CLIMAVENETA TELECOMSOLUTIONS Units for mobile telecommunication applications, with free cooling and full DC Inverter technology. 1,5 ÷ 20 kW. Low operational and maintenance costs Wide range of full inverter solutions Reliability and extended operation Advanced control CLIMAVENETA TELECOM SOLUTIONS Reliability and extended operation Reliability and extended operation Constructional rationality plus the proven high quality of the components ensure that Climaveneta’s units offer: a Continuous operation (24 hours a day, 365 days a year) a Design life of over 10 years a MTBF and MTTR values at the top of their category. Unmanned premises with almost no latent heat value. Required S.H.R. ≥95% High capacity sensitive cooling Manned premises with latent heat value. Required S.H.R. ≥60% No latent cooling required. Since the technological rooms are unmanned, the latent heat values remain almost zero. 95% Thus, the requested S.H.R. values (Sensible and Total Cooling Capacity Ratio) are 95%, compared to typical S.H.R values of around 60% in the manned premises. 60% Black-out management Internal Machinery Temperature °C System On UPS connections system (24/48V DC) Black-Out - Power Loss 70 Without Free Cooling For the double power supply versions (UPS, 48V DC), the Free cooling function is instantly activated in the event of a blackout. 60 50 With Free Cooling 40 30 20 0 15' 30' 45' Time 2 l 3 TELECOMSOLUTIONS 1h 15' 30' 45' 2h Advanced control Microprocessor control Stand-by and alarm management The microprocessor allows: a a a a a a a a a a a easy-to-use navigation advanced management of the stand-by unit automatic rotation on a time basis alarm rotation alarm management and transmission LAN management between connected units easy connection to supervisory systems double power supply management multi-language management emergency function manual function Extremely low noise 60 Minimum sound emissions <Measurement of outside with evaporating fan only in free cooling. <Measurement of outside during recirculation. 40 decibel dB Reducing sound emissions is one of the greatest needs of air conditioning units located in urban areas. 50 30 20 Climaveneta has therefore made a new range of high efficiency air conditioners featuring a strong sound emission reduction: 10 0 -50 4 Sound proofing delivery plenum 80 4 Compressor inside a sound proofing box with lead 70 4 Sound proofing recirculating fans cap 60 4 Condensing pressure check through the fan speed regulator 4 Autotransformer to reduce vibration decibel dB 4 Anti-vibration feet for the unit and the fans fastening Hz 100 200 500 1K frequency 2K 5K 10K 20K(L) (A) <Others/Competitors <Climaveneta 50 40 30 25 6 kW 9 kW HED + HCAT 15 kW 6 kW 9 kW MED 15 kW 6 kW 9 kW MID 15 kW CLIMAVENETA TELECOM SOLUTIONS Climaveneta for telecommunication applications Mobile phone base stations, shelters and switch cabinets: all these critical applications need technologically advanced solutions tailored to the customer’s needs. 4 l 5 TELECOMSOLUTIONS Climaveneta has developed Telecom Solutions, a complete range of air conditioners from 1,5 to 20kW, divided into split and packaged versions, for outdoor or indoor installation. The renovated range combines more than 40-years of experience in the air conditioning sector with high standards of quality and reliability resulting from the continuous improvement of manufacturing operations. a End-of-line testing on all units a Customised solutions according to specific customer requirements a Accreditation service for direct orders An extensive sales network and a number of after sales services ranging from technician training to the informative multimedia material add further value to the new Telecom Solutions offerings. a Certification of the unit’s technical features in the test chambers HED HCAT/i-HED i-HCAT FKO/FKI FREE COOLER 0011÷0071 