T2 24V
KIT PREMIER 24V
con / avec / with / mit
T2 24V
KIT PREMIER 24V
KIT PREMIER 24V Wi-Fi
Operatore
Operateur
Operator
Torantrieb
Operador
Alimentazione
Alimentation
Power Supply
Stromspannung
Alimentacion
Peso max cancello
Poids maxi portail
Max gate weight
Max Torgewicht
Peso máx verja
Coppia max
Couple maxi
Max torque
Max. Drehmoment
Coppia max
230V 50/60Hz
300 kg / 660 lbs
Nm 150
KIT PREMIER 24V
KIT PREMIER 24V Wi-Fi
Codice
Code
Code
Kode
Codigo
AD18010
AD18011
ITALIANO pag. 05 / FRANÇAIS pag. 16 / ENGLISH page 27 / DEUTSCH pag. 37 / ESPAÑOL pag. 48
I
F
ISTRUZIONI DI SICUREZZA IMPORTANTI PER
L’INSTALLAZIONE
ATTENZIONE - PER LA SICUREZZA DELLE PERSONE È IMPORTANTE CHE
VENGANO SEGUITE TUTTE LE ISTRUZIONI
CONSERVARE CON CURA QUESTE ISTRUZIONI
1° -Se non è previsto nel quadro elettronico, installare a monte del medesimo
un’interruttore di tipo magnetotermico (onnipolare con apertura minima dei
contatti pari a 3 mm) che riporti un marchio di conformità alle normative
internazionali. Tale dispositivo deve essere protetto contro la richiusura
accidentale (ad esempio installandolo entro quadro chiuso a chiave).
2° -Per la sezione ed il tipo dei cavi la RIB consiglia di utilizzare un cavo di tipo
H05RN-F con sezione minima di 1,5 mm2 e comunque di attenersi alla norma
IEC 364 e alle norme di installazione vigenti nel proprio Paese.
3° -Posizionamento di un’eventuale coppia di fotocellule: il raggio delle fotocellule
deve essere ad un’altezza non superiore a 70 cm dal suolo e ad una distanza
dal piano di movimento della porta non superiore a 20 cm. Il loro corretto
funzionamento deve essere verificato a fine installazione in accordo al punto
7.2.1 della EN 12445.
4° -Per il soddisfacimento dei limiti imposti dalla EN 12453, se la forza di picco
supera il limite normativo di 400 N è necessario ricorrere alla rilevazione di
presenza attiva sull’intera altezza della porta (fino a 2,5 m max). Le fotocellule
in questo caso sono da applicare come indicato nella norma EN 12445 punto
7.3.2.2).
N.B.: È obbligatoria la messa a terra dell’impianto.
I dati descritti nel presente manuale sono puramente indicativi.
RIB si riserva di modificarli in qualsiasi momento.
Realizzare l’impianto in ottemperanza alle norme ed alle leggi vigenti.
INSTRUCTIONS DE SECURITE IMPORTANTES POUR
L’INSTALLATION
ATTENTION - POUR LA SECURITE DES PERSONNES, IL EST IMPORTANT DE
SUIVRE TOUTES LES INSTRUCTIONS
CONSERVER SOIGNEUSEMENT CES INSTRUCTIONS
1° -Si ce n’est pas prévu dans la centrale, installer en amont de celle-ci un interrupteur
de type magnétothermique (omnipolaire avec ouverture minimum des contacts de 3
mm) qui porte une marque de conformité aux normes internationales. Ce dispositif
doit être protégé contre la re-fermeture accidentelle (par exemple en l’installant
dans un tableau fermé à clé).
2° -En ce qui concerne la section et le type des câbles, RIB conseille d’utiliser un câble
de type H05RN-F ayant une section minumum de 1,5 mm2 et de toute façon, s’en
tenir à la norme IEC 364 et aux normes d’installation en vigueur dans le propre pays.
3° -Positionnement d’un couple éventuel de photocellules: Le rayon des photocellules
doit se situer à une hauteur qui ne doit pas être supérieure à 70 cm du sol et à
une distance du plan de mouvement de la porte qui ne doit pas être supérieure à
20 cm. Leur bon fonctionnement doit être vérifié en fin d’installation selon le point
7.2.1 de la EN 12445.
4° -Pour satisfaire aux limites imposées par la EN 12453, si la force de pointe dépasse
la limite de la norme de 400 N, il est nécessaire de recourir au relevé de présence
active sur la hauteur totale de la porte (jusqu’à 2,5 m max). - Les photocellules,
dans ce cas, doivent être appliquées selon le point 7.3.2.2 de la EN 12445
N.B.: La prise de terre sur l’installation est obligatoire.
Les données décrites dans ce manuel sont purement indicatives.
RIB se réserve le droit de les modifier à tout moment.
Réaliser l’installation en conformité aux normes et aux lois en vigueur.
INSTRUCTIONS IMPORTANTES DE SECURITE POUR L’INSTALLATION
ATTENTION - UNE INSTALLATION NON CORRECTE PEUT CAUSER DE GRAVES
DOMMAGES
SUIVRE TOUTES LES INSTRUCTIONS D’INSTALLATION
1° -Ce livret d’instructions est adressé exclusivement à un personnel spécialisé
qui connaît les critères de construction et les dispositifs de protection contre les
accidents concernant les portails, les portes et les portes cochères motorisés (s’en
tenir aux normes et aux lois en vigueur).
2° -L’installateur devra délivrer à l’utilisateur final un livret d’instruction en accord à la
EN 12635.
3° -L’installateur avant de procéder à l’installation, doit prévoir l’analyse des risques
de la fermeture automatisée finale et la mise en sécurité des points identifiés
dangereux (en suivant les normes EN 12453/EN 12445).
4° -L’installateur, avant d’installer le moteur de mouvement, doit vérifier que le
portail de fer soit en bonnes conditions mécaniques et qu’il s’ouvre et se ferme
correctement.
5° -L’installateur devra installer l’organe pour l’exécution de la relâche manuelle à une
hauteur inférieure à 1,8 m.
6° -L’installateur devra retirer d’éventuels obstacles au mouvement motorisé du portail
de fer (ex. verrous, serrures, etc).
7° - L’installateur devra appliquer, de façon permanente, les étiquettes qui mettent
en garde contre l’écrasement, dans un endroit bien visible ou à proximité de
commandes fixes éventuelles.
8° - Le câblage des divers composants électriques externes à l’opérateur (par exemple
photocellules, clignotants, etc) doit être effectué selon la EN 60204-1 et les
modifications apportées à celle-ci dans le point 5.2.2 de la EN 12453.
9° - Le montage éventuel d’un tableau pour la commande manuelle du mouvement doit
être fait en positionnant le tableau de façon à ce que la personne qui l’actionne ne
se trouve pas en position de danger; de plus, il faudra faire en sorte que le risque
d’actionnement accidentel des boutons soit réduit.
10° - Tenir les commandes de l’automatisme (tableau, télécommande, etc) hors de portée
des enfants. L’organe de manoeuvre (un interrupteur tenu fermé manuellement)
doit être dans une position qui soit visible de la partie guidée mais lointaine des
parties en mouvement. Il doit être installé à une hauteur moindre de 1,5 m.
11° - Cet appareil peut être utilisé par des enfants âgés de 8 ans et plus et les personnes
dont les capacités physiques, sensorielles ou mentales réduites, ou manquant
d’expérience et de connaissances si elles sont sans surveillance ou instruction
concernant l’utilisation de l’équipement en toute sécurité et de comprendre les
risques encourus.
12° - Enfants ne doivent pas jouer avec l’appareil.
13° - Nettoyage et entretien utilisateur n’a pas à être effectué par des enfants sans
surveillance.
14° - Ne laissez pas les enfants jouer avec les commandes fixes. Gardez la télécommande
hors de portée des enfants.
15° - Les dispositifs fixes de commande doivent être installés de sorte qu’ils soient
visibles.
16° - Avant l’exécution de toute opération d’installation, de réglage, d’entretien de
l’installation, couper le courant en agissant sur l’interrupteur magnétothermique à
cet effet, branché en amont de l’installation.
17° - A la fin de l’installation, l’installateur devra s’assurer que les parties de la porte
n’encombrent pas la rue ou le trottoir public.
LA SOCIETE RIB N’ACCEPTE AUCUNE RESPONSABILITE pour d’éventuels
dommages provoqués par la non-observation dans l’installation, des normes de
sécurité et des lois actuellement en vigueur.
ISTRUZIONI IMPORTANTI DI SICUREZZA PER L’INSTALLAZIONE
ATTENZIONE - L’INSTALLAZIONE NON CORRETTA PUÒ CAUSARE GRAVI DANNI
SEGUIRE TUTTE LE ISTRUZIONI DI INSTALLAZIONE
1° -Questo libretto d’istruzioni è rivolto esclusivamente a del personale
specializzato che sia a conoscenza dei criteri costruttivi e dei dispositivi di
protezione contro gli infortuni per i cancelli, le porte e i portoni motorizzati
(attenersi alle norme e alle leggi vigenti).
2° -L’installatore dovrà rilasciare all’utente finale un libretto di istruzioni in accordo
alla 12635.
3° -L’installatore prima di procedere con l’installazione deve prevedere l’analisi
dei rischi della chiusura automatizzata finale e la messa in sicurezza dei punti
pericolosi identificati (seguendo le norme EN 12453 / EN 12445).
4° -L’installatore prima di installare il motore di movimentazione deve verificare
che il cancello sia in buone condizioni meccaniche e che si apra e chiuda
adeguatamente.
5° -L’installatore dovrà installare l’organo per l’attuazione del rilascio manuale ad
un’altezza inferiore a 1,8 m.
6° -L’installatore dovrà rimuovere eventuali impedimenti al movimento motorizzato
del cancello (es. chiavistelli, catenacci, serrature ecc.)
7° -L’installatore dovrà applicare in modo permanente le etichette che mettono in
guardia contro lo schiacciamento in un punto molto visibile o in prossimità di
eventuali comandi fissi.
8° -Il cablaggio dei vari componenti elettrici esterni all’operatore (ad esempio
fotocellule, lampeggianti, ecc.) deve essere effettuato secondo la EN 60204-1
e le modifiche a questa apportate dal punto 5.2.2 della EN 12453.
9° -
L’eventuale montaggio di una pulsantiera per il comando manuale del
movimento deve essere fatto posizionando la pulsantiera in modo che chi la
aziona non si trovi in posizione pericolosa; inoltre si dovrà fare in modo che sia
ridotto il rischio di azionamento accidentale dei pulsanti.
10° -
Tenete i comandi dell’automatismo (pulsantiera, telecomando etc) fuori
dalla portata dei bambini. L’organo di manovra (un interruttore tenuto
chiuso manualmente) deve essere in una posizione che sia visibile dalla parte
guidata ma lontana dalle parti in movimento. Deve essere installato a un’altezza
minima di 1,5 m.
11° -Questo apparecchio può essere utilizzato da bambini di età compresa dagli 8
anni e al di sopra e le persone con ridotte capacità fisiche, sensoriali o mentali,
o mancanza di esperienza e conoscenza se sono stati controllati o istruiti all’uso
dell’apparecchio in modo sicuro e capire i rischi connessi.
12° -I bambini non devono giocare con l’apparecchio.
13° -
Pulizia e manutenzione utente non deve essere fatta da bambini senza
supervisione.
14° -Non permettere ai bambini di giocare con i comandi fissi. Tenere i telecomandi
lontano dai bambini.
15° -I dispositivi di comando fissi devono essere installati in modo che siano visibili.
16° -
Prima di eseguire qualsiasi operazione di installazione, regolazione,
manutenzione dell’impianto, togliere la tensione agendo sull’apposito
interruttore magnetotermico collegato a monte dello stesso.
17° -A fine installazione l’installatore dovrà assicurarsi che le parti della porta non
ingombrino strade o marciapiedi pubblici.
LA DITTA RIB NON ACCETTA NESSUNA RESPONSABILITÀ per eventuali
danni provocati dalla mancata osservanza nell’installazione delle norme di
sicurezza e delle leggi attualmente in vigore.
2
G
B
D
IMPORTANT SAFETY INSTRUCTIONS FOR THE
INSTALLATION
WICHTIGE SICHERHEITS ANLEITUNGEN FÜR DIE
INSTALLATIONEN
ATTENTION - FOR THE SAFETY OF PEOPLE IT IS IMPORTANT TO FOLLOW ALL
THE INSTRUCTIONS
KEEP THESE INSTRUCTIONS WITH CARE
1° - If it is not forecast in the electric gearcase, install a switch of magneto thermic
type upstream, (omni polar with minimum opening of the contacts of 3 mm) with a
check of conformity to the international standards. Such device must be protected
against the accidental lockup (for example by installing inside a locked board).
2° - For the section and the type of the cables RIB advices to use a cable of H05RN-F
type with 1,5 sqmm minimum section and, however, to keep to the IEC 364 and
installation standards in force in your country.
Positioning of a possible couple of photoelectric cells: the radius of the
3° - photoelectric cells must be at a height of no more than 70 cm from the ground
and at a distance not superior to 20 cm from the motion plane of the door. Their
correct working must be verified at the end of the installation in accordance with
the point 7.2.1 of the EN 12445
4° - To fulfill the limits set by EN 12453, and in case the peak force exceeds the
normative limit of 400 N it is necessary to have recourse to the active presence
survey on the whole height of the door (up to max 2,5 m) - The photoelectric cells,
in this case, must be applied in accordance with the point 7.3.2.2 of the EN 12445
N.B.: The earthing of the system is obligatory.
The data described in this handbook are purely a guide.
RIB reserves the right to change them in any moment.
Carry out the system in the respect of the standards and laws in force.
ACHTUNG - FÜR DIE SICHERHEIT DER PERSONEN IST ES WICHTIG, DASS ALLE
ANWEISUNGEN GENAU AUSGEFÜHRT WERDEN
INSTALLATIONSVORSCHRIFTEN BEACHTET WERDEN
1° - Wenn nicht bereits an der elektrischen Schaltzentrale vorgesehen, muss vor der
Schaltzentrale ein thermomagnetischer Schalter installiert werden (omnipolar, mit
einer minimalen Kontaktöffnung von 3 mm), der ein von den internationalen Normen
anerkanntes Konformitätszeichen besitzt. Solch ein Geraet muss vor Vandalismus
geschuetzt werden (z.B.mit einen Schluesselkatsten in einem Panzergehaeuse).
2° - RIB empfiehlt den Kabeltyp H05RN-F mit einem minimalen Querschnitt von 1,5 mm2
generell sollten die Normative IEC 364 und alle anderen geltenden Montagenormen
des Bestimmungslandes eingehalten werden.
3° - Position des ersten paar Fotozellen: Der sollten nicht hoeher als 70 cm vom Boden
sein, und sollte nicht mehr als 20 cm entfernt von der Achse des Tores sitzen (das
gilt fuer Schiebe und Drehtore). In Übereinstimmung mit dem Punkt 7.2.1 der EN
12445 Norm, ihr korrektes Funktionieren muß einmal überprüft werden.
4° - In Einklang mit der Norm EN12453, ist es bei Toren notwendig eine komplette
Sicherheitslieiste zu installieren, bei denen mehr als 400 N Kraft aufgewand werden
muessen, um das Tor zum anhalten zu bringen (Maximum von 2,5 m anwenden) Die Fotozellen müssen in diesem Fall sein beantragen außen zwischen EN 12445
Punkt 7.3.2.2).
ANMERKUNG: Die Erdung der Anlage ist obligatorisch
Die in diesem Handbuch aufgeführten Daten sind ausschließlich empfohlene Werte. RIB
behält sich das Recht vor, das Produkt zu jedem Zeitpunkt zu modifizieren. Die Anlage
muss in Übereinstimmung mit den gültigen Normen und Gesetzen montiert werden.
IMPORTANT SAFETY INSTRUCTIONS FOR THE INSTALLATION
ATTENTION - THE INCORRECT INSTALLATION CAN CAUSE SERIOUS DAMAGES
FOLLOW ALL INSTALLATION INSTRUCTIONS
1° -This handbook is exclusively addressed to the specialized personnel who
knows the constructive criteria and the protection devices against accidents for
motorized gates, doors and main doors (follow the standards and the laws in
force).
2° -The installer will have to issue a handbook to the final user in accordance with
the 12635.
3° -Before proceeding with the installation, the installer must forecast the risks
analysis of the final automatized closing and the safety of the identified
dangerous points (Following the standards EN 12453/EN 12445).
4° -Before installing the motion motor, the installer must verify that the gate is in
good mechanical conditions and that it adequately opens and closes.
5° -The installer must install the member for the manual release at a height inferior
to 1,8 m.
6° -The installer will have to remove possible impediments to the motorized motion
of the gate (eg. door bolts, sliding bolts, door locks etc.)
7° -The installer will permanently have to put the tags warning against the deflection
on a very visible point or near possible fixed controls.
8° -The wiring harness of the different electric components external to the operator
(for example photoelectric cells, flashlights etc.) must be carried out according
to the EN 60204-1 and the modifications to it done in the point 5.2.2 of the EN
12453.
9° -The possible assembly of a keyboard for the manual control of the movement
must be done by positioning the keyboard so that the person operating it
does not find himself in a dangerous position; moreover, the risk of accidental
activation of the buttons must be reduced.
10° -Keep the automatism controls (push-button panel, remote control etc.) out of
the children way. Command device for operating the motor (a switch manually
closed) should be placed in area visible from the guided site and far from moving
parts. It should be placed at least at 1,5 m height.
11° -this appliance can be used by children aged from 8 years and above and persons
with reduced physical, sensory or mental capabilities or lack of experience and
knowledge if they have been given supervision or instruction concerning use of
the appliance in a safe way and understand the hazards involved
12° -children shall not play with the appliance
13° -cleaning and user maintenance shall not be made by children without supervision
14° -do not allow children to play with fixed controls. Keep remote controls away from
children
15° -Fixed command devices should be installed in a well visible way.
16° -Before carrying out any installation, regulation or maintenance operation of the
system, take off the voltage by operating on the special magneto thermic switch
connected upstream.
17° -At the end of the installation, the installer will have to make sure that the parts
of the door do not encumber streets or public sidewalks.
WICHTIGE SICHERHEITS ANLEITUNGEN FÜR DIE INSTALLATIONEN
WARNUNG - UNSACHGEMÄSSE INSTALLATION KANN ZU SCHWEREN
VERLETZUNGEN
ALLE INSTALLATIONSANLEITUNGEN BEFOLGEN
1° - Diese Betriebsanleitung dient ausschließlich dem Fachpersonal, welche
die Konstruktionskriterien und die Sicherheits-Vorschriften gegen Unfälle für Tore,
Türen und automatische Tore kennt (geltende Normen und Gesetze beachten
und befolgen).
2° - Der Monteur muss dem Endkunde eine Betriebsanleitung in Übereinkunft der
EN12635 überreichen.
Vor der Installierung muss für die automatische Schließung und zur
3° - Sicherheitsgewährung der identifizierten kritischen Punkte, eine Risiko Analyse
vorgenommen werden mit der entsprechenden Behebung der identifizierten,
gefährlichen Punkte. (die Normen EN 12453/EN 12445 befolgend).
4° -Vor den Bewegungsmotor zu installieren, ist es nötig die mechanischen Zustande
von der Gittertür (Öffnung, Schluss, u.s.w.) zu prüfen.
5° -Das Element für den manuellen Schiebebetrieb muss bei einer geringeren Höhe
von 1,80 Metern installiert sein.
6° -Der Installateur muss mögliche Verhinderungen an der Gittertürbewegung (wie
z.B. Riegeln, Schlossen u.s.w.) abnehmen.
7° -Der Installateur muss ständige Etiketten, gegen die Zerdrücken Gefahr, auf einen
sehr sichtbaren Punkt oder in der nähe von stationären Steuerungen anbringen.
8° -Die Verkabelung der verschiedenen externen elektrischen Komponenten zum
Operator (z.B. Fotozellen, Blinker etc.) muss nach EN 60204-1 ausgeführt
werden, Änderungen davon nach Punkt 5.2.2 der EN 12453.
9° -Die eventuelle Montage einer Schalttafel für den manuellen Bewegungsbefehl
muss so angebracht werden, dass der Benutzer sich nicht in einer Gefahrenzone
befindet, und dass, das Risiko einer zufälligen nicht gewollten Aktivierung von
Schaltern gering ist.
10° -
Alle Steuerungselemente (Schalttafel, Fernbedienung etc.) gehören nicht in
Reichweite von Kindern. Das Schalten Element (einen Schalter dass manuell
geschlossen ist) muss sichtbar aus dem angetriebenen Teil sein, und muss
entfernt aus dem beweglichen Teil sein. Dies Element muss bei einer Höhe von
wenigsten 1,50 Metern installiert sein.
11° -Die Nutzung von diesem Gerät ist erlaubt an Kinder ab 8 Jahre alte. Es ist
nötig die Personen mit physischen und Intellekt Handikapen, auf die möglichen
Gefahren zu warnen.
12° -Die Kinder muss mit diesem Gerät nicht spielen.
13° -Die Kinder muss die Reinigung und die Wartung von diesem Gerät, ohne Aufsicht,
nicht machen.
14° -Die Kinder muss mit den Steuerungen und mit den Fernsteuerungen nicht
spielen.
15° -Die fixe Steuerungen muss sichtbare nach der Installation sein.
16° -Vor jeglichem Eingriff, sei es Installation, Regulation oder Wartung der Anlage,
muss vorher die Stromzufuhr unterbrochen werden, den dafür bestimmten
Magnetthermo-Schalter drücken, der am Eingang der Anlage installiert ist.
17° -Nach der Installation ist es nötig zu prüfen dass Teile von der Gittertür keinen
Hindernis auf Straße oder Bürgersteige verursachen.
DIE FIRMA RIB ÜBERNIMMT KEINE VERANTWORTUNG für eventuelle Schäden,
die entstehen können, wenn die Installierungsvorschriften die den gültigen
Sicherheitsnormen entsprechen, nicht eingehalten werden.
THE RIB COMPANY DOES NOT ACCEPT ANY RESPONSIBILITY for possible
damages caused by the non observance during the installation of the safety
standards and of the laws in force at present.
3
E
S
IMPORTANTES INSTRUCCIONES DE SEGURIDAD PARA
LA INSTALACIÓN
ATENCIÓN PARA LA SEGURIDAD DE LAS PERSONAS ES IMPORTANTE QUE SE
OBSERVEN TODAS LAS INSTRUCCIONES
CONSERVAR CUIDADOSAMENTE ESTAS INSTRUCCIONES
1° -En el caso de que no sea previsto en la central eléctrica, instalar antes de la
misma, un interruptor de tipo magnetotérmico (omnipolar con una apertura
mínima de los contactos de 3 mm) que dé un sello de conformidad con las
normas internacionales. Este dispositivo tiene que estar protegido contro cierres
accidentales (por ejemplo instalándolo dentro de un panel cerrado a llave).
2° -Para la sección y el tipo de los cables, RIB aconseja utilizar cables de tipo H05RN-F
con sección mínima de 1,5 mm2 e igualmente atenerse a la norma IEC 364 y a las
normas de instalación del propio país.
3° -Posicionamiento eventual de un par de fotocélulas. El rayo de las fotocélulas
no debe estar a más de 70 cm de altura desde el suelo y a una distancia de
la superficie de movimiento de la puerta, no superior a 20 cm. El correcto
funcionamiento tiene que ser controlado al final de la instalación de acuerdo con el
punto 7.2.1 de la EN 12445.
4° -Para lograr satisfascer los límites impuestos por la EN 12453, si la fuerza de punta
supera el límite normativo de 400 N, es necesario recurrir al control de presencia
activa en toda la altura de la puerta (hasta a 2,5m max). - Las fotocélulas en este
caso se deben colocar como indicado en la EN 12445 punto 7.3.2.2.
PS.: Es obligatorio la puesta a tierra del sistema.
Los datos descritos en el presente manual son sólamente indicativos.
RIB se reserva de modificarlos en cualquier momento.
Realizar el sistema respetando las normas y las leyes vigentes.
IMPORTANTES INSTRUCCIONES DE SEGURIDAD PARA LA INSTALACIÓN
CUIDADO: UNA INCORRECTA INSTALACIÓN PUEDE CAUSAR GRAVES DAÑOS
SEGUIR TODAS LAS INSTRUCCIONES DE INSTALACIÓN
1° -Este manual de instrucciones está exclusivamente dirigido a personal
especializado que conozca los criterios de construcción y de los dispositivos
de protección contra accidentes con cancelas, puertas y portales motorizados
(atenerse a las normas y a las leyes vigentes).
2° -El instalador tendrá que dar al utilizador final un manual de instrucciones de
acuerdo con la 12635.
3° -El instalador antes de proceder con la instalación tiene que hacer un analisis de
los riesgos del cierre automatizado final y la puesta en seguridad de los puntos
identificados como peligrosos (siguiendo las normas EN 12453 / EN 12445).
4° -El instalador antes de instalar el motor de desplazamiento tiene que controlar que
la cancela esté en buenas condiciones mecánicas y que se abra y se cierre en
forma adecuada.
5° -El instalador tendrá que instalar el órgano para el desenganche manual a una
altura inferior a 1,8 m.
6° -El instalador tendrá que quitar eventuales impedimentos para el movimiento
motorizado de la cancela (ej. pistillos, cerraduras, cerrojos, etc.).
7° - El instalador tendrá que colocar de modo permanente rótulos que adviertan de la
posibildad de aplastamiento, en un punto bastante visible o en las cercanías de
eventuales mandos fijos.
8° - El cablaje de los varios componentes eléctricos externos al operador (por ejemplo
fotocélulas, los intermitentes, etc) tiene que ser efectuado según la EN 60204-1 y
a las modificas sucesivas aportadas por el punto 5.2.2 della EN 12453.
9° - El eventual montaje de un panel de mandos para la gestión del movimiento manual
tiene que ser efectuado posicionando el panel en modo de que quien lo accione
no se encuentre en una posición peligrosa; además se tiene que hacer en modo
que sea mínimo el riesgo de accionamiento accidental de los pulsadores.
10° - Tener los mandos del automatismo (panel de mandos, mando a distancia, etc.)
lejos del alcance de los niños. El òrgano de maniobra (un interruptor cerrado
manualmente) tiene que estar en una posiciòn visible desde la parte de maniobra,
pero lejana de las piezas en movimiento. Tiene que ser instalado en una altura
mìn. de 1,5 metros.
11° - Esta unidad puede ser utilizado por niños de 8 años o más y las personas con
capacidades físicas, sensoriales o mentales reducidas, o falta de experiencia y
conocimientos que hayan recibido supervisión o instrucciones relativas al uso de
‘equipo de manera segura y comprender los riesgos que implica.
12° - Los niños no deben jugar con el aparato.
13° - Limpieza y mantenimiento de usuarios no tiene que ser hecho por los niños sin
supervisión.
14° - No permita que los niños jueguen con los controles fijos. Mantenga los controles
remotos alejados de los niños.
15° - Los mecanismos de mando fijos tienen que ser instalados de manera visible.
16° - Antes de ejecutar cualquier operación de instalación, ajuste o mantenimiento del
sistema, quitar la corriente accionando el respectivo interruptor magnetotérmico
conectado antes del mismo.
17° - Al final de la instalación, el instalador tendrá que asegurarse de que las partes de
la puerta no estorben calles o aceras públicas.
LA EMPRESA RIB NO SE RESPONSABILIZA por eventuales daños provocados
por la falta de respeto de las normas de seguridad, durante la instalación y de
las leyes actualmente vigentes.
4
I
LAYOUT IMPIANTO
2
7
3
CARATTERISTICHE TECNICHE
PREMIER 24V è un operatore irreversibile utilizzato per movimentare cancelli a
battente con ante lunghe fino a 3 m (Fig. 1).
PREMIER 24V è stato concepito per funzionare senza finecorsa elettrici, ma
solo meccanici.
Quando è arrivato in battuta il motore funziona ancora per qualche secondo, fino
a quando non interviene il timer di funzionamento della centralina di comando
o il sensore di corrente.
4
CARATTERISTICHE
TECNICHE
5
1
6
1
5
4
PREMIER 24V
Lunghezza max. anta
m
3
Peso max cancello
kg
300
Tempo medio di apertura
s.
17
Coppia max di spinta
Nm
1
1 - Operatore PREMIER 24V
2 - Antenna radio
3 - Lampeggiatore
4 - Selettore a chiave
5 - Fotocellule esterne
6 - Chiavistello
7 - Serratura elettrica
150
230V~ 50Hz
Alimentazione e frequenza
Potenza motore
W
Assorbimento
A
0,311
Cicli normativi
n°
∞ - 17s/2s
Cicli consigliati al giorno
n°
Servizio
72
60
80%
Cicli consecutivi garantiti
n°
60/17s
Peso motore
kg
7,5
Rumorosità
db
<70
Volume
m3
0,0184
Temperatura di lavoro
°C
-30 ÷ +55°C
Grado di protezione
IP
44
Misure in mm / inch
5
I
INSTALLAZIONE PREMIER
CONTROLLO PRE-INSTALLAZIONE
Le ante devono essere solidamente fissate ai cardini delle colonne, non devono flettere durante
il movimento e devono muoversi senza attriti.
Prima d’installare PREMIER 24V è meglio verificare tutti gli ingombri necessari per poterlo
installare.
Se il cancello si presenta come da Fig. 1 non occorrono modifiche.
È obbligatorio uniformare le caratteristiche del cancello alle norme e leggi vigenti.
Il cancello può essere automatizzato solo se in buono stato e se rispondente alla norma EN
12604.
- L’anta non deve presentare porte pedonali. In caso contrario occorrerà prendere opportune
precauzioni in accordo al punto 5.4.1 della EN12453 (ad esempio impedire il movimento
del motore quando il portoncino è aperto, grazie ad un microinterruttore opportunamente
collegato in centralina).
- Non bisogna generare punti di intrappolamento (ad esempio tra anta aperta del cancello e
muro laterale).
SBLOCCO DI EMERGENZA A CHIAVE
In caso di mancanza di corrente, per poter agire manualmente sul cancello è sufficiente inserire
l’apposita chiave e ruotarla di 180° in senso orario
(Fig. 2).
Componenti da installare secondo la norma EN12453
USO DELLA CHIUSURA
TIPO DI COMANDO
Persone esperte
(fuori da area
pubblica*)
Persone esperte
(area pubblica)
Uso illimitato
a uomo presente
A
B
non possibile
a impulsi in vista
(es. sensore)
CoE
CoE
C e D, o E
a impulsi non in vista
(es. telecomando)
CoE
C e D, o E
C e D, o E
C e D, o E
C e D, o E
C e D, o E
automatico
* esempio tipico sono le chiusure che non accedono a pubblica via
A: Pulsante di comando a uomo presente (cioè ad azione mantenuta), come cod.
ACG2013
B: Selettore a chiave a uomo presente, come cod. ACG1010
C: Regolazione della forza del motore
D: Coste e/o altri dispositivi di limitazione delle forze entro i limiti della norma EN12453
- Appendice A.
E: Fotocellule, es. cod. ACG8026 (da applicare ogni 60÷70 cm per tutta l’altezza della
colonna del cancello fino ad un massimo di 2,5 m - EN 12445 punto 7.3.2.1)
SBLOCCO DI EMERGENZA CON CASSAFORTE DALL’ESTERNO
In caso di mancanza di corrente, per agire manualmente sul cancello è sufficiente collegare il
cavo d’acciaio con guaina (A) (cod. ACG8022) da un lato alla levetta di sblocco dell’operatore
(B) e dall’altro ad una cassaforte con sblocco (C) cod. ACJ9071 o cod. ACJ9078 (Fig. 3).
ATTENZIONE
Per poter eseguire in modo sicuro la movimentazione manuale dell’anta occorre verificare che:
- sull’anta siano presenti maniglie idonee;
- tali maniglie siano posizionate in modo da non creare punti di pericolo durante il loro utilizzo;
- lo sforzo manuale per muovere l’anta non superi i 225N per i cancelli posti su siti privati ed
i 390N per i cancelli posti su siti commerciali ed industriali (valori indicati nel punto 5.3.5
della norma EN 12453).
N.B.: In caso di cancelli a due ante, per un’efficace chiusura mediante serratura elettrica,
si consiglia l’utilizzo di un chiavistello meccanico (cod. ACG5000). Questo accessorio viene
montato solitamente alla base della prima anta che si chiude. Quando arriva la seconda anta,
questa tocca il chiavistello e blocca cosi la prima anta a terra. La seconda anta rimane invece
bloccata alla prima grazie alla serratura elettrica che monta solitamente a metà altezza.
2
C
B
B
A
3
6
I
FISSAGGIO ATTACCO MOTORE A COLONNA (D)
Durante l’installazione di PREMIER 24V è necessario rispettare alcune misure per avere un corretto movimento dell’anta (vedi fig. 6-8).
X
138
80
80
98
13
D
4
MONTAGGIO LEVE DI TRAINO CON DISPOSITIVO DI BLOCCAGGIO ANTI-INTRUSIONE (E)
Eseguire l’assemblaggio delle leve come da figura 5.
Attenzione: avvitare a fondo le viti V ed W dopodichè per entrambe
eseguire mezzo giro in senso inverso per garantire il corretto movimento
della leva.
Una volta assemblata la leva, sbloccare l’operatore, e fissarla al motore
con la vite M10 e la rondella in dotazione.
V
DRL8x17I
W
DRL10x20I
DRG6I
E
DRL8x17I
DRL8x17I
Il Bloccaggio anti-intrusione (E) impedisce alla leva di muoversi a cancello
chiuso e a motore fermo.
5
FISSAGGIO ATTACCO LEVA CON BLOCCO ANTI-INTRUSIONE (E - FIG. 5)
Sbloccare l’operatore.
Raddrizzare la leva fino a fermo del blocco anti-intrusione (E) e piegarla leggermente in modo che in chiusura non venga sollecitato il blocco (E) in quanto potrebbe rompersi in breve tempo.
α°
90
90
90
A max A max*
140
200
205
190
200
205
90
225
225
95
0
0
90
100
105
110
-
0
0
0
240
0
0
0
X
60
70
80
90
110
70
90
110
155
I
T sec
270
19
160
135
16
140
284
18
315
19
B
130
140
150
180
160
180
225
300
20
230
18
0
15
302
19
322
19
B
A
X
α
I
6
A max* - In caso di utilizzo di un solo fermo in apertura (Fig. 8)
7
I
N.B.: ­In caso di sostituzione della leva, utilizzare una vite M14x20min per
estrarre la vecchia leva dall’albero di traino del PREMIER. È sufficiente
avvitarla nella leva per farla agire da estrattore.
7
REGOLAZIONE FINECORSA MECCANICI
Per posizionare i fermi agire come da schema (Fig. 8).
Per ottenere la chiusura desiderata, a cancello completamente chiuso si dovrà spostare il
fermo (F) contro la leva di traino bloccandolo poi serrando le due viti 6x20 inox ad esagono
incassato con una chiave a brugola n° 5. ATTENZIONE: Usare sempre due viti per ogni fermo.
Per ottenere l’apertura desiderata è sufficiente spostare il fermo (G) e bloccarlo come descritto
per il fermo (F).
ATTENZIONE: La leva di traino del cancello è dotata di un sistema di blocco (E) (Fig. 5) che
deve intervenire solo in caso di intrusione. Se non viene correttamente regolato il fermo di
chiusura, questo sistema interviene ogni volta che il cancello chiude e ciò ne comporta il
danneggiamento in breve tempo.
G
MANUTENZIONE
Da effettuare solamente da parte di personale specializzato dopo aver tolto l’alimentazione
elettrica.
Ogni 6 mesi ingrassare i cardini e controllare le forze di impatto del cancello (EN12453).
F
8
8
T2 24V
T2 24V CRX
COLLEGAMENTI ELETTRICI
cod. AC07088
cod. AC07089
24Vdc 0,8A ± 15% per ACCESSORI
24Vdc 0,8A ± 15% per AUTOTEST COSTE
PEDONALE
PASSO PASSO
SERRATURA
ELETTRICA
FOTOCELLULE
COMUNE
COSTE
LED
LAMPEGGIATORE
24Vdc 20W
R=2,2K 1/4W
ALIMENTAZIONE
230Vac 50Hz
FUSE
T2A
TRASFORMATORE
COMUNE
CHIUDE
APRE
STOP
ANTENNA
CALZA
ANTENNA
M1
M2
9
I
I
A - CONNESSIONI
J1
NF
Alimentazione 230 Vac 50/60 Hz - esterna alla scheda (120V/60Hz a richiesta)
J2
COM.
