T2 24V
KIT KING 24V
con / avec / with / mit
T2 24V
KIT KING 24V
KIT KING 24V Wi-Fi
Operatore
Operateur
Operator
Torantrieb
Operador
Alimentazione
Alimentation
Power Supply
Stromspannung
Alimentacion
Peso max cancello
Poids maxi portail
Max gate weight
Max Torgewicht
Peso máx verja
Forza max di spinta
Force maxi de poussée
Thrust force
Max. Schubkraft
Fuerza max de empuje
24Vdc
400 kg / 880 lbs
N 1800
KIT KING 24V
Codice
Code
Code
Code
Codigo
AD00709
KIT KING 24V Wi-Fi
AD00716
ITALIANO pag. 05 / FRANÇAIS pag. 16 / ENGLISH page 27 / DEUTSCH pag. 38 / ESPAÑOL pag. 49
1
I
F
ISTRUZIONI DI SICUREZZA IMPORTANTI PER
L’INSTALLAZIONE
ATTENZIONE - PER LA SICUREZZA DELLE PERSONE È IMPORTANTE CHE
VENGANO SEGUITE TUTTE LE ISTRUZIONI
CONSERVARE CON CURA QUESTE ISTRUZIONI
1° -Se non è previsto nel quadro elettronico, installare a monte del medesimo
un’interruttore di tipo magnetotermico (onnipolare con apertura minima dei
contatti pari a 3 mm) che riporti un marchio di conformità alle normative
internazionali. Tale dispositivo deve essere protetto contro la richiusura
accidentale (ad esempio installandolo entro quadro chiuso a chiave).
2° -Per la sezione ed il tipo dei cavi la RIB consiglia di utilizzare un cavo di tipo
H05RN-F con sezione minima di 1,5 mm2 e comunque di attenersi alla norma
IEC 364 e alle norme di installazione vigenti nel proprio Paese.
3° -Posizionamento di un’eventuale coppia di fotocellule: il raggio delle fotocellule
deve essere ad un’altezza non superiore a 70 cm dal suolo e ad una distanza
dal piano di movimento della porta non superiore a 20 cm. Il loro corretto
funzionamento deve essere verificato a fine installazione in accordo al punto
7.2.1 della EN 12445.
4° -Per il soddisfacimento dei limiti imposti dalla EN 12453, se la forza di picco
supera il limite normativo di 400 N è necessario ricorrere alla rilevazione di
presenza attiva sull’intera altezza della porta (fino a 2,5 m max). Le fotocellule
in questo caso sono da applicare come indicato nella norma EN 12445 punto
7.3.2.2).
N.B.: È obbligatoria la messa a terra dell’impianto.
I dati descritti nel presente manuale sono puramente indicativi.
RIB si riserva di modificarli in qualsiasi momento.
Realizzare l’impianto in ottemperanza alle norme ed alle leggi vigenti.
INSTRUCTIONS DE SECURITE IMPORTANTES POUR
L’INSTALLATION
ATTENTION - POUR LA SECURITE DES PERSONNES, IL EST IMPORTANT DE
SUIVRE TOUTES LES INSTRUCTIONS
CONSERVER SOIGNEUSEMENT CES INSTRUCTIONS
1° -Si ce n’est pas prévu dans la centrale, installer en amont de celle-ci un interrupteur
de type magnétothermique (omnipolaire avec ouverture minimum des contacts de 3
mm) qui porte une marque de conformité aux normes internationales. Ce dispositif
doit être protégé contre la re-fermeture accidentelle (par exemple en l’installant
dans un tableau fermé à clé).
2° -En ce qui concerne la section et le type des câbles, RIB conseille d’utiliser un câble
de type H05RN-F ayant une section minumum de 1,5 mm2 et de toute façon, s’en
tenir à la norme IEC 364 et aux normes d’installation en vigueur dans le propre pays.
3° -Positionnement d’un couple éventuel de photocellules: Le rayon des photocellules
doit se situer à une hauteur qui ne doit pas être supérieure à 70 cm du sol et à
une distance du plan de mouvement de la porte qui ne doit pas être supérieure à
20 cm. Leur bon fonctionnement doit être vérifié en fin d’installation selon le point
7.2.1 de la EN 12445.
4° -Pour satisfaire aux limites imposées par la EN 12453, si la force de pointe dépasse
la limite de la norme de 400 N, il est nécessaire de recourir au relevé de présence
active sur la hauteur totale de la porte (jusqu’à 2,5 m max). - Les photocellules,
dans ce cas, doivent être appliquées selon le point 7.3.2.2 de la EN 12445
N.B.: La prise de terre sur l’installation est obligatoire.
Les données décrites dans ce manuel sont purement indicatives.
RIB se réserve le droit de les modifier à tout moment.
Réaliser l’installation en conformité aux normes et aux lois en vigueur.
INSTRUCTIONS IMPORTANTES DE SECURITE POUR L’INSTALLATION
ATTENTION - UNE INSTALLATION NON CORRECTE PEUT CAUSER DE GRAVES
DOMMAGES
SUIVRE TOUTES LES INSTRUCTIONS D’INSTALLATION
1° -Ce livret d’instructions est adressé exclusivement à un personnel spécialisé
qui connaît les critères de construction et les dispositifs de protection contre les
accidents concernant les portails, les portes et les portes cochères motorisés (s’en
tenir aux normes et aux lois en vigueur).
2° -L’installateur devra délivrer à l’utilisateur final un livret d’instruction en accord à la
EN 12635.
3° -L’installateur avant de procéder à l’installation, doit prévoir l’analyse des risques
de la fermeture automatisée finale et la mise en sécurité des points identifiés
dangereux (en suivant les normes EN 12453/EN 12445).
4° -L’installateur, avant d’installer le moteur de mouvement, doit vérifier que le
portail de fer soit en bonnes conditions mécaniques et qu’il s’ouvre et se ferme
correctement.
5° -L’installateur devra installer l’organe pour l’exécution de la relâche manuelle à une
hauteur inférieure à 1,8 m.
6° -L’installateur devra retirer d’éventuels obstacles au mouvement motorisé du portail
de fer (ex. verrous, serrures, etc).
7° - L’installateur devra appliquer, de façon permanente, les étiquettes qui mettent
en garde contre l’écrasement, dans un endroit bien visible ou à proximité de
commandes fixes éventuelles.
8° - Le câblage des divers composants électriques externes à l’opérateur (par exemple
photocellules, clignotants, etc) doit être effectué selon la EN 60204-1 et les
modifications apportées à celle-ci dans le point 5.2.2 de la EN 12453.
9° - Le montage éventuel d’un tableau pour la commande manuelle du mouvement doit
être fait en positionnant le tableau de façon à ce que la personne qui l’actionne ne
se trouve pas en position de danger; de plus, il faudra faire en sorte que le risque
d’actionnement accidentel des boutons soit réduit.
10° - Tenir les commandes de l’automatisme (tableau, télécommande, etc) hors de portée
des enfants. L’organe de manoeuvre (un interrupteur tenu fermé manuellement)
doit être dans une position qui soit visible de la partie guidée mais lointaine des
parties en mouvement. Il doit être installé à une hauteur moindre de 1,5 m.
11° - Cet appareil peut être utilisé par des enfants âgés de 8 ans et plus et les personnes
dont les capacités physiques, sensorielles ou mentales réduites, ou manquant
d’expérience et de connaissances si elles sont sans surveillance ou instruction
concernant l’utilisation de l’équipement en toute sécurité et de comprendre les
risques encourus.
12° - Enfants ne doivent pas jouer avec l’appareil.
13° - Nettoyage et entretien utilisateur n’a pas à être effectué par des enfants sans
surveillance.
14° - Ne laissez pas les enfants jouer avec les commandes fixes. Gardez la télécommande
hors de portée des enfants.
15° - Les dispositifs fixes de commande doivent être installés de sorte qu’ils soient
visibles.
16° - Avant l’exécution de toute opération d’installation, de réglage, d’entretien de
l’installation, couper le courant en agissant sur l’interrupteur magnétothermique à
cet effet, branché en amont de l’installation.
17° - A la fin de l’installation, l’installateur devra s’assurer que les parties de la porte
n’encombrent pas la rue ou le trottoir public.
LA SOCIETE RIB N’ACCEPTE AUCUNE RESPONSABILITE pour d’éventuels
dommages provoqués par la non-observation dans l’installation, des normes de
sécurité et des lois actuellement en vigueur.
ISTRUZIONI IMPORTANTI DI SICUREZZA PER L’INSTALLAZIONE
ATTENZIONE - L’INSTALLAZIONE NON CORRETTA PUÒ CAUSARE GRAVI DANNI
SEGUIRE TUTTE LE ISTRUZIONI DI INSTALLAZIONE
1° -Questo libretto d’istruzioni è rivolto esclusivamente a del personale
specializzato che sia a conoscenza dei criteri costruttivi e dei dispositivi di
protezione contro gli infortuni per i cancelli, le porte e i portoni motorizzati
(attenersi alle norme e alle leggi vigenti).
2° -L’installatore dovrà rilasciare all’utente finale un libretto di istruzioni in accordo
alla 12635.
3° -L’installatore prima di procedere con l’installazione deve prevedere l’analisi
dei rischi della chiusura automatizzata finale e la messa in sicurezza dei punti
pericolosi identificati (seguendo le norme EN 12453 / EN 12445).
4° -L’installatore prima di installare il motore di movimentazione deve verificare
che il cancello sia in buone condizioni meccaniche e che si apra e chiuda
adeguatamente.
5° -L’installatore dovrà installare l’organo per l’attuazione del rilascio manuale ad
un’altezza inferiore a 1,8 m.
6° -L’installatore dovrà rimuovere eventuali impedimenti al movimento motorizzato
del cancello (es. chiavistelli, catenacci, serrature ecc.)
7° -L’installatore dovrà applicare in modo permanente le etichette che mettono in
guardia contro lo schiacciamento in un punto molto visibile o in prossimità di
eventuali comandi fissi.
8° -Il cablaggio dei vari componenti elettrici esterni all’operatore (ad esempio
fotocellule, lampeggianti, ecc.) deve essere effettuato secondo la EN 60204-1
e le modifiche a questa apportate dal punto 5.2.2 della EN 12453.
9° -
L’eventuale montaggio di una pulsantiera per il comando manuale del
movimento deve essere fatto posizionando la pulsantiera in modo che chi la
aziona non si trovi in posizione pericolosa; inoltre si dovrà fare in modo che sia
ridotto il rischio di azionamento accidentale dei pulsanti.
10° -
Tenete i comandi dell’automatismo (pulsantiera, telecomando etc) fuori
dalla portata dei bambini. L’organo di manovra (un interruttore tenuto
chiuso manualmente) deve essere in una posizione che sia visibile dalla parte
guidata ma lontana dalle parti in movimento. Deve essere installato a un’altezza
minima di 1,5 m.
11° -Questo apparecchio può essere utilizzato da bambini di età compresa dagli 8
anni e al di sopra e le persone con ridotte capacità fisiche, sensoriali o mentali,
o mancanza di esperienza e conoscenza se sono stati controllati o istruiti all’uso
dell’apparecchio in modo sicuro e capire i rischi connessi.
12° -I bambini non devono giocare con l’apparecchio.
13° -
Pulizia e manutenzione utente non deve essere fatta da bambini senza
supervisione.
14° -Non permettere ai bambini di giocare con i comandi fissi. Tenere i telecomandi
lontano dai bambini.
15° -I dispositivi di comando fissi devono essere installati in modo che siano visibili.
16° -
Prima di eseguire qualsiasi operazione di installazione, regolazione,
manutenzione dell’impianto, togliere la tensione agendo sull’apposito
interruttore magnetotermico collegato a monte dello stesso.
17° -A fine installazione l’installatore dovrà assicurarsi che le parti della porta non
ingombrino strade o marciapiedi pubblici.
LA DITTA RIB NON ACCETTA NESSUNA RESPONSABILITÀ per eventuali
danni provocati dalla mancata osservanza nell’installazione delle norme di
sicurezza e delle leggi attualmente in vigore.
2
G
B
D
IMPORTANT SAFETY INSTRUCTIONS FOR THE
INSTALLATION
WICHTIGE SICHERHEITS ANLEITUNGEN FÜR DIE
INSTALLATIONEN
ATTENTION - FOR THE SAFETY OF PEOPLE IT IS IMPORTANT TO FOLLOW ALL
THE INSTRUCTIONS
KEEP THESE INSTRUCTIONS WITH CARE
1° - If it is not forecast in the electric gearcase, install a switch of magneto thermic
type upstream, (omni polar with minimum opening of the contacts of 3 mm) with a
check of conformity to the international standards. Such device must be protected
against the accidental lockup (for example by installing inside a locked board).
2° - For the section and the type of the cables RIB advices to use a cable of H05RN-F
type with 1,5 sqmm minimum section and, however, to keep to the IEC 364 and
installation standards in force in your country.
3° - Positioning of a possible couple of photoelectric cells: the radius of the
photoelectric cells must be at a height of no more than 70 cm from the ground
and at a distance not superior to 20 cm from the motion plane of the door. Their
correct working must be verified at the end of the installation in accordance with
the point 7.2.1 of the EN 12445
4° - To fulfill the limits set by EN 12453, and in case the peak force exceeds the
normative limit of 400 N it is necessary to have recourse to the active presence
survey on the whole height of the door (up to max 2,5 m) - The photoelectric cells,
in this case, must be applied in accordance with the point 7.3.2.2 of the EN 12445
N.B.: The earthing of the system is obligatory.
The data described in this handbook are purely a guide.
RIB reserves the right to change them in any moment.
Carry out the system in the respect of the standards and laws in force.
ACHTUNG - FÜR DIE SICHERHEIT DER PERSONEN IST ES WICHTIG, DASS ALLE
ANWEISUNGEN GENAU AUSGEFÜHRT WERDEN
INSTALLATIONSVORSCHRIFTEN BEACHTET WERDEN
1° - Wenn nicht bereits an der elektrischen Schaltzentrale vorgesehen, muss vor der
Schaltzentrale ein thermomagnetischer Schalter installiert werden (omnipolar, mit
einer minimalen Kontaktöffnung von 3 mm), der ein von den internationalen Normen
anerkanntes Konformitätszeichen besitzt. Solch ein Geraet muss vor Vandalismus
geschuetzt werden (z.B.mit einen Schluesselkatsten in einem Panzergehaeuse).
2° - RIB empfiehlt den Kabeltyp H05RN-F mit einem minimalen Querschnitt von 1,5 mm2
generell sollten die Normative IEC 364 und alle anderen geltenden Montagenormen
des Bestimmungslandes eingehalten werden.
3° - Position des ersten paar Fotozellen: Der sollten nicht hoeher als 70 cm vom Boden
sein, und sollte nicht mehr als 20 cm entfernt von der Achse des Tores sitzen (das
gilt fuer Schiebe und Drehtore). In Übereinstimmung mit dem Punkt 7.2.1 der EN
12445 Norm, ihr korrektes Funktionieren muß einmal überprüft werden.
4° - In Einklang mit der Norm EN12453, ist es bei Toren notwendig eine komplette
Sicherheitslieiste zu installieren, bei denen mehr als 400 N Kraft aufgewand werden
muessen, um das Tor zum anhalten zu bringen (Maximum von 2,5 m anwenden) Die Fotozellen müssen in diesem Fall sein beantragen außen zwischen EN 12445
Punkt 7.3.2.2).
ANMERKUNG: Die Erdung der Anlage ist obligatorisch
Die in diesem Handbuch aufgeführten Daten sind ausschließlich empfohlene Werte. RIB
behält sich das Recht vor, das Produkt zu jedem Zeitpunkt zu modifizieren. Die Anlage
muss in Übereinstimmung mit den gültigen Normen und Gesetzen montiert werden.
IMPORTANT SAFETY INSTRUCTIONS FOR THE INSTALLATION
ATTENTION - THE INCORRECT INSTALLATION CAN CAUSE SERIOUS DAMAGES
FOLLOW ALL INSTALLATION INSTRUCTIONS
1° -This handbook is exclusively addressed to the specialized personnel who
knows the constructive criteria and the protection devices against accidents for
motorized gates, doors and main doors (follow the standards and the laws in
force).
2° -The installer will have to issue a handbook to the final user in accordance with
the 12635.
3° -Before proceeding with the installation, the installer must forecast the risks
analysis of the final automatized closing and the safety of the identified
dangerous points (Following the standards EN 12453/EN 12445).
4° -Before installing the motion motor, the installer must verify that the gate is in
good mechanical conditions and that it adequately opens and closes.
5° -The installer must install the member for the manual release at a height inferior
to 1,8 m.
6° -The installer will have to remove possible impediments to the motorized motion
of the gate (eg. door bolts, sliding bolts, door locks etc.)
7° -The installer will permanently have to put the tags warning against the deflection
on a very visible point or near possible fixed controls.
8° -The wiring harness of the different electric components external to the operator
(for example photoelectric cells, flashlights etc.) must be carried out according
to the EN 60204-1 and the modifications to it done in the point 5.2.2 of the EN
12453.
9° -The possible assembly of a keyboard for the manual control of the movement
must be done by positioning the keyboard so that the person operating it
does not find himself in a dangerous position; moreover, the risk of accidental
activation of the buttons must be reduced.
10° -Keep the automatism controls (push-button panel, remote control etc.) out of
the children way. Command device for operating the motor (a switch manually
closed) should be placed in area visible from the guided site and far from moving
parts. It should be placed at least at 1,5 m height.
11° -this appliance can be used by children aged from 8 years and above and persons
with reduced physical, sensory or mental capabilities or lack of experience and
knowledge if they have been given supervision or instruction concerning use of
the appliance in a safe way and understand the hazards involved
12° -children shall not play with the appliance
13° -cleaning and user maintenance shall not be made by children without supervision
14° -do not allow children to play with fixed controls. Keep remote controls away from
children
15° -Fixed command devices should be installed in a well visible way.
16° -Before carrying out any installation, regulation or maintenance operation of the
system, take off the voltage by operating on the special magneto thermic switch
connected upstream.
17° -At the end of the installation, the installer will have to make sure that the parts
of the door do not encumber streets or public sidewalks.
WICHTIGE SICHERHEITS ANLEITUNGEN FÜR DIE INSTALLATIONEN
WARNUNG - UNSACHGEMÄSSE INSTALLATION KANN ZU SCHWEREN
VERLETZUNGEN
ALLE INSTALLATIONSANLEITUNGEN BEFOLGEN
1° - Diese Betriebsanleitung dient ausschließlich dem Fachpersonal, welche
die Konstruktionskriterien und die Sicherheits-Vorschriften gegen Unfälle für Tore,
Türen und automatische Tore kennt (geltende Normen und Gesetze beachten
und befolgen).
2° - Der Monteur muss dem Endkunde eine Betriebsanleitung in Übereinkunft der
EN12635 überreichen.
3° - Vor der Installierung muss für die automatische Schließung und zur
Sicherheitsgewährung der identifizierten kritischen Punkte, eine Risiko Analyse
vorgenommen werden mit der entsprechenden Behebung der identifizierten,
gefährlichen Punkte. (die Normen EN 12453/EN 12445 befolgend).
4° -Vor den Bewegungsmotor zu installieren, ist es nötig die mechanischen Zustande
von der Gittertür (Öffnung, Schluss, u.s.w.) zu prüfen.
5° -Das Element für den manuellen Schiebebetrieb muss bei einer geringeren Höhe
von 1,80 Metern installiert sein.
6° -Der Installateur muss mögliche Verhinderungen an der Gittertürbewegung (wie
z.B. Riegeln, Schlossen u.s.w.) abnehmen.
7° -Der Installateur muss ständige Etiketten, gegen die Zerdrücken Gefahr, auf einen
sehr sichtbaren Punkt oder in der nähe von stationären Steuerungen anbringen.
8° -Die Verkabelung der verschiedenen externen elektrischen Komponenten zum
Operator (z.B. Fotozellen, Blinker etc.) muss nach EN 60204-1 ausgeführt
werden, Änderungen davon nach Punkt 5.2.2 der EN 12453.
9° -Die eventuelle Montage einer Schalttafel für den manuellen Bewegungsbefehl
muss so angebracht werden, dass der Benutzer sich nicht in einer Gefahrenzone
befindet, und dass, das Risiko einer zufälligen nicht gewollten Aktivierung von
Schaltern gering ist.
10° -
Alle Steuerungselemente (Schalttafel, Fernbedienung etc.) gehören nicht in
Reichweite von Kindern. Das Schalten Element (einen Schalter dass manuell
geschlossen ist) muss sichtbar aus dem angetriebenen Teil sein, und muss
entfernt aus dem beweglichen Teil sein. Dies Element muss bei einer Höhe von
wenigsten 1,50 Metern installiert sein.
11° -Die Nutzung von diesem Gerät ist erlaubt an Kinder ab 8 Jahre alte. Es ist
nötig die Personen mit physischen und Intellekt Handikapen, auf die möglichen
Gefahren zu warnen.
12° -Die Kinder muss mit diesem Gerät nicht spielen.
13° -Die Kinder muss die Reinigung und die Wartung von diesem Gerät, ohne Aufsicht,
nicht machen.
14° -Die Kinder muss mit den Steuerungen und mit den Fernsteuerungen nicht
spielen.
15° -Die fixe Steuerungen muss sichtbare nach der Installation sein.
16° -Vor jeglichem Eingriff, sei es Installation, Regulation oder Wartung der Anlage,
muss vorher die Stromzufuhr unterbrochen werden, den dafür bestimmten
Magnetthermo-Schalter drücken, der am Eingang der Anlage installiert ist.
17° -Nach der Installation ist es nötig zu prüfen dass Teile von der Gittertür keinen
Hindernis auf Straße oder Bürgersteige verursachen.
DIE FIRMA RIB ÜBERNIMMT KEINE VERANTWORTUNG für eventuelle Schäden,
die entstehen können, wenn die Installierungsvorschriften die den gültigen
Sicherheitsnormen entsprechen, nicht eingehalten werden.
THE RIB COMPANY DOES NOT ACCEPT ANY RESPONSIBILITY for possible
damages caused by the non observance during the installation of the safety
standards and of the laws in force at present.
3
E
S
IMPORTANTES INSTRUCCIONES DE SEGURIDAD PARA
LA INSTALACIÓN
ATENCIÓN PARA LA SEGURIDAD DE LAS PERSONAS ES IMPORTANTE QUE SE
OBSERVEN TODAS LAS INSTRUCCIONES
CONSERVAR CUIDADOSAMENTE ESTAS INSTRUCCIONES
1° -En el caso de que no sea previsto en la central eléctrica, instalar antes de la
misma, un interruptor de tipo magnetotérmico (omnipolar con una apertura
mínima de los contactos de 3 mm) que dé un sello de conformidad con las
normas internacionales. Este dispositivo tiene que estar protegido contro cierres
accidentales (por ejemplo instalándolo dentro de un panel cerrado a llave).
2° -Para la sección y el tipo de los cables, RIB aconseja utilizar cables de tipo H05RN-F
con sección mínima de 1,5 mm2 e igualmente atenerse a la norma IEC 364 y a las
normas de instalación del propio país.
3° -Posicionamiento eventual de un par de fotocélulas. El rayo de las fotocélulas
no debe estar a más de 70 cm de altura desde el suelo y a una distancia de
la superficie de movimiento de la puerta, no superior a 20 cm. El correcto
funcionamiento tiene que ser controlado al final de la instalación de acuerdo con el
punto 7.2.1 de la EN 12445.
4° -Para lograr satisfascer los límites impuestos por la EN 12453, si la fuerza de punta
supera el límite normativo de 400 N, es necesario recurrir al control de presencia
activa en toda la altura de la puerta (hasta a 2,5m max). - Las fotocélulas en este
caso se deben colocar como indicado en la EN 12445 punto 7.3.2.2.
PS.: Es obligatorio la puesta a tierra del sistema.
Los datos descritos en el presente manual son sólamente indicativos.
RIB se reserva de modificarlos en cualquier momento.
Realizar el sistema respetando las normas y las leyes vigentes.
IMPORTANTES INSTRUCCIONES DE SEGURIDAD PARA LA INSTALACIÓN
CUIDADO: UNA INCORRECTA INSTALACIÓN PUEDE CAUSAR GRAVES DAÑOS
SEGUIR TODAS LAS INSTRUCCIONES DE INSTALACIÓN
1° -Este manual de instrucciones está exclusivamente dirigido a personal
especializado que conozca los criterios de construcción y de los dispositivos
de protección contra accidentes con cancelas, puertas y portales motorizados
(atenerse a las normas y a las leyes vigentes).
2° -El instalador tendrá que dar al utilizador final un manual de instrucciones de
acuerdo con la 12635.
3° -El instalador antes de proceder con la instalación tiene que hacer un analisis de
los riesgos del cierre automatizado final y la puesta en seguridad de los puntos
identificados como peligrosos (siguiendo las normas EN 12453 / EN 12445).
4° -El instalador antes de instalar el motor de desplazamiento tiene que controlar que
la cancela esté en buenas condiciones mecánicas y que se abra y se cierre en
forma adecuada.
5° -El instalador tendrá que instalar el órgano para el desenganche manual a una
altura inferior a 1,8 m.
6° -El instalador tendrá que quitar eventuales impedimentos para el movimiento
motorizado de la cancela (ej. pistillos, cerraduras, cerrojos, etc.).
7° - El instalador tendrá que colocar de modo permanente rótulos que adviertan de la
posibildad de aplastamiento, en un punto bastante visible o en las cercanías de
eventuales mandos fijos.
8° - El cablaje de los varios componentes eléctricos externos al operador (por ejemplo
fotocélulas, los intermitentes, etc) tiene que ser efectuado según la EN 60204-1 y
a las modificas sucesivas aportadas por el punto 5.2.2 della EN 12453.
9° - El eventual montaje de un panel de mandos para la gestión del movimiento manual
tiene que ser efectuado posicionando el panel en modo de que quien lo accione
no se encuentre en una posición peligrosa; además se tiene que hacer en modo
que sea mínimo el riesgo de accionamiento accidental de los pulsadores.
10° - Tener los mandos del automatismo (panel de mandos, mando a distancia, etc.)
lejos del alcance de los niños. El òrgano de maniobra (un interruptor cerrado
manualmente) tiene que estar en una posiciòn visible desde la parte de maniobra,
pero lejana de las piezas en movimiento. Tiene que ser instalado en una altura
mìn. de 1,5 metros.
11° - Esta unidad puede ser utilizado por niños de 8 años o más y las personas con
capacidades físicas, sensoriales o mentales reducidas, o falta de experiencia y
conocimientos que hayan recibido supervisión o instrucciones relativas al uso de
‘equipo de manera segura y comprender los riesgos que implica.
12° - Los niños no deben jugar con el aparato.
13° - Limpieza y mantenimiento de usuarios no tiene que ser hecho por los niños sin
supervisión.
14° - No permita que los niños jueguen con los controles fijos. Mantenga los controles
remotos alejados de los niños.
15° - Los mecanismos de mando fijos tienen que ser instalados de manera visible.
16° - Antes de ejecutar cualquier operación de instalación, ajuste o mantenimiento del
sistema, quitar la corriente accionando el respectivo interruptor magnetotérmico
conectado antes del mismo.
17° - Al final de la instalación, el instalador tendrá que asegurarse de que las partes de
la puerta no estorben calles o aceras públicas.
LA EMPRESA RIB NO SE RESPONSABILIZA por eventuales daños provocados
por la falta de respeto de las normas de seguridad, durante la instalación y de
las leyes actualmente vigentes.
4
I
LAYOUT IMPIANTO
❸
❷
CARATTERISTICHE TECNICHE
KING 24V è un operatore irreversibile utilizzato per movimentare cancelli a
battente con ante lunghe fino a 4 m (Fig. 1).
KING 24V è stato concepito per funzionare senza finecorsa elettrici, ma solo
meccanici.
❹
CARATTERISTICHE
TECNICHE
❶
❺
❶
❺ ❹
KING 24V
Lunghezza max anta
m
4
Peso max anta
kg
400
Corsa max di traino
mm
Tempo medio di apertura
s.
14÷27
Velocità di traino
m/s.
0,0125
Forza max di spinta
N
1800
Alimentazione e frequenza
24V
24V
Potenza motore
W
118
Assorbimento
A
5,4
Cicli consigliati al giorno
n°
Servizio
1 - Operatore KING 24V
2 - Antenna radio
3 - Lampeggiatore
4 - Selettore a chiave
5 - Fotocellule esterne
150
90%
Cicli consecutivi garantiti
1
345*
n°
Lubrificazione a grasso
200/14s
Bechem - RHUS 550
Peso motore
kg
10
Rumorosità
db
<70
Volume
m3
0,0184
Temperatura di lavoro
°C
-10 ÷ +55°C
Grado di protezione
IP
44
* Con fermo meccanico incorporato che interviene durante l’apertura. Se si utilizza anche
il fermo meccanico che interviene durante la chiusura, opzionale, la corsa massima di
traino si riduce di 50 mm.
NERO 1
Collegare a J5 o J6 morsetto +
NERO 2
Collegare a J5 o J6 morsetto Misure in mm
2
5
I
INSTALLAZIONE KING 24V
CONTROLLO PRE-INSTALLAZIONE
Le ante devono essere solidamente fissate ai cardini delle colonne, non devono flettere
durante il movimento e devono muoversi senza attriti.
Prima d’installare KING 24V è meglio verificare tutti gli ingombri necessari per poterlo
installare.
Se il cancello si presenta come da Fig. 1 non occorrono modifiche.
È obbligatorio uniformare le caratteristiche del cancello alle norme e leggi
vigenti. Il cancello può essere automatizzato solo se in buono stato e se rispondente
alla norma EN 12604.
- L’anta non deve presentare porte pedonali. In caso contrario occorrerà prendere
opportune precauzioni in accordo al punto 5.4.1 della EN12453 (ad esempio impedire
il movimento del motore quando il portoncino è aperto, grazie ad un microinterruttore
opportunamente collegato al quadro elettronico).
- Non bisogna generare punti di intrappolamento (ad esempio tra anta aperta del cancello
e cancellata).
- Non devono essere presenti fermi meccanici al di sopra del cancello perché non sono
sufficientemente sicuri.
3
Componenti da installare secondo la norma EN12453
USO DELLA CHIUSURA
TIPO DI COMANDO
Persone esperte
(fuori da area pubblica*)
Persone esperte
(area pubblica)
Uso illimitato
a uomo presente
A
B
non possibile
a impulsi in vista
(es. sensore)
CoE
CoE
C e D, o E
a impulsi non in vista
(es. telecomando)
CoE
C e D, o E
C e D, o E
C e D, o E
C e D, o E
C e D, o E
automatico
4
* esempio tipico sono le chiusure che non accedono a pubblica via
A: Pulsante di comando a uomo presente (cioè ad azione mantenuta), come cod.
ACG2013
B: Selettore a chiave a uomo presente, come cod. ACG1010
C: Regolazione della forza del motore
D: Coste e/o altri dispositivi di limitazione delle forze entro i limiti della norma EN12453
- Appendice A.
E: Fotocellule, es. cod. ACG8026 (Da applicare ogni 60÷70cm per tutta l’altezza della
colonna del cancello fino ad un massimo di 2,5m - EN 12445 punto 7.3.2.1)
5
Ingrassare
accuratamente
6
SBLOCCO DI EMERGENZA
In caso di mancanza di corrente, per poter agire manualmente sul cancello è sufficiente
inserire l’apposita chiave e ruotarla 2 volte in senso antiorario (Fig. 3).
Per poter eseguire in modo sicuro la movimentazione manuale dell’anta occorre verificare
che:
- sull’anta siano presenti maniglie idonee;
- tali maniglie siano posizionate in modo da non creare punti di pericolo durante il loro
utilizzo;
- lo sforzo manuale per muovere l’anta non superi i 225N per i cancelli posti su siti privati
ed i 390N per i cancelli posti su siti commerciali ed industriali (valori indicati nel punto
5.3.5 della norma EN 12453).
SI !
Assicurarsi di stringere
il bullone che fissa
l’operatore alla staffa
permettendo che la stessa
possa ruotare liberamente.
FISSAGGIO ATTACCO MOTORE A COLONNA
Installando il KING 24V è necessario rispettare alcune misure per avere un corretto
movimento dell’anta.
Se la colonna è in ferro le si può avvitare direttamente l’attacco utilizzando quattro viti
filettate M8.
Se la colonna è in cemento fissare l’attacco con quattro viti ad espansione di Ø 8 mm.
In caso si abbia il muro parallelo al cancello quando questo è aperto, può essere
necessario praticare una nicchia per dare una sede all’operatore.
NO !
L’operatore non deve
variare la sua altezza
nelle varie fasi della
movimentazione.
FISSAGGIO ATTACCO MOTORE A CANCELLO
Prima di inserire il perno nell’attacco cancello, ingrassare accuratamente.
Saldare l’attacco a cancello alla giusta altezza (Fig. 6, 7).
Durante l’installazione aprire e chiudere più volte il cancello controllando che l’operatore
non sfreghi contro l’anta in movimento.
6
I
COL
Attacco colonna
Z
Y
X
S1
Rispettare la misura
e assicurarsi che
l’operatore sia orizzontale
45
Z
Y
ANT
X
S2
Attacco anta
Z
A
Y
B
X
S3
7
MISURE DA RISPETTARE PER UNA CORRETTA INSTALLAZIONE
L
Min.÷Max
a
A
max
B
C
D
E
T
sec
ANT
ANT
COL
1÷1,80
45
100
100
815
90
14
A
S3-Y
1,81÷2,20
45
110
110
815
90
18
A
S3-X
2,21÷2,50
90°
70
140
110
815
90
20
A
S1-Z
2,51*÷3,00*
90
170
140
815
115
25
B
S2-Y
3,01*÷3,50*
115
200
140
815
115
27
B
S2-Y
B
C
D
E
ANT
COL
90
140
815
90
20
A
S1-Z
100
130
815
90
21
A
S2-Y
110
140
815
115
24
B
S1-Y
L
Min.÷Max
a
A
max
1÷1,80
1,81÷2,20
2,21÷2,50*
110°
20
T
sec
Attacco anta
A
B
COL
Attacco colonna
Z
Y
X
S1
MISURE DA RISPETTARE CON 2 FERMI MECCANICI
*
Oltre i 2,5 metri di lunghezza d’anta deve essere
applicata una elettroserratura per assicurare
un’efficace chiusura.
Qualora il pilastro fosse molto largo e non fosse possibile
installare l’operatore rispettando la misura (B), è indispensabile
creare una nicchia nel pilastro o spostare il cancello sullo
spigolo.
L
Min.÷Max
a
1÷1,80
1,81÷2,20
2,21÷2,50
90°
2,51*÷3,00*
L
Min.÷Max
a
A
C
D
E
45
100
100
775
90
14
45
110
110
775
90
70
140
110
775
115
70
160
140
775
115
B
C
D
E
A
max
1÷1,80
1,81÷2,20
2,21÷2,50*
7
110°
T
B
max
20
ANT
COL
A
S3-Y
18
A
S3-X
20
B
S1-Z
25
B
S1-Y
ANT
COL
sec
T
sec
90
140
775
90
20
A
S1-Z
100
130
775
90
21
A
S2-Y
110
140
775
115
24
B
S1-Y
I
FERMO MECCANICO - OPTIONAL
Cod. ACG8089
Fermo meccanico, optional, per fermare la chiusura in caso il cancello sia privo di un
fermo a terra (Fig. 8).
8
REGOLAZIONE FINECORSA MECCANICI
Per posizionare i fermi agire come da schema (Fig. 9).
Per ottenere l’apertura desiderata è sufficiente spostare il fermo (A) e bloccarlo serrando
la vite da 8mA con una chiave fissa n° 13.