0021÷0051 pg. 8 pg. 14 Split air conditioners. Cooling capacity from 4,9 to 17 kW FREE COOLING Free cooling unit for telecommunication shelters from 7,7 to 10,1kW. Indoor or outdoor installation. FREE COOLING MID/i-MID LED 0001÷0061 pg. 10 Indoor packaged air conditioners. Cooling capacity from 1,5 to 15 kW FREE COOLING MED/i-MED 0001÷0091 pg. 12 Outdoor packaged air conditioners. Cooling capacity from 1,95 to 20 kW FREE COOLING 0010E÷0015E pg. 16 Outdoor packaged air conditioners. Cooling capacity from 2,5 to 5,7 kW FREE COOLING CLIMAVENETA TELECOM SOLUTIONS Climaveneta Telecom Solutions is the result of a research and development project among different telecommunications companies aimed at finding an innovative no-compromise solution for the modern telecommunication applications. Low operational and maintenance costs Free cooling mode Sound emissions reduction 24/7 continuous operation (24 hours a day, 365 days a year) Highly sensitive cooling Precision control and total reliability UPS Advanced management of stand-by unit alarms through the microprocessor control 10 YEARS Expected lifetime over 10 years 6 l 7 TELECOMSOLUTIONS Back-up and UPS systems (48 VDC) Inverter technology The inverter driven compressor is a key component for Climaveneta’s products: thanks to its extremely precise regulation of the power capacity through variable frequency, it can strongly increase the efficiency of partial loads. Compared to a traditional on/off compressor, the inverter technology ensures a quick achievement of the desired set point and a precise control over temperature variations. Once the desired value has been reached, the compressor rotation decreases, reducing energy consumption and effectively maintaining the temperature conditions over time. In this respect the new Climaveneta’s Telecom Solutions range represents the ultimate solution in air conditioning in the telecommunications sector, thanks to the most updated DC Inverter Brushless compressors and the new generation EC fans combined with the electronic thermostatic valve. Both solutions allow for perfect adaptation of the unit’s performance to the real requirements of the building even at partial load, which represents more than 75% of the operating time of the system. This ensures an energy savings of up to 50% more than solutions based on traditional ON/OFF compressors. Annual Energy Consumption Low operational and maintenance costs 100% In case of low Hz Operation Key features of efficient and long-lasting air conditioning systems are reduced energy consumption combined with low operational and maintenance costs. Max 70% 55% For this reason the modern FULL INVERTER units deliver the best cost and benefit ratios, with significant advantages in terms of TCO (Total Cost of Ownership). Consequently, the payback time is 2 years compared to NON FULL INVERTER solutions where payback per unit only comes after 10 years. 30% Constant speed AC Inverter DC Inverter DOUBLE ADVANTAGE: FREE COOLING + INVERTER It is well known that energy savings are guaranteed with FREE COOLING systems. Climaveneta combines innovative FULL INVERTER compressors with the free cooling technology, thus resulting in 35% higher energy savings compared to traditional on/off solutions. TELECOM SOLUTIONS HED-HCAT / i-HED - i-HCAT 0011÷0071 Split air conditioners for telecommunication shelters Free Cooling Unit description Features HED-HCAT split air conditioners for telecommunication shelters combine a HCAT condenser (available in both the BASIC and LT low temperature versions) with the indoor HED unit. a Structure and panelling in electrogalvanised powder coated steel for maximum resistance to rust. a Total reliability and functionality of the compressor and all other components guaranteed by leading companies in the telecoms sector. a Contacts for alarms and the machine's