The Uher 4000 Report IC is a high-quality tape recorder with a wide range of features, including multiple speeds, frequency response, and signal-to-noise ratio. It is designed for professional or demanding audio use, providing reliable performance for recording, playback, and editing. The unit is equipped with a comprehensive set of controls for adjusting recording levels, speed, and other settings, providing excellent flexibility for different recording situations.
Advertisement
Advertisement
Die Kennziffer der jeweiligen Leiterplatte und die Aufteilung dieser Leiterplatte in Plan- The reference number of the respective circuit board and the division of this printed cirquadrate (Rastergröße 10 mm x 10 mm) dient der Auffindung einzelner Bauteile. cuit into grid squares (grid size 10 mm x 10 mm) serves for locating individual components.
Beispiel: Die Diode D 301 befindet sich auf der Leiterplatte für die Motorsteuerelektronik Example: The diode D 301 is mounted on the circuit board for the motor control electronic im Planquadrat A 2. and the exact position is the grid square A 2.
363-44175/DEF/III/007/577-R
Wiedergabe-Entzerrung / Playback Equalization
Aufnahme-Entzerrung / Recording Equalization
Alle Spannungen In Stellung
Aufnahme mit Voltmeter (RI S
10 MOhm gegen + Pol der Batterie gemessen. Das Gehäuse
Ist vom + Pol der Batterie Isoliert. Alle Schalter in
Ruhestellung (bzw. Wiedergabe) gezeichnet.
All voltages are measured in recording position with voltmeter (impedance 10 megohms) to positive terminal of the battery. The chassis is insulated from the positive battery terminal. All switches shown In rest position, or In playback position resp.
Stromlaufplan
4000 REPORT IC
Circuit Diagram
Gültig ab Gerät Nr.: 142413001
Änderungen vorbehalten!
Valid from ser. no.: 142413001
Alterations reserved!
Servicehinweise
1. Öffnen des Gerätes
Zur Durchführung von Einstell- und Wartungsarbeiten ist der Geräteboden (durch Lösen der Verschlußschrauben) und die Isolierplatte (durch Abziehen) zu entfernen. Gegebenenfalls Leiterplatte
(Aufnahme-Wiedergabe-Verstärker 1-199) nach
Lösen der Befestigungsschraube herausschwenken.
2. Überprüfung der NF-Elektronik
Die Überprüfung der NF-Elektronik kann anhand des Blockschaltbildes erfolgen. Die im Gerät gemessenen Spannungen müssen mit den im Blockschaltbild angegebenen Werten übereinstimmen.
3.5 R312 Geschwindigkeitseinstellung: Zur Einstellung dient ein UHER-Geschwindigkeitsmeßband.
Die Messung wird bei der Bandgeschwindigkeit
19,05 cm/s durchgeführt. Mit dem Regler R312 die Abweichung auf ± 0 % einstellen (siehe die dem Meßband beiliegende Beschreibung).
3.6 R405 Batteriekontrolle: Knopf des Aussteuerungsreglers herausziehen und festhalten. Mit dem Regler R 405 wird bei einer Betriebsspannung von 5 V der Zeiger des Anzeigeinstrumentes auf den Wert 0 dB eingestellt.
3.7 R122 Gegenkopplung der ersten Verstärkerstufe: Zur Messung Tongenerator an die Kontakte 1 und 2 der Buchse "Radio/Phono" anschlie-
ßen und mit Vollaussteuerung 1000 Hz eine Aufnahme machen (zur Aufnahme UHER Testband verwenden). Bei der anschließenden Wiedergabe ein NF-Voltmeter an die Kontakte 3 und
2 der Buchse "Radio/Phono" anschließen. Die vom NF-Voltmeter angezeigte Spannung muß im
Bereich von 0,5 V bis 2 V liegen.
Sollte der Spannungswert nicht innerhalb dieses
Bereiches liegen, muß der Widerstand R122 zwischen 220 Ohm und 390 Ohm geändert werden. Eine Veränderung des Widerstandswertes ist erfahrungsgemäß nur nach Austausch des
Tonkopfes notwendig.