Per ottenere la chiusura desiderata si dovrà spostare il fermo (B) (OPZIONALE)
bloccandolo come descritto per il fermo (A).
9
MANUTENZIONE
Da effettuare solamente da parte di personale specializzato dopo aver tolto l’alimentazione
elettrica.
Ogni anno ingrassare i cardini e controllare la forza di spinta esercitata dall’operatore
sull’anta.
Ogni due anni è consigliabile lubrificare la madrevite con del grasso siliconico.
10
8
T2 24V
T2 24V CRX
COLLEGAMENTI ELETTRICI
cod. AC07088
cod. AC07089
24Vdc 0,8A ± 15% per ACCESSORI
24Vdc 0,8A ± 15% per AUTOTEST COSTE
PEDONALE
PASSO PASSO
SERRATURA
ELETTRICA
FOTOCELLULE
COMUNE
COSTE
LED
LAMPEGGIATORE
24Vdc 20W
R=2,2K 1/4W
ALIMENTAZIONE
230Vac 50Hz
FUSE
T2A
TRASFORMATORE
COMUNE
CHIUDE
APRE
STOP
ANTENNA
CALZA
ANTENNA
M1
M2
9
I
I
A - CONNESSIONI
J1
NF
Alimentazione 230 Vac 50/60 Hz - esterna alla scheda (120V/60Hz a richiesta)
J2
COM.
Comune dei contatti
CLOSE
Contatto impulso di chiusura (NA)
OPEN
Contatto impulso di apertura (NA)
STOP
Contatto impulso di stop (NC)
AERIAL
Antenna radio
SIGNAL
Spia cancello aperto e segnalazione stato di funzionamento
con batteria e batteria scarica (24Vdc 3W max)
A+TEST
Positivo per alimentazione autotest costa
EDGE N.C.
Contatto costa (NC)
COM.
Comune dei contatti
PHOTO N.C.
Contatto fotocellule (NC)
K BUTT.
Contatto impulso singolo (NA)
PED. BUTT.
Contatto comando apertura pedonale (NA)
A+
Positivo per alimentazione accessori a 24Vdc
A-
Negativo per alimentazione accessori a 24Vdc
LOCK
Collegamento elettroserratura (MAX 15W 12V)
J3
J1
J2
J9
J10
J5
J6
J8
SECONDARY
TRANSFORMER
Connettore per secondario trasformatore 18 Vac
J5
MOTOR 1
Collegamento MOTORE 1 (senza polarità)
J6
MOTOR 2
Collegamento MOTORE 2 (senza polarità)
SW T2 24V
Connettore dedicato alla programmazione in fabbrica. NON
TOCCARE IL PONTICELLO! SE VIENE RIMOSSO L’OPERATORE
NON FUNZIONA!
J7
SW RADIO
Connettore dedicato alla programmazione in fabbrica (solo
per modelli CRX). NON TOCCARE IL PONTICELLO! SE VIENE
RIMOSSO L’OPERATORE NON FUNZIONA!
S3
J9
RADIO
Modulo radio incorporato (modello CRX), o connettore per
radio ricevitore RIB ad innesto con alimentazione a 24Vdc
J10
BATTERY
CHARGER
Connettore per scheda di ricarica batteria a 24Vdc (cod.
ACG4648)
TR1
TRIMMER RUN
Trimmer di regolazione dell’alta velocità
TR2
TRIMMER LOW
SPEED
Trimmer di regolazione della bassa velocità
TR3
TRIMMER TCA
Trimmer di regolazione del tempo di attesa prima di avere la
chiusura automatica (DI DEFAULT NON ABILITATO E LED DL6
SPENTO)
B - SETTAGGI
TRANSFORMER
FUSE 1
J4
J8
J3
J4
Collegamento fase negativa lampeggiatore a 24Vdc (cod.
ACG7061) Attenzione alle polarità.
J7
F1
TR3
TR1
DIP 1(ON) - CONTROLLO SENSO DI ROTAZIONE DEL MOTORE (PUNTO C)
DIP 2(ON) - PROGRAMMAZIONE TEMPI (PUNTO D)
DIP 3(ON) - ABILITAZIONE RILASCIO ANTE DURANTE LE FASI DI RALLENTAMENTO,
E IN APERTURA E CHIUSURA TOTALE (PER RISPETTO DELLE PROVE DI
IMPATTO SECONDO EN12453)
DIP 1-2­
MEMORIZZAZIONE/CANCELLAZIONE CODICI RADIO PER COMANDO
APERTURA TOTALE (SOLO MODELLO CRX) (PUNTO E)
DIP 1-3
MEMORIZZAZIONE/CANCELLAZIONE CODICI RADIO PER COMANDO
APERTURA PEDONALE (SOLO MODELLO CRX) (PUNTO F)
DIP 2-1PROGRAMMAZIONE TEMPI APERTURA PEDONALE MICROINTERRUTTORI DI
GESTIONE
DIP 4 Fotocellule sempre attive (OFF) - Fotocellule attive solo in chiusura (ON)
DIP 5 Prelampeggio (ON) - Lampeggio normale (OFF)
DIP 6
Comando impulso singolo (K BUTT) e Ricevitore radio passo passo (OFF) automatico (ON)
DIP 7Funzionamento con sensore di corrente (ON-attivato) Funzionamento a tempo
(OFF-attivato).
DIP 8Abilitazione serratura elettrica (ON-attivato)
DIP 9Abilitazione colpo di sgancio serratura elettrica (ON-attivata)
DIP 10 Abilitazione colpo di aggancio serratura elettrica (ON- attivato)
DIP 11 Abilitazione facilitazione sblocco (ON-attivata)
S3
PROG
Pulsante per la programmazione
FUSE 1 T 8 A
Fusibile di protezione motori
F1
Fusibile di protezione trasformatore
T2A
TR2
DIP 12 Abilitazione TEST monitoraggio costa (ON- attivato ).
DIP 13Selezione funzionamento con 1 o 2 motori (di default OFF 2 motori)
DIP 14ON - KING 24V
DIP 15OFF - KING 24V
DIP 16CHIUSURA IMMEDIATA DOPO AVER TRANSITATO DAVANTI ALLE
FOTOCELLULE
ONABILITATA
OFFDISABILITATA
JP1 => Verificare che il ponticello sia inserito!
JP2 => Verificare che il ponticello sia inserito!
JP3 => Verificare che il ponticello sia inserito!
PROG => S3 Pulsante per la programmazione
REGOLAZIONI
ATTENZIONE: ABILITARE IL DIP 3 SOLO DOPO AVER ESEGUITO TUTTE LE
PROGRAMMAZIONI.
NOTA: CON DIP 3 (ON) SI ABILITA LA FUNZIONE DI INVERSIONE BREVE DELLE ANTE
DOPO IMPATTO.
QUESTA INVERSIONE BREVE DELLE ANTE PERMETTE DI RIDURRE A ZERO LA FORZA
STATICA ENTRO I 5 SECONDI INDICATI DALLA NORMA EN12453 AL PUNTO A.2.2
(FORZE STATICHE AMMISSIBILI) CONSENTENDO QUINDI IL RISPETTO DELLE PROVE
DI IMPATTO INDICATE SEMPRE DALLA EN12453).
10
I
IN CASO NON SUSSISTA LA NECESSITA’ DI OTTEMPERARE ALLA NORMA SOPRA
DESCRITTA, E’ SUFFICIENTE POSIZIONARE IL DIP 3 IN OFF. IN QUESTO CASO LE
ANTE SI FERMERANNO SENZA INVERTIRE IL MOVIMENTO.
TRIMMER RUN (TR1) Regolatore elettronico dell’alta velocità
Con questo trimmer è possibile regolare la velocità del motore (di default viene settato al
massimo della velocità). La regolazione ha grande utilità per rendere l’automazione conforme
alle norme europee in materia di impatti.
TRIMMER LOW SPEED (TR2) Regolatore elettronico della velocità lenta in
accostamento
La regolazione della velocità lenta viene eseguita agendo sul Trimmer LOW SPEED tramite
il quale si varia la tensione di uscita ai capi del/dei motore/i (ruotandolo in senso orario si
aumenta la velocità). La regolazione viene eseguita per determinare la corretta velocità di
fine apertura e fine chiusura in base alla struttura del cancello o in presenza di leggeri attriti
che potrebbero compromettere il corretto funzionamento del sistema.
TRIMMER DI CHIUSURA AUTOMATICA TCA (TR3) TOTALE O PEDONALE di default
NON ABILITATO e LED DL6 SPENTO (TRIMMER RUOTATO COMPLETAMENTE IN
SENSO ANTIORARIO)
Con questo trimmer è possibile eseguire la regolazione del tempo prima di avere la chiusura
automatica totale o pedonale. Si ottiene solo con porta completamente (totale) o parzialmente
(pedonale) aperta e led DL6 acceso (con trimmer ruotato in senso orario). Il tempo di pausa
può essere regolato da un minimo di 2 secondi ad un massimo di 2 minuti.
SEGNALAZIONI LED
DL1 programmazione attivata (rosso)
DL2 cancello in apertura M2 (verde)
DL3 cancello in chiusura M2 (rosso)
DL4 cancello in apertura M1 (verde)
DL5 cancello in chiusura M1 (rosso)
DL6 segnalazione tempo chiusura automatica (rosso)
DL7 contatto fotocellule (NC) (rosso)
DL8 contatto costa (NC) (rosso)
DL9 comando pulsante STOP (NC) (rosso)
DL10 programmazione codici radio (verde)
(inversioni, stop, allarmi, ecc....).
8 - La chiusura delle ante verrà eseguita in modalità veloce (in base a quanto da voi settato
sul trimmer RUN) e in prossimità della totale chiusura in modalità rallentata (in base a
quanto da voi settato sul trimmer LOW SPEED).
9 - Al raggiungimento della chiusura i sensori di corrente fermano il cancello.
10 - A FINE PROGRAMMAZIONE RIMETTERE IL DIP 2 SU OFF.
D-
PROGRAMMAZIONE TEMPI PER 1 MOTORE (M1) (#) CON
SENSORE DI CORRENTE ABILITATO (DIP 7 ON)
ATTENZIONE: PER GESTIRE UN SOLO MOTORE IL DIP 13 DEVE ESSERE POSIZIONATO
IN ON DURANTE LA PROGRAMMAZIONE IL SENSORE DI CORRENTE È SEMPRE
ATTIVO.
Il cancello deve essere completamente chiuso.
1 - Mettete DIP 2 su ON => Il led DL1 emetterà dei lampeggi brevi.
2 - Premete il pulsante PROG. => M1 apre.
Raggiunto il fermo meccanico di apertura, il SENSORE DI CORRENTE ferma M1 (con
memorizzazione del tempo e della corrente).
3 - Premete il pulsante PROG. => M1 chiude.
Nello stesso istante il led DL1 smetterà di lampeggiare segnalando l’uscita dalla
procedura di apprendimento. Da questo momento le sicurezze o altri comandi del
cancello funzioneranno normalmente (inversioni, stop, allarmi, ecc....).
Al raggiungimento della chiusura tramite il sensore di corrente il cancello si ferma.
4 - A FINE PROGRAMMAZIONE RIMETTERE IL DIP 2 SU OFF.
(#) DURANTE LA PROGRAMMAZIONE LE SICUREZZE SONO ATTIVE ED IL LORO
INTERVENTO FERMA LA PROGRAMMAZIONE (IL LED DL1 DA LAMPEGGIANTE
RIMANE ACCESO FISSO). PER RIPETERE LA PROGRAMMAZIONE POSIZIONARE IL DIP
2 SU OFF, CHIUDERE IL CANCELLO TRAMITE PROCEDURA “CONTROLLO SENSO DI
ROTAZIONE DEI MOTORI” E RIPETERE LA PROGRAMMAZIONE SCELTA.
D-
PROGRAMMAZIONE TEMPI PER 2 MOTORI (#) CON
FUNZIONAMENTO A TEMPO (DIP 7 OFF)
FUSIBILI
Fuse 1 T 8A FUSIBILE DI PROTEZIONE MOTORI
F1 T 2AFUSIBILE DI PROTEZIONE TRASFORMATORE (esterno alla scheda T2 24V)
C-C
ONTROLLO SENSO DI ROTAZIONE DEL/DEI MOTORE/I
1 - Mettere DIP 1 su ON => Il led DL1 inizia a lampeggiare.
2 - Premere e mantenere premuto il pulsante PROG. (ora il movimento é eseguito ad uomo
presente, apre-stop-chiude-stop-apre-ecc.) => I LED VERDI DL2 e DL4 si accendono
e le ante del cancello si aprono con sfasamento fisso di 2 sec. Se chiudono invece di
aprire, rilasciare il pulsante ed invertire i due fili del motore interessato.
3 - A fine apertura rilasciare il pulsante PROG. ed eseguire la taratura dei fermi meccanici
d’apertura (presenti sull’operatore).
4 - Premere e mantenere premuto il pulsante PROG => I LED ROSSI DL3 e DL5 si
accendono e le ante del cancello si chiudono con sfasamento di 2 sec.
5 - Mantenere premuto il pulsante PROG fino a che il cancello non sia completamente
chiuso.
6 - L asciare le 2 ante completamente chiuse per fare la programmazione tempi.
7 - R imettere DIP1 su OFF => Il led DL1 si spegne segnalando l’uscita dal controllo.
N.B.: Durante
­
questo controllo lo stop, le fotocellule e le coste non sono attive.
D - PROGRAMMAZIONE TEMPI PER 2 MOTORI (#) CON SENSORE DI
CORRENTE ABILITATO (DIP 7 ON)
DURANTE LA PROGRAMMAZIONE IL SENSORE DI CORRENTE È SEMPRE ATTIVO.
1 - Il cancello deve essere completamente chiuso.
2 - Mettete il DIP 2 su ON => Il led DL1 emetterà dei lampeggi brevi.
3 - Premete il pulsante PROG. => M1 apre.
4 - Raggiunto il fermo meccanico di apertura, il SENSORE DI CORRENTE AUTOMATICO
ferma M1 (con memorizzazione del tempo e della corrente)=> Nello stesso momento
si attiva M2 che apre.
5 - Raggiunto il fermo meccanico di apertura, il SENSORE DI CORRENTE AUTOMATICO ferma
M2 (con memorizzazione del tempo e della corrente).
6 - Premete il pulsante PROG. => M2 chiude.
7 - Premete il pulsante PROG. => M1 chiude determinando lo spazio di sfasamento fra M2
e M1. Nello stesso istante il led DL1 smetterà di lampeggiare segnalando l’uscita dalla
procedura di apprendimento.
Da questo momento le sicurezze o altri comandi del cancello funzioneranno normalmente
1 - Il cancello deve essere completamente chiuso.
2 - Mettete il microinterruttore DIP 2 su ON => Il led DL1 emetterà dei lampeggi brevi.
3 - Premete il pulsante PROG. => M1 apre.
4 - Raggiunto il fermo meccanico di apertura, dopo un secondo premete il pulsante PROG.
=> M1 si ferma e M2 apre.
5 - Raggiunto il fermo meccanico di apertura => dopo 1 secondo premete il pulsante PROG.
=> M2 si ferma.
6 - Premete il pulsante PROG. => M2 chiude.
7 - Premete il pulsante PROG. => M1 chiude determinando la sfasamento fra M2 e M1.
Nello stesso istante il led DL1 smetterà di lampeggiare segnalando l’uscita dalla
procedura di apprendimento.
Da questo momento le sicurezze o altri comandi del cancello funzioneranno normalmente
(inversioni, stop, allarmi, ecc....).
8 - Finito il conteggio del tempo il cancello si ferma.
9 - A FINE PROGRAMMAZIONE RIMETTERE IL DIP 2 SU OFF.
NOTA: Il rallentamento viene determinato automaticamente dal quadro elettronico in fase di
programmazione tempi, e viene attivato a circa 50÷60 cm prima del raggiungimento
dei finecorsa meccanici di apertura o chiusura.
D-
PROGRAMMAZIONE TEMPI PER 1 MOTORE (#) CON
FUNZIONAMENTO A TEMPO (DIP 7 OFF)
ATTENZIONE: PER GESTIRE UN SOLO MOTORE IL DIP 13 DEVE ESSERE POSIZIONATO
IN ON
1 - Il cancello deve essere completamente chiuso.
2 - Mettete il microinterruttore DIP 2 su ON => Il led DL1 emetterà dei lampeggi brevi.
3 - Premete il pulsante PROG. => M1 apre.
4 - Raggiunto il fermo meccanico di apertura, dopo un secondo premete il pulsante PROG.
=> M1 si ferma.
5 - Premete il pulsante PROG. => M1 chiude.
Nello stesso istante il led DL1 smetterà di lampeggiare segnalando l’uscita dalla
procedura di apprendimento.
Da questo momento le sicurezze o altri comandi del cancello funzioneranno normalmente
(inversioni, stop, allarmi, ecc....).
6 - Finito il conteggio del tempo il cancello si ferma.
7 - A FINE PROGRAMMAZIONE RIMETTERE IL DIP 2 SU OFF.
D - PROGRAMMAZIONE TEMPI APERTURA PEDONALE (#) SIA PER
FUNZIONAMENTO A TEMPO CHE CON SENSORE DI CORRENTE
A cancello chiuso:
1 - Mettere prima il DIP2 su ON (il led DL1 lampeggia velocemente) e dopo il DIP1 su ON (il
led DL1 lampeggia lentamente).
2 - Premere il pulsante pedonale (COM-PED.BUTT) => M1 apre.
11
I
3 - Premere il pulsante pedonale per arrestare la corsa (definendo così l’apertura di M1).
4 - Premere il pulsante pedonale per avviare la chiusura.
5 - Al raggiungimento della chiusura rimettere i DIP1 e 2 su OFF.
(#) DURANTE LA PROGRAMMAZIONE LE SICUREZZE SONO ATTIVE ED IL LORO
INTERVENTO FERMA LA PROGRAMMAZIONE (IL LED DL1 DA LAMPEGGIANTE
RIMANE ACCESO FISSO).
PER RIPETERE LA PROGRAMMAZIONE POSIZIONARE I DIP 1 E 2 SU OFF, CHIUDERE IL
CANCELLO TRAMITE PROCEDURA “CONTROLLO SENSO DI ROTAZIONE DEI MOTORI”
E RIPETERE LA PROGRAMMAZIONE SCELTA.
E-P
ROGRAMMAZIONE CODICI RADIO APERTURA TOTALE
(62 CODICI MAX - SOLO MODELLI CRX)
La programmazione può essere eseguita solo a cancello fermo.
1 - Posizionare DIP 1 su ON e successivamente il DIP 2 su ON.
2 - Il led rosso DL1 di programmazione lampeggia con frequenza di 1 sec. ON e 1 sec. OFF
per 10 secondi.
3 - Premere il tasto del telecomando (normalmente il canale A) entro i 10 secondi impostati.
Se il telecomando viene correttamente memorizzato il led DL10 (verde) emette un
lampeggio.
4 - Il tempo di programmazione dei codici si rinnova automaticamente per poter memorizzare
il telecomando successivo.
5 - Per terminare la programmazione lasciare trascorrere 10 sec., oppure premere per un
attimo il pulsante PROG. Il led rosso DL1 di programmazione smette di lampeggiare.
6 - Riposizionare DIP 1 su OFF e DIP 2 su OFF.
7 - Fine procedura.
PROCEDURA CANCELLAZIONE DI TUTTI I CODICI RADIO DEDICATI ALL’APERTURA
TOTALE
La cancellazione può essere eseguita solo a cancello fermo.
1 - Posizionare il DIP 1 su ON e successivamente il DIP 2 su ON.
2 - Il led rosso DL1 di programmazione lampeggia con frequenza di 1 sec. ON e 1 sec. OFF
per 10 secondi.
3 - Premere e mantenere premuto il pulsante PROG per 5 secondi. La cancellazione della
memoria viene segnalata da due lampeggi del led verde DL10.
4 - Il led rosso DL1 di programmazione rimane attivo ed è possibile inserire nuovi codici come
da procedure sopra descritte.
5 - Riposizionare DIP 1 su OFF e DIP 2 su OFF.
6 - Fine procedura.
SEGNALAZIONE MEMORIA SATURA CODICI RADIO DEDICATI ALL’APERTURA TOTALE
La segnalazione si può ottenere solo a cancello fermo.
1 - Posizionare il DIP 1 su ON e successivamente il DIP 2 su ON.
2 - Il led verde DL10 lampeggia per 6 volte segnalando memoria satura (62 codici presenti).
3-
Successivamente il led DL1 di programmazione rimane attivo per 10 secondi,
consentendo un eventuale cancellazione totale dei codici.
4 - Riposizionare DIP 1 su OFF e DIP 2 su OFF.
5 - Fine procedura.
F - PROGRAMMAZIONE CODICI RADIO APERTURA PEDONALE (62
CODICI MAX - SOLO MODELLI CRX)
La programmazione può essere eseguita solo a cancello fermo.
1 - Posizionare DIP 1 su ON e successivamente il DIP 3 su ON.
2 - Il led rosso DL1 di programmazione lampeggia con frequenza di 1 sec. ON e 1 sec. OFF
per 10 secondi.
3 - Premere il tasto del telecomando (normalmente il canale B) entro i 10 secondi impostati.
Se il telecomando viene correttamente memorizzato il led DL10 (verde) emette un
lampeggio.
4 - Il tempo di programmazione dei codici si rinnova automaticamente per poter memorizzare
il telecomando successivo.
5 - Per terminare la programmazione lasciare trascorrere 10 sec., oppure premere per un
attimo il pulsante PROG. Il led rosso DL1 di programmazione smette di lampeggiare.
6 - Riposizionare DIP 1 su OFF e DIP 3 su OFF.
NOTA: SE IL LED DL1 CONTINUA A LAMPEGGIARE VELOCEMENTE, SIGNIFICA
CHE IL DIP 1 RISULTA ANCORA POSIZIONATO IN ON E QUALSIASI MANOVRA
VIENE NEGATA.
7 - Fine procedura.
PROCEDURA CANCELLAZIONE DI TUTTI I CODICI RADIO DEDICATI ALL’APERTURA
PEDONALE
La cancellazione può essere eseguita solo a cancello fermo.
1 - Posizionare il DIP 1 su ON e successivamente il DIP 3 su ON.
2 - Il led rosso DL1 di programmazione lampeggia con frequenza di 1 sec. ON e 1 sec. OFF
per 10 secondi.
3 - Premere e mantenere premuto il pulsante PROG per 5 secondi. La cancellazione della
memoria viene segnalata da due lampeggi del led verde DL10.
4 - Il led rosso DL1 di programmazione rimane attivo ed è possibile inserire nuovi codici come
da procedure sopra descritte.
5 - Riposizionare DIP 1 su OFF e DIP 3 su OFF.
6 - Fine procedura.
SEGNALAZIONE MEMORIA SATURA CODICI RADIO DEDICATI ALL’APERTURA
PEDONALE
La segnalazione si può ottenere solo a cancello fermo.
1 - Posizionare il DIP 1 su ON e successivamente il DIP 3 su ON.
2 - Il led verde DL10 lampeggia per 6 volte segnalando memoria satura (62 codici presenti).
3-
Successivamente il led DL1 di programmazione rimane attivo per 10 secondi,
consentendo un eventuale cancellazione totale dei codici.
4 - Riposizionare DIP 1 su OFF e DIP 3 su OFF.
5 - Fine procedura.
FUNZIONAMENTO ACCESSORI DI COMANDO
ATTENZIONE: COLLEGARE ACCESSORI DI COMANDO SOLO SE IMPULSIVI.
Assicurarsi che eventuali altri tipi di accessori di comando (per esempio
sensori magnetici) siano programmati nella modalità IMPULSIVA, altrimenti
attiverebbero la movimentazione del cancello senza sicurezze attive.
PULSANTE DI COMANDO PASSO-PASSO (COM-K BUTTON)
Se DIP 6 su OFF =>Esegue un comando ciclico dei comandi apre-stop-chiude-stopapre ecc.
Se DIP 6 su ON =>
Esegue l’apertura a cancello chiuso. Se azionato durante il
movimento di apertura non ha effetto. Se azionato a cancello aperto
lo chiude e durante la chiusura se azionato lo fa riaprire.
PULSANTE DI APERTURA (COM-OPEN)
A cancello fermo il pulsante comanda il moto di apertura. Se viene azionato durante la
chiusura fa riaprire il cancello.
FUNZIONE OROLOGIO DEL PULSANTE DI APERTURA
Se desiderate applicare un orologio (o più semplicemente un’interruttore) per
aprire e mantenere aperto il cancello, dovete richiedere T2 24V con fw 03 NOUP.
Se fw 03 o superiore ATTENZIONE: IN CASO DI GUASTO ALLE SICUREZZE, UN
MINUTO DOPO CHE L’OROLOGIO O L’INTERRUTTORE SONO STATI ATTIVATI, IL
CANCELLO SI APRIRA’ SENZA SICUREZZE ATTIVE !
La funzione orologio è utile nelle ore di punta, quando il traffico veicolare risulta rallentato
(es. entrata/uscita operai, emergenze in zone residenziali o parcheggi e, temporaneamente,
per traslochi).
MODALITÁ DI APPLICAZIONE FUNZIONE OROLOGIO
Richiedere T2 24V con firmware 02.
Collegando un interruttore e/o un orologio di tipo giornaliero/settimanale (al posto o in
parallelo al pulsante di apertura N.O. “COM-OPEN”), è possibile aprire e mantenere aperta
l’automazione finché l’interruttore viene premuto o l’orologio rimane attivo.
Ad automazione aperta vengono inibite tutte le funzioni di comando.
Rilasciando l’interruttore, o allo scadere dell’ora impostata, si avrà la chiusura immediata
dell’automazione.
PULSANTE DI CHIUSURA (COM-CLOSE)
A cancello fermo comanda il moto di chiusura.
TELECOMANDO
Se DIP 6 su OFF =>Esegue un comando ciclico dei comandi apre-stop-chiude-stop-apreecc.
Se DIP 6 su ON =>Esegue l’apertura a cancello chiuso. Se azionato durante il movimento
di apertura non ha effetto. Se azionato con cancello aperto, lo chiude.
Se azionato durante il movimento di chiusura lo fa riaprire.
PULSANTE APERTURA PEDONALE (COM-PED.BUTT.)
Comando dedicato ad un’apertura parziale e alla sua richiusura.
Durante l’apertura, la pausa o la chiusura pedonale, è possibile comandare l’apertura da
qualsiasi comando collegato sulla scheda T2 24V.
Tramite DIP 6 è possibile scegliere la modalità di funzionamento del pulsante di comando
pedonale.
Se DIP 6 su OFF =>Esegue un comando ciclico dei comandi apre stop-chiude-stop ecc.
Se DIP 6 su ON =>Esegue l’apertura a cancello chiuso. Se azionato durante il movimento
di apertura non ha effetto. Se azionato a cancello aperto lo chiude e
durante la chiusura, se azionato, lo fa riaprire.
SERRATURA ELETTRICA (LOCK)
Mettere il DIP 8 su ON per abilitare il comando della serratura elettrica in apertura.
12
I
COLPO DI SGANCIO SERRATURA ELETTRICA IN APERTURA
Mettere il DIP 9 su ON per abilitare il colpo di sgancio della serratura elettrica in apertura (a
condizione che DIP 8 sia su ON).
A cancello chiuso, se si preme un comando di apertura, il cancello per 0,5s esegue la
manovra di chiusura e contemporaneamente viene attivata la serratura elettrica (seguita da
0,5s di pausa e quindi dall’apertura del cancello).
COLPO DI AGGANCIO SERRATURA ELETTRICA
Mettere il DIP 10 su ON per abilitare il colpo di aggancio della serratura elettrica in chiusura.
A chiusura avvenuta vengono comandati per 0,5s i motori a piena tensione per garantire
l’aggancio della serratura.
FACILITAZIONE SBLOCCO MOTORI
Mettere il DIP 11 su ON per abilitare la facilitazione sblocco manuale (a condizione che il DIP
10 sia su ON), a chiusura avvenuta verrà eseguita una manovra di inversione con un tempo
fisso di 0,2s per facilitare lo sblocco manuale.
FUNZIONAMENTO ACCESSORI DI SICUREZZA
FOTOCELLULA (COM-PHOT)
DIP 4 OFF => A cancello chiuso se un ostacolo è davanti al raggio delle fotocellule, il
cancello non apre. Durante il funzionamento le fotocellule intervengono sia
in apertura (con ripristino del moto in apertura solo dopo la liberazione del
raggio delle fotocellule), che in chiusura (con ripristino del moto inverso solo
dopo la liberazione del raggio delle fotocellule).
DIP 4 ON => A cancello chiuso se un ostacolo è davanti al raggio delle fotocellule e viene
comandata l’apertura, il cancello apre (durante l’apertura le fotocellule non
interverranno). Le fotocellule interverranno solo in fase di chiusura (con
ripristino del moto inverso dopo un secondo anche se le stesse restano
impegnate).
GESTIONE CHIUSURA IMMEDIATA DOPO IL TRANSITO DA FOTOCELLULE
DIP 16 ON e DIP 4 OFF =>Mentre il cancello apre, transitando davanti alle fotocellule il
cancello si ferma. Completato il transito, dopo 1 secondo il
cancello chiude.
DIP 16 ON e DIP 4 ON =>Mentre il cancello apre, transitando davanti alle fotocellule il
cancello continua ad aprire. Completato il transito, il cancello
si ferma e dopo 1 secondo di pausa inverte il moto in
chiusura.
Se si raggiunge la completa apertura (fine tempo di
apertura), la chiusura immediata viene esclusa e viene
attivato il tempo di chiusura automatica (se trimmer
TCA abilitato e led DL6 acceso).
Se durante la chiusura si ha un transito veloce (es.
pedone) il cancello riaprirà per due secondi per poi
richiudere nuovamente.
DIP 12 OFF =>
chiusura immediata dopo il transito dalle fotocellule
disabilitata.
N.B.: S i raccomanda di verificare la funzionalità delle fotocellule almeno ogni 6 mesi.
EDGE (COSTA) (COM-EDGE)
Durante l’apertura, se impegnata, inverte il moto in chiusura.
Durante la chiusura, se impegnata, inverte il moto in apertura.
Se rimane impegnata dopo il primo impegno, esegue un’ulteriore inversione dopo 2 secondi,
per poi eseguire un’ulteriore piccola inversione e quindi segnalare l’allarme di costa guasta
o impegnata (contatto NO).
Se la costa rimane impegnata (contatto NO) nessuna movimentazione è consentita.
Se non usata, ponticellare i morsetti COM-EDGE.
MONITORAGGIO COSTE DI SICUREZZA (A+TEST A-)
Tramite l’ingresso A+TEST ed il DIP 12 ON è possibile monitorare la/le costa/e.
Il monitoraggio consiste in un Test Funzionale, della costa, eseguito al termine di ogni
completa apertura del cancello.
Dopo ogni apertura, la chiusura del cancello viene pertanto consentita solo se la/le costa/e
hanno superato il Test Funzionale.
ATTENZIONE: IL MONITORAGGIO DELL’INGRESSO COSTA PUÒ ESSERE ABILITATO CON IL
DIP 12 IN ON, OPPURE DISABILITATO CON IL DIP 12 IN OFF. INFATTI, IL TEST FUNZIONALE
DELLE COSTE E’ POSSIBILE SOLO NEL CASO SI TRATTI DI DISPOSITIVI DOTATI DI UN
PROPRIO ALIMENTATORE DI CONTROLLO.
UNA COSTA MECCANICA NON PUO’ ESSERE MONITORATA, PERTANTO IL DIP 12 DEVE
ESSERE POSIZIONATO IN OFF.
ALLARME DA AUTOTEST COSTA (DIP 12 ON)
A fine apertura se il monitoraggio della costa ha esito negativo, subentra un allarme
visualizzato dal lampeggiatore che rimane acceso, in questa condizione la chiusura del
cancello non viene consentita, solo riparando la costa e premendo uno dei comandi abilitati
e’ possibile ripristinare la normale funzionalità.
PULSANTE DI STOP (COM-STOP)
Durante qualunque operazione il pulsante di STOP esegue il fermo del cancello.
Se premuto a cancello aperto totalmente (o parzialmente utilizzando il comando pedonale) si
esclude temporaneamente la chiusura automatica (se abilitata tramite trimmer TCA e led DL6
acceso). E quindi necessario dare un nuovo comando per farlo richiudere.
Al ciclo successivo la funzione chiusura automatica viene riattivata (se abilitata tramite
trimmer TCA e led DL6 acceso).
ALLARME DA SENSORE DI CORRENTE
La centrale T2 24V è dotata di sensori automatici che fanno invertire la marcia del cancello
nel caso di impatti contro cose o persone in conformità alle norme EN vigenti (verificare
sempre con apposito strumento il rispetto dei valori imposti dalla norma), senza dover
effettuare particolari regolazioni sulla centrale, in quanto gestiti da uno speciale software
interno.
Se dopo un primo intervento del sensore di corrente in apertura o chiusura (solo ad alta
velocità) se ne ha un secondo, ovviamente nel senso contrario, il cancello si ferma e quindi
inverte per 1 secondo.
Lo stato di allarme verrà visualizzato dal lampeggiatore che rimarrà attivo per un minuto,
durante questo tempo è possibile ristabilire il funzionamento del cancello premendo un
qualsiasi pulsante di comando.
FUNZIONAMENTO AD UOMO PRESENTE IN CASO DI GUASTO DELLE SICUREZZE
Se la costa è guasta o impegnata per più di 5 secondi, o se la fotocellula è guasta o
impegnata per più di 60 secondi, i comandi APRE, CHIUDE, K BUTTON E PEDONALE
funzioneranno solo ad uomo presente.
La segnalazione dell’attivazione di questo funzionamento è data dal led di programmazione
che lampeggia.
Con questo funzionamento viene consentita l’apertura o la chiusura solo mantenendo
premuti i pulsanti di comando. Il comando radio e la chiusura automatica vengono esclusi
in quanto il loro funzionamento non è consentito dalle norme.
Al ripristino del contatto delle sicurezze, dopo 1 secondo, viene automaticamente riabilitato
il funzionamento automatico o passo passo e quindi anche il radiocomando e la chiusura
automatica riprendono a funzionare.
Nota 1: durante questo funzionamento in caso di guasto alle coste (oppure fotocellule) le
fotocellule (oppure coste) funzionano ancora interrompendo la manovra in atto.
Nota 2: il pulsante di stop non è considerato una sicurezza da bypassare in questa modalità,
pertanto se viene premuto o è rotto, non consente alcuna manovra.
La manovra a uomo presente è esclusivamente una manovra di emergenza che
deve essere effettuata per brevi periodi e con la sicurezza visiva del movimento
dell’automatismo. Appena possibile le protezioni guaste devono essere ripristinate
per un corretto funzionamento.
LAMPEGGIATORE
N.B.: Questo quadro elettronico può alimentare SOLO LAMPEGGIATORI CON CIRCUITO
LAMPEGGIANTE (ACG7061) con lampade da 24V e 20W massimo.
FUNZIONE PRE-LAMPEGGIO
DIP 5 - OFF => il motore e il lampeggiatore partono contemporaneamente.
DIP 5 - ON => il lampeggiatore parte 3 secondi prima del motore.
SPIA DI SEGNALAZIONE CANCELLO APERTO (COM-SIGNAL)
Ha il compito di segnalare gli stati di cancello aperto, parzialmente aperto o comunque non
chiuso totalmente. Solo a cancello completamente chiuso si spegne.
Durante la programmazione questa segnalazione è attiva.
N.B.: Max 3 W. Se si eccede con le pulsantiere o con le lampade, la logica del quadro
elettronico ne risulterà compromessa con possibile blocco delle operazioni.