functioning state signals. a Universal terminal board for complete outer control of the PLC unit. a Condensing control for lower noise levels. a Safety pressure switches. a Condensing coil protection grills. a User terminal supplied as standard. a Wide range of accessories for easy and correct installation, and for an efficient air treatment system. a Widespread after sales network Available for ceiling or wall installation, HED-HCAT units are available with product ranges from 4,9 to 17kW, both in the ON-OFF and Inverter technology. All the units are equipped with external panels in electrogalvanised powder coated steel sheets and, upon request, with a Free Cooling damper which ensures 30% annual energy savings compared to standard systems. The evaporating section fan works on a direct current at 48 Volts for a reliable operation even in emergency situations (optional). Climaveneta units are made to ensure a standard level of operation even under extreme environmental conditions with temperatures of up to +48°C. Main options a a a a Electric heating elements. Serial cards for BMS interconnection. 48V DC power supply for emergency situations. Free Cooling damper with opening from 0 to 100%. Split Free Cooling 8 l 9 TELECOMSOLUTIONS Mechanical ON/OFF Version 0011 0021 0021 0031 0031 0041 0051 0056 0061 1/1 R410A 230/1/50 1/1 R410A 230/1/50 1/1 R410A 400/3N/50 1/1 R410A 230/1/50 1/1 R410A 400/3N/50 1/1 R410A 400/3N/50 1/1 R410A 400/3N/50 1/1 R410A 400/3N/50 1/1 R410A 400/3N/50 dB(A) 4,94 4,94 1,00 1,18 1450 1450 0,29 0,20 2500 0,13 1,70 48 -20 -35 52 6,36 5,65 0,89 1,62 1450 1450 0,29 0,20 2500 0,13 1,70 48 -20 -35 53 6,36 5,65 0,89 1,62 1450 1450 0,29 0,20 2500 0,13 1,70 48 -20 -35 53 8,43 6,77 0,80 2,27 1600 1600 0,31 0,21 2500 0,13 1,70 48 -20 -35 56 8,41 6,75 0,80 2,26 1600 1600 0,31 0,21 2500 0,13 1,70 48 -20 -35 56 9,71 9,17 0,94 2,37 2450 2450 0,45 0,49 3600 0,13 3,40 48 -20 -35 56 10,6 9,53 0,90 2,72 2450 2450 0,45 0,49 3600 0,13 3,40 48 -20 -35 56 14,3 12,5 0,87 3,64 3200 3200 0,49 0,52 4900 0,25 3,40 48 -20 -35 58 15,8 13,8 0,87 4,10 3200 3200 0,49 0,52 4900 0,25 3,40 48 -20 -35 58 mm mm mm mm mm mm mm mm mm kg kg kg 1500 1060 900 990 990 370 310 310 740 85 74 67 1500 1060 900 990 990 370 310 310 740 85 74 93 1500 1060 900 990 990 370 310 310 740 85 74 93 1500 1060 900 990 990 370 310 310 740 85 74 87 1500 1060 900 990 990 370 310 310 740 85 74 93 1523 1236 900 1110 1110 370 400 405 990 123 107 109 1523 1236 900 1110 1110 370 400 405 990 121 98 102 1523 1236 900 1110 1110 420 400 405 1240 128 109 125 1523 1236 900 1110 1110 420 400 405 1240 130 111 130 HED HCAT N° Circuits / N°Compressors Refrigerant Power supply COOLING CAPACITY Total cooling capacity Sensible cooling capacity SHR Compressors power input Evaporator air flow Free-cooling air flow (opt.) Evaporator fan 48 V DC power input (opt.) Evaporator fan AC power input Condenser air flow Condenser fan AC power input Electric heater capacity (opt.) Max. outdoor temperature (BASIC/LT) Min. outdoor temperature (BASIC) Min. outdoor temperature (LT) Outdoor sound pressure level V/Ph/Hz (1) (1) (1) (1) °C °C °C (2) kW kW kW m3/h m3/h kW kW m3/h kW kW Dimensions and Weight Width HED Depth HCAT HED Height HCAT HED Net weight HCAT HED With Free cooling Without Free cooling With Free cooling Without Free cooling With Free cooling Without Free cooling With Free cooling Without Free cooling HCAT Inverter Version i-HED i-HCAT N° Circuits / N°Compressors Refrigerant Power supply COOLING CAPACITY Total cooling capacity Sensible cooling capacity SHR Compressors power input Evaporator air flow Free-cooling air flow (opt.) Evaporator fan 48 V DC power input (opt.) Evaporator fan AC power input Condenser air flow Condenser fan AC power input Electric heater capacity (opt.) Max. outdoor temperature (BASIC/LT) Min. outdoor temperature (BASIC) Min. outdoor