Comune dei contatti
CLOSE
Contatto impulso di chiusura (NA)
OPEN
Contatto impulso di apertura (NA)
STOP
Contatto impulso di stop (NC)
AERIAL
Antenna radio
SIGNAL
Spia cancello aperto e segnalazione stato di funzionamento
con batteria e batteria scarica (24Vdc 3W max)
A+TEST
Positivo per alimentazione autotest costa
J3
EDGE N.C.
Contatto costa (NC)
COM.
Comune dei contatti
PHOTO N.C.
Contatto fotocellule (NC)
K BUTT.
Contatto impulso singolo (NA)
PED. BUTT.
Contatto comando apertura pedonale (NA)
A+
Positivo per alimentazione accessori a 24Vdc
A-
Negativo per alimentazione accessori a 24Vdc
LOCK
Collegamento elettroserratura (MAX 15W 12V)
J1
J2
F1
J3
TRANSFORMER
J4
FUSE 1
J9
J10
J5
Collegamento fase negativa lampeggiatore a 24Vdc (cod.
ACG7061) Attenzione alle polarità.
J4
SECONDARY
TRANSFORMER
Connettore per secondario trasformatore 18 Vac
J5
MOTOR 1
Collegamento MOTORE 1 (senza polarità)
J6
MOTOR 2
Collegamento MOTORE 2 (senza polarità)
SW T2 24V
Connettore dedicato alla programmazione in fabbrica. NON
TOCCARE IL PONTICELLO! SE VIENE RIMOSSO L’OPERATORE
NON FUNZIONA!
SW RADIO
Connettore dedicato alla programmazione in fabbrica (solo
per modelli CRX). NON TOCCARE IL PONTICELLO! SE VIENE
RIMOSSO L’OPERATORE NON FUNZIONA!
J7
J8
J9
RADIO
Modulo radio incorporato (modello CRX), o connettore per
radio ricevitore RIB ad innesto con alimentazione a 24Vdc
J10
BATTERY
CHARGER
Connettore per scheda di ricarica batteria a 24Vdc (cod.
ACG4648)
TR1
TRIMMER RUN
Trimmer di regolazione dell’alta velocità
TR2
TRIMMER LOW
SPEED
Trimmer di regolazione della bassa velocità
TR3
TRIMMER TCA
Trimmer di regolazione del tempo di attesa prima di avere la
chiusura automatica (DI DEFAULT NON ABILITATO E LED DL6
SPENTO)
B - SETTAGGI
J6
J8
J7
TR3
S3
TR1
DIP 1(ON) - CONTROLLO SENSO DI ROTAZIONE DEL MOTORE (PUNTO C)
DIP 2(ON) - PROGRAMMAZIONE TEMPI (PUNTO D)
DIP 3(ON) - ABILITAZIONE RILASCIO ANTE DURANTE LE FASI DI RALLENTAMENTO,
E IN APERTURA E CHIUSURA TOTALE (PER RISPETTO DELLE PROVE DI
IMPATTO SECONDO EN12453)
DIP 1-2­
MEMORIZZAZIONE/CANCELLAZIONE CODICI RADIO PER COMANDO
APERTURA TOTALE (SOLO MODELLO CRX) (PUNTO E)
DIP 1-3­
MEMORIZZAZIONE/CANCELLAZIONE CODICI RADIO PER COMANDO
APERTURA PEDONALE (SOLO MODELLO CRX) (PUNTO F)
DIP 2-1­
PROGRAMMAZIONE
TEMPI
APERTURA
PEDONALE
MICROINTERRUTTORI DI GESTIONE
DIP 4 F otocellule sempre attive (OFF) - Fotocellule attive solo in chiusura (ON)
DIP 5 Prelampeggio (ON) - Lampeggio normale (OFF)
DIP 6Comando impulso singolo (K BUTT) e Ricevitore radio passo passo (OFF) - automatico
(ON)
DIP 7Funzionamento con sensore di corrente (ON-attivato) Funzionamento a tempo (OFFattivato).
DIP 8Abilitazione serratura elettrica (ON-attivato)
DIP 9Abilitazione colpo di sgancio serratura elettrica (ON-attivata)
DIP 10Abilitazione colpo di aggancio serratura elettrica (ON- attivato)
DIP 11Abilitazione facilitazione sblocco (ON-attivata)
DIP 12Abilitazione TEST monitoraggio costa (ON- attivato ).
S3
PROG
Pulsante per la programmazione
FUSE 1 T 8 A
Fusibile di protezione motori
F1
Fusibile di protezione trasformatore
T2A
TR2
DIP 13Selezione funzionamento con 1 o 2 motori (di default OFF 2 motori)
DIP 14OFF PREMIER 24V CON SERRATURA ELETTRICA
ON PREMIER 24V SENZA SERRATURA ELETTRICA
DIP 15ON
DIP 16CHIUSURA IMMEDIATA DOPO AVER TRANSITATO DAVANTI ALLE
FOTOCELLULE
ONABILITATA
OFFDISABILITATA
JP1 => Verificare che il ponticello sia inserito!
JP2 => Verificare che il ponticello sia inserito!
JP3 => Verificare che il ponticello sia inserito!
PROG => S3 Pulsante per la programmazione
REGOLAZIONI
ATTENZIONE: ABILITARE IL DIP 3 SOLO DOPO AVER ESEGUITO TUTTE LE
PROGRAMMAZIONI.
NOTA: CON DIP 3 (ON) SI ABILITA LA FUNZIONE DI INVERSIONE BREVE DELLE ANTE
DOPO IMPATTO.
QUESTA INVERSIONE BREVE DELLE ANTE PERMETTE DI RIDURRE A ZERO LA FORZA
STATICA ENTRO I 5 SECONDI INDICATI DALLA NORMA EN12453 AL PUNTO A.2.2
10
I
(FORZE STATICHE AMMISSIBILI) CONSENTENDO QUINDI IL RISPETTO DELLE PROVE
DI IMPATTO INDICATE SEMPRE DALLA EN12453).
IN CASO NON SUSSISTA LA NECESSITA’ DI OTTEMPERARE ALLA NORMA SOPRA
DESCRITTA, E’ SUFFICIENTE POSIZIONARE IL DIP 3 IN OFF. IN QUESTO CASO LE
ANTE SI FERMERANNO SENZA INVERTIRE IL MOVIMENTO.
TRIMMER RUN (TR1) Regolatore elettronico dell’alta velocità
Con questo trimmer è possibile regolare la velocità del motore (di default viene settato al
massimo della velocità). La regolazione ha grande utilità per rendere l’automazione conforme
alle norme europee in materia di impatti.
TRIMMER LOW SPEED (TR2) Regolatore elettronico della velocità lenta in
accostamento
La regolazione della velocità lenta viene eseguita agendo sul Trimmer LOW SPEED tramite
il quale si varia la tensione di uscita ai capi del/dei motore/i (ruotandolo in senso orario si
aumenta la velocità). La regolazione viene eseguita per determinare la corretta velocità di fine
apertura e fine chiusura in base alla struttura del cancello o in presenza di leggeri attriti che
potrebbero compromettere il corretto funzionamento del sistema.
TRIMMER DI CHIUSURA AUTOMATICA TCA (TR3) TOTALE O PEDONALE di default
NON ABILITATO e LED DL6 SPENTO (TRIMMER RUOTATO COMPLETAMENTE IN
SENSO ANTIORARIO)
Con questo trimmer è possibile eseguire la regolazione del tempo prima di avere la chiusura
automatica totale o pedonale. Si ottiene solo con porta completamente (totale) o parzialmente
(pedonale) aperta e led DL6 acceso (con trimmer ruotato in senso orario).
Il tempo di pausa può essere regolato da un minimo di 2 secondi ad un massimo di 2 minuti.
SEGNALAZIONI LED
DL1 programmazione attivata (rosso)
DL2 cancello in apertura M2 (verde)
DL3 cancello in chiusura M2 (rosso)
DL4 cancello in apertura M1 (verde)
DL5 cancello in chiusura M1 (rosso)
DL6 segnalazione tempo chiusura automatica (rosso)
DL7 contatto fotocellule (NC) (rosso)
DL8 contatto costa (NC) (rosso)
DL9 comando pulsante STOP (NC) (rosso)
DL10 programmazione codici radio (verde)
e M1. Nello stesso istante il led DL1 smetterà di lampeggiare segnalando l’uscita dalla
procedura di apprendimento.
Da questo momento le sicurezze o altri comandi del cancello funzioneranno normalmente
(inversioni, stop, allarmi, ecc....).
8 - La chiusura delle ante verrà eseguita in modalità veloce (in base a quanto da voi settato
sul trimmer RUN) e in prossimità della totale chiusura in modalità rallentata (in base a
quanto da voi settato sul trimmer LOW SPEED).
9 - Al raggiungimento della chiusura i sensori di corrente fermano il cancello.
10 - A FINE PROGRAMMAZIONE RIMETTERE IL DIP 2 SU OFF.
D - PROGRAMMAZIONE TEMPI PER 1 MOTORE (M1)(#)CON SENSORE
DI CORRENTE ABILITATO (DIP 7 ON)
ATTENZIONE: PER GESTIRE UN SOLO MOTORE IL DIP 13 DEVE ESSERE POSIZIONATO
IN ON DURANTE LA PROGRAMMAZIONE IL SENSORE DI CORRENTE È SEMPRE
ATTIVO.
Il cancello deve essere completamente chiuso.
1 - Mettete DIP 2 su ON => Il led DL1 emetterà dei lampeggi brevi.
2 - Premete il pulsante PROG. => M1 apre.
Raggiunto il fermo meccanico di apertura, il SENSORE DI CORRENTE ferma M1 (con
memorizzazione del tempo e della corrente).
3 - Premete il pulsante PROG. => M1 chiude.
Nello stesso istante il led DL1 smetterà di lampeggiare segnalando l’uscita dalla
procedura di apprendimento. Da questo momento le sicurezze o altri comandi del cancello
funzioneranno normalmente (inversioni, stop, allarmi, ecc....).
Al raggiungimento della chiusura tramite il sensore di corrente il cancello si ferma.
4 - A FINE PROGRAMMAZIONE RIMETTERE IL DIP 2 SU OFF.
(#) DURANTE LA PROGRAMMAZIONE LE SICUREZZE SONO ATTIVE ED IL LORO
INTERVENTO FERMA LA PROGRAMMAZIONE (IL LED DL1 DA LAMPEGGIANTE
RIMANE ACCESO FISSO). PER RIPETERE LA PROGRAMMAZIONE POSIZIONARE IL DIP
2 SU OFF, CHIUDERE IL CANCELLO TRAMITE PROCEDURA “CONTROLLO SENSO DI
ROTAZIONE DEI MOTORI” E RIPETERE LA PROGRAMMAZIONE SCELTA.
D-
PROGRAMMAZIONE TEMPI PER 2
FUNZIONAMENTO A TEMPO (DIP 7 OFF)
FUSIBILI
FUSIBILE DI PROTEZIONE MOTORI
Fuse 1 T 8A
F1 T 2AFUSIBILE DI PROTEZIONE TRASFORMATORE (esterno alla scheda T2 24V)
C - CONTROLLO SENSO DI ROTAZIONE DEL/DEI MOTORE/I
1 - Mettere DIP 1 su ON => Il led DL1 inizia a lampeggiare.
2 - Premere e mantenere premuto il pulsante PROG. (ora il movimento é eseguito ad uomo
presente, apre-stop-chiude-stop-apre-ecc.) => I LED VERDI DL2 e DL4 si accendono
e le ante del cancello si aprono con sfasamento fisso di 2 sec. Se chiudono invece di
aprire, rilasciare il pulsante ed invertire i due fili del motore interessato.
3 - A fine apertura rilasciare il pulsante PROG. ed eseguire la taratura dei fermi meccanici
d’apertura (presenti sull’operatore).
4 - Premere e mantenere premuto il pulsante PROG => I LED ROSSI DL3 e DL5 si
accendono e le ante del cancello si chiudono con sfasamento di 2 sec.
5 - Mantenere premuto il pulsante PROG fino a che il cancello non sia completamente chiuso.
6 - Lasciare le 2 ante completamente chiuse per fare la programmazione tempi.
7 - Rimettere DIP1 su OFF => Il led DL1 si spegne segnalando l’uscita dal controllo.
N.B.: ­Durante questo controllo lo stop, le fotocellule e le coste non sono attive.
D - PROGRAMMAZIONE TEMPI PER 2 MOTORI (#) CON SENSORE DI
CORRENTE ABILITATO (DIP 7 ON)
DURANTE LA PROGRAMMAZIONE IL SENSORE DI CORRENTE È SEMPRE ATTIVO.
1 - Il cancello deve essere completamente chiuso.
2 - Mettete il DIP 2 su ON => Il led DL1 emetterà dei lampeggi brevi.
3 - Premete il pulsante PROG. => M1 apre.
4 - Raggiunto il fermo meccanico di apertura, il SENSORE DI CORRENTE AUTOMATICO ferma
M1 (con memorizzazione del tempo e della corrente)=> Nello stesso momento si attiva
M2 che apre.
5 - Raggiunto il fermo meccanico di apertura, il SENSORE DI CORRENTE AUTOMATICO ferma
M2 (con memorizzazione del tempo e della corrente)
6 - Premete il pulsante PROG. => M2 chiude.
7 - Premete il pulsante PROG. => M1 chiude determinando lo spazio di sfasamento fra M2
MOTORI
(#)
CON
1 - Il cancello deve essere completamente chiuso.
2 - Mettete il microinterruttore DIP 2 su ON => Il led DL1 emetterà dei lampeggi brevi.
3 - Premete il pulsante PROG. => M1 apre.
4 - Raggiunto il fermo meccanico di apertura, dopo un secondo premete il pulsante PROG.
=> M1 si ferma e M2 apre.
5 - Raggiunto il fermo meccanico di apertura => dopo 1 secondo premete il pulsante PROG.
=> M2 si ferma.
6 - Premete il pulsante PROG. => M2 chiude.
7 - Premete il pulsante PROG. => M1 chiude determinando la sfasamento fra M2 e M1.
Nello stesso istante il led DL1 smetterà di lampeggiare segnalando l’uscita dalla
procedura di apprendimento.
Da questo momento le sicurezze o altri comandi del cancello funzioneranno normalmente
(inversioni, stop, allarmi, ecc....).
8 - Finito il conteggio del tempo il cancello si ferma.
9 - A FINE PROGRAMMAZIONE RIMETTERE IL DIP 2 SU OFF.
NOTA: Il rallentamento viene determinato automaticamente dal quadro elettronico in fase di
programmazione tempi, e viene attivato a circa 50÷60 cm prima del raggiungimento
dei finecorsa meccanici di apertura o chiusura.
D-
PROGRAMMAZIONE TEMPI PER 1 MOTORE (#) CON
FUNZIONAMENTO A TEMPO (DIP 7 OFF)
ATTENZIONE: PER GESTIRE UN SOLO MOTORE IL DIP 13 DEVE ESSERE POSIZIONATO
IN ON
1 - Il cancello deve essere completamente chiuso.
2 - Mettete il microinterruttore DIP 2 su ON => Il led DL1 emetterà dei lampeggi brevi.
3 - Premete il pulsante PROG. => M1 apre.
4 - Raggiunto il fermo meccanico di apertura, dopo un secondo premete il pulsante PROG.
=> M1 si ferma.
5 - Premete il pulsante PROG. => M1 chiude.
Nello stesso istante il led DL1 smetterà di lampeggiare segnalando l’uscita dalla
procedura di apprendimento.
Da questo momento le sicurezze o altri comandi del cancello funzioneranno normalmente
(inversioni, stop, allarmi, ecc....).
6 - Finito il conteggio del tempo il cancello si ferma.
7 - A FINE PROGRAMMAZIONE RIMETTERE IL DIP 2 SU OFF.
11
I
D - PROGRAMMAZIONE TEMPI APERTURA PEDONALE (#) SIA PER
FUNZIONAMENTO A TEMPO CHE CON SENSORE DI CORRENTE
A cancello chiuso:
1 - Mettere prima il DIP2 su ON (il led DL1 lampeggia velocemente) e dopo il DIP1 su ON (il
led DL1 lampeggia lentamente).
2 - Premere il pulsante pedonale (COM-PED.BUTT) => M1 apre.
3 - Premere il pulsante pedonale per arrestare la corsa (definendo così l’apertura di M1).
4 - Premere il pulsante pedonale per avviare la chiusura.
5 - Al raggiungimento della chiusura rimettere i DIP1 e 2 su OFF.
(#) DURANTE LA PROGRAMMAZIONE LE SICUREZZE SONO ATTIVE ED IL LORO
INTERVENTO FERMA LA PROGRAMMAZIONE (IL LED DL1 DA LAMPEGGIANTE
RIMANE ACCESO FISSO).
PER RIPETERE LA PROGRAMMAZIONE POSIZIONARE I DIP 1 E 2 SU OFF, CHIUDERE IL
CANCELLO TRAMITE PROCEDURA “CONTROLLO SENSO DI ROTAZIONE DEI MOTORI”
E RIPETERE LA PROGRAMMAZIONE SCELTA.
E - PROGRAMMAZIONE CODICI RADIO APERTURA TOTALE
(62 CODICI MAX - SOLO MODELLI CRX)
La programmazione può essere eseguita solo a cancello fermo.
1 - Posizionare DIP 1 su ON e successivamente il DIP 2 su ON.
2 - Il led rosso DL1 di programmazione lampeggia con frequenza di 1 sec. ON e 1 sec. OFF
per 10 secondi.
3 - Premere il tasto del telecomando (normalmente il canale A) entro i 10 secondi impostati.
Se il telecomando viene correttamente memorizzato il led DL10 (verde) emette un
lampeggio.
4 - Il tempo di programmazione dei codici si rinnova automaticamente per poter memorizzare
il telecomando successivo.
5 - Per terminare la programmazione lasciare trascorrere 10 sec., oppure premere per un
attimo il pulsante PROG. Il led rosso DL1 di programmazione smette di lampeggiare.
6 - Riposizionare DIP 1 su OFF e DIP 2 su OFF.
7 - Fine procedura.
PROCEDURA CANCELLAZIONE DI TUTTI I CODICI RADIO DEDICATI ALL’APERTURA
TOTALE
La cancellazione può essere eseguita solo a cancello fermo.
1 - Posizionare il DIP 1 su ON e successivamente il DIP 2 su ON.
2 - Il led rosso DL1 di programmazione lampeggia con frequenza di 1 sec. ON e 1 sec. OFF
per 10 secondi.
3 - Premere e mantenere premuto il pulsante PROG per 5 secondi. La cancellazione della
memoria viene segnalata da due lampeggi del led verde DL10.
4 - Il led rosso DL1 di programmazione rimane attivo ed è possibile inserire nuovi codici come
da procedure sopra descritte.
5 - Riposizionare DIP 1 su OFF e DIP 2 su OFF.
6 - Fine procedura.
SEGNALAZIONE MEMORIA SATURA CODICI RADIO DEDICATI ALL’APERTURA TOTALE
La segnalazione si può ottenere solo a cancello fermo.
1 - Posizionare il DIP 1 su ON e successivamente il DIP 2 su ON.
2 - Il led verde DL10 lampeggia per 6 volte segnalando memoria satura (62 codici presenti).
3-
Successivamente il led DL1 di programmazione rimane attivo per 10 secondi,
consentendo un eventuale cancellazione totale dei codici.
4 - Riposizionare DIP 1 su OFF e DIP 2 su OFF.
5 - Fine procedura.
F - PROGRAMMAZIONE CODICI RADIO APERTURA PEDONALE
(62 CODICI MAX - SOLO MODELLI CRX)
La programmazione può essere eseguita solo a cancello fermo.
1 - Posizionare DIP 1 su ON e successivamente il DIP 3 su ON.
2 - Il led rosso DL1 di programmazione lampeggia con frequenza di 1 sec. ON e 1 sec. OFF
per 10 secondi.
3 - Premere il tasto del telecomando (normalmente il canale B) entro i 10 secondi impostati.
Se il telecomando viene correttamente memorizzato il led DL10 (verde) emette un
lampeggio.
4 - Il tempo di programmazione dei codici si rinnova automaticamente per poter memorizzare
il telecomando successivo.
5 - Per terminare la programmazione lasciare trascorrere 10 sec., oppure premere per un
attimo il pulsante PROG. Il led rosso DL1 di programmazione smette di lampeggiare.
6 - Riposizionare DIP 1 su OFF e DIP 3 su OFF.
N
OTA: SE IL LED DL1 CONTINUA A LAMPEGGIARE VELOCEMENTE, SIGNIFICA CHE
IL DIP 1 RISULTA ANCORA POSIZIONATO IN ON E QUALSIASI MANOVRA VIENE
NEGATA.
7 - Fine procedura.
PROCEDURA CANCELLAZIONE DI TUTTI I CODICI RADIO DEDICATI ALL’APERTURA
PEDONALE
La cancellazione può essere eseguita solo a cancello fermo.
1 - Posizionare il DIP 1 su ON e successivamente il DIP 3 su ON.
2 - Il led rosso DL1 di programmazione lampeggia con frequenza di 1 sec. ON e 1 sec. OFF
per 10 secondi.
3 - Premere e mantenere premuto il pulsante PROG per 5 secondi. La cancellazione della
memoria viene segnalata da due lampeggi del led verde DL10.
4 - Il led rosso DL1 di programmazione rimane attivo ed è possibile inserire nuovi codici come
da procedure sopra descritte.
5 - Riposizionare DIP 1 su OFF e DIP 3 su OFF.
6 - Fine procedura.
SEGNALAZIONE MEMORIA SATURA CODICI RADIO DEDICATI ALL’APERTURA
PEDONALE
La segnalazione si può ottenere solo a cancello fermo.
1 - Posizionare il DIP 1 su ON e successivamente il DIP 3 su ON.
2 - Il led verde DL10 lampeggia per 6 volte segnalando memoria satura (62 codici presenti).
3-
Successivamente il led DL1 di programmazione rimane attivo per 10 secondi,
consentendo un eventuale cancellazione totale dei codici.
4 - Riposizionare DIP 1 su OFF e DIP 3 su OFF.
5 - Fine procedura.
FUNZIONAMENTO ACCESSORI DI COMANDO
ATTENZIONE: COLLEGARE ACCESSORI DI COMANDO SOLO SE IMPULSIVI.
Assicurarsi che eventuali altri tipi di accessori di comando (per esempio
sensori magnetici) siano programmati nella modalità IMPULSIVA, altrimenti
attiverebbero la movimentazione del cancello senza sicurezze attive.
PULSANTE DI COMANDO PASSO-PASSO (COM-K BUTTON)
Se DIP 6 su OFF =>Esegue un comando ciclico dei comandi apre-stop-chiude-stopapre ecc.
Se DIP 6 su ON =>Esegue l’apertura a cancello chiuso. Se azionato durante il movimento
di apertura non ha effetto. Se azionato a cancello aperto lo chiude e
durante la chiusura se azionato lo fa riaprire.
PULSANTE DI APERTURA (COM-OPEN)
A cancello fermo il pulsante comanda il moto di apertura. Se viene azionato durante la
chiusura fa riaprire il cancello.
FUNZIONE OROLOGIO DEL PULSANTE DI APERTURA
Se desiderate applicare un orologio (o più semplicemente un’interruttore) per
aprire e mantenere aperto il cancello, dovete richiedere T2 24V con fw 03 NOUP.
Se fw 03 o superiore ATTENZIONE: IN CASO DI GUASTO ALLE SICUREZZE, UN
MINUTO DOPO CHE L’OROLOGIO O L’INTERRUTTORE SONO STATI ATTIVATI, IL
CANCELLO SI APRIRA’ SENZA SICUREZZE ATTIVE !
La funzione orologio è utile nelle ore di punta, quando il traffico veicolare risulta rallentato
(es. entrata/uscita operai, emergenze in zone residenziali o parcheggi e, temporaneamente,
per traslochi).
MODALITÁ DI APPLICAZIONE FUNZIONE OROLOGIO
Richiedere T2 24V con firmware 02. Collegando un interruttore e/o un orologio di tipo
giornaliero/settimanale (al posto o in parallelo al pulsante di apertura N.O. “COM-OPEN”),
è possibile aprire e mantenere aperta l’automazione finché l’interruttore viene premuto o
l’orologio rimane attivo. Ad automazione aperta vengono inibite tutte le funzioni di comando.
Rilasciando l’interruttore, o allo scadere dell’ora impostata, si avrà la chiusura immediata
dell’automazione.
PULSANTE DI CHIUSURA (COM-CLOSE)
A cancello fermo comanda il moto di chiusura.
TELECOMANDO
Se DIP 6 su OFF =>Esegue un comando ciclico dei comandi apre-stop-chiude-stopapre-ecc.
Se DIP 6 su ON =>
Esegue l’apertura a cancello chiuso. Se azionato durante il
movimento di apertura non ha effetto. Se azionato con cancello
aperto, lo chiude. Se azionato durante il movimento di chiusura lo fa
riaprire.
PULSANTE APERTURA PEDONALE (COM-PED.BUTT.)
12
I
Comando dedicato ad un’apertura parziale e alla sua richiusura.
Durante l’apertura, la pausa o la chiusura pedonale, è possibile comandare l’apertura da
qualsiasi comando collegato sulla scheda T2 24V. Tramite DIP 6 è possibile scegliere la
modalità di funzionamento del pulsante di comando pedonale.
Se DIP 6 su OFF =>Esegue un comando ciclico dei comandi apre stop-chiude-stop
ecc.
Se DIP 6 su ON =>
Esegue l’apertura a cancello chiuso. Se azionato durante il
movimento di apertura non ha effetto. Se azionato a cancello aperto
lo chiude e durante la chiusura, se azionato, lo fa riaprire.
completa apertura del cancello.
Dopo ogni apertura, la chiusura del cancello viene pertanto consentita solo se la/le costa/e
hanno superato il Test Funzionale.
ATTENZIONE: IL MONITORAGGIO DELL’INGRESSO COSTA PUÒ ESSERE ABILITATO CON IL
DIP 12 IN ON, OPPURE DISABILITATO CON IL DIP 12 IN OFF. INFATTI, IL TEST FUNZIONALE
DELLE COSTE E’ POSSIBILE SOLO NEL CASO SI TRATTI DI DISPOSITIVI DOTATI DI UN
PROPRIO ALIMENTATORE DI CONTROLLO.
UNA COSTA MECCANICA NON PUO’ ESSERE MONITORATA, PERTANTO IL DIP 12 DEVE
ESSERE POSIZIONATO IN OFF.
SERRATURA ELETTRICA (LOCK)
Mettere il DIP 8 su ON per abilitare il comando della serratura elettrica in apertura.
ALLARME DA AUTOTEST COSTA (DIP 12 ON)
A fine apertura se il monitoraggio della costa ha esito negativo, subentra un allarme
visualizzato dal lampeggiatore che rimane acceso, in questa condizione la chiusura del
cancello non viene consentita, solo riparando la costa e premendo uno dei comandi abilitati
e’ possibile ripristinare la normale funzionalità.
COLPO DI SGANCIO SERRATURA ELETTRICA IN APERTURA
Mettere il DIP 9 su ON per abilitare il colpo di sgancio della serratura elettrica in apertura (a
condizione che DIP 8 sia su ON).
A cancello chiuso, se si preme un comando di apertura, il cancello per 0,5s esegue la
manovra di chiusura e contemporaneamente viene attivata la serratura elettrica (seguita da
0,5s di pausa e quindi dall’apertura del cancello).
COLPO DI AGGANCIO SERRATURA ELETTRICA
Mettere il DIP 10 su ON per abilitare il colpo di aggancio della serratura elettrica in chiusura.
A chiusura avvenuta vengono comandati per 0,5s i motori a piena tensione per garantire
l’aggancio della serratura.
FACILITAZIONE SBLOCCO MOTORI
Mettere il DIP 11 su ON per abilitare la facilitazione sblocco manuale (a condizione che il DIP
10 sia su ON), a chiusura avvenuta verrà eseguita una manovra di inversione con un tempo
fisso di 0,2s per facilitare lo sblocco manuale.
FUNZIONAMENTO ACCESSORI DI SICUREZZA
FOTOCELLULA (COM-PHOT)
DIP 4 OFF => A cancello chiuso se un ostacolo è davanti al raggio delle fotocellule, il
cancello non apre. Durante il funzionamento le fotocellule intervengono sia
in apertura (con ripristino del moto in apertura solo dopo la liberazione del
raggio delle fotocellule), che in chiusura (con ripristino del moto inverso solo
dopo la liberazione del raggio delle fotocellule).
DIP 4 ON => A cancello chiuso se un ostacolo è davanti al raggio delle fotocellule e viene
comandata l’apertura, il cancello apre (durante l’apertura le fotocellule non
interverranno). Le fotocellule interverranno solo in fase di chiusura (con
ripristino del moto inverso dopo un secondo anche se le stesse restano
impegnate).
GESTIONE CHIUSURA IMMEDIATA DOPO IL TRANSITO DA FOTOCELLULE
DIP 16 ON e DIP 4 OFF =>Mentre il cancello apre, transitando davanti alle fotocellule il
cancello si ferma. Completato il transito, dopo 1 secondo il
cancello chiude.
DIP 16 ON e DIP 4 ON =>Mentre il cancello apre, transitando davanti alle fotocellule il
cancello continua ad aprire. Completato il transito, il cancello
si ferma e dopo 1 secondo di pausa inverte il moto in
chiusura.
Se si raggiunge la completa apertura (fine tempo di apertura), la chiusura
immediata viene esclusa e viene attivato il tempo di chiusura automatica (se
trimmer TCA abilitato e led DL6 acceso).
Se durante la chiusura si ha un transito veloce (es. pedone) il cancello riaprirà per
due secondi per poi richiudere nuovamente.
DIP 12 OFF => chiusura immediata dopo il transito dalle fotocellule disabilitata.
N.B.: Si raccomanda di verificare la funzionalità delle fotocellule almeno ogni 6 mesi.
EDGE (COSTA) (COM-EDGE)
Durante l’apertura, se impegnata, inverte il moto in chiusura.
Durante la chiusura, se impegnata, inverte il moto in apertura.
Se rimane impegnata dopo il primo impegno, esegue un’ulteriore inversione dopo 2 secondi,
per poi eseguire un’ulteriore piccola inversione e quindi segnalare l’allarme di costa guasta
o impegnata (contatto NO).
Se la costa rimane impegnata (contatto NO) nessuna movimentazione è consentita.
Se non usata, ponticellare i morsetti COM-EDGE.
MONITORAGGIO COSTE DI SICUREZZA (A+TEST A-)
Tramite l’ingresso A+TEST ed il DIP 12 ON è possibile monitorare la/le costa/e.
Il monitoraggio consiste in un Test Funzionale, della costa, eseguito al termine di ogni
PULSANTE DI STOP (COM-STOP)
Durante qualunque operazione il pulsante di STOP esegue il fermo del cancello.
Se premuto a cancello aperto totalmente (o parzialmente utilizzando il comando pedonale) si
esclude temporaneamente la chiusura automatica (se abilitata tramite trimmer TCA e led DL6
acceso). E quindi necessario dare un nuovo comando per farlo richiudere.
Al ciclo successivo la funzione chiusura automatica viene riattivata (se abilitata tramite
trimmer TCA e led DL6 acceso).
ALLARME DA SENSORE DI CORRENTE
La centrale T2 24V è dotata di sensori automatici che fanno invertire la marcia del cancello
nel caso di impatti contro cose o persone in conformità alle norme EN vigenti (verificare
sempre con apposito strumento il rispetto dei valori imposti dalla norma), senza dover
effettuare particolari regolazioni sulla centrale, in quanto gestiti da uno speciale software
interno.
Se dopo un primo intervento del sensore di corrente in apertura o chiusura (solo ad alta
velocità) se ne ha un secondo, ovviamente nel senso contrario, il cancello si ferma e quindi
inverte per 1 secondo. Lo stato di allarme verrà visualizzato dal lampeggiatore che rimarrà
attivo per un minuto, durante questo tempo è possibile ristabilire il funzionamento del
cancello premendo un qualsiasi pulsante di comando.
FUNZIONAMENTO AD UOMO PRESENTE IN CASO DI GUASTO DELLE SICUREZZE
Se la costa è guasta o impegnata per più di 5 secondi, o se la fotocellula è guasta o impegnata
per più di 60 secondi, i comandi APRE, CHIUDE, K BUTTON E PEDONALE funzioneranno solo
ad uomo presente. La segnalazione dell’attivazione di questo funzionamento è data dal led
di programmazione che lampeggia. Con questo funzionamento viene consentita l’apertura o
la chiusura solo mantenendo premuti i pulsanti di comando. Il comando radio e la chiusura
automatica vengono esclusi in quanto il loro funzionamento non è consentito dalle norme.
Al ripristino del contatto delle sicurezze, dopo 1 secondo, viene automaticamente riabilitato
il funzionamento automatico o passo passo e quindi anche il radiocomando e la chiusura
automatica riprendono a funzionare.
Nota 1: durante questo funzionamento in caso di guasto alle coste (oppure fotocellule) le
fotocellule (oppure coste) funzionano ancora interrompendo la manovra in atto.
Nota 2: il pulsante di stop non è considerato una sicurezza da bypassare in questa modalità,
pertanto se viene premuto o è rotto, non consente alcuna manovra.
La manovra a uomo presente è esclusivamente una manovra di emergenza che
deve essere effettuata per brevi periodi e con la sicurezza visiva del movimento
dell’automatismo. Appena possibile le protezioni guaste devono essere ripristinate
per un corretto funzionamento.
LAMPEGGIATORE
N.B.: Questo quadro elettronico può alimentare SOLO LAMPEGGIATORI CON CIRCUITO
LAMPEGGIANTE (ACG7061) con lampade da 24V e 20W massimo.
FUNZIONE PRE-LAMPEGGIO
DIP 5 - OFF => il motore e il lampeggiatore partono contemporaneamente.
DIP 5 - ON => il lampeggiatore parte 3 secondi prima del motore.
SPIA DI SEGNALAZIONE CANCELLO APERTO (COM-SIGNAL)
Ha il compito di segnalare gli stati di cancello aperto, parzialmente aperto o comunque non
chiuso totalmente. Solo a cancello completamente chiuso si spegne.
Durante la programmazione questa segnalazione é attiva.
N.B.: Max 3 W. Se si eccede con le pulsantiere o con le lampade, la logica del quadro
elettronico ne risulterà compromessa con possibile blocco delle operazioni.
FUNZIONAMENTO DOPO BLACK-OUT (SENZA BATTERIE)
Al ritorno della tensione di rete il led DL1 si accende e rimane acceso per tutto il tempo in cui
13
I
il cancello rimane aperto. Si spegnerà al raggiungimento della chiusura totale del cancello.
Si consiglia di far aprire completamente il cancello. Lasciate che il cancello si chiuda da solo
con la chiusura automatica o attendete che il lampeggiatore finisca di lampeggiare prima di
comandare la chiusura.
Questa operazione consentirà al cancello di riallinearsi. Infatti, se durante il black-out i motori
sono stati sbloccati e spostati dalla normale posizione di chiusura, la prima manovra al ritorno
dell’alimentazione deve essere completa.
Se il black-out avviene durante il movimento, o a cancello aperto, e il primo comando risulta
essere quello di chiusura, la chiusura avverrà con sfasamento totale delle ante pertanto prima
chiuderà M2 e allo spegnimento di M2 chiuderà M1. Questo movimento separato dei due
motori eviterà l’accavallamento delle ante.
CARATTERISTICHE TECNICHE
>2,24µV
- Sensibilità
- Tempo eccitazione
300ms
- Tempo diseccitazione
300ms
- Tutti gli ingressi devono essere utilizzati come contatti puliti perchè l’alimentazione è
generata internamente (tensione sicura) alla scheda ed è disposta in modo da garantire il
rispetto di isolamento doppio o rinforzato rispetto alle parti a tensione pericolosa.
- Eventuali circuiti esterni collegati alle uscite del quadro elettronico, devono essere eseguiti
per garantire l’isolamento doppio o rinforzato rispetto alle parti a tensione pericolosa.
- Tutti gli ingressi vengono gestiti da un circuito integrato programmato che esegue un
autocontrollo ad ogni avvio di marcia.