FUNZIONAMENTO DOPO BLACK-OUT (SENZA BATTERIE)
Al ritorno della tensione di rete il led DL1 si accende e rimane acceso per tutto il tempo in cui
il cancello rimane aperto. Si spegnerà al raggiungimento della chiusura totale del cancello.
Si consiglia di far aprire completamente il cancello. Lasciate che il cancello si chiuda da solo
con la chiusura automatica o attendete che il lampeggiatore finisca di lampeggiare prima di
comandare la chiusura.
Questa operazione consentirà al cancello di riallinearsi. Infatti, se durante il black-out i motori
sono stati sbloccati e spostati dalla normale posizione di chiusura, la prima manovra al ritorno
dell’alimentazione deve essere completa.
Se il black-out avviene durante il movimento, o a cancello aperto, e il primo comando risulta
essere quello di chiusura, la chiusura avverrà con sfasamento totale delle ante pertanto
prima chiuderà M2 e allo spegnimento di M2 chiuderà M1. Questo movimento separato dei
13
I
due motori eviterà l’accavallamento delle ante.
CARATTERISTICHE TECNICHE
- Range di temperatura
0 ÷ 55°C
- Umidita
< 95% senza condensazione
- Tensione di alimentazione230V~ ±10% (120V/60Hz a richiesta)
- Frequenza
50/60 Hz
- Alimentazione batteria
20-24VDC
- Potenza Trasformatore130VA
primario 230Vac
secondario 18Vac
- Assorbimento massimo
50 mA
- Microinterruzioni di rete
100ms
- Potenza massima spia cancello aperto24Vdc 3W (equivalente a 1 lampadina
da 3W o 5 led con resistenza in serie da
2,2 k ohm)
- Carico massimo lampeggiatore
24Vdc 20W
- Corrente disponibile per fotocellule e accessori 1A ±15%
- Corrente disponibile su connettore radio
200mA
CARATTERISTICHE TECNICHE RADIO (modello T2 24V crx)
- Frequenza Ricezione
433,92MHz
- Impedenza
52 OHM
- Sensibilità
>2,24µV
- Tempo eccitazione
300ms
- Tempo diseccitazione
300ms
- Tutti gli ingressi devono essere utilizzati come contatti puliti perchè l’alimentazione è
generata internamente (tensione sicura) alla scheda ed è disposta in modo da garantire il
rispetto di isolamento doppio o rinforzato rispetto alle parti a tensione pericolosa.
- Eventuali circuiti esterni collegati alle uscite del quadro elettronico, devono essere eseguiti
per garantire l’isolamento doppio o rinforzato rispetto alle parti a tensione pericolosa.
- Tutti gli ingressi vengono gestiti da un circuito integrato programmato che esegue un
autocontrollo ad ogni avvio di marcia.
RISOLUZIONE PROBLEMI
Dopo aver effettuato tutti i collegamenti seguendo attentamente lo schema ed aver posizionato il cancello in posizione intermedia, verificare la corretta accensione dei led rossi DL7, DL8 e DL9.
In caso di mancata accensione dei led, sempre con cancello in posizione intermedia, verificare quanto segue e sostituire eventuali componenti guasti.
DL7
spento
Fotocellule guaste
DL8
spento
Costa sicurezza guasta (In caso la costa non sia collegata, eseguire il ponticello fra Com e Edge)
DL9
spento
Pulsante di Stop guasto (In caso lo Stop non sia collegato, eseguire il ponticello fra Com e Stop).
Durante il funzionamento a uomo presente, con DIP n° 1 in ON, verificare che durante l’apertura di M1 e M2 si accendano i led verdi DL2 e DL4 e che durante la chiusura di M1 e M2 si
accendano i led rossi DL3 e DL5.
In caso contrario, invertire i fili del motore interessato.
DIFETTO
SOLUZIONE
Dopo aver effettuato i vari collegamenti e aver dato tensione, tutti i led sono spenti.
Verificare l’integrità dei fusibili F1, FUSE 1.
In caso di fusibile interrotto usarne solo di valore adeguato.
F1 T 2AFUSIBILE DI PROTEZIONE TRASFORMATORE (esterno alla scheda T2 24V)
FUSE 1 8A FUSIBILE DI PROTEZIONE MOTORI
Il motore apre e chiude, ma non ha forza e si muove lentamente.
Verificare regolazione trimmer RUN e LOW-SPEED.
Il cancello esegue l’apertura, ma non chiude dopo il tempo impostato.
Accertarsi che il trimmer TCA sia abilitato con led DL6 acceso.
Pulsante OPEN sempre inserito, sostituire pulsante o switch del comando OPEN.
Autotest costa fallito, verificare i collegamenti tra quadro elettronico e alimentatore per
coste. Attenzione: se non si stà utilizzando un alimentatore per coste il dip 12 deve essere
posizionato in OFF.
Il cancello non apre e non chiude azionando i vari pulsanti K, Radio, Open e Close.
Contatto costa sicurezza guasto. Contatto fotocellule guasto con DIP 4 OFF.
Sistemare o sostituire il relativo contatto.
La serratura elettrica non funziona.
Accertarsi di avere abilitato il DIP 8 in ON.
Il led DL1 lampeggia velocemente e nessuna movimentazione è abilitata.
Posizionare i dip switch 1, 2 o 3 in posizione OFF.
14
OPTIONAL
I
Per i collegamenti ed i dati tecnici degli accessori attenersi ai relativi libretti di istruzione.
TELECOMANDO SUN
SUN 2CH
SUN CLONE 2CH
cod. ACG6052
cod. ACG6056
SUN 4CH
SUN CLONE 4CH
cod. ACG6054
cod. ACG6058
SCHEDA DI CARICA BATTERIA
BATTERIA
cod. ACG4648
Batteria 2,2Ah 12V
cod. ACG9515
DISPOSITIVI Wi-Fi
MASTER Wi-Fi
SCHEDA DI GESTIONE SISTEMA SENZA FILI
con innesto - 12÷30V ac/dc
con morsettiera - 12÷30V ac/dc
cod. ACG6094
cod. ACG6099
NOVA Wi-Fi
FOTOCELLULE SENZA FILI
COPPIA COLONNINE NOVA
VERTIGO Wi-Fi
cod. ACG8037
cod. ACG8039
FOTOCELLULE SENZA FILI SOSTITUTIVE DELLA COSTA
VERTIGO Wi-Fi 8 cod. ACG8042 - VERTIGO Wi-Fi 10 cod. ACG8043
SPARK Wi-Fi
BLOCK Wi-Fi
SELETTORE A CHIAVE SENZA FILI
cod. ACG6098
LAMPEGGIATORE SENZA FILI
SUPPORTO LATERALE
cod. ACG7064
cod. ACG7042
F
SCHÉMA DÉTAILLÉ DE L’INSTALLATION
❸
❷
CARACTERISTIQUES TECHNIQUES
KING 24V est un operateur irréversibles utilisé pour movimenter des portails à
battans jusqu’à 4 m de longeur (Fig. 1).
KING 24V a été conçu pour fonctionner sans fins de course électrique, mais
avec des butées mécaniques.
❹
CARACTERISTIQUES
TECHNIQUES
❺
❶
❶
❺ ❹
KING 24V
Longueur maxi du battant
m
4
Poids maxi du battant
kg
400
Course maxi d’entrainement
mm
Temps moyen d’ouverture
s.
14÷27
Vitesse de traction
m/s.
0,0125
Force maxi de poussée
N
1800
Alimentation et frequence
24V
24V
Puissance moteur
W
118
Absorption
A
5,4
Cycles conseillés par jour
n°
Service
1 - Operateur KING 24V
2 - Antenne radio
3 - Signal electrique
4 - Selecteur
5 - Photocellules p/protection externe
150
90%
Cycles consécutifs garantis
1
345*
n°
Graisse
200/14s
Bechem - RHUS 550
Poids du moteur
kg
10
Bruit
db
<70
Volume
m3
0,0184
Temperature de travail
°C
-10 ÷ +55°C
Indìce de protection
IP
44
* Avec une butée mécanique incorporée qui intervient pendant l’ouverture. Si l’on utilise aussi
la butée mécanique qui intervient pendant la fermeture, en option, la course maximale
d’entraînement s’écourte de 50 mm.
NOIR 1
Connecter à J5 ou J6 borne +
NOIR 2
Connecter à J5 ou J6 borne Mesures en mm
2
16
F
INSTALLATION
CONTROLE PRE-INSTALLATION
Le portail à battant doit être solidement fixé aux cardans des colonnes, ne doit pas flechir
pendant le mouvement et doit pouvoir manoeuvrer sans effort.
Avant d’installer KING 24V, il convient de verifier tous les encombrements necessaires
pour proceder à l’installation.
Si le portail se presente comme indiqué Fig. 2, aucune modification n’est necessaire.
Il est impératif d’uniformiser les caractéristiques du portail avec les normes et
les lois en vigueur. Le portail peut être automatisé seulement si il est en bon état et
qu’il est conforme à la norme EN 12604.
- Le vantail ne doit pas comporter de portillon intégré. Dans le cas contraire, il sera
opportun de prendre les précautions décrites au point 5.4.1 de la EN 12453 (interdire,
par le biais d’un contact raccordé aux bornes adaptées de la platine électronique, la
mise en marche de l’automatisme si le portillon est ouvert).
- Ne pas générer de zone d’écrasement (par exemple entre le vantail ouvert et la cloture).
- Il ne devra y avoir aucun arrêt mécanique au-dessus du portail, étant donné que les
arrêts mécaniques ne sont pas suffisamment sûrs.
3
Parties à installer conformément à la norme EN12453
USAGE DE LA FERMETURE
TYPE DE COMMANDE
Personne expertes
(au dehors d’une zone
publique*)
Personne expertes
(zone publique)
Usage illimité
homme presente
A
B
non possible
impulsion en vue
(es. capteur)
C ou E
C ou E
C et D, ou E
C ou E
C et D, ou E
C et D, ou E
C et D, ou E
C et D, ou E
C et D, ou E
impulsion hors de vue
(es. boîtier de commande)
automatique
4
* example typique: fermetures qui n’ont pas d’accès à un chemin public
A: Touche de commande à homme present (à action maintenue), code ACG2013.
B: Sélecteur à clef à homme mort, code ACG1010.
C: Réglage de la puissance du moteur.
D: Barre palpeuse et/ou autres dispositifs de limitation des forces dans les limites de
la norme EN12453- appendice A.
E: Cellules photo-électriques, code ACG8026 (Appliquer chaque 60÷70 cm pour toute
la taille de la colonne de la porte jusqu’à un maximum de 2,5 m - EN 12445 point
7.3.2.1).
5
graisser
soigneusement
MANOEUVRE DE SECOURS
6
Pour actionner le portail manuellement il est necessaire introduire la clé appropriée dans
la serrure et la tourner 2 fois dans le sense anti-horarie (Fig. 3).
Afin de pouvoir manœuvre manuellement le vantail, il est important de vérifier que:
- Il soit fourni des poignées adaptées sur le vantail
- Ces poignées doivent être positionnées de sorte à ne pas créer un danger durant leur
utilisation.
- L’effort manuel pour mettre en mouvement le vantail ne doit pas excéder 225N pour les
portes et portails en usage privé, et 390N pour les portes et portails à usage industriel et
commercial (valeurs indiquées au paragraphe 5.3.5 de la norme EN 12453)
OUI !
Assurez-vous de serrer la
vis qui maintient le support
de l’opérateur afin qu’il
puisse tourner librement.
FIXATION DE L’ATTACHE DU MOTEUR A LA COLONNE
Lors de l’installation du KING 24V, il est necessaire de respecter certaines mesures afin
d’obtenir un mouvement correct du vantail.
Si le poteau est en fer, il est possible de visser directement l’attache au moyen de vis
filetée M8.
si le poteau est en ciment fixer l’attache au moyen de 4 chevilles de Ø 8 mm.
En cas de mur parallèle au portail lorsque celui-ci est ouvert il est necessaire de pratiquer
une niche pour loger le motoreducteur.
NON !
FIXATION DE L’ATTACHEMENT DU MOTEUR AUX PORTAILS
Avant d’insérir le pivot dans l’attachement du portail, il faut appliquer bien du
gras.
Souder le socle à la juste hauteur (Fig. 6, 7).
Installer le KING 24V en essayant plusieurs fois d’ouvrir et de fermer en controlant que
que l’operateur ne frotte pas lorsque le portail est en mouvement.
L’opérateur ne doit
pas varier sa hauteur
pendant le mouvement.
17
F
COL
Attacco colonna
Z
Y
X
S1
Se conformer à la mesure et
faire en sorte que l’opérateur
est horizontale
45
Z
Y
X
ANT
S2
Attache vantail
Z Y
A
X
B
S3
7
MESURES A RESPECTER POUR UNE CORRECTE INSTALLATION
L
Min.÷Max
a
A
max
B
C
D
E
T
sec
ANT
COL
1÷1,80
45
100
100
815
90
14
A
S3-Y
1,81÷2,20
45
110
110
815
90
18
A
S3-X
70
140
110
815
90
20
A
S1-Z
2,51*÷3,00*
90
170
140
815
115
25
B
S2-Y
3,01*÷3,50*
115
200
140
815
115
27
B
S2-Y
B
C
D
E
ANT
COL
90
140
815
90
20
A
S1-Z
100
130
815
90
21
A
S2-Y
110
140
815
115
24
B
S1-Y
2,21÷2,50
L
Min.÷Max
90°
a
A
max
1÷1,80
1,81÷2,20
2,21÷2,50*
110°
20
*
Les vantaux de plus de 2,5 mètres de langeur
nécessitent l’installation d’une élettroserrure pou
garantir une fermeture efficace
Si le pilier est très large et n’est pas possible d’installer le
motoreducteur en respectant la mesure (B), il faut realiser une
niche dans le pilier ou deplacer le portail sur l’arete.
T
sec
ANT
Attache vantail
A
B
COL
Attache poteau
Z
Y
X
S1
MESURES DE RESPECTER AVEC DEUX ARRET MECANIQUES
L
Min.÷Max
a
1÷1,80
1,81÷2,20
2,21÷2,50
90°
2,51*÷3,00*
L
Min.÷Max
a
A
C
D
E
45
100
100
775
90
14
45
110
110
775
90
70
140
110
775
115
70
160
140
775
115
B
C
D
E
A
max
1÷1,80
1,81÷2,20
2,21÷2,50*
18
110°
T
B
max
20
ANT
COL
A
S3-Y
18
A
S3-X
20
B
S1-Z
25
B
S1-Y
ANT
COL
sec
T
sec
90
140
775
90
20
A
S1-Z
100
130
775
90
21
A
S2-Y
110
140
775
115
24
B
S1-Y
F
FARRÊT MÉCANIQUE - OPTION
Code ACG8089
Arrêt mécanique en option pour arrêter la fermeture si le portail n’est pas pourvu de
dispositif d’arrêt au sol (Fig. 8).
8
REGLAGE FINS DE COURSE MECANIQUES
Pour positionner les colliers, il est necessaire agir selon les indications du schema (Fig.
9). Pour obtenir l’ouverture desirée, il suffit de déplacer le collier (A) et de le bloquer en
vissant la vis M8 avec une clé n° 13.
Pour obtenir la fermeture desirée, il est necessarie de deplacer le collier (B) (OPTIONAL)
et de le bloquer comme indiqué ci-dessus.
9
ENTRETIEN
Effectuer seulement par personnel specialisé après avoir coupé l’alimentation.
Tous les ans, graisser les gonds et contrôler la force de poussée exercée par le
motoréducteur sur le portail.
Tous les deux ans, il est conseillé de lubrifier la vis-mère avec une graisse à base de
silicone.
10
19
F
T2 24V
T2 24V CRX
BRANCHEMENTS ÉLECTRIQUES
code AC07088
code AC07089
24Vdc 0,8A ± 15% pour ACCESSOIRES
24Vdc 0,8A ± 15% AUTOTEST pour
BARRE PALPEUSE
PIETON
PAS A PAS
SERRURE
ÉLECTRIQUE
PHOTOCELLULES
COMMUN
BARRE PALPEUSE
LED
FEU CLIGNOTANT
24Vdc 20W
R=2,2K 1/4W
ALIMENTATION
230Vac 50Hz
Fusible
T2A
TRANSFORMATEUR
COMMUN
FERMETURE
OUVERTURE
STOP
ANTENNE
ENVELOPPE
ANTENNE
M1
M2
20
F
J1
NF
Alimentation 230Vac 50/60Hz - externe à la fiche (120V/60Hz sur demande)
J2
COM.
Commun des contacts
CLOSE
Contatto impulso de fermeture (NA)
OPEN
Contatto impulso d’ouverture (NA)
STOP
Contact impulsion de stop (NC)
AERIAL
Antenne radio
SIGNAL
Voyant portail ouvert et signalisation état de fonctionnement
avec batterie et batterie déchargée (24Vdc 3W max)
A+TEST
Positif pour alimentation autotest barre palpeuse
EDGE N.C.
Contact barre palpeuse de sécurité (NC)
COM.
Commun des contacts
PHOTO N.C.
Contact photocellules (NC)
K BUTT.
Contact impulsion simple (NA)
PED. BUTT.
Contact commande ouverture piétonne (NA)
A+
Positif pour alimentation accessoires à 24Vdc
A-
Négatif pour alimentation accessoires à 24 Vdc
LOCK
Connexion électro-serrure (MAX 15W 12V)
J3
A - BRANCHEMENTS
J1
J2
J9
J10
SECONDARY
TRANSFORMER
Connecteur pour transformateur secondaire 18 Vac
J5
MOTOR 1
Connexion MOTEUR 1 (sans polarité)
J6
MOTOR 2
Connexion MOTEUR 2 (sans polarité)
SW T2 24V
Connecteur dédié à la programmation en usine. NE PAS
TOUCHER AU CAVALIER! SANS L’OPÉRATEUR, IL NE
FONCTIONNE PAS!
SW RADIO
Connecteur dédié à la programmation en usine. (seulement
pour les modèles CRX) NE PAS TOUCHER AU CAVALIER! SI
LE SYSTÈME RADIO EST ENLEVÉ, IL NE FONCTIONNE PAS!
J5
J6
J8
J9
RADIO
Module radio incorporé (modèle CRX), ou connecteur pour
radio récepteur RIB à enclenchement avec alimentation à
24Vdc
J10
BATTERY
CHARGER
Connecteur pour fiche de recharge batterie à 24Vdc (code
ACG4648)
TR1
TRIMMER RUN
Trimmer de réglage de la grande vitesse
TR2
TRIMMER LOW
SPEED
Trimmer de réglage de la basse vitesse
TR3
TRIMMER TCA
Trimmer de régulation du temps d’attendue avant avoir la
fermeture automatique (DÉFAUT DÉSHABILITÉ ET LED DL6
ÉTEINT)
B - RÉGLAGES
TRANSFORMER
FUSE 1
J4
J8
J3
J4
Connexion phase négative clignotant à 24Vdc (code
ACG7061). Attention aux polarités.
J7
F1
J7
TR3
S3
DIP 1(ON) - COMMANDE SENS DE ROTATION DU MOTEUR (POINT C)
DIP 2(ON) - PROGRAMMATION DES TEMPS (POINT D)
DIP 3
(ON) - ACTIVATION POUR LE RELACHEMENT DES PORTES PENDANT
LES PHASES DE RALLENTISSEMENT, D’OUVERTURE ET DE FERMETURE
COMPLETE (PAR RAPPORT AUX TESTS D’IMPACT SELON LA NORME
EN12453)
DIP 1-2
MEMORISATION/ANNULATION DES CODES RADIO POUR COMMANDE
OUVERTURE COMPLETE (UNIQUEMENT POUR LE MODELE CRX) (POINT E)
DIP 1-3
MEMORISATION/ANNULATION DES CODES RADIO POUR COMMANDE
OUVERTURE COMPLETE (UNIQUEMENT POUR LEMODELE CRX) (POINT F)
DIP 2-1
PROGRAMMATION DES TEMPS D’OUVERTURE PIETONNE AVEC MICROINTERRUPTEURS DE GESTION
DIP 4Photocellules toujours actives (OFF) - Photocellules actives uniquement à la
fermeture (ON)
DIP 5Pré-clignotement (ON) - Clignotement normal (OFF)
DIP 6Commande mono-impulsion (K BUTT) et récepteur radio pas-à-pas (OFF) automatique (ON)
DIP 7fonctionnement avec capteur de courant (ON-activé) Fonctionnement
préprogrammé (OFF-activé)
DIP 8Habilitation de la serrure électrique (ON-activé)
DIP 9Habilitation coup de désenclenchement de la serrure électrique (ON - activé)
DIP 10Habilitation coup d’enclenchement de la serrure électrique (ON -activé)
TR1
S3
PROG
Bouton pour la programmation
FUSE 1
T8A
Fusible de protection moteur
F1
T2A
Fusible de protection transformateur
TR2
DIP 11Habilitation du déblocage assisté (ON-activé)
DIP 12Habilitation du TEST de monitorage de la tranche de sécurité
DIP 13Sélection fonctionnement à 1 ou 2 moteurs (par défaut OFF 2 moteurs)
DIP 14Sélection du moteur KING 24V - ON
DIP 15Sélection du moteur KING 24V - OFF
DIP 16FERMETURE IMMEDIATE APRES PASSAGE DEVANT LES PHOTOCELLULES
ONACTIVEE
OFFDESACTIVEE
JP1 =>Vérifier que le cavalier est bien inséré!
JP2 =>Vérifier que le cavalier est bien inséré!
JP3 =>Vérifier que le cavalier est bien inséré!
PROG => S3 Bouton pour la programmation
REGLAGES
ATTENTION: POSITIONNER LE DIP 3 SUR ON SEULEMENT APRES AVOIR EFFECTUE
TOUTES LES PROGRAMMATIONS.
REMARQUE: AVEC DIP 3 (en position ON), LA FONCTION D’INVERSION RAPIDE DES
PORTES APRES IMPACT S’ACTIVE.
CETTE INVERSION RAPIDE DES PORTES PERMET D’ANNULER LA FORCE STATIQUE
AVANT LES 5 SECONDES INDIQUEES PAR LA NORME EN12453 ANNEXE A CHAP.
2.2 (FORCES STATIQUES ADMISSIBLES) RESPECTANT AINSI LES TESTS D’IMPACT
INDIQUES EGALEMENT PAR LADITE NORME.
DANS LE CAS OU VOUS NE POURRIEZ PAS RESPECTER LES PRESCRIPTIONS DE
LA NORME 12453, POSITIONNER LE DIP 3 SUR OFF. DANS CE CAS LES PORTES
21
F
S’ARRETERONT SANS INVERSER LE MOUVEMENT.
TRIMMER RUN (TR1) Régulateur électronique de vitesse
Avec ce trimmer il est possible de régler la vitesse du moteur (par défaut il est positionné
sur la vitesse maximale). Le réglage est très utile pour rendre l’automatisme conforme aux
normes européennes en matière d’impacts.
TRIMMER LOW SPEED (TR2) Régulateur électronique de vitesse en approche.
Le réglage de la vitesse lente s’effectue en agissant sur le trimmer LOW SPEED par
l’intermédiaire duquel il est possible de varier la tension de sortie sur le(s) moteur(s) (en
le tournant dans le sens des aiguilles d’une montre, la vitesse augmente). Le réglage est
nécessaire afin de déterminer la bonne vitesse en fin d’ouverture ainsi qu’en fin de fermeture
en fonction de la structure du portail ou en présence de légers frottements qui pourraient
compromettre le bon fonctionnement du système.
TRIMMER DE FERMETURE AUTOMATIQUE TCA (TR3) TOTALE OU PIETONNE NON
HABILITE par défaut et DEL DL6 ETEINTE (TRIMMER COMPLETEMENT REGLE DANS
LE SENS INVERSE DES AIGUILLES D’UNE MONTRE)
Avec ce trimmer, il est possible d’effectuer le réglage du temps de pause avant la fermeture
complète ou piétonne. Ce temps de pause s’active seulement avec une porte totalement ou
partiellement ouverte (piétonne) et avec la DEL DL6 allumée ( le trimmer doit être réglé dans
le sens des aiguilles d’une montre).
Le temps de pause peut varier de 2 secondes à 2 minutes, selon le réglage.
SIGNALISATIONS LED
DL1 programmation active (rouge)
DL2 portail en phase d’ouverture M2 (vert)
DL3 portail en phase de fermeture M2 (rouge)
DL4 portail en phase d’ouverture M1 (vert)
DL5 portail en phase de fermeture M1 (rouge)
DL6 signalisation temps de fermeture automatique (rouge)
DL7 contact photocellules (NC) (rouge)
DL8 contact tranche de sécurité (NC) (rouge)
DL9 commande bouton STOP (NC) (rouge)
DL10 programmation codes radio (vert)
FUSIBLES
Fuse 1 T 8A FUSIBLE DE PROTECTION DES MOTEURS
F1 T 2AFUSIBLE DE PROTECTION DU TRANSFORMATEUR (extérieur à la carte T2 24V)
C - CONTRÔLE DU SENS DE ROTATION DU/DES MOTEUR/S
1 - Mettre DIP 1 sur ON => la DEL DL1 commence à clignoter.
2 - Presser et maintenir enfoncé le poussoir PROG (le mouvement est alors effectué en
présence de l’utilisateur,, avec séquence ouvrir-stopper-fermer-stopper-ouvrir-etc.) =>
les DEL vertes DL2 et DL4 s’allument et le portail s’ouvre avec un décalage constant de
2 sec. S’il se ferme au lieu de s’ouvrir; relâcher le bouton-poussoir et inverser les deux
fils du moteur en question.
3 - A la fin de l’ouverture, relâcher le pressoir PROG et effectuer la mise au point des arrêtoirs
mécaniques d’ouverture (présents sur l’opérateur).
4 - Pousser et maintenir enfoncé le pressoir PROG => LES DEL ROUGES DL3 et DL5
s’allument et le portail se ferme avec un décalage de 2 sec.
5 - Maintenir enfoncé le pressoir PROG jusqu’à ce que le portail ne soit complètement fermé.
6 - Laisser les deux portes totalement fermées pour effectuer la programmation des temps.
7 - Repositionner DIP 1 sur OFF => la DEL DL1 s’éteint indiquant la sortie de la procédure
du contrôle.
N.B.: Pendant ce contrôle, l’arrêt d’urgence, les photocellules et les tranches de
sécurité ne sont pas activés.
D - PROGRAMMATION DES TEMPS POUR 2 MOTEURS (#) AVEC
DETECTEUR DE COURANT ACTIVE (DIP 7 ON)
PENDANT LA PROGRAMMATION LE DETECTEUR DE COURANT EST TOUJOURS ACTIF.
1 - Le portail doit être totalement fermé.
2 - Mettez le DIP 2 sur ON => la DEL DL1 émettra des clignotements brefs.
3 - Appuyez le pressoir PROG => la porte M1 s’ouvre.
4-
Une fois l’arrêtoir mécanique d’ouverture rejoint, le DETECTEUR DE COURANT
AUTOMATIQUE arrête M1 (avec mémorisation du temps et du courant) => En même
temps la porte M2 s’active et s’ouvre.
5-
Une fois l’arrêtoir mécanique d’ouverture rejoint, le DETECTEUR DE COURANT
AUTOMATIQUE arrête M2 (avec mémorisation du temps et du courant).
6 - Lorsque le pressoir PROG est enfoncé => M2 ferme.
7 - Lorsque le pressoir PROG est enfoncé => M1 ferme en déterminant l’écart de décalage
entre M2 et M1. Au même moment la DEL DL1 s’arrêtera de clignoter indiquant la fin de
la procédure d’apprentissage.
A partir de ce moment, les sécurités ou les autres commandes du portail fonctionneront
normalement (inversions, arrêt, alarmes, etc.).
8 - La fermeture des portes sera effectuée en mode rapide (et à l’approche de la fermeture
totale en mode ralenti (selon ce qui aura été établi sur le trimmer LOW SPEED)
9 - A la fermeture totale, les détecteurs de courant arrêtent le portail.
10 - A LA FIN DE LA PROGRAMMATION REMETTRE LE DIP 2 SUR OFF.
D - PROGRAMMATION DES TEMPS POUR 1 MOTEUR (M1) (#) AVEC
CAPTEUR DE COURANT ACTIVE (DIP 7 ON)
ATTENTION: POUR NE GERER QU’UN MOTEUR LE DIP 13 DOIT ETRE POSITIONNE SUR
ON. PENDANT LA PROGRAMMATION LE DETECTEUR DE COURANT EST TOUJOURS
ACTIVE.
Le portail doit être totalement fermé.
1 - Mettez DIP 2 sur ON => la DEL DL1 émettra des clignotements brefs.
2 - Appuyez sur le pressoir PROG => M1 s’ouvre.
Une fois l’arrêtoir mécanique d’ouverture rejoint, le DETECTEUR DE COURANT arrête M1
(avec mémorisation du temps et du courant).
3 - Appuyez sur le pressoir PROG => M1 se ferme.
Au même moment la DEL DL1 s’arrêtera de clignoter indiquant la fin de la procédure
d’apprentissage. A partir de ce moment, les sécurités ou les autres commandes
fonctionneront normalement (inversions, arrêts, alarmes, etc.).
A la fermeture complète, le portail s’arrête grâce au détecteur de courant.
4 - A LA FIN DE LA PROGRAMMATION REMETTRE DIP 2 SUR OFF.
(#) PENDANT LA PROGRAMMATION LES SECURITES SONT ACTIVEES ET ARRETENT
LA PROGRAMMATION (LA LED DL1, QUI CLIGNOTAIT, RESTE ALLUMEE). POUR
REPETER LA PROGRAMMATION POSITIONNER DIP 2 SUR OFF, FERMER LE PORTAIL
GRACE A LA PROCEDURE “CONTROLE SENS DE ROTATION DES MOTEURS” ET
REPETER LA PROGRAMMATION CHOISIE.
D - PROGRAMMATION DES TEMPS POUR 2 MOTEURS (#) AVEC
FONCTIONNEMENT PREPROGRAMME (DIP 7 OFF)
1 - Le portail doit être totalement fermé.
2 - Mettez le micro-interrupteur DIP 2 sur ON => la DEL DL1 clignotera rapidement.
3 - Appuyez sur le pressoir PROG => M1 s’ouvre.
4 - Une seconde après que l’arrêtoir mécanique d’ouverture a été rejoint, appuyez sur le
pressoir PROG. => M1 s’arrête et M2 s’ouvre.
5 - Une seconde après que l’arrêtoir mécanique d’ouverture a été rejoint, appuyez sur le
pressoir PROG. => M2 s’arrête.
6 - Appuyez sur le pressoir PROG => M2 se ferme.
7 - Appuyez sur le pressoir PROG => M1 se ferme en déterminant le décalage entre M2
et M1.
Au même moment la DEL DL1 s’arrêtera de clignoter indiquant la fin de la procédure
d’apprentissage.
A partir de ce moment, les sécurités ou les autres commandes du portail fonctionneront
normalement (inversions, stops, alarmes, etc.).
8 - Fini le compte à rebours le portail s’arrête.
9 - A LA FIN DE LA PROGRAMMATION REMETTRE LE DIP 2 SUR OFF.
REMARQUE: Le ralentissement est déterminé automatiquement par le tableau électronique
en phase de programmation des temps et est activé environ 50-60 cm avant
que les fins de courses mécaniques d’ouverture et de fermeture soient rejoints.
D-
PROGRAMMATION DES TEMPS POUR 1 MOTEUR (#) AVEC
FONCTIONNEMENT PREPROGRAMME (DIP 7 OFF)
ATTENTION: POUR NE GERER QU’UN SEUL MOTEUR LE DIP 13 DOIT ETRE
POSITIONNE SUR ON
1 - Le portail doit être totalement fermé.
2 - Mettez le micro-interrupteur DIP 2 sur ON => la DEL DL1 émettra des clignotements
brefs.
3 - Appuyez sur le pressoir PROG => M1 s’ouvre.
4 - Une seconde après que l’arrêtoir mécanique d’ouverture a été rejoint, appuyez sur le
pressoir PROG. => M1 s’arrête.
5 - Appuyez sur le pressoir PROG => M1 se ferme.
Au même moment la DEL DL1 s’arrêtera de clignoter indiquant la fin de la procédure
d’apprentissage.
A partir de ce moment, les sécurités ou les autres commandes du portail fonctionneront
normalement (inversions, stops, alarmes, etc.).
8 - Fini le compte à rebours le portail s’arrête.
9 - A LA FIN DE LA PROGRAMMATION REMETTRE LE DIP 2 SUR OFF.
22
F
D-
PROGRAMMATION DES TEMPS D’OUVERTURE PIETONNE (#) EN
FONCTIONNEMENT PREPROGRAMME OU AVEC DETECTEUR DE
COURANT
Une fois le portail fermé:
1 - Mettre d’abord le DIP 2 sur ON (la DEL DL1 clignote rapidement) et ensuite le DIP1 sur
ON (la DEL DL1 clignotera lentement).
2 - A ppuyer sur le bouton-pressoir piéton (COM-PED-BUTT) => M1 s’ouvre.
3 - Appuyer sur le bouton-pressoir piéton pour arrêter la course (définissant ainsi l’ouverture
de M1).
4 - A ppuyez sur le bouton-pressoir piéton pour démarrer la fermeture.
5 - A u moment de la fermeture, remettre les DIP 1 et 2 sur OFF.
(#) PENDANT LA PROGRAMMATION, LES SECURITES SONT ACTIVEES ET ARRETENT
LA PROGRAMMATION (LA DEL DL1, QUI CLIGNOTAIT, RESTE ALLUMEE).
POUR REPETER LA PROGRAMMATION, POSITIONNER LES DIP 1 ET 2 SUR OFF,
FERMER LE PORTAIL EN SUIVANT LA PROCEDURE “CONTROLE SENS DE ROTATION
DES MOTEURS” ET REPETER LA PROGRAMMATION CHOISIE.
E-
PROGRAMMATION DES CODES RADIO POUR OUVERTURE
TOTALE
(62 CODES MAXIMUM - UNIQUEMENT POUR LES MODELES CRX)
La programmation ne peut se faire que lorsque le portail est fermé.
1 - P ositionner DIP 1 sur ON, puis le DIP 2 sur ON.
2 - La DEL rouge DL1 de programmation clignote avec une fréquence de 1 sec. ON et 1 sec.
OFF pendant 10 secondes.
3 - Appuyer sur la touche de la télécommande (normalement le canal A) dans les 10
secondes. Si la télécommande est correctement mémorisée la DEL DL10 (verte) émet
un clignotement.
4 - Le temps de programmation des codes se renouvelle automatiquement pour pouvoir
mémoriser la télécommande suivante.
5 - Pour terminer la programmation, laisser s’écouler 10 sec, ou bien appuyer pendant un
moment sur le pressoir PROG. La DEL rouge DL1 de programmation arrête de clignoter.
6 - R epositionner DIP 1 sur OFF et DIP 2 sur OFF.
7 - F in de la procédure.
PROCEDURE D’EFFACEMENT DE TOUS LES CODES RADIO RESERVES A L’OUVERTURE
TOTALE
L’effacement ne peut s’effectuer que lorsque le portail est fermé.
1 - P ositionner le DIP 1 sur ON et ensuite le DIP 2 sur ON.
2 - La DEL rouge DL1 de programmation clignote avec une fréquence de 1 sec. ON et 1 sec.
OFF pendant 10 secondes.
3 - Enfoncé et maintenir appuyé le pressoir PROG pendant 5 secondes. L’effacement de la
mémoire est indiquée par deux clignotements de la DEL verte DL10.
4 - La DEL rouge DL1 de programmation reste active et il est impossible d’insérer de
nouveaux codes comme dans la procédure décrite ci-dessus.
5 - R epositionner DIP 1 sur OFF et DIP 2 sur OFF.
