technicien de contrôler l’ensemble de l’installation du véhicule.
Éclairage
Étant donné qu’une partie du circuit de contrôle se trouve dans l’ombre pendant le contrôle, la lampe témoin multifonction dispose d’un voyant DEL intégré pour faciliter le travail. L’éclairage s’allume automatiquement lorsque le technicien branche la lampe témoin multifonction sur la batterie du véhicule.
Important
Veuillez lire la notice avant d’utiliser la lampe témoin multifonction.
Avertissement
Lorsque la lampe témoin multifonction est alimentée en électricité, il peut y avoir des
étincelles lorsque la pointe d’essai entre en contact avec la masse ou certains circuits.
La lampe témoin multifonction ne doit donc pas être utilisée à proximité d’objets inflammables. La lampe témoin multifonction ne doit également pas être utilisée sur le courant domestique de 110/220 volts. Elle est uniquement adaptée à des systèmes de 6 à
24 volts.
Pour des raisons de contrôle et de sécurité, la lampe témoin multifonction est équipée d’une protection contre les courts-circuits avec laquelle le branchement de mise à la terre peut être contrôlé sans contrôles de baisses de tension. La protection contre les courts-cir-
Exemple :
1. Activer les composants lorsque le système électrique du véhicule est arrêté
2. Activer les composants uniquement avec un courant positif www.herthundbuss.com 12
3. Activer les composants uniquement avec un courant négatif
4. Contrôle de l’éclairage de la remorque
2. Lorsque le technicien pousse l’interrupteur de polarité vers l’arrière (vers le côté négatif ), la DEL verte doit s’allumer.
Lorsque le disjoncteur de la protection contre les courts-circuits est déclenché, ne pas toucher immédiatement le capteur ou la rallonge du capteur avec la main. Après un déclenchement du disjoncteur, le capteur et la rallonge du capteur sont très chaud.
Modes de fonctionnement
La lampe témoin multifonction a quatre modes de fonctionnement que vous pouvez sélectionner en appuyant la touche des modes de fonctionnement puis en faisant défiler les modes.
Contrôle de polarité
1. Lorsque la pointe d’essai entre en contact avec le pôle positif, la DEL rouge s’allume.
2. Lorsque la pointe d’essai entre en contact avec le pôle négatif, la DEL verte s’allume.
3. Lorsque la pointe d’essai entre en contact avec le circuit de ralenti, aucune DEL ne s’allume.
Mode de fonctionnement
1. Voltmètre, plage de mesure : 0 à 24 volts
2. Recherche de cylindres en panne
3. Métrologie des fréquences des impulsions d’allumage
4. Reconnaissance des pics de tension
Raccordement électrique
1. Raccorder la pince de connexion noire au pôle négatif de la batterie du véhicule.
2. Raccorder la pince de connexion rouge au pôle positif de la batterie du véhicule.
Autodiagnostic
Lorsque la lampe témoin multifonction fonctionne correctement, les conditions doivent
être comme suit :
1. Lorsque le technicien pousse l’interrupteur de polarité vers l’avant (vers le côté positif), la DEL rouge doit s’allumer.
Contrôle de conductibilité
En utilisant la pointe d’essai avec le câble de contrôle de la masse, le technicien peut contrôler la conductibilité entre les câbles ou les composants qui ne sont pas raccordés à l’installation électrique du véhicule. Lorsque le courant passe entre les câbles ou les composants, la DEL verte doit s’allumer.
Activer les composants lorsque le système
électrique du véhicule est arrêté. En utilisant la pointe d’essai avec le câble de contrôle de la masse, le technicien peut activer les
éléments à contrôler alors que l’installation
électrique du véhicule est arrêtée. Cette fonction peut être utilisée p. ex. pour contrôler les feux, les ventilateurs de refroidissement, les pompes à carburant. Pour cela, veuillez procéder comme suit :
1. Raccorder le câble de contrôle de la masse au pôle négatif des composants.
2. Raccorder la pointe d’essai au pôle positif des composants. Si la DEL verte s’allume, le composant contrôlé est conducteur.
3. Lorsque la DEL verte s’allume, veuil-
13
lez pousser l’interrupteur de polarité vers l’avant et le relâcher peu de temps après.
Lorsque la DEL passe de vert à rouge, le contrôle peut être poursuit. Si la DEL verte s’éteint et que la DEL rouge s’allume ou que le disjoncteur de la protection contre les courts-circuits est déclenché, la lampe témoin multifonction est en surcharge. Ceci peut avoir les raisons suivantes :
1. Le composant a un court-circuit ou il est directement raccordé à la masse/au pôle négatif.
2. Le composant est un composant sous haute tension.
Lorsque le disjoncteur de la protection contre les courts-circuits est déclenché, il se détend de nouveau automatiquement en l’espace de 60 secondes au maximum.
Activer uniquement les composants à tension positive
Lorsque le technicien contrôle les composants, il peut alimenter les composants contrôlés en tension positive à l’aide de la lampe témoin multifonction. Pour cela, veuillez procéder comme suit :
1. Raccorder la pointe d’essai au pôle positif des composants. Si la DEL verte s’allume, le composant contrôlé est conducteur.
2. Lorsque la DEL verte s’allume, veuillez pousser l’interrupteur de polarité vers l’avant et le relâcher peu de temps après.
3. Lorsque la DEL verte s’allume, veuillez pousser l’interrupteur de polarité vers l’avant et le relâcher peu de temps après.