temperature (LT) Outdoor sound pressure level V/Ph/Hz (1) (1) (1) (1) (2) kW kW kW m3/h m3/h kW kW m3/h kW kW °C °C °C dB(A) 0031 0051 0071 1/1 R410A 230/1/50 1/1 R410A 230/1/50 1/1 R410A 400/3N/50 MAX 9,73 7,29 0,75 2,38 1600 1600 0,31 0,21 3200 0,13 MIN 4,34 4,34 1,00 0,75 800 800 0,09 0,16 3200 0,13 MAX 12,6 11,0 0,87 3,18 3200 3200 0,49 0,52 6400 0,25 MIN 4,84 4,84 1,00 0,78 1600 1600 0,15 0,39 6400 0,25 MAX 17,3 15,4 0,89 4,23 3900 3900 0,50 0,54 8640 0,53 MIN 6,97 6,97 1,00 1,10 1950 1950 0,15 0,41 8640 0,53 1,7 48 -20 -35 56 3,4 48 -20 -35 56 3,4 48 -20 -35 58 1500 1060 900 990 990 420 310 310 990 85 74 100 1523 1236 900 1100 1100 420 400 405 1240 120 109 108 1618 1236 1200 1340 1340 550 450 450 1200 155 125 175 Dimensions and Weight Width Depth Height Net weight i-HED With Free cooling Without Free cooling i-HCAT i-HED With Free cooling Without Free cooling i-HCAT i-HED With Free cooling Without Free cooling i-HCAT i-HED With Free cooling Without Free cooling i-HCAT mm mm mm mm mm mm mm mm mm kg kg kg Notes (1) Ref. Conditions: Indoor=27°C, 45%UR Outdoor=35°C (2) Measured at a height of 1 m and 1 m from the front of the unit in free field TELECOM SOLUTIONS MID / i-MID 0001÷0061 Packaged air conditioners for telecommunication shelters Free Cooling Unit description Features Available with cooling capacity from 1,9 to 15 kW. They are direct expansion packaged systems for indoor installation, which are fitted with external panels in powder coated steel sheets. a Structure and panelling in electrogalvanised powder coated steel for maximum resistance to rust. a Total reliability and functionality of the compressor and all other components guaranteed by leading companies in the telecoms sector. a Both horizontal (ceiling ) and vertical (wall) installations of HED/i-HED available (universal installation). a Contacts for alarms and the machine's functioning state signals. a Universal terminal board for complete outer control of the PLC unit. a Condensing control for lower noise levels. a Safety pressure switches. a Condensing coil protection grills. a User terminal supplied as standard. a Wide range of accessories for easy and correct installation, and for an efficient air treatment system. a Widespread after sales network The units can be fitted with a Free Cooling damper (optional) that ensures 30% annual energy savings compared to standard systems, while the evaporating section fan works on a direct current at 48 Volts for a reliable operation even in an emergency situation. (optional) Climaveneta units are made to ensure a standard level of operation even under extreme environmental conditions with temperatures of up to +48°C. MID/i-MID are available in two different versions: in the UNDER units, the outlet air flow is flush to the ground and pointed downwards , while in the OVER versions (for MID units only) the air flow inlet is from the front side and the air flow outlet is upwards or frontal. Indoor Free Cooling a a a a Electric heating elements. Serial cards for BMS interconnection. 48V DC power supply for emergency situations. Free Cooling damper with opening from 0 to 100%. Mechanical Over 10 l 11 TELECOMSOLUTIONS Main options Free Cooling Mechanical Under ON/OFF Version MID N° Circuits / N°Compressors Refrigerant Power supply COOLING CAPACITY Total cooling capacity Sensible cooling capacity SHR Compressors power input Evaporator air flow Free-cooling air flow (opt.) Evaporator fan 48 V DC power input (opt.) Evaporator fan AC power input Condenser air flow Condenser fan AC power input Electric heater capacity (opt.) Max. outdoor temperature (BASIC/LT) Min. outdoor temperature (BASIC) Min. outdoor temperature (LT) Outdoor sound pressure level 0001 0003 0004 0011 0021 0021 0031 1/1 R410A 230/1/50 1/1 R410A 230/1/50 1/1 R410A 230/1/50 1/1 R410A 230/1/50 1/1 R410A 230/1/50 1/1 R410A 