3. Reglereinsteilungen (siehe Abb. 1):
Voraussetzung für die Einstellung aller Regler ist, daß die Messungen bei einer einstellbaren, stabilen Betriebsspannung von 6 V vorgenommen werden.
3.1 R103 HF-Vormagnetisierung: Die HF-Vormagnetisierung beeinflußt den Frequenzgang des Gerätes. Die unten angegebene Spannung ist ein
Mittelwert; die endgültige Einstellung erfolgt nach der Kontrolle des Frequenzganges. NF-
Voltmeter im Punkt (A) gemäß Abb. 2 über den
Spannungsteiler anschließen. Mit R103 wird nunmehr am Voltmeter eine Spannung von
250 mV eingestellt.
Wird dieser Wert nicht erreicht, so ist zunächst der Abgleich des HF-Sperrkreises zu überprüfen. Aussteuerungsregler auf 0 stellen! NF-Voltmeter an Kontakt 2 der Buchse »Zusatzgeräte" und an Kontakt 2 (2 = Masse) der Buchse
„Radio/Phono" anschließen und durch Verschieben des Ferrit-Kernes der Spule L101 Hochfrequenzspannung auf Minimum einstellen.
3.2 R148 Aussteuerungsanzeige: Ober die Kontakte
1 und 2 (2 = Masse) der Buchse "Radio/Phono" wird vom Tongenerator eine Spannung von ca.
50 mV bei 1000 Hz eingespeist. An Kontakt 2 der Buchse "Zusatzgeräte" und an Kontakt 2
(2 = Masse) der Buchse "Radio/Phono" wird ein NF-Voltmeter angeschlossen. Die Tasten
Aufnahme, Pause und Start drücken. Aussteuerungsregler so einstellen, daß das Voltmeter eine Niederfrequenzspannung von 1,3 V anzeigt. R 148 ist so abzugleichen, daß der Zeiger des Aussteuerungsinstrumentes den Wert 0 dB anzeigt.
3.3 R 138 Aussteuerungsautomatik: Meßanordnung wie unter R148 Aussteuerungsanzeige Schalter
ALC in Stellung 1 (Sprache). An der Buchse
"Mikro" Punkt 3 und 2 (Masse) 1000 Hz. 0,5 mV einspeisen. Die vom NF-Millivoltmete'r angezeigte Ausgangsspannung muß 1,3 V ± 1 dB betragen. Anschließend die Eingangsspannung auf
16 mV erhöhen (+30 dB). Mit dem Regler R138 wird nun eine Ausgangsspannung eingestellt, die bei 1,3 V ( + 1 —1,5 dB) liegt.
3.4 Regelzeiten:
3.4.1. Sprache: Zur Kontrolle der Hochregelzeit werden an der Buchse "Mikro" 1000 Hz/5 mV eingespeist. Nach Verringern der Eingangsspannung auf 0,5 mV (— 20 dB) muß sich in einer
Zeit von 12 sec. ± 6 sec. die Ausgangsspannung von 1,3 V ± 1 dB eingestellt haben.
3.4.2. Musik: Schalter ALC in Stellung 2 Musik umschalten. An der Buchse "Radio/Phono" Punkt 1 und 2 (Masse) 1000 Hz/50 mV einspeisen. Nach
Verringern der Eingangsspannung auf 5 mV
(—20 dB) muß sich in einer Zeit von 75 sec. ±
35 sec. die Ausgangsspannung von 1,3 V ± 1 dB eingestellt haben.
4. Überprüfung der Endstufe
Tongenerator am Lautstärkeregler R 5 anschlie-
ßen und 1000 Hz/ca. 50 mV einspeisen. Lautsprecher abschalten und Lautsprecherausgang mit einem Widerstand 4 Ohm/1 W abschließen.
Parallel dazu NF-Voltmeter und Oszillograph anschließen.
Gerät auf Start schalten, Lautstärkeregler soweit aufdrehen, bis die vom Oszillographen angezeigte Sinuskurve ankappt (siehe Abb. 3). Am
NF-Voltmeter muß jetzt eine Spannung von mindestens 1,6 V (= 0,65 W) angezeigt werden.