6 - F in de la procédure.
SIGNALISATION MEMOIRE SATUREE CODES RADIO RESERVES A L’OUVERTURE
TOTALE
La signalisation ne s’obtient que lorsque le portail est fermé.
1 - P ositionner le DIP 1 sur ON et ensuite le DIP 2 sur ON.
2 - La DEL verte DL10 clignote 6 fois, indiquant la saturation de la mémoire (62 codes
présents).
3 - Ensuite la DEL DL1 de programmation reste active pendant 10 secondes, rendant
possible l’effacement total des codes.
4 - R epositionner DIP 1 sur OFF et DIP 2 sur OFF.
5 - F in de la procédure.
F - PROGRAMMATION CODES RADIO OUVERTURE PIETONNE (62
CODES MAXIMUM - UNIQUEMENT POUR LES MODELES CRX)
1 - P ositionner DIP 1 sur ON et ensuite DIP 3 sur ON.
2 - La DEL rouge DL1 de programmation clignote avec une fréquence de 1 sec. ON et 1 sec.
OFF pendant 10 secondes.
3 - Appuyer sur la touche de la télécommande (normalement sur le canal B) dans les 10
secondes. Si la télécommande est correctement mémorisée la DEL DL10 (verte) émet
un clignotement.
4 - Le temps de programmation des codes se renouvelle automatiquement pour pouvoir
mémoriser la télécommande suivante.
5 - Pour terminer la programmation, laisser s’écouler 10 sec, ou bien appuyer pendant un
instant sur le pressoir PROG. La DEL rouge DL1 de programmation arrête de clignoter.
6 - R epositionner DIP 1 sur OFF et DIP 3 sur OFF.
REMARQUE: SI LA DEL DL1 CONTINUE DE CLIGNOTER RAPIDEMENT, CELA
SIGNIFIE QUE LE DIP 1 EST ENCORE SUR LA POSITION ON ET QUE N’IMPORTE
QUELLE MANŒUVRE SERA REFUSEE.
7 - Fin de la procédure.
PROCEDURE D’EFFACEMENT DE TOUS LES CODES RADIO RESERVES A L’OUVERTURE
PIETONNE
L’effacement ne peut s’effectuer que lorsque le portail est fermé.
1 - Positionner le DIP 1 sur ON et ensuite le DIP 3 sur ON.
2 - La DEL rouge DL1 de programmation clignote avec une fréquence de 1 sec. On et 1 sec.
OFF pendant 10 secondes.
3 - Enfoncer et maintenir appuyé le pressoir PROG pendant 5 secondes. L’effacement de la
mémoire est indiqué par deux clignotements de la DEL verte DL10.
4 - La DEL rouge DL1 de programmation reste active et il est possible d’insérer des nouveaux
codes comme dans la procédure décrite ci-dessus.
5 - Repositionner DIP1 sur OFF et DIP3 sur OFF.
6 - Fin de la procédure.
SIGNALISATION MEMOIRE SATUREE CODES RADIO RESERVES A L’OUVERTURE
PIETONNE
La signalisation ne s’obtient que lorsque le portail est fermé.
1 - Positionner le DIP 1 sur ON et ensuite le DIP 3 sur ON.
2 - La DEL verte DL clignote 6 fois indiquant la saturation de la mémoire (62 codes présents).
3 - Puis la DEL DL1 de programmation reste active pendant 10 secondes, rendant possible
l’effacement total des codes.
4 - Repositionner DIP 1 sur OFF et DIP 3 sur OFF.
5 - Fin de la procédure.
FONCTIONNEMENT DES ACCESSOIRES DE COMMANDE
ATTENTION: CONNECTER LES ACCESSOIRES A COMANDE SEULEMENT SI
IMPULSIVE.
Faire attention que des autres accessoires pour le commande (p.e. senseurs
magnétique) sont programmée avec modalité IMPULSIVE, ou contraire, le
mouvement est sans sécurité.
POUSSOIR DE COMMANDE PAS-A-PAS (COM-K BUTTON)
Si DIP 6 est sur OFF =>Il effectue une commande cyclique des commandes ouvrir stopper - fermer - stopper - ouvrir etc.
Si DIP 6 est sur ON =>
Il effectue l’ouverture, quand le portail est fermé. S’il est
actionné pendant le mouvement d’ouverture, cela ne produit
aucun effet. S’il est actionné lorsque le portail est ouvert, il le
ferme. S’il est actionné pendant la fermeture du portail, il le
rouvre.
POUSSOIR D’OUVERTURE (COM-OPEN)
Lorsque le portail est fermé, le poussoir commande le mouvement d’ouverture. S’il est
actionné pendant la fermeture du portail, il le rouvre.
FONCTION HORLOGE DU POUSSOIR D’OUVERTURE
Si vous souhaitez appliquer une horloge (ou plus simplement un commutateur)
pour ouvrir et maintenir ouverte la porte, vous devez prendre T2 24V avec fw
03 NOUP.
Si fw 03 ou supérieur ATTENTION: EN CAS DE PANNE D’UNE SÉCURITÉ, UNE
MINUTE APRÈS CETTE HORLOGE OU UN COMMUTATEUR ONT ÉTÉ ACTIVÉS, LA
PORTE S’OUVRE SANS SECURITES ACTIFS!
Cette fonction est utile dans les heures de pointe, quand la circulation est ralentie (ex.
entrée/sortie des ouvriers, urgences en zone résidentielle ou dans les parkings et,
occasionnellement, pendant les déménagements).
MODALITÉ D’APPLICATION FONCTION HORLOGE
Demander T2 24V avec firmware 02.
En connectant un interrupteur et/ou une horloge de type quotidien/hebdomadaire (à la place
ou en parallèle du poussoir d’ouverture N.O. “COM-OPEN”), il est possible d’ouvrir et de
maintenir l’automatisme ouvert tant que l’interrupteur est enfoncé ou que l’horloge reste
active.
Lorsque l’automatisme est ouvert, toutes les fonctions de commandes sont bloquées.
En relâchant l’interrupteur, ou au terme de l’heure fixée, l’automatisme se fermera
immédiatement.
POUSSOIR DE FERMETURE (COM-CLOSE)
Lorsque le portail est fermé, il commande le mouvement de fermeture.
23
F
TELECOMMANDE
Si DIP 6 est sur OFF =>Il effectue une commande cyclique des commandes ouvrir stopper - fermer - stopper - ouvrir etc.
Si DIP 6 est sur ON =>
Il effectue l’ouverture, quand le portail est fermé. S’il est
actionné pendant le mouvement d’ouverture, cela ne produit
aucun effet. S’il est actionné lorsque le portail est ouvert, il le
ferme. S’il est actionné pendant la fermeture du portail, il le
rouvre.
est activé et la DEL DL6 allumée).
S’il y a un passage rapide pendant la fermeture (par
ex. un piéton) le portail se ré-ouvrira pendant deux
secondes pour se refermer ensuite.
DIP12 OFF =>
la fermeture immédiate après passage devant les
photocellules est désactivée.
N. B. : Il est recommandé de contrôler le fonctionnement des photocellules au moins tous
les 6 mois.
BOUTON OUVERTURE PIETONNE (COM-PED-BUTT)
Commande réservée à l’ouverture partielle et à la refermeture.
Pendant l’ouverture, la pause ou la fermeture piétonne, il est possible de commander
l’ouverture depuis n’importe quelle commande raccordée à la carte T2 24V.
Par l’intermédiaire du DIP 6, il est possible de choisir le mode de fonctionnement du bouton
de commande piétonne.
Si DIP 6 est sur OFF =>Il effectue une commande cyclique des commandes ouvrir stopper - fermer - stopper - ouvrir etc.
Si DIP 6 est sur ON =>
Il effectue l’ouverture, quand le portail est fermé. S’il est
actionné pendant le mouvement d’ouverture, cela ne produit
aucun effet. S’il est actionné lorsque le portail est ouvert, il le
ferme. S’il est actionné pendant la fermeture du portail, il le
rouvre.
EDGE (BARRE PALPEUSE) (COM-EDGE)
Pendant l’ouverture, si elle est activée, elle change le mouvement en fermeture.
Pendant la fermeture, si elle est activée, elle change le mouvement en ouverture.
Si elle reste occupée après la première activation, elle effectue une nouvelle inversion après
2 secondes, pour ensuite en faire une autre plus petite et donc signaler l’alarme de barre
palpeuse en panne ou occupée (contact NO).
Si la barre palpeuse reste occupée (contact NO), aucune manutention n’est permise.
Si vous n’en utilisez pas, ponter les bornes COM-EDGE.
VERROULLAGE ELECTRIQUE (LOCK)
Mettre le DIP 8 sur ON pour activer la commande de verrouillage électrique en phase
d’ouverture.
COUP DE DESENCLENCHEMENT DE LA SERRURE ELECTRIQUE EN OUVERTURE
Mettre le DIP 9 sur ON pour activer le coup de désenclenchement de la serrure électrique en
ouverture (à condition que le DIP 8 soit sur ON).
Lorsque le portail est fermé, si une commande d’ouverture est engagée, le portail effectue
la manœuvre de fermeture pendant 0,5s et en même temps la serrure électrique est
activée(suivi par 0,5s de pause et ensuite par l’ouverture du portail).
COUP D’ENCLENCHEMENT DE LA SERRURE ELECTRIQUE
Mettre le DIP 10 sur ON pour activer le coup d’enclenchement de la serrure électrique en
phase de fermeture. Une fois la fermeture terminée, les moteurs sont commandés à pleine
tension pour garantir l’enclenchement de la serrure.
FACILITATION DU DEBLOCAGE DES MOTEURS
Mettre le DIP 11 sur ON pour activer la facilitation au déblocage manuel (à condition que le
DIP 10 soit positionné sur ON), une fois la fermeture terminée, une manœuvre d’inversion
sera exécutée avec un temps fixe de 0,2s pour faciliter le déblocage manuel.
FONCTIONNEMENT DES ACCESSOIRES DE SECURITE
MONITORAGE DES BARRES PALPEUSES DE SECURITE (A+TEST A-)
Grâce à l’entrée A+TEST et au DIP 12 en position ON, il est possible de contrôler la/les
barre(s) palpeuse(s).
Le monitorage est un Test de Fonctionnement de la barre palpeuse, exécuté à la fin de
chaque ouverture totale du portail.
Après chaque ouverture, la fermeture du portail n’est donc possible que si la/les barre(s)
palpeuse(s) ont passé le Test de Fonctionnement.
ATTENTION: LE MONITORAGE DE L’ENTREE BARRE PALPEUSE PEUT ETRE ACTIVE EN
METTANT LE DIP 12 SUR ON, OU BIEN DESACTIVE EN POSITIONNANT LE DIP 12 SUR OFF.
EN EFFET, LE TEST DE FONCTIONNEMENT N’EST POSSIBLE QUE DANS LE CAS OU IL S’AGIT
DE DISPOSITIFS DOTES DE LEUR PROPRE ALIMENTATION DE CONTROLE.
UNE BARRE PALPEUSE MECANIQUE NE PEUT ETRE MONITOREE, DONC LE DIP 12 DOIT
ETRE POSITIONNE SUR OFF.
ALARME D’AUTOTEST BARRE PALPEUSE (DIP 12 ON)
A la fin de l’ouverture, si le monitorage de la barre palpeuse a un résultat négatif, une alarme,
signalée par le clignotant qui reste allumé, intervient. Dans cette situation, la fermeture
du portail n’est pas autorisée. Il n’est possible de rétablir le fonctionnement normal qu’en
réparant la barre palpeuse et en appuyant sur une des commandes habilitées.
BOUTON DE STOP (COM-STOP)
Durant n’importe quelle opération, le bouton de STOP arrête le portail.
S’il est enfoncé quand le portail est totalement ouvert (ou partiellement en utilisant la
commande piétonne), la fermeture automatique est exclue temporairement (si elle est
habilitée par le trimmer TCA et la DEL DL6 allumée). Il faut donc effectuer une nouvelle
commande pour le qu’il se referme.
Au cycle suivant, la fonction fermeture automatique sera réactivée (si habilitée par le trimmer
TCA et la LED DL6 allumée).
PHOTOCELLULE (COM-PHOT)
DIP 4 OFF =>Si un obstacle est interposé entre les photocellules lorsque le portail est
fermé, celui-ci ne s’ouvre pas. Quand le portail est en fonctionnement, les
photocellules interviennent aussi bien pendant l’ouverture (avec reprise du
mouvement en ouverture qu’après de la libération des photocellules), que
pendant la fermeture (avec reprise du mouvement inverse qu’après de la
libération des photocellules).
DIP 4 ON =>Si un obstacle est interposé entre les photocellules lorsque le
portail est fermé et que l’ouverture est actionnée, le portail
s’ouvre (pendant l’ouverture les photocellules n’interviendront pas).
Elles n’interviendront que pendant la phase de fermeture (avec
rétablissement du mouvement inverse après une seconde même si
les photocellules sont encore occupées).
ALARME DU DETECTEUR DE COURANT
La centrale T2 24V est dotée de détecteurs automatiques qui changent le sens du portail
en cas d’impacts avec des choses ou des personnes en conformité avec les normes EN en
vigueur (toujours vérifier avec les outils appropriés le respect des valeurs imposées par la
norme), sans devoir effectuer des réglages particuliers sur la centrale, puisqu’ils sont gérés
par un logiciel interne propre.
Si après une première intervention du détecteur de courant en phase d’ouverture ou de
fermeture (seulement à grande vitesse), une seconde intervention a lieu, évidemment dans
le sens contraire, le portail s’arrête puis inverse son sens pendant 1 seconde.
L’alarme sera signalée par le clignotant qui restera actif durant une minute, pendant ce
temps, il est possible de rétablir le fonctionnement du portail en appuyant sur n’importe quel
bouton de commande.
GESTION FERMETURE IMMEDIATE APRES PASSAGE DEVANT LES PHOTOCELLULES
DIP 16 ON et DIP 4 OFF => Comme le portail s’ouvre, en passant devant les
photocellules, le portail s’arrête. Terminé de transit, après 1
seconde, le portail se ferme.
DIP 16 ON et DIP 4 ON => Comme le portail s’ouvre, en passant devant les
photocellules, le portail continue à s’ouvrir. Terminé de
transit, le portail s’arrête et après 1 seconde de pause il
invertit le mouvement en fermeture.
Si l’ouverture totale a lieu (fin du temps d’ouverture),
la fermeture immédiate est désactivée et le temps de
fermeture automatique est activé (si le trimmer TCA
TRAVAIL AVEC HOMME PRESENT, DANS LE CAS DE PANNE DE SÉCURITÉ
Si le barre palpeuse est en panne ou engagé pour plus de 5 secondes, ou si la cellule
photoélectrique est en panne ou engagée pour plus de 60 secondes, les commandes
OUVERTURE, FERMETURE, K BOUTON ET PIETONS fonctionnent seulement à homme
present.
La signalisation de l’activation de cette opération est donnée par la LED de programmation
qui clignote.
Avec cette opération est autorisée l’ouverture ou fermeture seulement en appuyant sur les
boutons de contrôle. Le contrôle radio et la fermeture automatique sont exclues parce que
leur fonctionnement n’est pas autorisé par les règles.
A la restauration du contact de sécurité, l’opération automatique ou pas à pas est restaurée
après une seconde, et donc aussi la télécommande et la fermeture automatique sont de
24
F
travail.
Note 1: A u cours de cette opération dans le cas de panne de les barres palpeuses (ou
cellules photoélectriques) les cellules photoélectriques (ou barres palpeuses) qui ne
sont pas en panne, fonctionnent encore avec l’interruption de l’opération en cours.
Note 2: L e bouton d’arrêt n’est pas considéré comme un contournement de la sécurité
dans ce mode, si il est pressé ou en panne, il ne permet pas de tout mouvement.
La manoeuvre à homme present est exclusivement une manoeuvre d’urgence
qui doit être effectuée pour des temps brefs et avec la sécurité de la vue quand
l’opérateur est en mouvement. Dès possible les protections en panne doivent être
rétablies pour un correct fonctionnement.
FEU CLIGNOTANT
N.B.: Ce tableau électronique peut alimenter QUELES FEUX CLIGNOTANTS AVEC CIRCUIT
CLIGNOTANT (ACG7061) avec ampoule de 24V et 20W maximum.
FONCTION PRE-CLIGNOTEMENT
DIP 5 - OFF => le moteur et le feu clignotant démarrent en même temps.
DIP 5 - ON => le feu clignotant démarre 3 secondes avant le moteur.
VOYANT DE SIGNALISATION PORTAIL OUVERT (COM-SIGNAL)
Il a pour tâche de signaler si le portail est ouvert, partiellement ouvert ou encore pas
totalement fermé. Il ne s’éteint que lorsque le portail est complètement fermé. Pendant la
programmation, cette signalisation est active.
N.B.: Maximum 3 W. Si la consommation des boîtiers de commande ou des ampoules
dépasse ce seuil, la logique du tableau électronique en sera compromise, engendrant un
possible blocage des opérations.
FONCTIONNEMENT APRES COUPURE DE COURANT (SANS PILES)
Au retour de la courant la led DL1 s’allume et reste allumée pendant tout le temps que le
portail reste ouvert. Elle s’éteindra à la complète fermetre du portail. Il est conseillé d’ouvrir
complètement le portail. Laissez le portail se fermer tout seul avec la fermeture automatique
ou attendez que le feu clignotant arrête de clignoter avant de commander la fermeture.
Cette opération permettra au portail de se réaligner. En effet, si les moteurs se sont bloqués
et ont été déplacés de la position normale de fermeture pendant la coupure de courant, la
première manœuvre au retour de l’alimentation doit être complète.
Si le black-out se passe pendant le mouvement, ou avec le portail ouvert, et la première
commande est celle de fermeture, la fermeture se passera avec déphasage totale des
portes donc M2 se fermera avant et M1 se fermera après. Le mouvement separé des deux
moteurs évitera que les portes se touchent.
CARACTERISTIQUES TECNIQUES
- Intervalle de température
0 ÷ 55°C
- Humidité< 95% sans condensation
- Tension d’alimentation 230V~ ± 10%
(120/60 Hz sur demande)
- Fréquence
50/60 Hz
- Alimentation batterie
20-24VCC
- Puissance du transformateur
130VA
primaire 230Vac
secondaire 18Vac
- Consommation maximale
50 mA
- micro-interrupteurs de réseau 100ms
- Puissance maximale voyant portail ouvert24Vdc 3W (équivalent à une
petite lampe de 3W ou à 5
DEL avec résistance en série
de 2,2 k ohm)
- Charge maximale feu clignotant
24Vdc 20W
- Courant disponible pour photocellules et accessoires
1A ±15%
- Courant disponible sur le connecteur radio
200mA
CARACTERISTIQUES TECHNIQUES RADIO (modèle T2 24V crx)
- Fréquence réception 433,92MHz
- Impédance
52 OHM
- Sensibilité
>2,24µV
- Temps d’excitation
>2,24µV
- Temps de désexcitation
300ms
- Toutes les entrées doivent être utilisées avec des contacts propres car l’alimentation est
générée à l’intérieur de la carte (tension sûre) pour garantir le respect de la double isolation
et de l’isolation renforcée par rapport aux parties sous tension dangereuse.
- Les éventuelles connexions de circuits externes aux sorties du tableau électronique doivent
être faites pour garantir la double isolation ou l’isolation renforcée par rapport aux parties
sous tension dangereuse.
-
Toutes les entrées sont gérées par un circuit programmé intégré qui exécute un
autocontrôle à chaque mise en route.
SOLUTION DES PROBLEMES
Après avoir effectué tous les raccordements en suivant attentivement le schéma et avoir
positionné le portail en position intermédiaire, vérifier l’allumage correct des leds rouges
DL7, DL8 et DL9.
Si les leds ne s’allument pas, en maintenant toujours le portail en position intermédiaire,
vérifier les points ci-après et éventuellement remplacer les composants qui ne fonctionnent
pas.
DL7 éteinte Photocellules en panne
DL8 éteinteBande de contact de sécurité en panne (Si la bande de contact n’est pas
reliée, effectuer la connexion entre COM et EDGE)
DL9 éteinteBouton de STOP en panne (Dans le cas où le STOP n’est pas connecté,
ponter entre COM et STOP).
Durant le fonctionnement avec opérateur présent, avec DIP n° 1 sur ON, vérifier que durant
l’ouverture de M1 et M2, les leds vertes DL2 et DL4 s’allument, et que durant la fermeture
de M1 et M2, les leds rouges DL3 et DL5 s’allument.
DEFAUT
SOLUTION
Après avoir effectué les différents raccordements et avoir allumé le courant,
toutes les leds sont éteintes.
Vérifier l’intégrité des fusibles F1, FUSE 1.
En cas de fusible hors service, ne remplacer qu’avec des fusibles de valeur adéquate
F1 T 2AFUSIBLE DE PROTECTION TRANSFORMATEUR (extérieur à la carte T2 24V)
FUSE 1 8A FUSIBLE DE PROTECTION MOTEURS
Le moteur ouvre et ferme, mais n’a pas de force et se déplace lentement.
Vérifier le réglage des trimmers RUN et LOW-SPEED.
Le portail effectue l’ouverture, mais ne se referme pas après le temps
configuré.
S’assurer que le trimmer TCA est habilité avec la DEL DL6 allumée.
Si le bouton OPEN est toujours enfoncé, remplacer le bouton ou le boîtier de commande OPEN. Si l’autotest
de la barre palpeuse est négatif, vérifier les connexions entre le tableau électronique et l’alimentation de la/
des barre(s) palpeuse(s). Attention: Si vous n’utilisez pas un boîtier d’alimentation pour la barre palpeuse, le
DIP 12 doit être positionné sur OFF.
Le portail ne s’ouvre pas et ne se referme pas en actionnant les différents Contact bande de contact de sécurité en panne. Contact photocellules en panne avec DIP 4 OFF. Replacer
boutons K, Radio, Open et Close.
ou remplacer le contact correspondant.
La serrure électrique ne fonctionne pas.
S’assurer d’avoir activé le DIP 8 sur ON.
La DEL DL1 clignote rapidement et aucune manutention n’est habilitée.
Positionner les DIP switch 1, 2 ou 3 sur OFF.
25
F
OPTIONS
Pour les branchements et les données techniques des accessoires, se conformer aux livrets d’instruction correspondants.
EMETTEUR RADIO SUN
SUN 2CH
SUN CLONE 2CH
code ACG6052
code ACG6056
SUN 4CH
SUN CLONE 4CH
code ACG6054
code ACG6058
FICHE DE CHARGE BATTERIE
BATTERIE
code ACG4648
Batterie 2,2Ah 12V
code ACG9515
DISPOSITIFS Wi-Fi
MASTER Wi-Fi
FICHE DE GESTION SYSTÈME SANS FILS
embrochable - 12÷30V ac/dc
avec bornes à visser - 12÷30V ac/dc
code ACG6094
code ACG6099
NOVA Wi-Fi
PHOTOCELLULES SANS FILS
PAIRE DE POTEAUX NOVA
VERTIGO Wi-Fi
code ACG8037
code ACG8039
PHOTOCELLULES SANS FIL POUR REMPLACER LA BARRE PALPEUSE
VERTIGO Wi-Fi 8 code ACG8042 - VERTIGO Wi-Fi 10 code ACG8043
SPARK Wi-Fi
BLOCK Wi-Fi
SÉLECTEUR À CLÉ SANS FILS
code ACG6098
FEU CLIGNOTANT SANS FILS
SUPPORT LATERAL
code ACG7064
code ACG7042
G
B
SYSTEM LAY-OUT
❸
❷
TECHNICAL FEATURES
KING 24V is a irreversible operator suitable for opening gates with a leaf length
of up to 4 metres (Fig. 1).
The KING 24V operator use mechanical stoppers, thus avoiding the need for
electrical limit switches.
❹
KING 24V
TECHNICAL DATA
❶
❺
❶
❺ ❹
Max. leaf length
m
4
Max. leaf weight
kg
400
Max. travel
mm
Average opening time
s.
14÷27
Operating speed
m/s.
0,0125
Thrust force
N
1800
EEC Power supply
24V
24V
Motor capacity
W
118
Power absorbed
A
5,4
Daily operations suggested
n°
Service
1 - KING 24V operator
2 - Tuned aerial
3 - Flashing lamp
4 - Key selector
5 - Photoelectric cells (external)
150
90%
Guaranteed consecutive cycles
1
345*
n°
Grease
200/14s
Bechem - RHUS 550
Weight of electroreducer
kg
10
Noise
db
<70
Volume
m3
0,0184
Operating Temperature
°C
-10 ÷ +55°C
Protection
IP
44
* With incorporated mechanical stop that cuts in during opening. - If the mechanical stop
is used during closing (optional), the maximum travel is reduced by 50 mm.
BLACK 1
Connect to J5 or J6 terminal +
BLACK 2
Connect to J5 or J6 terminal Measurements in mm
27
2
G
B
INSTALLATION
PRE-INSTALLATION CHECKS
The leaf must be fixed firmily on the hinges to the pillars, must not be flexible during the
movement and must move without frictions.
Before the installation of KING 24V, verify all dimensions etc.
There’s no need for any modification, if the gate is like that shown in Fig. 1.
Gate features must be uniformed with the standards and laws in force. The gate
can be automated only if it is in a good condition and its conditions comply with the EN
12604 norm.
- The gate leaf does not have to have a pedestrian opening. In the opposite case it
is necessary to take the appropriate steps, in accordance with EN 12453 norm (for
instance; by preventing the operation of the motor when the pedestrian opening is
opened, by installing a safety microswitch connected with the control panel).
- No mechanical stop shall be on top of the gate, since mechanical stops are not safe
enough.
3
Parts to install meeting the EN 12453 standard
USE OF THE SHUTTER
Skilled persons
(out of public
area*)
Skilled persons
(public area)
Unrestricted
use
A
B
non possibile
with visible impulses
(e.g. sensor)
C or E
C or E
C and D, or E
with not visible impulses
(e.g. remote control
device)
C or E
C and D, or E
C and D, or E
C and D, or E
C and D, or E
C and D, or E
COMMAND TYPE
with manned operation
automatic
4
* a typical example are those shutters which do not have access to any public way
A: Command button with manned operation (that is, operating as long as activated),
like code ACG2013
B: Key selector with manned operation, like code ACG1010
C: Adjustable power of the motor
D: Safety strips and/or other safety devices to keep thrust force within the limits of
EN12453 regulation - Appendix A.
E: Photocells, like code ACG8026 (To apply every 60÷70cm for all the height of the
column of the gate up to a maximum of 2,5m - EN 12445 point 7.3.2.1)
5
Grease
thoroughly
6
EMERGENCY RELEASE
To move the gate manually it is necessary to release the operator inserting the special
key and turning it 2 times in the anti-clockwise sense (Fig. 3).
In order to carry out the manual operation of the gate leaf the followings must be checked:
- That the gate is endowed with appropriate handles;
- That these appropriate handles are placed so to avoid safety risks for the operator;
- That the physical effort necessary to move the gate leaf should not be higher than 225
N, for doors/gates for private dwellings, and, 390N for doors/gates for commercial and
industrial sites ( values indicated in 5.3.5 of the EN 12453 norm).
YES !
Be sure to tighten the bolt
that holds the bracket to
the operator so that it can
rotate freely.
FIXING THE ACTUATOR ATTACHMENT TO THE COLUMN
To obtain a correct movement of the leaf gate it is necessary to respect the measures.
In case an iron pillar is available, weld the bracket straight to it.
In case you need to fix the bracket onto a concrete pillar, use the fixing plate as shown
in picture 4, to be fastened with 4 Fischer screws of Ø 8 mm.
In the case you have a wall parallel with the open gate, you must provide a niche in which
to place the operator.
NO !
The operator must not
vary its height during the
movement.
FIXING THE ACTUATOR ATTACHMENT TO THE GATE
Before inserting the pin into the gate attachment, grease thoroughly.
Weld the base at the right height (Fig. 6, 7).
Fix the KING 24V and try several times to open and to close the gate, controlling that the
operator does not touch the moving gate.
28
G
B
COL
Column attachment
Z
Y
X
S1
Comply with the measure and
make sure that the operator is
horizontal
45
Z
Y
X
ANT
S2
Leaf attachment
A
Z Y
X
B
S3
7
RESPECT THE MEASURES FOR A CORRECT INSTALLATION
L
Min.÷Max
a
A
max
B
C
D
E
T
sec
ANT
COL
1÷1,80
45
100
100
815
90
14
A
S3-Y
1,81÷2,20
45
110
110
815
90
18
A
S3-X
70
140
110
815
90
20
A
S1-Z
2,21÷2,50
90°
2,51*÷3,00*
90
170
140
815
115
25
B
S2-Y
3,01*÷3,50*
115
200
140
815
115
27
B
S2-Y
B
C
D
E
ANT
COL
L
Min.÷Max
a
A
max
1÷1,80
1,81÷2,20
2,21÷2,50*
110°
20
T
sec
90
140
815
90
20
A
S1-Z
100
130
815
90
21
A
S2-Y
110
140
815
115
24
B
S1-Y
* In the case of leaf longer than 2,5 metres, an electric
lock must be fitted to ensure efficient closing.
If the pillar is too large, and it is not possible to adjust the
actuator respecting the measure (B), you must make a niche in
the pillar or you have to move the gate to the edge of the pillar.
ANT
Leaf attachment
A
B
COL
Column attachment
S1
RESPECT THE MEASURES WITH 2 MECHANICAL STOPPERS
L
Min.÷Max
a
1÷1,80
1,81÷2,20
2,21÷2,50
90°
2,51*÷3,00*
L
Min.÷Max
a
A
C
D
E
45
100
100
775
90
14
45
110
110
775
90
70
140
110
775
115
70
160
140
775
115
B
C
D
E
A
max
1÷1,80
1,81÷2,20
2,21÷2,50*
29
110°
T
B
max
20
ANT
COL
A
S3-Y
18
A
S3-X
20
B
S1-Z
25
B
S1-Y
ANT
COL
sec
T
sec
90
140
775
90
20
A
S1-Z
100
130
775
90
21
A
S2-Y
110
140
775
115
24
B
S1-Y
G
B
MECHANICAL STOP - OPTIONAL
Code ACG8089
Optional mechanical stop to stop closing, if the gate is not fitted with a floor stop (Fig. 8).
8
MECHANICAL STOPPER ADJUSTMENT
To adjust the stoppers you have to follow the scheme (Fig. 9).
To set the opening limit it’s enough to fix the stopper (A) in the needed position by
tightening the 8mA screw with a n. 13 key.
To obtain the desired closing limit you must adjust the stopper (B) (OPTIONAL) ) in the
needed position and tighten it as for stopper (A).
9
MAINTENANCE
To be undertaken only by specialized staff after disconnecting power supply.
Lubricate the hinges and check the oil level and thrust force generated by the operator
on the gate once a year.
Lubricate the nut screw with silicon grease every two years.
10
30
T2 24V
T2 24V CRX
ELECTRIC CONNECTIONS
code AC07088
code AC07089
24Vdc 0,8A ± 15% for ACCESSORY SUPPLY
24Vdc 0,8A ± 15% for AUTOTEST SAFETY STRIPS
PEDESTRIAN
STEP BY STEP
ELECTRIC
LOCK
PHOTOCELLS
COMMON
SAFETY STRIPS
LED
BLINKER
24Vdc 20W
R=2,2K 1/4W
POWER SUPPLY
230Vac 50 Hz
FUSE
T2A
TRANSFORMER
COMMON
CLOSE
OPEN
STOP
ANTENNA
ANTENNA
BRAIDING
M1
M2
31
G
B
G
B
J1
NF
Power supply 230 Vac 50/60 Hz - external to the
control panel - (120V/60Hz upon request)
J2
COM.
Common contact
CLOSE
Closing impulse contact (NA)
OPEN
Opening impulse contact (NA)
STOP
STOP impulse contact (NC)
AERIAL
Radio Antenna
SIGNAL
Gate open state and battery state output indicator
(24Vdc 3W max)
A+TEST
+ 24Vdc safety strip self-test power supply
EDGE N.C.
Safety strip contact (NC)
COM.
Common contact
PHOTO N.C.
Photocells contact (NC)
K BUTT.
Single pulse contact (NO)
PED. BUTT.
Pedestrian opening contact (NA)
A+
+ 24Vdc accessories power supply
A-
- 24Vdc accessories power supply
LOCK
Electric lock connection (MAX 15W 12V)
J3
A - CONTROL PANEL FEATURES
J2
J3
TRANSFORMER
FUSE 1
J9
J10
J5
J6
J8
J4
SECONDARY
TRANSFORMER
Connection to secondary coil of transformer 18 Vac
J5
MOTOR 1
MOTOR 1 CONNECTION (without polarity)
J6
MOTOR 2
MOTOR 2 CONNECTION (without polarity)
SW T2 24V
Connector dedicated to the factory programming.
DO NOT REMOVE ANY JUMPER! OTHERWISE THE
OPERATOR WILL NOT WORK!
J7
SW RADIO
Connector dedicated to the factory programming (only
CRX control board) DO NOT REMOVE ANY JUMPER!
OTHERWISE THE OPERATOR WILL NOT WORK!
S3
J8
F1
J4
- 24Vdc blinker (code ACG7061) power supply. Pay
attention to the polarity.
J7
J1
TR3
J9
RADIO
Built-in radio module (model CRX), or connector for
radio receiver RIB, 24 Vdc supply
J10
BATTERY CHARGER
Connector for charge card of 24Vdc battery (code
ACG4648)
TR1
TRIMMER RUN
Trimmer for high speed adjustment operations
TR2
TRIMMER LOW SPEED
Trimmer for low speed adjustment operations
S3
PROG
Programming button
TR3
TRIMMER TCA
Trimmer for automatic closing time adjustment
(DISABLED DEFAULT AND DL6 LED OFF)
FUSE 1
T8A
Motor protection fuse
F1
T2A
Transformer protection fuse
TR1
32
TR2
G
B
B - SETTINGS
DIP 1
DIP 2
DIP 3
(ON) - MOTOR ROTATION DIRECTION CONTROL (POINT C)
(ON) - TIMER (POINT D)
(ON) - ACTIVATES DOOR RELEASE DURING PHASES OF SLOWDOWN AND
TOTAL OPENING AND CLOSING (AS PER THE IMPACT TESTS OF EN12453)
DIP 1-2 MEMORIZATION/CANCELLATION OF RADIO CONTROL CODES FOR TOTAL
OPENING (ONLY MODEL CRX) (POINT E)
DIP 1-3 MEMORIZATION/CANCELLATION OF RADIO CONTROL CODES FOR
PEDESTRIAN OPENING (ONLY MODEL CRX) (POINT F)
DIP 2-1 MICRO-SWITCH CONTROLLER FOR PEDESTRIAN OPENING TIMER
DIP 4Photocells always active (OFF) - Photocells active only during closing (ON)
DIP 5 Pre-blinking (ON) - Normal blinking (OFF)
DIP 6Single pulse command (K BUTT) and step-by-step radio receiver (OFF) - automatic
(ON)
DIP 7Power sensor operation (ON-activated) time operation (OFF-activated).
DIP 8 Electric lock activation (ON-activated)
DIP 9 Electric lock pulse release (ON-activated)
DIP 10 Electric lock pulse engagement (ON-activated)
DIP 11 Easy release activation (ON-activated)
DIP 12 Sensor TEST activation (ON-activated).
DIP 13 Selection of 1 or 2 motor operation (default OFF 2 motors)
DIP 14 KING 24 - ON
DIP 15 KING 24 - OFF
DIP 16 IMMEDIATE CLOSING AFTER PASSING IN FRONT OF PHOTOCELLS
ONACTIVATED
OFFDEACTIVATED
JP1 => Check that the jumper is inserted!