RISOLUZIONE PROBLEMI
- Range di temperatura
0 ÷ 55°C
- Umidita< 95% senza condensazione
- Tensione di alimentazione230V~ ±10% (120V/60Hz a richiesta)
- Frequenza
50/60 Hz
- Alimentazione batteria
20-24VDC
- Potenza Trasformatore130VA
primario 230Vac
secondario 18Vac
- Assorbimento massimo
50 mA
- Microinterruzioni di rete
100ms
- Potenza massima spia cancello aperto24Vdc 3W (equivalente a 1 lampadina
da 3W o 5 led con resistenza in serie da
2,2 KΩ)
- Carico massimo lampeggiatore
24Vdc 20W
- Corrente disponibile per fotocellule e accessori 1A ±15%
- Corrente disponibile su connettore radio
200mA
CARATTERISTICHE TECNICHE RADIO (modello T2 24V crx)
- Frequenza Ricezione
433,92MHz
52Ω
- Impedenza
Dopo aver effettuato tutti i collegamenti seguendo attentamente lo schema ed aver
posizionato il cancello in posizione intermedia, verificare la corretta accensione dei led rossi
DL7, DL8 e DL9.
In caso di mancata accensione dei led, sempre con cancello in posizione intermedia,
verificare quanto segue e sostituire eventuali componenti guasti.
DL7
spento
Fotocellule guaste
DL8spento
Costa sicurezza guasta (In caso la costa non sia collegata, eseguire il
ponticello fra Com e Edge)
Pulsante di Stop guasto (In caso lo Stop non sia collegato, eseguire il
DL9spento
ponticello fra Com e Stop).
Durante il funzionamento a uomo presente, con DIP n° 1 in ON, verificare che durante
l’apertura di M1 e M2 si accendano i led verdi DL2 e DL4 e che durante la chiusura di M1 e
M2 si accendano i led rossi DL3 e DL5.
In caso contrario, invertire i fili del motore interessato.
DIFETTO
SOLUZIONE
Dopo aver effettuato i vari collegamenti e aver dato tensione, tutti i led
sono spenti.
Verificare l’integrità dei fusibili F1, FUSE 1.
In caso di fusibile interrotto usarne solo di valore adeguato.
F1 T 2AFUSIBILE DI PROTEZIONE TRASFORMATORE (esterno alla scheda T2 24V)
FUSE 1 8A FUSIBILE DI PROTEZIONE MOTORI
Il motore apre e chiude, ma non ha forza e si muove lentamente.
Verificare regolazione trimmer RUN e LOW-SPEED.
Il cancello esegue l’apertura, ma non chiude dopo il tempo impostato.
Accertarsi che il trimmer TCA sia abilitato con led DL6 acceso.
Pulsante OPEN sempre inserito, sostituire pulsante o switch del comando OPEN.
Autotest costa fallito, verificare i collegamenti tra quadro elettronico e alimentatore per coste. Attenzione: se
non si stà utilizzando un alimentatore per coste il dip 12 deve essere posizionato in OFF.
Il cancello non apre e non chiude azionando i vari pulsanti K, Radio, Open Contatto costa sicurezza guasto. Contatto fotocellule guasto con DIP 4 OFF.
e Close.
Sistemare o sostituire il relativo contatto.
La serratura elettrica non funziona.
Accertarsi di avere abilitato il DIP 8 in ON.
Il led DL1 lampeggia velocemente e nessuna movimentazione è abilitata.
Posizionare i dip switch 1, 2 o 3 in posizione OFF.
14
OPTIONAL
I
Per i collegamenti ed i dati tecnici degli accessori attenersi ai relativi libretti di istruzione.
LEVA LUNGA
CASSAFORTE STONE
LEVA LUNGA per cancelli con cerniera distante fino a 50 cm dal bordo colonna.
cod. ACG8034
Contenitore di sicurezza per impedire l’agibilità ai dispositivi di comando. Viene fornita
di serie completa di pulsante a bascula (apre-chiude) e sblocco. Necessita del cavo cod.
ACG8022.
In alluminio pressofuso - IP54
cod. ACJ9078
CASSAFORTE FLAT
CAVO PER SBLOCCO
Contenitore di sicurezza per impedire l’agibilità ai dispositivi di comando. Viene fornita
di serie completa di pulsante a bascula (apre-chiude) e sblocco. Necessita del cavo cod.
ACG8022.
In alluminio pressofuso - IP54
cod. ACJ9071
Cavo per sblocco dall’esterno da collegare alla cassaforte.
cod. ACG8022
SERRATURA ELETTRICA
Serratura Orizzontale - destra vista esterna - 12Vac
Serratura Orizzontale - sinistra vista esterna - 12Vac
Serratura Verticale - 12Vac
BATTERIA
cod. ACG8660
cod. ACG8670
cod. ACG8650
Batteria 2,2Ah 12V
cod. ACG9515
T2 24V Wi-Fi
Quadro con sensori di impatto e scheda MASTER Wi-Fi.
Con contenitore.
cod. ABT2025W
15
SCHEDA DI CARICA BATTERIA
cod. ACG4661
F
SCHÉMA DÉTAILLÉ DE L’INSTALLATION
2
7
3
CARACTERISTIQUES TECHNIQUES
PREMIER 24V est un opérateur irréversible utilisé pour faire fonctionner des
portails ayant des battants d’une longueur allant jusqu’à 3 m (Fig. 1).
PREMIER 24V a été conçu pour fonctionner sans fins de course électriques,
mais seulement avec des fins de course mécaniques.
Quand il est arrivé en butée, le moteur fonctionne encore pendant quelques
secondes jusqu’à ce qu’intervienne le timer de fonctionnement de la centrale
de commande ou le détecteur de courant.
4
CARACTERISTIQUES
TECHNIQUES
5
1
6
1
5
4
PREMIER 24V
Longueur maxi du battant
m
3
Poids maxi du portail
kg
300
Temps moyen d’ouverture
s.
17
Couple max de poussée
Nm
1
1 - Operateur PREMIER 24V
2 - Antenne radio
3 - Signal electrique
4 - Selecteur
5 - Photocellules p/protection externe
6 - Verrou
7 - Serrure électrique
150
230V~ 50Hz
Alimentation et frequence
Puissance moteur
W
Absorption
A
0,311
Cycles normatifs
n°
∞ - 17s/2s
Cycles conseillés par jour
n°
Service
72
60
80%
Cycles consécutifs garantis
n°
60/17s
Poids du moteur
kg
7,5
Bruit
db
<70
Volume
m3
0,0184
Temperature de travail
°C
-30 ÷ +55°C
Indìce de protection
IP
44
Mesures en mm / inch
16
F
INSTALLATION PREMIER
CONTROLE PRE-INSTALLATION
Le portail à battant doit être solidement fixé aux cardans des colonnes, ne doit pas flechir pendant
le mouvement et doit pouvoir manoeuvrer sans effort.
Avant d’installer PREMIER 24V, il convient de verifier tous les encombrements necessaires pour
proceder à l’installation. Si le portail se presente comme indiqué Fig. 2, aucune modification
n’est necessaire.
Il est impératif d’uniformiser les caractéristiques du portail avec les normes et les
lois en vigueur. Le portail peut être automatisé seulement si il est en bon état et qu’il est
conforme à la norme EN 12604.
- Le vantail ne doit pas comporter de portillon intégré. Dans le cas contraire, il sera opportun
de prendre les précautions décrites au point 5.4.1 de la EN 12453 (interdire, par le biais
d’un contact raccordé aux bornes adaptées de la platine électronique, la mise en marche de
l’automatisme si le portillon est ouvert).
- Ne pas générer de zone d’écrasement (par exemple entre le vantail ouvert et la cloture).
- Il ne faut pas créer de point d’accrochage (par exemple entre le battant ouvert du portail et
le mur latéral).
DEBLOCAGE D’URGENCE A CLEF
En cas de coupure de courant, pour pouvoir agir manuellement sur le portail, il suffit d’insérer
la clef à cet effet et de la tourner de 180° dans le sens des aiguilles d’une montre (Fig. 2).
Parties à installer conformément à la norme EN12453
USAGE DE LA FERMETURE
TYPE DE COMMANDE
Personne expertes
(au dehors d’une zone
publique*)
Personne expertes
(zone publique)
Usage illimité
homme presente
A
B
non possible
impulsion en vue
(es. capteur)
C ou E
C ou E
C et D, ou E
C ou E
C et D, ou E
C et D, ou E
C et D, ou E
C et D, ou E
C et D, ou E
impulsion hors de vue
(es. boîtier de commande)
automatique
* example typique: fermetures qui n’ont pas d’accès à un chemin public
A: Touche de commande à homme present (à action maintenue), code ACG2013.
B: Sélecteur à clef à homme mort, code ACG1010.
C: Réglage de la puissance du moteur.
D: Barre palpeuse et/ou autres dispositifs de limitation des forces dans les limites de la
norme EN12453- appendice A.
E: Cellules photo-électriques, code ACG8026 (Appliquer chaque 60÷70 cm pour toute
la taille de la colonne de la porte jusqu’à un maximum de 2,5 m - EN 12445 point
7.3.2.1).
DEBLOCAGE D’URGENCE AVEC COFFRE-FORT, DE L’EXTERIEUR
En cas de coupure de courant, pour agir manuellement sur le portail, il suffit de connecter le
câble en acier avec gaine (A) (code ACG8022), d’un côté au levier de déblocage de l’opérateur
(B) et de l’autre, à un coffre-fort avec déblocage (C) code ACJ9071 ou code ACJ9078 (Fig. 3).
ATTENTION
Afin de pouvoir manœuvre manuellement le vantail, il est important de vérifier que:
- Il soit fourni des poignées adaptées sur le vantail;
- Ces poignées doivent être positionnées de sorte à ne pas créer un danger durant leur
utilisation;
- L’effort manuel pour mettre en mouvement le vantail ne doit pas excéder 225N pour les portes
et portails en usage privé, et 390N pour les portes et portails à usage industriel et commercial
(valeurs indiquées au paragraphe 5.3.5 de la norme EN 12453).
N.B.: En cas de portails à deux battants, pour une fermeture efficace par serrure électrique,
nous conseillons d’utiliser un verrou mécanique (code ACG5000). Cet accessoire est monté
habituellement à la base du premier battant qui se ferme. Quand le deuxième battant arrive,
celui-ci touche le verrou et bloque ainsi le premier battant à terre. Le deuxième battant en
revanche reste bloqué au premier grâce à la serrure électrique qui est montée habituellement
à mi-hauteur.
2
C
B
B
A
3
17
F
FIXATION ATTACHE MOTEUR A COLONNE (D)
Durant l’installation de PREMIER 24V, il est nécessaire de respecter certaines mesures pour avoir un mouvement du battant correct (voir fig. 6-8).
X
138
80
80
98
13
D
4
MONTAGE LEVIERS D’ENTRAINEMENT AVEC
DISPOSITIF DE BLOCAGE ANTI-INTRUSION (E)
Effectuer l’assemblage des leviers selon la figure 5.
Attention : Visser les vis V et W à fond, exécuter ensuite pour toutes les
deux un demi tour dans les sens contraire pour garantir le mouvement
correct du levier. Une fois le levier assemblé, débloquer l’opérateur et fixer
le levier au moteur avec la vis M10 et la rondelle fournies.
V
DRL8x17I
W
DRL10x20I
DRG6I
E
DRL8x17I
DRL8x17I
Le Blocage anti-intrusion (E) empêche au levier de se déplacer quand le portail
est fermé et quand le moteur est arrêté.
5
FIXATION ATTACHE LEVIER AVEC BLOCAGE ANTI-INTRUSION (E- FIG. 5)
Débrayer l’opérateur.
Redresser le bras jusqu’à atteindre le blocage anti-intrusion (E), puis le plier légèrement de sorte à ne pas solliciter le verrou (E) à chaque fermeture, car il pourrait être endommagé rapidement.
α°
90
90
90
A max A max*
140
200
205
190
200
205
90
225
225
95
0
0
90
100
105
110
-
0
0
0
240
0
0
0
X
60
70
80
90
110
70
90
110
155
I
T sec
270
19
160
135
16
140
284
18
315
19
B
130
140
150
180
160
180
225
300
20
230
18
0
15
302
19
322
19
B
A
X
α
I
6
A max* - En cas d’utilisation d’une seule butée en ouverture (Fig. 8)
18
F
NB: dans le cas du remplacement du bras, utiliser une vis M14x20 mini
pour extraire l’ancien bras de l’arbre du moteur premier. Il est suffisant de
la visser de sorte à ce qu’elle agisse comme un extracteur.
7
REGLAGE FINS DE COURSE MECANIQUES
Pour positionner les butées, agir comme décrit sur le schéma (Fig. 8).
Pour obtenir la fermeture désirée, quand le portail est complètement fermé, il faudra déplacer
la butée contre le levier d’entraînement en le bloquant et en serrant ensuite les deux vis inox
hexagonales encaissées 6x20 avec une clef Allen n°5.
ATTENTION: Toujours utiliser deux vis pour chaque butée.
Pour obtenir l’ouverture désirée, il suffit de déplacer la butée (G) et de la bloquer comme décrit
pour la butée (F).
ATTENTION: Le levier d’entraînement du portail est doté d’un système de blocage (E)
(Fig. 5) qui doit intervenir seulement en cas d’intrusion. Si la butée de fermeture n’est pas
correctement réglée, ce système intervient à chaque fois que le portail se ferme et ceci en
provoque l’endommagement dans un délai bref.
G
MAINTENANCE
A faire effectuer seulement par un personnel spécialisé après avoir coupé l’alimentation
électrique.
Tous les 6 mois, graisser les gonds et contrôler les forces d’impact du portail (EN12453).
F
8
19
F
T2 24V
T2 24V CRX
BRANCHEMENTS ÉLECTRIQUES
code AC07088
code AC07089
24Vdc 0,8A ± 15% pour ACCESSOIRES
24Vdc 0,8A ± 15% AUTOTEST pour
BARRE PALPEUSE
PIETON
PAS A PAS
SERRURE
ÉLECTRIQUE
PHOTOCELLULES
COMMUN
BARRE PALPEUSE
LED
FEU CLIGNOTANT
24Vdc 20W
R=2,2K 1/4W
ALIMENTATION
230Vac 50Hz
Fusible
T2A
TRANSFORMATEUR
COMMUN
FERMETURE
OUVERTURE
STOP
ANTENNE
ENVELOPPE
ANTENNE
M1
M2
20
F
A - BRANCHEMENTS
J1
NF
Alimentation 230Vac 50/60Hz - externe à la fiche (120V/60Hz sur demande)
J2
COM.
Commun des contacts
CLOSE
Contatto impulso de fermeture (NA)
OPEN
Contatto impulso d’ouverture (NA)
STOP
Contact impulsion de stop (NC)
AERIAL
Antenne radio
SIGNAL
Voyant portail ouvert et signalisation état de fonctionnement
avec batterie et batterie déchargée (24Vdc 3W max)
A+TEST
Positif pour alimentation autotest barre palpeuse
J3
EDGE N.C.
Contact barre palpeuse de sécurité (NC)
COM.
Commun des contacts
PHOTO N.C.
Contact photocellules (NC)
K BUTT.
Contact impulsion simple (NA)
PED. BUTT.
Contact commande ouverture piétonne (NA)
A+
Positif pour alimentation accessoires à 24Vdc
A-
Négatif pour alimentation accessoires à 24 Vdc
LOCK
Connexion électro-serrure (MAX 15W 12V)
J1
J2
F1
J3
TRANSFORMER
J4
FUSE 1
J9
J10
J5
Connexion phase négative clignotant à 24Vdc (code
ACG7061). Attention aux polarités.
J4
SECONDARY
TRANSFORMER
Connecteur pour transformateur secondaire 18 Vac
J5
MOTOR 1
Connexion MOTEUR 1 (sans polarité)
J6
MOTOR 2
Connexion MOTEUR 2 (sans polarité)
SW T2 24V
Connecteur dédié à la programmation en usine. NE PAS
TOUCHER AU CAVALIER! SANS L’OPÉRATEUR, IL NE
FONCTIONNE PAS!
SW RADIO
Connecteur dédié à la programmation en usine. (seulement
pour les modèles CRX) NE PAS TOUCHER AU CAVALIER! SI
LE SYSTÈME RADIO EST ENLEVÉ, IL NE FONCTIONNE PAS!
J7
J8
J7
TR3
S3
J9
RADIO
Module radio incorporé (modèle CRX), ou connecteur pour
radio récepteur RIB à enclenchement avec alimentation à
24Vdc
J10
BATTERY
CHARGER
Connecteur pour fiche de recharge batterie à 24Vdc (code
ACG4648)
TR1
TRIMMER RUN
Trimmer de réglage de la grande vitesse
TR2
TRIMMER LOW
SPEED
Trimmer de réglage de la basse vitesse
TR3
TRIMMER TCA
Trimmer de régulation du temps d’attendue avant avoir la
fermeture automatique (DÉFAUT DÉSHABILITÉ ET LED DL6
ÉTEINT)
B - RÉGLAGES
J6
J8
DIP 1(ON) - COMMANDE SENS DE ROTATION DU MOTEUR (POINT C)
DIP 2(ON) - PROGRAMMATION DES TEMPS (POINT D)
DIP 3
(ON) - ACTIVATION POUR LE RELACHEMENT DES PORTES PENDANT
LES PHASES DE RALLENTISSEMENT, D’OUVERTURE ET DE FERMETURE
COMPLETE (PAR RAPPORT AUX TESTS D’IMPACT SELON LA NORME
EN12453)
DIP 1-2
MEMORISATION/ANNULATION DES CODES RADIO POUR COMMANDE
OUVERTURE COMPLETE (UNIQUEMENT POUR LE MODELE CRX) (POINT E)
DIP 1-3
MEMORISATION/ANNULATION DES CODES RADIO POUR COMMANDE
OUVERTURE COMPLETE (UNIQUEMENT POUR LEMODELE CRX) (POINT F)
DIP 2-1
PROGRAMMATION DES TEMPS D’OUVERTURE PIETONNE AVEC MICROINTERRUPTEURS DE GESTION
DIP 4Photocellules toujours actives (OFF) - Photocellules actives uniquement à la
fermeture (ON)
DIP 5Pré-clignotement (ON) - Clignotement normal (OFF)
DIP 6Commande mono-impulsion (K BUTT) et récepteur radio pas-à-pas (OFF) automatique (ON)
DIP 7fonctionnement avec capteur de courant (ON-activé) Fonctionnement préprogrammé
(OFF-activé)
DIP 8Habilitation de la serrure électrique (ON-activé)
DIP 9Habilitation coup de désenclenchement de la serrure électrique (ON - activé)
TR1
S3
PROG
Bouton pour la programmation
FUSE 1
T8A
Fusible de protection moteur
F1
T2A
Fusible de protection transformateur
TR2
DIP 10Habilitation coup d’enclenchement de la serrure électrique (ON -activé)
DIP 11Habilitation du déblocage assisté (ON-activé)
DIP 12Habilitation du TEST de monitorage de la tranche de sécurité
DIP 13Sélection fonctionnement à 1 ou 2 moteurs (par défaut OFF 2 moteurs)
DIP 14OFF PREMIER 24V AVEC SERRURE ÉLECTRIQUE
ON PREMIER 24V SANS SERRURE ÉLECTRIQUE
DIP 15 ON
DIP 16FERMETURE IMMEDIATE APRES PASSAGE DEVANT LES PHOTOCELLULES
ONACTIVEE
OFFDESACTIVEE
JP1 =>Vérifier que le cavalier est bien inséré!
JP2 =>Vérifier que le cavalier est bien inséré!
JP3 =>Vérifier que le cavalier est bien inséré!
PROG => S3 Bouton pour la programmation
REGLAGES
ATTENTION: POSITIONNER LE DIP 3 SUR ON SEULEMENT APRES AVOIR EFFECTUE
TOUTES LES PROGRAMMATIONS.
REMARQUE: AVEC DIP 3 (en position ON), LA FONCTION D’INVERSION RAPIDE DES
PORTES APRES IMPACT S’ACTIVE.
CETTE INVERSION RAPIDE DES PORTES PERMET D’ANNULER LA FORCE STATIQUE
AVANT LES 5 SECONDES INDIQUEES PAR LA NORME EN12453 ANNEXE A CHAP.
21
F
2.2 (FORCES STATIQUES ADMISSIBLES) RESPECTANT AINSI LES TESTS D’IMPACT
INDIQUES EGALEMENT PAR LADITE NORME. DANS LE CAS OU VOUS NE POURRIEZ PAS
RESPECTER LES PRESCRIPTIONS DE LA NORME 12453, POSITIONNER LE DIP 3 SUR
OFF. DANS CE CAS LES PORTES S’ARRETERONT SANS INVERSER LE MOUVEMENT.
TRIMMER RUN (TR1) Régulateur électronique de vitesse
Avec ce trimmer il est possible de régler la vitesse du moteur (par défaut il est positionné sur
la vitesse maximale). Le réglage est très utile pour rendre l’automatisme conforme aux normes
européennes en matière d’impacts.
TRIMMER LOW SPEED (TR2) Régulateur électronique de vitesse en approche.
Le réglage de la vitesse lente s’effectue en agissant sur le trimmer LOW SPEED par
l’intermédiaire duquel il est possible de varier la tension de sortie sur le(s) moteur(s) (en
le tournant dans le sens des aiguilles d’une montre, la vitesse augmente). Le réglage est
nécessaire afin de déterminer la bonne vitesse en fin d’ouverture ainsi qu’en fin de fermeture
en fonction de la structure du portail ou en présence de légers frottements qui pourraient
compromettre le bon fonctionnement du système.
TRIMMER DE FERMETURE AUTOMATIQUE TCA (TR3) TOTALE OU PIETONNE NON
HABILITE par défaut et DEL DL6 ETEINTE (TRIMMER COMPLETEMENT REGLE DANS LE
SENS INVERSE DES AIGUILLES D’UNE MONTRE)
Avec ce trimmer, il est possible d’effectuer le réglage du temps de pause avant la fermeture
complète ou piétonne. Ce temps de pause s’active seulement avec une porte totalement ou
partiellement ouverte (piétonne) et avec la DEL DL6 allumée ( le trimmer doit être réglé dans le
sens des aiguilles d’une montre). Le temps de pause peut varier de 2 secondes à 2 minutes,
selon le réglage.
SIGNALISATIONS LED
DL1 programmation active (rouge)
DL2 portail en phase d’ouverture M2 (vert)
DL3 portail en phase de fermeture M2 (rouge)
DL4 portail en phase d’ouverture M1 (vert)
DL5 portail en phase de fermeture M1 (rouge)
DL6 signalisation temps de fermeture automatique (rouge)
DL7 contact photocellules (NC) (rouge)
DL8 contact tranche de sécurité (NC) (rouge)
DL9 commande bouton STOP (NC) (rouge)
DL10 programmation codes radio (vert)
6 - Lorsque le pressoir PROG est enfoncé => M2 ferme.
7 - Lorsque le pressoir PROG est enfoncé => M1 ferme en déterminant l’écart de décalage
entre M2 et M1. Au même moment la DEL DL1 s’arrêtera de clignoter indiquant la fin de
la procédure d’apprentissage.
A partir de ce moment, les sécurités ou les autres commandes du portail fonctionneront
normalement (inversions, arrêt, alarmes, etc.).
8 - La fermeture des portes sera effectuée en mode rapide (et à l’approche de la fermeture
totale en mode ralenti (selon ce qui aura été établi sur le trimmer LOW SPEED)
9 - A la fermeture totale, les détecteurs de courant arrêtent le portail.
10 - A LA FIN DE LA PROGRAMMATION REMETTRE LE DIP 2 SUR OFF.
D - PROGRAMMATION DES TEMPS POUR 1 MOTEUR (M1) (#) AVEC
CAPTEUR DE COURANT ACTIVE (DIP 7 ON)
ATTENTION: POUR NE GERER QU’UN MOTEUR LE DIP 13 DOIT ETRE POSITIONNE SUR
ON. PENDANT LA PROGRAMMATION LE DETECTEUR DE COURANT EST TOUJOURS
ACTIVE.
Le portail doit être totalement fermé.
1 - Mettez DIP 2 sur ON => la DEL DL1 émettra des clignotements brefs.
2 - Appuyez sur le pressoir PROG => M1 s’ouvre.
Une fois l’arrêtoir mécanique d’ouverture rejoint, le DETECTEUR DE COURANT arrête M1
(avec mémorisation du temps et du courant).
3 - Appuyez sur le pressoir PROG => M1 se ferme.
Au même moment la DEL DL1 s’arrêtera de clignoter indiquant la fin de la procédure
d’apprentissage. A partir de ce moment, les sécurités ou les autres commandes
fonctionneront normalement (inversions, arrêts, alarmes, etc.).
A la fermeture complète, le portail s’arrête grâce au détecteur de courant.
4 - A LA FIN DE LA PROGRAMMATION REMETTRE DIP 2 SUR OFF.
(#) PENDANT LA PROGRAMMATION LES SECURITES SONT ACTIVEES ET ARRETENT LA
PROGRAMMATION (LA LED DL1, QUI CLIGNOTAIT, RESTE ALLUMEE). POUR REPETER
LA PROGRAMMATION POSITIONNER DIP 2 SUR OFF, FERMER LE PORTAIL GRACE A
LA PROCEDURE “CONTROLE SENS DE ROTATION DES MOTEURS” ET REPETER LA
PROGRAMMATION CHOISIE.
D-
PROGRAMMATION DES TEMPS POUR 2 MOTEURS (#) AVEC
FONCTIONNEMENT PREPROGRAMME (DIP 7 OFF)
FUSIBLES
Fuse 1 T 8A FUSIBLE DE PROTECTION DES MOTEURS
F1 T 2A
FUSIBLE DE PROTECTION DU TRANSFORMATEUR (extérieur à la carte T2 24V)
C - CONTRÔLE DU SENS DE ROTATION DU/DES MOTEUR/S
1 - Mettre DIP 1 sur ON => la DEL DL1 commence à clignoter.
2 - Presser et maintenir enfoncé le poussoir PROG (le mouvement est alors effectué en
présence de l’utilisateur,, avec séquence ouvrir-stopper-fermer-stopper-ouvrir-etc.) =>
les DEL vertes DL2 et DL4 s’allument et le portail s’ouvre avec un décalage constant de 2
sec. S’il se ferme au lieu de s’ouvrir; relâcher le bouton-poussoir et inverser les deux fils
du moteur en question.
3 - A la fin de l’ouverture, relâcher le pressoir PROG et effectuer la mise au point des arrêtoirs
mécaniques d’ouverture (présents sur l’opérateur).
4 - Pousser et maintenir enfoncé le pressoir PROG => LES DEL ROUGES DL3 et DL5 s’allument
et le portail se ferme avec un décalage de 2 sec.
5 - Maintenir enfoncé le pressoir PROG jusqu’à ce que le portail ne soit complètement fermé.
6 - Laisser les deux portes totalement fermées pour effectuer la programmation des temps.
7 - Repositionner DIP 1 sur OFF => la DEL DL1 s’éteint indiquant la sortie de la procédure
du contrôle.
N.B.: Pendant ce contrôle, l’arrêt d’urgence, les photocellules et les tranches de
sécurité ne sont pas activés.
D-
PROGRAMMATION DES TEMPS POUR 2 MOTEURS (#) AVEC
DETECTEUR DE COURANT ACTIVE (DIP 7 ON)
PENDANT LA PROGRAMMATION LE DETECTEUR DE COURANT EST TOUJOURS ACTIF.
1 - Le portail doit être totalement fermé.
2 - Mettez le DIP 2 sur ON => la DEL DL1 émettra des clignotements brefs.
3 - Appuyez le pressoir PROG => la porte M1 s’ouvre.
4 - Une fois l’arrêtoir mécanique d’ouverture rejoint, le DETECTEUR DE COURANT AUTOMATIQUE
arrête M1 (avec mémorisation du temps et du courant) => En même temps la porte M2
s’active et s’ouvre.
5 - Une fois l’arrêtoir mécanique d’ouverture rejoint, le DETECTEUR DE COURANT AUTOMATIQUE
arrête M2 (avec mémorisation du temps et du courant).
1 - Le portail doit être totalement fermé.
2 - Mettez le micro-interrupteur DIP 2 sur ON => la DEL DL1 clignotera rapidement.
3 - Appuyez sur le pressoir PROG => M1 s’ouvre.
4 - Une seconde après que l’arrêtoir mécanique d’ouverture a été rejoint, appuyez sur le
pressoir PROG. => M1 s’arrête et M2 s’ouvre.
5 - Une seconde après que l’arrêtoir mécanique d’ouverture a été rejoint, appuyez sur le
pressoir PROG. => M2 s’arrête.
6 - Appuyez sur le pressoir PROG => M2 se ferme.
7 - Appuyez sur le pressoir PROG => M1 se ferme en déterminant le décalage entre M2 et M1.
Au même moment la DEL DL1 s’arrêtera de clignoter indiquant la fin de la procédure
d’apprentissage.
A partir de ce moment, les sécurités ou les autres commandes du portail fonctionneront
normalement (inversions, stops, alarmes, etc.).
8 - Fini le compte à rebours le portail s’arrête.
9 - A LA FIN DE LA PROGRAMMATION REMETTRE LE DIP 2 SUR OFF.
REMARQUE: Le ralentissement est déterminé automatiquement par le tableau électronique
en phase de programmation des temps et est activé environ 50-60 cm avant que les fins de
courses mécaniques d’ouverture et de fermeture soient rejoints.
D-
PROGRAMMATION DES TEMPS POUR 1 MOTEUR (#) AVEC
FONCTIONNEMENT PREPROGRAMME (DIP 7 OFF)
ATTENTION: POUR NE GERER QU’UN SEUL MOTEUR LE DIP 13 DOIT ETRE POSITIONNE
SUR ON
1 - Le portail doit être totalement fermé.
2 - Mettez le micro-interrupteur DIP 2 sur ON => la DEL DL1 émettra des clignotements brefs.
3 - Appuyez sur le pressoir PROG => M1 s’ouvre.
4 - Une seconde après que l’arrêtoir mécanique d’ouverture a été rejoint, appuyez sur le
pressoir PROG. => M1 s’arrête.
5 - Appuyez sur le pressoir PROG => M1 se ferme.
Au même moment la DEL DL1 s’arrêtera de clignoter indiquant la fin de la procédure
d’apprentissage.
A partir de ce moment, les sécurités ou les autres commandes du portail fonctionneront
normalement (inversions, stops, alarmes, etc.).
8 - Fini le compte à rebours le portail s’arrête.
9 - A LA FIN DE LA PROGRAMMATION REMETTRE LE DIP 2 SUR OFF.
22
F
D-
PROGRAMMATION DES TEMPS D’OUVERTURE PIETONNE (#) EN
FONCTIONNEMENT PREPROGRAMME OU AVEC DETECTEUR DE
COURANT
Une fois le portail fermé:
1 - Mettre d’abord le DIP 2 sur ON (la DEL DL1 clignote rapidement) et ensuite le DIP1 sur ON
(la DEL DL1 clignotera lentement).
2 - Appuyer sur le bouton-pressoir piéton (COM-PED-BUTT) => M1 s’ouvre.
3 - Appuyer sur le bouton-pressoir piéton pour arrêter la course (définissant ainsi l’ouverture
de M1).
4 - Appuyez sur le bouton-pressoir piéton pour démarrer la fermeture.
5 - Au moment de la fermeture, remettre les DIP 1 et 2 sur OFF.
(#) PENDANT LA PROGRAMMATION, LES SECURITES SONT ACTIVEES ET ARRETENT LA
PROGRAMMATION (LA DEL DL1, QUI CLIGNOTAIT, RESTE ALLUMEE).
POUR REPETER LA PROGRAMMATION, POSITIONNER LES DIP 1 ET 2 SUR OFF, FERMER
LE PORTAIL EN SUIVANT LA PROCEDURE “CONTROLE SENS DE ROTATION DES
MOTEURS” ET REPETER LA PROGRAMMATION CHOISIE.
E - PROGRAMMATION DES CODES RADIO POUR OUVERTURE TOTALE
(62 CODES MAXIMUM - UNIQUEMENT POUR LES MODELES CRX)
La programmation ne peut se faire que lorsque le portail est fermé.
1 - Positionner DIP 1 sur ON, puis le DIP 2 sur ON.
2 - La DEL rouge DL1 de programmation clignote avec une fréquence de 1 sec. ON et 1 sec.
OFF pendant 10 secondes.
3 - Appuyer sur la touche de la télécommande (normalement le canal A) dans les 10 secondes.
Si la télécommande est correctement mémorisée la DEL DL10 (verte) émet un clignotement.
4 - Le temps de programmation des codes se renouvelle automatiquement pour pouvoir
mémoriser la télécommande suivante.
5 - Pour terminer la programmation, laisser s’écouler 10 sec, ou bien appuyer pendant un
moment sur le pressoir PROG. La DEL rouge DL1 de programmation arrête de clignoter.
6 - Repositionner DIP 1 sur OFF et DIP 2 sur OFF.
7 - Fin de la procédure.
PROCEDURE D’EFFACEMENT DE TOUS LES CODES RADIO RESERVES A L’OUVERTURE
TOTALE
L’effacement ne peut s’effectuer que lorsque le portail est fermé.
1 - Positionner le DIP 1 sur ON et ensuite le DIP 2 sur ON.
2 - La DEL rouge DL1 de programmation clignote avec une fréquence de 1 sec. ON et 1 sec.
OFF pendant 10 secondes.
3 - Enfoncé et maintenir appuyé le pressoir PROG pendant 5 secondes. L’effacement de la
mémoire est indiquée par deux clignotements de la DEL verte DL10.
4 - La DEL rouge DL1 de programmation reste active et il est impossible d’insérer de nouveaux
codes comme dans la procédure décrite ci-dessus.
5 - Repositionner DIP 1 sur OFF et DIP 2 sur OFF.
6 - Fin de la procédure.
SIGNALISATION MEMOIRE SATUREE CODES RADIO RESERVES A L’OUVERTURE TOTALE
La signalisation ne s’obtient que lorsque le portail est fermé.
1 - Positionner le DIP 1 sur ON et ensuite le DIP 2 sur ON.
2 - La DEL verte DL10 clignote 6 fois, indiquant la saturation de la mémoire (62 codes présents).
3 - Ensuite la DEL DL1 de programmation reste active pendant 10 secondes, rendant possible
l’effacement total des codes.
4 - Repositionner DIP 1 sur OFF et DIP 2 sur OFF.
5 - Fin de la procédure.
F - PROGRAMMATION CODES RADIO OUVERTURE PIETONNE
(62 CODES
MAXIMUM - UNIQUEMENT POUR LES MODELES CRX)
1 - Positionner DIP 1 sur ON et ensuite DIP 3 sur ON.
2 - La DEL rouge DL1 de programmation clignote avec une fréquence de 1 sec. ON et 1 sec.
OFF pendant 10 secondes.
3 - Appuyer sur la touche de la télécommande (normalement sur le canal B) dans les 10
secondes. Si la télécommande est correctement mémorisée la DEL DL10 (verte) émet un
clignotement.
4 - Le temps de programmation des codes se renouvelle automatiquement pour pouvoir
mémoriser la télécommande suivante.
5 - Pour terminer la programmation, laisser s’écouler 10 sec, ou bien appuyer pendant un
instant sur le pressoir PROG. La DEL rouge DL1 de programmation arrête de clignoter.
6 - Repositionner DIP 1 sur OFF et DIP 3 sur OFF.
REMARQUE: SI LA DEL DL1 CONTINUE DE CLIGNOTER RAPIDEMENT, CELA SIGNIFIE
QUE LE DIP 1 EST ENCORE SUR LA POSITION ON ET QUE N’IMPORTE QUELLE
MANŒUVRE SERA REFUSEE.
7 - Fin de la procédure.
PROCEDURE D’EFFACEMENT DE TOUS LES CODES RADIO RESERVES A L’OUVERTURE
PIETONNE
L’effacement ne peut s’effectuer que lorsque le portail est fermé.
1 - Positionner le DIP 1 sur ON et ensuite le DIP 3 sur ON.
2 - La DEL rouge DL1 de programmation clignote avec une fréquence de 1 sec. On et 1 sec.
OFF pendant 10 secondes.
3 - Enfoncer et maintenir appuyé le pressoir PROG pendant 5 secondes. L’effacement de la
mémoire est indiqué par deux clignotements de la DEL verte DL10.