NF-Voltmeter Ri > 10 MOhm.
5. Mechanische Prüfung
Vor jeder Prüfung sind sowohl die Gummiriemen als auch die Laufflächen aller rotierenden und durch Friktion getriebenen Teile des Laufwerkes mit Alkohol zu reinigen.
Die Messungen werden bei der Bandgeschwindigkeit 19,05 cm/s durchgeführt.
5.1 Kupplungen: a) Gerät auf Stop schalten. Gemäß Abb. 4 den
Abwickelzug prüfen.
Sollwert: 40 p ± 5 p bzw. 0,4 N ± 0,05 N.
b) Gerät auf Start schalten. Gemäß Abb. 4 Aufwickelzug messen. Federwaage darf nicht abgezogen werden.
Sollwert: 32 p ± 12 p bzw. 0,32 N ± 0,12 N.
5.2 Andruckrolle
Gerät auf Start schalten. Andruck gemäß Abb. 5 messen.
Sollwert: 415 p ± 35 p bzw. 4,15 N ± 0,35 N.
5.3 Schwungmasse (siehe Abb. 6):
Zur Messung der Andruckkraft Federwaage am
Punkt a einhängen. Taste Start drücken und
Federwaage in entgegengesetzter Richtung zum
Andruck der Schwungmasse (A) an das Antriebsrad (B) abziehen, bis das Antriebsrad (B) von der Schwungmasse (A) nicht mehr angetrieben wird.
Sollwert: 80 p ± 5 p bzw. 0,8 N ± 0,05 N.
Wird eine Einstellung der genannten Sollwerte erforderlich, siehe Serviceanleitung.
6. Technische Daten:
Alle technischen Daten werden entsprechend den durch die deutschen Normen (DIN) festgelegten Meßvorschriften für Magnettongeräte angegeben. Als Bezugsband dient BASF-DP26
Charge C264Z.
Spurlage
(International): Zweispur
Bandgeschwindig- 2,4 cm/s, 4,75 cm/s, keiten (International): 9,5 cm/s, 19 cm/s
Frequenzumfang:
Geräuschspannungsabstand:
Tonhöhenschwankung:
Löschdämpfung
19 cm/s 1000 Hz:
Eingänge:
Ausgänge:
Stromaufnahme:
Stromversorgung:
35— 5000 Hz (2,4 cm/s)
35— 8000 Hz (4,75 cm/s)
35— 16 000 Hz (9,5 cm/s)
35—20 000 Hz (19 cm/s)
>56 dB (19 cm/s)
±0,2 %(19 cm/s)
± 0,25 % ( 9,5 cm/s)
± 0,35 % ( 4,75 cm/s) .
± 0,5 % ( 2,4 cm/s)
>70 dB
Mikrofon:
0,12 mV—ca. 40 mV an 200 Ohm
Radio:
2,4 mV — ca. 700 mV an 47 kOhm
Phono:
45 mV—ca. 20 V an MOhm
1,6 V/4 Ohm;
500 mV -2 V/15 kOhm max. 440 mA
(in Stellung"Start" bei
19 cm/s, Band eingelegt,
Lautstärkeregler zu)
5 Monozellen 1,5 V oder
"dryfit PC"-Akkumulator
Z 212 oder Nickel-
Cadmium-Akkumulator
Z 214 oder Netzgerät
Z 124 A1 oder Autoanschlußkabel Typ K717 für 12 V.
Service Instructions
1. Opening the machine
In order to carry out adjusting and maintenance work, loosen locking screws and remove bottom lid of the machine's housing, then pull-off insulating plate. If necessary loosen fixing screws and turn out printed circuit board (record/playback amplifier
1-199).
2. Checking the Low Frequency Electronic
Checking of the LF electronic may be effected based on the block schematic diagram. The tension measured in the unit have to be in accordance with the data indicated in the block schematic diagram.