JP2 => Check that the jumper is inserted!
JP3 => Check that the jumper is inserted!
photocell contact (NC) (red)
sensor contact (NC) (red)
STOP button (NC) (red)
radio code program (green)
FUSES
Fuse 1 T 8A MOTOR PROTECTION FUSE
F1 T 2ATRANSFORMER PROTECTION FUSE (on the outside of the T2 24V board)
C - MOTOR ROTATIONAL DIRECTION CONTROL
1 - Set DIP 1 to ON => LED DL1 starts flashing.
2 - Press and hold the PROG button. (movement is now manually controlled - open-stopclose-stop-open - etc.) => GREEN LEDS DL2 and DL4 are lit and the gate panels open
with a fixed lag of 2 sec. If they close instead of open, release the button and reverse the
two wires on the motor used.
3 - After opening release the PROG button and calibrate the mechanical opening stops (on
the operator).
4 - Press and hold the PROG button => RED LEDs DL3 and DL5 turn on and the gate panels
close with a time lag of 2 sec.
5 - Continue to hold the PROG button until the gate is completely closed.
6 - Leave the two doors completely closed to set the timer.
7 - Reset DIP1 to OFF => LED DL1 turns off, signaling exit from control.
N.B.: During this check the stop, the photocells and the sensors are not active.
D - SETTING THE TIMER FOR 2 MOTORS (#) WITH POWER SENSOR
ACTIVATED (DIP 7 ON)
PROG => S3 Programming button
ADJUSTMENTS
ATTENTION: PUT DIP 3 IN THE ON MODE ONLY AFTER HAVING CARRIED OUT ALL THE
PROGRAMMING PROCEDURES.
NOTE: WITH DIP 3 (ON) BRIEF GATE REVERSAL AFTER IMPACT IS ACTIVATED.
THIS BRIEF GATE REVERSAL PERMITS STATIC FORCE TO BE REDUCED TO ZERO
WITHIN 5 SECONDS AS PER STANDARD EN12453 POINT A.2.2 (ACCEPTABLE STATIC
FORCE), THEREBY COMPLYING WITH THE IMPACT TESTS ALSO OUTLINED BY
EN12453).
IF COMPLIANCE WITH THE AFOREMENTIONED STANDARD IS UNNECESSARY, SIMPLY
POSITION DIP 3 TO OFF. IN THIS CASE THE GATES STOP WITHOUT REVERSING.
RUN TRIMMER (TR1) high-speed electronic regulator
This trimmer permits motor speed adjustment (the default setting is maximum speed).
Adjustment of the automation is useful for compliance with European impact standards.
LOW-SPEED TRIMMER (TR2) Electronic slow speed approach control
The slow speed control is performed by adjusting the LOW- SPEED TRIMMER which changes
the voltage output across the motor(s) (turning it clockwise increases the speed). Adjustment
is performed to determine the correct speed at the end of opening and closing according to
the gate or when there is friction that might cause the system to function poorly.
AUTOMATIC CLOSING TRIMMER - TCA (TR3) TOTAL OR PEDESTRIAN default NOT
ACTIVATED and LED DL6 OFF (TRIMMER FULLY ROTATED COUNTERCLOCKWISE)
This trimmer makes it possible to adjust the time for total or pedestrian automatic closing.
Only with gate completely (total) or partially (pedestrian) open and LED DL6 on (trimmer
rotated clockwise).
The pause time can be adjusted from a minimum of two seconds up to a maximum of two
minutes.
LED SIGNALS
DL1 program activated (red)
DL2 gate opening M2 (green)
DL3 gate closing M2 (red)
DL4 gate opening M1 (green)
DL5 gate closing M1 (red)
DL6 automatic closing indicator (red)
DL7
DL8
DL9
DL10
WHILE SETTING THE TIMER THE POWER SENSOR IS CONTINUOUSLY ACTIVATED.
1 - The gate must be completely closed.
2 - Set DIP 2 to ON => LED DL1 will blink rapidly.
3 - Press the PROG button. => M1 opens.
4 - When the mechanical opening stop is reached, the AUTOMATIC POWER SENSOR stops
M1 (memorizing the time and the power) => At the same time M2 is triggered to open.
5 - When the mechanical opening stop is reached, the AUTOMATIC POWER SENSOR stops
M2 (memorizing the time and the power).
6 - Press the PROG button. => M2 closes.
7 - Press the PROG button. => M1 closes and sets the lag time between M2 and M1. At
the same time LED DL1 stops flashing indicating exit from the programming procedure.
Safety and other gate commands now operate normally (inversions, stop, alarms, etc.).
8 - The gate panels will close in high-speed mode (depending on how you set the RUN
trimmer) and near total closure in the slow mode (depending on how you set the LOWSPEED trimmer).
9 - Upon closing the power sensors stop the gate.
10 - AFTER PROGRAMMING RESET DIP 2 TO OFF.
D - SETTING THE TIME FOR ONE MOTOR (M1) (#) WITH POWER
SENSOR ACTIVATED (DIP 7 ON)
CAUTION: FOR ONE MOTOR CONTROL DIP 13 MUST BE POSITIONED TO ON; DURING
PROGRAMMING THE POWER SENSOR IS CONTINUOUSLY ACTIVE.
The gate must be completely closed.
1 - Set DIP 2 to ON => LED DL1 will blink rapidly.
2 - Press the PROG button. => M1 opens.
When the mechanical opening stop is reached, the AUTOMATIC POWER SENSOR stops
M1 (memorizing the time and the power).
3 - Press the PROG button. => M1 closes.
At the same time LED DL1 stops flashing indicating exit from programming. Safety and
other gate commands now operate normally (inversions, stop, alarms, etc.).
Upon closing the power sensor stops the gate.
4 - AFTER PROGRAMMING RESET DIP 2 TO OFF.
(#) DURING PROGRAMMING THE SAFETY DEVICES ARE ACTIVE AND STOP THE
PROGRAMMING PROCEDURE (LED DL1 FROM FLASHING BECOMES CONSTANT).
TO REPEAT PROGRAMMING SET DIP 2 TO OFF, CLOSE THE GATE USING THE
PROCEDURE “MOTOR ROTATIONAL DIRECTION CONTROL” AND REPEAT THE
DESIRED PROGRAMMING PROCEDURE.
33
G
B
D - SETTING THE TIME FOR 2 MOTORS (#) WITH TIME OPERATION
(DIP 7 OFF)
1 - The gate must be completely closed.
2 - Set DIP 2 to ON => LED DL1 will blink rapidly.
3 - Press the PROG button. => M1 opens.
4 - When the mechanical opening stop is reached, wait a second then press the PROG button
=> M1 stops and M2 opens.
5 - When the mechanical opening stop is reached => wait 1 second and press the PROG
button => M2 stops.
6 - Press the PROG button => M2 closes.
7 - Press the PROG button => M1 closes setting the time lag between M2 and M1.
At the same time LED DL1 stops flashing indicating exit from the programming
procedure.
Safety and other gate commands now operate normally (inversions, stop, alarms, etc.).
8 - After the set amount of time, the gate will stop.
9 - AT THE END OF PROGRAMMING RESET DIP 2 TO OFF.
NOTE: The slowdown is automatically determined by the control board during the time setting
phase and is activated at about 50 to 60 cm before reaching the mechanical opening or
closing limit.
D - SETTING THE TIME FOR 1 MOTOR (#) WITH TIME OPERATION
(DIP 7 OFF)
CAUTION: FOR ONE MOTOR CONTROL DIP 13 MUST SET TO ON
1 - The gate must be completely closed.
2 - Set micro-switch DIP 2 to ON => LED DL1 will blink rapidly.
3 - Press the PROG button => M1 opens.
4 - When the mechanical opening stop is reached, wait a second then press the PROG button
=> M1 stops.
5 - Press the PROG button => M1 closes.
At the same time LED DL1 stops flashing indicating exit from the programming
procedure.
Safety and other gate commands now operate normally (inversions, stop, alarms, etc.).
6 - After the set amount of time, the gate will stop.
7 - AT THE END OF PROGRAMMING RESET DIP 2 TO OFF.
D - SETTING PEDESTRIAN OPENING TIMES (#) BOTH FOR TIME AND
POWER SENSOR OPERATION
With gate closed:
1 - First set DIP2 to ON (LED DL1 flashes quickly) and then DIP1 to ON ( LED DL1 flashes
slowly).
2 - Push the pedestrian button (COM-PED.BUTT) => M1 opens.
3 - Push the pedestrian button to stop movement (thereby setting M1 opening).
4 - Push the pedestrian button to start closing.
5 - Upon closing reset DIP 1 and 2 to OFF.
(#) DURING PROGRAMMING THE SAFETY DEVICES ARE ACTIVE AND STOP THE
PROGRAMMING PROCEDURE (LED DL1 FROM FLASHING BECOMES CONSTANT).
TO REPEAT PROGRAMMING SET DIP 2 TO OFF, CLOSE THE GATE USING THE
PROCEDURE “MOTOR ROTATIONAL DIRECTION CONTROL” AND REPEAT THE
DESIRED PROGRAMMING PROCEDURE.
E-R
ADIO CODE PROGRAMMING FOR TOTAL OPENING
(UP TO 62 CODES - CRX MODELS ONLY)
Programming can be done only when the gate is stationary.
1 - First set DIP 1 to ON and then DIP 2 to ON.
2 - The red LED DL1 flashes ON every 1 sec. and OFF for 10 seconds.
3 - Press the remote control button (usually channel A) within the allotted 10 seconds. If the
remote is memorized properly LED DL10 (green) blinks.
4 - The programming time for codes is automatically renewed in order to memorize the next
remote control.
5 - To finish programming, wait 10 seconds, or press the PROG button briefly. The red LED
DL1 stops flashing.
6 - Reset DIP 1 to OFF and DIP 2 to OFF.
7 - End of procedure.
CANCELLATION OF ALL RADIO CODES FOR TOTAL OPENING
Cancellations can only be performed when gate is stationary.
1 - Set DIP 1 to ON and then DIP 2 to ON.
2 - The red LED DL1 flashes ON every 1 second and OFF for 10 seconds.
3 - Press and hold the PROG button for 5 seconds. Memory cancellation is indicated by two
flashes of green LED DL10.
4 - The red LED DL1 remains active and you can add new codes as shown above.
5 - Reset DIP 1 to OFF and DIP 2 to OFF.
6 - End of procedure.
INDICATOR MEMORY FULL OF RADIO CODES FOR TOTAL OPENING
Indication only when gate is stationary.
1 - Set DIP 1 to ON and then DIP 2 to ON.
2 - The green LED DL10 flashes 6 times when the memory is full (62 codes).
3 - LED DL1 will then remain active for 10 seconds enabling possible cancellation of codes.
4 - Reset DIP 1 to OFF and DIP 2 to OFF.
5 - End of procedure.
F - PROGRAMMING PEDESTRIAN OPENING RADIO CODES
(UP TO 62 CODES - CRX MODELS ONLY)
Programming can be done only when the gate is stationary.
1 - Set DIP 1 to ON and then DIP 3 to ON.
2 - The red led DL1 flashes ON for 1 second and OFF for 1 second for 10 seconds.
3 - Press the remote control button (usually channel B) within the allotted 10 seconds. If the
remote is properly memorized LED DL10 (green) blinks.
4 - The programming time for codes is automatically renewed in order to memorize the next
remote control.
5 - To finish programming wait 10 seconds, or press the PROG button briefly. The red LED
DL1 stops flashing.
6 - Reset DIP 1 to OFF and DIP 3 to OFF.
NOTE: If LED DL1 CONTINUES BLINKING QUICKLY IT MEANS THAT DIP 1 IS STILL
SET TO ON AND THAT ANY OPERATION IS REFUSED.
7 - End of procedure.
CANCELLATION PROCEDURE FOR ALL PEDESTRIAN OPENING RADIO CODES
Cancellation can only be performed when the gate is stationary.
1 - Set DIP 1 to ON and then DIP 3 to ON.
2 - The red LED DL1 flashes ON for 1 second and OFF for 1 second for 10 seconds.
3 - Press and hold the PROG button for 5 seconds. Memory cancellation is indicated by two
flashes of green LED DL10.
4 - The red LED DL1 remains active and you can add new codes as shown above.
5 - Reset DIP 1 to OFF and DIP 3 to OFF.
6 - End of procedure.
INDICATION MEMORY FULL OF PEDESTRIAN OPENING RADIO CODES
Indication only when the gate is stationary.
1 - Set DIP 1 to ON and then DIP 3 to ON.
2 - The green LED DL10 flashes 6 times when the memory is full (62 codes).
3 - The LED DL1 will then remain active for 10 seconds enabling possible cancellation of
codes.
4 - Set DIP 1 to OFF and DIP 3 to OFF.
5 - End of procedure.
CONTROL ACCESSORIES OPERATION
ATTENTION: ONLY IMPULSIVE COMMANDS HAVE TO BE CONNECTED.
Make sure that any other type of command accessories (e.g. mass detectors)
used on the installation are set in the IMPULSIVE mode, otherwise, the gate
will be operated even without the protection of the safety devices.
STEP-BY-STEP BUTTON (COM-K BUTTON)
If DIP 6 OFF =>It cyclically performs the commands open-stop-close-stop-open etc.
If DIP 6 ON =>Opens the gate when closed. There is no effect if activated while opening.
If activated when gate is open, the gate closes. If activated while closing,
the gate reopens.
OPEN BUTTON (COM-OPEN)
The button controls the opening movement when the gate is stationary. If activated while
closing, it reopens the gate.
CLOCK FUNCTION OF OPEN BUTTON
If you want to apply a clock (or more simply a switch) to open and keep open
the gate, you have to take T2 24V with fw 03 NOUP.
If fw 03 or higher ATTENTION: IN CASE OF FAILURE OF ONE SAFETY, ONE
MINUTE AFTER THAT CLOCK OR SWITCH HAVE BEEN ACTIVATED, THE GATE
WILL OPEN WITHOUT SAFETIES ACTIVE!
This function is useful during peak hours, when vehicle traffic is slow (e.g. entry/exit of
workers, emergencies in parking or residential areas and, temporarily, for moving operations).
34
34
G
B
CLOCK FUNCTION APPLICATION
It is necessary to request a T2 24V control panel with firmware 02.
By connecting a switch and/or a daily/weekly clock (instead of or in parallel to the open
button N.O. “COM-OPEN”), you can open and keep the automation open for as long as the
switch is pressed or the clock remains active. Command functions are inoperative with open
automation.
Releasing the switch or at the preset time, the automation closes immediately.
CLOSE BUTTON (COM-CLOSE)
Controls the closing movement when the gate is stationary.
REMOTE CONTROL
If DIP 6 OFF =>It cyclically performs the commands open-stop-close-stop-open etc.
If DIP 6 ON =>Opens the gate when closed. There is no effect if activated while opening.
If activated when gate is open, the gate closes. If activated while closing,
the gate reopens.
PEDESTRIAN OPEN BUTTON (COM-PED.BUTT.)
Partial opening and closing control.
During pedestrian opening, pausing or closing, you can control the opening of any command
linked to the T2 24V board.
With DIP 6 you can choose the operation mode of the pedestrian push button.
If DIP 6 OFF =>It cyclically performs the commands open-stop-close-stop-open etc.
If DIP 6 ON =>Opens the gate when closed. There is no effect if activated while opening.
If activated when gate is open, the gate closes. If activated while closing,
the gate reopens.
ELECTRIC LOCK (LOCK)
Set DIP 8 to ON to enable control of the electric lock when opening.
ELECTRIC LOCK PULSE RELEASE IN OPENING
Set DIP 9 to ON to enable the electric lock pulse release when opening (provided DIP 8 is ON).
If a command to open the gate is given when the gate is closed, the closing movement is
performed for 0.5 seconds and the electric lock is simultaneously activated (followed by a 0.5
second pause and then the opening of the gate).
ELECTRIC LOCK PULSE ENGAGEMENT
Set DIP 10 to ON to enable the pulse engagement of the electric lock when closing. Upon
closing, motors are activated for 0.5 seconds at full voltage to ensure lock engagement.
EASY MOTOR RELEASE
Set DIP 11 to ON to enable easy manual release (provided that DIP 10 is ON), upon closing a
reverse motion with a fixed time of 0.2 seconds occurs to facilitate manual release.
OPERATION OF SAFETY ACCESSORIES
PHOTOCELL (COM-PHOT)
DIP 4 OFF =>if an obstacle is placed in range of the photocells when the gate is closed,
the gate does not open. During operation, photocells work when opening
(by starting the opening movement only after the obstacle is removed)
and closing (by starting the reverse movement only after the obstacle is
removed).
DIP 4 ON =>if an obstacle is placed in range of the photocells when the gate is closed
and the command to open is given, the gate opens (the photocells do not
work while opening). Photocells work only during closing (with reverse
motion restored after a second, even if they are still engaged).
CONTROL OF IMMEDIATE CLOSING AFTER MOVEMENT IN FRONT OF PHOTOCELLS
DIP 16 ON and DIP 4 OFF =>if photocells are engaged during opening, the gate stops
and the gate only closes one second after the photocells
are disengaged.
DIP 16 ON and DIP 4 ON =>if photocells are engaged during opening, the gate
continues to open. Upon disengagement of the photocells,
the gate stops and reverses closing motion after a one
second pause.
If total opening is reached (end of opening time),
immediate closing is deactivated and automatic
time closing is activated (if TCA trimmer is activated
and LED DL6 is on). If during closing there is a rapid
movement (e.g. pedestrian) the gate will open again
for two seconds and then close once again.
DIP 12 OFF =>immediate closing after movement in front of the photocells
is deactivated.
N.B.: Please check photocell operation at least every six months.
EDGE (SAFETY STRIP) (COM-EDGE)
If engaged during opening, reverses the motion when closing.
If engaged when closing, reverses the motion when opening.
If it remains engaged again, it performs a further reversal after 2 seconds, then performs an
additional short reversal and then gives the sensor failure or engaged alarm (N.O. contact).
If the sensor remains engaged (N.O. contact) no movement is allowed.
If not used, jump the terminals COM-EDGE.
MONITORING OF SAFETY SENSORS (A+ TEST A-)
Sensors can be monitored through the A+ TEST input and DIP 12 ON.
The monitoring consists of a functional test of the sensor run after every full gate opening.
Closing the gate is therefore permitted only if the sensors have passed the functional test
after each opening.
CAUTION: MONITORING OF THE SENSOR INPUT CAN BE ACTIVATED WITH DIP 12 ON OR
DEACTIVATED WITH DIP 12 OFF. IN FACT, THE FUNCTIONAL TESTING OF SENSORS IS
‘POSSIBLE ONLY IF THESE DEVICES HAVE THEIR OWN POWER SUPPLY.
A MECHANICAL SENSOR CAN NOT BE MONITORED, SO DIP 12 SHOULD BE SET TO OFF.
SENSOR AUTOTEST ALARM (DIP 12 ON)
If the sensor fails the monitoring test after opening, an alarm is displayed by the blinker
lighting up. Gate closure is not allowed in this condition. Normal operation can be restored
only by repairing the sensor and pressing one of the activated controls.
STOP BUTTON (COM-STOP)
The STOP button stops the gate during any operation.
If held when the gate is fully open (or partially when using the pedestrian control) automatic
closing is temporarily deactivated (if activated by the TCA trimmer and LED DL6 on). It is
therefore necessary to use a new command to make it close.
The automatic closing function is reactivated on the next cycle (if activated by the TCA
trimmer and LED DL6 on).
POWER SENSOR ALARM
The T2 24V control panel has automatic sensors that make the movement of the gate
reverse in case of impact against objects or persons in accordance with the current EN
standards (always use the right tool to ensure compliance with the values imposed by the
standard), without special adjustments on the control panel, as it operates using special
internal software.
If the power sensor is used in opening or closing (only in high-speed) and then again, in the
opposite direction, the gate stops and then reverses for 1 second.
The alarm status will be displayed by the blinker which will remain active for one minute,
during which time you can restore gate operation by pressing any command button.
FUNCTIONING IN DEAD MAN MODE WHEN THE SAFETY DEVICES ARE FAILING
If the safety edge fails or remains engaged for more than 5 seconds, or if photocell fails
or remain engaded for more than 60 seconds, the open, close, k button and pedestrian
commands will work only in dead man mode.
The signal that this mode has been activated is given by the blinking of the programming led.
With the blinking of the programming led, the opening and closing operation are allowed
only with the command button pressed and held. The radio commands and that of automatic
closing, will be excluded, since their use in this mode, is not allowed by the norms.
Once the failing safety device is repaired, in automatic after 1 second, all standard
commands that were selected, such as step by step, automatic mode, radio commands and
automatic closing start functioning again.
Note 1: during this functioning in dead man mode, in case of damage to the safety strips
(or photocells) the photocells (or safety strips) still work by interrupting the operation
in progress.
Note 2: the stop command is not to be considered a safety command that can be bypassed
in this mode. Therefore, when pressed or damaged, it will not allow any movement
of the gate.
The dead-man operation is only an emergency operation which must be activated
for a very short period and with the complete installation at sight so to have a
secure and safe control of the system. As soon as possible however, the failing
safety devices must be repaired and activated.
BLINKER
N.B.: This control panel can power ONLY BLINKERS ON A (ACG7061) CIRCUIT with lamps
35
35
G
B
TECHNICAL SPECIFICATIONS
up to 24V and 20W.
- Temperature range
0 ÷ 55°C
- Humidity<95% without condensation
- Voltage
230V~ ± 10%
(120V/60Hz upon request)
- Frequency
50/60 Hz
- Battery power
20-24Vdc
- Transformer Power130VA primary 230Vac
secondary 18Vac
- Maximum absorption
50 mA
- Network Micro-switches
100ms
- Maximum power gate open indicator24Vdc 3W (equivalent to one 3W
or 5 LED light bulb with resistor in
series at 2.2 K ohm)
- Maximum blinker power
24Vdc 20W
- Power available for photocells and accessories
1A ± 15%
- Power available for radio connector
200Ma
PRE-BLINKING
DIP 5 - OFF => the motor and blinker begin simultaneously.
DIP 5 - ON => the blinker begins 3 seconds before the motor.
GATE OPEN WARNING LIGHT (COM-SIGNAL)
Signals when the gate is open, partially open or not closed completely. Turns off only
when the gate is completely closed.
This signal is active during programming.
N.B.: Max 3 W. If push buttons or lamps are in excess, the control panel processes will
be endangered and possibly halt operation.
OPERATION AFTER A BLACK-OUT (WITHOUT BATTERIES)
When the power supply comes back the DL1 led turns on and remains on for all the time
the gate stays open. The led will turn off only once the gate is completely closed.
It is recommended to fully open the gate. Let the gate close by itself or with automatic
closing, or wait until the blinker stops flashing before commanding it to close.
This will allow the gate to realign. If, motors were released and moved from the normal
position when closed during the blackout, the first movement after power returns must
be complete.
If the black out occurs when the gate is still moving or when the gate is open and the
first command sent after the black out is a closing command, the closing of the gate will
be carried out with a total delay between the two gate leaves. Therefore, first the leaf M2
will close completely; once it is off, M1 will start closing. This separate movement of the
two gate leaves is done to avoid their incorrect overlapping.
RADIO SPECIFICATIONS (model T2 24V CRX)
- Receiving Frequency
- Impedance
- Sensitivity
- Pick-up time
- Drop time
433,92 MHz
52 OHM
>2,24µV
300ms
300ms
- All inputs must be used as clean contacts because the power is generated internally
(secure power) to the board and is set up to ensure compliance with double or
reinforced insulation with regard to dangerous voltage.
- Any external circuits connected to the outputs of the control panel must be made in
such a manner as to ensure compliance with double or reinforced insulation with regard
to dangerous voltage.
- All inputs are controlled by a programmed integrated circuit that performs a self check
every time it starts operating.
TROUBLE SHOOTING
After having carried out all connections, by carefully following the layout and having positioned the gate in intermediate position, check the correct ignition of red LEDS DL7, DL8 and DL9
In case of no ignition of the LEDS, always with gate in intermediate position, check the following and replace any faulty components.
DL7
switched off
Faulty photocells
DL8
switched offFaulty safety edge (In case the edge is not connected, carry out jumper between COM and EDGE)
DL9
switched offStop button malfunction (if Stop is not connected, perform the jump between COM and STOP).
During functioning with personnel present, with DIP 1 at ON, check that during opening of M1 and M2 the green DL2 and DL4 LEDS switch on and that during closing of M1 and M2 the
red DL3 and DL5 LEDS switch on.
Or else, reverse the wires of the motor.
FAULT
SOLUTION
Check fuses F1, FUSE 1.
After having carried out the various connections and having supplied voltage, all the LEDS If the fuse is blown, use only a suitable replacement.
F1 T 2ATRANSFORMER PROTECTION FUSE (on the outside of the T2 24V board)
are switched off.
FUSE 1 8A MOTOR PROTECTION FUSE
The motor opens and closes, but it has no strength and moves slowly.
Check trimmers RUN and LOW-SPEED adjustment.
The gate opens but does not close after the time set.
Make sure that the TCA trimmer is activated with LED DL6 on.
OPEN button always on, replace the OPEN control button or switch.
Sensor Auto test failed, check the connections between the control panel and the sensor
power supply.
Warning: If you are not using a power supply for the sensors, DIP 12 should be OFF.
The gate does not open or close by activating the various K, Radio, Open and Close buttons.
Faulty safety edge contact. Faulty photocells contact with DIP 4 OFF.
Fix or replace the relative contact.
The electric lock does not work.
Ensure to have enabled DIP 8 at ON.
LED DL1 blinks rapidly and no movement is activated.
Place dip switches 1, 2 or 3 in the OFF position.
36
G
B
ACCESSORIES
For the connections and the technical data of the optional equipments follow the relevant handbooks.
RADIO TRANSMITTER SUN
SUN 2CH
SUN CLONE 2CH
code ACG6052
code ACG6056
SUN 4CH
SUN CLONE 4CH
code ACG6054
code ACG6058
BATTERY CHARGE CARD
BATTERIA
code ACG4648
Battery 2,2Ah 12V
code ACG9515
Wi-Fi DEVICES
MASTER Wi-Fi
RECEIVER CARD TO MANAGE WIRELESS SYSTEM
with connector - 12÷30V ac/dc
with terminal block - 12÷30V ac/dc
code ACG6094
code ACG6099
VERTIGO Wi-Fi
NOVA Wi-Fi
PHOTOCELLS WITHOUT WIRES
PAIR OF COLUMS NOVA
code ACG8037
code ACG8039
SPARK Wi-Fi
BLOCK Wi-Fi
KEY SELECTOR WITHOUT WIRES
WIRELESS PHOTOCELLS SUBSTITUTING THE SAFETY STRIP
VERTIGO Wi-Fi 8 code ACG8042 - VERTIGO Wi-Fi 10 code ACG8043
code ACG6098
BLINKER WITHOUT WIRES
LATERAL SUPPORT
code ACG7064
code ACG7042
D
ANLAGEN LAY-OUT
❸
❷
TECHNISCHE EIGENSCHAFTEN
KING 24V ist ein irreversibler System von selbsthemmenden Antrieben mit
elektrischer Rutschkupplung die für Drehtore mit den Torflügen bis zu 4 m
verwendbar sind (Fig. 1).
❹
TECHNISCHE
EIGENSCHAFTEN
❺
❶
❶
❺ ❹
KING 24V
Max. Torflügelweite
m
4
Max. Torgewicht
kg
400
Max. Hub
mm
Öffnungszeit ca.
s.
14÷27
Laufgeschwindigkeit
m/s.
0,0125
Max. Schubkraft
N
1800
Stromspannung und Frequenz
24V
24V
Motorleistung
W
118
Stromaufnahme
A
5,4
Max. tägliche Zyklen
n°
Service
1 - Operatore KING 24V
2 - Antenna radio
3 - Lampeggiatore
4 - Selettore a chiave
5 - Fotocellule esterne
150
90%
Garantierte kontinuierliche Zyklen
1
345*
n°
Schmiere
200/14s
Bechem - RHUS 550
Motorgewicht
kg
10
Geräusch
db
<70
Volumen
m3
0,0184
Betriebstemperatur
°C
-10 ÷ +55°C
Schutzartklasse
IP
44
* Mit eingebautem mechanischen Anschlag, der während der Öffnung anspricht. Wird auch der
optionale mechanische Anschlag benutzt, der während des Schließens anspricht, so reduziert sich
der maximale Zughub um 50 mm.
SCHWARZ 1
Verbinden Sie J5 oder J6
Klemme +
SCHWARZ 2
Verbinden Sie J5 oder J6
Klemme -
Abmessungen in mm
2
38
D
INSTALLATION
PRÜFUNG VON DER MONTAGE
Das Flugeltor muß fest an der Angelpunkten der Träger fixiert sein, darf sich während der
Bewegung nicht biegen und ohne Reibung bewegen.
Bevor KING 24V montiert wird ist es besser alle Hindernisse, die bei der Montage
auftreten können festzustellen.
Bei einem Tor wie in Abbildung 1 müssen keine Veränderungen vorgenommen werden.
Es ist erforderlich, die Charakteristiken des Tors an die geltenden Normen und
Gesetze anzupassen. Das Tor kann nur automatisch Angeschlossen werden, wenn es
in einem einwandfreien Zustand ist und der EN12604 entspricht.
- Das Tor welches keine Gehfluegelfunktion hat,in diesem Fall ist es erforderlich das Tor
mit der norm EN12453 in Einklang zu bringen(z.B. das in Bewegung setzen des Motors
per Handsender, wenn der Gehfluegel geoeffnet ist. Das zu vehindern koennen sie
einen Endschalter anschliessen der beim oeffnen des Gehfluegel andere automatischen
funktionen ausser Kraft setzt).
- Es dürfen keine mechanischen Anschläge über dem Tor vorhanden sein, da diese nicht
ausreichend sicher sind.
3
Komponenten zur Installation nach der Norm EN1253
ANWENDUNG DER SCHLIESSUNG
STEUERUNGSSYSTEM
Fachpersonen
(außer einem
öffentlichen Platz*)
Fachpersonen
(öffentlicher Platz)
Grenzlose
Anwendung
mit Totmannschaltung
A
B
nicht möglich
mit sichtbaren
(z.B. Sensor)
C oder E
C oder E
C und D, oder E
mit nicht sichtbaren
Impulsen (Fernsender)
C oder E
C und D,
oder E
C und D, oder E
automatisch
C und D,
oder E
C und D,
oder E
C und D, oder E
4
* e in Musterbeispiel dafür sind jene Türe, die keine Zufahrt zu einem öffentlichen
Weg haben
A: Betriebstaste mit Totmannschaltung (das heißt, aktivieren sie eine Funktion,
solange man sie gedrückt hält), wie Kode ACG2013
B: Schlüsselselektor mit Totmannschaltung, wie Kode ACG1010
C: Justierbare Kraft des Motors
D: Kontaktleiste und /oder andere Sicherheitseinrichtungen muessen mit den Norm
EN12453 uebereinstimmen (Anhang A).
E: Photozelle, wie Kode ACG8026 (Jede 60÷70 cm für die ganze Höhe der Spalte des
Gatters bis zu einem Maximum von 2,5 m anwenden - EN 12445 Punkt 7.3.2.1)
5
sorgfältig
einfetten
NOTENTRIEGELUNG
6
Um das Tor des Modells KING 24V manuell zu bedienen, müßen Sie den dafür
vorgesehenen Schlußel in das Schloß stecken und ihn 2 mal entgegen dem Uhrzeigersinn
drehen (Abb. 3).
Um das Tor manuell richtig zu pruefen muessen folgende Punkte beachtet werden:
- Das Tor muss einen geeigneten Griff haben.
- Dieser Griff muss so angebracht sein das er kein Risiko ist beim Test.
- Daß die physische notwendige Kraft um das Tor-Blatt zu bewegen nicht höher als
225N ist, für Tore bei privaten Wohnungen, und 390N für Tore für kommerzielle und
industrielle Situationen (Werte nach 5.3.5 vom EN 12453 Norm).
JA !
Achten
Sie
darauf,
die Schraube, die die
Halterung hält an den
Betreiber, so dass es sich
frei drehen kann anziehen.
BEFESTIGUNG DES ANTRIEBES AUF DIE SÄULE
Um KING 24V zu montieren, müssen einige Maße beachtet werden, damit eine richtige
Bewegung des Torflügels gegeben ist.
Falls der Torträger aus Eisen ist, kann man die Verankerung direkt anschweißen.
Bei einem Torträger aus Zement bedient man sich einer Platte wie in Abb. 4, die man mit
4 Fischer-Dübel Ø 8 mm anschraubt.
Nacher wird auf den Torflügel der Anschluß für die Förderschnecke geschweißt.
Die vorgesehenen Maße sind naturlich zu beachten.
Im Falle, es existiert eine Maurer, die parallel zum Tor im offenen Zustand läuft, ist es
notwendig eine Wandvertiefung zu schaffen, um Platz für den Motorantrieb zu haben.
NEIN !
BEFESTIGUNG DES ANTRIEBES AUF DAS TORFÜGEL
Der Betreiber muss
seine Höhe während der
Bewegung nicht ändern.
Schmieren sorgfältig, bevor die Zapfen in dem Sockel stecken.
Schweißen Sie den Sockel in der richtigen Höhe (Fig. 6, 7) an.
Befestigen Sie KING 24V und versuchen Sie mehrere Male zu öffnen und zu schließen,
Kontrollieren Sie dabei, daß das Profil der Schraubenabdeckung das Tor in Bewegung
nicht berührt.
39
D
COL
Halterung Pfeiler
Z
Y
X
S1
45
X
Y
Z
S2
Beachten Sie die Maßnahme
und stellen Sie sicher, dass
der Betreiber ist horizontal
ANT
Halterung Torfluegel
Z
A
Y
B
X
S3
7
DIE KORREKTEN ABMESSUNGEN UND INSTALLATION MIT EINEM STOPPER IM ANTRIEB
L
Min.÷Max
a
A
max
B
C
D
E
T
sec
ANT
COL
1÷1,80
45
100
100
815
90
14
A
S3-Y
1,81÷2,20
45
110
110
815
90
18
A
S3-X
70
140
110
815
90
20
A
S1-Z
2,51*÷3,00*
90
170
140
815
115
25
B
S2-Y
3,01*÷3,50*
115
200
140
815
115
27
B
S2-Y
B
C
D
E
ANT
COL
90
140
815
90
20
A
S1-Z
100
130
815
90
21
A
S2-Y
110
140
815
115
24
B
S1-Y
2,21÷2,50
L
Min.÷Max
90°
a
A
max
1÷1,80
1,81÷2,20
2,21÷2,50*
110°
20
* Ab Flügelmaß von 2,5 Metern muß ein elektrisches
Schloß zur Gewährleistung einer wirkungsvollen
Schließung angebracht werden.
Falls der Torantrieb nicht mit dem richtigen Maß (B) montiert
werden kann, da der Torträger zu breit ist, muß man in der
Säule eine Wandvertiefung schaffen oder das Tor an den Rand
versetzen.
T
sec
ANT
Halterung Torfluegel
A
B
COL
Halterung Pfeiler
Z
Y
X
S1
FÜR EINE KORREKTE INSTALLATION MIT ZWEI MECHANISCHE SPERRVORRICHTUNG
L
Min.÷Max
a
1÷1,80
1,81÷2,20
2,21÷2,50
90°
2,51*÷3,00*
L
Min.÷Max
a
A
C
D
E
45
100
100
775
90
14
45
110
110
775
90
70
140
110
775
115
70
160
140
775
115
B
C
D
E
A
max
1÷1,80
1,81÷2,20
2,21÷2,50*
40
110°
T
B
max
20
ANT
COL
A
S3-Y
18
A
S3-X
20
B
S1-Z
25
B
S1-Y
ANT
COL
sec
T
sec
90
140
775
90
20
A
S1-Z
100
130
775
90
21
A
S2-Y
110
140
775
115
24
B
S1-Y
D
MECHANISCHE SPERRVORRICHTUNG - OPTIONEN
Code ACG8089
Als Zubehör eine mechanische Sperrvorrichtung, die das Gittertor beim Schließen anhält,
falls keine Feststellvorrichtung auf dem Boden vorhanden ist (Abb. 8).