400/3N/50 1/1 R410A 230/1/50 kW m3/h m3/h kW kW m3/h kW kW °C °C °C dB(A) 1,95 1,42 0,73 0,60 300 300 0,04 0,06 500 0,14 1,00 48 -20 n.a. 49 2,91 2,67 0,92 0,81 990 990 0,18 0,15 1210 0,23 1,00 48 -20 n.a. 52 3,45 2,88 0,83 0,98 990 990 0,18 0,15 1210 0,23 1,00 48 -20 n.a. 52 4,94 4,94 1,00 1,18 1450 1450 0,24 0,26 2600 0,73 1,70 48 -20 -35 53 6,09 5,49 0,90 1,69 1450 1450 0,24 0,26 2600 0,73 1,70 48 -20 -35 53 6,09 5,49 0,90 1,62 1450 1450 0,24 0,26 2600 0,73 1,70 48 -20 -35 53 8,14 6,72 0,83 2,33 1450 1450 0,25 0,26 2600 0,73 1,70 48 -20 -35 54 8,01 6,66 0,83 2,26 1450 1450 0,25 0,26 2600 0,73 1,70 48 -20 -35 54 9,52 8,64 0,91 2,35 2200 2200 0,45 0,48 3700 0,79 3,40 48 -20 -35 56 10,6 9,07 0,85 2,78 2200 2200 0,45 0,48 3700 0,79 3,40 48 -20 -35 56 13,8 12,5 0,90 3,51 3200 3200 0,49 0,52 4500 0,83 3,40 48 -20 -35 60 14,8 12,9 0,87 4,09 3200 3200 0,49 0,98 4500 0,83 3,40 48 -20 -35 61 mm mm mm mm mm mm kg kg 394 n.a. 250 n.a. 900 n.a. 43,5 n.a. n.a. 505 n.a. 395 n.a. 1265 n.a. 85 n.a. 505 n.a. 395 n.a. 1265 n.a. 85 650 650 650 650 2075 2000 163 180 650 650 650 650 2075 2000 176 193 650 650 650 650 2075 2000 176 193 650 650 650 650 2075 2000 172 189 650 650 650 650 2075 2000 185 202 895 895 750 750 2050 2050 262 252 895 895 750 750 2050 2050 270 260 895 895 750 750 2050 2050 275 265 895 895 750 750 2050 2050 290 280 V/Ph/Hz (1) (1) (1) (1) (2) kW kW 0031 0041 0051 0056 0061 1/1 1/1 1/1 1/1 1/1 R410A R410A R410A R410A R410A 400/3N/50 400/3N/50 400/3N/50 400/3N/50 400/3N/50 Dimensions and Weight Width Depth Height Net weight OVER UNDER OVER UNDER OVER UNDER OVER UNDER Inverter Version i-MID N° Circuits / N°Compressors Refrigerant Power supply COOLING CAPACITY Total cooling capacity Sensible cooling capacity SHR Compressors power input Evaporator air flow Free-cooling air flow (opt.) Evaporator fan 48 V DC power input (opt.) Evaporator fan AC power input Condenser air flow Condenser fan AC power input Electric heater capacity (opt.) Max. outdoor temperature (BASIC) Min. outdoor temperature (BASIC) Outdoor sound pressure level V/Ph/Hz (1) (1) (1) (1) (2) kW kW kW m3/h m3/h kW kW m3/h kW kW °C °C dB(A) 0031 0051 0061 1/1 R410A 230/1/50 1/1 R410A 230/1/50 1/1 R410A 400/3N/50 MAX 9,53 7,09 0,74 2,37 1600 1600 0,25 0,26 2600 0,73 MIN 4,34 4,34 1,00 0,75 800 800 0,08 0,20 2600 0,73 MAX 12,3 10,7 0,87 3,18 3200 3200 0,48 0,48 4500 0,75 MIN 4,84 4,84 1,00 0,78 1600 1600 0,14 0,14 4500 0,75 MAX 15,1 12,8 0,85 4,66 3200 3200 0,49 0,98 4500 0,83 MIN 6,58 6,16 0,94 1,10 1600 1600 0,15 0,29 4500 0,83 1,7 48 -20 54 3,4 48 -20 56 3,4 48 -20 61 n.a. 650 n.a. 650 n.a. 2000 n.a. 205 n.a. 895 n.a. 750 n.a. 2050 n.a. 246 n.a. 895 n.a. 750 n.a. 2050 n.a. 284 Dimensions and Weight Width Depth Height Net weight OVER UNDER OVER UNDER OVER UNDER OVER UNDER mm mm mm mm mm mm kg kg Notes (1) Ref. Conditions: Indoor=27°C, 45%UR Outdoor=35°C (2) Measured at a height of 1 m and 1 m from the front of the unit in free field TELECOM SOLUTIONS MED / i-MED 0001÷0091 Packaged air conditioners for telecommunication shelters Free Cooling Unit description Features The MED/i-MED air conditioners for telecommunication shelters are direct expansion packaged systems for outdoor installation. a Structure and panelling in electrogalvanised powder coated steel sheets for maximum resistance to rust. (Peraluman panelling available upon request) a Total reliability and functionality of the compressor and all other components guaranteed by leading companies in the telecoms sector. a Contacts for alarms and the machine's functioning state signals. a Universal terminal board for complete outer control of the PLC unit. a Condensing control for lower noise levels. a Safety pressure switches. a Condensing coil protection grills. a User terminal supplied as standard. a Wide range of accessories for easy and correct installation, and for an efficient air