4 - La DEL rouge DL1 de programmation reste active et il est possible d’insérer des nouveaux
codes comme dans la procédure décrite ci-dessus.
5 - Repositionner DIP1 sur OFF et DIP3 sur OFF.
6 - Fin de la procédure.
SIGNALISATION MEMOIRE SATUREE CODES RADIO RESERVES A L’OUVERTURE
PIETONNE
La signalisation ne s’obtient que lorsque le portail est fermé.
1 - Positionner le DIP 1 sur ON et ensuite le DIP 3 sur ON.
2 - La DEL verte DL clignote 6 fois indiquant la saturation de la mémoire (62 codes présents).
3 - Puis la DEL DL1 de programmation reste active pendant 10 secondes, rendant possible
l’effacement total des codes.
4 - Repositionner DIP 1 sur OFF et DIP 3 sur OFF.
5 - Fin de la procédure.
FONCTIONNEMENT DES ACCESSOIRES DE COMMANDE
ATTENTION: CONNECTER LES ACCESSOIRES A COMANDE SEULEMENT SI
IMPULSIVE. Faire attention que des autres accessoires pour le commande
(p.e. senseurs magnétique) sont programmée avec modalité IMPULSIVE, ou
contraire, le mouvement est sans sécurité.
POUSSOIR DE COMMANDE PAS-A-PAS (COM-K BUTTON)
DIP 6 OFF =>Il effectue une commande cyclique des commandes ouvrir - stopper - fermer
- stopper - ouvrir etc.
DIP 6 ON =>Il effectue l’ouverture, quand le portail est fermé. S’il est actionné pendant le
mouvement d’ouverture, cela ne produit aucun effet. S’il est actionné lorsque le
portail est ouvert, il le ferme. S’il est actionné pendant la fermeture du portail,
il le rouvre.
POUSSOIR D’OUVERTURE (COM-OPEN)
Lorsque le portail est fermé, le poussoir commande le mouvement d’ouverture. S’il est actionné
pendant la fermeture du portail, il le rouvre.
FONCTION HORLOGE DU POUSSOIR D’OUVERTURE
Si on désire appliquer une horloge (ou plus simplement un interrupteur) pour
ouvrir et maintenir le portail ouvert, il faut demander T2 24V avec fw 03 NOUP.
Si fw 03 ou supérieur ATTENTION: EN CAS DE DEFAUT DES SECURITES, LE
PORTAIL S’OUVRIRA SANS SECURITES ACTIVES UNE MINUTE APRES QUE
L’HORLOGE OU L’INTERRUPTEUR ONT ETE ACTIVES!
Cette fonction est utile dans les heures de pointe, quand la circulation est ralentie (ex. entrée/
sortie des ouvriers, urgences en zone résidentielle ou dans les parkings et, occasionnellement,
pendant les déménagements).
MODALITÉ D’APPLICATION FONCTION HORLOGE
Demander T2 24V avec firmware 02. En connectant un interrupteur et/ou une horloge de
type quotidien/hebdomadaire (à la place ou en parallèle du poussoir d’ouverture N.O. “COMOPEN”), il est possible d’ouvrir et de maintenir l’automatisme ouvert tant que l’interrupteur est
enfoncé ou que l’horloge reste active. Lorsque l’automatisme est ouvert, toutes les fonctions
de commandes sont bloquées. En relâchant l’interrupteur, ou au terme de l’heure fixée,
l’automatisme se fermera immédiatement.
POUSSOIR DE FERMETURE (COM-CLOSE)
Lorsque le portail est fermé, il commande le mouvement de fermeture.
TELECOMMANDE
DIP 6 OFF =>Il effectue une commande cyclique des commandes ouvrir - stopper - fermer
- stopper - ouvrir etc.
DIP 6 ON =>Il effectue l’ouverture, quand le portail est fermé. S’il est actionné pendant le
mouvement d’ouverture, cela ne produit aucun effet. S’il est actionné lorsque le
portail est ouvert, il le ferme. S’il est actionné pendant la fermeture du portail,
il le rouvre.
23
F
BOUTON OUVERTURE PIETONNE (COM-PED-BUTT)
Commande réservée à l’ouverture partielle et à la refermeture.
Pendant l’ouverture, la pause ou la fermeture piétonne, il est possible de commander
l’ouverture depuis n’importe quelle commande raccordée à la carte T2 24V.
Par l’intermédiaire du DIP 6, il est possible de choisir le mode de fonctionnement du bouton
de commande piétonne.
DIP 6 OFF =>Il effectue une commande cyclique des commandes ouvrir - stopper - fermer
- stopper - ouvrir etc.
DIP 6 ON =>Il effectue l’ouverture, quand le portail est fermé. S’il est actionné pendant le
mouvement d’ouverture, cela ne produit aucun effet. S’il est actionné lorsque
le portail est ouvert, il le ferme. S’il est actionné pendant la fermeture du
portail, il le rouvre.
VERROULLAGE ELECTRIQUE (LOCK)
Mettre le DIP 8 sur ON pour activer la commande de verrouillage électrique en phase
d’ouverture.
COUP DE DESENCLENCHEMENT DE LA SERRURE ELECTRIQUE EN OUVERTURE
Mettre le DIP 9 sur ON pour activer le coup de désenclenchement de la serrure électrique en
ouverture (à condition que le DIP 8 soit sur ON).
Lorsque le portail est fermé, si une commande d’ouverture est engagée, le portail effectue la
manœuvre de fermeture pendant 0,5s et en même temps la serrure électrique est activée(suivi
par 0,5s de pause et ensuite par l’ouverture du portail).
COUP D’ENCLENCHEMENT DE LA SERRURE ELECTRIQUE
Mettre le DIP 10 sur ON pour activer le coup d’enclenchement de la serrure électrique en phase
de fermeture. Une fois la fermeture terminée, les moteurs sont commandés à pleine tension
pour garantir l’enclenchement de la serrure.
FACILITATION DU DEBLOCAGE DES MOTEURS
Mettre le DIP 11 sur ON pour activer la facilitation au déblocage manuel (à condition que le
DIP 10 soit positionné sur ON), une fois la fermeture terminée, une manœuvre d’inversion sera
exécutée avec un temps fixe de 0,2s pour faciliter le déblocage manuel.
FONCTIONNEMENT DES ACCESSOIRES DE SECURITE
PHOTOCELLULE (COM-PHOT)
DIP 4 OFF => Si un obstacle est interposé entre les photocellules lorsque le portail est
fermé, celui-ci ne s’ouvre pas. Quand le portail est en fonctionnement, les
photocellules interviennent aussi bien pendant l’ouverture (avec reprise du
mouvement en ouverture qu’après de la libération des photocellules), que
pendant la fermeture (avec reprise du mouvement inverse qu’après de la
libération des photocellules).
DIP 4 ON => Si un obstacle est interposé entre les photocellules lorsque le portail
est fermé et que l’ouverture est actionnée, le portail s’ouvre (pendant
l’ouverture les photocellules n’interviendront pas). Elles n’interviendront
que pendant la phase de fermeture (avec rétablissement du mouvement
inverse après une seconde même si les photocellules sont encore
occupées).
GESTION FERMETURE IMMEDIATE APRES PASSAGE DEVANT LES PHOTOCELLULES
DIP 16 ON et DIP 4 OFF => C
omme le portail s’ouvre, en passant devant les photocellules,
le portail s’arrête. Terminé de transit, après 1 seconde, le portail
se ferme.
DIP 16 ON et DIP 4 ON => Comme le portail s’ouvre, en passant devant les photocellules,
le portail continue à s’ouvrir. Terminé de transit, le portail
s’arrête et après 1 seconde de pause il invertit le mouvement
en fermeture.
Si l’ouverture totale a lieu (fin du temps d’ouverture), la fermeture immédiate est
désactivée et le temps de fermeture automatique est activé (si le trimmer TCA est
activé et la DEL DL6 allumée).
S’il y a un passage rapide pendant la fermeture (par ex. un piéton) le portail se
ré-ouvrira pendant deux secondes pour se refermer ensuite.
DIP12 OFF => la fermeture immédiate après passage devant les photocellules est désactivée.
N. B. : Il est recommandé de contrôler le fonctionnement des photocellules au moins tous les
6 mois.
EDGE (BARRE PALPEUSE) (COM-EDGE)
Pendant l’ouverture, si elle est activée, elle change le mouvement en fermeture. Pendant la
fermeture, si elle est activée, elle change le mouvement en ouverture. Si elle reste occupée
après la première activation, elle effectue une nouvelle inversion après 2 secondes, pour
ensuite en faire une autre plus petite et donc signaler l’alarme de barre palpeuse en panne ou
occupée (contact NO).
Si la barre palpeuse reste occupée (contact NO), aucune manutention n’est permise.
Si vous n’en utilisez pas, ponter les bornes COM-EDGE.
MONITORAGE DES BARRES PALPEUSES DE SECURITE (A+TEST A-)
Grâce à l’entrée A+TEST et au DIP 12 en position ON, il est possible de contrôler la/les barre(s)
palpeuse(s).
Le monitorage est un Test de Fonctionnement de la barre palpeuse, exécuté à la fin de chaque
ouverture totale du portail.
Après chaque ouverture, la fermeture du portail n’est donc possible que si la/les barre(s)
palpeuse(s) ont passé le Test de Fonctionnement.
ATTENTION: LE MONITORAGE DE L’ENTREE BARRE PALPEUSE PEUT ETRE ACTIVE EN
METTANT LE DIP 12 SUR ON, OU BIEN DESACTIVE EN POSITIONNANT LE DIP 12 SUR OFF. EN
EFFET, LE TEST DE FONCTIONNEMENT N’EST POSSIBLE QUE DANS LE CAS OU IL S’AGIT DE
DISPOSITIFS DOTES DE LEUR PROPRE ALIMENTATION DE CONTROLE. UNE BARRE PALPEUSE
MECANIQUE NE PEUT ETRE MONITOREE, DONC LE DIP 12 DOIT ETRE POSITIONNE SUR OFF.
ALARME D’AUTOTEST BARRE PALPEUSE (DIP 12 ON)
A la fin de l’ouverture, si le monitorage de la barre palpeuse a un résultat négatif, une alarme,
signalée par le clignotant qui reste allumé, intervient. Dans cette situation, la fermeture du
portail n’est pas autorisée. Il n’est possible de rétablir le fonctionnement normal qu’en réparant
la barre palpeuse et en appuyant sur une des commandes habilitées.
BOUTON DE STOP (COM-STOP)
Durant n’importe quelle opération, le bouton de STOP arrête le portail.
S’il est enfoncé quand le portail est totalement ouvert (ou partiellement en utilisant la
commande piétonne), la fermeture automatique est exclue temporairement (si elle est habilitée
par le trimmer TCA et la DEL DL6 allumée). Il faut donc effectuer une nouvelle commande pour
le qu’il se referme.
Au cycle suivant, la fonction fermeture automatique sera réactivée (si habilitée par le trimmer
TCA et la LED DL6 allumée).
ALARME DU DETECTEUR DE COURANT
La centrale T2 24V est dotée de détecteurs automatiques qui changent le sens du portail en
cas d’impacts avec des choses ou des personnes en conformité avec les normes EN en vigueur
(toujours vérifier avec les outils appropriés le respect des valeurs imposées par la norme), sans
devoir effectuer des réglages particuliers sur la centrale, puisqu’ils sont gérés par un logiciel
interne propre.
Si après une première intervention du détecteur de courant en phase d’ouverture ou de
fermeture (seulement à grande vitesse), une seconde intervention a lieu, évidemment dans
le sens contraire, le portail s’arrête puis inverse son sens pendant 1 seconde. L’alarme sera
signalée par le clignotant qui restera actif durant une minute, pendant ce temps, il est possible
de rétablir le fonctionnement du portail en appuyant sur n’importe quel bouton de commande.
TRAVAIL AVEC HOMME PRESENT, DANS LE CAS DE PANNE DE SÉCURITÉ
Si le barre palpeuse est en panne ou engagé pour plus de 5 secondes, ou si la cellule
photoélectrique est en panne ou engagée pour plus de 60 secondes, les commandes
OUVERTURE, FERMETURE, K BOUTON et PIETONS fonctionnent seulement à homme present.
La signalisation de l’activation de cette opération est donnée par la LED de programmation
qui clignote.
Avec cette opération est autorisée l’ouverture ou fermeture seulement en appuyant sur les
boutons de contrôle. Le contrôle radio et la fermeture automatique sont exclues parce que leur
fonctionnement n’est pas autorisé par les règles.
A la restauration du contact de sécurité, l’opération automatique ou pas à pas est restaurée
après une seconde, et donc aussi la télécommande et la fermeture automatique sont de travail.
Note 1: Au cours de cette opération dans le cas de panne de les barres palpeuses (ou cellules
photoélectriques) les cellules photoélectriques (ou barres palpeuses) qui ne sont pas
en panne, fonctionnent encore avec l’interruption de l’opération en cours.
Note 2: Le bouton d’arrêt n’est pas considéré comme un contournement de la sécurité dans ce
mode, si il est pressé ou en panne, il ne permet pas de tout mouvement.
La manoeuvre à homme present est exclusivement une manoeuvre d’urgence
qui doit être effectuée pour des temps brefs et avec la sécurité de la vue quand
l’opérateur est en mouvement. Dès possible les protections en panne doivent être
rétablies pour un correct fonctionnement.
FEU CLIGNOTANT
N.B.: Ce tableau électronique peut alimenter QUELES FEUX CLIGNOTANTS AVEC CIRCUIT
CLIGNOTANT (ACG7061) avec ampoule de 24V et 20W maximum.
FONCTION PRE-CLIGNOTEMENT
DIP 5 - OFF => le moteur et le feu clignotant démarrent en même temps.
DIP 5 - ON => le feu clignotant démarre 3 secondes avant le moteur.
24
F
VOYANT DE SIGNALISATION PORTAIL OUVERT (COM-SIGNAL)
Il a pour tâche de signaler si le portail est ouvert, partiellement ouvert ou encore pas totalement
fermé. Il ne s’éteint que lorsque le portail est complètement fermé.
Pendant la programmation, cette signalisation est active.
N.B.: Maximum 3 W. Si la consommation des boîtiers de commande ou des ampoules dépasse
ce seuil, la logique du tableau électronique en sera compromise, engendrant un possible
blocage des opérations.
FONCTIONNEMENT APRES COUPURE DE COURANT (SANS PILES)
Au retour de la courant la led DL1 s’allume et reste allumée pendant tout le temps que le portail
reste ouvert. Elle s’éteindra à la complète fermetre du portail.
Il est conseillé d’ouvrir complètement le portail. Laissez le portail se fermer tout seul avec
la fermeture automatique ou attendez que le feu clignotant arrête de clignoter avant de
commander la fermeture.
Cette opération permettra au portail de se réaligner. En effet, si les moteurs se sont bloqués
et ont été déplacés de la position normale de fermeture pendant la coupure de courant, la
première manœuvre au retour de l’alimentation doit être complète.
Si le black-out se passe pendant le mouvement, ou avec le portail ouvert, et la première
commande est celle de fermeture, la fermeture se passera avec déphasage totale des portes
donc M2 se fermera avant et M1 se fermera après. Le mouvement separé des deux moteurs
évitera que les portes se touchent.
CARACTERISTIQUES TECNIQUES
- Intervalle de température
0 ÷ 55°C
< 95% sans condensation
- Humidité
- Tension d’alimentation 230V~ ± 10% (120V 60Hz sur
demande)
- Fréquence
50/60 Hz
- Alimentation batterie
20-24VCC
130VA
- Puissance du transformateur
primaire 230Vac
secondaire 18Vac
50 mA
- Consommation maximale
- micro-interrupteurs de réseau 100ms
- Puissance maximale voyant portail ouvert24Vdc 3W (équivalent à une petite
lampe de 3W ou à 5 DEL avec
résistance en série de 2,2 KΩ)
- Charge maximale feu clignotant
24Vdc 20W
- Courant disponible pour photocellules et accessoires 1A ±15%
200mA
- Courant disponible sur le connecteur radio
CARACTERISTIQUES TECHNIQUES RADIO (modèle T2 24V crx)
- Fréquence réception 433,92MHz
- Impédance
52Ω
>2,24µV
- Sensibilité
- Temps d’excitation
>2,24µV
- Temps de désexcitation
300ms
- Toutes les entrées doivent être utilisées avec des contacts propres car l’alimentation est
générée à l’intérieur de la carte (tension sûre) pour garantir le respect de la double isolation
et de l’isolation renforcée par rapport aux parties sous tension dangereuse.
- Les éventuelles connexions de circuits externes aux sorties du tableau électronique doivent
être faites pour garantir la double isolation ou l’isolation renforcée par rapport aux parties
sous tension dangereuse.
- Toutes les entrées sont gérées par un circuit programmé intégré qui exécute un autocontrôle
à chaque mise en route.
SOLUTION DES PROBLEMES
Après avoir effectué tous les raccordements en suivant attentivement le schéma et avoir
positionné le portail en position intermédiaire, vérifier l’allumage correct des leds rouges DL7,
DL8 et DL9.
Si les leds ne s’allument pas, en maintenant toujours le portail en position intermédiaire, vérifier
les points ci-après et éventuellement remplacer les composants qui ne fonctionnent pas.
DL7 éteinte Photocellules en panne
DL8éteinte
Bande de contact de sécurité en panne (Si la bande de contact n’est pas
reliée, effectuer la connexion entre COM et EDGE)
DL9 éteinte
Bouton de STOP en panne (Dans le cas où le STOP n’est pas connecté,
ponter entre COM et STOP).
Durant le fonctionnement avec opérateur présent, avec DIP n° 1 sur ON, vérifier que durant
l’ouverture de M1 et M2, les leds vertes DL2 et DL4 s’allument, et que durant la fermeture de
M1 et M2, les leds rouges DL3 et DL5 s’allument.
Dans le cas contraire, intervertir les fils du moteur en question.
DEFAUT
SOLUTION
Après avoir effectué les différents raccordements et avoir allumé le courant,
toutes les leds sont éteintes.
Vérifier l’intégrité des fusibles F1, FUSE 1.
En cas de fusible hors service, ne remplacer qu’avec des fusibles de valeur adéquate
F1 T 2AFUSIBLE DE PROTECTION TRANSFORMATEUR (extérieur à la carte T2 24V)
FUSE 1 8A FUSIBLE DE PROTECTION MOTEURS
Le moteur ouvre et ferme, mais n’a pas de force et se déplace lentement.
Vérifier le réglage des trimmers RUN et LOW-SPEED.
Le portail effectue l’ouverture, mais ne se referme pas après le temps
configuré.
S’assurer que le trimmer TCA est habilité avec la DEL DL6 allumée.
Si le bouton OPEN est toujours enfoncé, remplacer le bouton ou le boîtier de commande OPEN. Si l’autotest
de la barre palpeuse est négatif, vérifier les connexions entre le tableau électronique et l’alimentation de la/
des barre(s) palpeuse(s). Attention: Si vous n’utilisez pas un boîtier d’alimentation pour la barre palpeuse, le
DIP 12 doit être positionné sur OFF.
Le portail ne s’ouvre pas et ne se referme pas en actionnant les différents Contact bande de contact de sécurité en panne. Contact photocellules en panne avec DIP 4 OFF. Replacer
boutons K, Radio, Open et Close.
ou remplacer le contact correspondant.
La serrure électrique ne fonctionne pas.
S’assurer d’avoir activé le DIP 8 sur ON.
La DEL DL1 clignote rapidement et aucune manutention n’est habilitée.
Positionner les DIP switch 1, 2 ou 3 sur OFF.
25
F
OPTIONS
Pour les branchements et les données techniques des accessoires, se conformer aux livrets d’instruction correspondants.
BRAS LONG
COFFRE-FORT STONE
BRAS LONG pour portails avec l’axe des gonds positionné jusqu’à 50 cm du bord du
poteau
code ACG8034
Coffret de sécurité empêchant tout accès non autorisé aux dispositifs de commande.
Fourni de série, il est équipé d’un poussoir à bascule (ouverture-fermeture), ainsi que d’un
dispositif de déblocage de l’électro-frein. A besoin du câble ACG8022.
En aluminium moulé sous pression - IP54
code ACJ9078
COFFRE-FORT FLAT
CÂBLE POUR DÉBLOCAGE
Coffret de sécurité empêchant tout accès non autorisé aux dispositifs de commande.
Fourni de série, il est équipé d’un poussoir à bascule (ouverture-fermeture), ainsi que d’un
dispositif de déblocage de l’électro-frein. A besoin du câble ACG8022.
En aluminium moulé sous pression - IP54
code ACJ9071
Câble pour déblocage de l’extérieur à connecter au coffre-fort.
code ACG8022
SERRURE ELECTRIQUE
Serrure Horizontale - droite vue externe - 12Vac
Serrure Horizontale - gauche vue externe - 12Vac
Serrure Verticale - 12Vac
BATTERIE
code ACG8660
code ACG8670
code ACG8650
Batterie 2,2Ah 12V
code ACG9515
T2 24V Wi-Fi
Tableau avec détecteurs d’impacts et carte MASTER Wi-Fi.
Avec boîtier.
code ABT2025W
26
FICHE DE CHARGE BATTERIE
code ACG4661
G
B
SYSTEM LAY-OUT
2
7
3
TECHNICAL FEATURES
PREMIER 24V is an irreversible actuator designed for swing gates long up to
3 m (Pic. 1).
PREMIER 24V works without electric limit switches, but with mechanical
stoppers.
A few seconds after that the gate leaf reaches the end of the stoke, either a time
or a current sensor device, will cut out the motor (power supply).
4
TECHNICAL
DATA
5
1
6
1
5
4
PREMIER 24V
Max. gate leaf length
m
3
Max. gate leaf weight
kg
300
Average opening time
s.
17
Maximum thrust torque
Nm
1
1 - PREMIER 24V operator
2 - Tuned aerial
3 - Flashing lamp
4 - Key selector
5 - Photoelectric cells (external)
6 - Safety lock
7 - Electrical lock
150
230V~ 50Hz
EEC Power supply
Motor capacity
W
Power absorbed
A
0,311
Normative cycles
n°
∞ - 17s/2s
Daily operations suggested
n°
Service
72
60
80%
Guaranteed consecutive cycles
n°
60/17s
Weight of electroreducer
kg
7,5
Noise
db
<70
Volume
m3
0,0184
Operating temperature
°C
-30 ÷ +55°C
Protection grade
IP
44
Measurements in mm / inch
27
G
B
INSTALLATION PREMIER
PRE-INSTALLATION CHECK LIST
The gate leaves must be firmly fixed to the hinges on the gate pillars, they must not flex during
the movement and they must swing without any friction.
Before installing the operator, make sure you have enough room to fix the operator on the pillar.
In case the gate is like the one depicted in Pic. 1, there is no need for any modification.
Gate features and installation must comply with local regulations and standards.
The gate can be automated only if it is in good conditions and complies with EN12604 norms.
- The gate leaf must not have a pedestrian door in its structure. Should there be a pedestrian
opening, take the appropriate steps according to EN12435 norms (e.g. cutting out the motor
when the pedestrian door is opened by fixing a safety micro switch connected to the control
board).
- Make sure not to create any trapping points or areas (e.g. when the gate completely opened,
between any opening in the gate frame and the side wall).
Parts to install meeting the EN 12453 standard
USE OF THE SHUTTER
Skilled persons
(out of public
area*)
Skilled persons
(public area)
Unrestricted
use
A
B
non possibile
with visible impulses
(e.g. sensor)
C or E
C or E
C and D, or E
with not visible impulses
(e.g. remote control device)
C or E
C and D, or E
C and D, or E
C and D, or E
C and D, or E
C and D, or E
COMMAND TYPE
with manned operation
automatic
EMERGENCY MANUAL RELEASE
This applies only if the unit is not equipped with back-up batteries. In case of a black-out, the
gate can be pulled open after the operator has been unlocked with the emergency key provided
(rotate the key clockwise by 180°, Pic. 2).
EMERGENCY MANUAL RELEASE THROUGH AN EXTERNAL STRONG
BOX
* a typical example are those shutters which do not have access to any public way
A: Command button with manned operation (that is, operating as long as activated),
like code ACG2013
B: Key selector with manned operation, like code ACG1010
C: Adjustable power of the motor
D: Safety strips and/or other safety devices to keep thrust force within the limits of
EN12453 regulation - Appendix A.
E: Photocells, like code ACG8026 (To apply every 60÷70cm for all the height of the
column of the gate up to a maximum of 2,5m - EN 12445 point 7.3.2.1)
In case of a black-out, should you need to unlock the gate from outside through an external
Strong Box, secure one end of the steel cord with sheath (A) (code ACG8022) to the unlocking
lever (B) on the operator, and the other end to the unlocking device (C) inside the strong box,
as in Pic. 3 (code ACJ9071 or ACJ9078).
CAUTION
In order to manually open the gate leaf make sure of the following:
- The gate leaves must be endowed with appropriate handles;
- Position of the handles onto the gate leaves must be in risk free area;
- The manual force necessary to move the gate leaves should not be higher than 225 N, in case
of installations at domestic/private dwellings, and 390N in case of installations in business
premises (according to points 5.3.5 of the EN12453 norm).
Note: in case of an installation with an overlapping two leave swing gate, to ensure a safe/
proper locking, a mechanical bolt must be installed along with an electric lock. The mechanical
bolt (ACG5000) must be installed at the bottom of the first gate leaf to close so that it will be
triggert by the pressure of the second gate leaf. The electric lock will latch one gate leaf to
the other.
2
C
B
B
A
3
28
G
B
FIXING THE OPERATOR TO THE PILLAR (D)
In order to carry out a proper installation of the operator, it is necessary to comply with the geometry measurement shown in the tables in Pic. 6 and 8.
X
138
80
80
98
13
D
4
ASSEMBLING DRIVE ARM WITH THE ANTI-THEFT
LOCKING DEVICE (E)
Assemble the arms as shown in Pic. 5.
Caution: Once the screws V and W have been thoroughly tightened (Pic.
5) unscrew them for half a turn, in order to guarantee a free movement
of the arm.
After assembling the arm, unlock the motor and fix the arm to the motor
with the supplied screw and M10 washer.
V
DRL8x17I
W
DRL10x20I
DRG6I
E
DRL8x17I
DRL8x17I
With the gate in closing position and the motor at rest, the anti-theft lock
(E) keeps the gate leaves securely closed and prevents anybody from
forcing the gate leaves open.
5
FIXING THE DRIVE ARM WITH THE ANTI-THEFT LOCKING DEVICE (E)
Unlock the operator.
Caution: start the operation with the gate in closing position. Straighten the levers until the anti-theft lock (E Pic. 5) is engaged and stressed. Move the levers back a little bit just enough to
avoid keeping the anti-theft locking in working position (stressed) every time the gate will close.
α°
90
90
90
A max A max*
140
200
205
190
200
205
90
225
225
95
0
0
90
100
105
110
-
0
0
0
240
0
0
0
X
60
70
80
B
130
140
150
I
T sec
270
19
300
20
230
18
0
15
302
19
322
19
90
160
135
16
70
140
284
18
315
19
110
90
110
155
180
160
180
225
B
A
X
α
I
6
A max* - In case only one mechanical stopper is used in opening (Pic. 8)
29
G
B
Should the drive arm be replaced, use a M14X20 or longer as extractor
of the arm from the PREMIER 24V shaft. Just screw it in.
7
ADJUSTMENT OF THE MECHANICAL STOPPERS
Adjust the mechanical stoppers as shown in Pic. 8.
When the gate is completely closed, slide the close mechanical stopper (F) against the arm.
Then tighten it (key n. 5) with the two Allen screws 6x20 provided. In case an electric lock is
fitted on the gate, the close mechanical stopper must be removed.
To adjust opening position, slide the open mechanical stopper (G) against the arm (gate must
be opened completely) and tighten it as described above.
Caution: Always use two Allen screws for every stopper.
Caution: The drive arm is equipped with an anti-theft locking device (E in Pic. 5). If the close
mechanical stopper is not properly adjusted the anti-theft device can get damaged
in a short period.
G
MAINTENANCE
Maintenance should be carried out by skilled and qualified staff only, after switching off the
mains supply.
Regularly lubricate the hinges of the gate every 6 months and keep the force monitored
(according to EN12453).
F
8
30
T2 24V
T2 24V CRX
ELECTRIC CONNECTIONS
code AC07088
code AC07089
24Vdc 0,8A ± 15% for ACCESSORY SUPPLY
24Vdc 0,8A ± 15% for AUTOTEST SAFETY STRIPS
PEDESTRIAN
STEP BY STEP
ELECTRIC
LOCK
PHOTOCELLS
COMMON
SAFETY STRIPS
LED
BLINKER
24Vdc 20W
R=2,2K 1/4W
POWER SUPPLY
230Vac 50 Hz
FUSE
T2A
TRANSFORMER
COMMON
CLOSE
OPEN
STOP
ANTENNA
ANTENNA
BRAIDING
M1
M2
31
G
B
G
B
A - CONTROL PANEL FEATURES
J1
NF
Power supply 230 Vac 50/60 Hz - external to the control
panel - (120V/60Hz upon request)
J2
COM.
Common contact
CLOSE
Closing impulse contact (NA)
OPEN
Opening impulse contact (NA)
STOP
STOP impulse contact (NC)
AERIAL
Radio Antenna
SIGNAL
Gate open state and battery state output indicator (24Vdc 3W
max)
A+TEST
+ 24Vdc safety strip self-test power supply
J3
EDGE N.C.
Safety strip contact (NC)
COM.
Common contact
PHOTO N.C.
Photocells contact (NC)
K BUTT.
Single pulse contact (NO)
PED. BUTT.
Pedestrian opening contact (NA)
A+
+ 24Vdc accessories power supply
A-
- 24Vdc accessories power supply
LOCK
Electric lock connection (MAX 15W 12V)
J1
J2
F1
J3
TRANSFORMER
J4
FUSE 1
J9
J10
J5
- 24Vdc blinker (code ACG7061) power supply. Pay attention
to the polarity.
J4
SECONDARY
TRANSFORMER
Connection to secondary coil of transformer 18 Vac
J5
MOTOR 1
MOTOR 1 CONNECTION (without polarity)
J6
MOTOR 2
MOTOR 2 CONNECTION (without polarity)
SW T2 24V
Connector dedicated to the factory programming. DO NOT
REMOVE ANY JUMPER! OTHERWISE THE OPERATOR WILL
NOT WORK!
SW RADIO
Connector dedicated to the factory programming (only CRX
control board) DO NOT REMOVE ANY JUMPER! OTHERWISE
THE OPERATOR WILL NOT WORK!
J7
J8
J7
RADIO
Built-in radio module (model CRX), or connector for radio
receiver RIB, 24 Vdc supply
J10
BATTERY
CHARGER
Connector for charge card of 24Vdc battery (code ACG4648)
TR1
TRIMMER RUN
Trimmer for high speed adjustment operations
TR2
TRIMMER LOW
SPEED
Trimmer for low speed adjustment operations
TRIMMER TCA
B - SETTINGS
TR3
S3
J9
TR3
J6
J8
TR1
Trimmer for automatic closing time adjustment (DISABLED
DEFAULT AND DL6 LED OFF)
DIP 1 (ON) - MOTOR ROTATION DIRECTION CONTROL (POINT C)
DIP 2 (ON) - TIMER (POINT D)
DIP 3 ( ON) - ACTIVATES DOOR RELEASE DURING PHASES OF SLOWDOWN AND
TOTAL OPENING AND CLOSING (AS PER THE IMPACT TESTS OF EN12453)
DIP 1-2MEMORIZATION/CANCELLATION OF RADIO CONTROL CODES FOR TOTAL
OPENING (ONLY MODEL CRX) (POINT E)
DIP 1-3MEMORIZATION/CANCELLATION OF RADIO CONTROL CODES FOR
PEDESTRIAN OPENING (ONLY MODEL CRX) (POINT F)
DIP 2-1MICRO-SWITCH CONTROLLER FOR PEDESTRIAN OPENING TIMER
DIP 4Photocells always active (OFF) - Photocells active only during closing (ON)
DIP 5 Pre-blinking (ON) - Normal blinking (OFF)
DIP 6Single pulse command (K BUTT) and step-by-step radio receiver (OFF) - automatic
(ON)
DIP 7Power sensor operation (ON-activated) time operation (OFF-activated).
DIP 8 Electric lock activation (ON-activated)
DIP 9 Electric lock pulse release (ON-activated)
DIP 10 Electric lock pulse engagement (ON-activated)
DIP 11 Easy release activation (ON-activated)
DIP 12 Sensor TEST activation (ON-activated).
DIP 13 Selection of 1 or 2 motor operation (default OFF 2 motors)
DIP 14 OFFPREMIER 24V WITH ELECTRIC LOCK
ON PREMIER 24V WITHOUT ELECTRIC LOCK
DIP 15 ON
DIP 16 IMMEDIATE CLOSING AFTER PASSING IN FRONT OF PHOTOCELLS
ONACTIVATED
OFFDEACTIVATED
S3
PROG
Programming button
FUSE 1
T8A
Motor protection fuse
F1
T2A
Transformer protection fuse
TR2
JP1 =>Check that the jumper is inserted!
JP2 =>Check that the jumper is inserted!
JP3 =>Check that the jumper is inserted!
PROG =>
S3 Programming button
ADJUSTMENTS
ATTENTION: PUT DIP 3 IN THE ON MODE ONLY AFTER HAVING CARRIED OUT ALL
THE PROGRAMMING PROCEDURES.
NOTE: WITH DIP 3 (ON) BRIEF GATE REVERSAL AFTER IMPACT IS ACTIVATED.
THIS BRIEF GATE REVERSAL PERMITS STATIC FORCE TO BE REDUCED TO ZERO
WITHIN 5 SECONDS AS PER STANDARD EN12453 POINT A.2.2 (ACCEPTABLE
STATIC FORCE), THEREBY COMPLYING WITH THE IMPACT TESTS ALSO OUTLINED
BY EN12453). IF COMPLIANCE WITH THE AFOREMENTIONED STANDARD IS
UNNECESSARY, SIMPLY POSITION DIP 3 TO OFF. IN THIS CASE THE GATES STOP
WITHOUT REVERSING.
RUN TRIMMER (TR1) high-speed electronic regulator
This trimmer permits motor speed adjustment (the default setting is maximum speed).
Adjustment of the automation is useful for compliance with European impact standards.
LOW-SPEED TRIMMER (TR2) Electronic slow speed approach control
The slow speed control is performed by adjusting the LOW- SPEED TRIMMER which changes
the voltage output across the motor(s) (turning it clockwise increases the speed). Adjustment
is performed to determine the correct speed at the end of opening and closing according to
the gate or when there is friction that might cause the system to function poorly.
AUTOMATIC CLOSING TRIMMER - TCA (TR3) TOTAL OR PEDESTRIAN default NOT
32
G
B
ACTIVATED and LED DL6 OFF (TRIMMER FULLY ROTATED COUNTERCLOCKWISE)
This trimmer makes it possible to adjust the time for total or pedestrian automatic closing.
Only with gate completely (total) or partially (pedestrian) open and LED DL6 on (trimmer
rotated clockwise).
The pause time can be adjusted from a minimum of two seconds up to a maximum of two
minutes.
LED SIGNALS
DL1 program activated (red)
DL2 gate opening M2 (green)
DL3 gate closing M2 (red)
DL4 gate opening M1 (green)
DL5 gate closing M1 (red)
DL6 automatic closing indicator (red)
DL7 photocell contact (NC) (red)
DL8 sensor contact (NC) (red)
DL9 STOP button (NC) (red)
DL10radio code program (green)
FUSES
Fuse 1 T 8A
MOTOR PROTECTION FUSE
F1 T 2ATRANSFORMER PROTECTION FUSE (on the outside of the T2 24V board)
1 - Set DIP 1 to ON => LED DL1 starts flashing.
2 - Press and hold the PROG button. (movement is now manually controlled - open-stopclose-stop-open - etc.) => GREEN LEDS DL2 and DL4 are lit and the gate panels open
with a fixed lag of 2 sec. If they close instead of open, release the button and reverse
the two wires on the motor used.
3 - After opening release the PROG button and calibrate the mechanical opening stops (on
the operator).
4 - Press and hold the PROG button => RED LEDs DL3 and DL5 turn on and the gate panels
close with a time lag of 2 sec.
5 - Continue to hold the PROG button until the gate is completely closed.
6 - Leave the two doors completely closed to set the timer.