Lorsque la DEL passe de vert à rouge, le contrôle peut être poursuit. Si la DEL verte s’éteint et que la DEL rouge s’allume ou que le disjoncteur de la protection contre les courts-circuits est déclenché, la lampe témoin multifonction est en surcharge. Ceci peut avoir les raisons suivantes :
1. Le composant a un court-circuit ou il est directement raccordé à la masse/au pôle négatif.
2. Le composant est un composant sous haute tension.
Lorsque le disjoncteur de la protection contre les courts-circuits est déclenché, il se détend de nouveau automatiquement en l’espace de 60 secondes au maximum.
Veuillez effectuer cette fonction avec le procédé de contrôle correct et schématique. La mise sous tension arbitraire peut endommager les composants. Mettre sous tension positive avec la pointe d’essai. Ceci peut être utile pour le diagnostic des composants.
Lorsque les composants sont mis sous tension, veuillez appuyer sur l’interrupteur www.herthundbuss.com 14
avant que la pointe d’essai entre en contact avec le composant. Dans ce cas, l’arc électrique se produira entre la pointe et le composant plutôt qu’à l’interrupteur. La durée de vie de l’interrupteur peut ainsi être prolongée.
de contrôle correct et schématique. La mise sous tension arbitraire peut endommager les composants. Mettre sous tension négative avec la pointe d’essai. Ceci peut être utile pour le diagnostic des composants.
Activer uniquement les composants à tension négative
À l’aide de la lampe témoin multifonction, le technicien peut, en plus de la mise sous tension positive, également mettre sous tension négative.
Procéder comme suit:
1. Raccorder la pointe d’essai au pôle négatif du composant. Lors de cette étape, la
DEL rouge doit s’allumer si le composant fonctionne correctement.
2. Pousser l’interrupteur de polarité vers l’arrière et relâcher rapidement. Lorsque la DEL passe de rouge à vert, le contrôle peut être poursuit. Si la DEL verte s’éteint ou que le disjoncteur de la protection contre les courts-circuits est déclenché, la lampe témoin multifonction est en surcharge. Ceci peut avoir les raisons suivantes :
3. Le composant a un court-circuit ou il est directement raccordé à la masse/au pôle négatif.
4. Le composant est un composant sous haute tension.
Contrôle de l’éclairage de la remorque
Pour contrôler l’éclairage de la remorque, vous devez procéder comme suit :
1. Raccorder le câble de contrôle de la masse à la masse de la remorque.
2. Raccorder la pointe d’essai à la sortie pour la remorque et pousser l’interrupteur de polarité vers l’avant. Le technicien peut alors contrôler le fonctionnement de l’éclairage de la remorque.
Lorsque le disjoncteur de la protection contre les courts-circuits est déclenché, il se détend de nouveau automatiquement en l’espace de 60 secondes au maximum. Veuillez effectuer cette fonction avec le procédé
Contrôle de tension
En utilisant la lampe témoin multifonction, le technicien peut contrôler la tension du circuit avec le câble de contrôle de la masse.
Lors du contrôle de tension, ne pas activer l’interrupteur de polarité.
15
1. Lorsque la pointe d’essai du capteur ne touche aucun circuit, la DEL rouge et la DEL verte s’éteignent. Lorsque la pointe d’essai entre en contact avec un circuit positif, la DEL avec le signe positif rouge « + » s’allume et le voltmètre indique la tension avec une précision de
1/1 volt.
2. Lorsque la pointe d’essai entre en contact avec un circuit négatif, la DEL avec le signe négatif vert « - » s’allume.
Métrologie des fréquences des impulsions d’allumage haute tension
La lampe témoin multifonction peut mesurer la fréquence des impulsions d’allumage haute tension. Lorsque la pointe du capteur est positionnée à côté d’un câble d’allumage
(NE PAS mesurer directement), l’appareil peut mesurer les impulsions d’allumage haute tension par couplage capacitif. La tension est indiquée en même temps.
Recherche de cylindres manquants
Lorsque la pointe du capteur est positionnée
à côté d’un câble d’allumage (NE PAS mesurer directement), l’appareil peut mesurer les impulsions d’allumage haute tension par couplage capacitif. La tension est indiquée en même temps. En contrôlant chaque câble d’allumage de cette façon, il est possible de trouver les cylindres manquants.
Avertissement
Ne pas mettre la pointe d’essai du capteur directement en contact avec le circuit d’allumage secondaire.
Reconnaissance des pics
L’utilisateur peut présélectionner la valeur de seuil des pics et raccorder ensuite l’appareil
à un circuit. Lorsque la tension est plus haute que la valeur de seuil, un signal d’alarme retentit. Régler la valeur de seuil des pics par paliers de tension de 0,5 à 1,0, à 2,0, à 5,0, à
10,0, à 48,0 et vice-versa jusqu’à 0,5.
Avertissement : Ne pas mettre la pointe d’essai du capteur directement en contact avec le circuit d’allumage secondaire.
www.herthundbuss.com 16
17
Notizen
www.herthundbuss.com 18
Notizen
19
Herth+Buss
Herth+Buss
Dieselstraße 2-4 www.herthundbuss.com

Public link updated
The public link to your chat has been updated.
Advertisement
Key features
- Polarity and circuit circumstance testing
- Activating components with + or - current
- Voltage and continuity testing
- Illumination
- Locate missing cylinders
- Measuring frequency of ignition pulses
- Peak detection
- Voltage testing with 1/10 of a volt accuracy
- Short-circuit protection
- Extension cable and cigarette lighter plug included