treatment system. a Widespread after sales network Available with cooling capacities from to 2 to 20kW, all the units are fitted with external panelling in electrogalvanised powder coated steel sheets. The units can be fitted with a Free Cooling damper (optional) that ensures 30% annual energy savings compared to a traditional solution. The evaporating fan works on a constant current of 48 Volts to ensure reliable operation even in an emergency situation. MED and i-MED units are available in two different versions: with air flow outlet from the upper side (OVER) or from the bottom (UNDER). Main options a a a a Outdoor Free Cooling Mechanical Over 12 l 13 TELECOMSOLUTIONS Electric heating elements. Serial cards for BMS interconnection. 48V DC power supply for emergency situations. Free Cooling damper with opening from 0 to 100%. Free Cooling Mechanical Under ON/OFF Version MED N° Circuits / N°Compressors Refrigerant Power supply COOLING CAPACITY Total cooling capacity Sensible cooling capacity SHR Compressors power input Evaporator air flow Free-cooling air flow (opt.) Evaporator fan 48 V DC power input (opt.) Evaporator fan AC power input Condenser air flow Condenser fan AC power input Electric heater capacity (opt.) Max. outdoor temperature (BASIC/LT) Min. outdoor temperature (BASIC) Min. outdoor temperature (LT) Outdoor sound pressure level 0001 1/1 R410A 230/1/50 0003 1/1 R410A 230/1/50 0004 1/1 R410A 230/1/50 0011 1/1 R410A 230/1/50 kW m3/h m3/h kW kW m3/h kW kW °C °C °C dB(A) 1,95 1,42 0,73 0,60 300 300 0,04 n.a. 500 0,10 1,00 48 -20 n.a. 49 2,91 2,67 0,92 0,81 700 700 0,18 0,15 1100 0,14 1,00 48 -20 n.a. 52 3,45 2,88 0,83 0,98 700 700 0,18 0,15 1100 0,14 1,00 48 -20 n.a. 52 4,94 4,94 1,00 1,18 1450 1450 0,24 0,26 2500 0,13 1,70 48 -20 -35 52 6,36 5,65 0,89 1,62 1450 1450 0,24 0,26 2500 0,13 1,70 48 -20 -35 52 6,36 5,65 0,89 1,62 1450 1450 0,24 0,26 2500 0,13 1,70 48 -20 -35 52 8,43 6,77 0,80 2,27 1600 1600 0,25 0,26 2500 0,13 1,70 48 -20 -35 52 8,34 6,73 0,81 2,26 1600 1600 0,25 0,26 2500 0,13 1,70 48 -20 -35 52 9,72 9,18 0,94 2,38 2450 2450 0,50 0,48 4000 0,22 3,40 48 -20 -35 54 10,6 9,53 0,90 2,74 2450 2450 0,50 0,48 4000 0,22 3,40 48 -20 -35 54 mm mm mm mm mm mm kg kg 394 n.a. 250 n.a. 900 n.a. 43,5 n.a. n.a. 505 n.a. 394 n.a. 1236 n.a. 75 n.a. 505 n.a. 394 n.a. 1236 n.a. 75 970 976 500(745) 500(745) 1814 1735 160 165 970 976 500(745) 500(745) 1814 1735 180 175 970 976 500(745) 500(745) 1814 1735 180 175 970 976 500(745) 500(745) 1814 1735 175 170 970 976 500(745) 500(745) 1814 1735 175 170 1011 1016 600(850) 600(840) 2115 1935 205 265 1011 1016 600(850) 600(840) 2115 1935 215 270 V/Ph/Hz (1) (1) (1) (1) (2) (3) kW kW 0021 0021 0031 0031 0041 0051 0056 0061 0071 0091 1/1 1/1 1/1 1/1 1/1 1/1 1/1 1/1 1/1 1/1 R410A R410A R410A R410A R410A R410A R410A R410A R410A R410A 230/1/50 400/3N/50 230/1/50 400/3N/50 400/3N/50 400/3N/50 400/3N/50 400/3N/50 400/3N/50 400/3N/50 14,3 12,5 0,88 3,41 3200 3200 0,48 0,48 4900 0,68 3,40 48 -20 -35 58 16,8 14,2 0,85 3,90 3500 3500 0,94 0,93 5900 0,38 3,40 48 -20 -35 62 18,4 14,8 0,81 4,85 3500 3500 0,94 0,93 5900 0,38 3,40 48 -20 -35 62 20,6 16,6 0,81 5,61 3900 3900 0,99 0,91 5900 0,38 3,40 48 -20 -35 62 Dimensions and Weight Width Depth (4) Height Net weight OVER UNDER OVER UNDER OVER UNDER OVER UNDER 1011 1178 1178 1178 1016 1196 1196 1196 600(850) 777(856) 777(856) 777(856) 600(840) 780(1025) 780(1025) 780(1025) 2115 2240 2240 2240 1935 2280 2280 2280 220 290 295 300 275 300 310 325 Inverter Version i-MED N° Circuits / N°Compressors Refrigerant Power supply COOLING CAPACITY Total cooling capacity Sensible cooling capacity SHR Compressors power input Evaporator air flow Free-cooling air flow (opt.) Evaporator fan 48 V DC power input (opt.) Evaporator fan AC power input Condenser air flow Condenser fan AC power input Electric heater capacity (opt.) Max. outdoor temperature (BASIC) Min. outdoor temperature (BASIC) Outdoor sound pressure level V/Ph/Hz (1) (1) (1) (1) (3) kW kW kW m3/h m3/h kW kW m3/h kW kW °C °C dB(A) 0031 0051 0071 1/1 R410A 230/1/50 1/1 R410A 230/1/50 1/1 R410A 400/3N/50 MAX 9,53 7,22 0,76 2,37 1600 1600 0,25 0,26 2500 0,13 MIN 4,34 4,34 1,00 0,75 800 800 0,08 0,20 2500 0,13 MAX 12,6 11,0 0,87 3,18 3200 3200 0,48 0,48 4000 0,68 MIN 4,92 4,92 1,00 0,78 1600 1600 0,14 0,36 4000 0,68 MAX 17,6 15,5 0,88 4,49 3900 3900 0,99 0,91 5900 0,38 MIN 7,96 7,96 1,00 1,18 1950 1950 0,30 0,68 5900 0,38 1,70 48 -20 52 3,40 48 -20 54 3,40 48 -20 62 n.a. 976 n.a. 500 (745) n.a. 1735 n.a. 175 n.a. 1016 n.a. 600 (840) n.a. 1935 n.a. 230 n.a. 1196 n.a. 780 (1025) n.a. 2280 n.a. 310 Dimensions and Weight Width Depth (4) Height Net weight OVER UNDER OVER UNDER OVER UNDER OVER UNDER mm mm mm mm mm mm kg kg Notes (1) Ref. Conditions: Indoor=27°C, 45%UR Outdoor=35°C (2) For MED 0001, 0003 and 0004 free cooling function is available through external extractor accessory (3) Measured at a height of 1 m and 1 m from the front of the unit in free field (4) The dimensions between ( ) include rain proof cover TELECOM SOLUTIONS FKO/FKI FREE COOLER 0021÷0051 Free cooling unit for telecommunication shelters Free Cooling Unit description Features Designed for the cooling of highly technological environments (telecommunication shelters and cabinets), FKO/FKI FREE COOLER units feature an advanced free cooling system that utilises the outdoor air to lower the indoor environment temperature. Outdoor air absorbed from the fan is filtered and then released to the indoor space. a Structure and panelling in electrogalvanised powder coated steel sheets for maximum resistance to rust. a Total reliability and functionality of the compressor and all other components guaranteed by leading companies in the telecoms sector. a 48 VDC EC radial fan with continuous speed modulation. a Class G3 air filter. The unit is available in indoor (FKI) or outdoor versions (FKO), in both cases provided with a waterproof jacket in order to avoid even a drop of water from entering the environment. Directly managed by the PLC controller, the units can been coupled with a MED MID or HED air conditioner or with an inverter unit. This ensures getting the best advantage from the free cooling operation, whenever possible. Main options a Electrical panel for the unit’s stand-alone management. a Clogged filter sensor. a Air prefilter in metal frame. For the stand-alone operation an electrical board kit able to manage the unit and two further pre-existing air conditioners are also available. In pre-existing plants, this solution offers the opportunity to add the free cooling function at a later date. Indoor / Outdoor Indoor 14 l 15 TELECOMSOLUTIONS Outdoor FKI/FKO FREE COOLER VDC power supply Max absorbed power Max air flow Cooling capacity EER Max frontal sound pressure (1) (2) 0021 0041 0051 V W m³/h kW W/W dB(A) 48 220 2300 7,67 34,85 62 48 230 2450 8,17 35,51 65 48 460 3040 10,13 22,03 66 mm mm mm mm mm mm 646 646 955 1237 296 542 646 646 955 1237 296 542 646 646 955 1237 325 542 Dimensions Width Height Depth FKI FKO FKI FKO FKI FKO (3) Notes (1) Ref. Conditions: 27°C indoor temperature -17°C outdoor temperature (2) Measured at a height of 1 m and 1 m from the front of the unit in free field (3) Waterproof jacket is included (LxHxP: 595x580x243) TELECOM SOLUTIONS LED 0010E÷0015E Packaged air conditioners for telecommunication cabinets Free Cooling Unit description Features LED packaged air conditioners for telecommunication shelters are direct expansion solutions for outdoor installation. With capacities from 2.5kW to 5,5kW, the units are fitted with external panels in electrogalvanised powder coated steel sheets or in peraluman panels upon request. a Structure and panelling in electrogalvanised powder coated steel sheets for The units can be fitted with a Free Cooling damper, which offers 30% annual energy savings compared to standard systems. The evaporating section fan can optionally work on direct current at 48V to ensure operation even during emergency situations. LED air conditioners are made to ensure a reliable operation even under extreme environmental conditions with temperatures of up to +46°C. maximum resistance to rust. (Peraluman panelling available upon request) a Total reliability and functionality of the compressor and all other components guaranteed by leading companies in the telecoms sector. Contacts for alarms and the machine's functioning state signals. Universal terminal board for complete outer control of the PLC unity. Condensing control for lower noise levels. Safety pressure switches. Condensing coil protection grills. Wide range of accessories for easy and correct installation, and for a complete and efficient air treatment system. a Both Mechanical and free cooling versions available a Widespread after sales network a Double filter (a pre-filter for external air and one for internal air). a a a a a a Main options a a a a Electric heating elements. Serial cards for BMS interconnection. 48V DC power supply for emergency situations. Modulating Free Cooling damper with opening from 0 to 100% . Outdoor Mechanical 16 l 17 TELECOMSOLUTIONS Free Cooling 0010-0010E LED Power supply V/Ph/Hz 0015-0015E 220/1/50 Total cooling capacity (1) kW 2,5 5,7 Sensible cooling capacity (1) kW 2,2 5,2 Compressor AC power input (1) kW 0,84 1,6 Condenser AC power input kW 0,10 0,40 Evaporator AC power input kW 0,18 0,9 Evaporator fan DC power input (48VDC) (opz.) kW 0,1 0,14 Free cooling air flow (opz.) m3/h 470 1500 Evaporator air flow m3/h 500 1600 Condenser max air flow m3/h 750 2000 Outdoor sound pressure level at 1mt dB(A) 50 53 Outdoor sound pressure level at 5mt dB(A) 36 39 Max outdoor temperature °C 46 46 Electric heating (opz.) kW 1 1,5 Dimensions 0010 0010E 0015-0015E Width mm 600 750 1000 Depth mm 600 750 800 Height mm 353 353 410 LED Notes (1) Ref. Conditions: 27°C indoor temperature, 45%UR, 35°C outdoor temperature “ Experience is by far the best proof” Sir Francis Bacon British Philosopher (1561 - 1626) Climaveneta solutions for telecommunication applications, with their unbeatable advantages in terms of efficiency, quality and reliability, are already the preferred choice in the most challenging and prestigious projects, all around the world and with many major brands. 18 l 19 TELECOMSOLUTIONS TELECOM ITALIA Minera Spence Kyivstar Reggefiber 2015 Various application in Italy 2012 Sierra Gorda - Chile Ukraine 2013 The Netherlands Application: Telecommunications Application: Industrial process Application: Telecommunications Application: Telecommunications Cooling capacity: 28000 kW Cooling capacity: 3094 kW Cooling capacity: 10176 kW Cooling capacity: 7295 kW Installed machines: Over 3500 MED, MID, HED+HCAT, FKI FKO units Installed machines: 130 x HED+HCAT 0041 + 42 x HED+HCAT 0056 + 78 x HED +HCAT 0061 Installed machines: 1600 x MED 0021 Installed machines: 77 x MID 0031/S + 485 x MID 0056/S Mobilis BH Telecom Telefónica Guardia di Finanza 2013 Various applications in Algeria 2014 Various applications in Bosnia and Herzegovina 2015 Various applications in Spain 2015 Lamezia Terme (CZ) - Italy Application: Telecommunications Application: Telecommunications Application: Telecommunications Application: Data center Cooling capacity: 3650 kW Cooling capacity: 1000 kW Cooling capacity: 1680 kW Cooling capacity: 135 kW Installed machines: 433 x MED 0031/S Installed machines: Over 100 units MED, MID, HED + HCAT Installed machines: Over 200 units MED, MID, HED + HCAT Installed machines: 8 x MID 0061 + 2 x MID 0031
* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project
advertisement