7 - Reset DIP1 to OFF => LED DL1 turns off, signaling exit from control.
N.B.: During this check the stop, the photocells and the sensors are not active.
D - SETTING THE TIMER FOR 2 MOTORS (#)
WITH POWER SENSOR ACTIVATED (DIP 7 ON)
WHILE SETTING THE TIMER THE POWER SENSOR IS CONTINUOUSLY ACTIVATED.
1 - The gate must be completely closed.
2 - Set DIP 2 to ON => LED DL1 will blink rapidly.
3 - Press the PROG button. => M1 opens.
4 - When the mechanical opening stop is reached, the AUTOMATIC POWER SENSOR stops
M1 (memorizing the time and the power) => At the same time M2 is triggered to open.
5 - When the mechanical opening stop is reached, the AUTOMATIC POWER SENSOR stops
M2 (memorizing the time and the power).
6 - Press the PROG button. => M2 closes.
7 - Press the PROG button. => M1 closes and sets the lag time between M2 and M1. At
the same time LED DL1 stops flashing indicating exit from the programming procedure.
Safety and other gate commands now operate normally (inversions, stop, alarms, etc.).
8 - The gate panels will close in high-speed mode (depending on how you set the RUN
trimmer) and near total closure in the slow mode (depending on how you set the LOWSPEED trimmer).
9 - Upon closing the power sensors stop the gate.
10 - AFTER PROGRAMMING RESET DIP 2 TO OFF.
CAUTION: FOR ONE MOTOR CONTROL DIP 13 MUST BE POSITIONED TO ON; DURING
PROGRAMMING THE POWER SENSOR IS CONTINUOUSLY ACTIVE.
The gate must be completely closed.
1 - Set DIP 2 to ON => LED DL1 will blink rapidly.
2 - Press the PROG button. => M1 opens.
When the mechanical opening stop is reached, the AUTOMATIC POWER SENSOR stops
M1 (memorizing the time and the power).
3 - Press the PROG button. => M1 closes.
At the same time LED DL1 stops flashing indicating exit from programming. Safety and
other gate commands now operate normally (inversions, stop, alarms, etc.).
Upon closing the power sensor stops the gate.
4 - AFTER PROGRAMMING RESET DIP 2 TO OFF.
(#) DURING PROGRAMMING THE SAFETY DEVICES ARE ACTIVE AND STOP THE
PROGRAMMING PROCEDURE (LED DL1 FROM FLASHING BECOMES CONSTANT).
TO REPEAT PROGRAMMING SET DIP 2 TO OFF, CLOSE THE GATE USING THE
PROCEDURE “MOTOR ROTATIONAL DIRECTION CONTROL” AND REPEAT THE
DESIRED PROGRAMMING PROCEDURE.
D - SETTING THE TIME FOR 2 MOTORS (#)
1 - The gate must be completely closed.
2 - Set DIP 2 to ON => LED DL1 will blink rapidly.
3 - Press the PROG button. => M1 opens.
4 - When the mechanical opening stop is reached, wait a second then press the PROG
button => M1 stops and M2 opens.
5 - When the mechanical opening stop is reached => wait 1 second and press the PROG
button => M2 stops.
6 - Press the PROG button => M2 closes.
7 - Press the PROG button => M1 closes setting the time lag between M2 and M1.
At the same time LED DL1 stops flashing indicating exit from the programming
procedure.
Safety and other gate commands now operate normally (inversions, stop, alarms, etc.).
8 - After the set amount of time, the gate will stop.
9 - AT THE END OF PROGRAMMING RESET DIP 2 TO OFF.
NOTE: The slowdown is automatically determined by the control board during the time
setting phase and is activated at about 50 to 60 cm before reaching the mechanical opening
or closing limit.
D - SETTING THE TIME FOR 1 MOTOR (#)
WITH TIME OPERATION (DIP 7 OFF)
C - MOTOR ROTATIONAL DIRECTION CONTROL
D - SETTING THE TIME FOR ONE MOTOR (M1) (#)
WITH POWER SENSOR ACTIVATED (DIP 7 ON)
WITH TIME OPERATION (DIP 7 OFF)
CAUTION: FOR ONE MOTOR CONTROL DIP 13 MUST SET TO ON
1 - The gate must be completely closed.
2 - Set micro-switch DIP 2 to ON => LED DL1 will blink rapidly.
3 - Press the PROG button => M1 opens.
4 - When the mechanical opening stop is reached, wait a second then press the PROG
button => M1 stops.
5 - Press the PROG button => M1 closes.
At the same time LED DL1 stops flashing indicating exit from the programming
procedure.
Safety and other gate commands now operate normally (inversions, stop, alarms, etc.).
6 - After the set amount of time, the gate will stop.
7 - AT THE END OF PROGRAMMING RESET DIP 2 TO OFF.
D - SETTING PEDESTRIAN OPENING TIMES (#) BOTH FOR TIME AND POWER
SENSOR OPERATION
With gate closed:
1 - First set DIP2 to ON (LED DL1 flashes quickly) and then DIP1 to ON ( LED DL1 flashes
slowly).
2 - Push the pedestrian button (COM-PED.BUTT) => M1 opens.
3 - Push the pedestrian button to stop movement (thereby setting M1 opening).
4 - Push the pedestrian button to start closing.
5 - Upon closing reset DIP 1 and 2 to OFF.
(#) DURING PROGRAMMING THE SAFETY DEVICES ARE ACTIVE AND STOP THE
PROGRAMMING PROCEDURE (LED DL1 FROM FLASHING BECOMES CONSTANT).
TO REPEAT PROGRAMMING SET DIP 2 TO OFF, CLOSE THE GATE USING THE
PROCEDURE “MOTOR ROTATIONAL DIRECTION CONTROL” AND REPEAT THE
DESIRED PROGRAMMING PROCEDURE.
E - RADIO CODE PROGRAMMING FOR TOTAL OPENING
(UP TO 62 CODES - CRX MODELS ONLY)
Programming can be done only when the gate is stationary.
1 - First set DIP 1 to ON and then DIP 2 to ON.
2 - The red LED DL1 flashes ON every 1 sec. and OFF for 10 seconds.
3 - Press the remote control button (usually channel A) within the allotted 10 seconds. If the
remote is memorized properly LED DL10 (green) blinks.
4 - The programming time for codes is automatically renewed in order to memorize the
next remote control.
5 - To finish programming, wait 10 seconds, or press the PROG button briefly. The red LED
DL1 stops flashing.
6 - Reset DIP 1 to OFF and DIP 2 to OFF.
7 - End of procedure.
CANCELLATION OF ALL RADIO CODES FOR TOTAL OPENING
Cancellations can only be performed when gate is stationary.
1 - Set DIP 1 to ON and then DIP 2 to ON.
2 - The red LED DL1 flashes ON every 1 second and OFF for 10 seconds.
3 - Press and hold the PROG button for 5 seconds. Memory cancellation is indicated by two
flashes of green LED DL10.
4 - The red LED DL1 remains active and you can add new codes as shown above.
5 - Reset DIP 1 to OFF and DIP 2 to OFF.
6 - End of procedure.
INDICATOR MEMORY FULL OF RADIO CODES FOR TOTAL OPENING
Indication only when gate is stationary.
1 - Set DIP 1 to ON and then DIP 2 to ON.
2 - The green LED DL10 flashes 6 times when the memory is full (62 codes).
3 - LED DL1 will then remain active for 10 seconds enabling possible cancellation of codes.
4 - Reset DIP 1 to OFF and DIP 2 to OFF.
5 - End of procedure.
33
G
B
gate reopens.
F - PROGRAMMING PEDESTRIAN OPENING RADIO CODES
(UP TO 62 CODES - CRX MODELS ONLY)
Programming can be done only when the gate is stationary.
1 - Set DIP 1 to ON and then DIP 3 to ON.
2 - The red led DL1 flashes ON for 1 second and OFF for 1 second for 10 seconds.
3 - Press the remote control button (usually channel B) within the allotted 10 seconds. If the
remote is properly memorized LED DL10 (green) blinks.
4 - The programming time for codes is automatically renewed in order to memorize the
next remote control.
5 - To finish programming wait 10 seconds, or press the PROG button briefly. The red LED
DL1 stops flashing.
6 - Reset DIP 1 to OFF and DIP 3 to OFF.
NOTE: If LED DL1 CONTINUES BLINKING QUICKLY IT MEANS THAT DIP 1 IS STILL
SET TO ON AND THAT ANY OPERATION IS REFUSED.
7 - End of procedure.
CANCELLATION PROCEDURE FOR ALL PEDESTRIAN OPENING RADIO CODES
Cancellation can only be performed when the gate is stationary.
1 - Set DIP 1 to ON and then DIP 3 to ON.
2 - The red LED DL1 flashes ON for 1 second and OFF for 1 second for 10 seconds.
3 - Press and hold the PROG button for 5 seconds. Memory cancellation is indicated by two
flashes of green LED DL10.
4 - The red LED DL1 remains active and you can add new codes as shown above.
5 - Reset DIP 1 to OFF and DIP 3 to OFF.
6 - End of procedure.
INDICATION MEMORY FULL OF PEDESTRIAN OPENING RADIO CODES
Indication only when the gate is stationary.
1 - Set DIP 1 to ON and then DIP 3 to ON.
2 - The green LED DL10 flashes 6 times when the memory is full (62 codes).
3 - The LED DL1 will then remain active for 10 seconds enabling possible cancellation of
codes.
4 - Set DIP 1 to OFF and DIP 3 to OFF.
5 - End of procedure.
CONTROL ACCESSORIES OPERATION
ATTENTION: ONLY IMPULSIVE COMMANDS HAVE TO BE CONNECTED.
Make sure that any other type of command accessories (e.g. mass detectors)
used on the installation are set in the IMPULSIVE mode, otherwise, the gate will
be operated even without the protection of the safety devices.
STEP-BY-STEP BUTTON (COM-K BUTTON)
DIP 6 OFF =>It cyclically performs the commands open-stop-close-stop-open etc.
DIP 6 ON =>Opens the gate when closed. There is no effect if activated while opening. If
activated when gate is open, the gate closes. If activated while closing, the
gate reopens.
OPEN BUTTON (COM-OPEN)
The button controls the opening movement when the gate is stationary. If activated while
closing, it reopens the gate.
CLOCK FUNCTION OF OPEN BUTTON
If you wish to use a TIMER (or simply a switch) to open and hold the gate
opened, you must request a T2 24V with firmware version fw 03 NOUP. If
the version is fw 03 or higher, BEWARE: IN CASE OF FAILURE OF THE SAFETY
DEVICES, A MINUTE AFTER THE TIMER OR THE SWITCH HAVE BEEN ACTIVATED,
THE GATE WILL OPEN WITHOUT ANY SAFETY PROTECTION!
This function is useful during peak hours, when vehicle traffic is slow (e.g. entry/exit
of workers, emergencies in parking or residential areas and, temporarily, for moving
operations).
CLOCK FUNCTION APPLICATION
It is necessary to request a T2 24V control panel with firmware 02. By connecting a
switch and/or a daily/weekly clock (instead of or in parallel to the open button N.O. “COMOPEN”), you can open and keep the automation open for as long as the switch is pressed
or the clock remains active. Command functions are inoperative with open automation.
Releasing the switch or at the preset time, the automation closes immediately.
CLOSE BUTTON (COM-CLOSE)
Controls the closing movement when the gate is stationary.
REMOTE CONTROL
DIP 6 OFF =>It cyclically performs the commands open-stop-close-stop-open etc.
DIP 6 ON => Opens the gate when closed. There is no effect if activated while opening. If
activated when gate is open, the gate closes. If activated while closing, the
PEDESTRIAN OPEN BUTTON (COM-PED.BUTT.)
Partial opening and closing control. During pedestrian opening, pausing or closing, you can
control the opening of any command linked to the T2 24V board. With DIP 6 you can choose
the operation mode of the pedestrian push button.
DIP 6 OFF =>It cyclically performs the commands open-stop-close-stop-open etc.
DIP 6 ON =>Opens the gate when closed. There is no effect if activated while opening. If
activated when gate is open, the gate closes. If activated while closing, the
gate reopens.
ELECTRIC LOCK (LOCK)
Set DIP 8 to ON to enable control of the electric lock when opening.
ELECTRIC LOCK PULSE RELEASE IN OPENING
Set DIP 9 to ON to enable the electric lock pulse release when opening (provided DIP 8 is
ON).
If a command to open the gate is given when the gate is closed, the closing movement is
performed for 0.5 seconds and the electric lock is simultaneously activated (followed by a
0.5 second pause and then the opening of the gate).
ELECTRIC LOCK PULSE ENGAGEMENT
Set DIP 10 to ON to enable the pulse engagement of the electric lock when closing. Upon
closing, motors are activated for 0.5 seconds at full voltage to ensure lock engagement.
EASY MOTOR RELEASE
Set DIP 11 to ON to enable easy manual release (provided that DIP 10 is ON), upon closing a
reverse motion with a fixed time of 0.2 seconds occurs to facilitate manual release.
OPERATION OF SAFETY ACCESSORIES
PHOTOCELL (COM-PHOT)
DIP 4 OFF =>if an obstacle is placed in range of the photocells when the gate is closed,
the gate does not open. During operation, photocells work when opening
(by starting the opening movement only after the obstacle is removed)
and closing (by starting the reverse movement only after the obstacle is
removed).
DIP 4 ON => if an obstacle is placed in range of the photocells when the gate is closed
and the command to open is given, the gate opens (the photocells do not
work while opening). Photocells work only during closing (with reverse motion
restored after a second, even if they are still engaged).
CONTROL OF IMMEDIATE CLOSING AFTER MOVEMENT IN FRONT OF PHOTOCELLS
DIP 16 ON and DIP 4 OFF =>if photocells are engaged during opening, the gate stops
and the gate only closes one second after the photocells
are disengaged.
DIP 16 ON and DIP 4 ON => if photocells are engaged during opening, the gate continues
to open. Upon disengagement of the photocells, the gate
stops and reverses closing motion after a one second pause.
If total opening is reached (end of opening time), immediate closing is deactivated
and automatic time closing is activated (if TCA trimmer is activated and LED DL6
is on). If during closing there is a rapid movement (e.g. pedestrian) the gate will
open again for two seconds and then close once again.
DIP 12 OFF => immediate closing after movement in front of the photocells is deactivated.
N.B.: Please check photocell operation at least every six months.
EDGE (SAFETY STRIP) (COM-EDGE)
If engaged during opening, reverses the motion when closing.
If engaged when closing, reverses the motion when opening.
If it remains engaged again, it performs a further reversal after 2 seconds, then performs an
additional short reversal and then gives the sensor failure or engaged alarm (N.O. contact).
If the sensor remains engaged (N.O. contact) no movement is allowed.
If not used, jump the terminals COM-EDGE.
MONITORING OF SAFETY SENSORS (A+ TEST A-)
Sensors can be monitored through the A+ TEST input and DIP 12 ON.
The monitoring consists of a functional test of the sensor run after every full gate opening.
Closing the gate is therefore permitted only if the sensors have passed the functional test
after each opening.
CAUTION: MONITORING OF THE SENSOR INPUT CAN BE ACTIVATED WITH DIP 12 ON OR
DEACTIVATED WITH DIP 12 OFF. IN FACT, THE FUNCTIONAL TESTING OF SENSORS IS
‘POSSIBLE ONLY IF THESE DEVICES HAVE THEIR OWN POWER SUPPLY.
A MECHANICAL SENSOR CAN NOT BE MONITORED, SO DIP 12 SHOULD BE SET TO OFF.
SENSOR AUTOTEST ALARM (DIP 12 ON)
If the sensor fails the monitoring test after opening, an alarm is displayed by the blinker
lighting up. Gate closure is not allowed in this condition. Normal operation can be restored
only by repairing the sensor and pressing one of the activated controls.
34
G
B
STOP BUTTON (COM-STOP)
The STOP button stops the gate during any operation.
If held when the gate is fully open (or partially when using the pedestrian control) automatic
closing is temporarily deactivated (if activated by the TCA trimmer and LED DL6 on). It is
therefore necessary to use a new command to make it close.
The automatic closing function is reactivated on the next cycle (if activated by the TCA
trimmer and LED DL6 on).
POWER SENSOR ALARM
The T2 24V control panel has automatic sensors that make the movement of the gate
reverse in case of impact against objects or persons in accordance with the current EN
standards (always use the right tool to ensure compliance with the values imposed by the
standard), without special adjustments on the control panel, as it operates using special
internal software. If the power sensor is used in opening or closing (only in high-speed) and
then again, in the opposite direction, the gate stops and then reverses for 1 second.
The alarm status will be displayed by the blinker which will remain active for one minute,
during which time you can restore gate operation by pressing any command button.
FUNCTIONING IN DEAD MAN MODE WHEN THE SAFETY DEVICES ARE FAILING
If the safety edge fails or remains engaged for more than 5 seconds, or if photocell fails
or remain engaded for more than 60 seconds, the open, close, k button and pedestrian
commands will work only in dead man mode.
The signal that this mode has been activated is given by the blinking of the programming led.
With the blinking of the programming led, the opening and closing operation are allowed
only with the command button pressed and held. The radio commands and that of automatic
closing, will be excluded, since their use in this mode, is not allowed by the norms.
Once the failing safety device is repaired, in automatic after 1 second, all standard
commands that were selected, such as step by step, automatic mode, radio commands and
automatic closing start functioning again.
Note 1: during this functioning in dead man mode, in case of damage to the safety strips
(or photocells) the photocells (or safety strips) still work by interrupting the operation
in progress.
Note 2: the stop command is not to be considered a safety command that can be bypassed
in this mode. Therefore, when pressed or damaged, it will not allow any movement
of the gate.
The dead-man operation is only an emergency operation which must be activated
for a very short period and with the complete installation at sight so to have a
secure and safe control of the system. As soon as possible however, the failing
safety devices must be repaired and activated.
BLINKER
N.B.: This control panel can power ONLY BLINKERS ON A (ACG7061) CIRCUIT with lamps
up to 24V and 20W.
PRE-BLINKING
DIP 5 - OFF => the motor and blinker begin simultaneously.
DIP 5 - ON => the blinker begins 3 seconds before the motor.
GATE OPEN WARNING LIGHT (COM-SIGNAL)
Signals when the gate is open, partially open or not closed completely. Turns off only when
the gate is completely closed. This signal is active during programming. N.B.: Max 3 W. If
push buttons or lamps are in excess, the control panel processes will be endangered and
possibly halt operation.
OPERATION AFTER A BLACK-OUT (WITHOUT BATTERIES)
When the power supply comes back the DL1 led turns on and remains on for all the time
the gate stays open. The led will turn off only once the gate is completely closed. It is
recommended to fully open the gate. Let the gate close by itself or with automatic closing,
or wait until the blinker stops flashing before commanding it to close.
This will allow the gate to realign. If, motors were released and moved from the normal
position when closed during the blackout, the first movement after power returns must be
complete.
If the black out occurs when the gate is still moving or when the gate is open and the first
command sent after the black out is a closing command, the closing of the gate will be
carried out with a total delay between the two gate leaves. Therefore, first the leaf M2 will
close completely; once it is off, M1 will start closing. This separate movement of the two
gate leaves is done to avoid their incorrect overlapping.
TECHNICAL SPECIFICATIONS
- Temperature range
0 ÷ 55 °C
- Humidity<95 % without condensation
- Voltage
230 V~ ± 10% (120 V 60 Hz upon request)
- Frequency
50/60 Hz
- Battery power
20-24 Vdc
- Transformer Power130VA - primary 230 Vac - secondary 18 Vac
- Maximum absorption
50 mA
- Network Micro-switches
100ms
- Maximum power gate open indicator24 Vdc 3 W (equivalent to one 3 W or 5 LED light
bulb with resistor in series at 2,2 KΩ)
- Maximum blinker power
24 Vdc 20 W
- Power available for photocells and accessories 1A ± 15%
- Power available for radio connector 200 mA
RADIO SPECIFICATIONS (model T2 24V CRX)
- Receiving Frequency
433,92 MHz
- Impedance
52 Ω
- Sensitivity
>2,24 µV
- Pick-up time
300 ms
300 ms
- Drop time
- All inputs must be used as clean contacts because the power is generated internally
(secure power) to the board and is set up to ensure compliance with double or reinforced
insulation with regard to dangerous voltage.
- Any external circuits connected to the outputs of the control panel must be made in such
a manner as to ensure compliance with double or reinforced insulation with regard to
dangerous voltage.
- All inputs are controlled by a programmed integrated circuit that performs a self check
every time it starts operating.
TROUBLE SHOOTING
After having carried out all connections, by carefully following the layout and having
positioned the gate in intermediate position, check the correct ignition of red LEDS DL7,
DL8 and DL9
In case of no ignition of the LEDS, always with gate in intermediate position, check the
following and replace any faulty components.
DL7 switched OFF Faulty photocells
DL8switched OFF
Faulty safety edge (In case the edge is not connected, carry out
jumper between COM and EDGE)
DL9switched OFF
Stop button malfunction (if Stop is not connected, perform the jump
between COM and STOP).
During functioning with personnel present, with DIP 1 at ON, check that during opening of
M1 and M2 the green DL2 and DL4 LEDS switch on and that during closing of M1 and M2
the red DL3 and DL5 LEDS switch on.
Or else, reverse the wires of the motor.
FAULT
SOLUTION
After having carried out the various connections and having supplied Check fuses F1, FUSE 1.
voltage, all the LEDS are switched off.
If the fuse is blown, use only a suitable replacement.
F1 T 2ATRANSFORMER PROTECTION FUSE (on the outside of the T2 24V board)
FUSE 1 8A MOTOR PROTECTION FUSE
The motor opens and closes, but it has no strength and moves slowly.
Check trimmers RUN and LOW-SPEED adjustment.
The gate opens but does not close after the time set.
Make sure that the TCA trimmer is activated with LED DL6 on.
OPEN button always on, replace the OPEN control button or switch.
Sensor Auto test failed, check the connections between the control panel and the sensor power supply.
Warning: If you are not using a power supply for the sensors, DIP 12 should be OFF.
The gate does not open or close by activating the various K, Radio, Open Faulty safety edge contact. Faulty photocells contact with DIP 4 OFF.
and Close buttons.
Fix or replace the relative contact.
The electric lock does not work.
Ensure to have enabled DIP 8 at ON.
LED DL1 blinks rapidly and no movement is activated.
Place dip switches 1, 2 or 3 in the OFF position.
35
G
B
ACCESSORIES
For the connections and the technical data of the optional equipments follow the relevant handbooks.
LONG LEVER
STRONG BOX STONE
The long lever is suggested for a leaf with a distance up to 500 mm between the hinge
of the leaf and the internal side of the pillar.
code ACG8034
It is a strong metal (die-cast aluminium) container with lock to protect manual release and/or
push button. It is provided with a rocker switch and unlocking device (needs cable ACG8022). It
has to be embedded in the wall. In die-cast aluminium - IP54 code ACJ9078
STRONG BOX FLAT
UNLOCKING CABLE
It is a strong metal (die-cast aluminium) container with lock to protect manual release and/or
push button. It is provided with a rocker switch and unlocking device (needs cable ACG8022).
It has to be fitted onto the wall.
In die-cast aluminium - IP54
code ACJ9071
Cable for manual releasing the operators from outside, to be connected to strong box.
code ACG8022
ELECTRIC LOCK
Horizontal lock - right external view - 12Vac
Horizontal lock - left external view - 12Vac
Vertical lock - 12Vac
code ACG8660
code ACG8670
code ACG8650
T2 24V Wi-Fi
Control panel with impact sensors and MASTER Wi-Fi card.
With container.
code ABT2025W
36
BATTERY
BATTERY CHARGE CARD
Battery 2,2Ah 12V
code ACG9515
code ACG4648
D
ANLAGEN LAY-OUT
2
7
3
TECHNISCHE DATEN DES ANTRIEBES
PREMIER 24V ist ein irreversibler Operator, der für das Bewegen von Flügeltoren
von einer Länge bis zu 3 m eingesetzt wird (Fig. 1).
PREMIER 24V ist so konzipiert worden, dass die Endläufe nicht elektrisch
sondern mechanisch betrieben funktionieren.
Wenn die Schlagstelle erreicht ist, bleibt der Motor noch einige Sekunden
beansprucht, und solange aktiv bis der Timer, oder der Stromsensor die
Funktion der Steuerzentrale übernimmt.
4
TECHNISCHE
EIGENSCHAFTEN
5
1
6
1
5
4
PREMIER 24V
Max. Torflügelweite
m
3
Max. Torgewicht
kg
300
Mittlere Öffnungszeit zirka
s.
17
Anlaufmoment maximal Schub
Nm
1
1 - E-Torantrieb PREMIER 24V
2 - Antenne
3 - Blinkleuchte
4 - Schlusselschalter
5 - Photozelle Toraussenseitig
6 - Sperriegel
7 - Elektroschloss
150
230V~ 50Hz
Stromspannung und frequenz
Motorleistung
W
Stromaufnahme
A
0,311
Normative Zyklen
n°
∞ - 17s/2s
Zyklen rieten einem Tag
n°
Service
72
60
80%
Garantierte nachfolgende Zyklen
n°
60/17s
Motorgewicht
kg
7,5
Geräusch
db
<70
Volumen
m3
0,0184
Betriebstemperatur
°C
-30 ÷ +55°C
Schutzart
IP
44
Abmessungen in mm / inch
37
D
INSTALLATION PREMIER
Komponenten zur Installation nach der Norm EN1253
PRÜFUNG VON DER MONTAGE
Das Flugeltor muß fest an der Angelpunkten der Träger fixiert sein, darf sich während der
Bewegung nicht biegen und ohne Reibung bewegen.
Bevor PREMIER 24V montiert wird ist es besser alle Hindernisse, die bei der Montage auftreten
können festzustellen.
Bei einem Tor wie in Abbildung 1 müssen keine Veränderungen vorgenommen werden.
Es ist erforderlich, die Charakteristiken des Tors an die geltenden Normen und Gesetze anzupassen.
Das Tor kann nur automatisch Angeschlossen werden, wenn es in einem einwandfreien Zustand
ist und der EN12604 entspricht.
- Das Tor welches keine Gehfluegelfunktion hat,in diesem Fall ist es erforderlich das Tor
mit der norm EN12453 in Einklang zu bringen(z.B. das in Bewegung setzen des Motors
per Handsender, wenn der Gehfluegel geoeffnet ist. Das zu vehindern koennen sie einen
Endschalter anschliessen der beim oeffnen des Gehfluegel andere automatischen funktionen
ausser Kraft setzt).
- Darauf achten, dass sich keine Einklemmstellen ergeben (z.B. zwischen geöffnetem Tor und
seitlicher Mauer).
NOTFALL ENTBLOCKUNG MIT SCHLÜSSEL
Im Falle von Stromausfall kann man das Tor manuell mit dem dafür zuständigen Schlüssel
bewegen, indem man Den Schlüssel 180° im Uhrzeigersinn dreht (Fig. 2).
ANWENDUNG DER SCHLIESSUNG
STEUERUNGSSYSTEM
mit Totmannschaltung
Fachpersonen
(außer einem
öffentlichen
Platz*)
Fachpersonen
(öffentlicher
Platz)
Grenzlose
Anwendung
A
B
nicht möglich
mit sichtbaren
(z.B. Sensor)
C oder E
C oder E
C und D, oder E
mit nicht sichtbaren
Impulsen (Fernsender)
C oder E
C und D, oder E
C und D, oder E
automatisch
C und D,
oder E
C und D, oder E
C und D, oder E
* e in Musterbeispiel dafür sind jene Türe, die keine Zufahrt zu einem öffentlichen
Weg haben
A: Betriebstaste mit Totmannschaltung (das heißt, aktivieren sie eine Funktion, solange
man sie gedrückt hält), wie Kode ACG2013
B: Schlüsselselektor mit Totmannschaltung, wie Kode ACG1010
C: Justierbare Kraft des Motors
D: Kontaktleiste und /oder andere Sicherheitseinrichtungen muessen mit den Norm
EN12453 uebereinstimmen (Anhang A).
E: Photozelle, wie Kode ACG8026 (Jede 60÷70 cm für die ganze Höhe der Spalte des
Gatters bis zu einem Maximum von 2,5 m anwenden - EN 12445 Punkt 7.3.2.1)
NOTFALL ENTBLOCKUNG MIT AUSSEN SICHERHEITSSCHRANK
Im Falle von Stromausfall, um das Tor manuell zu bewegen genügt es, das schutzverhüllte
Stahlkabel (A) (Kode ACG8022) auf der einen Seite mit dem Hebel für die Entblockung des
Operators (B) zu verbinden und auf der anderen Seite an den Außen-Sicherheitsschrank mit
Entblocker (C) Kode ACJ9071 oder Kode ACJ9078 anzuschließen (Fig. 3).
ACHTUNG
Per poter eseguire in modo sicuro la movimentazione manuale dell’anta occorre verificare che:
- sull’anta siano presenti maniglie idonee;
- tali maniglie siano posizionate in modo da non creare punti di pericolo durante il loro utilizzo;
- lo sforzo manuale per muovere l’anta non superi i 225N per i cancelli posti su siti privati ed i
390N per i cancelli posti su siti commerciali ed industriali (valori indicati nel punto 5.3.5 della
norma EN 12453).
N.B.: Für Tore mit zwei Flügeln ist es ratsam, für eine effiziente durch Elektroschloss ausgelöste
Schließung, einen mechanischen Sperrriegel (Kode ACG5000). einzusetzen. Dieses Zubehör
wird üblicherweise unten am Torflügel montiert, und zwar an jenem der zuerst schließt. Im
Schließgang erreicht nun der zweite Torflügel den Sperrriegel und blockiert den ersten Torflügel
am Boden. Der zweite Torflügel hingegen bleibt am ersten geblockt, dank Elektroschloss, das
üblich auf halber Torhöhe montiert wird.
2
C
B
B
A
3
38
D
MOTOR HALTERUNG FIXIERUNG AN SÄULE (D)
Während der Installation des PREMIER 24V ist es nötig, dass gewisse Maßnahmen eingehalten werden, damit die Torflügelbewegung korrekt ausgeführt wird (siehe dazu Fig. 6-8).
X
138
80
80
98
13
D
4
HEBEL-MONTAGE DER ZUGSVORRICHTUNG MIT
EINDRINGSCHUTZ BLOCKSYSTEM (E)
Die Hebel-Montage gemäß Figur 5 ausführen.
Achtung: Die Schrauben V und W ganz anziehen, danach für beide
eine halbe Drehung entgegengesetzt ausführen, damit eine korrekte
Bewegung der Hebel garantiert wird. Ist der Hebel montiert, den Operator
entblocken und mit der Schraube M10 und der Unterlegscheibe am Motor
befestigen.
V
W
DRL8x17I
DRL10x20I
DRG6I
E
DRL8x17I
DRL8x17I
Das Eindringschutz Blocksystem (E) verhindert die Hebelbewegung,
wenn das Tor geschlossen ist und der Motor nicht läuft.
5
FIXIERUNG HEBEL HALTERUNG MIT DEM EINDRINGSCHUTZ BLOCKSYSTEM (E - FIG. 5)
Den Motor enthemmen.
Den Hebel bis zur Anti-Intrusion Anhaltung (E) geradebiegen, etwas die Hebel biegen so dass der Hebel (E) in Schließung nicht belasten und gebrochen wird.
α°
90
90
90
A max A max*
140
200
205
190
200
205
90
225
225
95
0
0
90
100
105
110
-
0
0
0
X
60
70
80
150
T sec
270
19
300
20
230
18
0
15
302
19
322
19
160
135
16
70
140
284
18
315
19
110
0
90
0
130
140
I
90
240
0
B
110
155
180
160
180
225
B
A
X
α
I
6
A max* - Falls nur eine Feststellvorrichtung wird benutzt auch beim Öffnung (Abb. 8).
39
D
NB: In der Fall, den Hebel zu ersetzen, benutzen Sie eine M14X20min
Schraube, den alten Hebel vom Antriebsschaft aus dem PREMIER
auszuziehen. Es ist genügend, es zum Hebel zu schrauben, um es zu
benutzen, als eine Abziehvorrichtung.
7
REGULIERUNG MECHANISCHER ENDLÄUFE
Für die Positionierung der Feststeller, diese nach Schema ausführen (Fig. 8).
Um die gewünschte Schließung bei total geschlossenem Tor zu erhalten, muss der Feststeller
(F) gegen den Zug-Hebel geschoben werden, dann wird dieser mit den zwei mitgelieferten
Versenk-Sechskant Schrauben Inox 6x20 mit einem Inbusschlüssel Nr. 5 festgeschraubt und
blockiert.
ACHTUNG: Immer zwei Schrauben für einen Feststeller benutzen.
Um die gewünschte Öffnung zu erhalten, genügt es den Feststeller (G) zu verschieben, diesen
so blockieren wie Feststeller (F).
ACHTUNG: Der Zug-Hebel des Tors ist mit einem Block-System ausgerüstet (E) (Fig.
5), dieses System wird sich nur bei forciertem Eindringen aktionieren. Wenn der
Feststeller nicht korrekt reguliert wird, wird dieses System jedes mal eingreifen, wenn das Tor
geschlossen wird, mit der Folge von Verschleiß und Beschädigung in kurzer Zeit.
G
WARTUNG
Soll nur von fachlich kompetentem Personal nach Stromabnahme ausgeführt werden.
Alle 6 Monate die Torangeln schmieren und die Aufschlagkraft des Tores überprüfen
(EN12453).
F
8
40
T2 24V
T2 24V CRX
ELEKTROANSCHLÜSSE
Kode AC07088
Kode AC07089
24Vdc 0,8A ± 15% für ZUBEHÖRE
24Vdc 0,8A ± 15% für AUTOTEST KONTAKTLEISTE
FUSSGÄNGER
EINZELIMPULS
ELEKTROSCHLOSS
FOTOZELLEN
GEMEINSAME ERDUNGSKONTAKTE
KONTAKLEISTE
LED
BLINKER
24Vdc 20W
STROMVERSORGUNG
230Vac 50 Hz
SICHERUNG
T2A
TRANSFORMATOR
R=2,2K 1/4W
GEMEINSAME
ERDUNGSKONTAKTE
SCHLIEßEN
ÖFFNEN
STOPPSCHALTER
ANTENNE
Zopfflechten
ANTENNE
M1
M2
41
D
D
J1
NF
Speisung 230 Vac 50/60 Hz - extern an der Karte (120V/60Hz auf Anfrage)
J2
COM.
Gemeinsame erdungskontakte
CLOSE
Schließung-Impuls-Kontakt (NA)
OPEN
Öffnungs-Impuls-Kontakt (NA)
STOP
Stop-Impuls-Kontakt (NC)
AERIAL
Radio Antenne
SIGNAL
Kontrollanzeigelampe Tor offen, signalisiert den Batterie
betriebenen Funktionierungsstand und leere Batterie (24Vdc
3W max)
J3
A+TEST
A - VERBINDUNGEN
J1
J2
F1
J3
TRANSFORMER
J4
Positive Ladung für die Speisung für Rippen Selbstkontrolle
EDGE N.C.
Ripppen-Kontakt (NC)
COM.
Gemeinsame Erdungskontakte
PHOTO N.C.
Fotozellen-Kontakt (NC)
K BUTT.
Einzel-Impuls-Kontakt (NA)
PED. BUTT.
Kontakt Befehl Öffnung für den Fußgängerdurchgang (NA)
A+
Positive Ladung für die Speisung für Rippen Selbstkontrolle
A-
Negative Ladung für die Speisung der Zubehöre zu 24Vdc
LOCK
Anschluss zu Elektroschloss-Riegelung (MAX 15W 12V)
FUSE 1
J9
J10
J5
Anschluss zu Blinker Negativ-Fase zu 24Vdc (Kode
ACG7061) auf die Polarität achten.
J4
SECONDARY
TRANSFORMER
Verbinder für Sekundär Transformator 18 Vac
J5
MOTOR 1
Verbindung MOTOR 1 (ohne Polarität)
J6
MOTOR 2
Verbindung MOTOR 2 (ohne Polarität)
SW T2 24V
Verbinder für die Programmierung in der Fabrik. NICHT
DIE ÜBERBRÜCKUNG BERÜHREN ! OHNE ANTRIEB NICHT
BETRIEBSFÄHIG!
SW RADIO
Verbinder für die Programmierung in der Fabrik (nur für die
Modelle CRX). NICHT DIE ÜBERBRÜCKUNG BERÜHREN !