3. Adjustment of variable resistors
(see Fig. 1):
A prerequisite for any alignment is that measurements be made while the recorder is fed with an adjustable and constant supply voltage of
6 volts.
3.1 R103, RF-Bias: The RF-Bias Influences the frequency response of the recorder. The voltage mentioned below is a mean value; the final adjustment should only be made after the frequency response has been checked. Connect an audio-frequency VTVM via a voltage divider to point A in accordance with Fig. 2. Adjust for a
VTVM reading of 250 millivolts by means of the variable resistor R 103.
If this value cannot be attained, first check the alignment of the RF block circuit. Set the recording level control at zero. Connect an audiofrequency VTVM across the contact 2 of the
"Accessories" socket and contact 2 (2 = chassis) of the "Radio/Phono" socket and adjust for a minimum reading by sliding the ferrite core of the coil L101.
3.2 R 148, Recording level indication: Connect an audio oscillator across the contacts 1 and 2 (2
= chassis), of the "Radio/Phono" socket and feed a signal of 1,000 Hz at approximately
50 millivolts. Connect an audio-frequency VTVM across the contact 2 of the "Accessories" socket and contact 2 (2 = chassis) of the "Radio/
Phono" socket. Depress the recording, pause and start key Adjust, by means of the recording level control, a VTVM reading of 1.3 volts.
Now adjust the recording level meter to read zero dB, by means of the variable resistor R 148.
3.3 R 138, Automatic level control: Measuring setup as under R148 level control indicating switch
ALC in position 1 (speech). Feed in 1000 Hz
0.5 mV at socket "Mikro" points 3 and 2(chassisground). The output voltage indicated by the LF millivoltmeter must be 1.3 V ± 1 dB. Subsequently increase the input voltage to 16 mV (+30 dB).
Now adjust an output voltage with control R 138 which must be 1.3 V ( + 1 —1.5 dB).
3.4 Control times:
3.4.1. Speech: for checking the upward control time, feed in 1000 Hz/5 mV at socket "Mikro". After reducing the input voltage to 0.5 mV (—20 dB), the output voltage of 1 . 3 V ± 1 dB must have appeared after a period of 12 sec ± 6 sec.
3.4.2. Music: change over ALC switch to position
2 "Musik". Feed in 1000 Hz/50 mV at socket
"Radio/Phono" points 1 and 2 (chassis-ground).
After reducing the input voltage to 5 mV
(—20 dB), the output voltage of 1.3 V ± 1 dB must have appeared after a period of 75 sec
± 35 sec.
3.5 R 312, Speed adjustment: The speed is adjusted by using an UHER Speed Test Tape at the speed of 7 1/2 ips. Thread the tape and read the deviation. Adjust the deviation to ± zero % by means of the variable resistor R312 which is capable of counter-balancing deviations of up to approximately ± 8 Vo.
3.6 R 405, Adjustment of the recording level meter for battery life indication: Pull the knob of the recording level control and keep it in that position. Adjust the variable resistor R405 so that the meter reads zero dB at a supply voltage of
5 volts.
3.7 R 122, Negative feedback of the first amplifier stage: For the measurement connect audio-frequency signal generator to contacts 1 and 2 of socket "Radio/Phono" and make a recording at maximum level 1000 Hz (for the recording use
UHER test tape). With the subsequent playback connect an LF tube voltmeter to contacts 3 and
2 of socket "Radio/Phono". The voltage indicated by the LF voltmeter must be in the range of
0.5 - 2V.
Should the voltage value not be within this range, the resistor R122 must be varied between 220 Q and 390 Q. A change in the resistance value, as experience has shown, is only necessary after the replacement of a sound head.
4. Checking the final stage:
Connect audio-frequency signal generator to volume control R5 and feed in 1000 Hz/approx.
50 mV. Disconnect loudspeaker and terminate loudspeaker output into a resistor of 4 Ohm/1 W.
Connect an LF voltmeter and an oscilloscope in parallel with this circuit.
Turn recorder to Start, turn on the volume control up to a point where the sine curve displayed by the oscilloscope flattens out (see Fig. 3).
At the LF voltmeter, a voltage of not less than
1,6 V (= 0.65 W) must now be indicated.
AF voltmeter Ri > 10 MQ.
5. Mechanical measurement:
Whenever the recorder is checked, always clean with pure alcohol the rubber belts and the treads of all the rotating parts of the mechanism, that are driven by friction.
The measurements should be made at tape speed
19.05 cm/s.
5.1 Clutches: a) Operate position "Stop". Check the friction of the clutch according to Fig. 4.
Nominal value: 40 p ± 5 p or 0.4 N ± 0.05 N.
b) Operate position "Start" and measure the pull of the turntable as shown in Fig. 4.
Spring balance must not be removed.
Nominal value: 32 p ± 12 p or 0.32 N ± 0 . 1 2 N .
5.2 Pressure roller:
Operate position "Start". Measure the pressure as shown in Fig. 5.
Nominal value:
415 p ±35 p or 4.15 N±0.35 N.
5.3 Flywheel (see Fig. 6):
For measuring the force of the pressure, hook in the spring balance at point a. Press the Start push-button and tension the spring balance in the opposite direction for pressing the flywheel
(A) onto the drive wheel (B), until the drive wheel (B) is no longer driven by the flywheel (A).
Nominal value: 80 p ± 5 p or 0.8 N ± 0.05 N.
All adjustments, that should become necessary have to be made as described in the Service
Manual.
6. Technical Specifications:
All specifications are given on the basis of the pertaining German DIN standards. For measurements use BASF-DP 26 Test tape batch no.
C 264 Z only.
Recording Sense
(international standart):
Tape Speeds (international standart): two tracks
15/16 ips, 1 7/8 ips,
3 3/4 ips, 7 1/2 ips
Frequency response:
35— 5,000 Hz at 15/16 ips
35— 8,000 Hz at 1 7/8 ips
35—16,000 Hz at 3 3/4 ips
35—20,000 Hz at 7 1/2 ips
Signal-to-noise ratio, weighted: > 56 dB (7 1/2 ips)
Wow and Flutter:
±0.2 %(19 cm/s)
± 0.25 %( 9.5 cm/s)
± 0.35 % ( 4.75 cm/s)
± 0.5 % ( 2.4 cm/s)
Erasure
7 1/2 ips 1000 Hz:
>70 dB
Inputs:
Micro:
0.12 mV— approx. 40 mV across 200 Ohm
Radio:
2.4 mV— approx. 700 mV across 47 kOhm
Phono:
45 mV — approx. 20 V across 1 MOhm
Outputs:
Consumption:
Power Supplies:
1.6 V/4 Ohm;
500 mV - 2 V/15 kOhm
440 mA max. in "start" position at 7 1/2 ips tape inserted, volume control at zero
5 flashlight cells (1.5 volts each) or "dryfit PC" storage battery Z 212 or nickel-cadmiùm storage battery Z 214 or Model
Z 124 A1 mainsoperated power unit or an automobile adaptor cable
(Model K 717 for 12 volts)
Instructions de Service
1. Ouverture du magnétophone
Pour l'exécution des travaux de réglage et d'entretien, ouvrir la base du coffret, après le desserage des vis de fixation et retirer la plaque isolante. Si nécessaire tourner dehors la plaque de circuit imprimé (amplificateur enregistrement/lecture
1-199).
2. Contrôle de l'électronique de basse fréquence
Pour le contrôle de l'électronique de BF vous pouvez vous référer au bloc-diagramme. Les tensions mesurées dans la machine doivent correspondre aux valeurs indiquées au bloc-diagramme.
3. Réglage des potentiomètres (voir fig. 1):
Le réglage des potentiomètres s'opère en présence d'une tension de fonctionnement stable de 6 V.
3.1 R 103 — Prémagnétisation HF: La prémagnétisation HF se repercute sur la courbe de réponse enregistrement-lecture du magnétophone et sur la distorsion harmonique de l'enregistrement. La tension indiquée ci-dessous représente une valeur moyenne. Le réglage définitif s'exécute après le contrôle de la courbe de réponse et de la distorsion harmonique.
A travers un diviseur de tension, brancher un voltmètre BF au point de connexion 116 (voir fig. 2. Ajuster le potentiomètre R103 de façon que le voltmètre indique une tension de 250 mV.
Si cette valeur ne peut pas être obtenue, vérifier l'équilibrage du filtre de coupure HF. Ajuster le modulomètre sur «0» à l'aide du régleur
«REC. LEV». Brancher le voltmètre BF sur le contact 2 de la prise «Accessories» et sur le contact 2 (masse) de la prise «Radio/Phono».
Agir sur le noyau de ferrite de la bobine L 101 pour donner à la tension HF sa valeur minimale.
3.2 R 148 — Ajustage du modulomètre: Brancher un générateur BF sur les contacts 1 et 2 de la prise
«Radio/Phono». Appliquer un signal de 1000 Hz
à environ 50 mV.
Raccorder un voltmètre BF sur le contact 2 de la prise «Accessoires» et sur le contact 2
(masse) de la prise «Radio/Phono». Enfoncer les touches «Enregistrement», «Pause» et «Start».
Faire tourner le régleur de niveau «REC. LEV.» vers la droite, jusqu'à ce que le voltmètre indique une tension de 1,3 V.
Ajuster ensuite le potentiomètre R 148, de façon que l'aiguille du modulomètre s'immobilise sur
«0dB».
3.3 R138 — Ajustage du système de réglage automatique du niveau d'enregistrement: Opérer comme décrit ci-dessus pour le potentiomètre
R 148. Raccorder un générateur sur les contacts
3 et 2 (masse) de la prise «Micro». Appliquer un signal de 1000 Hz à 0,5 mV. Mettre le sélecteur ALC en position 1 («Parole»).
Le millivoltmètre BF doS indiquer une tension de sortie de 1,3 V ± 1 dB. Augmenter la tension d'entrée sur une valeur de 16mV. Avec le potentiomètre R138, ajuster la tension de sortie sur 1,3 V ( + 1 —1,5 dB).
3.4 Contrôle du temps de correction:
3.4.1. «Parole»: Le sélecteur ALC se trouve dans sa position 1 («Parole»). Avec le générateur BF branché sur les contacts 3 et 2 de la prise
«Micro», appliquer un signal de 1000 Hz à 5 mV.
Abaisser sur 0,5 mV (— 20 dB) le niveau de sortie du générateur BF. Après 12 sec. ± 6 sec, la tension de sortie indiquée par le millivoltmètre doit reprendre sa valeur de 1,3 V± 1 dB.
3.4.2. «Musique»: Mettre le sélecteur ALC dans sa position 2 («Musique»). Avec le générateur BF branché sur les contacts 1 et 2 (masse) de la prise «Radio/Phono», appliquer un signal de
1000 Hz à 50 mV. Abaisser sur 5 mV (—20 dB) le niveau de sortie du générateur BF. Après
75 sec. ± 35 sec, la tension de sortie indiquée par le millivoltmètre doit reprendre sa valeur de
1 , 3 V ± 1 d B .
3.5 R 312 — Ajustage de la vitesse de défilement:
L'ajustage s'effectue avec une bande de mesure de défilement UHER et à une vitesse de 19,05 cm/s. Agir sur le potentiomètre R312 pour amener à ± 0 % l'erreur de la vitesse de défilement (consulter les instructions jointes à la bande de mesure UHER).
3.6 R 405 — Contrôle de la batterie: Tirer en avant le bouton du régleur «REC. LEV.» et le maintenir dans cette position. A une tension de fonctionnement de 5 V, agir sur le potentiomètre
R 405 jusqu'à ce que l'aiguille du modulomètre s'immobilise en face de «0 dB».
3.7 R122 — Contre-réaction du premier étage amplificateur: Brancher un générateur BF sur les contacts 1 et 2 de la prise «Radio/Phono» et exécuter un enregistrement en pleine charge
(niveau maximal d'enregistrement) du signal de
1000 Hz. Utiliser à cet effet une bande de test
UHER.
Raccorder ensuite un voltmètre à lampe BF sur les contacts 3 et 2 de la prise «Radio/Phono» et enclencher le magnétophone en régime «Reproduction». La tension indiquée par le voltmètre doit être située entre 0,5 V et 2 V.
Si la valeur de la tension est incorrecte, modifier l'ajustage du potentiomètre R122 (entre
220 ohms et 390 ohms). Un tel réajustage n'est en général nécessaire qu'après l'échange de la tête magnétique.
4. Contrôle de l'étage final:
Brancher un générateur BF sur le régleur R 5 du volume acoustique et injecter un signal de
1000 Hz à 50 mV. Déconnecter le haut-parleur et terminer la sortie de ce dernier avec une résistance de 4 ohms/1 W. Raccorder en parallèle
à cette sortie un voltmètre BF et un oscillographe.
Enfoncer la touche «Start» et manœuvrer vers la droite le bouton du régleur «Volume», jusqu'à ce qu'une courbe sinusoïdale apparaisse sur l'écran de l'oscillographe (voir fig. 3). Le voltmètre BF doit alors indiquer une tension d'au moins 1,6 V (0,65 W).
Voltmètre BF Ri > 10 MOhm.
5. Contrôle mécanique:
Avant chaque mise en opération du magnétophone passer un chiffon imbibé d'alcool sur les courroies de caoutchouc, ainsi que sur les surfaces de roulement de tous les organes tournants et entraînés par friction. ;
Les mesures s'exécutent en présence d'une vitesse de défilement de 19,05 cm/s.
5.1 Embrayages: a) Mettre le magnétophone dans sa position
«Stop». Conformément à la fig. 4, mesurer la traction de déroulement.
Valeur nominale:
40 p ± 5 p resp. 0,4 N ± 0,05 N.
b) Mettre le magnétophone dans sa position
«Start». Conformément à la fig. 4, mesurer la traction d'enroulement. Le pèse-ressort ne doit pas être étirél
Valeur nominale:
32 p ± 12 p resp. 0,32 N ± 0,12 N.
5.2 Galet de pression:
Mettre le magnétophone dans sa position
«Start». Mesurer l'effort selon fig. 5.
Valeur nominale:
415 p ± 35 p resp. 4,15 ± 0,35 N.
5.3 Volant voir fig. 6):
Pour la mesure de cet effort, accrocher un pèseressort au point a et enfoncer la touche «Start».
Etirer le pèse-ressort pour supprimer la friction entre le volant (A) et la roue d'entraînement (B).
Valeur nominale:
80 p ± 5 p resp. 0,8 N ± 0,05 N.
Si une adaptation des valeurs nominales devient nécessaire voir instructions de service.
6. Caractéristiques techniques:
Toutes les caractéristiques techniques ont été déterminées au moyen d'une bande de référence
à faible bruit de fond (BASF-DP26 Charge
C 264 Z) et d'après les méthodes prescrites pour les magnétophones par les normes allemandes DIN.
Enregistrement
(international):
Vitesse de défilement
(international):
Gamme de fréquences:
à deux pistes
2,4 cm/s, 4,75 cm/s,
9,5 cm/s, 19 cm/s
35— 5000 Hz (2,4 cm/s)
35— 8000 Hz (4,75 cm/s)
35— 16000 Hz (9,5 cm/s)
35—20 000 Hz (19 cm/s)
Dynamique:
Pleurage:
Dynamique
d'effacement en 19 cm/s 1000 Hz:
Entrées:
Sortie:
Puissance consommée:
Alimentation en courant:
> 56 dB (19 cm/s)
±0,2 %(19 cm/s)
± 0,25 % ( 9,5 cm/s)
± 0,35 % ( 4,75 cm/s)
± 0,5 % ( 2,4 cm/s)
Abb. 3
Fig. 3
Gezeichnet in Stellung Aufnahme bzw. Ruhestellung
Drawing refers to position rec and pause respectively
Dessiner à la position enregistrement et pause respectivement
Abb. 1