8
EINSTELLUNG DES MECHANISCHEN ENDSCHALTERS
Um die Endschalter einzustellen, müssen Sie wie in der Abbildung handeln (Abb. 9).
Um die erwünschte Offnungsweite einzustellen, genüngt es, die Endschalter (A) zu
verstellen und sie mit Hilfe eines Imbusschlüßels an der Mutterschraube festzuziehen.
Um die erwünschte Schliessweite einzustellen, müssen Sie die Endschalter (B) verstellen.
9
WARTUNG
Die Wartungsarbeit nur durch spezialiesierten Fachleuten nach der Ausschliessung der
Spannung auszuführen.
Einmal jährlich sind die Angelzapfen zu schmieren und die vom Getriebemotor ausgeübte
Antriebskraft.
Es wird empfohlen, alle zwei Jahre die Schnecke mit Silikonfett zu schmieren.
10
41
D
T2 24V
T2 24V CRX
ELEKTROANSCHLÜSSE
Kode AC07088
Kode AC07089
24Vdc 0,8A ± 15% für ZUBEHÖRE
24Vdc 0,8A ± 15% für AUTOTEST KONTAKTLEISTE
FUSSGÄNGER
EINZELIMPULS
ELEKTROSCHLOSS
FOTOZELLEN
GEMEINSAME ERDUNGSKONTAKTE
KONTAKLEISTE
LED
BLINKER
24Vdc 20W
STROMVERSORGUNG
230Vac 50 Hz
SICHERUNG
T2A
TRANSFORMATOR
R=2,2K 1/4W
GEMEINSAME
ERDUNGSKONTAKTE
SCHLIEßEN
ÖFFNEN
STOPPSCHALTER
ANTENNE
Zopfflechten
ANTENNE
M1
M2
42
D
J1
NF
Speisung 230 Vac 50/60 Hz - extern an der Karte (120V/60Hz auf Anfrage)
J2
COM.
Gemeinsame erdungskontakte
CLOSE
Schließung-Impuls-Kontakt (NA)
OPEN
Öffnungs-Impuls-Kontakt (NA)
STOP
Stop-Impuls-Kontakt (NC)
AERIAL
Radio Antenne
SIGNAL
Kontrollanzeigelampe Tor offen, signalisiert den Batterie
betriebenen Funktionierungsstand und leere Batterie (24Vdc
3W max)
J3
A - VERBINDUNGEN
J1
J2
A+TEST
Positive Ladung für die Speisung für Rippen Selbstkontrolle
EDGE N.C.
Ripppen-Kontakt (NC)
COM.
Gemeinsame Erdungskontakte
PHOTO N.C.
Fotozellen-Kontakt (NC)
K BUTT.
Einzel-Impuls-Kontakt (NA)
PED. BUTT.
Kontakt Befehl Öffnung für den Fußgängerdurchgang (NA)
A+
Positive Ladung für die Speisung für Rippen Selbstkontrolle
A-
Negative Ladung für die Speisung der Zubehöre zu 24Vdc
LOCK
Anschluss zu Elektroschloss-Riegelung (MAX 15W 12V)
F1
J3
TRANSFORMER
J4
FUSE 1
J9
J10
J5
Anschluss zu Blinker Negativ-Fase zu 24Vdc (Kode
ACG7061) auf die Polarität achten.
J4
SECONDARY
TRANSFORMER
Verbinder für Sekundär Transformator 18 Vac
J5
MOTOR 1
Verbindung MOTOR 1 (ohne Polarität)
J6
MOTOR 2
Verbindung MOTOR 2 (ohne Polarität)
SW T2 24V
Verbinder für die Programmierung in der Fabrik. NICHT
DIE ÜBERBRÜCKUNG BERÜHREN ! OHNE ANTRIEB NICHT
BETRIEBSFÄHIG!
SW RADIO
Verbinder für die Programmierung in der Fabrik (nur für die
Modelle CRX). NICHT DIE ÜBERBRÜCKUNG BERÜHREN !
OHNE ANTRIEB NICHT BETRIEBSFÄHIG!
J7
J8
J9
RADIO
Radio-Modul eingebaut (Modell CRX), oder Verbinder für
Radioempfänger RIB Steckverbindung mit Speisung zu
24Vdc
J10
BATTERY
CHARGER
Verbinder für Batterie-Aufladekarte zu 24Vdc (Kode
ACG4648)
TR1
TRIMMER RUN
Trimmer elektronischer Regler für hohe Geschwindigkeit
TR2
TRIMMER LOW
SPEED
Trimmer langsamlaufregler nur bei Schließung
TR3
TRIMMER TCA
Trimmer automatische schliessung vollständig oder
Teilweise - Standardeinstellung: NICHT ZUGELASSEN und
LED DL6 AUSGESCHALTET
B - EINSTELLUNGEN
DIP 1
DIP 2
DIP 3
DIP 1-2
DIP 1-3
DIP 2-1
DIP 4
DIP 5
DIP 6
DIP 7
DIP 8
DIP 9
DIP 10
DIP 11
DIP 12
J6
J8
J7
TR3
S3
TR1
( ON) - STEUERUNG MOTORDREHRICHTUNG (PUNKT C)
(ON) - ZEITPROGRAMMIERUNG (PUNKT D)
(ON) - FLÜGELFREIGABE WÄHREND DER LAUFVERLANG-SAMUNG, UND
AUCH BEI VOLLSTÄNDIGER ÖFFNUNG UND SCHLIESSUNG (IM HINBLICK AUF
DIE ANSCHLAGPROBEN LAUT EN12453)
SPEICHERUNG/LÖSCHEN DER FUNKCODES FÜR BEFEHL VOLLSTÄNDIGES
SCHLIESSEN (NUR MODELL CRX) (PUNKT E)
SPEICHERUNG/LÖSCHEN DER FUNKCODES FÜR BEFEHL FUSSGÄNGERÖFFNUNG (NUR MODELL CRX) (PUNKT F)
ZEITPROGRAMMIERUNG FUSSGÄNGER - ÖFFNUNG BETRIEBSMIKROSCHALTER
Fotozellen immer aktiv (OFF) - Fotozellen nur bei Schließung aktiv (ON)
Vorblinken (ON) - Normales Blinken (OFF)
Befehl Einzelimpuls (K BUTT) und eingebautes Radiogerät Schritteinzelbefehl (OFF)
- automatisch (ON)
Funktionsweise mit Stromsensoren (ON-aktiviert) Funktion auf Zeit (OFF-aktiviert).
Freigabe elektrische Verriegelung (ON-aktiviert)
Freigabe Rückschlag elektrische Verriegelung (ON-aktiviert)
Freigabe Rückschlag elektrische Verriegelung (ON-aktiviert)
Freigabe Erleichterte Entblockung (ON-aktiviert)
Freigabe TEST Selbstkontrolle der Kontaktleiste (ON-aktiviert).
S3
PROG
Programmierungs-Schaltknopftaste
FUSE 1
T8A
Sicherung Motorschutz
F1
T2A
Sicherung Transformatorschutz
TR2
DIP 13 Wahlweiser Betrieb mit 1 oder 2 Motoren (Standardeinstellung: OFF 2 Motoren)
DIP 14 KING 24V - ON
DIP 15 KING 24V - ON
DIP 16 SOFORT-SCHLIESSUNG NACH DEM PASSIEREN DER FOTOZELLEN
EINAKTIVIERT
AUSDESAKTIVIERT
JP1 => Überbrückung muss angewählt sein!
JP2 => Überbrückung muss angewählt sein!
JP3 => Überbrückung muss angewählt sein!
PROG => S3 Programmierschalter
EINSTELLUNGEN
ACHTUNG: AKTIVIEREN DAS DIP 3 NÜR NACH ALLE DIE PROGRAMMIERUNGEN.
ZU BEACHTEN: MIT DIP 3 (ON) WIRD DIE FUNKTION DER KURZFRISTIGEN
FLÜGELUMKEHR NACH DEM ANSCHLAG AKTIVIERT.
DIESE KURZFRISTIGE FLÜGELUMKEHR REDUZIERT DIE STATISCHE KRAFT
INNERHALB VON 5 SEKUNDEN AUF NULL LAUT PUNKT A.2.2 DER NORM EN12453
(BETRIEBSKRÄFTE) UND ERLAUBT SOMIT DIE EINHALTUNG DER ANSCHLAGPROBEN
LAUT DERSELBEN NORM EN12453.
SOLLTE KEINE NOTWENDIGKEIT BESTEHEN, DER OBEN BESCHRIEBENEN NORM
NACHZUKOMMEN, REICHT ES AUS, DIP 3 AUF AUS ZU STELLEN. IN DIESEM FALL
SCHLIESSEN SICH DIE FLÜGEL, OHNE DIE BEWEGUNG ZU INVERTIEREN.
43
D
TRIMMER RUN (TR1) Elektronischer Regler für hohe Geschwindigkeit
Mit diesem Trimmer kann die Motorgeschwindigkeit eingestellt werden (Standardeinstellung:
Höchstgeschwindigkeit). Diese Regulierbarkeit ist von Nutzen, um die Automatik mit den
Europäischen Normen im Bezug auf den Anschlag konform zu gestalten.
TRIMMER LOW SPEED (TR2) Langsamlaufregler nur bei Schließung
Die Einstellung des Langsamlaufes erfolgt über den Trimmer LOW SPEED durch
Spannungsregulierung der Motoren (im Uhrzeigersinn drehend wird die Geschwindigkeit
erhöht). Diese Einstellung reguliert die korrekte Geschwindigkeit am Ende der Öffnung und
der Schließung je nach Torstruktur oder beim Auftreten von leichter Reibung, die die korrekte
Funktionsweise des Systems beeinträchtigen könnten.
TRIMMER AUTOMATISCHE SCHLIESSUNG TCA (TR3) VOLLSTÄNDIG ODER TEILWEISE
(FUSSGÄNGER-ÖFFNUNG) Standardeinstellung: NICHT ZUGELASSEN und LED DL6
AUSGESCHALTET (TRIMMER VOLLSTÄNDIG IM UHRZEIGERSINN GEDREHT)
Dieser Trimmer erlaubt die Zeiteinstellung vor der automatischen Schließung sowohl teilweise
als auch vollständig. Funktioniert nur bei kompletter vollständigere oder teilweiser (FußgängerÖffnung) Öffnung und eingeschalteter LED-Anzeige DL6 (Trimmer im Uhrzeigersinn gedreht).
Die Pause kann von mindestens 2 Sekunden bis maximal 2 Minuten eingestellt werden.
LED-ANZEIGEN
DL1 Programmierung aktiviert (Rot)
DL2 Tor in Öffnung M2 (Grün)
DL3 Tor in Schließung M2 (Rot)
DL4 Tor in Öffnung M1 (Grün)
DL5 Tor in Schließung M1 (Rot)
DL6 Zeitangabe automatische Schließung (Rot)
DL7 Kontakt Fotozellen (NC) (Rot)
DL8 Kontakt Kontaktleiste (NC) (Rot)
DL9 Befehl STOPP (NC) (Rot)
DL10 Programmierung Funkcodes (Grün)
SICHERUNGEN
Fuse 1 T 8A SICHERUNG MOTORSCHUTZ
F1 T 2ASICHERUNG TRANSFORMATORSCHUTZ (außerhalb des Steckverbinders T2
24V)
C - STEUERUNG MOTORDREHRICHTUNG
1 - DIP 1 auf ON stellen=> Die LED-AnzeigeDL1 beginnt zu blinken.
2 - Den Schalter PROG. drücken und gedrückt halten (die Bewegungen Öffnen-StoppSchließen-Stopp-Öffnen-usw. werden vom Steuerpult aus bedient) => DIE GRÜNEN
LED-ANZEIGEN DL2 und DL4 leuchten auf und die Flügel öffnen sich mit fixer
Phasenverschiebung von 2 Sekunden. Schließen sie sich hingegen statt sich zu öffnen,
den Schalter loslassen und die beiden Anschlüsse des betreffenden Motors invertieren.
3 - Nach der vollständigen Öffnung den Schalter PROG. loslassen und das Tarieren der
Öffnungs-Endanschläge vornehmen (am Bedienelement).
4 - Den Schalter PROG. drücken und gedrückt halten => DIE ROTEN LED-ANZEIGEROSSI
DL3 und DL5 leuchten auf und die Flügel schließen sich mit fixer Phasenverschiebung
von 2 Sekunden
5 - Den Schalter PROG bis zur vollständigen Schließung des Tors gedrückt halten.
6 - Zur Zeitprogrammierung beide Flügel vollständig geschlossen halten.
7 - DIP1 wieder auf OFF stellen => Die LED-AnzeigeDL1 erlischt und zeigt das Ende der
Kontrolle an.
ZU BEACHTEN. Während dieser Kontrolle sind der Stopp, die Fotozellen und die
Kontaktleisten nicht aktiv.
D - ZEITPROGRAMMIERUNG BEI 2 MOTOREN (#) MIT AKTIVIERTEM
STROMSENSOR (DIP 7 ON)
WÄHREND DER PROGRAMMIERUNG BLEIBT DER STROMSENSOR IMMER AKTIV:
1 - Das Tor muss vollständig geschlossen sein.
2 - DIP 2 auf ON stellen=> Die LED-AnzeigeDL1 beginnt zu blinken.
3 - Den Schalter PROG. drücken=> M1 öffnet.
4 - Nach Erreichen des Öffnungs-Endanschlages, hält der AUTOMATISCHE STROMSENSOR
M1 an (und speichert Zeit und Stromwerte) => Gleichzeitig aktiviert sich M2 und öffnet.
5 - Nach Erreichen des Öffnungs-Endanschlages, hält der AUTOMATISCHE STROMSENSOR
M2 an (und speichert Zeit und Stromwerte)
6 - Den Schalter PROG. drücken=> M2 schließt.
7 - Den Schalter PROG. drücken => M1 schließt und bestimmt die Phasenverschiebung
zwischen M2 und M1. Gleichzeitig erlischt die LED-Anzeige DL1 und zeigt das Ende der
Speicherprozedur an.
Ab diesem Zeitpunkt funktionieren die Sicherheitsbefehle des Tor normal (Umkehr,
Stopp, Alarmfunktionen, usw....).
8 - Die Schließung der Flügel erfolgt mit hoher Geschwindigkeit (je nach Einstellung des
Trimmers RUN) und mit Laufverlangsamung gegen Ende der vollständigen Schließung (je
nach Einstellung des Trimmers LOW SPEED).
9 - Bei Erreichen der vollständigen Schließung halten die Sensoren das Tor an.
10 - NACH BEENDIGUNG DER PROGRAMMIERUNG DIP 2 AUF OFF STELLEN.
D - ZEITPROGRAMMIERUNG BEI 1 MOTOR (M1) (#) MIT AKTIVIERTEM
STROMSENSOR (DIP 7 ON)
ACHTUNG: BEI NUR EINEM MOTOR MUSS DIP 13 AUF GESTELLT WERDEN ON
WÄHREND DER PROGRAMMIERUNG BLEIBT DER STROMSENSOR IMMER AKTIV.
Das Tor muss vollständig geschlossen sein.
1 - DIP 2 auf EIN stellen=> Die LED-AnzeigeDL1 beginnt zu blinken.
2 - Den Schalter PROG. drücken=> M1 öffnet.
Nach Erreichen des Öffnungs-Endanschlages, hält der AUTOMATISCHE STROMSENSOR
M1 an (und speichert Zeit und Stromwerte).
3 - Den Schalter PROG. drücken => M1 schließt.
Gleichzeitig erlischt die LED-AnzeigeDL1 und zeigt das Ende der Speicherprozedur an.
Ab diesem Zeitpunkt funktionieren die Sicherheitsbefehle des Tor normal (Umkehr,
Stopp, Alarmfunktionen, usw....).
Bei Erreichen der vollständigen Schließung halten die Sensoren das Tor an.
4 - NACH BEENDIGUNG DER PROGRAMMIERUNG DIP 2 AUF OFF STELLEN.
(#) WÄHREND DER PROGRAMMIERUNG BLEIBEN DIE SICHERHEITSBEFEHLE AKTIV
UND IHR EINGREIFEN FÜHRT ZUM ANHALTEN DER PROGRAMMIERUNG (DIE LEDANZEIGEDL1 BLINKT NICHT MEHR, SONDERN BLEIBT ERLEUCHTET). UM MIT DER
PROGRAMMIERUNG FORTZUFAHREN, DIP 2 AUF AUS STELLEN, DAS TOR ÜBER
DEN VORGANG “STEUERUNG MOTORDREHRICHTUNG” SCHLIESSEN UND DIE
PROGRAMMIERUNG WIEDERHOLEN.
D - ZEITPROGRAMMIERUNG BEI 2 MOTOREN (#) AUF ZEIT (DIP 7
OFF)
1 - Das Tor muss vollständig geschlossen sein.
2 - DIP 2 auf ON stellen=> Die LED-AnzeigeDL1 beginnt zu blinken.
3 - Den Schalter PROG. drücken=> M1 öffnet.
4 - 1 Sekunde nach Erreichen des Öffnungs-Endanschlages, den Schalter PROG. drücken=>
M1 schließt und M2 öffnet.
5 - 1 Sekunde nach Erreichen des Öffnungs-Endanschlages, den Schalter PROG. drücken
=> M2 schließt.
6 - Den Schalter PROG. drücken. => M2 schließt.
7 - Den Schalter PROG. drücken => M1 schließt und bestimmt die Phasenverschiebung
zwischen M2 und M1
Gleichzeitig erlischt die LED-AnzeigeDL1 und zeigt das Ende der Speicherprozedur an.
Ab diesem Zeitpunkt funktionieren die Sicherheitsbefehle des Tor normal (Umkehr,
Stopp, Alarmfunktionen, usw...).
8 - Nach der Zeitbestimmung schließt das Tor
9 - NACH BEENDIGUNG DER PROGRAMMIERUNG DIP 2 AUF OFF STELLEN.
ANMERKUNG: Die Laufverlangsamung wird automatisch durch die Steuerung während
der Zeitprogrammierung bestimmt und wird etwa 50÷60 cm vor dem Öffnungs- oder
Schließungs-Endanschlag aktiviert.
D - ZEITPROGRAMMIERUNG BEI 1 MOTOR (#) AUF ZEIT (DIP 7 OFF)
ACHTUNG: BEI NUR EINEM MOTOR MUSS DIP 13 AUF GESTELLT WERDEN EIN
1 - Das Tor muss vollständig geschlossen sein.
2 - DIP 2 auf ON stellen=> Die LED-AnzeigeDL1 beginnt zu blinken.
3 - Den Schalter PROG. drücken => M1 öffnet.
4 - 1 Sekunde nach Erreichen des Öffnungs-Endanschlages, den Schalter PROG. drücken=>
M1 schließt.
5 - Den Schalter PROG. drücken => M1 schließt.
Gleichzeitig erlischt die LED-AnzeigeDL1 und zeigt das Ende der Speicherprozedur an.
Ab diesem Zeitpunkt funktionieren die Sicherheitsbefehle des Tor normal (Umkehr,
Stopp, Alarmfunktionen, usw....).
6 - Nach der Zeitbestimmung schließt das Tor.
7 - NACH BEENDIGUNG DER PROGRAMMIERUNG DIP 2 AUF OFF STELLEN.
D-P
ROGRAMMIERUNG
ÖFFNUNGSZEITEN
FUSSGÄNGERÖFFNUNG (#) SOWOHL AUF ZEIT ALS AUCH MIT AKTIVIERTEM
44
D
STROMSENSOR
Bei geschlossenem Tor:
1 - DIP2 auf ON schalten (Die LED-AnzeigeDL1 blinkt rasch) und dann DIP1 auf ON stellen
(Die LED-AnzeigeDL1 blinkt langsam).
2-D
en Fußgängerschalter drücken (COM-PED.BUTT) => M1 öffnet.
3 - Den Fußgängerschalter drücken um das Tor anzuhalten (auf diese Weise wird die Öffnung
von M1 bestimmt).
4-D
en Fußgängerschalter drücken um das Tor zu schließen.
5 - Ist das Tor geschlossen DIP1 und 2 auf OFF stellen.
(#) W
ÄHREND DER PROGRAMMIERUNG BLEIBEN DIE SICHERHEITSBEFEHLE AKTIV
UND IHR EINGREIFEN FÜHRT ZUM ANHALTEN DER PROGRAMMIERUNG (DIE LEDANZEIGEDL1 BLINKT NICHT MEHR, SONDERN BLEIBT ERLEUCHTET). UM MIT DER
PROGRAMMIERUNG FORTZUFAHREN, DIP 2 AUF OFF STELLEN, DAS TOR ÜBER
DEN VORGANG “STEUERUNG MOTORDREHRICHTUNG” SCHLIESSEN UND DIE
PROGRAMMIERUNG WIEDERHOLEN.
E-
PROGRAMMIERUNG FUNKCODES VOLLSTÄNDIGE ÖFFNUNG
(MAX. 62 CODES - NUR MODELLE CRX)
Die Programmierung erfolgt nur bei geschlossenem Tor.
1 - DIP 1 auf ON und anschließend DIP 2 auf ON stellen.
2 - Die rote LED-AnzeigeDL1 für die Programmierung blinkt mit einer Frequenz von 1 Sek.
ON und 1 Sek. OFF für 10 Sekunden.
3 - Die Fernsteuerungs-Taste (normalerweise Kanal A) innerhalb der vorgeschirebenen Zeit
von 10 Sekunden drücken. Wenn die Fernsteuerung korrekt programmiert worden ist,
blinkt die LED-Anzeige DL10 (Grün).
4-
Die Programmierzeit der Codes verlängert sich automatisch, damit die nächste
Fernbedienung programmiert werden kann. .
5 - Um die Programmierung abzuschließen, 10 Sekunden warten oder die Taste PROG
drücken. Die rote LED-Anzeige erlischt.
6 - Erneut DIP 1 und DIP 2 auf OFF stellen.
7 - Ende des Programmiervorgangs.
VORGEHEN ZUR VOLLSTÄNDIGEN LÖSCHUNG DER FUNKCODES FÜR VOLLSTÄNDIGE
ÖFFNUNG
Die Löschung kann nur bei geschlossenem Tor erfolgen.
1 - DIP 1 auf ON und anschließend DIP 2 auf ON stellen.
2 - Die rote LED-Anzeige DL1 für die Programmierung blinkt mit einer Frequenz von 1 Sek.
ON und 1 Sek. OFF 10 Sekunden lang.
3 - Die Taste PROG 5 Sekunden lang gedrückt halten. Die Löschung des Speichers wird
durch zweimaliges Blinken der grünen LED-Anzeige DL10 angezeigt.
4 - Die rote LED-Anzeige DL1 bleibt für die Programmierung aktiv und es ist jetzt möglich,
neue Codes wie oben beschrieben einzugeben.
5 - Erneut DIP 1 und DIP 2 auf OFF stellen.
6 - Ende des Programmiervorgangs.
ANZEIGE “SPEICHERKAPAZITÄT ERSCHÖPFT” FÜR DIE VOLLSTÄNDIGE ÖFFNUNG
Diese Anzeige erhält man nur bei geschlossenem Tor.
1 - DIP 1 auf EIN und anschließend DIP 2 auf EIN stellen.
2-
Die grüne LED-Anzeige DL10 blinkt 6mal und zeigt den vollen Speicher an (62
vorhandene Codes).
3 - Anschließend bleibt die LED-Anzeige DL1 10 Sekunden für die Programmierung aktiv und
erlaubt somit die vollständige Löschung aller Codes.
4 - Erneut DIP 1 und DIP 2 auf AUS stellen.
5 - Ende des Vorgangs.
F-
PROGRAMMIERUNG FUNKCODES FÜR DIE FUSSGÄNGERÖFFNUNG (MAX. 62 CODES - NUR MODELLE CRX)
Die Programmierung erfolgt nur bei geschlossenem Tor.
1-D
IP 1 auf ON und anschließend DIP 2 auf ON stellen.
2 - Die rote LED-Anzeige DL1 für die Programmierung blinkt mit einer Frequenz von 1 s ON
und 1 s OFF 10 Sekunden lang.
3 - Die Fernsteuerungs-Taste (normalerweise Kanal B) innerhalb der vorgeschriebenen Zeit
von 10 Sekunden drücken. Wenn die Fernsteuerung korrekt programmiert worden ist,
blinkt die LED-Anzeige DL10 (Grün).
4-
Die Programmierzeit der Codes verlängert sich automatisch, damit die nächste
Fernbedienung programmiert werden kann.
5 - Um die Programmierung abzuschließen, 10 Sekunden abwarten oder die Taste PROG
drücken. Die rote LED-Anzeige erlischt.
6 - E rneut DIP 1 und DIP 2 auf OFF stellen.
ANMERKUNG: WENN DIE LED-ANZEIGE DL1 STÄNDIG RASCH WEITERBLINKT,
BEDEUTET DAS, DASS DIP 1 NOCH AUF ON STEHT UND JEDER WEITERE
VORGANG UNMÖGLICH IST.
7 - Ende des Programmiervorgangs.
VORGEHEN ZUR VOLLSTÄNDIGEN LÖSCHUNG DER FUNKCODES FÜR FUSSGÄNGERÖFFNUNG
Die Löschung kann nur bei geschlossenem Tor erfolgen.
1 - DIP 1 auf ON und anschließend DIP 2 auf ON stellen.
2 - Die rote LED-Anzeige DL1 für die Programmierung blinkt mit einer Frequenz von 1 s ON
und 1 s OFF 10 Sekunden lang.
3 - Die Taste PROG. 5 Sekunden lang gedrückt halten. Die Löschung des Speichers wird
durch zweimaliges Blinken der grünen LED-Anzeige DL10 angezeigt.
4 - Die rote LED-Anzeige DL1 bleibt für die Programmierung aktiv und es ist jetzt möglich,
neue Codes wie oben beschrieben einzugeben.
5 - Erneut DIP 1 und DIP 2 auf OFF stellen.
6 - Ende des Programmiervorgangs.
ANZEIGE “SPEICHERKAPAZITÄT ERSCHÖPFT” FÜR DIE FUSSGÄNGER-ÖFFNUNG
Diese Anzeige erhält man nur bei geschlossenem Tor.
1 - DIP 1 auf ON und anschließend DIP 3 auf ON stellen.
2-
Die grüne LED-Anzeige DL10 blinkt 6mal und zeigt den vollen Speicher an (62
vorhandene Codes).
3 - Anschließend bleibt die LED-Anzeige DL1 10 Sekunden für die Programmierung aktiv und
erlaubt somit die vollständige Löschung aller Codes.
4 - Erneut DIP 1 und DIP 3 auf OFF stellen.
5 - Ende des Vorgangs.
FUNKTIONSWEISE DER STEUERZUSATZEINRICHTUNGEN
WARNUNG: VERBINDEN SIE STEUERUNG-ZUBEHÖR, NUR WENN ES AUF
IMPULS-MODUS. Stellen Sie sicher, dass alle anderen Arten von SteuerungZubehör (z.B. Magnetsensoren) auf IMPULS-Modus programmiert ist, da es
die Bewegung des Tores ohne aktive Sicherheiten aktiviert.
STEUERTASTE FÜR SCHRITTWEISEN BETRIEB (COM-K BUTTON)
Steht DIP 6 auf OFF =>
führt einen Befehl der Steuerreihe Öffnen-Stopp-SchließenStopp-Öffnen usw. aus.
Steht DIP 6 auf ON =>sorgt die für die Öffnung des geschlossenen Tors. Reagiert
nicht, wird die Taste während der Öffnungsbewegung gedrückt.
Wird die Taste bei offenem Tor gedrückt so wird das Tor
geschlossen, drückt man sie bei geschlossenem Tor, führt das
zur Öffnung.
ÖFFNUNGS-TASTE (COM-OPEN)
Bei stillstehendem Tor steuert diese Taste die Öffnungsfunktion an, wird sie während des
Schließvorganges gedrückt, so wird das Tor wieder geöffnet.
DIE UHR-FUNKTON DER SCHALTTASTE ÖFFNUNG
Wenn Sie eine Uhr (oder einfach einen Schalter) gelten zu öffnen und offen
zu halten, das Tor wollen, müssen Sie auf T2 24V mit fw 03 NOUP zu nehmen.
Wenn fw 03 oder höher ACHTUNG: BEI AUSFALL VON EINEM SAFETY, EINE
MINUTE NACH DIESER UHR ODER HABEN SWITCH AKTIVIERT WURDE, WIRD
TÜR OHNE SICHERHEITEN AKTIV AUF!
Diese Funktion ist besonders zur Stoßzeit nützlich, wenn der Verkehrsfluss langsam ist (zum
Beispiel bei Schichtwechsel, Notfälle im Wohn- oder Parkplatzbereich und vorrübergehend
bei Umzügen).
FUNKTION UHR ANBRINGUNGSART
Anfragen Sie T2 24V mit Firmware 02.
Durch Anschluss eines Schalter und /oder einer Uhr mit Tages/Wocheneinstellung (anstatt
der oder parallel zur Öffnungstaste “COM-OPEN”), kann das Tor in der Automatikeinstellung
offen gehalten werden, bis der Schalter gedrückt wird oder die eingestellte Uhrzeit erreicht
wurde.
Bei geöffneter Automatikeinstellung werden alle Steuerfunktionen unterdrückt.
In dem Loslassen des Schalters, oder wenn die eingestellte Zeit abgelaufen, haben Sie die
sofortige Schließung der Automation.
SCHLIESSUNGS-TASTE (COM-CLOSE)
Führt bei stillstehendem offenem Tor zur Schließung.
FERNSTEUERUNG
Steht DIP 6 auf OFF =>
führt einen Befehl der Steuerreihe Öffnen-Stopp- SchließenStopp-Öffnen usw. aus.
45
D
Steht DIP 6 auf ON =>sorgt die für die Öffnung des geschlossenen Tors. Reagiert nicht,
wird die Taste während der Öffnungsbewegung gedrückt. Wird
die Taste bei offenem Tor gedrückt so wird das Tor geschlossen,
drückt man sie bei geschlossenem Tor, führt das zur Öffnung.
TASTE ZUR FUSSGÄNGER-ÖFFNUNG (COM-PED.BUTT.)
Befehl für eine teilweise Öffnung mit nachfolgender Schließung.
Während der Öffnung der Pause oder der Schließung der Fußgänger-Öffnung, kann die
Öffnung mit jedem mit dem Steckverbinder T2 24V verbundenem Befehl geöffnet werden.
Über DIP 6 kann man die Funktionsweise der Taste zur Fußgänger-Öffnung wählen.
Steht DIP 6 auf OFF =>
führt einen Befehl der Steuerreihe Öffnen-Stopp-SchließenStopp-Öffnen usw. aus.
Steht DIP 6 auf ON =>sorgt die für die Öffnung des geschlossenen Tors. Reagiert nicht,
wird die Taste während der Öffnungsbewegung gedrückt. Wird
die Taste bei offenem Tor gedrückt so wird das Tor geschlossen,
drückt man sie bei geschlossenem Tor, führt das zur Öffnung.
ELEKTRISCHE VERRIEGELUNG (LOCK)
DIP 8 auf ON stellen, um den Befehl für die elektrische Verriegelung während der Öffnung
zu aktivieren.
FREIGABE ELEKTRISCHE VERRIEGELUNG WÄHREND DER ÖFFNUNG
DIP 9 auf ON stellen, um die Freigabe der elektrischen Verriegelung während der Öffnung zu
aktivieren (dabei muss DIP 8 auf ON stehen).
Wird bei geschlossenem Tor ein Öffnungsbefehl gegeben, so führt das Tor für 0,5s eine
Schließbewegung aus und gleichzeitig wird die elektrische Verriegelung aktiviert (gefolgt von
einer Pause von 0,5s und der Öffnung des Tors).
FREIGABE ELEKTRISCHE VERRIEGELUNG
DIP 10 auf ON stellen, um die Freigabe der elektrischen Verriegelung während der
Schließung zu aktivieren. Nach vollständiger Schließung laufen die Motoren bei voller
Spannung für 0,5s um die elektrische Verriegelung zu garantieren.
ERLEICHTERTE ENTBLOCKUNG MOTOREN
DIP 11 auf ON stellen, um die manuelle erleichterte Entblockung (DIP 10 muss dabei auf ON
stehen) auszuführen, nach der Schließung wird ein Umkehrvorgang für 0,2s durchgeführt,
um die Entblockung zu erleichtern.
FUNKTIONSWEISE SICHERHEITSEINRICHTUNGEN
FOTOZELLE (COM-PHOT)
Steht DIP 4 auf OFF =>Kommt bei geschlossenem Tor ein Hindernis in den Wirkkreis
der Fotozelle, so öffnet sich das Tor nicht. Während der Funktion
des Tors wirken die Fotozellen sowohl bei der Öffnung (mit
Wiederherstellung der Öffnungsbewegung nach einer halben
Sekunde) als auch bei der Schließung (mit Wiederherstellung
der Öffnungsbewegung nach einer Sekunde).
Steht DIP 4 auf ON =>Kommt bei geschlossenem Tor ein Hindernis in den Wirkkreis
der Fotozelle und erfolgt der Öffnungsbefehl, so öffnet sich das
Tor (während der Öffnungsphase erfolgt keine Ansteuerung
durch die Fotozellen). Die Fotozellen wirken nur in der
Schließungsphase (mit Wiederherstellung der Torumsteuerung
nach einer Sekunde, auch wenn die Fotozellen in Funktion
bleiben).
ÜBERWACHUNG DER SOFORTIGEN SCHLIESSUNG NACH PASSIEREN DER
FOTOZELLEN
Steht DIP 16 auf ON und DIP 4 auf OFF => a ktivieren sich die Fotozellen während der
Öffnung, hält das Tor an und schließt sich
nach nur 1 Sekunde nach Freigabe der
Fotozellen
Steht DIP 16 auf ON und DIP 4 auf ON => aktivieren sich die Fotozellen während der
Öffnung, so öffnet sich das Tor weiter. nach
Freigabe der Fotozellen hält das Tor für 1
Sekunde an und schließt sich dann.
Wird die vollständige Öffnung erreicht (nach Ende der Öffnungszeit), wird die
sofortige Schließung ausgeschaltet und die automatische Schließzeit aktiviert
(wenn der Trimmer TCA aktiviert ist und die LED-Anzeige DL6 leuchtet).
Kommt es während der Schließung zu einem raschen Passieren (zum Beispiel
durch einen Fußgänger) öffnet sich das Tor für 2 Sekunden, um sich anschließend
erneut zu schließen.
Steht DIP 12 auf OFF =>sofortige Schließung nach Passierten der Fotozellen
deaktiviert.
ZU BEACHTEN: Es wird empfohlen, die Funktionsweise der Fotozellen mindestens alle 6
Monate zu überprüfen.
EDGE (KONTAKTLEISTE) (COM-EDGE)
Wenn eingeschaltet, kehrt diese Funktion die Bewegung während einer Öffnung in eine
Schließbewegung um.
Wenn eingeschaltet, kehrt diese Funktion die Bewegung während einer Schließung in eine
Öffnungsbewegung um.
Bleibt die Kontaktleiste eingeschaltet, führt sie nach 2 Sekunden eine erneute Umkehr durch,
um dann eine erneute kleine Umkehr auszuführen und gibt dann den Alarm einer defekten
oder eingeschalteten Kontaktleiste (Kontakt NO).