OHNE ANTRIEB NICHT BETRIEBSFÄHIG!
J7
J8
J9
RADIO
Radio-Modul eingebaut (Modell CRX), oder Verbinder für
Radioempfänger RIB Steckverbindung mit Speisung zu
24Vdc
J10
BATTERY
CHARGER
Verbinder für Batterie-Aufladekarte zu 24Vdc (Kode
ACG4648)
TR1
TRIMMER RUN
Trimmer elektronischer Regler für hohe Geschwindigkeit
TR2
TRIMMER LOW
SPEED
Trimmer langsamlaufregler nur bei Schließung
TR3
TRIMMER TCA
Trimmer automatische schliessung vollständig oder
Teilweise - Standardeinstellung: NICHT ZUGELASSEN und
LED DL6 AUSGESCHALTET
B - EINSTELLUNGEN
J6
J8
J7
TR3
S3
TR1
DIP 1 ( ON) - STEUERUNG MOTORDREHRICHTUNG (PUNKT C)
DIP 2 (ON) - ZEITPROGRAMMIERUNG (PUNKT D)
DIP 3 ( ON) - FLÜGELFREIGABE WÄHREND DER LAUFVERLANG-SAMUNG, UND
AUCH BEI VOLLSTÄNDIGER ÖFFNUNG UND SCHLIESSUNG (IM HINBLICK AUF
DIE ANSCHLAGPROBEN LAUT EN12453)
DIP 1-2SPEICHERUNG/LÖSCHEN DER FUNKCODES FÜR BEFEHL VOLLSTÄNDIGES
SCHLIESSEN (NUR MODELL CRX) (PUNKT E)
DIP 1-3SPEICHERUNG/LÖSCHEN DER FUNKCODES FÜR BEFEHL FUSSGÄNGERÖFFNUNG (NUR MODELL CRX) (PUNKT F)
DIP 2-1ZEITPROGRAMMIERUNG FUSSGÄNGER - ÖFFNUNG BETRIEBSMIKROSCHALTER
DIP 4 F otozellen immer aktiv (OFF) - Fotozellen nur bei Schließung aktiv (ON)
DIP 5 V orblinken (ON) - Normales Blinken (OFF)
DIP 6 B efehl Einzelimpuls (K BUTT) und eingebautes Radiogerät Schritteinzelbefehl (OFF)
- automatisch (ON)
DIP 7 F unktionsweise mit Stromsensoren (ON-aktiviert) Funktion auf Zeit (OFF-aktiviert).
DIP 8 F reigabe elektrische Verriegelung (ON-aktiviert)
DIP 9 F reigabe Rückschlag elektrische Verriegelung (ON-aktiviert)
DIP 10 Freigabe Rückschlag elektrische Verriegelung (ON-aktiviert)
DIP 11 Freigabe Erleichterte Entblockung (ON-aktiviert)
DIP 12 Freigabe TEST Selbstkontrolle der Kontaktleiste (ON-aktiviert).
S3
PROG
Programmierungs-Schaltknopftaste
FUSE 1
T8A
Sicherung Motorschutz
F1
T2A
Sicherung Transformatorschutz
TR2
DIP 13 Wahlweiser Betrieb mit 1 oder 2 Motoren (Standardeinstellung: OFF 2 Motoren)
DIP 14 OFF PREMIER 24V MIT ELEKTROSCHLOSS
ON PREMIER 24V OHNE ELEKTROSCHLOSS
DIP 15 ON
DIP 16 SOFORT-SCHLIESSUNG NACH DEM PASSIEREN DER FOTOZELLEN
EINAKTIVIERT
AUSDESAKTIVIERT
JP1 =>Überbrückung muss angewählt sein!
JP2 =>Überbrückung muss angewählt sein!
JP3 =>Überbrückung muss angewählt sein!
PROG => S3 Programmierschalter
EINSTELLUNGEN
ACHTUNG: AKTIVIEREN DAS DIP 3 NÜR NACH ALLE DIE PROGRAMMIERUNGEN.
ZU BEACHTEN: MIT DIP 3 (ON) WIRD DIE FUNKTION DER KURZFRISTIGEN
FLÜGELUMKEHR NACH DEM ANSCHLAG AKTIVIERT.
DIESE KURZFRISTIGE FLÜGELUMKEHR REDUZIERT DIE STATISCHE KRAFT
INNERHALB VON 5 SEKUNDEN AUF NULL LAUT PUNKT A.2.2 DER NORM EN12453
(BETRIEBSKRÄFTE) UND ERLAUBT SOMIT DIE EINHALTUNG DER ANSCHLAGPROBEN
LAUT DERSELBEN NORM EN12453.
SOLLTE KEINE NOTWENDIGKEIT BESTEHEN, DER OBEN BESCHRIEBENEN NORM
42
D
NACHZUKOMMEN, REICHT ES AUS, DIP 3 AUF AUS ZU STELLEN. IN DIESEM FALL
SCHLIESSEN SICH DIE FLÜGEL, OHNE DIE BEWEGUNG ZU INVERTIEREN.
TRIMMER RUN (TR1) Elektronischer Regler für hohe Geschwindigkeit
Mit diesem Trimmer kann die Motorgeschwindigkeit eingestellt werden (Standardeinstellung:
Höchstgeschwindigkeit). Diese Regulierbarkeit ist von Nutzen, um die Automatik mit den
Europäischen Normen im Bezug auf den Anschlag konform zu gestalten.
TRIMMER LOW SPEED (TR2) Langsamlaufregler nur bei Schließung
Die Einstellung des Langsamlaufes erfolgt über den Trimmer LOW SPEED durch
Spannungsregulierung der Motoren (im Uhrzeigersinn drehend wird die Geschwindigkeit
erhöht). Diese Einstellung reguliert die korrekte Geschwindigkeit am Ende der Öffnung und
der Schließung je nach Torstruktur oder beim Auftreten von leichter Reibung, die die korrekte
Funktionsweise des Systems beeinträchtigen könnten.
TRIMMER AUTOMATISCHE SCHLIESSUNG TCA (TR3) VOLLSTÄNDIG ODER TEILWEISE
(FUSSGÄNGER-ÖFFNUNG) Standardeinstellung: NICHT ZUGELASSEN und LED DL6
AUSGESCHALTET (TRIMMER VOLLSTÄNDIG IM UHRZEIGERSINN GEDREHT)
Dieser Trimmer erlaubt die Zeiteinstellung vor der automatischen Schließung sowohl teilweise
als auch vollständig. Funktioniert nur bei kompletter vollständigere oder teilweiser (FußgängerÖffnung) Öffnung und eingeschalteter LED-Anzeige DL6 (Trimmer im Uhrzeigersinn gedreht).
Die Pause kann von mindestens 2 Sekunden bis maximal 2 Minuten eingestellt werden.
LED-ANZEIGEN
DL1 Programmierung aktiviert (Rot)
DL2 Tor in Öffnung M2 (Grün)
DL3 Tor in Schließung M2 (Rot)
DL4 Tor in Öffnung M1 (Grün)
DL5 Tor in Schließung M1 (Rot)
DL6 Zeitangabe automatische Schließung (Rot)
DL7 Kontakt Fotozellen (NC) (Rot)
DL8 Kontakt Kontaktleiste (NC) (Rot)
DL9 Befehl STOPP (NC) (Rot)
DL10 Programmierung Funkcodes (Grün)
SICHERUNGEN
Fuse 1 T 8A SICHERUNG MOTORSCHUTZ
F1 T 2ASICHERUNG TRANSFORMATORSCHUTZ (außerhalb des Steckverbinders T2
24V)
C - STEUERUNG MOTORDREHRICHTUNG
1 - DIP 1 auf ON stellen=> Die LED-AnzeigeDL1 beginnt zu blinken.
2 - Den Schalter PROG. drücken und gedrückt halten (die Bewegungen Öffnen-StoppSchließen-Stopp-Öffnen-usw. werden vom Steuerpult aus bedient) => DIE GRÜNEN
LED-ANZEIGEN DL2 und DL4 leuchten auf und die Flügel öffnen sich mit fixer
Phasenverschiebung von 2 Sekunden. Schließen sie sich hingegen statt sich zu öffnen,
den Schalter loslassen und die beiden Anschlüsse des betreffenden Motors invertieren.
3 - Nach der vollständigen Öffnung den Schalter PROG. loslassen und das Tarieren der
Öffnungs-Endanschläge vornehmen (am Bedienelement).
4 - Den Schalter PROG. drücken und gedrückt halten => DIE ROTEN LED-ANZEIGEROSSI
DL3 und DL5 leuchten auf und die Flügel schließen sich mit fixer Phasenverschiebung
von 2 Sekunden
5 - Den Schalter PROG bis zur vollständigen Schließung des Tors gedrückt halten.
6 - Zur Zeitprogrammierung beide Flügel vollständig geschlossen halten.
7 - DIP1 wieder auf OFF stellen => Die LED-AnzeigeDL1 erlischt und zeigt das Ende der
Kontrolle an.
ZU BEACHTEN. Während dieser Kontrolle sind der Stopp, die Fotozellen und die
Kontaktleisten nicht aktiv.
D - ZEITPROGRAMMIERUNG BEI 2 MOTOREN (#) MIT AKTIVIERTEM
STROMSENSOR (DIP 7 ON)
WÄHREND DER PROGRAMMIERUNG BLEIBT DER STROMSENSOR IMMER AKTIV:
1 - Das Tor muss vollständig geschlossen sein.
2 - DIP 2 auf ON stellen=> Die LED-AnzeigeDL1 beginnt zu blinken.
3 - Den Schalter PROG. drücken=> M1 öffnet.
4 - Nach Erreichen des Öffnungs-Endanschlages, hält der AUTOMATISCHE STROMSENSOR
M1 an (und speichert Zeit und Stromwerte) => Gleichzeitig aktiviert sich M2 und öffnet.
5 - Nach Erreichen des Öffnungs-Endanschlages, hält der AUTOMATISCHE STROMSENSOR
M2 an (und speichert Zeit und Stromwerte)
6 - Den Schalter PROG. drücken=> M2 schließt.
7 - Den Schalter PROG. drücken => M1 schließt und bestimmt die Phasenverschiebung
zwischen M2 und M1. Gleichzeitig erlischt die LED-Anzeige DL1 und zeigt das Ende der
Speicherprozedur an.
Ab diesem Zeitpunkt funktionieren die Sicherheitsbefehle des Tor normal (Umkehr, Stopp,
Alarmfunktionen, usw....).
8 - Die Schließung der Flügel erfolgt mit hoher Geschwindigkeit (je nach Einstellung des
Trimmers RUN) und mit Laufverlangsamung gegen Ende der vollständigen Schließung (je
nach Einstellung des Trimmers LOW SPEED).
9 - Bei Erreichen der vollständigen Schließung halten die Sensoren das Tor an.
10 - NACH BEENDIGUNG DER PROGRAMMIERUNG DIP 2 AUF OFF STELLEN.
D - ZEITPROGRAMMIERUNG BEI 1 MOTOR (M1) (#) MIT AKTIVIERTEM
STROMSENSOR (DIP 7 ON)
ACHTUNG: BEI NUR EINEM MOTOR MUSS DIP 13 AUF GESTELLT WERDEN ON
WÄHREND DER PROGRAMMIERUNG BLEIBT DER STROMSENSOR IMMER AKTIV.
Das Tor muss vollständig geschlossen sein.
1 - DIP 2 auf EIN stellen=> Die LED-AnzeigeDL1 beginnt zu blinken.
2 - Den Schalter PROG. drücken=> M1 öffnet.
Nach Erreichen des Öffnungs-Endanschlages, hält der AUTOMATISCHE STROMSENSOR
M1 an (und speichert Zeit und Stromwerte).
3 - Den Schalter PROG. drücken => M1 schließt.
Gleichzeitig erlischt die LED-AnzeigeDL1 und zeigt das Ende der Speicherprozedur an.
Ab diesem Zeitpunkt funktionieren die Sicherheitsbefehle des Tor normal (Umkehr, Stopp,
Alarmfunktionen, usw....).
Bei Erreichen der vollständigen Schließung halten die Sensoren das Tor an.
4 - NACH BEENDIGUNG DER PROGRAMMIERUNG DIP 2 AUF OFF STELLEN.
(#) WÄHREND DER PROGRAMMIERUNG BLEIBEN DIE SICHERHEITSBEFEHLE AKTIV
UND IHR EINGREIFEN FÜHRT ZUM ANHALTEN DER PROGRAMMIERUNG (DIE LEDANZEIGEDL1 BLINKT NICHT MEHR, SONDERN BLEIBT ERLEUCHTET). UM MIT DER
PROGRAMMIERUNG FORTZUFAHREN, DIP 2 AUF AUS STELLEN, DAS TOR ÜBER
DEN VORGANG “STEUERUNG MOTORDREHRICHTUNG” SCHLIESSEN UND DIE
PROGRAMMIERUNG WIEDERHOLEN.
D - ZEITPROGRAMMIERUNG BEI 2 MOTOREN (#) AUF ZEIT (DIP 7
OFF)
1 - Das Tor muss vollständig geschlossen sein.
2 - DIP 2 auf ON stellen=> Die LED-AnzeigeDL1 beginnt zu blinken.
3 - Den Schalter PROG. drücken=> M1 öffnet.
4 - 1 Sekunde nach Erreichen des Öffnungs-Endanschlages, den Schalter PROG. drücken=>
M1 schließt und M2 öffnet.
5 - 1 Sekunde nach Erreichen des Öffnungs-Endanschlages, den Schalter PROG. drücken
=> M2 schließt.
6 - Den Schalter PROG. drücken. => M2 schließt.
7 - Den Schalter PROG. drücken => M1 schließt und bestimmt die Phasenverschiebung
zwischen M2 und M1
Gleichzeitig erlischt die LED-AnzeigeDL1 und zeigt das Ende der Speicherprozedur an.
Ab diesem Zeitpunkt funktionieren die Sicherheitsbefehle des Tor normal (Umkehr, Stopp,
Alarmfunktionen, usw...).
8 - Nach der Zeitbestimmung schließt das Tor
9 - NACH BEENDIGUNG DER PROGRAMMIERUNG DIP 2 AUF OFF STELLEN.
ANMERKUNG: Die Laufverlangsamung wird automatisch durch die Steuerung während
der Zeitprogrammierung bestimmt und wird etwa 50÷60 cm vor dem Öffnungs- oder
Schließungs-Endanschlag aktiviert.
D - ZEITPROGRAMMIERUNG BEI 1 MOTOR (#) AUF ZEIT (DIP 7 OFF)
ACHTUNG: BEI NUR EINEM MOTOR MUSS DIP 13 AUF GESTELLT WERDEN EIN
1 - Das Tor muss vollständig geschlossen sein.
2 - DIP 2 auf ON stellen=> Die LED-AnzeigeDL1 beginnt zu blinken.
3 - Den Schalter PROG. drücken => M1 öffnet.
4 - 1 Sekunde nach Erreichen des Öffnungs-Endanschlages, den Schalter PROG. drücken=>
M1 schließt.
5 - Den Schalter PROG. drücken => M1 schließt.
Gleichzeitig erlischt die LED-AnzeigeDL1 und zeigt das Ende der Speicherprozedur an.
Ab diesem Zeitpunkt funktionieren die Sicherheitsbefehle des Tor normal (Umkehr, Stopp,
Alarmfunktionen, usw....).
6 - Nach der Zeitbestimmung schließt das Tor.
7 - NACH BEENDIGUNG DER PROGRAMMIERUNG DIP 2 AUF OFF STELLEN.
D - PROGRAMMIERUNG ÖFFNUNGSZEITEN FUSSGÄNGER-ÖFFNUNG (#)
SOWOHL AUF ZEIT ALS AUCH MIT AKTIVIERTEM STROMSENSOR
Bei geschlossenem Tor:
1 - DIP2 auf ON schalten (Die LED-AnzeigeDL1 blinkt rasch) und dann DIP1 auf ON stellen
(Die LED-AnzeigeDL1 blinkt langsam).
43
D
2 - Den Fußgängerschalter drücken (COM-PED.BUTT) => M1 öffnet.
3 - Den Fußgängerschalter drücken um das Tor anzuhalten (auf diese Weise wird die Öffnung
von M1 bestimmt).
4 - Den Fußgängerschalter drücken um das Tor zu schließen.
5 - Ist das Tor geschlossen DIP1 und 2 auf OFF stellen.
(#) WÄHREND DER PROGRAMMIERUNG BLEIBEN DIE SICHERHEITSBEFEHLE AKTIV
UND IHR EINGREIFEN FÜHRT ZUM ANHALTEN DER PROGRAMMIERUNG (DIE LEDANZEIGEDL1 BLINKT NICHT MEHR, SONDERN BLEIBT ERLEUCHTET). UM MIT DER
PROGRAMMIERUNG FORTZUFAHREN, DIP 2 AUF OFF STELLEN, DAS TOR ÜBER
DEN VORGANG “STEUERUNG MOTORDREHRICHTUNG” SCHLIESSEN UND DIE
PROGRAMMIERUNG WIEDERHOLEN.
E-
PROGRAMMIERUNG FUNKCODES VOLLSTÄNDIGE ÖFFNUNG
(MAX. 62 CODES - NUR MODELLE CRX)
Die Programmierung erfolgt nur bei geschlossenem Tor.
1 - DIP 1 auf ON und anschließend DIP 2 auf ON stellen.
2 - Die rote LED-AnzeigeDL1 für die Programmierung blinkt mit einer Frequenz von 1 Sek.
ON und 1 Sek. OFF für 10 Sekunden.
3 - Die Fernsteuerungs-Taste (normalerweise Kanal A) innerhalb der vorgeschirebenen Zeit
von 10 Sekunden drücken. Wenn die Fernsteuerung korrekt programmiert worden ist,
blinkt die LED-Anzeige DL10 (Grün).
4-
Die Programmierzeit der Codes verlängert sich automatisch, damit die nächste
Fernbedienung programmiert werden kann. .
5 - Um die Programmierung abzuschließen, 10 Sekunden warten oder die Taste PROG
drücken. Die rote LED-Anzeige erlischt.
6 - Erneut DIP 1 und DIP 2 auf OFF stellen.
7 - Ende des Programmiervorgangs.
VORGEHEN ZUR VOLLSTÄNDIGEN LÖSCHUNG DER FUNKCODES FÜR VOLLSTÄNDIGE
ÖFFNUNG
Die Löschung kann nur bei geschlossenem Tor erfolgen.
1 - DIP 1 auf ON und anschließend DIP 2 auf ON stellen.
2 - Die rote LED-Anzeige DL1 für die Programmierung blinkt mit einer Frequenz von 1 Sek.
ON und 1 Sek. OFF 10 Sekunden lang.
3 - Die Taste PROG 5 Sekunden lang gedrückt halten. Die Löschung des Speichers wird
durch zweimaliges Blinken der grünen LED-Anzeige DL10 angezeigt.
4 - Die rote LED-Anzeige DL1 bleibt für die Programmierung aktiv und es ist jetzt möglich,
neue Codes wie oben beschrieben einzugeben.
5 - Erneut DIP 1 und DIP 2 auf OFF stellen.
6 - Ende des Programmiervorgangs.
ANZEIGE “SPEICHERKAPAZITÄT ERSCHÖPFT” FÜR DIE VOLLSTÄNDIGE ÖFFNUNG
Diese Anzeige erhält man nur bei geschlossenem Tor.
1 - DIP 1 auf EIN und anschließend DIP 2 auf EIN stellen.
2-
Die grüne LED-Anzeige DL10 blinkt 6mal und zeigt den vollen Speicher an (62
vorhandene Codes).
3 - Anschließend bleibt die LED-Anzeige DL1 10 Sekunden für die Programmierung aktiv und
erlaubt somit die vollständige Löschung aller Codes.
4 - Erneut DIP 1 und DIP 2 auf AUS stellen.
5 - Ende des Vorgangs.
F-
PROGRAMMIERUNG FUNKCODES FÜR DIE FUSSGÄNGERÖFFNUNG (MAX. 62 CODES - NUR MODELLE CRX)
Die Programmierung erfolgt nur bei geschlossenem Tor.
1 - DIP 1 auf ON und anschließend DIP 2 auf ON stellen.
2 - Die rote LED-Anzeige DL1 für die Programmierung blinkt mit einer Frequenz von 1 s ON
und 1 s OFF 10 Sekunden lang.
3 - Die Fernsteuerungs-Taste (normalerweise Kanal B) innerhalb der vorgeschriebenen Zeit
von 10 Sekunden drücken. Wenn die Fernsteuerung korrekt programmiert worden ist,
blinkt die LED-Anzeige DL10 (Grün).
4-
Die Programmierzeit der Codes verlängert sich automatisch, damit die nächste
Fernbedienung programmiert werden kann.
5 - Um die Programmierung abzuschließen, 10 Sekunden abwarten oder die Taste PROG
drücken. Die rote LED-Anzeige erlischt.
6 - Erneut DIP 1 und DIP 2 auf OFF stellen.
ANMERKUNG: WENN DIE LED-ANZEIGE DL1 STÄNDIG RASCH WEITERBLINKT,
BEDEUTET DAS, DASS DIP 1 NOCH AUF ON STEHT UND JEDER WEITERE VORGANG
UNMÖGLICH IST.
7 - Ende des Programmiervorgangs.
VORGEHEN ZUR VOLLSTÄNDIGEN LÖSCHUNG DER FUNKCODES FÜR FUSSGÄNGERÖFFNUNG
Die Löschung kann nur bei geschlossenem Tor erfolgen.
1 - DIP 1 auf ON und anschließend DIP 2 auf ON stellen.
2 - Die rote LED-Anzeige DL1 für die Programmierung blinkt mit einer Frequenz von 1 s ON
und 1 s OFF 10 Sekunden lang.
3 - Die Taste PROG. 5 Sekunden lang gedrückt halten. Die Löschung des Speichers wird
durch zweimaliges Blinken der grünen LED-Anzeige DL10 angezeigt.
4 - Die rote LED-Anzeige DL1 bleibt für die Programmierung aktiv und es ist jetzt möglich,
neue Codes wie oben beschrieben einzugeben.
5 - Erneut DIP 1 und DIP 2 auf OFF stellen.
6 - Ende des Programmiervorgangs.
ANZEIGE “SPEICHERKAPAZITÄT ERSCHÖPFT” FÜR DIE FUSSGÄNGER-ÖFFNUNG
Diese Anzeige erhält man nur bei geschlossenem Tor.
1 - DIP 1 auf ON und anschließend DIP 3 auf ON stellen.
2-
Die grüne LED-Anzeige DL10 blinkt 6mal und zeigt den vollen Speicher an (62
vorhandene Codes).
3 - Anschließend bleibt die LED-Anzeige DL1 10 Sekunden für die Programmierung aktiv und
erlaubt somit die vollständige Löschung aller Codes.
4 - Erneut DIP 1 und DIP 3 auf OFF stellen.
5 - Ende des Vorgangs.
FUNKTIONSWEISE DER STEUERZUSATZEINRICHTUNGEN
WARNUNG: VERBINDEN SIE STEUERUNG-ZUBEHÖR, NUR WENN ES AUF IMPULSMODUS.
Stellen Sie sicher, dass alle anderen Arten von Steuerung-Zubehör (z.B.
Magnetsensoren) auf IMPULS-Modus programmiert ist, da es die Bewegung des
Tores ohne aktive Sicherheiten aktiviert.
STEUERTASTE FÜR SCHRITTWEISEN BETRIEB (COM-K BUTTON)
DIP 6 OFF =>führt einen Befehl der Steuerreihe Öffnen-Stopp-Schließen-Stopp-Öffnen
usw. aus.
DIP 6 ON =>sorgt die für die Öffnung des geschlossenen Tors. Reagiert nicht, wird
die Taste während der Öffnungsbewegung gedrückt. Wird die Taste bei
offenem Tor gedrückt so wird das Tor geschlossen, drückt man sie bei
geschlossenem Tor, führt das zur Öffnung.
ÖFFNUNGS-TASTE (COM-OPEN)
Bei stillstehendem Tor steuert diese Taste die Öffnungsfunktion an, wird sie während des
Schließvorganges gedrückt, so wird das Tor wieder geöffnet.
DIE UHR-FUNKTON DER SCHALTTASTE ÖFFNUNG
Wenn Sie eine Uhr (oder einfach einen Schalter) gelten zu öffnen und offen zu
halten, das Tor wollen, müssen Sie auf T2 24V mit fw 03 NOUP fragen.
Wenn fw 03 oder höher ACHTUNG: Bei Ausfall der Sicherheit, eine Minute
nach dem Uhr oder Schalter wurden aktiviert, wird das Tor zu öffnen “OHNE
SICHERHEITS ACTIVE!
Diese Funktion ist besonders zur Stoßzeit nützlich, wenn der Verkehrsfluss langsam ist (zum
Beispiel bei Schichtwechsel, Notfälle im Wohn- oder Parkplatzbereich und vorrübergehend
bei Umzügen).
FUNKTION UHR ANBRINGUNGSART
Anfragen Sie T2 24V mit Firmware 02. Durch Anschluss eines Schalter und /oder einer
Uhr mit Tages/Wocheneinstellung (anstatt der oder parallel zur Öffnungstaste “COM-OPEN”),
kann das Tor in der Automatikeinstellung offen gehalten werden, bis der Schalter gedrückt
wird oder die eingestellte Uhrzeit erreicht wurde. Bei geöffneter Automatikeinstellung werden
alle Steuerfunktionen unterdrückt.
In dem Loslassen des Schalters, oder wenn die eingestellte Zeit abgelaufen, haben Sie die
sofortige Schließung der Automation.
SCHLIESSUNGS-TASTE (COM-CLOSE)
Führt bei stillstehendem offenem Tor zur Schließung.
FERNSTEUERUNG
DIP 6 OFF =>führt einen Befehl der Steuerreihe Öffnen-Stopp-Schließen-Stopp-Öffnen
usw. aus.
DIP 6 ON =>sorgt die für die Öffnung des geschlossenen Tors. Reagiert nicht, wird
die Taste während der Öffnungsbewegung gedrückt. Wird die Taste bei
offenem Tor gedrückt so wird das Tor geschlossen, drückt man sie bei
geschlossenem Tor, führt das zur Öffnung.
44
D
TASTE ZUR FUSSGÄNGER-ÖFFNUNG (COM-PED.BUTT.)
Befehl für eine teilweise Öffnung mit nachfolgender Schließung.
Während der Öffnung der Pause oder der Schließung der Fußgänger-Öffnung, kann die
Öffnung mit jedem mit dem Steckverbinder T2 24V verbundenem Befehl geöffnet werden.
Über DIP 6 kann man die Funktionsweise der Taste zur Fußgänger-Öffnung wählen.
DIP 6 OFF =>führt einen Befehl der Steuerreihe Öffnen-Stopp-Schließen-Stopp-Öffnen
usw. aus.
DIP 6 ON =>sorgt die für die Öffnung des geschlossenen Tors. Reagiert nicht, wird
die Taste während der Öffnungsbewegung gedrückt. Wird die Taste bei
offenem Tor gedrückt so wird das Tor geschlossen, drückt man sie bei
geschlossenem Tor, führt das zur Öffnung.
ELEKTRISCHE VERRIEGELUNG (LOCK)
DIP 8 auf ON stellen, um den Befehl für die elektrische Verriegelung während der Öffnung
zu aktivieren.
FREIGABE ELEKTRISCHE VERRIEGELUNG WÄHREND DER ÖFFNUNG
DIP 9 auf ON stellen, um die Freigabe der elektrischen Verriegelung während der Öffnung zu
aktivieren (dabei muss DIP 8 auf ON stehen).
Wird bei geschlossenem Tor ein Öffnungsbefehl gegeben, so führt das Tor für 0,5s eine
Schließbewegung aus und gleichzeitig wird die elektrische Verriegelung aktiviert (gefolgt von
einer Pause von 0,5s und der Öffnung des Tors).
FREIGABE ELEKTRISCHE VERRIEGELUNG
DIP 10 auf ON stellen, um die Freigabe der elektrischen Verriegelung während der Schließung
zu aktivieren. Nach vollständiger Schließung laufen die Motoren bei voller Spannung für 0,5s
um die elektrische Verriegelung zu garantieren.
ERLEICHTERTE ENTBLOCKUNG MOTOREN
DIP 11 auf ON stellen, um die manuelle erleichterte Entblockung (DIP 10 muss dabei auf ON
stehen) auszuführen, nach der Schließung wird ein Umkehrvorgang für 0,2s durchgeführt,
um die Entblockung zu erleichtern.
FUNKTIONSWEISE SICHERHEITSEINRICHTUNGEN
FOTOZELLE (COM-PHOT)
DIP 4 OFF =>
Kommt bei geschlossenem Tor ein Hindernis in den Wirkkreis der
Fotozelle, so öffnet sich das Tor nicht. Während der Funktion des Tors
wirken die Fotozellen sowohl bei der Öffnung (mit Wiederherstellung der
Öffnungsbewegung nach einer halben Sekunde) als auch bei der Schließung
(mit Wiederherstellung der Öffnungsbewegung nach einer Sekunde).
DIP 4 ON =>
Kommt bei geschlossenem Tor ein Hindernis in den Wirkkreis der
Fotozelle und erfolgt der Öffnungsbefehl, so öffnet sich das Tor (während
der Öffnungsphase erfolgt keine Ansteuerung durch die Fotozellen). Die
Fotozellen wirken nur in der Schließungsphase (mit Wiederherstellung der
Torumsteuerung nach einer Sekunde, auch wenn die Fotozellen in Funktion
bleiben).
ÜBERWACHUNG DER SOFORTIGEN SCHLIESSUNG NACH PASSIEREN DER FOTOZELLEN
DIP 16 ON und DIP 4 OFF =>aktivieren sich die Fotozellen während der Öffnung, hält das
Tor an und schließt sich nach nur 1 Sekunde nach Freigabe
der Fotozellen
DIP 16 ON und DIP 4 ON =>aktivieren sich die Fotozellen während der Öffnung, so
öffnet sich das Tor weiter. nach Freigabe der Fotozellen hält
das Tor für 1 Sekunde an und schließt sich dann.
Wird die vollständige Öffnung erreicht (nach Ende der Öffnungszeit), wird die
sofortige Schließung ausgeschaltet und die automatische Schließzeit aktiviert
(wenn der Trimmer TCA aktiviert ist und die LED-Anzeige DL6 leuchtet).
Kommt es während der Schließung zu einem raschen Passieren (zum Beispiel
durch einen Fußgänger) öffnet sich das Tor für 2 Sekunden, um sich anschließend
erneut zu schließen.
DIP 12 OFF => sofortige Schließung nach Passierten der Fotozellen deaktiviert.
ZU BEACHTEN: Es wird empfohlen, die Funktionsweise der Fotozellen mindestens alle 6
Monate zu überprüfen.
EDGE (KONTAKTLEISTE) (COM-EDGE)
Wenn eingeschaltet, kehrt diese Funktion die Bewegung während einer Öffnung in eine
Schließbewegung um.
Wenn eingeschaltet, kehrt diese Funktion die Bewegung während einer Schließung in eine
Öffnungsbewegung um.
Bleibt die Kontaktleiste eingeschaltet, führt sie nach 2 Sekunden eine erneute Umkehr durch,
um dann eine erneute kleine Umkehr auszuführen und gibt dann den Alarm einer defekten
oder eingeschalteten Kontaktleiste (Kontakt NO). Bleibt die Kontaktleiste eingeschaltet
(Kontakt NO) wird keine Bewegung ermöglicht. Wenn diese Funktion nicht benötigt wird, sind
die COM-EDGE-Klemmen zu überbrücken.
ÜBERWACHUNG DER SICHERHEITSKONTAKTLEISTEN (A+TEST A-)
Durch den Eingang A+TEST und DIP 12 auf ON können die Kontaktleiste/n überwacht
werden.
Die Überwachung besteht aus einem Funktionstest der Kontaktleiste, welcher bei jeder
vollständigen Öffnungsbewegung des Tors durchgeführt wird. Nach jeder Öffnungsbewegung
wird daher eine Schließbewegung nur dann zugelassen, wenn die Kontaktleiste/n den
Funktionstest bestanden hat/haben.
ACHTUNG: DIE ÜBERWACHUNG DES KONTAKTLEISTE-EINGANGS KANN MIT DIP 12 AUF
ON AKTIVIERT ODER MIT DIP 12 AUF OFF DESAKTIVIERT WERDEN: DER FUNKTIONSTEST
DER KONTAKTLEISTEN IST NUR DANN MÖGLICH, WENN ES SICH UM EINE VORRICHTUNG
HANDELT, DIE MIT EINER EIGENEN STEUERLEITUNG AUSGESTATTET IST.
EINE MECHANISCHE KONTAKTLEISTE KANN NICHT ÜBERWACHT WERDEN, DAHER MUSS
DIP 12 AUF OFF GESTELLT WERDEN.
SELBSTTEST-ALARM KONTAKTLEISTE (DIP 12 ON)
Wenn die Überwachung nach vollständiger Öffnung negativ ausfällt, wird ein BlinkleuchtenAlarm ausgelöst, der aktiviert bleibt, unter dieser Bedingung wird die Schließung des Tors
nicht zugelassen. Der Normalbetrieb kann nur durch Reparatur der Kontaktleiste und durch
Drücken einer des aktivierenden Befehls wieder aufgenommen werden.
STOPP-TASTE (COM-STOP)
Das Drücken der Stopp-Taste führt bei jedem Zustand des Tors zu dessen
Stillstand.
Wird sie bei vollständig geöffneten Tor gedrückt (oder bei Fußgänger-Öffnung), wird
vorrübergehend die automatische Schließfunktion unterbrochen (wenn diese über den
Trimmer TCA aktiviert wurde und die LED-Anzeige DL6 leuchtet). Es muss daher ein erneuter
Schließbefehl gegeben werden.
Beim anschließenden Bewegungszyklus wird die automatische Schließfunktion wieder
aktiviert (wenn diese über den Trimmer TCA aktiviert wurde und die LED-Anzeige DL6
leuchtet).
ALARM STROMSENSOR
Die Steuerung T2 24V verfügt über automatische Sensoren, welche zur Bewegungsumkehr
des Tors im Falle eines Zusammenstoßes mit Personen oder Gegenständen in Konformität
mit den geltenden Normen EN führen (immer mit Prüfgerät die den Normen entsprechenden
Werte prüfen), ohne dabei besondere Einstelllungen an der Steuereinheit ausführen zu
müssen, da diese durch eine spezielle interne Software gesteuert wird.
Falls nach einem ersten Eingreifen der Stromsensoren bei Öffnung oder Schließung (nur
bei hoher Geschwindigkeit) ein zweites Eingreifen erfolgt, natürlich im umgekehrten Sinn,
schließt sich das Tor und kehrt dann für eine Sekunde seine Bewegung um.
Der Alarmzustand wird durch den Blinker angezeigt, der für eine Minute aktiv bleibt, während
dieser Zeitspanne ist eine Stabilisierung der Funktionsweise des Tores durch Drücken einer
beliebigen Befehlstaste möglich.
ARBEIT IM MANNSBEISEIN IM FALL EINES AUSFALLS DER SICHERHEITEN
Wenn die Kontaktleiste ist defekt oder diese arbeit länger als 5 Sekunden, oder wenn
die Fotozelle defekt ist oder für mehr als 60 Sekunden arbeit, die Befehle ÖFFNEN,
SCHLIESSEN, K und FUßGÄNGERZONE- TASTE im Mannsbeisein arbeiten.
Die Aktivierung dieser Meldefunktion wird durch die Programmier-LED blinkt gegeben.
Dieser Vorgang darf geöffnet oder geschlossen werden nur durch Halten der Tasten steuern.
Die Funksteuerung und automatische Schließung sind ausgeschlossen, weil ihr Betrieb nicht
an die Regeln erlaubt.
Nach der Wiederherstellung der Sicherheit , ist nach einer Sekunde automatisch in
automatischen Funktion oder Schritt für Schritt restauriert, und damit auch die Fernbedienung
und das automatische Schließen wieder möglich.
Anmerkung 1: Während dieses Vorgangs, im fall eines ausfalls der Kontaktleisten
(oder Fotozellen) der Fotozellen (oder Kontaktleisten) funktionieren noch,
Unterbrechung des Betriebs im Gange.
Anmerkung 2: Die Stoppen-Taste ist nicht als Sicherheitseinrichtung in diesem Modus
anzusehen; so wenn gedrückt oder kaputt, erlauben Sie keines Manöver.
Die “Totmannschaltung” Bedienung ist nür eine Not-Bedienung und die, für kurze
Zeit und mit der Visuell-Sicherheit der Autmatismum-Bewegung gemacht wird
sein. So bald wie möglich, muss der Fehler Schutz, für den ordnungsgemäßen
Betrieb, wiederhergestellt werden sein.
BLINKLICHT
45
D
ZU BEACHTEN: Diese Steuereinheit kann NUR BLINKER MIT BLINKKREISLAUF (ACG7061)
mit Glühbirnen zu 24V und maximal 20W speisen.
- Höchstbelastung am Blinker-Ausgang
24 Vdc 20 W
- Verfügbarere Strom für Fotozellen und Zubehör
1 A ±15 %
- Verfügbarere Strom auf der Funkgerätsteckverbindung 200 mA
FUNKTION VORBLINKEN
DIP 5 - OFF => der Motor und der Blinker aktivieren sich gleichzeitig.
DIP 5 - ON => der Blinker aktiviert sich 3 Sekunden vor dem Motor.
TECHNISCHE EIGENSCHAFTEN FUNKGERÄT (Modell T2 24V-CRX)
- Empfangsfrequenz
433,92 MHz
- Widerstand
52 Ω
- Empfindlichkeit
>2,24 µV
- Erregungszeit
300 ms
- Entregungszeit
300 ms
ANZEIGELEUCHTE TOR GEÖFFNET (COM-SIGNAL)
Diese Anzeige hat die Aufgabe, die jeweiligen Bewegungszustände (offen, teilweise
offen, noch nicht vollständig geschlossen) des Tors anzuzeigen. Nur bei vollständig
geschlossenem Tor erlischt sie.
Während der Programmierung ist diese Anzeige aktiv.
ZU BEACHTEN: Max 3 W. Bei übermäßigen Einsatz der Tasten oder der Lampen kann
die Logistik der Steuereinheit in ihrer Funktionsweise beeinträchtigt werden, was zum
Stoppen von Bewegungsabläufen führen kann.
- Alle Eingänge müssen frei von Verunreinigungen sein, da die Speisung im Inneren der
Steckverbinder erzeugt wird, damit so die doppelte oder verstärkte Isolierung gegenüber
Teilen mit gefährlicher Spannung garantiert bleibt.
- Eventuelle an den Ausgängen der Steuereinheit angeschlossene Außenschaltkreise
müssen ausgeführt werden, damit doppelte oder verstärkte Isolierung gegenüber Teilen
mit gefährlicher Spannung garantiert bleibt.
- Alle Eingänge werden von einem programmierten integrierten Schaltkreis gesteuert, der
bei jeder Inbetriebnahme eine Selbstkontrolle einleitet.
FUNKTIONSWEISE NACH STROMAUSFALL (OHNE BATTERIE)
Nach der Rückkehr der Netzspannung LED DL1 sich einschaltet und bleibt die ganze Zeit.
LED DL1 sich abschaltet zum Erreichen der kompletten Schließung des Tores.
Sobald die Stromversorgung wiederhergestellt ist, wird empfohlen, das Tor vollständig
zu öffnen. Das Tor sollte sich dann selbständig schließen bei automatischer Schließung
oder warten, bis der Blinker nicht mehr blinkt, um dann den Schließbefehl zu erteilen.
Dieser Vorgang dient zur Ausrichtung des Tores. Bleiben während des Stromausfalles die
Motoren blockiert und werden von ihrer normalen Schließposition entfernt, muss nach
Wiederherstellung der Stromversorgung ein kompletter Bewegungszyklus ausgeführt
werden.
Wenn der Stromausfall tritt während der Bewegung, oder mit geöffnet Tor, und
der erste Befehl die Schließungsbefehl ist, wird die Schließung mit der gesamten
Phasenverschiebung den Türen so, zuerst M2 schließt und nach Ausschaltung M1
schließt. Die separate Bewegung der zwei Motoren verhindert die Überlappung der Türen.
LÖSUNG VON PROBLEMEN
Nachdem alle Verbindungen sorgfältig dem Schema folgend ausgeführt wurden und das
Tor auf die mittlere Position gestellt wurde, das korrekte Einschalten der rot LEDs DL7
und DL8 und DL9 kontrollieren.
Im Fall, dass sich ein LED, mit dem Tor immer noch in mittlerer Position, nicht einschaltet,
wie folgt überprüfen und eventuelle, beschädigte Komponenten ersetzen.
Fotozellen beschädigt
DL7 ausgeschaltet
DL8ausgeschaltet
Sicherheitsrippe Schaden (Falls die Rippe nicht angeschlossen
ist einen Überbrückungsdraht zwischen COM und EDGE
legen)
DL9ausgeschaltet
Stopp-Taste defekt (falls die Stopp-Taste nicht verbunden ist,
eine Überbrückung zwischen COM und STOP anlegen).
TECHNISCHE EIGENSCHAFTEN
- Temperaturbereich
0 ÷ 55°C
- Feuchtigkeit
< 95% ohne Kondensierung
- Versorgungsspannung230V~ ±10% (120V/60Hz
auf Anfrage)
- Frequenz
50/60 Hz
20-24Vdc
- Batterieversorgung
- Transformatorleistung
130 VA
primär 230 Vac
sekundär 18 Vac
- Maximale Stromaufnahme
50 mA
100ms
- kurze Stromunterbrechungen
- Höchstleistung Kontrollleuchte Tor geöffnet24 Vdc 3 W (entspricht 1
Glühbirne mit 3 W oder 5
LED mit Serienwiderstand von
2,2 KΩ)
Während der Totmannfunktion mit DIP 1 auf ON gestellt überprüfen, dass sich während
der Öffnung von M1 und M2 die grünen LEDs DL2 und DL4 einschalten und dass bei der
Schließung von M1 und M2 die roten LEDs DL3 und DL5 aufleuchten.
Im gegenteiligen fall die Anschlüsse des betreffenden Motors invertieren.
FEHLER
LÖSUNG
Nachdem die verschiedenen Verbindungen gelegt sind und Strom angelegt wurde, sind alle
LEDs ausgeschaltet.
Die Unversehrtheit der Sicherungen F1, FUSE 1 überprüfen.
Die Sicherungen mit geleichwerteigen ersetzen.
F1 T 2ASICHERUNG ZUM TRANSFORMATORSCHUTZ (außerhalb des Steckverbinders
T2 24V)
FUSE 1 8A SICHERUNG ZUM MOTORSCHUTZ
Der Motor öffnet und schließt, aber hat keine Antriebskraft und bewegt sich langsam.
Regulierung der Trimmer RUN und LOW-SPEED überprüfen.
Das Tor führt die Öffnung aus, schließt aber nicht nach der Zeit, die eingestellt ist.
Kontrollieren, dass der Trimmer TCA aktiviert ist und die LED-Anzeige DL6 leuchtet.
Taste OPEN immer eingeschaltet, die Taste des OPEN-Befehls ersetzen.
Bei nichtbestandenem Autotest der Kontaktleiste, die Verbindungen zwischen Steuereinheit
und Speisegerät für die Kontaktleisten überprüfen. Achtung: verwendet man kein Speisegerät
für Kontaktleisten, Dip 12 auf OFF stellen.
Das Tor öffnet und schließt beim Betätigen der verschiedenen K, Radio, Open und Close
Tasten nicht.
Kontakt Sicherheitsrippe Schaden. Kontakt Fotozellen Schaden mit DIP 4 OFF.
Den entsprechenden Kontakt in Ordnung bringen oder ersetzen.
Das elektrische Schloss funktioniert nicht.
Vergewissern, dass DIP 8 auf ON gestellt ist.
Die LED-AnzeigeDL1 blinkt rasch und keine Bewegung wird zugelassen.
Die Dip Switch 1, 2 oder 3 auf OFF stellen.
46
OPTIONEN
D
Für die Anschlüsse und die technischen Daten der Zubehöre verweisen wir auf die entsprechenden Betriebsanleitungen.
LANGER HEBEL
SICHERHEITSSCHRANK STONE
LANGER HEBEL für Tore mit 50 Zentimeters Entfernung von der Saule Kante
Kode ACG8034
Behälter als Sicherheit, zur Verhinderung zum Zugang und Benutzbarkeit der
Steuerbedienungsanordnung. Wird in Serie geliefert, komplett mit Schalttasten (auf-unter)
(öffne-schließe und für die Entblockung. Benötigt das Kabel ACG8022.
Aus Aluminium Druckguss - IP54
Kode ACJ9078
SICHERHEITSSCHRANK FLAT
KABEL FÜR DIE EXTERNE ENTBLOCKUNG
Behälter als Sicherheit, zur Verhinderung zum Zugang und Benutzbarkeit der
Steuerbedienungsanordnung. Wird in Serie geliefert, komplett mit Schalttasten (auf-unter)
(öffne-schließe und für die Entblockung. Benötigt das Kabel ACG8022.
Aus Aluminium Druckguss - IP54 Kode ACJ9071
Kabel für die externe Entblockung, anzuschließen an den Sicherheitsschrank
Kode ACG8022
ELEKTRO-SCHLOSS
Horizontal-Schloss - rechts extern12Vac
Horizontal-Schloss - links extern12Vac
Vertikal-Schloss - 12Vac
BATTERIE
Kode ACG8660
Kode ACG8670
Kode ACG8650
Batterie 2,2Ah 12V
Kode ACG9515
T2 24V Wi-Fi
Steuereinheit mit Anschlagsensoren und Steckverbinder MASTER Wi-Fi. Mit Gehäuse.
Kode ABT2025W
47
BATTERIE LADEKARTE
Kode ACG4648
E
S
DISPOSICIÒN DE LA INSTALACIÒN
2
7
3
CARACTERÍSTICAS TÉCNICAS
PREMIER 24V es un operador irreversible utilizado para desplazar cancelas con
batientes con puertas largas de hasta 3 m (Fig. 1).
PREMIER 24V ha sido concebido para funcionar sin finales de carrera eléctricos,
sino sólo mecánicos.
Cuando llega de golpe, el motor funciona todavía por algunos segundos, hasta
cuando no interviene el timer de funcionamiento de la central de mando o el
sensor de corriente.
4
CARACTERÍSTICAS
TÉCNICAS
5
1
6
1
5
4
PREMIER 24V
Longitud máxima de la anta
m
3
Peso máx cancela
kg
300
Tiempo de abertura
s.
17
Momento torsional máx. de empuje
Nm
1
1 - Operador PREMIER 24V
2 - Antena de radio
3 - Intermitente
4 - Interruptor de llave
5 - Fotocélulas esternas
6 - Pestillo
7 - Cierre eléctrico
150
230V~ 50Hz
Alimentación e frequenza
Potencia motor
W
Absorcion
A
0,311
Ciclos normativos
n°
∞ - 17s/2s
Ciclos diarios sugeridos
n°
Servicio
72
60
80%
Ciclos garantizados
n°
60/17s
Peso motor
kg
7,5
Nivel de ruido
db
<70
Volume
m3
0,0184
Temperatura de trabajo
°C
-30 ÷ +55°C
Nivel de protección
IP
44
Medidas en mm / inch
48
E
S
INSTALACIÓN PREMIER
CONTROLES DE LA PRE-INSTALACIÓN
La puerta de batiente debe fijarse sólidamente a las bisagras de las columnas y no debe
balancearse durante el movimiento.
Antes de proceder a la instalación de PREMIER 24V, es prudente verificar todos los espacios
necesarios para emplazarlo. Si la cancela se presenta como en la Fig. 1, no hace falta efectuar
ninguna modificación.
N.B. Es obligatorio adecuar las características de la cancela a las normas y leyes
vigentes.
La puerta puede ser automatizada sólo si se encuentra en buen estado y responde a la norma
EN 12604.
- La puerta no tiene que tener puertas peatonales. De lo contrario se tendrán que tomar las
oportunas precauciones de acuerdo con el punto 5.4.1 de la EN12453 (por ejemplo impedir
el movimiento del motor cuando la puertecilla está abierta, gracias a un microinterruptor
debidamente conectado a la central).
- No hay que generar puntos de captura (por ejemplo entre la puerta abierta de la cancela y
pared lateral).
DESBLOQUEO DE URGENCIA CON LLAVE
En caso de ausencia de corriente, para poder actuar manualmente sobre la cancela es
suficiente introducir la respectiva llave y girarla 180° en sentido horario (Fig. 2).
DESBLOQUEO DE URGENCIA CON CAJA FUERTE DESDE EL EXTERIOR
Componentes a instalar según la norma EN12453
USO DEL CIERRE
Personas expertas
(fuera de un área
pública*)
Personas
expertas
(área pública)
Uso ilimitado
A
B
non posivel
con impulsos a la vista
(ej. sensor)
CoE
CoE
C e D, o E
con impulso no a la
vista
(ej. telemando)
CoE
C e D, o E
C e D, o E
C e D, o E
C e D, o E
C e D, o E
TYPO DE MANDO
en presencia
alguien
automatico
de
*un ejemplo típico son los cierres que no dan a la calle.
A: Pulsador de mando en presencia de alguien, (es decir con acción mantenida), como
cód. ACG2013.
B: Interruptor de llave en presencia de alguien, como cód. ACG1010.
C: Regulacion de la fuerza del motor.
D: Nervaduras como cód. ACG3010 y / o otros dispositivos que limitan las fuerzas entre
limites de las normas EN 12453 - Appendix A.
E: Fotocélulas, como cód. ACG8026 (Da applicare cada 60÷70 cm por toda la altura de
la puerta hasta un máximo de 2,5 m (EN 12445 punto 7.3.2.1).
En caso de ausencia de corriente, para actuar manualmente sobre la cancela es suficiente
conectar el cable de acero con vaina (A) (cód. ACG8022) por un extremo a la palanca de
desbloqueo del operador (B) y por otro una caja fuerte con desbloqueo (C) cód. ACJ9071 o cód.
ACJ9078 (Fig. 3).
CUIDADO
Per poter eseguire in modo sicuro la movimentazione manuale dell’anta occorre verificare che:
- sull’anta siano presenti maniglie idonee;
- tali maniglie siano posizionate in modo da non creare punti di pericolo durante il loro utilizzo;
- lo sforzo manuale per muovere l’anta non superi i 225N per i cancelli posti su siti privati ed
i 390N per i cancelli posti su siti commerciali ed industriali (valori indicati nel punto 5.3.5
della norma EN 12453).
NB.: En el caso de cancelas con dos puertas, para un cierre eficiente mediante cierre eléctrico,
se aconseja el utilizo de un pestillo mecánico (cód. ACG5000). Este accesorio se monta
generalmente en la base de la primera puerta que se cierra. Cuando llega la segunda puerta,
ésta toca el pestillo y bloquea de esta manera la primera puerta al suelo. La segunda puerta
permanece en cambio bloqueada con la primera, gracias al cierre eléctrico que se monta
generalmente a media altura.
2
C
B
B
A
3
49
E
S
FIJACIÓN DEL ENGANCHE DEL MOTOR EN LA COLUMNA (D)
Durante la instalación de PREMIER 24V es necesario respetar algunas medidas, para obtener un buen movimiento de la puerta (ver fig. 6-8).
X
138
80
80
98
13
D
4
MONTAJE DE PALANCAS DE REMOLQUE CON
DISPOSITIVO DE BLOQUEO ANTI-INTRUSIÓN (E)
Realizar el ensamblaje de las palancas como en la figura 5.
Cuidado: Atornillar hasta el tope los tornillos V y W para luego a los dos
darles un giro en sentido inverso para garantizar el correcto movimiento
de la palanca. Una vez ensamblada la palanca, desbloquear el operador, y
fijarla en el motor con el tornillo M10 y la arandela suministrados.
V
DRL8x17I
W
DRL10x20I
DRG6I
E
DRL8x17I
DRL8x17I
El Bloqueo anti-intrusión (E) impide a la palanca moverse con la cancela
cerrada y con el motor parado.
5
FIJACIÓN DEL ENGANCHE DE LA PALANCA CON BLOQUEO ANTI-INTRUSIÓN (E - FIG. 5)
Desbloquear el operador.
Enderezar la palanca hasta el paro del tapòn anti-intrusiòn (E) y doblarla ligeramente tal que, durante el cierre, no sea tensionado el tapòn (E) en cuanto podrìa romperse en un tiempo
demasiado corto.
α°
90
90
90
A max A max*
140
200
205
190
200
205
90
225
225
95
0
0
90
100
105
110
-
0
0
0
X
60
70
80
150
T sec
270
19
300
20
230
18
0
15
302
19
322
19
160
135
16
70
140
284
18
315
19
110
0
90
0
130
140
I
90
240
0
B
110
155
180
160
180
225
B
A
X
α
I
6
A max* - En caso se utilize solamente un cierre mecànico en abertura (Im. 8).
50
E
S
NB: en caso de substituciòn de la palanca, utilizar un tornillo M14X20
min para extraer la palanca vieja del àrbol de transmisiòn del PREMIER.
Es suficiente atornillarlo en la palanca para emplearla como extractor.
7
AJUSTES DE FINALES DE CARRERA MECÁNICOS
Para posicionar los seguros actuar como en el esquema (Fig. 8).
Para obtener el cierre deseado, con la cancela completamente cerrada se tendrá que mover
el seguro (F) contra la palanca de remolque bloqueándolo luego, atornillando los dos tornillos
6x20 inox hexagonales huecos con una llave Allen n° 5.
CUIDADO: Usar siempre dos tornillos por cada seguro.
Para obtener la abertura deseada es suficiente mover el seguro (G) y bloquearlo como se
describe para el seguro (F).
CUIDADO: La palanca de remolque de la cancela está dotada de un sistema de bloqueo (E)
(Fig. 5) que debe intervenir sólo en caso de intrusión. Si el seguro de cierre no es regulado
correctamente, este sistema interviene cada vez que la cancela cierra lo que conlleva a un
daño en breve tiempo.
G
MANTENIMIENTO
Debe ser efectuado sólo por personal especializado tras haber quitado la alimentación
eléctrica.
Cada 6 meses engrasar los goznes y controlar las fuerzas de impacto de la cancela (EN12453).
F
8
51
E
S
T2 24V
T2 24V CRX
CONEXIONES ELÉCTRICAS
cód. AC07088
cód. AC07089
24Vdc 0,8A ± 15% para ACCESSORIOS
24Vdc 0,8A ± 15% para AUTOTEST COSTAS
PEATONAL
PASSO PASSO
CERRADURA
ELÉCTRICA
FOTOCÉLULAS
COMÚN
COSTAS
LED
INTERMITENTE
24Vdc 20W
ALIMENTACION
230Vac 50Hz
FUSIBLE
T2A
TRANSFORMADOR
R=2,2K 1/4W
COMÚN
CIERRE
APERTURA
STOP
ANTENA
MASA
ANTENA
M1
M2
52
E
S
J1
NF
Alimentación 230 Vac 50/60 Hz - externa a la tarjeta (120V/60Hz bajo pedido)
J2
COM.
Común de los contactos
CLOSE
Contacto para impulsos de cierre (NA)
OPEN
Contacto para impulsos de apertura (NA)
STOP
Contacto para impulsos de stop (NC)
AERIAL
Antena radio
SIGNAL
Indicador luminoso de cancela abierta y señal del estado de
funcionamiento con batería y baterías descargadas (24Vdc
3W máx)
J3
A+TEST
A - CONEXIÓN
J2
J1
F1
J3
TRANSFORMER
J4
Positivo para alimentación autotest costa
EDGE N.C.
Contacto costa (NC)
COM.
Común de los contactos
PHOTO N.C.
Contacto de las fotocélulas (NC)
K BUTT.
Contacto para impulsos individuales (NA)
PED. BUTT.
Contacto del mando abertura peatonal (NA)
A+
Positivo para alimentación accesorios 24Vdc
A-
Negativo para alimentación accesorios 24Vdc
LOCK
Conexión cerradura eléctrica (MAX 15W 12V)
FUSE 1
J9
J10
J5
Conexión fase negativa del intermitente de 24Vdc (cód.
ACG7061) Cuidado con la polaridad
J4
SECONDARY
TRANSFORMER
Conector para transformador secundario 18 Vac
J5
MOTOR 1
Conexión MOTOR 1 (sin polaridad)
J6
MOTOR 2
Conexión MOTOR 2 (sin polaridad)
SW T2 24V
Conector dedicado para la programación en fábrica. ¡NO
TOCAR EL PUENTE! ¡SI ES REMOVIDO EL OPERADOR NO
FUNCIONA!
SW RADIO
Conector dedicado para la programación en fábrica (sólo
para los modelos CRX) ¡NO TOCAR EL PUENTE! ¡SI ES
REMOVIDO EL SISTEMA DE RADIO NO FUNCIONA!
J7
J8
J7
J9
RADIO
Módulo radio incorporado (modelo CRX), o conector para
radio receptor RIB con engranaje con alimentación de 24Vdc
J10
BATTERY
CHARGER
Conector para tarjeta para la recarga de batería de 24Vdc
(cód. ACG4648)
TR1
TRIMMER RUN
Trimmer de reglamento de la alta velocidad
TR2
TRIMMER LOW
SPEED
Trimmer de reglamento de la velocidad lenta
TR3
TRIMMER TCA
Trimmer de reglamento del tiempo de esperada antes de
tener del cierre automático (por defecto NO HABILITADO y
LED DL6 APAGADO)
B - CONFIGURACIÓN
J6
J8
TR3
S3
TR1
DIP 1 ( ON) - CONTROL DEL SENTIDO DE ROTACIÓN DEL MOTOR (PUNTO C)
DIP 2 ( ON) - PROGRAMACIÓN TIEMPOS (PUNTO D)
DIP 3 ( ON) - HABILITACIÓN PARA LA LIBERACIÓN DE LAS PUERTAS DURANTE LAS
FASES DE DESACELERACIÓN, APERTURA Y CIERRE TOTAL (EN RESPETO DE
LAS PRUEBAS DE IMPACTO SEGÚN LA NORMA EN12453)
DIP 1-2MEMORIZACIÓN/CANCELACIÓN DE LOS CÓDIGOS DE RADIO PARA MANDO
DE APERTURA TOTAL (SOLO MODELOS CRX) (PUNTO E)
DIP 1-3MEMORIZACIÓN/CANCELACIÓN DE LOS CÓDIGOS DE RADIO PARA MANDO
DE APERTURA PEATONAL (SOLO MODELO CRX) (PUNTO F)
DIP 2-1PROGRAMACIÓN DE LOS TIEMPOS DE APERTURA PEATONAL
MICROINTERRUPTORES DE GESTIÓN
DIP 4 F otocélulas siempre activas (OFF) - Fotocélulas activas solo en cierre (ON)
DIP 5 P reintermitencia (ON) - Intermitencia normal (OFF)
ando impulso individual (K BUTT) y Receptor radio paso paso (OFF) - automático
DIP 6 M
(ON)
DIP 7 F uncionamiento con sensor de corriente (ON-activado) Funcionamiento por tiempo
(OFF-activado).
DIP 8 H
abilitación cerradura eléctrica (ON-activado)
DIP 9 H
abilitación golpe de desenganche de la cerradura eléctrica (ON-activada)
DIP 10 Habilitación golpe de desenganche de la cerradura eléctrica (ON- activado)
DIP 11 Habilitación desbloqueo facilitado (ON-activada)
DIP 12 Habilitación TEST monitorización costa (ON- activado).
TR2
S3
PROG
Pulsador para la programación
FUSE 1
T8A
Fusible para la protección de los motores
F1
T2A
Fusible para la protección del transformador
DIP 13 Selección funcionamiento con 1 o 2 motores (por defecto OFF 2 motores)
DIP 14 OFF PREMIER 24V CON CERRADURA ELÉCTRICA
ON PREMIER 24V SIN CERRADURA ELÉCTRICA
DIP 15 ON
DIP 16 CIERRE IMMEDIATO TRAS HABER TRANSITADO DELANTE DE LAS
FOTOCÉLULAS
ONHABILITADA
OFFDESHABILITADA
JP1 =>Verificare che il ponticello sia inserito!
JP2 =>Verificare che il ponticello sia inserito!
JP3 =>Verificare che il ponticello sia inserito!
PROG => S3 Pulsante per la programmazione
REGULACIONES
ATENCIÓN: PONER EL DIP 3 EN ON, SOLO DESPUÉS DE HABER TERMINADO TODAS
LAS PROGRAMACIÓNES.
NOTA: CON DIP 3 (ON) SE HABILITA LA FUNCIÓN DE BREVE INVERSIÓN DE LAS
PUERTAS DESPUÉS DEL IMPACTO
ESTA BREVE INVERSIÓN DE LAS PUERTAS PERMITE REDUCIR A CERO LA FUERZA
ESTÁTICA DENTRO DE LOS 5 SEGUNDOS INDICADOS POR LA NORMA EN12453 EN
EL PUNTO A.2.2 (FUERZAS ESTÁTICAS ADMISIBLES) PERMITIENDO, POR LO TANTO,
RESPETAR LAS PRUEBAS DE IMPACTO INDICADAS EN LA NORMATIVA EN12453.
EN CASO DE QUE NO SEA NECESARIO OBEDECER LA NORMA ARRIBA DESCRITA,
53
E
S
BASTA COLOCAR EL DIP 3 EN POSICIÓN OFF. EN ESTE CASO LAS PUERTAS SE
DETENDRÁN SIN INVERTIR EL MOVIMIENTO.
TRIMMER RUN (TR1) Regulador electrónico de la alta velocidad
Con este trimmer es posible regular la velocidad del motor (por defecto se configura
al máximo de la velocidad). La regulación resulta de gran utilidad, pues permite que la
automatización sea conforme a las normas europeas en materia de impactos.
TRIMMER LOW SPEED (TR2) Regulador electrónico de la velocidad lenta en
acercamiento
La regulación de la velocidad lenta se realiza actuando sobre el Trimmer LOW SPEED
mediante el cual se modifica la tensión de salida a los extremos del/ de los motor/es
(girándolo en sentido horario se aumenta la velocidad). La regulación se realiza para
determinar la correcta velocidad de final de apertura y final de cierre, en base a la estructura
de la cancela, o en presencia de rozamientos leves, que podrían comprometer el correcto
funcionamiento del sistema.
TRIMMER DE CIERRE AUTOMATICO TCA (TR3) TOTAL O PEATONAL por defecto
NO HABILITADO y LED DL6 APAGADO (TRIMMER GIRADO COMPLETAMENTE EN
SENTIDO ANTIHORARIO)
Con este trimmer es posible realizar la regulación del tiempo, antes de que se produzca
el cierre automático total o peatonal. Se obtiene solo con la puerta completamente (total)
o parcialmente (peatonal) abierta y el led DL6 encendido (con trimmer girado en sentido
horario).
El tiempo de pausa puede ser regulado por un mínimo de 2 segundos y un máximo de 2
minutos.
SEÑALIZACIONES LED
DL1 programación activada (rojo)
DL2 cancela en apertura M2 (verde)
DL3 cancela en cierre M2 (rojo)
DL4 cancela en apertura M1 (verde)
DL5 cancela en cierre M1 (rojo)
DL6 señalización del tiempo de cierre automático (rojo)
DL7 contacto fotocélulas (NC) (rojo)
DL8 contacto costa (NC) (rojo)
DL9 mando pulsador STOP (NC) (rojo)
DL10 programación códigos de radio (verde)
FUSIBLES
Fuse 1 T 8A FUSIBLE PARA LA PROTECCIÓN DE LOS MOTORES
F1 T 2AFUSIBLE PARA LA PROTECCIÓN DEL TRANSFORMADOR (externo a la tarjeta
T2 24V)
Una vez alcanzado el seguro mecánico de apertura, el SENSOR DE CORRIENTE
5-
AUTOMÁTICO detiene M2 (con memorización del tiempo y de la corriente).
6 - Presione el pulsador PROG. => M2 se cierra.
7 - Presione el pulsador PROG. => M1 se cierra determinando el espacio de desfase entre
M2 y M1. En el mismo momento el led DL1 dejará de parpadear, indicando la salida del
procedimiento de memorización.
Desde este momento, las seguridades o los otros mandos de la cancela funcionarán
normalmente (inversiones, stop, alarmas, etc.).
8 - El cierre de las puertas será ejecutado en modalidad rápida (en base a lo que se
ha configurado en el trimmer RUN) y en proximidad del cierre total en modalidad
desacelerada (en base a lo que se ha configurado en el trimmer LOW SPEED).
9 - Al alcanzar el cierre, los sensores de corriente detienen la cancela.
10 - AL FINALIZAR LA PROGRAMACIÓN VUELVA A COLOCAR EL DIP 2 EN POSICIÓN
OFF.
D - PROGRAMACIÓN DE LOS TIEMPOS PARA 1 MOTOR (M1) (#) CON
SENSOR DE CORRIENTE HABILITADO (DIP 7 ON)
ATENCIÓN: PARA GESTIONAR UN SOLO MOTOR EL DIP 13 DEBE ESTAR COLOCADO
EN POSICIÓN ON; DURANTE LA PROGRAMACIÓN EL SENSOR DE CORRIENTE ESTÁ
SIEMPRE ACTIVO.
La cancela debe estar completamente cerrada.
1 - Coloque el DIP 2 en posición ON => El led DL1 emitirá parpadeos breves.
2 - Presione el pulsador PROG. => M1 se abre.
Una vez alcanzado el seguro mecánico de apertura, el SENSOR DE CORRIENTE detiene
M1 (con memorización del tiempo y de la corriente).
3 - Presione el pulsador PROG. => M1 se cierra.
En el mismo momento el led DL1 dejará de parpadear, indicando la salida del
procedimiento de memorización. Desde este momento, las seguridades o los otros
mandos de la cancela funcionarán normalmente (inversiones, stop, alarmas, etc.).
Al alcanzar el cierre, mediante el sensor de corriente, la cancela se detiene.
4 - AL FINALIZAR LA PROGRAMACIÓN VUELVA A COLOCAR EL DIP 2 EN POSICIÓN
OFF.
(#) DURANTE LA PROGRAMACIÓN LAS SEGURIDADES ESTÁN ACTIVAS Y SU
INTERVENCIÓN DETIENE LA PROGRAMACIÓN (EL LED DL1 DE INTERMITENTE
CAMBIA A ENCENDIDO FIJO). PARA REPETIR LA PROGRAMACIÓN COLOQUE EL
DIP 2 EN POSICIÓN OFF, CIERRE LA CANCELA MEDIANTE EL PROCEDIMIENTO
DE “CONTROL DEL SENTIDO DE ROTACIÓN DE LOS MOTORES” Y REPITA LA
PROGRAMACIÓN ELEGIDA.
D-
PROGRAMACIÓN DE LOS TIEMPOS PARA 2 MOTORES (#) CON
FUNCIONAMIENTO POR TIEMPO (DIP 7 OFF)
1 - Coloque DIP 1 en posición ON => El led DL1 comienza a parpadear.
2 - Presione y mantenga presionado el pulsador PROG. (ahora el movimiento se lleva a
cabo en presencia de personas, abre-stop-cierra-stop-abre-etc.) => LOS LED VERDES
DL2 y DL4 se encienden y las puertas de la cancela se abren con un desfase fijo de 2
segundos. Si se cierran en lugar de abrirse, libere el pulsador e invierta los dos cables
del motor involucrado.
3 - Al final de la apertura, libere el pulsador PROG y realice el calibrado de los retenes
mecánicos de apertura (presentes en el operador).
4 - Presione y mantenga presionado el pulsador PROG => LOS LED ROJOS DL3 y DL5 se
encienden y las puertas de la cancela se cierran con un desfase de 2 segundos.
5 - Mantenga presionado el pulsador PROG hasta que la cancela no esté completamente
cerrada.
6 - Deje las 2 puertas completamente cerradas para efectuar la programación de los
tiempos.
7 - Vuelva a colocar DIP1 en posición OFF => El led DL1 se apaga indicando la salida del
control.
NOTA: Durante este control el stop, las fotocélulas y las costas no están activas.
1 - La cancela debe estar completamente cerrada.
2 - Coloque el microinterruptor DIP 2 en posición ON => El led DL1 emitirá parpadeos
breves.
3 - Presione el pulsador PROG. => M1 se abre.
4 - Una vez alcanzado el seguro mecánico de apertura, después de un segundo, presione el
pulsador PROG. => M1 se detiene y M2 abre.
5 - Una vez alcanzado el seguro mecánico de apertura => después de 1 segundo, presione
el pulsador PROG. => M2 si detiene.
6 - Presione el pulsador PROG. => M2 se cierra.
7 - Presione el pulsador PROG. => M1 se cierra determinando el desfase entre M2 y M1.
En el mismo momento, el led DL1 dejará de parpadear, indicando la salida del
procedimiento de memorización.
Desde este momento, las seguridades o los otros mandos de la cancela funcionarán
normalmente (inversiones, stop, alarmas, etc.).
8 - Una vez finalizado el cómputo del tiempo, la cancela se detiene.
9 - AL FINALIZAR LA PROGRAMACIÓN, VUELVA A COLOCAR EL DIP 2 EN POSICIÓN
OFF.
NOTA: La desaceleración se determina automáticamente por el cuadro electrónico en fase
de programación de tiempos, y se activa a aproximadamente 50÷60 cm antes de alcanzar
los finales de carrera mecánicos de apertura o cierre.
D - PROGRAMACIÓN DE LOS TIEMPOS PARA 2 MOTORES (#) CON SENSOR
DE CORRIENTE HABILITADO (DIP 7 ON)
D - PROGRAMACIÓN DE LOS TIEMPOS PARA 1 MOTOR (#) CON
FUNCIONAMIENTO POR TIEMPO (DIP 7 OFF)
C - CONTROL DEL SENTIDO DE ROTACIÓN DEL/DE LOS MOTOR/ES
DURANTE LA PROGRAMACIÓN EL SENSOR DE CORRIENTE ESTÁ SIEMPRE ACTIVO
1 - La cancela debe estar completamente cerrada.
2 - Coloque el DIP 2 en posición ON => El led DL1 emitirá parpadeos breves.
3 - Presione el pulsador PROG. => M1 se abre.
4-
Una vez alcanzado el seguro mecánico de apertura, el SENSOR DE CORRIENTE
AUTOMÁTICO detiene M1 (con memorización del tiempo y de la corriente)=> En el
mismo momento, se activa M2 y abre.
ATENCIÓN: PARA GESTIONAR UN SOLO MOTOR, EL DIP 13 DEBE ESTAR COLOCADO
EN POSICIÓN ON.
1 - La cancela debe estar completamente cerrada.
2 - Coloque el microinterruptor DIP 2 en posición ON => El led DL1 emitirá parpadeos
breves.
3 - Presione el pulsador PROG. => M1 se abre.
4 - Una vez alcanzado el seguro mecánico de apertura, después de un segundo, presione el
54
E
S
pulsador PROG. => M1 se detiene.
5 - Presione el pulsador PROG. => M1 se cierra.
En el mismo momento el led DL1 dejará de parpadear, indicando la salida del
procedimiento de memorización.
Desde este momento, las seguridades o los otros mandos de la cancela funcionarán
normalmente (inversiones, stop, alarmas, etc.).
6 - Una vez que el cómputo del tiempo finaliza, la cancela se detiene.
7 - AL FINALIZAR LA PROGRAMACIÓN VUELVA A COLOCAR EL DIP 2 EN POSICIÓN
OFF.
D - PROGRAMACIÓN DE LOS TIEMPOS DE APERTURA PEATONAL (#)
TANTO PARA EL FUNCIONAMIENTO POR TIEMPO COMO PARA
EL FUNCIONAMIENTO CON SENSOR DE CORRIENTE
Con la cancela cerrada:
1 - Coloque primero el DIP2 en posición ON (el led DL1 parpadea rápidamente) y después el
DIP1 en posición ON (el led DL1 parpadea lentamente).
2 - Presione el pulsador peatonal (COM-PED.BUTT) => M1 se abre.
3 - Presione el pulsador peatonal para detener la carrera (definiendo así la apertura de M1)
4 - Presione el pulsador peatonal para poner en marcha el cierre.
5 - Al alcanzar el cierre, vuelva a colocar los DIP 1 y 2 en posición OFF.
(#) DURANTE LA PROGRAMACIÓN LAS SEGURIDADES ESTÁN ACTIVAS Y SU
INTERVENCIÓN DETIENE LA PROGRAMACIÓN (EL LED DL1 DE INTERMITENTE
CAMBIA A ENCENDIDO FIJO).