Bleibt die Kontaktleiste eingeschaltet (Kontakt NO) wird keine Bewegung ermöglicht.
Wenn diese Funktion nicht benötigt wird, sind die COM-EDGE-Klemmen zu überbrücken.
ÜBERWACHUNG DER SICHERHEITSKONTAKTLEISTEN (A+TEST A-)
Durch den Eingang A+TEST und DIP 12 auf ON können die Kontaktleiste/n überwacht
werden.
Die Überwachung besteht aus einem Funktionstest der Kontaktleiste, welcher bei jeder
vollständigen Öffnungsbewegung des Tors durchgeführt wird. Nach jeder Öffnungsbewegung
wird daher eine Schließbewegung nur dann zugelassen, wenn die Kontaktleiste/n den
Funktionstest bestanden hat/haben.
ACHTUNG: DIE ÜBERWACHUNG DES KONTAKTLEISTE-EINGANGS KANN MIT DIP 12 AUF
ON AKTIVIERT ODER MIT DIP 12 AUF OFF DESAKTIVIERT WERDEN: DER FUNKTIONSTEST
DER KONTAKTLEISTEN IST NUR DANN MÖGLICH, WENN ES SICH UM EINE VORRICHTUNG
HANDELT, DIE MIT EINER EIGENEN STEUERLEITUNG AUSGESTATTET IST.
EINE MECHANISCHE KONTAKTLEISTE KANN NICHT ÜBERWACHT WERDEN, DAHER MUSS
DIP 12 AUF OFF GESTELLT WERDEN.
SELBSTTEST-ALARM KONTAKTLEISTE (DIP 12 ON)
Wenn die Überwachung nach vollständiger Öffnung negativ ausfällt, wird ein BlinkleuchtenAlarm ausgelöst, der aktiviert bleibt, unter dieser Bedingung wird die Schließung des Tors
nicht zugelassen. Der Normalbetrieb kann nur durch Reparatur der Kontaktleiste und durch
Drücken einer des aktivierenden Befehls wieder aufgenommen werden.
STOPP-TASTE (COM-STOP)
Das Drücken der Stopp-Taste führt bei jedem Zustand des Tors zu dessen
Stillstand.
Wird sie bei vollständig geöffneten Tor gedrückt (oder bei Fußgänger-Öffnung), wird
vorrübergehend die automatische Schließfunktion unterbrochen (wenn diese über den
Trimmer TCA aktiviert wurde und die LED-Anzeige DL6 leuchtet). Es muss daher ein erneuter
Schließbefehl gegeben werden.
Beim anschließenden Bewegungszyklus wird die automatische Schließfunktion wieder
aktiviert (wenn diese über den Trimmer TCA aktiviert wurde und die LED-Anzeige DL6
leuchtet).
ALARM STROMSENSOR
Die Steuerung T2 24V verfügt über automatische Sensoren, welche zur Bewegungsumkehr
des Tors im Falle eines Zusammenstoßes mit Personen oder Gegenständen in Konformität
mit den geltenden Normen EN führen (immer mit Prüfgerät die den Normen entsprechenden
Werte prüfen), ohne dabei besondere Einstelllungen an der Steuereinheit ausführen zu
müssen, da diese durch eine spezielle interne Software gesteuert wird.
Falls nach einem ersten Eingreifen der Stromsensoren bei Öffnung oder Schließung (nur
bei hoher Geschwindigkeit) ein zweites Eingreifen erfolgt, natürlich im umgekehrten Sinn,
schließt sich das Tor und kehrt dann für eine Sekunde seine Bewegung um.
Der Alarmzustand wird durch den Blinker angezeigt, der für eine Minute aktiv bleibt, während
dieser Zeitspanne ist eine Stabilisierung der Funktionsweise des Tores durch Drücken einer
beliebigen Befehlstaste möglich.
ARBEIT IM MANNSBEISEIN IM FALL EINES AUSFALLS DER SICHERHEITEN
Wenn die Kontaktleiste ist defekt oder diese arbeit länger als 5 Sekunden, oder wenn
die Fotozelle defekt ist oder für mehr als 60 Sekunden arbeit, die Befehle ÖFFNEN,
SCHLIESSEN, K und FUßGÄNGERZONE- TASTE im Mannsbeisein arbeiten.
Die Aktivierung dieser Meldefunktion wird durch die Programmier-LED blinkt gegeben.
Dieser Vorgang darf geöffnet oder geschlossen werden nur durch Halten der Tasten steuern.
Die Funksteuerung und automatische Schließung sind ausgeschlossen, weil ihr Betrieb nicht
an die Regeln erlaubt.
Nach der Wiederherstellung der Sicherheit , ist nach einer Sekunde automatisch in
automatischen Funktion oder Schritt für Schritt restauriert, und damit auch die Fernbedienung
und das automatische Schließen wieder möglich.
Anmerkung 1: Während dieses Vorgangs, im fall eines ausfalls der Kontaktleisten
46
D
(oder Fotozellen) der Fotozellen (oder Kontaktleisten) funktionieren noch,
Unterbrechung des Betriebs im Gange.
Anmerkung 2: Die Stoppen-Taste ist nicht als Sicherheitseinrichtung in diesem Modus
anzusehen; so wenn gedrückt oder kaputt, erlauben Sie keines Manöver.
Die “Totmannschaltung” Bedienung ist nür eine Not-Bedienung und die, für kurze
Zeit und mit der Visuell-Sicherheit der Autmatismum-Bewegung gemacht wird
sein. So bald wie möglich, muss der Fehler Schutz, für den ordnungsgemäßen
Betrieb, wiederhergestellt werden sein.
BLINKLICHT
ZU BEACHTEN: Diese Steuereinheit kann NUR BLINKER MIT BLINKKREISLAUF (ACG7061)
mit Glühbirnen zu 24V und maximal 20W speisen.
FUNKTION VORBLINKEN
DIP 5 - OFF => der Motor und der Blinker aktivieren sich gleichzeitig.
DIP 5 - ON => der Blinker aktiviert sich 3 Sekunden vor dem Motor.
ANZEIGELEUCHTE TOR GEÖFFNET (COM-SIGNAL)
Diese Anzeige hat die Aufgabe, die jeweiligen Bewegungszustände (offen, teilweise offen,
noch nicht vollständig geschlossen) des Tors anzuzeigen. Nur bei vollständig geschlossenem
Tor erlischt sie.
Während der Programmierung ist diese Anzeige aktiv.
ZU BEACHTEN: Max 3 W. Bei übermäßigen Einsatz der Tasten oder der Lampen kann die
Logistik der Steuereinheit in ihrer Funktionsweise beeinträchtigt werden, was zum Stoppen
von Bewegungsabläufen führen kann.
FUNKTIONSWEISE NACH STROMAUSFALL (OHNE BATTERIE)
Nach der Rückkehr der Netzspannung LED DL1 sich einschaltet und bleibt die ganze Zeit.
LED DL1 sich abschaltet zum Erreichen der kompletten Schließung des Tores.
Sobald die Stromversorgung wiederhergestellt ist, wird empfohlen, das Tor vollständig zu
öffnen. Das Tor sollte sich dann selbständig schließen bei automatischer Schließung oder
warten, bis der Blinker nicht mehr blinkt, um dann den Schließbefehl zu erteilen.
Dieser Vorgang dient zur Ausrichtung des Tores. Bleiben während des Stromausfalles die
Motoren blockiert und werden von ihrer normalen Schließposition entfernt, muss nach
Wiederherstellung der Stromversorgung ein kompletter Bewegungszyklus ausgeführt
werden.
Wenn der Stromausfall tritt während der Bewegung, oder mit geöffnet Tor, und der erste
Befehl die Schließungsbefehl ist, wird die Schließung mit der gesamten Phasenverschiebung
den Türen so, zuerst M2 schließt und nach Ausschaltung M1 schließt. Die separate
Bewegung der zwei Motoren verhindert die Überlappung der Türen.
TECHNISCHE EIGENSCHAFTEN
- Temperaturbereich
0 ÷ 55°C
- Feuchtigkeit
< 95% ohne
Kondensierung
- Versorgungsspannung230V~ ±10% (120V/60Hz auf
Anfrage)
- Frequenz
50/60 Hz
- Batterieversorgung
20-24Vdc
- Transformatorleistung
130VA
primär 230Vac
sekundär 18Vac
- Maximale Stromaufnahme
50 mA
- kurze Stromunterbrechungen
100ms
- Höchstleistung Kontrollleuchte Tor geöffnet24Vdc 3W (entspricht 1
Glühbirne mit 3W oder 5 LED
mit Serienwiderstand von 2,2 k
Ohm)
- Höchstbelastung am Blinker-Ausgang
24Vdc 20W
- Verfügbarere Strom für Fotozellen und Zubehör
1A ±15%
- Verfügbarere Strom auf der Funkgerätsteckverbindung 200mA
TECHNISCHE EIGENSCHAFTEN FUNKGERÄT (Modell T2 24V crx)
- Empfangsfrequenz
433,92MHz
- Widerstand
52 OHM
- Empfindlichkeit
>2,24µV
- Erregungszeit
300ms
- Entregungszeit
300ms
- Alle Eingänge müssen frei von Verunreinigungen sein, da die Speisung im Inneren der
Steckverbinder erzeugt wird, damit so die doppelte oder verstärkte Isolierung gegenüber
Teilen mit gefährlicher Spannung garantiert bleibt.
-
Eventuelle an den Ausgängen der Steuereinheit angeschlossene Außenschaltkreise
müssen ausgeführt werden, damit doppelte oder verstärkte Isolierung gegenüber Teilen
mit gefährlicher Spannung garantiert bleibt.
- Alle Eingänge werden von einem programmierten integrierten Schaltkreis gesteuert, der bei
jeder Inbetriebnahme eine Selbstkontrolle einleitet.
LÖSUNG VON PROBLEMEN
Nachdem alle Verbindungen sorgfältig dem Schema folgend ausgeführt wurden und das Tor
auf die mittlere Position gestellt wurde, das korrekte Einschalten der rot LEDs DL7 und DL8
und DL9 kontrollieren.
Im Fall, dass sich ein LED, mit dem Tor immer noch in mittlerer Position, nicht einschaltet,
wie folgt überprüfen und eventuelle, beschädigte Komponenten ersetzen.
DL7 ausgeschaltet
Fotozellen beschädigt
DL8ausgeschaltet
Sicherheitsrippe Schaden (Falls die Rippe nicht angeschlossen ist
einen Überbrückungsdraht zwischen COM und EDGE legen)
DL9ausgeschaltet
Stopp-Taste defekt (falls die Stopp-Taste nicht verbunden ist,
eine Überbrückung zwischen COM und STOP anlegen).
Während der Totmannfunktion mit DIP 1 auf ON gestellt überprüfen, dass sich während
der Öffnung von M1 und M2 die grünen LEDs DL2 und DL4 einschalten und dass bei der
Schließung von M1 und M2 die roten LEDs DL3 und DL5 aufleuchten.
Im gegenteiligen fall die Anschlüsse des betreffenden Motors invertieren.
FEHLER
LÖSUNG
Nachdem die verschiedenen Verbindungen gelegt sind und Strom angelegt wurde,
sind alle LEDs ausgeschaltet.
Die Unversehrtheit der Sicherungen F1, FUSE 1 überprüfen.
Die Sicherungen mit geleichwerteigen ersetzen.
F1 T 2ASICHERUNG ZUM TRANSFORMATORSCHUTZ (außerhalb des Steckverbinders T2 24V)
FUSE 1 8A SICHERUNG ZUM MOTORSCHUTZ
Der Motor öffnet und schließt, aber hat keine Antriebskraft und bewegt sich langsam. Regulierung der Trimmer RUN und LOW-SPEED überprüfen.
Das Tor führt die Öffnung aus, schließt aber nicht nach der Zeit, die eingestellt ist.
Kontrollieren, dass der Trimmer TCA aktiviert ist und die LED-Anzeige DL6 leuchtet.
Taste OPEN immer eingeschaltet, die Taste des OPEN-Befehls ersetzen.
Bei nichtbestandenem Autotest der Kontaktleiste, die Verbindungen zwischen Steuereinheit und
Speisegerät für die Kontaktleisten überprüfen. Achtung: verwendet man kein Speisegerät für
Kontaktleisten, Dip 12 auf OFF stellen.
Das Tor öffnet und schließt beim Betätigen der verschiedenen K, Radio, Open und
Close Tasten nicht.
Kontakt Sicherheitsrippe Schaden. Kontakt Fotozellen Schaden mit DIP 4 OFF.
Den entsprechenden Kontakt in Ordnung bringen oder ersetzen.
Das elektrische Schloss funktioniert nicht.
Vergewissern, dass DIP 8 auf ON gestellt ist.
Die LED-AnzeigeDL1 blinkt rasch und keine Bewegung wird zugelassen.
Die Dip Switch 1, 2 oder 3 auf OFF stellen.
47
D
OPTIONEN
Für die Anschlüsse und die technischen Daten der Zubehöre verweisen wir auf die entsprechenden Betriebsanleitungen.
FERNSENDER SUN
SUN 2CH
SUN CLONE 2CH
Kode ACG6052
Kode ACG6056
SUN 4CH
SUN CLONE 4CH
Kode ACG6054
Kode ACG6058
BATTERIE LADEKARTE
BATTERIE
Kode ACG4648
Batterie 2,2Ah 12V
Kode ACG9515
Wi-Fi VORRICHTUNGEN
MASTER Wi-Fi
KARTE FÜR DEN BETRIEB DES SYSTEMS OHNE KABEL
mit Verbinder - 12÷30V ac/dc
mit Endblockierung - 12÷30V ac/dc
Kode ACG6094
Kode ACG6099
NOVA Wi-Fi
FOTOZELLEN OHNE KABEL
EIN PAAR FOTOZELLEN - STÄNDER NOVA
VERTIGO Wi-Fi
Kode ACG8037
Kode ACG8039
KABELLOSE FOTOZELLE ERSETZT DIE SCHALTLEISTEN
VERTIGO Wi-Fi 8 Kode ACG8042 - VERTIGO Wi-Fi 10 Kode ACG8043
SPARK Wi-Fi
BLOCK Wi-Fi
SCHLÜSSELSCHALTER OHNE KABEL
Kode ACG6098
BLINKER OHNE KABEL
SEITENLAGER
Kode ACG7064
Kode ACG7042
E
S
DISPOSICIÒN DE LA INSTALACIÒN
❷
❸
CARACTERÍSTICAS TÉCNICAS
❹
KING 24V es un operador irreversible con una fricción eléctrica, utilizados
para desplazar cancelas con batientes de hojas con una longitud de hasta 4
m (Fig. 1).
KING 24V ha sido concebido para funcionar sin finales de carrera eléctricos
sino sólo mecánicos.
CARACTERÍSTICAS
TÉCNICAS
❺
❶
❶
❺ ❹
KING 24V
Longitud máxima anta
m
4
Peso máx anta
kg
400
Corrido max de arrastre
mm
Tiempo de abertura
s.
14÷27
Velocidad de arrastre
m/s.
0,0125
Fuerza max de empuje
N
1800
Alimentación e frequenza
24V
24V
Potencia motor
W
118
Absorcion
A
5,4
Ciclos diarios sugeridos
n°
Servicio
1 - Operador KING 24V
2 - Antena de radio
3 - Intermitente
4 - Interruptor de llave
5 - Fotocélulas esternas
150
90%
Ciclos garantizados
1
345*
n°
Engrase
200/14s
Bechem - RHUS 550
Peso motor
kg
10
Nivel de ruido
db
<70
Volume
m3
0,0184
Temperatura de trabajo
°C
-10 ÷ +55°C
Nivel de protección
IP
44
* Con el seguro mecánico incorporado que interviene durante la abertura. Si se utiliza
también el seguro mecánico que interviene durante el cierre, opcional, la carrera máxima
de remolque se reduce de 50 mm.
NEGRO 1
Conécte a J5 o J6 terminales +
NEGRO 2
Conécte a J5 o J6 terminales -
Mesures en mm
2
49
E
S
INSTALACIÓN
CONTROLES DE LA PRE-INSTALACIÓN
La puerta de batiente debe fijarse sólidamente a las bisagras de las columnas y no debe
balancearse durante el movimiento.
Antes de proceder a la instalación de KING 24V, es prudente verificar todos los espacios
necesarios para emplazarlo. Si la cancela se presenta como en la Fig. 1, no hace falta
efectuar ninguna modificación.
N.B. Es obligatorio adecuar las características de la cancela a las normas y
leyes vigentes.
La puerta puede ser automatizada sólo si se encuentra en buen estado y responde a la
norma EN 12604.
- La puerta no tiene que tener puertas peatonales. De lo contrario se tendrán que tomar
las oportunas precauciones de acuerdo con el punto 5.4.1 de la EN12453 (por ejemplo
impedir el movimiento del motor cuando la puertecilla está abierta, gracias a un
microinterruptor debidamente conectado a la central).
- No hay que generar puntos donde se pueda quedar atrapado (por ejemplo entre la
puerta de la cancela y la verja).
L as columnas de la verja tienen que llevar en su parte superior unas guías antidescarrilamiento para evitar desenganches involuntarios.
- No tiene que haber topes mecánicos por encima de la verja porque no son
suficientemente seguros.
3
Componentes a instalar según la norma EN12453
USO DEL CIERRE
Personas expertas
(fuera de un área
pública*)
Personas
expertas
(área pública)
Uso ilimitado
en presencia de alguien
A
B
non posivel
con impulsos a la vista
(ej. sensor)
CoE
CoE
C e D, o E
con impulso no a la vista
(ej. telemando)
CoE
C e D, o E
C e D, o E
C e D, o E
C e D, o E
C e D, o E
TYPO DE MANDO
automatico
4
*un ejemplo típico son los cierres que no dan a la calle.
A: Pulsador de mando en presencia de alguien, (es decir con acción mantenida),
como cód. ACG2013.
B: Interruptor de llave en presencia de alguien, como cód. ACG1010.
C: Regulacion de la fuerza del motor.
D: Nervaduras como cód. ACG3010 y / o otros dispositivos que limitan las fuerzas
entre limites de las normas EN 12453 - Appendix A.
E: Fotocélulas, como cód. ACG8026 (Da applicare cada 60÷70 cm por toda la altura
de la puerta hasta un máximo de 2,5 m (EN 12445 punto 7.3.2.1).
5
engrasar
cuidadosamente
6
DESBLOQUEO DE URGENCIA
En el caso de falta de corriente, para poder operar la cancela manualmente es suficiente
introducir la respectiva llave y girarla 2 veces en sentido antihorario (Fig. 3).
Para poder realizar en modo seguro el desplazamiento manual de la puerta hay que
controlar que:
- Las manillas de la puerta que se han proporcionado sean idóneas;
- Estas manillas no estén posicionadas en modo de crear puntos de peligro durante su
utilizo;
- El esfuerzo manual para mover la puerta no debe superar los 225N para las cancelas
colocadas en lugares privados y los 390N para las cancelas colocadas en sitios
comerciales e industriales (valores indiacados en el punto 5.3.5 de la norma EN 12453).
SÍ !
Asegúrese de apretar
el tornillo que sujeta el
soporte al operador, de
modo que puede girar
libremente.
FIJACIÓN DEL ENGANCHE DEL MOTOR A LA COLUMNA
Instalando el KING 24V es necesario respetar algunas medidas par obtener un correcto
desplazamiento de la puerta.
Si la columna es de hierro se le puede soldar directamente el enganche.
Si la columna es de cemento se utiliza una plancha y se la fija con cuatro tornillos de
expansión de Ø 8 mm.
En el caso de que la pared se encuentre paralela a la cancela cuando ésta se encuentra
abierta, puede que sea necesario crear una encajadura para el operador.
NO !
El operador no debe
variar su altura durante
el movimiento.
FIJACIÓN DEL ENGANCHE DEL MOTOR A LA CANCELA
Antes de introducir el pernio del motor en el ataque de la puerta, engrasar bien.
Soldar el enganche a la altura justa (Fig. 6, 7).
Instalar el KING 24V probando a cerrar y abrir controlando que el operador no roce la
cancela en movimiento.
50
E
S
COL
Enganche columna
Z
Y
X
S1
45
Cumplir con la medida y
asegurarse de que el operador
esté en posición horizontal
Z
X
Y
S2
ANT
Enganche cancela
Z
A
Y
B
X
S3
7
MEDIDAS A RESPETAR PARA UNA INSTALACIÓN CORRECTA
L
A
B
C
D
E
1÷1,80
45
100
100
815
90
1,81÷2,20
45
110
110
815
70
140
110
2,51*÷3,00*
90
170
3,01*÷3,50*
115
Min.÷Max
2,21÷2,50
L
Min.÷Max
a
90°
a
max
A
max
1÷1,80
1,81÷2,20
2,21÷2,50*
110°
20
T
ANT
COL
14
A
S3-Y
90
18
A
S3-X
815
90
20
A
S1-Z
140
815
115
25
B
S2-Y
200
140
815
115
27
B
S2-Y
B
C
D
E
ANT
COL
90
140
815
90
20
A
S1-Z
100
130
815
90
21
A
S2-Y
110
140
815
115
24
B
S1-Y
* Además, a los 2,5 metros de longitud de la puerta tiene
que colocarse una electrocerradura para asegurarse
un eficaz cierre.
En el caso de que el pilar fuera demasiado ancho y no fuese
posible instalar el electroreductor respetando la medida (B), es
indispensable crear una encajadura en el pilar o desplazar la
cancela hacia la esquina.
sec
T
sec
ANT
Enganche cancela
A
B
COL
Enganche columna
Z
Y
X
S1
MEDIDAS A RESPETAR CON DOS SEGURO MECÁNICO
L
Min.÷Max
a
1÷1,80
1,81÷2,20
2,21÷2,50
90°
2,51*÷3,00*
L
Min.÷Max
a
A
C
D
E
45
100
100
775
90
14
45
110
110
775
90
70
140
110
775
115
70
160
140
775
115
B
C
D
E
A
max
1÷1,80
1,81÷2,20
2,21÷2,50*
51
110°
T
B
max
20
ANT
COL
A
S3-Y
18
A
S3-X
20
B
S1-Z
25
B
S1-Y
ANT
COL
sec
T
sec
90
140
775
90
20
A
S1-Z
100
130
775
90
21
A
S2-Y
110
140
775
115
24
B
S1-Y
E
S
SEGURO MECÁNICO
Cód. ACG8089
El seguro mecánico opcional para detener el cierre en caso de que la cancela no tenga
un seguro de tierra (Fig. 8).
8
AJUSTE DE LOS FINALES DE CARRERA MECÁNICOS
Para posicionar los seguros se tiene que operar como en el esquema (Fig. 9).
Para poder obtener la abertura deseada es suficiente mover el seguro (A) y bloquearlo
con una llave fija n° 13.
Para poder obtener el cierre deseado se tendrá que mover el seguro (B) (OPCIONAL) y
bloquearlo con una llave fija n° 13.
9
MANTENIMIENTO
Estas operaciones deben ser efectuadas exclusivamente por personal especializado y con el
motor desconectado de la alimentación eléctrica.
Todos los años, engrasar las bisagras y controlar la fuerza de empuje ejercida por el
motorreductor sobre la puerta.
Cada dos años, se aconseja sustituir el aceite y lubricar la tuerca de husillo con grasa de
silicona.
10
52
T2 24V
T2 24V CRX
CONEXIONES ELÉCTRICAS
cód. AC07088
cód. AC07089
24Vdc 0,8A ± 15% para ACCESSORIOS
24Vdc 0,8A ± 15% para AUTOTEST COSTAS
PEATONAL
PASSO PASSO
CERRADURA
ELÉCTRICA
FOTOCÉLULAS
COMÚN
COSTAS
LED
INTERMITENTE
24Vdc 20W
ALIMENTACION
230Vac 50Hz
FUSIBLE
T2A
TRANSFORMADOR
R=2,2K 1/4W
COMÚN
CIERRE
APERTURA
STOP
ANTENA
MASA
ANTENA
M1
M2
53
E
S
E
S
J1
NF
Alimentación 230 Vac 50/60 Hz - externa a la tarjeta (120V/60Hz bajo pedido)
J2
COM.
Común de los contactos
CLOSE
Contacto para impulsos de cierre (NA)
OPEN
Contacto para impulsos de apertura (NA)
STOP
Contacto para impulsos de stop (NC)
AERIAL
Antena radio
SIGNAL
Indicador luminoso de cancela abierta y señal del estado de
funcionamiento con batería y baterías descargadas (24Vdc
3W máx)
J3
A+TEST
Positivo para alimentación autotest costa
EDGE N.C.
Contacto costa (NC)
COM.
Común de los contactos
PHOTO N.C.
Contacto de las fotocélulas (NC)
K BUTT.
Contacto para impulsos individuales (NA)
PED. BUTT.
Contacto del mando abertura peatonal (NA)
A+
Positivo para alimentación accesorios 24Vdc
A-
Negativo para alimentación accesorios 24Vdc
LOCK
Conexión cerradura eléctrica (MAX 15W 12V)
A - CONEXIÓN
J2
J1
F1
J3
TRANSFORMER
J4
FUSE 1
J9
J10
J5
Conexión fase negativa del intermitente de 24Vdc (cód.
ACG7061) Cuidado con la polaridad
J4
SECONDARY
TRANSFORMER
Conector para transformador secundario 18 Vac
J5
MOTOR 1
Conexión MOTOR 1 (sin polaridad)
J6
MOTOR 2
Conexión MOTOR 2 (sin polaridad)
SW T2 24V
Conector dedicado para la programación en fábrica. ¡NO
TOCAR EL PUENTE! ¡SI ES REMOVIDO EL OPERADOR NO
FUNCIONA!
SW RADIO
Conector dedicado para la programación en fábrica (sólo
para los modelos CRX) ¡NO TOCAR EL PUENTE! ¡SI ES
REMOVIDO EL SISTEMA DE RADIO NO FUNCIONA!
J7
J8
J7
J9
RADIO
Módulo radio incorporado (modelo CRX), o conector para
radio receptor RIB con engranaje con alimentación de 24Vdc
J10
BATTERY
CHARGER
Conector para tarjeta para la recarga de batería de 24Vdc
(cód. ACG4648)
TR1
TRIMMER RUN
Trimmer de reglamento de la alta velocidad
TR2
TRIMMER LOW
SPEED
Trimmer de reglamento de la velocidad lenta
TR3
TRIMMER TCA
Trimmer de reglamento del tiempo de esperada antes de
tener del cierre automático (por defecto NO HABILITADO y
LED DL6 APAGADO)
B - CONFIGURACIÓN
DIP 1
DIP 2
DIP 3
DIP 1-2
DIP 1-3
DIP 2-1
DIP 4
DIP 5
DIP 6
DIP 7
DIP 8
DIP 9
DIP 10
DIP 11
DIP 12
DIP 13
DIP 14
DIP 15
J6
J8
TR3
S3
TR1
( ON) - CONTROL DEL SENTIDO DE ROTACIÓN DEL MOTOR (PUNTO C)
(ON) - PROGRAMACIÓN TIEMPOS (PUNTO D)
(ON) - HABILITACIÓN PARA LA LIBERACIÓN DE LAS PUERTAS DURANTE LAS
FASES DE DESACELERACIÓN, APERTURA Y CIERRE TOTAL (EN RESPETO DE LAS
PRUEBAS DE IMPACTO SEGÚN LA NORMA EN12453)
MEMORIZACIÓN/CANCELACIÓN DE LOS CÓDIGOS DE RADIO PARA MANDO DE
APERTURA TOTAL (SOLO MODELOS CRX) (PUNTO E)
MEMORIZACIÓN/CANCELACIÓN DE LOS CÓDIGOS DE RADIO PARA MANDO DE
APERTURA PEATONAL (SOLO MODELO CRX) (PUNTO F)
PROGRAMACIÓN DE LOS TIEMPOS DE APERTURA PEATONAL
MICROINTERRUPTORES DE GESTIÓN
Fotocélulas siempre activas (OFF) - Fotocélulas activas solo en cierre (ON)
Preintermitencia (ON) - Intermitencia normal (OFF)
Mando impulso individual (K BUTT) y Receptor radio paso paso (OFF) - automático (ON)
Funcionamiento con sensor de corriente (ON-activado) Funcionamiento por tiempo (OFFactivado).
Habilitación cerradura eléctrica (ON-activado)
Habilitación golpe de desenganche de la cerradura eléctrica (ON-activada)
Habilitación golpe de desenganche de la cerradura eléctrica (ON- activado)
Habilitación desbloqueo facilitado (ON-activada)
Habilitación TEST monitorización costa (ON- activado).
Selección funcionamiento con 1 o 2 motores (por defecto OFF 2 motores)
KING 24V - ON
KING 24V - OFF
TR2
S3
PROG
Pulsador para la programación
FUSE 1
T8A
Fusible para la protección de los motores
F1
T2A
Fusible para la protección del transformador
DIP 16 CIERRE IMMEDIATO TRAS HABER TRANSITADO DELANTE DE LAS FOTOCÉLULAS
ONHABILITADA
OFFDESHABILITADA
JP1 => Verificare che il ponticello sia inserito!
JP2 => Verificare che il ponticello sia inserito!
JP3 => Verificare che il ponticello sia inserito!
PROG => S3 Pulsante per la programmazione
REGULACIONES
ATENCIÓN: PONER EL DIP 3 EN ON, SOLO DESPUÉS DE HABER TERMINADO TODAS LAS
PROGRAMACIÓNES.
NOTA: CON DIP 3 (ON) SE HABILITA LA FUNCIÓN DE BREVE INVERSIÓN DE LAS PUERTAS
DESPUÉS DEL IMPACTO ESTA BREVE INVERSIÓN DE LAS PUERTAS PERMITE REDUCIR A
CERO LA FUERZA ESTÁTICA DENTRO DE LOS 5 SEGUNDOS INDICADOS POR LA NORMA
EN12453 EN EL PUNTO A.2.2 (FUERZAS ESTÁTICAS ADMISIBLES) PERMITIENDO, POR LO
TANTO, RESPETAR LAS PRUEBAS DE IMPACTO INDICADAS EN LA NORMATIVA EN12453.
EN CASO DE QUE NO SEA NECESARIO OBEDECER LA NORMA ARRIBA DESCRITA, BASTA
COLOCAR EL DIP 3 EN POSICIÓN OFF. EN ESTE CASO LAS PUERTAS SE DETENDRÁN SIN
INVERTIR EL MOVIMIENTO.
TRIMMER RUN (TR1) Regulador electrónico de la alta velocidad
Con este trimmer es posible regular la velocidad del motor (por defecto se configura al máximo de la
velocidad). La regulación resulta de gran utilidad, pues permite que la automatización sea conforme
a las normas europeas en materia de impactos.
54
E
S
TRIMMER LOW SPEED (TR2) Regulador electrónico de la velocidad lenta en acercamiento
La regulación de la velocidad lenta se realiza actuando sobre el Trimmer LOW SPEED mediante
el cual se modifica la tensión de salida a los extremos del/ de los motor/es (girándolo en sentido
horario se aumenta la velocidad). La regulación se realiza para determinar la correcta velocidad
de final de apertura y final de cierre, en base a la estructura de la cancela, o en presencia de
rozamientos leves, que podrían comprometer el correcto funcionamiento del sistema.
TRIMMER DE CIERRE AUTOMATICO TCA (TR3) TOTAL O PEATONAL por defecto NO
HABILITADO y LED DL6 APAGADO (TRIMMER GIRADO COMPLETAMENTE EN SENTIDO
ANTIHORARIO)
Con este trimmer es posible realizar la regulación del tiempo, antes de que se produzca el cierre
automático total o peatonal. Se obtiene solo con la puerta completamente (total) o parcialmente
(peatonal) abierta y el led DL6 encendido (con trimmer girado en sentido horario).
El tiempo de pausa puede ser regulado por un mínimo de 2 segundos y un máximo de 2 minutos.
SEÑALIZACIONES LED
DL1 programación activada (rojo)
DL2 cancela en apertura M2 (verde)
DL3 cancela en cierre M2 (rojo)
DL4 cancela en apertura M1 (verde)
DL5 cancela en cierre M1 (rojo)
DL6 señalización del tiempo de cierre automático (rojo)
DL7 contacto fotocélulas (NC) (rojo)
DL8 contacto costa (NC) (rojo)
DL9 mando pulsador STOP (NC) (rojo)
DL10 programación códigos de radio (verde)
FUSIBLES
Fuse 1 T 8AFUSIBLE PARA LA PROTECCIÓN DE LOS MOTORES
F1 T 2AFUSIBLE PARA LA PROTECCIÓN DEL TRANSFORMADOR (externo a la tarjeta T2 24V)
C - CONTROL DEL SENTIDO DE ROTACIÓN DEL/DE LOS MOTOR/ES
1 - Coloque DIP 1 en posición ON => El led DL1 comienza a parpadear.
2 - Presione y mantenga presionado el pulsador PROG. (ahora el movimiento se lleva a cabo en
presencia de personas, abre-stop-cierra-stop-abre-etc.) => LOS LED VERDES DL2 y DL4 se
encienden y las puertas de la cancela se abren con un desfase fijo de 2 segundos. Si se cierran
en lugar de abrirse, libere el pulsador e invierta los dos cables del motor involucrado.
3 - Al final de la apertura, libere el pulsador PROG y realice el calibrado de los retenes mecánicos
de apertura (presentes en el operador)
4 - Presione y mantenga presionado el pulsador PROG => LOS LED ROJOS DL3 y DL5 se
encienden y las puertas de la cancela se cierran con un desfase de 2 segundos.
5 - Mantenga presionado el pulsador PROG hasta que la cancela no esté completamente cerrada.
6 - Deje las 2 puertas completamente cerradas para efectuar la programación de los tiempos.
7 - Vuelva a colocar DIP1 en posición OFF => El led DL1 se apaga indicando la salida del control.
NOTA: Durante este control el stop, las fotocélulas y las costas no están activas.
D-
PROGRAMACIÓN DE LOS TIEMPOS PARA 2 MOTORES (#) CON
SENSOR DE CORRIENTE HABILITADO (DIP 7 ON)
DURANTE LA PROGRAMACIÓN EL SENSOR DE CORRIENTE ESTÁ SIEMPRE ACTIVO
1 - La cancela debe estar completamente cerrada.
2 - Coloque el DIP 2 en posición ON => El led DL1 emitirá parpadeos breves.
3 - Presione el pulsador PROG. => M1 se abre.
4 - Una vez alcanzado el seguro mecánico de apertura, el SENSOR DE CORRIENTE AUTOMÁTICO
detiene M1 (con memorización del tiempo y de la corriente)=> En el mismo momento, se activa
M2 y abre.
5 - Una vez alcanzado el seguro mecánico de apertura, el SENSOR DE CORRIENTE AUTOMÁTICO
detiene M2 (con memorización del tiempo y de la corriente).
6 - Presione el pulsador PROG. => M2 se cierra.
7 - Presione el pulsador PROG. => M1 se cierra determinando el espacio de desfase entre
M2 y M1. En el mismo momento el led DL1 dejará de parpadear, indicando la salida del
procedimiento de memorización.
Desde este momento, las seguridades o los otros mandos de la cancela funcionarán
normalmente (inversiones, stop, alarmas, etc.).
8 - El cierre de las puertas será ejecutado en modalidad rápida (en base a lo que se ha configurado
en el trimmer RUN) y en proximidad del cierre total en modalidad desacelerada (en base a lo
que se ha configurado en el trimmer LOW SPEED).
9 - Al alcanzar el cierre, los sensores de corriente detienen la cancela.
10 - AL FINALIZAR LA PROGRAMACIÓN VUELVA A COLOCAR EL DIP 2 EN POSICIÓN OFF.
D - PROGRAMACIÓN DE LOS TIEMPOS PARA 1 MOTOR (M1) (#) CON
SENSOR DE CORRIENTE HABILITADO (DIP 7 ON)
ATENCIÓN: PARA GESTIONAR UN SOLO MOTOR EL DIP 13 DEBE ESTAR COLOCADO EN
POSICIÓN ON; DURANTE LA PROGRAMACIÓN EL SENSOR DE CORRIENTE ESTÁ SIEMPRE
ACTIVO.
La cancela debe estar completamente cerrada.
1 - Coloque el DIP 2 en posición ON => El led DL1 emitirá parpadeos breves.
2 - Presione el pulsador PROG. => M1 se abre.
Una vez alcanzado el seguro mecánico de apertura, el SENSOR DE CORRIENTE detiene M1 (con
memorización del tiempo y de la corriente).
3 - Presione el pulsador PROG. => M1 se cierra.
En el mismo momento el led DL1 dejará de parpadear, indicando la salida del procedimiento
de memorización. Desde este momento, las seguridades o los otros mandos de la cancela
funcionarán normalmente (inversiones, stop, alarmas, etc.).
Al alcanzar el cierre, mediante el sensor de corriente, la cancela se detiene.
4 - AL FINALIZAR LA PROGRAMACIÓN VUELVA A COLOCAR EL DIP 2 EN POSICIÓN OFF.
(#) DURANTE LA PROGRAMACIÓN LAS SEGURIDADES ESTÁN ACTIVAS Y SU INTERVENCIÓN
DETIENE LA PROGRAMACIÓN (EL LED DL1 DE INTERMITENTE CAMBIA A ENCENDIDO
FIJO). PARA REPETIR LA PROGRAMACIÓN COLOQUE EL DIP 2 EN POSICIÓN OFF, CIERRE
LA CANCELA MEDIANTE EL PROCEDIMIENTO DE “CONTROL DEL SENTIDO DE ROTACIÓN
DE LOS MOTORES” Y REPITA LA PROGRAMACIÓN ELEGIDA.
D-
PROGRAMACIÓN DE LOS TIEMPOS PARA 2 MOTORES (#) CON
FUNCIONAMIENTO POR TIEMPO (DIP 7 OFF)
1 - La cancela debe estar completamente cerrada.
2 - Coloque el microinterruptor DIP 2 en posición ON => El led DL1 emitirá parpadeos breves.
3 - Presione el pulsador PROG. => M1 se abre.
4 - Una vez alcanzado el seguro mecánico de apertura, después de un segundo, presione el
pulsador PROG. => M1 se detiene y M2 abre.
5 - Una vez alcanzado el seguro mecánico de apertura => después de 1 segundo, presione el
pulsador PROG. => M2 si detiene.
6 - Presione el pulsador PROG. => M2 se cierra.
7 - Presione el pulsador PROG. => M1 se cierra determinando el desfase entre M2 y M1.
En el mismo momento, el led DL1 dejará de parpadear, indicando la salida del procedimiento
de memorización.
Desde este momento, las seguridades o los otros mandos de la cancela funcionarán
normalmente (inversiones, stop, alarmas, etc.).
8 - Una vez finalizado el cómputo del tiempo, la cancela se detiene.
9 - AL FINALIZAR LA PROGRAMACIÓN, VUELVA A COLOCAR EL DIP 2 EN POSICIÓN OFF.
NOTA: La desaceleración se determina automáticamente por el cuadro electrónico en fase de
programación de tiempos, y se activa a aproximadamente 50÷60 cm antes de alcanzar los finales
de carrera mecánicos de apertura o cierre.
D-
PROGRAMACIÓN DE LOS TIEMPOS PARA 1 MOTOR (#) CON
FUNCIONAMIENTO POR TIEMPO (DIP 7 OFF)
ATENCIÓN: PARA GESTIONAR UN SOLO MOTOR, EL DIP 13 DEBE ESTAR COLOCADO EN
POSICIÓN ON.
1 - La cancela debe estar completamente cerrada.
2 - Coloque el microinterruptor DIP 2 en posición ON => El led DL1 emitirá parpadeos breves.
3 - Presione el pulsador PROG. => M1 se abre.
4 - Una vez alcanzado el seguro mecánico de apertura, después de un segundo, presione el
pulsador PROG. => M1 se detiene.
5 - Presione el pulsador PROG. => M1 se cierra.
En el mismo momento el led DL1 dejará de parpadear, indicando la salida del procedimiento de
memorización.
Desde este momento, las seguridades o los otros mandos de la cancela funcionarán
normalmente (inversiones, stop, alarmas, etc.).
6 - Una vez que el cómputo del tiempo finaliza, la cancela se detiene.
7 - AL FINALIZAR LA PROGRAMACIÓN VUELVA A COLOCAR EL DIP 2 EN POSICIÓN OFF.
D - PROGRAMACIÓN DE LOS TIEMPOS DE APERTURA PEATONAL (#) TANTO
PARA EL FUNCIONAMIENTO POR TIEMPO COMO PARA EL FUNCIONAMIENTO
CON SENSOR DE CORRIENTE
Con la cancela cerrada:
1 - Coloque primero el DIP2 en posición ON (el led DL1 parpadea rápidamente) y después el DIP1
en posición ON (el led DL1 parpadea lentamente).
2 - Presione el pulsador peatonal (COM-PED.BUTT) => M1 se abre.
3 - Presione el pulsador peatonal para detener la carrera (definiendo así la apertura de M1)
4 - Presione el pulsador peatonal para poner en marcha el cierre.
5 - Al alcanzar el cierre, vuelva a colocar los DIP 1 y 2 en posición OFF.
(#) DURANTE LA PROGRAMACIÓN LAS SEGURIDADES ESTÁN ACTIVAS Y SU INTERVENCIÓN
DETIENE LA PROGRAMACIÓN (EL LED DL1 DE INTERMITENTE CAMBIA A ENCENDIDO
FIJO).
PARA REPETIR LA PROGRAMACIÓN COLOQUE LOS DIP1 Y 2 EN POSICIÓN OFF,
CIERRE LA CANCELA MEDIANTE EL PROCEDIMIENTO DE “CONTROL DEL SENTIDO DE
ROTACIÓN DE LOS MOTORES” Y REPITA LA PROGRAMACIÓN ELEGIDA.
E - PROGRAMACIÓN DE LOS CÓDIGOS DE RADIO APERTURA TOTAL
(MÁX. 62 CÓDIGOS - SOLO MODELOS CRX)
La programación puede llevarse a cabo únicamente con la cancela detenida.
1 - Coloque el DIP 1 en posición ON y, sucesivamente, el DIP2 en ON
2 - El led rojo DL1 de programación parpadea con una frecuencia de 1 seg. ON y 1 seg. OFF
durante 10 segundos.
3 - Presione la tecla del mando a distancia (normalmente el canal A) dentro de los 10 segundos
programados. Si el mando a distancia se memoriza correctamente, el led DL10 (verde) emite
un parpadeo.
4 - El tiempo de programación de los códigos se renueva automáticamente para poder memorizar
el mando a distancia sucesivo.
55
E
S
5 - Para terminar la programación deje transcurrir 10 segundos o presione por un instante el
pulsador PROG. El led rojo DL1 de programación deja de parpadear
6 - Vuelva a colocar el DIP 1 en posición OFF y el DIP2 en OFF
7 - Final del procedimiento.
PROCEDIMIENTO CANCELACIÓN DE TODOS LOS CÓDIGOS DE RADIO DEDICADOS A LA
APERTURA TOTAL
La cancelación puede llevarse a cabo únicamente con la cancela detenida.
1 - Coloque el DIP 1 en posición ON y, sucesivamente, el DIP2 en ON
2 - El led rojo DL1 de programación parpadea con una frecuencia de 1 seg. ON y 1 seg. OFF
durante 10 segundos.
3 - Presione y mantenga presionado el pulsador PROG durante 5 segundos. La cancelación de la
memoria se señala mediante dos intermitencias del led verde DL10
4 - El led rojo DL1 de programación permanece activo y es posible introducir nuevos códigos
siguiendo los procedimientos arriba descritos.
5 - Vuelva a colocar el DIP 1 en posición OFF y el DIP2 en OFF
6 - Final del procedimiento.
SEÑALIZACIÓN DE MEMORIA SATURADA POR LOS CÓDIGOS DE RADIO DEDICADOS A LA
APERTURA TOTAL
La señalización se puede obtener únicamente con la cancela detenida.
1 - Coloque el DIP 1 en posición ON y, sucesivamente, el DIP2 en ON
2 - El led verde DL10 parpadea 6 veces indicando la condición de memoria saturada (62 códigos
presentes)
3 - Sucesivamente, el led DL1 de programación permanece activo por 10 segundos, permitiendo
una posible cancelación de todos los códigos.
4 - Vuelva a colocar el DIP 1 en posición OFF y el DIP2 en OFF
5 - Final del procedimiento.
F - P ROGRAMACIÓN DE LOS CÓDIGOS DE RADIO DE APERTURA PEATONAL
(MÁX. 62 CÓDIGOS - SOLO MODELOS CRX)
La programación puede llevarse a cabo únicamente con la cancela detenida.
1 - Coloque el DIP1 en posición ON y, sucesivamente, el DIP3 en ON
2 - El led rojo DL1 de programación parpadea con una frecuencia de 1 seg. ON y 1 seg. OFF
durante 10 segundos.
3 - Presione la tecla del mando a distancia (normalmente el canal B) dentro de los 10 segundos
programados. Si el mando a distancia se memoriza correctamente, el led DL10 (verde) emite
un parpadeo.
4 - El tiempo de programación de los códigos se renueva automáticamente para poder memorizar
el mando a distancia sucesivo.
5 - Para terminar la programación deje transcurrir 10 segundos o presione por un instante el
pulsador PROG. El led rojo DL1 de programación deja de parpadear
6 - Vuelva a colocar el DIP 1 en posición OFF y el DIP3 en OFF
NOTA: SI EL LED DL1 CONTINÚA PARPADEANDO RÁPIDAMENTE, SIGNIFICA QUE
EL DIP1 AÚN ESTÁ COLOCADO EN POSICIÓN ON Y CUALQUIER MANIOBRA SERÁ
DENEGADA.
7 - Final del procedimiento.
PROCEDIMIENTO DE CANCELACIÓN DE TODOS LOS CÓDIGOS DE RADIO DEDICADOS A LA
APERTURA PEATONAL
La cancelación puede llevarse a cabo únicamente con la cancela detenida.
1 - Colocar el DIP 1 en posición ON y, sucesivamente, el DIP3 en ON
2 - El led rojo DL1 de programación parpadea con una frecuencia de 1 seg. ON y 1 seg. OFF
durante 10 segundos.
3 - Presione y mantenga presionado el pulsador PROG durante 5 segundos. La cancelación de la
memoria se señala mediante dos intermitencias del led verde DL10
4 - El led rojo DL1 de programación permanece activo y es posible introducir nuevos códigos
siguiendo los procedimientos arriba descritos.
5 - Vuelva a colocar el DIP 1 en posición OFF y el DIP3 en OFF
6 - Final del procedimiento.
SEÑALIZACIÓN DE MEMORIA SATURADA CÓDIGOS DE RADIO DEDICADOS A LA APERTURA
PEATONAL
La señalización se puede obtener únicamente con la cancela detenida.
1 - Coloque el DIP 1 en posición ON y, sucesivamente, el DIP3 en ON
2 - El led verde DL10 parpadea 6 veces indicando la condición de memoria saturada (62 códigos
presentes)
3 - Sucesivamente, el led DL1 de programación permanece activo por 10 segundos, permitiendo
una posible cancelación de todos los códigos.
4 - Vuelva a colocar el DIP 1 en posición OFF y el DIP3 en OFF
5 - Final del procedimiento.
FUNCIONAMIENTO ACCESORIOS DE MANDO
ADVERTENCIA: CONECTE ACCESORIOS DE COMANDO SOLO SI IMPULSIVO
Asegúrese de que cualquier otro accesorios de comando que se instalan (por
ejemplo, sensores magnéticos) están programados en el modo de IMPULSO,
de lo contrario pueden activar el movimiento de la puerta sin tener activos los
elementos de seguridad.
PULSADOR DE MANDO PASO-PASO (COM-K BUTTON)
Si DIP 6 en OFF => Ejecute un mando cíclico de órdenes abre-stop-cierra-stop-abre etc.
Si DIP 6 en ON =>
Ejecute la apertura con cancela cerrada. Si se acciona durante el
movimento de apertura, no tiene efecto. Si se acciona con la cancela
abierta, la cierra y, si se acciona durante el cierre, la vuelve a abrir.
PULSADOR DE APERTURA (COM-OPEN)
Con la cancela detenida, el pulsador ordena el mando de apertura. Si se lo acciona durante el
cierre, vuelve a abrir la cancela.
FUNCIÓN RELOJ DEL PULSADOR DE APERTURA
Si desea aplicar un reloj (o más simplemente un interruptor) para abrir y
mantener abierta la puerta, usted tiene que tomar T2 24V con fw 03 NOUP.
Si fw 03 o superior ATENCION: EN CASO DE INCUMPLIMIENTO DE UNA
SEGURIDAD, UN MINUTO DESPUÉS DE QUE EL RELOJ O INTERRUPTOR HAN SIDO
ACTIVADOS, PUERTA SIN SEGUROS ACTIVO ABRIRÁ!
La Función Reloj es útil durante las horas pico, cuando el tráfico vehicular es lento (por ej.
entrada/salida de trabajadores, emergencias en zonas residenciales o zonas de aparcamientos y,
temporalmente, por mudanzas).
MODALIDAD DE APLICACIÓN FUNCIÓN RELOJ
Solicitar T2 24V con firmware 02.
Conectando un interruptor y/o un reloj de tipo diario/semanal (en el lugar o en paralelo al pulsador
de apertura N.O. “COM-OPEN”) es posible abrir y mantener abierta la automatización hasta que
el interruptor es presionado o el reloj permanece activo. Con la automatización abierta se inhiben
todas las funciones de mando. Liberando el interruptor, o cuando expira la hora configurada, se
obtendrá el cierre inmediato de la automatización.
PULSADOR DE CIERRE (COM-CLOSE)
Con la cancela detenida, ordena el movimiento de cierre.
MANDO A DISTANCIA
Si DIP 6 en OFF => Ejecute un mando cíclico de órdenes abre-stop-cierra-stop-abre etc.
Si DIP 6 en ON =>
Ejecute la apertura con cancela cerrada. Si se acciona durante el
movimento de apertura, no tiene efecto. Si se acciona con la cancela
abierta, la cierra y, si se acciona durante el cierre, la vuelve a abrir.
PULSADOR DE APERTURA PEATONAL (COM-PED BUTT.)
Mando dedicado a una apertura parcial y a su cierre.
Durante la apertura, la pausa o el cierre peatonal, es posible ordenar la apertura desde cualquier
mando conectado a la tarjeta T2 24V.
Mediante el DIP6 es posible elegir la modalidad de funcionamiento del pulsador de mando peatonal.
Si DIP 6 en OFF => Ejecute un mando cíclico de órdenes abre-stop-cierra-stop-abre etc.
Si DIP 6 en ON =>
Ejecute la apertura con cancela cerrada. Si se acciona durante el
movimento de apertura, no tiene efecto. Si se acciona con la cancela
abierta, la cierra y, si se acciona durante el cierre, la vuelve a abrir.
CERRADURA ELÉCTRICA (LOCK)
Coloque el DIP8 en posición ON para habilitar el mando de la cerradura eléctrica en apertura.
GOLPE DE DESENGANCHE DE LA CERRADURA ELÉCTRICA EN APERTURA
Coloque el DIP9 en posición ON para habilitar el golpe de desenganche de la cerradura eléctrica en
apertura (bajo la condición de que DIP8 esté en ON).
Con la cancela cerrada, si se presiona un mando de apertura, la cancela durante 0,5s ejecuta la
maniobra de cierre y, contemporáneamente, se activa la cerradura eléctrica (seguida por 0,5s de
pausa y por la apertura de la cancela)
GOLPE DE DESENGANCHE DE LA CERRADURA ELÉCTRICA
Coloque el DIP10 en posición ON para habilitar el golpe de desenganche de la cerradura eléctrica
en cierre. Una vez que se produjo el cierre, se gestionan por 0,5s los motores a plena tensión para
garantizar el enganche de la cerradura.
FACILITACIÓN DESBLOQUEO MOTORES
Coloque el DIP11 en posición ON para habilitar la facilitación del desbloqueo manual (bajo la
condición de que el DIP10 esté en ON); una vez que el cierre se produjo, se ejecutará una maniobra
de inversión con un tiempo fijo de 0,2s para facilitar el desbloqueo manual.
FUNCIONAMIENTO DE LOS ACCESORIOS DE SEGURIDAD
FOTOCÉLULA (COM-PHOT)
DIP 4 OFF => C on la cancela cerrada, si se interpone un obstáculo delante del rayo de las
fotocélulas, la cancela no abre. Durante el funcionamiento las fotocélulas intervienen
tanto en apertura (restableciendo el movimiento de apertura sólo después de que
las fotocélulas se liberan), como en cierre (restableciendo el movimiento inverso sólo
después de que las fotocélulas se liberan).
DIP 4 ON => Con la cancela cerrada, si se interpone un obstáculo delante del rayo de las
fotocélulas y se ordena la apertura, la cancela se abre (durante la apertura las
fotocélulas no intervendrán). Las fotocélulas intervendrán solo en fase de cierre (con
restablecimiento del movimiento inverso después de un segundo aún cuando las
mismas estén ocupadas).
GESTIÓN DE CIERRE INMEDIATO DESPUÉS DEL TRÁNSITO POR LAS FOTOCÉLULAS
56
E
S
DIP16 ON y DIP4 OFF => p asando por delante de las fotocélulas durante la apertura, la cancela se
detiene y sólo después de 1 segundo de que las fotocélulas se liberan,
la cancela se cierra.
DIP16 ON y DIP4 ON => p asando por delante de las fotocélulas durante la apertura, la cancela
continúa abriéndose y cuando las fotocélulas se liberan, la cancela
se detiene y luego de 1 segundo de pausa invierte su movimiento y
comienza a cerrarse.
Si se alcanza la apertura completa (final del tiempo de apertura), se excluye el cierre
inmediato y se activa el tiempo de cierre automático (si el trimmer TCA está habilitado
y el led DL6 está encendido).
Si durante el cierre hay tránsito rápido (ej. peatonal) la cancela se volverá a abrir por dos
segundos para después volver a cerrarse nuevamente.
DIP12 OFF => cierre inmediato deshabilitado después del tránsito por las fotocélulas
NOTA: Si recomienda comprobar el funcionamiento de las fotocélulas al menos cada 6 meses.
EDGE (COSTA) (COM-EDGE)
Durante la apertura, si está ocupada, invierte el movimiento en cierre.
Durante el cierre, si está ocupada, invierte el movimiento en apertura.
Si permanece ocupada después de la primera actividad, ejecuta una ulterior inversión después de
2 segundos, para después ejecutar una ulterior inversión pequeña y, entonces, señalar la alarma
de costa averiada u ocupada (contacto NO).
Si la costa permanece ocupada (contacto NO) cualquier movimiento es denegado.
Si no está utilizada, puentee los bornes COM-EDGE.
MONITORIZACIÓN COSTAS DE SEGURIDAD (A+TEST A-)
Mediante la entrada A+TEST y el DIP 12 ON es posible monitorizar la/s costa/s
La monitorización consiste en una Prueba Funcional de la costa, llevada a cabo al final de cada
apertura completa de la cancela.
Después de cada apertura, el cierre de la cancela, por consiguiente, se autoriza solo si la/s costa/s
han superado la Prueba Funcional.
ATENCIÓN: LA MONITORIZACIÓN DE LA ENTRADA COSTA PUEDE SER HABILITADA CON EL DIP
12 EN ON, O DESHABILITADA CON EL DIP12 EN OFF. EN EFECTO, LA PRUEBA FUNCIONAL DE LAS
COSTAS ES POSIBLE SOLO EN EL CASO DE QUE SE TRATE DE DISPOSITIVOS DOTADOS DE UN
ALIMENTADOR DE CONTROL PROPRIO.
UNA COSTA MECÁNICA NO PUEDE SER MONITORIZADA, POR TANTO, EL DIP 12 DEBE ESTAR
COLOCADO EN POSICIÓN OFF.
ALARMA DE AUTOTEST COSTA (DIP 12 ON)
Al final de la apertura, si la monitorización de la costa dio resultado negativo, se acciona una
alarma identificada por el intermitente que permanece encendido; bajo esta condición, el cierre de
la cancela no está autorizado; solo reparando la costa y presionando uno de los mandos habilitados
es posible restablecer el normal funcionamiento.
PULSADOR DE STOP (COM-STOP)
Durante cualquier operación el pulsador de STOP ejecuta la detención de la cancela.
Si se presiona con la cancela totalmente abierta (o parcialmente utilizando el mando peatonal) se
excluye temporalmente el cierre automático (si está habilitado mediante el trimmer TCA y el led DL6
encendido) Por consiguiente, es necesario dar una nueva orden para volverla a cerrar.
En el ciclo sucesivo, la función de cierre automático es reactivada (si habilitada mediante trimmer
TCA y led DL6 encendido)
ALARMA SENSOR DE CORRIENTE
La central T2 24V está dotada de sensores automáticos que invierten la marcha de la cancela
en el caso de impactos contra cosas o personas de conformidad con las normas EN vigentes
(compruebe siempre con adecuado instrumento el respeto de los valores configurados por la
norma), sin tener que efectuar particulares regulaciones en la central, en cuando gestionados por
un software especial interno.
Si después de una primera intervención del sensor de corriente en apertura o cierre (solo a
alta velocidad) se tiene una segunda intervención, obviamente en sentido contrario, la cancela
se detiene y, entonces, invierte por 1 segundo. El estado de alarma será visualizado por el
intermitente que permanecerá activo durante 1 minuto. Durante este tiempo es posible restablecer
el funcionamiento de la cancela presionando cualquier pulsador de mando.
FUNCIONAMIENTO A HOMBRE PRESENTE EN CASO DE AVERÍAS CON LOS ACCESORIOS
DE SEGURIDAD
Si el burlete de seguridad está estropeado o se queda apretado por mas de 5 segundos, o, si la
fotocelula de seguridad se estropea o se queda empeñada por mas de 60 segundos, los comandos
ABRE, CIERRE, K BUTTON y el PEATONAL, funcionaràn solo a hombre presente.
El signal de activación de este funcionamiento serà indicado por el LED de programacion que
relampaguea.
En este funciòn, será aconsentido el apertura y el cierre solo manteniendo apretados los pulsadores
de comandos. El comando radio y el cierre automatico seràn excludidos porque estas formas de
funcionamientos no son permitidas por las normas.
Una vez que los accesorios de seguridad serán reparados o vuelven a funcionar corectamente,
despues de 1 segundo, en automatico, el comando paso paso y el automatico pueden funcionar
normalmente; por lo tanto sea el comando radio de los transmisores y el cierre automatico pondràn
funcionar como programado.
Nota 1: durante el funcionamiento a hombre presente, en caso de averìas con las costas (o
fotocelulas) las fotocelulas (o costas) trabajo mediante la interrupción de la operación en
curso.
Nota 2: El pulsador de stop no es considerado una seguridad que se puede bypasar en este
funcionamiento, y por lo tanto, si viene apretrado o se rompe, no permite algùn movimiento
del portón.
La maniobra a hombre presente es exclusivamente una maniobra de emergencia y por
lo tanto, se debe utilizar por un tiempo muy corto y con la seguridad visiva sobre el
movimiento del sistema. No apenas posible, se deberà que reparar los accesorios de
seguridad por un corecto funcionamiento.
INTERMITENTE
NOTA: Este cuadro electrónico puede alimentar SOLO INTERMITENTES CON CIRCUITO
INTERMITENTE (ACG7061) con lámparas de 24V y 20W máximo.
FUNCIÓN PRE-INTERMITENCIA
DIP5 - OFF => el motor y el intermitente arrancan contemporáneamente.
DIP5 - ON => el intermitente arranca 3 segundos antes que el motor.
INDICADOR DE SEÑALIZACIÓN DE CANCELA ABIERTA (COM-SIGNAL)
Cumple la función de señalizar los estados de cancela abierta, parcialmente abierta o no del todo
cerrada. Solo cuando la cancela está completamente cerrada se apaga.
Durante la programación, esta señalización está activa.
NOTA: Máx. 3 W. Si se excede con las botoneras o con las lámparas, la lógica del cuadro
electrónico resultará comprometida con posible bloqueo de las operaciones.
FUNCIONAMIENTO DESPUÉS DE UN APAGÓN (SIN BATERÍAS)
Cuando regresa la tensión de red, el led DL1 se encende y queda encendido para todo el tiempo
en que la puerta queda abierta. Se apagará una vez que la puerta llega en posición de cierre
completo. Se recomienda abrir completamente la cancela. Deje que la cancela se cierre por sí sola
con el cierre automático o aguarde a que el intermitente deje de parpadear antes de dar una orden
de cierre. Esta operación permitirá que la cancela se realinee. De hecho, si durante el apagón
los motores han sido desbloqueados y desplazados de su posición de cierre normal, la primer
maniobra, cuando vuelve la alimentación, debe ser completa.
Si el apagon ocurre cuando la puerta está en movimiento, o cuando la puerta está abierta, el primer
comando recibido serà el de cierre. El cierre de las dos hojas se hará con el desfase total entre las
dos hoja, y por lo tanto, primero serà el Motor 2 - M2 a cerrar. Una vez que M2 se ha apagado,
el Motor 1 - M1 cerrará. Este movimiento distinto de los dos motores evitará la sopreposición de
las 2 hojas.
CARACTERÍSTICAS TÉCNICAS
- Rango de temperatura
0 ÷ 55°C
- Humedad< 95% sin condensación de aire
- Tensión de alimentación230V~ ±10% (120V/60Hz a pedido)
- Frecuencia
50/60 Hz
- Alimentación batería
20-24Vdc
- Potencia Transformador
130VA
primario 230Vac
secundario 18Vac
- Absorsión máxima
50 mA
- Microinterrupciones de red
100ms
- Potencia máxima indicador de cancela abierta24Vdc 3W (equivalente a 1 bombilla de
3W o 5 led con resistencia en serie de
2,2 k ohm)
- Carga máxima intermitente
24Vdc 20W
- Corriente disponible para fotocélulas y accesorios 1A ±15%
- Corriente disponibile en conector radio
200mA
CARACTERÍSTICAS TÉCNICAS RADIO (modelo T2 24V crx)
- Frecuencia Recepción
433,92MHz
- Impedancia
52 OHM
- Sensibilidad
2-24 µV
- Tiempo excitación
300ms
- Tiempo desexcitación
300ms
- Todas las entradas deben ser utilizadas como contactos limpios porque la alimentación se genera
internamente (tensión segura) en la tarjeta y está dispuesta de modo tal que garantice el respeto
de aislación doble o reforzada respecto de las partes bajo tensión peligrosa.
- Los posibles circuitos externos conectados a las salidas del cuadro electrónico deben efectuarse
de manera tal que garanticen el aislamiento doble o reforzado respecto de las partes bajo tensión
peligrosa.
- Todas las entradas son gestionadas por un circuito integrado programado que ejecuta un
autocontrol en cada puesta en marcha.
57
E
S
OPCIONALES
Para las conexiones y datos técnicos de los accesorios, consultar los manuales respectivos.
TELEMANDO SUN
SUN 2CH
SUN CLONE 2CH
cód. ACG6052
cód. ACG6056
SUN 4CH
SUN CLONE 4CH
cód. ACG6054
cód. ACG6058
TARJETA DE CARGA BATERÍA
BATERÍA
cód. ACG4648
Batería 2,2Ah 12V
cód. ACG9515
DISPOSITIVOS Wi-Fi
MASTER Wi-Fi
FICHA DE GESTIÓN SISTEMA SIN CABLES
con enchufe - 12÷30V ac/dc
con regleta - 12÷30V ac/dc
cód. ACG6094
cód. ACG6099
NOVA Wi-Fi
FOTOCÉLULAS SIN CABLES
PAR DE COLUMNAS NOVA
VERTIGO Wi-Fi
cód. ACG8037
cód. ACG8039
cód. ACG8043
SPARK Wi-Fi
BLOCK Wi-Fi
SELECTOR DE LLAVE SIN CABLES
FOTOCÉLULAS SIN CABLES PARA REEMPLAZAR A LA COSTA
VERTIGO Wi-Fi 8 cód. ACG8042 - VERTIGO Wi-Fi 10 cód. ACG6098
INTERMITENTE SIN CABLES
SOPORTE LATERAL
cód. ACG7064
cód. ACG7042
®
automatismi per cancelli
automatic entry systems
R.I.B. S.r.l.
25014 Castenedolo - Brescia - Italy
Via Matteotti, 162
Tel. ++39.030.2135811
Fax ++39.030.21358279 - 21358278
www.ribind.it - [email protected]
AZIENDA CON SISTEMA
DI QUALITÀ CERTIFICATO
DA DNV
COMPANY WITH QUALITY
SYSTEM CERTIFIED
BY DNV
DICHIARAZIONE DI CONFORMITÁ - DECLARATION OF COMPLIANCE
DÉCLARATION DE CONFORMITÉ - ÜBEREINSTIMMNUGSERKLÄRUNG
DECLARACIÓN DE CONFORMIDAD
Dichiariamo sotto la nostra responsabilità che il KIT KING 24V è conforme alle seguenti norme e Direttive:
Le KIT KING 24V se conforme aux normes suivantes:
We declare under our responsibility that KIT KING 24V operator is conform to the following standards:
Wir erklaeren das der KIT KING 24V den folgenden EN-Normen entspricht:
Declaramos bajo nuestra responsabilidad que el KIT KING 24V es conforme a la siguientes normas y disposiciones:
EN 301 489-1
2011
EN 55014-2
2015
EN 61000-6-1
2007
EN 301 489-3
2013
EN 60335-1
2016
EN 61000-6-2
2006
EN 300 220-1
2012
EN 60335-2-103 2010
EN 61000-6-3
2013
EN 300 220-3
2010
EN 61000-3-2
2015
EN 61000-6-4
2013
EN 55014-1
2012
EN 61000-3-3
2014
Inoltre permette un’installazione a Norme - Permit, en plus, une installation selon les normes suivants
You can also install according to the following rules - Desweiteren genehmigt es eine Installation der folgenden Normen:
Además permite una instalación según las Normas:
EN 12453
2002
EN 12445
2002
EN 13241-1
2011
Come richiesto dalle seguenti Direttive - Conformément aux Directives
As is provided by the following Directives - Wie es die folgenden Richtlinien verfügen
Tal y como requerido por las siguientes Disposiciones:
2006/95/CE
2004/108/CE
1999/5/EC
Il presente prodotto non può funzionare in modo indipendente ed è destinato ad essere incorporato in un impianto costituito da ulteriori elementi. Rientra perciò nell’Art. 6 paragrafo 2 della
Direttiva 2006/42/CE (Macchine) e successive modifiche, per cui segnaliamo il divieto di messa in servizio prima che l’impianto sia stato dichiarato conforme alle disposizioni della Direttiva.
Le présent dispositif ne peut fonctionner de manière indépendante, étant prévu pour être intégré à une installation constituée d’autres éléments. Aussi rentre-t-il dans le champ d’application
de l’art. 6, paragraphe 2 de la Directive machines 2006/42/CEE et de ses modifications successives. Sa mise en service est interdite avant que l’installation ait été déclarée conforme
aux dispositions prévues par la Directive.
This product can not work alone and was designed to be fitted into a system made up of various other elements. Hence, it falls within Article 6, Paragraph 2 of the EC-Directive 2006/42
(Machines) and following modifications, to which respect we point out the ban on its putting into service before being found compliant with what is provided by the Directive.
Dieses Produkt kann nicht allein funktionieren und wurde konstruiert, um in einen von anderen Bestandteilen zusammengesetzten System eingebaut zu werden. Das Produkt fällt deswegen
unter Artikel 6, Paragraph 2 der EWG-Richtlinie 2006/42 (Maschinen) und folgenden.
Este producto no puede funcionar de manera independiente y se tiene que incorporar en una instalación compuesta por otros elementos. Está incluido por lo tanto en el Art. 6 párrafo 2
de la Disposición 2006/42/CEE (Maquinaria) y sus siguientes modificaciones, por lo cual destacamos que está prohibido poner la instalación en marcha antes de que esté declarada
conforme a la citada Disposición.
Legal Representative
(Rasconi Antonio)
59
KIT KING 24V
Denominazione Particolare
CME2042
Corona elicoidale sblocco sx
CTC1158
Spina elettrica 5 20
Chiave di sblocco
CME2041
Corona elicoidale dx serie KING
CTC1214
Spina cilindrica 8x32
ACG8089
Gruppo Fermo meccanico di chiusura OPT
CME8996
Vite s/fine KING 12/24V
CTC1258
Molla per sblocco serie KING
BA01019
Serie accessori per cilindro KING
CME9130
Vite madre KING
CTC1259
Molla trazione coperchio serie KING
BA10052
Gruppo Chiocciola serie KING
CME9785
Perno Sblocco serie KING
CTC1303
Anello di tenuta OR 158
BA10065
Gruppo semig. sup. KING completo
CME9868
Perno di traino serie KING
CTC1307
Anello di tenuta OR2037
CMO2515
Boccola 12x16x12 Bronzo F7/R7
BA101024V Connettore con cavo
CAL1160
Semiguscio inferiore KING
CCA1294
Piatto colonna regolabile
CMO2515C
Motore KING 24V fino alla matricola 1185165 CVA1176
+ il cod. BA02515C
CVA1325
Motore KING 24V dalla matricola 1185166
DDD10MAI
CCA1351
Attacco cancello serie KING
CPL1087
Ingranaggio conico
DRL10X20I
Rondella Piana 10X20 Inox
CCA1355
Angolare attacco a colonna (2 pezzi)
CPL1157
Tappo per fermo meccanico serie KING
DRL10X30I
Rondella Piana 10X30 Inox
CCA1379
Forcella posteriore in acciaio
CPL1161
Ingranaggio conico serie KING
DRL12X24Z Rondella Piana 12X24
Cilindretto per serratura serie KING
Dado Autob. M10 Alto Inox
CCM6005ZZ Cuscinetto motore 6005ZZ
CRS62042R Cuscinetto 6204/2RS
DTB6X35
CEL1425
Condensatore 10µF 450V x serie 230V/50
CTC1004
Chiavetta 6 6 12
DTC55X50Z Vite TC Croce 5,5x50
CEL1426
Condensatore 35µF 450V x serie 120V/60
CTC1008
Chiavetta 6 6 30
DTE10X20I
Vite TCEI 6X30 Inox UNI5931
CME1166
Adattat. motore KING 24V
CTC1119
Seeger E17
DTE8X30I
Vite TE 8X30 Inox UNI5739
CME1299
Perno per ingranaggio serie KING
CTC1120
Seeger E20
DTM10X40I
Vite TE 10X40 Inox UNI 5737
CTC1123
Seeger E25
Vite TCEI M6x35 zinc.
Questo prodotto è stato completamente progettato e costruito in Italia · Ce produit a été complètement développé et fabriqué en Italie · This product has been
completely developed and built in Italy · Dieses Produkt wurde komplett in Italien entwickelt und hergestellt · Artìculo totalmente proyectado y producido en Italia
®
automatismi per cancelli
automatic entry systems
25014 CASTENEDOLO (BS) - ITALY
Via Matteotti, 162
Tel. +39.030.2135811
Fax +39.030.21358279
www.ribind.it - [email protected]
8 0 2 8 2 6 5 128521 >
Cod. CVA2247 - 21072016 - Rev. 16