PARA REPETIR LA PROGRAMACIÓN COLOQUE LOS DIP1 Y 2 EN POSICIÓN OFF,
CIERRE LA CANCELA MEDIANTE EL PROCEDIMIENTO DE “CONTROL DEL SENTIDO
DE ROTACIÓN DE LOS MOTORES” Y REPITA LA PROGRAMACIÓN ELEGIDA.
E - PROGRAMACIÓN DE LOS CÓDIGOS DE RADIO APERTURA TOTAL
(MÁX. 62 CÓDIGOS - SOLO MODELOS CRX)
La programación puede llevarse a cabo únicamente con la cancela detenida.
1 - Coloque el DIP 1 en posición ON y, sucesivamente, el DIP2 en ON
2 - El led rojo DL1 de programación parpadea con una frecuencia de 1 seg. ON y 1 seg.
OFF durante 10 segundos.
3 - Presione la tecla del mando a distancia (normalmente el canal A) dentro de los 10
segundos programados. Si el mando a distancia se memoriza correctamente, el led DL10
(verde) emite un parpadeo.
4 - El tiempo de programación de los códigos se renueva automáticamente para poder
memorizar el mando a distancia sucesivo.
5 - Para terminar la programación deje transcurrir 10 segundos o presione por un instante
el pulsador PROG. El led rojo DL1 de programación deja de parpadear
6 - Vuelva a colocar el DIP 1 en posición OFF y el DIP2 en OFF
7 - Final del procedimiento.
PROCEDIMIENTO CANCELACIÓN DE TODOS LOS CÓDIGOS DE RADIO DEDICADOS A
LA APERTURA TOTAL
La cancelación puede llevarse a cabo únicamente con la cancela detenida.
1 - Coloque el DIP 1 en posición ON y, sucesivamente, el DIP2 en ON
2 - El led rojo DL1 de programación parpadea con una frecuencia de 1 seg. ON y 1 seg.
OFF durante 10 segundos.
3 - Presione y mantenga presionado el pulsador PROG durante 5 segundos. La cancelación
de la memoria se señala mediante dos intermitencias del led verde DL10
4 - El led rojo DL1 de programación permanece activo y es posible introducir nuevos códigos
siguiendo los procedimientos arriba descritos.
5 - Vuelva a colocar el DIP 1 en posición OFF y el DIP2 en OFF
6 - Final del procedimiento.
SEÑALIZACIÓN DE MEMORIA SATURADA POR LOS CÓDIGOS DE RADIO DEDICADOS
A LA APERTURA TOTAL
La señalización se puede obtener únicamente con la cancela detenida.
1 - Coloque el DIP 1 en posición ON y, sucesivamente, el DIP2 en ON
2 - El led verde DL10 parpadea 6 veces indicando la condición de memoria saturada (62
códigos presentes)
3-
Sucesivamente, el led DL1 de programación permanece activo por 10 segundos,
permitiendo una posible cancelación de todos los códigos.
4 - Vuelva a colocar el DIP 1 en posición OFF y el DIP2 en OFF
5 - Final del procedimiento.
F - PROGRAMACIÓN DE LOS CÓDIGOS DE RADIO DE APERTURA PEATONAL
(MÁX. 62 CÓDIGOS - SOLO MODELOS CRX)
La programación puede llevarse a cabo únicamente con la cancela detenida.
1 - Coloque el DIP1 en posición ON y, sucesivamente, el DIP3 en ON
2 - El led rojo DL1 de programación parpadea con una frecuencia de 1 seg. ON y 1 seg.
OFF durante 10 segundos.
3 - Presione la tecla del mando a distancia (normalmente el canal B) dentro de los 10
segundos programados. Si el mando a distancia se memoriza correctamente, el led DL10
(verde) emite un parpadeo.
4 - El tiempo de programación de los códigos se renueva automáticamente para poder
memorizar el mando a distancia sucesivo.
5 - Para terminar la programación deje transcurrir 10 segundos o presione por un instante
el pulsador PROG. El led rojo DL1 de programación deja de parpadear
6 - Vuelva a colocar el DIP 1 en posición OFF y el DIP3 en OFF
NOTA: SI EL LED DL1 CONTINÚA PARPADEANDO RÁPIDAMENTE, SIGNIFICA QUE
EL DIP1 AÚN ESTÁ COLOCADO EN POSICIÓN ON Y CUALQUIER MANIOBRA SERÁ
DENEGADA.
7 - Final del procedimiento.
PROCEDIMIENTO DE CANCELACIÓN DE TODOS LOS CÓDIGOS DE RADIO DEDICADOS
A LA APERTURA PEATONAL
La cancelación puede llevarse a cabo únicamente con la cancela detenida.
1 - Colocar el DIP 1 en posición ON y, sucesivamente, el DIP3 en ON
2 - El led rojo DL1 de programación parpadea con una frecuencia de 1 seg. ON y 1 seg.
OFF durante 10 segundos.
3 - Presione y mantenga presionado el pulsador PROG durante 5 segundos. La cancelación
de la memoria se señala mediante dos intermitencias del led verde DL10
4 - El led rojo DL1 de programación permanece activo y es posible introducir nuevos códigos
siguiendo los procedimientos arriba descritos.
5 - Vuelva a colocar el DIP 1 en posición OFF y el DIP3 en OFF
6 - Final del procedimiento.
SEÑALIZACIÓN DE MEMORIA SATURADA CÓDIGOS DE RADIO DEDICADOS A LA
APERTURA PEATONAL
La señalización se puede obtener únicamente con la cancela detenida.
1 - Coloque el DIP 1 en posición ON y, sucesivamente, el DIP3 en ON
2 - El led verde DL10 parpadea 6 veces indicando la condición de memoria saturada (62
códigos presentes)
3-
Sucesivamente, el led DL1 de programación permanece activo por 10 segundos,
permitiendo una posible cancelación de todos los códigos.
4 - Vuelva a colocar el DIP 1 en posición OFF y el DIP3 en OFF
5 - Final del procedimiento.
FUNCIONAMIENTO ACCESORIOS DE MANDO
ADVERTENCIA: CONECTE ACCESORIOS DE COMANDO SOLO SI IMPULSIVO
Asegúrese de que cualquier otro accesorios de comando que se instalan (por
ejemplo, sensores magnéticos) están programados en el modo de IMPULSO,
de lo contrario pueden activar el movimiento de la puerta sin tener activos los
elementos de seguridad.
PULSADOR DE MANDO PASO-PASO (COM-K BUTTON)
DIP 6 OFF => E jecute un mando cíclico de órdenes abre-stop-cierra-stop-abre etc.
DIP 6 ON =>Ejecute la apertura con cancela cerrada. Si se acciona durante el movimento
de apertura, no tiene efecto. Si se acciona con la cancela abierta, la cierra
y, si se acciona durante el cierre, la vuelve a abrir.
PULSADOR DE APERTURA (COM-OPEN)
Con la cancela detenida, el pulsador ordena el mando de apertura. Si se lo acciona durante
el cierre, vuelve a abrir la cancela.
FUNCIÓN RELOJ DEL PULSADOR DE APERTURA
Si desea aplicar un Temporizador (o más simplemente un interruptor) para
abrir y mantener abierta la puerta, usted tiene que pedir la tarjeta T2 24V con
firmware version fw 03 NOUP.
Si el firmware serà version fw 03 o superior ATENCION: EN CASO DE FALLA DE
LOS ACCESSORIOS DE SEGURIDAD, UN MINUTO DESPUÉS DE HABER ACTIVADO
EL TEMPORIZADO O EL INTERRUPTOR, LA PUERTA SE ABRIRA’ SIN ACCESSORIOS
DE SEGURIDAD ACTIVOS!
La Función Reloj es útil durante las horas pico, cuando el tráfico vehicular es lento (por
ej. entrada/salida de trabajadores, emergencias en zonas residenciales o zonas de
aparcamientos y, temporalmente, por mudanzas).
MODALIDAD DE APLICACIÓN FUNCIÓN RELOJ
Solicitar T2 24V con firmware 02. Conectando un interruptor y/o un reloj de tipo diario/
semanal (en el lugar o en paralelo al pulsador de apertura N.O. “COM-OPEN”) es posible
abrir y mantener abierta la automatización hasta que el interruptor es presionado o el reloj
permanece activo. Con la automatización abierta se inhiben todas las funciones de mando.
Liberando el interruptor, o cuando expira la hora configurada, se obtendrá el cierre inmediato
55
E
S
de la automatización.
PULSADOR DE CIERRE (COM-CLOSE)
Con la cancela detenida, ordena el movimiento de cierre.
MANDO A DISTANCIA
DIP 6 OFF => Ejecute un mando cíclico de órdenes abre-stop-cierra-stop-abre etc.
DIP 6 ON =>Ejecute la apertura con cancela cerrada. Si se acciona durante el movimento
de apertura, no tiene efecto. Si se acciona con la cancela abierta, la cierra y,
si se acciona durante el cierre, la vuelve a abrir.
PULSADOR DE APERTURA PEATONAL (COM-PED BUTT.)
Mando dedicado a una apertura parcial y a su cierre.
Durante la apertura, la pausa o el cierre peatonal, es posible ordenar la apertura desde
cualquier mando conectado a la tarjeta T2 24V.
Mediante el DIP6 es posible elegir la modalidad de funcionamiento del pulsador de mando
peatonal.
DIP 6 OFF => Ejecute un mando cíclico de órdenes abre-stop-cierra-stop-abre etc.
DIP 6 ON =>Ejecute la apertura con cancela cerrada. Si se acciona durante el movimento
de apertura, no tiene efecto. Si se acciona con la cancela abierta, la cierra
y, si se acciona durante el cierre, la vuelve a abrir.
CERRADURA ELÉCTRICA (LOCK)
Coloque el DIP8 en posición ON para habilitar el mando de la cerradura eléctrica en apertura.
GOLPE DE DESENGANCHE DE LA CERRADURA ELÉCTRICA EN APERTURA
Coloque el DIP9 en posición ON para habilitar el golpe de desenganche de la cerradura
eléctrica en apertura (bajo la condición de que DIP8 esté en ON).
Con la cancela cerrada, si se presiona un mando de apertura, la cancela durante 0,5s
ejecuta la maniobra de cierre y, contemporáneamente, se activa la cerradura eléctrica
(seguida por 0,5s de pausa y por la apertura de la cancela)
GOLPE DE DESENGANCHE DE LA CERRADURA ELÉCTRICA
Coloque el DIP10 en posición ON para habilitar el golpe de desenganche de la cerradura
eléctrica en cierre. Una vez que se produjo el cierre, se gestionan por 0,5s los motores a
plena tensión para garantizar el enganche de la cerradura.
FACILITACIÓN DESBLOQUEO MOTORES
Coloque el DIP11 en posición ON para habilitar la facilitación del desbloqueo manual (bajo
la condición de que el DIP10 esté en ON); una vez que el cierre se produjo, se ejecutará
una maniobra de inversión con un tiempo fijo de 0,2s para facilitar el desbloqueo manual.
FUNCIONAMIENTO DE LOS ACCESORIOS DE SEGURIDAD
FOTOCÉLULA (COM-PHOT)
DIP 4 OFF =>Con la cancela cerrada, si se interpone un obstáculo delante del rayo de las
fotocélulas, la cancela no abre. Durante el funcionamiento las fotocélulas
intervienen tanto en apertura (restableciendo el movimiento de apertura sólo
después de que las fotocélulas se liberan), como en cierre (restableciendo
el movimiento inverso sólo después de que las fotocélulas se liberan).
DIP 4 ON =>Con la cancela cerrada, si se interpone un obstáculo delante del rayo de las
fotocélulas y se ordena la apertura, la cancela se abre (durante la apertura
las fotocélulas no intervendrán). Las fotocélulas intervendrán solo en fase
de cierre (con restablecimiento del movimiento inverso después de un
segundo aún cuando las mismas estén ocupadas).
GESTIÓN DE CIERRE INMEDIATO DESPUÉS DEL TRÁNSITO POR LAS FOTOCÉLULAS
DIP16 ON y DIP4 OFF =>pasando por delante de las fotocélulas durante la apertura, la
cancela se detiene y sólo después de 1 segundo de que las
fotocélulas se liberan, la cancela se cierra.
DIP16 ON y DIP4 ON =>pasando por delante de las fotocélulas durante la apertura, la
cancela continúa abriéndose y cuando las fotocélulas se liberan,
la cancela se detiene y luego de 1 segundo de pausa invierte su
movimiento y comienza a cerrarse.
Si se alcanza la apertura completa (final del tiempo de apertura), se excluye el
cierre inmediato y se activa el tiempo de cierre automático (si el trimmer TCA está
habilitado y el led DL6 está encendido).
Si durante el cierre hay tránsito rápido (ej. peatonal) la cancela se volverá a abrir
por dos segundos para después volver a cerrarse nuevamente.
DIP12 OFF => cierre inmediato deshabilitado después del tránsito por las fotocélulas
NOTA: Si recomienda comprobar el funcionamiento de las fotocélulas al menos cada 6
meses.
EDGE (COSTA) (COM-EDGE)
Durante la apertura, si está ocupada, invierte el movimiento en cierre.
Durante el cierre, si está ocupada, invierte el movimiento en apertura.
Si permanece ocupada después de la primera actividad, ejecuta una ulterior inversión
después de 2 segundos, para después ejecutar una ulterior inversión pequeña y, entonces,
señalar la alarma de costa averiada u ocupada (contacto NO).
Si la costa permanece ocupada (contacto NO) cualquier movimiento es denegado.
Si no está utilizada, puentee los bornes COM-EDGE.
MONITORIZACIÓN COSTAS DE SEGURIDAD (A+TEST A-)
Mediante la entrada A+TEST y el DIP 12 ON es posible monitorizar la/s costa/s
La monitorización consiste en una Prueba Funcional de la costa, llevada a cabo al final de
cada apertura completa de la cancela.
Después de cada apertura, el cierre de la cancela, por consiguiente, se autoriza solo si la/s
costa/s han superado la Prueba Funcional.
ATENCIÓN: LA MONITORIZACIÓN DE LA ENTRADA COSTA PUEDE SER HABILITADA CON
EL DIP 12 EN ON, O DESHABILITADA CON EL DIP12 EN OFF. EN EFECTO, LA PRUEBA
FUNCIONAL DE LAS COSTAS ES POSIBLE SOLO EN EL CASO DE QUE SE TRATE DE
DISPOSITIVOS DOTADOS DE UN ALIMENTADOR DE CONTROL PROPRIO.
UNA COSTA MECÁNICA NO PUEDE SER MONITORIZADA, POR TANTO, EL DIP 12 DEBE
ESTAR COLOCADO EN POSICIÓN OFF.
ALARMA DE AUTOTEST COSTA (DIP 12 ON)
Al final de la apertura, si la monitorización de la costa dio resultado negativo, se acciona
una alarma identificada por el intermitente que permanece encendido; bajo esta condición,
el cierre de la cancela no está autorizado; solo reparando la costa y presionando uno de los
mandos habilitados es posible restablecer el normal funcionamiento.
PULSADOR DE STOP (COM-STOP)
Durante cualquier operación el pulsador de STOP ejecuta la detención de la
cancela.
Si se presiona con la cancela totalmente abierta (o parcialmente utilizando el mando
peatonal) se excluye temporalmente el cierre automático (si está habilitado mediante el
trimmer TCA y el led DL6 encendido) Por consiguiente, es necesario dar una nueva orden
para volverla a cerrar. En el ciclo sucesivo, la función de cierre automático es reactivada (si
habilitada mediante trimmer TCA y led DL6 encendido).
ALARMA SENSOR DE CORRIENTE
La central T2 24V está dotada de sensores automáticos que invierten la marcha de la
cancela en el caso de impactos contra cosas o personas de conformidad con las normas
EN vigentes (compruebe siempre con adecuado instrumento el respeto de los valores
configurados por la norma), sin tener que efectuar particulares regulaciones en la central, en
cuando gestionados por un software especial interno.
Si después de una primera intervención del sensor de corriente en apertura o cierre (solo
a alta velocidad) se tiene una segunda intervención, obviamente en sentido contrario, la
cancela se detiene y, entonces, invierte por 1 segundo.
El estado de alarma será visualizado por el intermitente que permanecerá activo durante
1 minuto. Durante este tiempo es posible restablecer el funcionamiento de la cancela
presionando cualquier pulsador de mando.
FUNCIONAMIENTO A HOMBRE PRESENTE EN CASO DE AVERÍAS CON LOS
ACCESORIOS DE SEGURIDAD
Si el burlete de seguridad está estropeado o se queda apretado por mas de 5 segundos, o,
si la fotocelula de seguridad se estropea o se queda empeñada por mas de 60 segundos, los
comandos ABRE, CIERRE, K BUTTON y el PEATONAL, funcionaràn solo a hombre presente.
El signal de activación de este funcionamiento serà indicado por el LED de programacion
que relampaguea.
En este funciòn, será aconsentido el apertura y el cierre solo manteniendo apretados los
pulsadores de comandos. El comando radio y el cierre automatico seràn excludidos porque
estas formas de funcionamientos no son permitidas por las normas.
Una vez que los accesorios de seguridad serán reparados o vuelven a funcionar
corectamente, despues de 1 segundo, en automatico, el comando paso paso y el automatico
pueden funcionar normalmente; por lo tanto sea el comando radio de los transmisores y el
cierre automatico pondràn funcionar como programado.
Nota 1: durante el funcionamiento a hombre presente, en caso de averìas con las costas
(o fotocelulas) las fotocelulas (o costas) trabajo mediante la interrupción de la
operación en curso.
Nota 2: El pulsador de stop no es considerado una seguridad que se puede bypasar en este
funcionamiento, y por lo tanto, si viene apretrado o se rompe, no permite algùn
movimiento del portón.
La maniobra a hombre presente es exclusivamente una maniobra de emergencia
56
E
S
y por lo tanto, se debe utilizar por un tiempo muy corto y con la seguridad visiva
sobre el movimiento del sistema. No apenas posible, se deberà que reparar los
accesorios de seguridad por un corecto funcionamiento.
INTERMITENTE
NOTA: Este cuadro electrónico puede alimentar SOLO INTERMITENTES CON CIRCUITO
INTERMITENTE (ACG7061) con lámparas de 24V y 20W máximo.
FUNCIÓN PRE-INTERMITENCIA
DIP5 - OFF => el motor y el intermitente arrancan contemporáneamente.
DIP5 - ON => el intermitente arranca 3 segundos antes que el motor.
INDICADOR DE SEÑALIZACIÓN DE CANCELA ABIERTA (COM-SIGNAL)
Cumple la función de señalizar los estados de cancela abierta, parcialmente abierta o no del
todo cerrada. Solo cuando la cancela está completamente cerrada se apaga.
Durante la programación, esta señalización está activa.
NOTA: Máx. 3 W. Si se excede con las botoneras o con las lámparas, la lógica del cuadro
electrónico resultará comprometida con posible bloqueo de las operaciones.
FUNCIONAMIENTO DESPUÉS DE UN APAGÓN (SIN BATERÍAS)
Cuando regresa la tensión de red, el led DL1 se encende y queda encendido para todo el
tiempo en que la puerta queda abierta. Se apagará una vez que la puerta llega en posición
de cierre completo.
Se recomienda abrir completamente la cancela. Deje que la cancela se cierre por sí sola
con el cierre automático o aguarde a que el intermitente deje de parpadear antes de dar
una orden de cierre.
Esta operación permitirá que la cancela se realinee. De hecho, si durante el apagón los
motores han sido desbloqueados y desplazados de su posición de cierre normal, la primer
maniobra, cuando vuelve la alimentación, debe ser completa.
Si el apagon ocurre cuando la puerta está en movimiento, o cuando la puerta está abierta, el
primer comando recibido serà el de cierre. El cierre de las dos hojas se hará con el desfase
total entre las dos hoja, y por lo tanto, primero serà el Motor 2 - M2 a cerrar. Una vez que
M2 se ha apagado, el Motor 1 - M1 cerrará. Este movimiento distinto de los dos motores
evitará la sopreposición de las 2 hojas.
CARACTERÍSTICAS TÉCNICAS
- Rango de temperatura
0 ÷ 55°C
- Humedad< 95 % sin condensación de aire
- Tensión de alimentación230 V~ ±10% (120V/60Hz a pedido)
- Frecuencia
50/60 Hz
- Alimentación batería
20-24 Vdc
- Potencia Transformador
130 VA
primario 230 Vac
secundario 18 Vac
- Absorsión máxima
50 mA
- Microinterrupciones de red
100 ms
- Potencia máxima indicador de cancela abierta24 Vdc 3 W (equivalente a 1 bombilla
de 3 W o 5 led con resistencia en
serie de 2,2 KΩ)
- Carga máxima intermitente
24 Vdc 20 W
- Corriente disponible para fotocélulas y accesorios 1A ±15%
200 mA
- Corriente disponibile en conector radio
CARACTERÍSTICAS TÉCNICAS RADIO (modelo T2 24V crx)
- Frecuencia Recepción
433,92 MHz
- Impedancia
52 Ω
- Sensibilidad
2-24 µV
- Tiempo excitación
300 ms
- Tiempo desexcitación
300 ms
- Todas las entradas deben ser utilizadas como contactos limpios porque la alimentación
se genera internamente (tensión segura) en la tarjeta y está dispuesta de modo tal que
garantice el respeto de aislación doble o reforzada respecto de las partes bajo tensión
peligrosa.
- Los posibles circuitos externos conectados a las salidas del cuadro electrónico deben
efectuarse de manera tal que garanticen el aislamiento doble o reforzado respecto de las
partes bajo tensión peligrosa.
- Todas las entradas son gestionadas por un circuito integrado programado que ejecuta un
autocontrol en cada puesta en marcha.
RESOLUCIÓN DE PROBLEMAS
Después de haber efectuado todas las conexiones siguiendo atentamente el esquema y
haber posicionado el portón en posición intermedia, verifique el correcto encendido de los
led rojos DL7, DL8 y DL9.
En caso de falta de encendido de los led, siempre con el portón en posición intermedia,
verifique lo que sigue y sustituya eventuales componentes averiados.
DL7 apagado Fotocélulas averiadas
DL8apagado
Borde de seguridad averiado (En caso que el borde no este conectado,
realice el puente entre COM y EDGE)
Pulsador de Stop averiado (en caso de que el Stop no esté conectado,
DL9apagado
realice un puente entre COM y STOP)
Durante el funcionamiento con hombre presente, con DIP N° 1 en ON, verifique que durante
la apertura de M1 y M2 se enciendan los led verdes DL2 y DL4 y que durante el cierre de
M1 y M2 se enciendan los led rojos DL3 y DL5.
De lo contrario, invierta los cables del motor interesado.
DEFECTO
SOLUCIÓN
Verifique la integridad de los fusibles F1, FUSE 1
Después de haber efectuado varias conexiones y haber dado tensión, todos los led están En caso de fusible interrumpido, utilice únicamente uno de valor adecuado.
apagados.
F1 T 2AFUSIBLE DE PROTECCIÓN TRANSFORMADOR (externo a la tarjeta T2 24V)
FUSE 1 8A FUSIBLE DE PROTECCIÓN DE MOTORES
El motor abre y cierra, pero no tiene fuerza y se mueve lentamente.
Verifique regulación trimmers RUN y LOW-SPEED.
El portón ejecuta la apertura, pero no cierra después del tiempo configurado.
Asegúrese de que el trimmer TCA esté habilitado con el led DL6 encendido.
Pulsador OPEN siempre activo, sustituya el pulsador o el switch del mando OPEN
Autotest de la costa fallido, verifique las conexiones entre el cuadro electrónico y el
alimentador para las costas. Atención: si no se está ultilizando un alimentador para las
costas, el DIP 12 debe estar colocado en posición OFF.
El portón no abre y no cierra accionando los pulsadores K, Radio, Open y Close.
Contacto costa de seguridad averiado. Contacto fotocélulas averiado con DIP 4 OFF. Arregle
o sustituya el correspondiente contacto.
El cierre eléctrico no funciona.
Asegúrese de haber habilitado el DIP 8 en ON.
El led DL1 parpadea rápidamente y no se habilita ningún movimiento.
Coloque los dip switch 1,2 o 3 en posición OFF.
57
E
S
OPCIONALES
Para las conexiones y datos técnicos de los accesorios, consultar los manuales respectivos.
PALANCA LARGA
CAJA FUERTE STONE
PALANCA LARGA para cancelas con pivote distante hasta 50 cm del borde de la columna.
cód. ACG8034
Contenedor de seguridad para impedir el acceso a los dispositivos de mando. Se entrega
con una serie completa de pulsadores de báscula (abre-cierra) y desbloqueo. Necesita
del cable ACG8022.
En aluminio fundido a presión - IP54
cód. ACJ9078
CAJA FUERTE FLAT
CABLE PARA DESBLOQUEO
Contenedor de seguridad para impedir el acceso a los dispositivos de mando. Se entrega
con una serie completa de pulsadores de báscula (abre-cierra) y desbloqueo. Necesita
del cable ACG8022.
En aluminio fundido a presión - IP54
cód. ACJ9071
Cable para desbloqueo desde el exterior para conectar a la caja fuerte. cód. ACG8022
CERRADURA ELÉCTRICA
Cerradura Horizontal - izquierda vista externa - 12Vac
Serratura Verticale - 12Vac
Cerradura Vertical - 12Vac
BATERÍA
cód. ACG8670
cód. ACG8650
cód. ACG8650
Batería 2,2Ah 12V
cód. ACG9515
T2 24V Wi-Fi
Cuadro con sensores de impacto y tarjeta MASTER Wi-Fi.
Con contenedor.
cód. ABT2025W
58
TARJETA DE CARGA BATERÍA
cód. ACG4661
®
automatismi per cancelli
automatic entry systems
R.I.B. S.r.l.
25014 Castenedolo - Brescia - Italy
Via Matteotti, 162
Tel. ++39.030.2135811
Fax ++39.030.21358279 - 21358278
www.ribind.it - [email protected]
AZIENDA CON SISTEMA
DI QUALITÀ CERTIFICATO
DA DNV
COMPANY WITH QUALITY
SYSTEM CERTIFIED
BY DNV
DICHIARAZIONE DI CONFORMITÁ - DECLARATION OF COMPLIANCE
DÉCLARATION DE CONFORMITÉ - ÜBEREINSTIMMNUGSERKLÄRUNG
DECLARACIÓN DE CONFORMIDAD
Dichiariamo sotto la nostra responsabilità che l’operatore PREMIER 24V è conforme alle seguenti norme e Direttive:
L’opérateur PREMIER 24V se conforme aux normes suivantes:
We declare under our responsibility that PREMIER 24V operator is conform to the following standards:
Wir erklaeren das der PREMIER 24V den folgenden EN-Normen entspricht:
Declaramos bajo nuestra responsabilidad que los operators PREMIER 24V es conforme a la siguientes normas y disposiciones:
EN 301 489-1
2011
EN 55014-2
2015
EN 61000-6-1
2007
EN 301 489-3
2013
EN 60335-1
2016
EN 61000-6-2
2006
EN 300 220-1
2012
EN 60335-2-103 2010
EN 61000-6-3
2013
EN 300 220-3
2010
EN 61000-3-2
2015
EN 61000-6-4
2013
EN 55014-1
2012
EN 61000-3-3
2014
Inoltre permette un’installazione a Norme - Permit, en plus, une installation selon les normes suivants
You can also install according to the following rules - Desweiteren genehmigt es eine Installation der folgenden Normen:
Además permite una instalación según las Normas:
EN 12453
2002
EN 12445
2002
EN 13241-1
2011
Come richiesto dalle seguenti Direttive - Conformément aux Directives
As is provided by the following Directives - Wie es die folgenden Richtlinien verfügen
Tal y como requerido por las siguientes Disposiciones:
2006/95/CE
2004/108/CE
1999/5/EC
Il presente prodotto non può funzionare in modo indipendente ed è destinato ad essere incorporato in un impianto costituito da ulteriori elementi. Rientra perciò nell’Art. 6 paragrafo 2 della
Direttiva 2006/42/CE (Macchine) e successive modifiche, per cui segnaliamo il divieto di messa in servizio prima che l’impianto sia stato dichiarato conforme alle disposizioni della Direttiva.
Le présent dispositif ne peut fonctionner de manière indépendante, étant prévu pour être intégré à une installation constituée d’autres éléments. Aussi rentre-t-il dans le champ d’application
de l’art. 6, paragraphe 2 de la Directive machines 2006/42/CEE et de ses modifications successives. Sa mise en service est interdite avant que l’installation ait été déclarée conforme
aux dispositions prévues par la Directive.
This product can not work alone and was designed to be fitted into a system made up of various other elements. Hence, it falls within Article 6, Paragraph 2 of the EC-Directive 2006/42
(Machines) and following modifications, to which respect we point out the ban on its putting into service before being found compliant with what is provided by the Directive.
Dieses Produkt kann nicht allein funktionieren und wurde konstruiert, um in einen von anderen Bestandteilen zusammengesetzten System eingebaut zu werden. Das Produkt fällt deswegen
unter Artikel 6, Paragraph 2 der EWG-Richtlinie 2006/42 (Maschinen) und folgenden.
Este producto no puede funcionar de manera independiente y se tiene que incorporar en una instalación compuesta por otros elementos. Está incluido por lo tanto en el Art. 6 párrafo 2
de la Disposición 2006/42/CEE (Maquinaria) y sus siguientes modificaciones, por lo cual destacamos que está prohibido poner la instalación en marcha antes de que esté declarada
conforme a la citada Disposición.
Legal Representative
(Rasconi Antonio)
59
KIT PREMIER 24V
AC07089
DRD5
CPL1252
DTB55X16
DAC39X95
DAC29X19
CEL1522
CEL1557
CEL1427
DAC42X13
CAL1174
CPL1258
DAC29X95
CAL1175
CCM6201
BA10093
BA01550
DRL4X10Z
DAC35X95
DAS42X13
DUK6004ZZ
CTC1110
CCA1522
CFS1014
CME1141
CTC1013
CCM6201
CTC1294
CME1139
CTC1298
CFS1016
CEL1428
DAC4X10
CME1137
DRD4
DTB8X100I
CTC1149
CCA1523
DAS35X95I
DAE63X40
DRL66X18I
CME1138
CPL1326
CPL1323
CCM6205
CAL1176
CEL1556
CAL1172
DTB6X20I
CAL1173
CAL1189
CPL1325
DAS42X13
DDD8MAI
DAS29X95
CPL1254
CEL1545
CPL1327
ACG8022
Cavo c/guaina Premier
ACG8023
CVA1912
GRUPPO LEVE DI TRAINO
CME2153
CTC1107
CCA1352
DRL10X26
DRG6I
DRG10
DTC6X10I
DTE10X25Z
CVA1847
CCA1353
CCA1355
DSC6X20I
DRL10X20I
DRL8X17I
DDD8MAI
Denominazione Particolare
SCHEDA T2 24V CRX
PERNO CON ATTACCO CANC. PREMIER
MOTORIDUT. PREMIER 24VCC S/ENC.
CARTER PREMIER CON TAPPI
SERIE ACCESS. CILIND. PREMIER
LEVA ATTACCO CANCELLO PREMIER
FERMO MECCANICO DESTRO PREMIER
LEVA ALBERO PREMIER
COPERCHIO SUPP. CUSC. PREMIER
SUPPORTO CUSCINETTI PREMIER
CARTER INFERIORE PREMIER
FERMO MECCANICO SINISTRO PREMIER
PIASTRA GINOCCHIA 1
PIASTRA GINOCCHIA 2
LEVA SBLOCCO PREMIER
PIASTRA FISS COLONNA PREMIER
CUSC. MOT. 6201ZZ
CUSC. MOT. 6205ZZ 25 52 15
FUSIBILE 5X20 1,6A RITARDATO
CAP.OCCH.5055 T OT STAG.CRIMP.
SUPP. SELLA X FASCETTE ELEM 5498
MORSETTO PORTAF. OK133/2 (4201262)
TRASF.TOR.130VA P230-S18 COMET S
PASSACAVO GOMMA D=29 GW 50 430
CAVO PROLUNGA CAVO MOTORE
CFS1014
CFS1016
CME1137
CME1138
CME1139
CME1141
CPL1252
CPL1253
CPL1258
CPL1323
CPL1325
CPL1326
CPL1327
CTC1013
CTC1107
CTC1110
CTC1149
CTC1154
CTC1259
CTC1294
CTC1298
CVA1847
CVA1912
DAC29X22
DAC29X95
DAC35X95
CAMMA SBLOCCO PREMIER
INGRANAGGIO SBLOCCO PREMIER
PERNO SBLOCCO PREMIER
ALBERO LENTO PREMIER
VITE RULLATA PREMIER
INGRANAGGIO ELIC. PREMIER
PORTA SCHEDA PREMIER
COPRI LEVA PREMIER
FERMO LEVETTA SBLOCCO PREMIER
CHIAVE TRIANG.SBL.MAGIC
PROFILI DI SICUREZZA PREMIER
COPERCHIO COPRI TRASF.PREMIER
CUSTODIA TRASFORMATORE PREMIER
CHIAVETTA 8 7 25
PARAOLIO 25 47 7
PARAOLIO 12 24 7
SPESSORE 12 18 1
SPINA ELASTICA 4 20
MOLLA TRAZ. COPERC.KING/K
MOLLA SBLOCCO PREMIER
CHIAVETTA FORATA 6 6 30
BOCCOLA BRONZO INT.D=8 EST.D=12
PERNO M8 PREMIER 24V
VITE AUT.TC.CR. 2,9X2,2
VITE AUT.TC.CR. 2,9X9,5 DIN 798
VITE AUT.TC.CR. 3.5X9.5
DDD6MAI
CAL1171
DAC39X95
DAC42X13
DAE63X40
DAS29X13
DAS35X95I
DAS42X13
DDD6MAI
DDD8MAI
DRD4
DRG6I
DRG10
DRL10X30Z
DRL4X10Z
DRL10X26
DRL66X18I
DRL8X24I
DSC6X20I
DTB55X16
DTB6X20I
DTB8X100I
DTC5X10Z
DTC6X10I
DTE10X25Z
DTE8X30I
DUK6004ZZ
VITE AUT.TC.CR. 3.9X9.5 DIN798
VITE AUT.TC.CR. 4,2X13
VITE AUT.TE. 6,3X40 UNI 7323/3
VITE AUT.TS.CR. 2.9X13 DIN 798
VITE AUT.TS.CR. 3.5X9.5
VITE AUT.TS.CR. 4,2X13 DIN7982
DADO AUTOB. 6MA INOX
DADO AUTOB. 8MA INOX
ROND.DENT. D=4 PIANA ZINC DIN 6798
ROND.GROVER D=6 INOX
ROND.GROVER D=10
ROND. PIANA 10X30 ZINCATA
ROND. PIANA 4X09 ZINCATE
ROND. PIANA 10,5X26X2,5
* ROND. PIANA 6,6X18X2 ZINCATA
ROND. PIANA 8X24 INOX
VITE TSP.CR. 6X20 INOX
VITE TCEI 5,5X16 AUTOF. ZINC.
VITE TCEI 6X20 INOX
VITE TCEI 8X100 INOX 5931
VITE TC.CR. 5X10 UNI 7687
VITE TC.CR. 6X10 INOX 7687
VITE TE 10X25 UNI 5739
VITE TE 8X30 INOX UNI 5739
CUSC. 6004ZZ (20x42x12)
Questo prodotto è stato completamente progettato e costruito in Italia · Ce produit a été complètement développé et fabriqué en Italie · This product has been
completely developed and built in Italy · Dieses Produkt wurde komplett in Italien entwickelt und hergestellt · Artìculo totalmente proyectado y producido en Italia
®
automatismi per cancelli
automatic entry systems
25014 CASTENEDOLO (BS) - ITALY
Via Matteotti, 162
Tel. +39.030.2135811
Fax +39.030.21358279
www.ribind.it - [email protected]
Cod. CVA1995 - 26052016 - Rev. 15
CPL1253
Codice
AC07089
BA01087
BA10093
BA01511
BA01550
CAL1171
CAL1172
CAL1173
CAL1174
CAL1175
CAL1176
CAL1189
CCA1352
CCA1353
CCA1522
CCA1523
CCM6201
CCM6205
CEL1427
CEL1428
CEL1520
CEL1522
CEL1545
CEL1556
CEL1557
BA01511
CEL1520
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertisement