advertisement

T2 24V | Manualzz

PRINCE 24V

Brevettato - Patented

N. 1 503 019 - US 7,000,353 B2

con / avec / with / mit

T2 24V

OPERATORE PER CANCELLI A BATTENTE

OPÉRATEUR POUR PORTAILS À BATTANT

OPERATOR FOR LEAF GATES

TORANTRIEB FÜR FLÜGELTORE

OPERADOR PARA CANCELAS DE BATIENTE

Operatore

Operateur

Operator

Torantrieb

Operador

PRINCE 24V

Alimentazione

Alimentation

Power Supply

Stromspannung

Alimentacion

230V 50/60Hz

120V 60Hz

Peso max anta

Poids maxi battant

Max leaf weight

Max. Torgewicht

Peso max hoja

250 kg / 550 lbs

Spinta

Poussée

Thrust

Schubkraft

Empuje

100 kg / 220 lbs

Spinta max

Poussée maxi

Max thrust

Max Schubkraft

Empuje max.

140 kg / 309 lbs

Codice

Code

Code

Code

Codigo

AA14031 a richiesta/on request

I

ISTRUZIONI DI SICUREZZA IMPORTANTI PER

L’INSTALLAZIONE

ATTENZIONE - PER LA SICUREZZA DELLE PERSONE È IMPORTANTE CHE

VENGANO SEGUITE TUTTE LE ISTRUZIONI

CONSERVARE CON CURA QUESTE ISTRUZIONI

1° - Se non è previsto nel quadro elettronico, installare a monte del medesimo un’interruttore di tipo magnetotermico (onnipolare con apertura minima dei contatti pari a 3 mm) che riporti un marchio di conformità alle normative internazionali. Tale dispositivo deve essere protetto contro la richiusura accidentale (ad esempio installandolo entro quadro chiuso a chiave).

2° - Per la sezione ed il tipo dei cavi la RIB consiglia di utilizzare un cavo di tipo

H05RN-F con sezione minima di 1,5 mm 2 e comunque di attenersi alla norma

IEC 364 e alle norme di installazione vigenti nel proprio Paese.

3° - Posizionamento di un’eventuale coppia di fotocellule: il raggio delle fotocellule deve essere ad un’altezza non superiore a 70 cm dal suolo e ad una distanza dal piano di movimento della porta non superiore a 20 cm. Il loro corretto funzionamento deve essere verificato a fine installazione in accordo al punto

7.2.1 della EN 12445.

4° - Per il soddisfacimento dei limiti imposti dalla EN 12453, se la forza di picco supera il limite normativo di 400 N è necessario ricorrere alla rilevazione di presenza attiva sull’intera altezza della porta (fino a 2,5 m max). Le fotocellule in questo caso sono da applicare come indicato nella norma EN 12445 punto

7.3.2.2).

N.B.: È obbligatoria la messa a terra dell’impianto.

I dati descritti nel presente manuale sono puramente indicativi.

RIB si riserva di modificarli in qualsiasi momento.

Realizzare l’impianto in ottemperanza alle norme ed alle leggi vigenti.

ISTRUZIONI IMPORTANTI DI SICUREZZA PER L’INSTALLAZIONE

ATTENZIONE - L’INSTALLAZIONE NON CORRETTA PUÒ CAUSARE GRAVI DANNI

SEGUIRE TUTTE LE ISTRUZIONI DI INSTALLAZIONE

1° - Questo libretto d’istruzioni è rivolto esclusivamente a del personale specializzato che sia a conoscenza dei criteri costruttivi e dei dispositivi di protezione contro gli infortuni per i cancelli, le porte e i portoni motorizzati

(attenersi alle norme e alle leggi vigenti).

2° - L’installatore dovrà rilasciare all’utente finale un libretto di istruzioni in accordo alla 12635.

3° - L’installatore prima di procedere con l’installazione deve prevedere l’analisi dei rischi della chiusura automatizzata finale e la messa in sicurezza dei punti pericolosi identificati (seguendo le norme EN 12453 / EN 12445).

4° - L’installatore prima di installare il motore di movimentazione deve verificare che il cancello sia in buone condizioni meccaniche e che si apra e chiuda adeguatamente.

5° - L’installatore dovrà installare l’organo per l’attuazione del rilascio manuale ad un’altezza inferiore a 1,8 m.

6° - L’installatore dovrà rimuovere eventuali impedimenti al movimento motorizzato del cancello (es. chiavistelli, catenacci, serrature ecc.)

7° - L’installatore dovrà applicare in modo permanente le etichette che mettono in guardia contro lo schiacciamento in un punto molto visibile o in prossimità di eventuali comandi fissi.

8° - Il cablaggio dei vari componenti elettrici esterni all’operatore (ad esempio fotocellule, lampeggianti, ecc.) deve essere effettuato secondo la EN 60204-1 e le modifiche a questa apportate dal punto 5.2.2 della EN 12453.

9° - movimento deve essere fatto posizionando la pulsantiera in modo che chi la aziona non si trovi in posizione pericolosa; inoltre si dovrà fare in modo che sia ridotto il rischio di azionamento accidentale dei pulsanti.

Tenete i comandi dell’automatismo (pulsantiera, telecomando etc) fuori dalla portata dei bambini. L’organo di manovra (un interruttore tenuto chiuso manualmente) deve essere in una posizione che sia visibile dalla parte guidata ma lontana dalle parti in movimento. Deve essere installato a un’altezza minima di 1,5 m.

11° - Questo apparecchio può essere utilizzato da bambini di età compresa dagli 8 anni e al di sopra e le persone con ridotte capacità fisiche, sensoriali o mentali, o mancanza di esperienza e conoscenza se sono stati controllati o istruiti all’uso dell’apparecchio in modo sicuro e capire i rischi connessi.

12° - I bambini non devono giocare con l’apparecchio.

13° - Pulizia e manutenzione utente non deve essere fatta da bambini senza supervisione.

14° - Non permettere ai bambini di giocare con i comandi fissi. Tenere i telecomandi lontano dai bambini.

15° - I dispositivi di comando fissi devono essere installati in modo che siano visibili.

16° - manutenzione dell’impianto, togliere la tensione agendo sull’apposito interruttore magnetotermico collegato a monte dello stesso.

17° - A fine installazione l’installatore dovrà assicurarsi che le parti della porta non ingombrino strade o marciapiedi pubblici.

LA DITTA RIB NON ACCETTA NESSUNA RESPONSABILITÀ per eventuali danni provocati dalla mancata osservanza nell’installazione delle norme di sicurezza e delle leggi attualmente in vigore.

2

F

INSTRUCTIONS DE SECURITE IMPORTANTES POUR

L’INSTALLATION

ATTENTION - POUR LA SECURITE DES PERSONNES, IL EST IMPORTANT DE

SUIVRE TOUTES LES INSTRUCTIONS

CONSERVER SOIGNEUSEMENT CES INSTRUCTIONS

1° - Si ce n’est pas prévu dans la centrale, installer en amont de celle-ci un interrupteur de type magnétothermique (omnipolaire avec ouverture minimum des contacts de 3 mm) qui porte une marque de conformité aux normes internationales. Ce dispositif doit être protégé contre la re-fermeture accidentelle (par exemple en l’installant dans un tableau fermé à clé).

2° - En ce qui concerne la section et le type des câbles, RIB conseille d’utiliser un câble de type H05RN-F ayant une section minumum de 1,5 mm 2 et de toute façon, s’en tenir à la norme IEC 364 et aux normes d’installation en vigueur dans le propre pays.

3° - Positionnement d’un couple éventuel de photocellules: Le rayon des photocellules doit se situer à une hauteur qui ne doit pas être supérieure à 70 cm du sol et à une distance du plan de mouvement de la porte qui ne doit pas être supérieure à

20 cm. Leur bon fonctionnement doit être vérifié en fin d’installation selon le point

7.2.1 de la EN 12445.

4° - Pour satisfaire aux limites imposées par la EN 12453, si la force de pointe dépasse la limite de la norme de 400 N, il est nécessaire de recourir au relevé de présence active sur la hauteur totale de la porte (jusqu’à 2,5 m max). - Les photocellules, dans ce cas, doivent être appliquées selon le point 7.3.2.2 de la EN 12445

N.B.: La prise de terre sur l’installation est obligatoire.

Les données décrites dans ce manuel sont purement indicatives.

RIB se réserve le droit de les modifier à tout moment.

Réaliser l’installation en conformité aux normes et aux lois en vigueur.

INSTRUCTIONS IMPORTANTES DE SECURITE POUR L’INSTALLATION

ATTENTION - UNE INSTALLATION NON CORRECTE PEUT CAUSER DE GRAVES

DOMMAGES

SUIVRE TOUTES LES INSTRUCTIONS D’INSTALLATION

1° - Ce livret d’instructions est adressé exclusivement à un personnel spécialisé qui connaît les critères de construction et les dispositifs de protection contre les accidents concernant les portails, les portes et les portes cochères motorisés (s’en tenir aux normes et aux lois en vigueur).

2° - L’installateur devra délivrer à l’utilisateur final un livret d’instruction en accord à la

EN 12635.

3° - L’installateur avant de procéder à l’installation, doit prévoir l’analyse des risques de la fermeture automatisée finale et la mise en sécurité des points identifiés dangereux (en suivant les normes EN 12453/EN 12445).

4° - L’installateur, avant d’installer le moteur de mouvement, doit vérifier que le portail de fer soit en bonnes conditions mécaniques et qu’il s’ouvre et se ferme correctement.

5° - L’installateur devra installer l’organe pour l’exécution de la relâche manuelle à une hauteur inférieure à 1,8 m.

6° - L’installateur devra retirer d’éventuels obstacles au mouvement motorisé du portail de fer (ex. verrous, serrures, etc).

7° - L’installateur devra appliquer, de façon permanente, les étiquettes qui mettent en garde contre l’écrasement, dans un endroit bien visible ou à proximité de commandes fixes éventuelles.

8° - Le câblage des divers composants électriques externes à l’opérateur (par exemple photocellules, clignotants, etc) doit être effectué selon la EN 60204-1 et les modifications apportées à celle-ci dans le point 5.2.2 de la EN 12453.

9° - Le montage éventuel d’un tableau pour la commande manuelle du mouvement doit

être fait en positionnant le tableau de façon à ce que la personne qui l’actionne ne se trouve pas en position de danger; de plus, il faudra faire en sorte que le risque d’actionnement accidentel des boutons soit réduit.

10° - Tenir les commandes de l’automatisme (tableau, télécommande, etc) hors de portée des enfants. L’organe de manoeuvre (un interrupteur tenu fermé manuellement) doit être dans une position qui soit visible de la partie guidée mais lointaine des parties en mouvement. Il doit être installé à une hauteur moindre de 1,5 m.

11° - Cet appareil peut être utilisé par des enfants âgés de 8 ans et plus et les personnes dont les capacités physiques, sensorielles ou mentales réduites, ou manquant d’expérience et de connaissances si elles sont sans surveillance ou instruction concernant l’utilisation de l’équipement en toute sécurité et de comprendre les risques encourus.

12° - Enfants ne doivent pas jouer avec l’appareil.

13° - Nettoyage et entretien utilisateur n’a pas à être effectué par des enfants sans surveillance.

14° - Ne laissez pas les enfants jouer avec les commandes fixes. Gardez la télécommande hors de portée des enfants.

15° - Les dispositifs fixes de commande doivent être installés de sorte qu’ils soient visibles.

16° - Avant l’exécution de toute opération d’installation, de réglage, d’entretien de l’installation, couper le courant en agissant sur l’interrupteur magnétothermique à cet effet, branché en amont de l’installation.

17° - A la fin de l’installation, l’installateur devra s’assurer que les parties de la porte n’encombrent pas la rue ou le trottoir public.

LA SOCIETE RIB N’ACCEPTE AUCUNE RESPONSABILITE pour d’éventuels dommages provoqués par la non-observation dans l’installation, des normes de sécurité et des lois actuellement en vigueur.

G

B

IMPORTANT SAFETY INSTRUCTIONS FOR THE

INSTALLATION

ATTENTION - FOR THE SAFETY OF PEOPLE IT IS IMPORTANT TO FOLLOW ALL

THE INSTRUCTIONS

KEEP THESE INSTRUCTIONS WITH CARE

1° - If it is not forecast in the electric gearcase, install a switch of magneto thermic type upstream, (omni polar with minimum opening of the contacts of 3 mm) with a check of conformity to the international standards. Such device must be protected against the accidental lockup (for example by installing inside a locked board).

2° - For the section and the type of the cables RIB advices to use a cable of H05RN-F type with 1,5 sqmm minimum section and, however, to keep to the IEC 364 and installation standards in force in your country.

Positioning of a possible couple of photoelectric cells: the radius of the photoelectric cells must be at a height of no more than 70 cm from the ground and at a distance not superior to 20 cm from the motion plane of the door. Their correct working must be verified at the end of the installation in accordance with the point 7.2.1 of the EN 12445

4° - To fulfill the limits set by EN 12453, and in case the peak force exceeds the normative limit of 400 N it is necessary to have recourse to the active presence survey on the whole height of the door (up to max 2,5 m) - The photoelectric cells, in this case, must be applied in accordance with the point 7.3.2.2 of the EN 12445

N.B.: The earthing of the system is obligatory.

The data described in this handbook are purely a guide.

RIB reserves the right to change them in any moment.

Carry out the system in the respect of the standards and laws in force.

IMPORTANT SAFETY INSTRUCTIONS FOR THE INSTALLATION

ATTENTION - THE INCORRECT INSTALLATION CAN CAUSE SERIOUS DAMAGES

FOLLOW ALL INSTALLATION INSTRUCTIONS

1° - This handbook is exclusively addressed to the specialized personnel who knows the constructive criteria and the protection devices against accidents for motorized gates, doors and main doors (follow the standards and the laws in force).

2° - The installer will have to issue a handbook to the final user in accordance with the 12635.

3° - Before proceeding with the installation, the installer must forecast the risks analysis of the final automatized closing and the safety of the identified dangerous points (Following the standards EN 12453/EN 12445).

4° - Before installing the motion motor, the installer must verify that the gate is in good mechanical conditions and that it adequately opens and closes.

5° - The installer must install the member for the manual release at a height inferior to 1,8 m.

6° - The installer will have to remove possible impediments to the motorized motion of the gate (eg. door bolts, sliding bolts, door locks etc.)

7° - The installer will permanently have to put the tags warning against the deflection on a very visible point or near possible fixed controls.

8° - The wiring harness of the different electric components external to the operator

(for example photoelectric cells, flashlights etc.) must be carried out according to the EN 60204-1 and the modifications to it done in the point 5.2.2 of the EN

12453.

9° - The possible assembly of a keyboard for the manual control of the movement must be done by positioning the keyboard so that the person operating it does not find himself in a dangerous position; moreover, the risk of accidental activation of the buttons must be reduced.

10° - Keep the automatism controls (push-button panel, remote control etc.) out of the children way. Command device for operating the motor (a switch manually closed) should be placed in area visible from the guided site and far from moving parts. It should be placed at least at 1,5 m height.

11° - this appliance can be used by children aged from 8 years and above and persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved

12° - children shall not play with the appliance

13° - cleaning and user maintenance shall not be made by children without supervision

14° - do not allow children to play with fixed controls. Keep remote controls away from children

15° - Fixed command devices should be installed in a well visible way.

16° - Before carrying out any installation, regulation or maintenance operation of the system, take off the voltage by operating on the special magneto thermic switch connected upstream.

17° - At the end of the installation, the installer will have to make sure that the parts of the door do not encumber streets or public sidewalks.

THE RIB COMPANY DOES NOT ACCEPT ANY RESPONSIBILITY for possible damages caused by the non observance during the installation of the safety standards and of the laws in force at present.

3

D

WICHTIGE SICHERHEITS ANLEITUNGEN FÜR DIE

INSTALLATIONEN

ACHTUNG - FÜR DIE SICHERHEIT DER PERSONEN IST ES WICHTIG, DASS ALLE

ANWEISUNGEN GENAU AUSGEFÜHRT WERDEN

INSTALLATIONSVORSCHRIFTEN BEACHTET WERDEN

1° - Wenn nicht bereits an der elektrischen Schaltzentrale vorgesehen, muss vor der

Schaltzentrale ein thermomagnetischer Schalter installiert werden (omnipolar, mit einer minimalen Kontaktöffnung von 3 mm), der ein von den internationalen Normen anerkanntes Konformitätszeichen besitzt. Solch ein Geraet muss vor Vandalismus geschuetzt werden (z.B.mit einen Schluesselkatsten in einem Panzergehaeuse).

2° - RIB empfiehlt den Kabeltyp H05RN-F mit einem minimalen Querschnitt von 1,5 mm

2 generell sollten die Normative IEC 364 und alle anderen geltenden Montagenormen des Bestimmungslandes eingehalten werden.

3° - Position des ersten paar Fotozellen: Der sollten nicht hoeher als 70 cm vom Boden sein, und sollte nicht mehr als 20 cm entfernt von der Achse des Tores sitzen (das gilt fuer Schiebe und Drehtore). In Übereinstimmung mit dem Punkt 7.2.1 der EN

12445 Norm, ihr korrektes Funktionieren muß einmal überprüft werden.

4° - In Einklang mit der Norm EN12453, ist es bei Toren notwendig eine komplette

Sicherheitslieiste zu installieren, bei denen mehr als 400 N Kraft aufgewand werden muessen, um das Tor zum anhalten zu bringen (Maximum von 2,5 m anwenden) -

Die Fotozellen müssen in diesem Fall sein beantragen außen zwischen EN 12445

Punkt 7.3.2.2).

ANMERKUNG: Die Erdung der Anlage ist obligatorisch

Die in diesem Handbuch aufgeführten Daten sind ausschließlich empfohlene Werte. RIB behält sich das Recht vor, das Produkt zu jedem Zeitpunkt zu modifizieren. Die Anlage muss in Übereinstimmung mit den gültigen Normen und Gesetzen montiert werden.

WICHTIGE SICHERHEITS ANLEITUNGEN FÜR DIE INSTALLATIONEN

WARNUNG - UNSACHGEMÄSSE INSTALLATION KANN ZU SCHWEREN

VERLETZUNGEN

ALLE INSTALLATIONSANLEITUNGEN BEFOLGEN

1° - Diese Betriebsanleitung dient ausschließlich dem Fachpersonal, welche die Konstruktionskriterien und die Sicherheits-Vorschriften gegen Unfälle für Tore,

Türen und automatische Tore kennt (geltende Normen und Gesetze beachten und befolgen).

2° - Der Monteur muss dem Endkunde eine Betriebsanleitung in Übereinkunft der

EN12635 überreichen.

3° - Vor der Installierung muss für die automatische Schließung und zur

Sicherheitsgewährung der identifizierten kritischen Punkte, eine Risiko Analyse vorgenommen werden mit der entsprechenden Behebung der identifizierten, gefährlichen Punkte. (die Normen EN 12453/EN 12445 befolgend).

4° - Vor den Bewegungsmotor zu installieren, ist es nötig die mechanischen Zustande von der Gittertür (Öffnung, Schluss, u.s.w.) zu prüfen.

5° - Das Element für den manuellen Schiebebetrieb muss bei einer geringeren Höhe von 1,80 Metern installiert sein.

6° - Der Installateur muss mögliche Verhinderungen an der Gittertürbewegung (wie z.B. Riegeln, Schlossen u.s.w.) abnehmen.

7° - Der Installateur muss ständige Etiketten, gegen die Zerdrücken Gefahr, auf einen sehr sichtbaren Punkt oder in der nähe von stationären Steuerungen anbringen.

8° - Die Verkabelung der verschiedenen externen elektrischen Komponenten zum

Operator (z.B. Fotozellen, Blinker etc.) muss nach EN 60204-1 ausgeführt werden, Änderungen davon nach Punkt 5.2.2 der EN 12453.

9° - Die eventuelle Montage einer Schalttafel für den manuellen Bewegungsbefehl muss so angebracht werden, dass der Benutzer sich nicht in einer Gefahrenzone befindet, und dass, das Risiko einer zufälligen nicht gewollten Aktivierung von

Schaltern gering ist.

10° - Alle Steuerungselemente (Schalttafel, Fernbedienung etc.) gehören nicht in

Reichweite von Kindern. Das Schalten Element (einen Schalter dass manuell geschlossen ist) muss sichtbar aus dem angetriebenen Teil sein, und muss entfernt aus dem beweglichen Teil sein. Dies Element muss bei einer Höhe von wenigsten 1,50 Metern installiert sein.

11° - Die Nutzung von diesem Gerät ist erlaubt an Kinder ab 8 Jahre alte. Es ist nötig die Personen mit physischen und Intellekt Handikapen, auf die möglichen

Gefahren zu warnen.

12° - Die Kinder muss mit diesem Gerät nicht spielen.

13° - Die Kinder muss die Reinigung und die Wartung von diesem Gerät, ohne Aufsicht, nicht machen.

14° - Die Kinder muss mit den Steuerungen und mit den Fernsteuerungen nicht spielen.

15° - Die fixe Steuerungen muss sichtbare nach der Installation sein.

16° - Vor jeglichem Eingriff, sei es Installation, Regulation oder Wartung der Anlage, muss vorher die Stromzufuhr unterbrochen werden, den dafür bestimmten

Magnetthermo-Schalter drücken, der am Eingang der Anlage installiert ist.

17° - Nach der Installation ist es nötig zu prüfen dass Teile von der Gittertür keinen

Hindernis auf Straße oder Bürgersteige verursachen.

DIE FIRMA RIB ÜBERNIMMT KEINE VERANTWORTUNG für eventuelle Schäden, die entstehen können, wenn die Installierungsvorschriften die den gültigen

Sicherheitsnormen entsprechen, nicht eingehalten werden.

E

S

IMPORTANTES INSTRUCCIONES DE SEGURIDAD PARA

LA INSTALACIÓN

ATENCIÓN PARA LA SEGURIDAD DE LAS PERSONAS ES IMPORTANTE QUE SE

OBSERVEN TODAS LAS INSTRUCCIONES

CONSERVAR CUIDADOSAMENTE ESTAS INSTRUCCIONES

1° - En el caso de que no sea previsto en la central eléctrica, instalar antes de la misma, un interruptor de tipo magnetotérmico (omnipolar con una apertura mínima de los contactos de 3 mm) que dé un sello de conformidad con las normas internacionales. Este dispositivo tiene que estar protegido contro cierres accidentales (por ejemplo instalándolo dentro de un panel cerrado a llave).

2° - Para la sección y el tipo de los cables, RIB aconseja utilizar cables de tipo H05RN-F con sección mínima de 1,5 mm2 e igualmente atenerse a la norma IEC 364 y a las normas de instalación del propio país.

3° - Posicionamiento eventual de un par de fotocélulas. El rayo de las fotocélulas no debe estar a más de 70 cm de altura desde el suelo y a una distancia de la superficie de movimiento de la puerta, no superior a 20 cm. El correcto funcionamiento tiene que ser controlado al final de la instalación de acuerdo con el punto 7.2.1 de la EN 12445.

4° - Para lograr satisfascer los límites impuestos por la EN 12453, si la fuerza de punta supera el límite normativo de 400 N, es necesario recurrir al control de presencia activa en toda la altura de la puerta (hasta a 2,5m max). - Las fotocélulas en este caso se deben colocar como indicado en la EN 12445 punto 7.3.2.2.

PS.: Es obligatorio la puesta a tierra del sistema.

Los datos descritos en el presente manual son sólamente indicativos.

RIB se reserva de modificarlos en cualquier momento.

Realizar el sistema respetando las normas y las leyes vigentes.

IMPORTANTES INSTRUCCIONES DE SEGURIDAD PARA LA INSTALACIÓN

CUIDADO: UNA INCORRECTA INSTALACIÓN PUEDE CAUSAR GRAVES DAÑOS

SEGUIR TODAS LAS INSTRUCCIONES DE INSTALACIÓN

1° - Este manual de instrucciones está exclusivamente dirigido a personal especializado que conozca los criterios de construcción y de los dispositivos de protección contra accidentes con cancelas, puertas y portales motorizados

(atenerse a las normas y a las leyes vigentes).

2° - El instalador tendrá que dar al utilizador final un manual de instrucciones de acuerdo con la 12635.

3° - El instalador antes de proceder con la instalación tiene que hacer un analisis de los riesgos del cierre automatizado final y la puesta en seguridad de los puntos identificados como peligrosos (siguiendo las normas EN 12453 / EN 12445).

4° - El instalador antes de instalar el motor de desplazamiento tiene que controlar que la cancela esté en buenas condiciones mecánicas y que se abra y se cierre en forma adecuada.

5° - El instalador tendrá que instalar el órgano para el desenganche manual a una altura inferior a 1,8 m.

6° - El instalador tendrá que quitar eventuales impedimentos para el movimiento motorizado de la cancela (ej. pistillos, cerraduras, cerrojos, etc.).

7° - El instalador tendrá que colocar de modo permanente rótulos que adviertan de la posibildad de aplastamiento, en un punto bastante visible o en las cercanías de eventuales mandos fijos.

8° - El cablaje de los varios componentes eléctricos externos al operador (por ejemplo fotocélulas, los intermitentes, etc) tiene que ser efectuado según la EN 60204-1 y a las modificas sucesivas aportadas por el punto 5.2.2 della EN 12453.

9° - El eventual montaje de un panel de mandos para la gestión del movimiento manual tiene que ser efectuado posicionando el panel en modo de que quien lo accione no se encuentre en una posición peligrosa; además se tiene que hacer en modo que sea mínimo el riesgo de accionamiento accidental de los pulsadores.

10° - Tener los mandos del automatismo (panel de mandos, mando a distancia, etc.) lejos del alcance de los niños. El òrgano de maniobra (un interruptor cerrado manualmente) tiene que estar en una posiciòn visible desde la parte de maniobra, pero lejana de las piezas en movimiento. Tiene que ser instalado en una altura mìn. de 1,5 metros.

11° - Esta unidad puede ser utilizado por niños de 8 años o más y las personas con capacidades físicas, sensoriales o mentales reducidas, o falta de experiencia y conocimientos que hayan recibido supervisión o instrucciones relativas al uso de

‘equipo de manera segura y comprender los riesgos que implica.

12° - Los niños no deben jugar con el aparato.

13° - Limpieza y mantenimiento de usuarios no tiene que ser hecho por los niños sin supervisión.

14° - No permita que los niños jueguen con los controles fijos. Mantenga los controles remotos alejados de los niños.

15° - Los mecanismos de mando fijos tienen que ser instalados de manera visible.

16° - Antes de ejecutar cualquier operación de instalación, ajuste o mantenimiento del sistema, quitar la corriente accionando el respectivo interruptor magnetotérmico conectado antes del mismo.

17° - Al final de la instalación, el instalador tendrá que asegurarse de que las partes de la puerta no estorben calles o aceras públicas.

LA EMPRESA RIB NO SE RESPONSABILIZA por eventuales daños provocados por la falta de respeto de las normas de seguridad, durante la instalación y de las leyes actualmente vigentes.

4

2

LAYOUT IMPIANTO

5 1

1 - Operatore PRINCE

2 - Antenna radio

3 - Lampeggiatore

4 - Selettore a chiave

5 - Fotocellule esterne

1 5 4

3

4

1

CARATTERISTICHE TECNICHE

PRINCE è un’operatore in grado di movimentare cancelli a battente con ante lunghe fino a 3 m e pesanti fino a 250 kg (Fig. 1).

PRINCE è stato concepito per lavorare senza finecorsa elettrici, ma solo meccanici.

necessario applicare una elettroserratura.

CARATTERISTICHE TECNICHE

Lunghezza max. anta

Peso max anta

Corsa max di traino

Tempo medio di apertura

Velocità media di traino

Alimentazione

Potenza nominale (a 71 rpm vite)

Potenza a blocco

Assorbimento nominale

Assorbimento a blocco

Forza nominale

Forza a blocco

Cicli normativi

Cicli consigliati al giorno

Servizio

Cicli consecutivi garantiti

Peso motore

Rumorosità

Volume

Temperatura di lavoro

Grado di protezione m kg mm s.

m/s n° kg db m 3

°C

IP n° n°

%

N

N

A

A

W

W

** Con fermo meccanico incorporato che interviene durante l’apertura. Se si utilizza anche il fermo meccanico che interviene durante la chiusura, opzionale, la corsa massima di traino si riduce di 30 mm.

PRINCE 24V

3

250

343**

17

0,0134

24Vdc

12

89

0,88

3,72

1000

1500

∞ - 14s/2s

60

80

60/14s

5

<70

0,0184

-30 ÷ +55°C

44

I

Misure in mm

2

5

I

INSTALLAZIONE PRINCE

CONTROLLO PRE-INSTALLAZIONE

Le ante devono essere solidamente fissate ai cardini delle colonne, non devono flettere durante il movimento e devono muoversi senza attriti.

Prima d’installare PRINCE è meglio verificare tutti gli ingombri necessari per poterlo installare.

Se il cancello si presenta come da Fig. 1 non occorrono modifiche.

È obbligatorio uniformare le caratteristiche del cancello alle norme e leggi vigenti. La porta può essere automatizzata solo se in buono stato e se rispondente alla norma EN 12604.

- L’anta non deve presentare porte pedonali. In caso contrario occorrerà prendere opportune precauzioni in accordo al punto 5.4.1 della EN12453 (ad esempio impedire il movimento del motore quando il portoncino è aperto, grazie ad un microinterruttore opportunamente collegato in centralina).

- Non bisogna generare punti di intrappolamento (ad esempio tra anta aperta del cancello e cancellata).

Non devono essere presenti fermi meccanici al di sopra del cancello perché non sono sufficientemente sicuri.

Componenti da installare secondo la norma EN12453

USO DELLA CHIUSURA

TIPO DI COMANDO

Persone esperte

(fuori da area pubblica*)

Persone esperte

(area pubblica)

Uso illimitato a uomo presente A B non possibile a impulsi in vista

(es. sensore) a impulsi non in vista

(es. telecomando) automatico

C o E

C o E

C o E

C e D, o E

C e D, o E

C e D, o E

C e D, o E C e D, o E C e D, o E

* esempio tipico sono le chiusure che non accedono a pubblica via

A: Pulsante di comando a uomo presente (cioè ad azione mantenuta), come cod.

ACG2013

B: Selettore a chiave a uomo presente, come cod. ACG1010

C: Regolazione della forza del motore

D: Coste e/o altri dispositivi di limitazione delle forze entro i limiti della norma EN12453

- Appendice A.

E: Fotocellule, es. cod. ACG8026 (Da applicare ogni 60÷70cm per tutta l’altezza della colonna del cancello fino ad un massimo di 2,5m - EN 12445 punto 7.3.2.1)

SBLOCCO DI EMERGENZA

In caso di mancanza di corrente, per poter agire manualmente sul cancello è sufficiente inserire l’apposita chiave e ruotarla di 90° in senso antiorario (Fig. 3).

Per poter eseguire in modo sicuro la movimentazione manuale dell’anta occorre verificare che:

- Siano fornite idonee maniglie sull’anta;

- Tali maniglie non siano posizionate in modo da creare punti di pericolo durante il loro utilizzo;

- Lo sforzo manuale per muovere l’anta non deve superare i 225N per i cancelli posti su siti privati ed i 390N per i cancelli posti su siti commerciali ed industriali (valori indicati nel punto

5.3.5 della norma EN 12453).

FISSAGGIO ATTACCO MOTORE A COLONNA

Installando PRINCE è necessario rispettare alcune misure per avere un corretto movimento dell’anta (Fig. 4, 5, 7, 8, 9)

Se la colonna è in ferro le si può avvitare direttamente l’attacco utilizzando quattro viti filettate

M8.

Se la colonna è in cemento fissare l’attacco con quattro viti ad espansione di Ø 8 mm.

In caso si abbia il muro parallelo al cancello quando questo è aperto, può essere necessario praticare una nicchia per dare una sede all’operatore.

FISSAGGIO ATTACCO MOTORE A CANCELLO

Proseguendo nell’installazione si deve fissare sull’anta l’attacco per il traino del cancello, osservando naturalmente le quote previste (Fig. 6, 9).

Installare PRINCE provando più volte ad aprire e chiudere controllando che il profilo coprivite non sfreghi nel cancello in movimento.

6

3

4

5

Ingrassare accuratamente

SI !

Assicurarsi di stringere il bullone che fissa l’operatore alla staffa permettendo che la stessa possa ruotare liberamente.

7

NO !

L’operatore non deve variare la sua altezza nelle varie fasi della movimentazione.

8

6

S1

Z

Y

X

Rispettare la misura e assicurarsi che l’operatore sia orizzontale

S2

Z

Y

X

COL

Attacco colonna

Z

Y

X

S3

Misure da rispettare per una corretta installazione

L

Min.÷Max

1÷3 a

A max

B C D E

T sec

COL ANT

90°

0 100 100 765 90 13,5 S2-X A

20 100 100 765 90 13,5

S2-Y A

40 100 100 765 90 13,5 S3-X A

60 110 100 765 90 14 S3-Y A

80 140 110 765 115 17 S3-X B

100 160 110 765 115 18

S3-X B

120 180 110 765 115 19,5 S3-X B

140 210 110 765 115 21,5 S1-Z B

150 220 120 765 115 23 S1-Z B

110°

20 110 140 765 90 17

S1-Y A

Misure da rispettare CON 2 FERMI MECCANICI

L

Min.÷Max

1÷3 a

A max

B C D E

T sec

COL ANT

0 100 100 730 90 13,5 S2-X A

20 100 100 730 90 13,5

S2-X A

40 100 100 730 90 13,5 S3-X A

60 110 100 730 90 14 S3-X A

90°

80 140 110 730 115 17 S3-X B

100 160 110 730 115 18

S3-X B

110 180 120 730 115 20 S1-Z B

110°

20 100 140 730 90 16 S2-Y A

ANT

Attacco anta

A

B

Qualora il pilastro fosse molto largo e non fosse possibile installare l’elettroriduttore rispettando la misura (B), è indispensabile creare una nicchia nel pilastro o spostare il cancello sullo spigolo.

9

7

I

I

FERMO MECCANICO - OPTIONAL (Cod. ACG8088)

Fermo meccanico OPTIONAL per fermare la chiusura in caso il cancello sia privo di un fermo a terra.

REGOLAZIONE FINECORSA MECCANICI

Per posizionare i fermi si deve agire come da schema (Fig. 11).

Per ottenere l’apertura desiderata è sufficiente spostare il fermo (A) e bloccarlo serrando la vite da 8mA con una chiave fissa n°13.

Per ottenere la chiusura desiderata si dovrà spostare il fermo (B) (OPZIONALE) bloccandolo come descritto per il fermo (A).

MANUTENZIONE

Da effettuare solamente da parte di personale specializzato dopo aver tolto l’alimentazione elettrica.

Ogni anno ingrassare i cardini e controllare la forza di spinta esercitata dall’operatore sull’anta.

Ogni due anni è consigliabile lubrificare la madrevite con del grasso siliconico.

COLLEGAMENTI ELETTRICI

A B

C

8

D

10

11

T2 24V cod. AC07088

T2 24V CRX cod. AC07089

ANTENNA

COMUNE

CHIUDE

APRE

STOP

CALZA

ANTENNA

LED

24Vdc 0,8A ± 15% per ACCESSORI

24Vdc 0,8A ± 15% per AUTOTEST COSTE

LAMPEGGIATORE

24Vdc 20W

PEDONALE

PASSO PASSO

FOTOCELLULE

COMUNE

COSTE

R=2,2K 1/4W

SERRATURA

ELETTRICA

ALIMENTAZIONE

230Vac 50Hz

FUSE

T 2 A

TRASFORMATORE

I

M1

M2

9

I

A - CONNESSIONI

J1

J2

J3

J4

J5

J6

J7

J8

J9

N F

COM.

CLOSE

OPEN

STOP

AERIAL

SIGNAL

A+TEST

EDGE N.C.

COM.

PHOTO N.C.

K BUTT.

PED. BUTT.

A+

A -

LOCK

SECONDARY

TRANSFORMER

MOTOR 1

MOTOR 2

SW T2 24V

SW RADIO

RADIO

B - SETTAGGI

Alimentazione 230 Vac 50/60 Hz - esterna alla scheda -

(120V/60Hz a richiesta)

Comune dei contatti

Contatto impulso di chiusura (NA)

Contatto impulso di apertura (NA)

Contatto impulso di stop (NC)

Antenna radio

Spia cancello aperto e segnalazione stato di funzionamento con batteria e batteria scarica (24Vdc 3W max)

Positivo per alimentazione autotest costa

Contatto costa (NC)

Comune dei contatti

Contatto fotocellule (NC)

Contatto impulso singolo (NA)

Contatto comando apertura pedonale (NA)

Positivo per alimentazione accessori a 24Vdc

Negativo per alimentazione accessori a 24Vdc

Collegamento elettroserratura (MAX 15W 12V)

Collegamento fase negativa lampeggiatore a 24Vdc (cod.

ACG7061) Attenzione alle polarità.

Connettore per secondario trasformatore 18 Vac

Collegamento MOTORE 1 (senza polarità)

Collegamento MOTORE 2 (senza polarità)

Connettore dedicato alla programmazione in fabbrica. NON

TOCCARE IL PONTICELLO! SE VIENE RIMOSSO L’OPERATORE

NON FUNZIONA!

Connettore dedicato alla programmazione in fabbrica (solo per modelli CRX). NON TOCCARE IL PONTICELLO! SE VIENE

RIMOSSO L’OPERATORE NON FUNZIONA!

Modulo radio incorporato (modello CRX), o connettore per radio ricevitore RIB ad innesto con alimentazione a 24Vdc

Connettore per scheda di ricarica batteria a 24Vdc (cod.

ACG4648)

Trimmer di regolazione dell’alta velocità

Trimmer di regolazione della bassa velocità

J9

J10

J8

J7

S3

REGOLAZIONI

J2 J3

J1

TR1 TR2

F1

TRANSFORMER

J4

FUSE 1

J5

J6

TR3

J10

TR1

TR2

BATTERY

CHARGER

TRIMMER RUN

TRIMMER LOW

SPEED

TRIMMER TCA TR3 Trimmer di regolazione del tempo di attesa prima di avere la chiusura automatica (DI DEFAULT NON ABILITATO E LED DL6

SPENTO)

DIP 1 (ON) - CONTROLLO SENSO DI ROTAZIONE DEL MOTORE (PUNTO C)

DIP 2 (ON) - PROGRAMMAZIONE TEMPI (PUNTO D)

DIP 3 (ON) - ABILITAZIONE RILASCIO ANTE DURANTE LE FASI DI RALLENTAMENTO, E

IN APERTURA E CHIUSURA TOTALE (PER RISPETTO DELLE PROVE DI IMPATTO

SECONDO EN12453)

DIP 1-2 MEMORIZZAZIONE/CANCELLAZIONE CODICI RADIO PER COMANDO APERTURA

TOTALE (SOLO MODELLO CRX) (PUNTO E)

DIP 1-3 MEMORIZZAZIONE/CANCELLAZIONE CODICI RADIO PER COMANDO APERTURA

PEDONALE (SOLO MODELLO CRX) (PUNTO F)

DIP 2-1 PROGRAMMAZIONE TEMPI APERTURA PEDONALE MICROINTERRUTTORI DI

GESTIONE

DIP 4 Fotocellule sempre attive (OFF) - Fotocellule attive solo in chiusura (ON)

DIP 5 Prelampeggio (ON) - Lampeggio normale (OFF)

DIP 6 Comando impulso singolo (K BUTT) e Ricevitore radio passo passo (OFF) - automatico

(ON)

DIP 7 Funzionamento con sensore di corrente (ON-attivato) Funzionamento a tempo (OFFattivato).

DIP 8 Abilitazione serratura elettrica (ON-attivato)

DIP 9 Abilitazione colpo di sgancio serratura elettrica (ON-attivata)

DIP 10 Abilitazione colpo di aggancio serratura elettrica (ON- attivato)

DIP 11 Abilitazione facilitazione sblocco (ON-attivata)

DIP 12 Abilitazione TEST monitoraggio costa (ON- attivato ).

S3 PROG

FUSE 1 T 8 A

F1 T 2 A

Pulsante per la programmazione

Fusibile di protezione motori

Fusibile di protezione trasformatore

DIP 13 Selezione funzionamento con 1 o 2 motori (di default OFF 2 motori)

DIP 14 OFF

DIP 15 OFF

DIP 16 CHIUSURA IMMEDIATA DOPO AVER TRANSITATO DAVANTI ALLE FOTOCELLULE

ON ABILITATA

OFF DISABILITATA

JP1 => Verificare che il ponticello sia inserito!

JP2 => Verificare che il ponticello sia inserito!

JP3 => Verificare che il ponticello sia inserito!

PROG => S3 Pulsante per la programmazione

ATTENZIONE: ABILITARE IL DIP 3 SOLO DOPO AVER ESEGUITO TUTTE LE

PROGRAMMAZIONI.

NOTA: CON DIP 3 (ON) SI ABILITA LA FUNZIONE DI INVERSIONE BREVE DELLE ANTE

DOPO IMPATTO.

QUESTA INVERSIONE BREVE DELLE ANTE PERMETTE DI RIDURRE A ZERO LA FORZA

STATICA ENTRO I 5 SECONDI INDICATI DALLA NORMA EN12453 AL PUNTO A.2.2

(FORZE STATICHE AMMISSIBILI) CONSENTENDO QUINDI IL RISPETTO DELLE PROVE DI

IMPATTO INDICATE SEMPRE DALLA EN12453).

IN CASO NON SUSSISTA LA NECESSITA’ DI OTTEMPERARE ALLA NORMA SOPRA

DESCRITTA, E’ SUFFICIENTE POSIZIONARE IL DIP 3 IN OFF. IN QUESTO CASO LE ANTE

SI FERMERANNO SENZA INVERTIRE IL MOVIMENTO.

10

TRIMMER RUN (TR1) Regolatore elettronico dell’alta velocità

Con questo trimmer è possibile regolare la velocità del motore (di default viene settato al massimo della velocità). La regolazione ha grande utilità per rendere l’automazione conforme alle norme europee in materia di impatti.

TRIMMER LOW SPEED (TR2) Regolatore elettronico della velocità lenta in accostamento

La regolazione della velocità lenta viene eseguita agendo sul Trimmer LOW SPEED tramite il quale si varia la tensione di uscita ai capi del/dei motore/i (ruotandolo in senso orario si aumenta la velocità). La regolazione viene eseguita per determinare la corretta velocità di fine apertura e fine chiusura in base alla struttura del cancello o in presenza di leggeri attriti che potrebbero compromettere il corretto funzionamento del sistema.

IN ON DURANTE LA PROGRAMMAZIONE IL SENSORE DI CORRENTE È SEMPRE ATTIVO.

Il cancello deve essere completamente chiuso.

1 - Mettete DIP 2 su ON => Il led DL1 emetterà dei lampeggi brevi.

2 - Premete il pulsante PROG. => M1 apre.

Raggiunto il fermo meccanico di apertura, il SENSORE DI CORRENTE ferma M1 (con memorizzazione del tempo e della corrente).

3 - Premete il pulsante PROG. => M1 chiude.

Nello stesso istante il led DL1 smetterà di lampeggiare segnalando l’uscita dalla procedura di apprendimento. Da questo momento le sicurezze o altri comandi del cancello funzioneranno normalmente (inversioni, stop, allarmi, ecc....).

Al raggiungimento della chiusura tramite il sensore di corrente il cancello si ferma.

4 -

A FINE PROGRAMMAZIONE RIMETTERE IL DIP 2 SU OFF.

(#) DURANTE LA PROGRAMMAZIONE LE SICUREZZE SONO ATTIVE ED IL LORO

INTERVENTO FERMA LA PROGRAMMAZIONE (IL LED DL1 DA LAMPEGGIANTE RIMANE

ACCESO FISSO). PER RIPETERE LA PROGRAMMAZIONE POSIZIONARE IL DIP 2 SU OFF,

CHIUDERE IL CANCELLO TRAMITE PROCEDURA “CONTROLLO SENSO DI ROTAZIONE

DEI MOTORI” E RIPETERE LA PROGRAMMAZIONE SCELTA.

TRIMMER DI CHIUSURA AUTOMATICA TCA (TR3) TOTALE O PEDONALE di default NON

ABILITATO e LED DL6 SPENTO (TRIMMER RUOTATO COMPLETAMENTE IN SENSO

ANTIORARIO)

Con questo trimmer è possibile eseguire la regolazione del tempo prima di avere la chiusura automatica totale o pedonale. Si ottiene solo con porta completamente (totale) o parzialmente

(pedonale) aperta e led DL6 acceso (con trimmer ruotato in senso orario).

Il tempo di pausa può essere regolato da un minimo di 2 secondi ad un massimo di 2 minuti.

SEGNALAZIONI LED

DL1 programmazione attivata (rosso)

DL2 cancello in apertura M2 (verde)

DL3 cancello in chiusura M2 (rosso)

DL4 cancello in apertura M1 (verde)

DL5 cancello in chiusura M1 (rosso)

DL6 segnalazione tempo chiusura automatica (rosso)

DL7 contatto fotocellule (NC) (rosso)

DL8 contatto costa (NC) (rosso)

DL9 comando pulsante STOP (NC) (rosso)

DL10 programmazione codici radio (verde)

FUSIBILI

Fuse 1 T 8A

FUSIBILE DI PROTEZIONE MOTORI

F1 T 2A FUSIBILE DI PROTEZIONE TRASFORMATORE (esterno alla scheda T2 24V)

D - PROGRAMMAZIONE TEMPI PER 2 MOTORI (#) CON FUNZIONAMENTO A

TEMPO (DIP 7 OFF)

1 - Il cancello deve essere completamente chiuso.

2 - Mettete il microinterruttore DIP 2 su ON => Il led DL1 emetterà dei lampeggi brevi.

3 - Premete il pulsante PROG. => M1 apre.

4 - Raggiunto il fermo meccanico di apertura, dopo un secondo premete il pulsante PROG.

=> M1 si ferma e M2 apre.

5 - Raggiunto il fermo meccanico di apertura => dopo 1 secondo premete il pulsante PROG.

=> M2 si ferma.

6 - Premete il pulsante PROG. => M2 chiude.

7 - Premete il pulsante PROG. => M1 chiude determinando la sfasamento fra M2 e M1.

Nello stesso istante il led DL1 smetterà di lampeggiare segnalando l’uscita dalla procedura di apprendimento.

Da questo momento le sicurezze o altri comandi del cancello funzioneranno normalmente

(inversioni, stop, allarmi, ecc....).

8 - Finito il conteggio del tempo il cancello si ferma.

9 - A FINE PROGRAMMAZIONE RIMETTERE IL DIP 2 SU OFF.

NOTA: Il rallentamento viene determinato automaticamente dal quadro elettronico in fase di programmazione tempi, e viene attivato a circa 50÷60 cm prima del raggiungimento dei finecorsa meccanici di apertura o chiusura.

C - CONTROLLO SENSO DI ROTAZIONE DEL/DEI MOTORE/I

1 - Mettere DIP 1 su ON => Il led DL1 inizia a lampeggiare.

2 - Premere e mantenere premuto il pulsante PROG. (ora il movimento é eseguito ad uomo presente, apre-stop-chiude-stop-apre-ecc.) => I LED VERDI DL2 e DL4 si accendono e le ante del cancello si aprono con sfasamento fisso di 2 sec. Se chiudono invece di aprire, rilasciare il pulsante ed invertire i due fili del motore interessato.

3 - A fine apertura rilasciare il pulsante PROG. ed eseguire la taratura dei fermi meccanici d’apertura (presenti sull’operatore).

4 - Premere e mantenere premuto il pulsante PROG => I LED ROSSI DL3 e DL5 si accendono e le ante del cancello si chiudono con sfasamento di 2 sec.

5 - Mantenere premuto il pulsante PROG fino a che il cancello non sia completamente chiuso.

6 - Lasciare le 2 ante completamente chiuse per fare la programmazione tempi.

7 - Rimettere DIP1 su OFF => Il led DL1 si spegne segnalando l’uscita dal controllo.

N.B.: Durante questo controllo lo stop, le fotocellule e le coste non sono attive.

PROGRAMMAZIONE TEMPI PER 2 MOTORI (#) CON SENSORE DI

CORRENTE ABILITATO (DIP 7 ON)

DURANTE LA PROGRAMMAZIONE IL SENSORE DI CORRENTE È SEMPRE ATTIVO.

1 - Il cancello deve essere completamente chiuso.

2 - Mettete il DIP 2 su ON => Il led DL1 emetterà dei lampeggi brevi.

3 - Premete il pulsante PROG. => M1 apre.

4 - Raggiunto il fermo meccanico di apertura, il SENSORE DI CORRENTE AUTOMATICO ferma

M1 (con memorizzazione del tempo e della corrente)=> Nello stesso momento si attiva

M2 che apre.

5 - Raggiunto il fermo meccanico di apertura, il SENSORE DI CORRENTE AUTOMATICO ferma

M2 (con memorizzazione del tempo e della corrente)

6 - Premete il pulsante PROG. => M2 chiude.

7 - Premete il pulsante PROG. => M1 chiude determinando lo spazio di sfasamento fra M2 e M1. Nello stesso istante il led DL1 smetterà di lampeggiare segnalando l’uscita dalla procedura di apprendimento.

Da questo momento le sicurezze o altri comandi del cancello funzioneranno normalmente

(inversioni, stop, allarmi, ecc....).

8 - La chiusura delle ante verrà eseguita in modalità veloce (in base a quanto da voi settato sul trimmer RUN) e in prossimità della totale chiusura in modalità rallentata (in base a quanto da voi settato sul trimmer LOW SPEED).

9 - Al raggiungimento della chiusura i sensori di corrente fermano il cancello.

10 - A FINE PROGRAMMAZIONE RIMETTERE IL DIP 2 SU OFF.

D - PROGRAMMAZIONE TEMPI PER 1 MOTORE (M1)(#)CON SENSORE DI

CORRENTE ABILITATO (DIP 7 ON)

ATTENZIONE: PER GESTIRE UN SOLO MOTORE IL DIP 13 DEVE ESSERE POSIZIONATO

11

D - PROGRAMMAZIONE TEMPI PER 1 MOTORE (#) CON FUNZIONAMENTO A

TEMPO (DIP 7 OFF)

ATTENZIONE: PER GESTIRE UN SOLO MOTORE IL DIP 13 DEVE ESSERE POSIZIONATO

IN ON

1 - Il cancello deve essere completamente chiuso.

2 - Mettete il microinterruttore DIP 2 su ON => Il led DL1 emetterà dei lampeggi brevi.

3 - Premete il pulsante PROG. => M1 apre.

4 - Raggiunto il fermo meccanico di apertura, dopo un secondo premete il pulsante PROG.

=> M1 si ferma.

5 - Premete il pulsante PROG. => M1 chiude.

Nello stesso istante il led DL1 smetterà di lampeggiare segnalando l’uscita dalla procedura di apprendimento.

Da questo momento le sicurezze o altri comandi del cancello funzioneranno normalmente

(inversioni, stop, allarmi, ecc....).

6 - Finito il conteggio del tempo il cancello si ferma.

7 - A FINE PROGRAMMAZIONE RIMETTERE IL DIP 2 SU OFF.

PROGRAMMAZIONE TEMPI APERTURA PEDONALE (#) SIA PER

FUNZIONAMENTO A TEMPO CHE CON SENSORE DI CORRENTE

A cancello chiuso:

1 - Mettere prima il DIP2 su ON (il led DL1 lampeggia velocemente) e dopo il DIP1 su ON (il led DL1 lampeggia lentamente).

2 - Premere il pulsante pedonale (COM-PED.BUTT) => M1 apre.

3 - Premere il pulsante pedonale per arrestare la corsa (definendo così l’apertura di M1).

4 - Premere il pulsante pedonale per avviare la chiusura.

5 - Al raggiungimento della chiusura rimettere i DIP1 e 2 su OFF.

(#) DURANTE LA PROGRAMMAZIONE LE SICUREZZE SONO ATTIVE ED IL LORO

INTERVENTO FERMA LA PROGRAMMAZIONE (IL LED DL1 DA LAMPEGGIANTE RIMANE

ACCESO FISSO).

PER RIPETERE LA PROGRAMMAZIONE POSIZIONARE I DIP 1 E 2 SU OFF, CHIUDERE IL

CANCELLO TRAMITE PROCEDURA “CONTROLLO SENSO DI ROTAZIONE DEI MOTORI” E

RIPETERE LA PROGRAMMAZIONE SCELTA.

E - PROGRAMMAZIONE CODICI RADIO APERTURA TOTALE

(62 CODICI MAX - SOLO MODELLI CRX)

La programmazione può essere eseguita solo a cancello fermo.

1 - Posizionare DIP 1 su ON e successivamente il DIP 2 su ON.

2 - Il led rosso DL1 di programmazione lampeggia con frequenza di 1 sec. ON e 1 sec. OFF

I

I

per 10 secondi.

3 - Premere il tasto del telecomando (normalmente il canale A) entro i 10 secondi impostati.

Se il telecomando viene correttamente memorizzato il led DL10 (verde) emette un lampeggio.

4 - Il tempo di programmazione dei codici si rinnova automaticamente per poter memorizzare il telecomando successivo.

5 - Per terminare la programmazione lasciare trascorrere 10 sec., oppure premere per un attimo il pulsante PROG. Il led rosso DL1 di programmazione smette di lampeggiare.

6 - Riposizionare DIP 1 su OFF e DIP 2 su OFF.

7 - Fine procedura.

PROCEDURA CANCELLAZIONE DI TUTTI I CODICI RADIO DEDICATI ALL’APERTURA

TOTALE

La cancellazione può essere eseguita solo a cancello fermo.

1 - Posizionare il DIP 1 su ON e successivamente il DIP 2 su ON.

2 - Il led rosso DL1 di programmazione lampeggia con frequenza di 1 sec. ON e 1 sec. OFF per 10 secondi.

3 - Premere e mantenere premuto il pulsante PROG per 5 secondi. La cancellazione della memoria viene segnalata da due lampeggi del led verde DL10.

4 - Il led rosso DL1 di programmazione rimane attivo ed è possibile inserire nuovi codici come da procedure sopra descritte.

5 - Riposizionare DIP 1 su OFF e DIP 2 su OFF.

6 - Fine procedura.

SEGNALAZIONE MEMORIA SATURA CODICI RADIO DEDICATI ALL’APERTURA TOTALE

La segnalazione si può ottenere solo a cancello fermo.

1 - Posizionare il DIP 1 su ON e successivamente il DIP 2 su ON.

2 - Il led verde DL10 lampeggia per 6 volte segnalando memoria satura (62 codici presenti).

Successivamente il led DL1 di programmazione rimane attivo per 10 secondi, consentendo un eventuale cancellazione totale dei codici.

4 - Riposizionare DIP 1 su OFF e DIP 2 su OFF.

5 - Fine procedura.

PULSANTE DI COMANDO PASSO-PASSO (COM-K BUTTON)

Se DIP 6 su OFF => Esegue un comando ciclico dei comandi apre-stop-chiude-stop-apre ecc.

Se DIP 6 su ON => Esegue l’apertura a cancello chiuso. Se azionato durante il movimento di apertura non ha effetto. Se azionato a cancello aperto lo chiude e durante la chiusura se azionato lo fa riaprire.

PULSANTE DI APERTURA (COM-OPEN)

A cancello fermo il pulsante comanda il moto di apertura. Se viene azionato durante la chiusura fa riaprire il cancello.

FUNZIONE OROLOGIO DEL PULSANTE DI APERTURA

Se desiderate applicare un orologio (o più semplicemente un’interruttore) per aprire e mantenere aperto il cancello, dovete richiedere T2 24V con fw 03 NOUP.

Se fw 03 o superiore ATTENZIONE: IN CASO DI GUASTO ALLE SICUREZZE, UN

MINUTO DOPO CHE L’OROLOGIO O L’INTERRUTTORE SONO STATI ATTIVATI, IL

CANCELLO SI APRIRA’ SENZA SICUREZZE ATTIVE !

La funzione orologio è utile nelle ore di punta, quando il traffico veicolare risulta rallentato

(es. entrata/uscita operai, emergenze in zone residenziali o parcheggi e, temporaneamente, per traslochi).

F - PROGRAMMAZIONE CODICI RADIO APERTURA PEDONALE

(62 CODICI MAX - SOLO MODELLI CRX)

La programmazione può essere eseguita solo a cancello fermo.

1 - Posizionare DIP 1 su ON e successivamente il DIP 3 su ON.

2 - Il led rosso DL1 di programmazione lampeggia con frequenza di 1 sec. ON e 1 sec. OFF per 10 secondi.

3 - Premere il tasto del telecomando (normalmente il canale B) entro i 10 secondi impostati.

Se il telecomando viene correttamente memorizzato il led DL10 (verde) emette un lampeggio.

4 - Il tempo di programmazione dei codici si rinnova automaticamente per poter memorizzare il telecomando successivo.

5 - Per terminare la programmazione lasciare trascorrere 10 sec., oppure premere per un attimo il pulsante PROG. Il led rosso DL1 di programmazione smette di lampeggiare.

6 - Riposizionare DIP 1 su OFF e DIP 3 su OFF.

NOTA: SE IL LED DL1 CONTINUA A LAMPEGGIARE VELOCEMENTE, SIGNIFICA CHE

IL DIP 1 RISULTA ANCORA POSIZIONATO IN ON E QUALSIASI MANOVRA VIENE

NEGATA.

7 - Fine procedura.

PROCEDURA CANCELLAZIONE DI TUTTI I CODICI RADIO DEDICATI ALL’APERTURA

PEDONALE

La cancellazione può essere eseguita solo a cancello fermo.

1 - Posizionare il DIP 1 su ON e successivamente il DIP 3 su ON.

2 - Il led rosso DL1 di programmazione lampeggia con frequenza di 1 sec. ON e 1 sec. OFF per 10 secondi.

3 - Premere e mantenere premuto il pulsante PROG per 5 secondi. La cancellazione della memoria viene segnalata da due lampeggi del led verde DL10.

4 - Il led rosso DL1 di programmazione rimane attivo ed è possibile inserire nuovi codici come da procedure sopra descritte.

5 - Riposizionare DIP 1 su OFF e DIP 3 su OFF.

6 - Fine procedura.

SEGNALAZIONE MEMORIA SATURA CODICI RADIO DEDICATI ALL’APERTURA PEDONALE

La segnalazione si può ottenere solo a cancello fermo.

1 - Posizionare il DIP 1 su ON e successivamente il DIP 3 su ON.

2 - Il led verde DL10 lampeggia per 6 volte segnalando memoria satura (62 codici presenti).

3 - consentendo un eventuale cancellazione totale dei codici.

4 - Riposizionare DIP 1 su OFF e DIP 3 su OFF.

5 - Fine procedura.

MODALITÁ DI APPLICAZIONE FUNZIONE OROLOGIO

Richiedere T2 24V con firmware 02.

Collegando un interruttore e/o un orologio di tipo giornaliero/settimanale (al posto o in parallelo al pulsante di apertura N.O. “COM-OPEN”), è possibile aprire e mantenere aperta l’automazione finché l’interruttore viene premuto o l’orologio rimane attivo.

Ad automazione aperta vengono inibite tutte le funzioni di comando.

Rilasciando l’interruttore, o allo scadere dell’ora impostata, si avrà la chiusura immediata dell’automazione.

PULSANTE DI CHIUSURA (COM-CLOSE)

A cancello fermo comanda il moto di chiusura.

TELECOMANDO

Se DIP 6 su OFF => Esegue un comando ciclico dei comandi apre-stop-chiude-stop-apreecc.

Se DIP 6 su ON => Esegue l’apertura a cancello chiuso. Se azionato durante il movimento di apertura non ha effetto. Se azionato con cancello aperto, lo chiude. Se azionato durante il movimento di chiusura lo fa riaprire.

PULSANTE APERTURA PEDONALE (COM-PED.BUTT.)

Comando dedicato ad un’apertura parziale e alla sua richiusura.

Durante l’apertura, la pausa o la chiusura pedonale, è possibile comandare l’apertura da qualsiasi comando collegato sulla scheda T2 24V.

Tramite DIP 6 è possibile scegliere la modalità di funzionamento del pulsante di comando pedonale.

Se DIP 6 su OFF => Esegue un comando ciclico dei comandi apre stop-chiude-stop ecc.

Se DIP 6 su ON => Esegue l’apertura a cancello chiuso. Se azionato durante il movimento di apertura non ha effetto. Se azionato a cancello aperto lo chiude e durante la chiusura, se azionato, lo fa riaprire.

SERRATURA ELETTRICA (LOCK)

Mettere il DIP 8 su ON per abilitare il comando della serratura elettrica in apertura.

COLPO DI SGANCIO SERRATURA ELETTRICA IN APERTURA

Mettere il DIP 9 su ON per abilitare il colpo di sgancio della serratura elettrica in apertura (a condizione che DIP 8 sia su ON).

A cancello chiuso, se si preme un comando di apertura, il cancello per 0,5s esegue la manovra di chiusura e contemporaneamente viene attivata la serratura elettrica (seguita da

0,5s di pausa e quindi dall’apertura del cancello).

COLPO DI AGGANCIO SERRATURA ELETTRICA

Mettere il DIP 10 su ON per abilitare il colpo di aggancio della serratura elettrica in chiusura.

A chiusura avvenuta vengono comandati per 0,5s i motori a piena tensione per garantire l’aggancio della serratura.

FUNZIONAMENTO ACCESSORI DI COMANDO

FACILITAZIONE SBLOCCO MOTORI

Mettere il DIP 11 su ON per abilitare la facilitazione sblocco manuale (a condizione che il DIP

10 sia su ON), a chiusura avvenuta verrà eseguita una manovra di inversione con un tempo fisso di 0,2s per facilitare lo sblocco manuale.

ATTENZIONE: COLLEGARE ACCESSORI DI COMANDO SOLO SE IMPULSIVI.

Assicurarsi che eventuali altri tipi di accessori di comando (per esempio sensori magnetici) siano programmati nella modalità IMPULSIVA, altrimenti attiverebbero la movimentazione del cancello senza sicurezze attive.

FUNZIONAMENTO ACCESSORI DI SICUREZZA

12

FOTOCELLULA (COM-PHOT)

DIP 4 OFF => A cancello chiuso se un ostacolo è davanti al raggio delle fotocellule, il

cancello non apre. Durante il funzionamento le fotocellule intervengono sia in apertura (con ripristino del moto in apertura solo dopo la liberazione del raggio delle fotocellule), che in chiusura (con ripristino del moto inverso solo dopo la liberazione del raggio delle fotocellule).

DIP 4 ON => A cancello chiuso se un ostacolo è davanti al raggio delle fotocellule e viene comandata l’apertura, il cancello apre (durante l’apertura le fotocellule non interverranno).

Le fotocellule interverranno solo in fase di chiusura (con ripristino del moto inverso dopo un secondo anche se le stesse restano impegnate).

GESTIONE CHIUSURA IMMEDIATA DOPO IL TRANSITO DA FOTOCELLULE

DIP 16 ON e DIP 4 OFF => Mentre il cancello apre, transitando davanti alle fotocellule il cancello si ferma. Completato il transito, dopo 1 secondo il cancello chiude.

DIP 16 ON e DIP 4 ON => Mentre il cancello apre, transitando davanti alle fotocellule il cancello continua ad aprire. Completato il transito, il cancello si ferma e dopo 1 secondo di pausa inverte il moto in chiusura.

Se si raggiunge la completa apertura (fine tempo di apertura), la chiusura immediata viene esclusa e viene attivato il tempo di chiusura automatica (se trimmer TCA abilitato e led DL6 acceso). Se durante la chiusura si ha un transito veloce (es. pedone) il cancello riaprirà per due secondi per poi richiudere nuovamente.

DIP 12 OFF => chiusura immediata dopo il transito dalle fotocellule disabilitata.

N.B.: Si raccomanda di verificare la funzionalità delle fotocellule almeno ogni 6 mesi.

il loro funzionamento non è consentito dalle norme.

Al ripristino del contatto delle sicurezze, dopo 1 secondo, viene automaticamente riabilitato il funzionamento automatico o passo passo e quindi anche il radiocomando e la chiusura automatica riprendono a funzionare.

Nota 1: durante questo funzionamento in caso di guasto alle coste (oppure fotocellule) le fotocellule (oppure coste) funzionano ancora interrompendo la manovra in atto.

Nota 2: il pulsante di stop non è considerato una sicurezza da bypassare in questa modalità, pertanto se viene premuto o è rotto, non consente alcuna manovra.

La manovra a uomo presente è esclusivamente una manovra di emergenza che deve essere effettuata per brevi periodi e con la sicurezza visiva del movimento dell’automatismo. Appena possibile le protezioni guaste devono essere ripristinate per un corretto funzionamento.

LAMPEGGIATORE

N.B.: Questo quadro elettronico può alimentare SOLO LAMPEGGIATORI CON CIRCUITO

LAMPEGGIANTE (ACG7061) con lampade da 24V e 20W massimo.

FUNZIONE PRE-LAMPEGGIO

DIP 5 - OFF => il motore e il lampeggiatore partono contemporaneamente.

DIP 5 - ON => il lampeggiatore parte 3 secondi prima del motore.

EDGE (COSTA) (COM-EDGE)

Durante l’apertura, se impegnata, inverte il moto in chiusura.

Durante la chiusura, se impegnata, inverte il moto in apertura.

Se rimane impegnata dopo il primo impegno, esegue un’ulteriore inversione dopo 2 secondi, per poi eseguire un’ulteriore piccola inversione e quindi segnalare l’allarme di costa guasta o impegnata (contatto NO).

Se la costa rimane impegnata (contatto NO) nessuna movimentazione è consentita.

Se non usata, ponticellare i morsetti COM-EDGE.

MONITORAGGIO COSTE DI SICUREZZA (A+TEST A-)

Tramite l’ingresso A+TEST ed il DIP 12 ON è possibile monitorare la/le costa/e.

Il monitoraggio consiste in un Test Funzionale, della costa, eseguito al termine di ogni completa apertura del cancello.

Dopo ogni apertura, la chiusura del cancello viene pertanto consentita solo se la/le costa/e hanno superato il Test Funzionale.

ATTENZIONE: IL MONITORAGGIO DELL’INGRESSO COSTA PUÒ ESSERE ABILITATO CON IL

DIP 12 IN ON, OPPURE DISABILITATO CON IL DIP 12 IN OFF. INFATTI, IL TEST FUNZIONALE

DELLE COSTE E’ POSSIBILE SOLO NEL CASO SI TRATTI DI DISPOSITIVI DOTATI DI UN

PROPRIO ALIMENTATORE DI CONTROLLO.

UNA COSTA MECCANICA NON PUO’ ESSERE MONITORATA, PERTANTO IL DIP 12 DEVE

ESSERE POSIZIONATO IN OFF.

SPIA DI SEGNALAZIONE CANCELLO APERTO (COM-SIGNAL)

Ha il compito di segnalare gli stati di cancello aperto, parzialmente aperto o comunque non chiuso totalmente. Solo a cancello completamente chiuso si spegne.

Durante la programmazione questa segnalazione é attiva.

N.B.: Max 3 W. Se si eccede con le pulsantiere o con le lampade, la logica del quadro elettronico ne risulterà compromessa con possibile blocco delle operazioni.

FUNZIONAMENTO DOPO BLACK-OUT (SENZA BATTERIE)

Al ritorno della tensione di rete il led DL1 si accende e rimane acceso per tutto il tempo in cui il cancello rimane aperto. Si spegnerà al raggiungimento della chiusura totale del cancello.

Si consiglia di far aprire completamente il cancello. Lasciate che il cancello si chiuda da solo con la chiusura automatica o attendete che il lampeggiatore finisca di lampeggiare prima di comandare la chiusura.

Questa operazione consentirà al cancello di riallinearsi. Infatti, se durante il black-out i motori sono stati sbloccati e spostati dalla normale posizione di chiusura, la prima manovra al ritorno dell’alimentazione deve essere completa.

Se il black-out avviene durante il movimento, o a cancello aperto, e il primo comando risulta essere quello di chiusura, la chiusura avverrà con sfasamento totale delle ante pertanto prima chiuderà M2 e allo spegnimento di M2 chiuderà M1. Questo movimento separato dei due motori eviterà l’accavallamento delle ante.

PULSANTE DI STOP (COM-STOP)

Durante qualunque operazione il pulsante di STOP esegue il fermo del cancello.

Se premuto a cancello aperto totalmente (o parzialmente utilizzando il comando pedonale) si esclude temporaneamente la chiusura automatica (se abilitata tramite trimmer TCA e led DL6 acceso). E quindi necessario dare un nuovo comando per farlo richiudere.

Al ciclo successivo la funzione chiusura automatica viene riattivata (se abilitata tramite trimmer TCA e led DL6 acceso).

ALLARME DA SENSORE DI CORRENTE

La centrale T2 24V è dotata di sensori automatici che fanno invertire la marcia del cancello nel caso di impatti contro cose o persone in conformità alle norme EN vigenti (verificare sempre con apposito strumento il rispetto dei valori imposti dalla norma), senza dover effettuare particolari regolazioni sulla centrale, in quanto gestiti da uno speciale software interno.

Se dopo un primo intervento del sensore di corrente in apertura o chiusura (solo ad alta velocità) se ne ha un secondo, ovviamente nel senso contrario, il cancello si ferma e quindi inverte per 1 secondo.

Lo stato di allarme verrà visualizzato dal lampeggiatore che rimarrà attivo per un minuto, durante questo tempo è possibile ristabilire il funzionamento del cancello premendo un qualsiasi pulsante di comando.

CARATTERISTICHE TECNICHE

ALLARME DA AUTOTEST COSTA (DIP 12 ON)

A fine apertura se il monitoraggio della costa ha esito negativo, subentra un allarme visualizzato dal lampeggiatore che rimane acceso, in questa condizione la chiusura del cancello non viene consentita, solo riparando la costa e premendo uno dei comandi abilitati e’ possibile ripristinare la normale funzionalità.

FUNZIONAMENTO AD UOMO PRESENTE IN CASO DI GUASTO DELLE SICUREZZE

Se la costa è guasta o impegnata per più di 5 secondi, o se la fotocellula è guasta o impegnata per più di 60 secondi, i comandi APRE, CHIUDE, K BUTTON E PEDONALE funzioneranno solo ad uomo presente.

La segnalazione dell’attivazione di questo funzionamento è data dal led di programmazione che lampeggia.

Con questo funzionamento viene consentita l’apertura o la chiusura solo mantenendo premuti i pulsanti di comando. Il comando radio e la chiusura automatica vengono esclusi in quanto

13

- Range di temperatura

- Umidita

- Tensione di alimentazione

- Frequenza

- Alimentazione batteria

- Potenza Trasformatore

0 ÷ 55°C

< 95% senza condensazione

230V~ ±10% (120V/60Hz a richiesta)

50/60 Hz

20-24VDC

130VA primario 230Vac secondario 18Vac

- Assorbimento massimo

- Microinterruzioni di rete

50 mA

100ms

- Potenza massima spia cancello aperto 24Vdc 3W (equivalente a 1 lampadina da 3W o

5 led con resistenza in serie da 2,2 k ohm)

- Carico massimo lampeggiatore 24Vdc 20W

- Corrente disponibile per fotocellule e accessori 1A ±15%

- Corrente disponibile su connettore radio 200mA

CARATTERISTICHE TECNICHE RADIO (modello T2 24V crx)

- Frequenza Ricezione

- Impedenza

- Sensibilità

- Tempo eccitazione

433,92MHz

52 OHM

>2,24µV

300ms

- Tempo diseccitazione 300ms

- Tutti gli ingressi devono essere utilizzati come contatti puliti perchè l’alimentazione è generata internamente (tensione sicura) alla scheda ed è disposta in modo da garantire il rispetto di isolamento doppio o rinforzato rispetto alle parti a tensione pericolosa.

- Eventuali circuiti esterni collegati alle uscite del quadro elettronico, devono essere eseguiti per garantire l’isolamento doppio o rinforzato rispetto alle parti a tensione pericolosa.

- Tutti gli ingressi vengono gestiti da un circuito integrato programmato che esegue un autocontrollo ad ogni avvio di marcia.

I

I

RISOLUZIONE PROBLEMI

Dopo aver effettuato tutti i collegamenti seguendo attentamente lo schema ed aver posizionato il cancello in posizione intermedia, verificare la corretta accensione dei led rossi DL7, DL8 e DL9.

In caso di mancata accensione dei led, sempre con cancello in posizione intermedia, verificare quanto segue e sostituire eventuali componenti guasti.

DL7 spento Fotocellule guaste

DL8 spento Costa sicurezza guasta (In caso la costa non sia collegata, eseguire il ponticello fra Com e Edge)

DL9 spento Pulsante di Stop guasto (In caso lo Stop non sia collegato, eseguire il ponticello fra Com e Stop).

Durante il funzionamento a uomo presente, con DIP n° 1 in ON, verificare che durante l’apertura di M1 e M2 si accendano i led verdi DL2 e DL4 e che durante la chiusura di M1 e M2 si accendano i led rossi DL3 e DL5.

In caso contrario, invertire i fili del motore interessato.

DIFETTO

Dopo aver effettuato i vari collegamenti e aver dato tensione, tutti i led sono spenti.

SOLUZIONE

Verificare l’integrità dei fusibili F1, FUSE 1.

In caso di fusibile interrotto usarne solo di valore adeguato.

F1 T 2A FUSIBILE DI PROTEZIONE TRASFORMATORE (esterno alla scheda T2 24V)

FUSE 1 8A FUSIBILE DI PROTEZIONE MOTORI

Il motore apre e chiude, ma non ha forza e si muove lentamente.

Il cancello esegue l’apertura, ma non chiude dopo il tempo impostato.

Verificare regolazione trimmer RUN e LOW-SPEED.

Accertarsi che il trimmer TCA sia abilitato con led DL6 acceso.

Pulsante OPEN sempre inserito, sostituire pulsante o switch del comando OPEN.

Autotest costa fallito, verificare i collegamenti tra quadro elettronico e alimentatore per coste. Attenzione: se non si sta utilizzando un alimentatore per coste il dip 12 deve essere posizionato in OFF.

Il cancello non apre e non chiude azionando i vari pulsanti K, Radio, Open e Close.

La serratura elettrica non funziona.

Contatto costa sicurezza guasto. Contatto fotocellule guasto con DIP 4 OFF.

Sistemare o sostituire il relativo contatto.

Accertarsi di avere abilitato il DIP 8 in ON.

Il led DL1 lampeggia velocemente e nessuna movimentazione è abilitata.

Posizionare i dip switch 1, 2 o 3 in posizione OFF.

OPTIONAL -

Per i collegamenti ed i dati tecnici degli accessori attenersi ai relativi libretti di istruzione.

SCHEDA DI CARICA BATTERIA

CHIAVISTELLO MECCANICO

BATTERIA

Batteria 2,2Ah 12V cod. ACG4648 Chiavistello meccanico per cancelli a due ante.

SERRATURA ELETTRICA

cod. ACG5000 cod. ACG9515

14

Serratura Orizzontale - destra vista esterna - 12Vac

Serratura Orizzontale - sinistra vista esterna - 12Vac

Serratura Verticale - 12Vac cod. ACG8660 cod. ACG8670 cod. ACG8650

T2 24V Wi-Fi

Quadro con sensori di impatto e scheda MASTER Wi-Fi.

Con contenitore. cod. ABT2025W

DISPOSITIVI Wi-Fi

MASTER Wi-Fi

SCHEDA DI GESTIONE SISTEMA SENZA FILI con innesto - 12÷30V ac/dc con morsettiera - 12÷30V ac/dc

NOVA Wi-Fi

cod. ACG6094 cod. ACG6099

VERTIGO Wi-Fi

FOTOCELLULE SENZA FILI

COPPIA COLONNINE NOVA

BLOCK Wi-Fi

cod. ACG8037 cod. ACG8039

FOTOCELLULE SENZA FILI SOSTITUTIVE DELLA COSTA

VERTIGO Wi-Fi 8 cod. ACG8042 - VERTIGO Wi-Fi 10 cod. ACG8043

SPARK Wi-Fi

SELETTORE A CHIAVE SENZA FILI cod. ACG7064 cod. ACG7042 cod. ACG6098

15

LAMPEGGIATORE SENZA FILI

SUPPORTO LATERALE

I

F

SCHÉMA DÉTAILLÉ DE L’INSTALLATION

2

5 1

1 - Opérateur PRINCE

2 - Antenne radio

3 - Signal electrique

4 - Selecteur

5 - Photocellules p/protection externe

5 4

4

1

CARACTERISTIQUES TECHNIQUES

PRINCE est un opérateur utilisé pour manoeuvrer des portails à battans jusqu’à

3 m de longeur et 250 kg de poids (Fig.1).

Les opérateurs PRINCE utilisent les fin de course mécaniques intégrés, de ce fait évitant le devoir installer des fins de course électriques.

N.B.: Il sera nécessaire de monter une serrure électrique pour assurer une fermeture efficace.

CARACTERISTIQUES TECHNIQUES

Longueur maxi du battant

Poids maxi du battant

Course maxi d’entrainement

Temps moyen d’ouverture

Vitesse de traction

Alimentation et frequence

Puissance moteur (vis a 71 rpm)

Puissance moteur bloqué

Absorption nominale

Absorption moteur bloqué

Force nominal de poussée

Force de poussée moteur bloqué

Cycles normatifs

Cycles conseillés par jour

Service

Cycles consécutifs garantis

Poids du moteur

Bruit

Temperature de travail

Indìce de protection m kg mm s.

m/s

PREMIER 24V

3

250

343**

14

0,0134

24Vdc

12 W

W

A

A

N

N n° n°

% n° kg db

°C

IP

89

0,88

3,72

1000

1500

∞ - 14s/2s

60

80

60/14s

5

<70

-30 ÷ +55°C

44

** Avec une butée mécanique incorporée qui intervient pendant l’ouverture. Si l’on utilise aussi la butée mécanique qui intervient pendant la fermeture, en option, la course maximale d’entraînement s’écourte de 30 mm.

Mesures en mm

2

16

INSTALLATION PRINCE

CONTROLE PRE-INSTALLATION

Le portail à battant doit être solidement fixé aux poteaux, ne doit pas flechir pendant le mouvement et doit pouvoir manoeuvrer sans effort.

Avant d’installer PRINCE, il convient de verifier tous les encombrements necessaires pour proceder à l’installation.

Si le portail se presente comme indiqué Fig. 1, aucune modification n’est necessaire.

N.B. Il est impératif d’uniformiser les caractéristiques du portail avec les normes et les lois en vigueur. La porte peut être automatisée seulement si elle est en bon état et qu’elle est conforme à la norme EN 12604.

- Le vantail ne doit pas comporter de portillon intégré. Dans le cas contraire, il sera opportun de prendre les précautions décrites au point 5.4.1 de la EN 12453 (interdire, par le biais d’un contact raccordé aux bornes adaptées de la platine électronique, la mise en marche de l’automatisme si le portillon est ouvert).

- Ne pas générer de zone d’écrasement (par exemple entre le vantail ouvert et la cloture).

Parties à installer conformément à la norme EN12453

TYPE DE COMMANDE

Personne expertes

(au dehors d’une zone publique*)

A

USAGE DE LA FERMETURE

Personne expertes

(zone publique)

B

Usage illimité non possible homme presente impulsion en vue

(es. capteur) impulsion hors de vue

(es. boîtier de commande) automatique

C ou E

C ou E

C ou E

C et D, ou E

C et D, ou E

C et D, ou E

C et D, ou E C et D, ou E C et D, ou E

* example typique: fermetures qui n’ont pas d’accès à un chemin public

A: Touche de commande à homme present (à action maintenue), code ACG2013.

B: Sélecteur à clef à homme mort, code ACG1010.

C: Réglage de la puissance du moteur.

D: Barre palpeuse et/ou autres dispositifs de limitation des forces dans les limites de la norme EN12453- appendice A.

E: Cellules photo-électriques, code ACG8026 (Appliquer chaque 60÷70 cm pour toute la taille de la colonne de la porte jusqu’à un maximum de 2,5 m - EN 12445 point 7.3.2.1).

MANOEUVRE DE SECOURS

Pour actionner le portail manuellement il est necessaire introduire la clé appropriée dans la serrure et la tourner de 90° dans le sense anti-horaire (Fig. 3).

Afin de pouvoir manœuvre manuellement le vantail, il est important de vérifier que :

- Il soit fourni des poignées adaptées sur le vantail

- Ces poignées doivent être positionnées de sorte à ne pas créer un danger durant leur utilisation.

- L’effort manuel pour mettre en mouvement le vantail ne doit pas excéder 225N pour les portes et portails en usage privé, et 390N pour les portes et portails à usage industriel et commercial (valeurs indiquées au paragraphe 5.3.5 de la norme EN 12453).

FIXATION DE L’ATTACHE DU MOTEUR A LA COLONNE

Lors de l’installation du PRINCE, il est necessaire de respecter certaines mesures afin d’obtenir un mouvement correct du vantail (Fig. 4, 5, 7, 8, 9).

Si le poteau est en fer, il est possible de visser directement l’attache au moyen de vis filetée

M8.

si le poteau est en ciment fixer l’attache au moyen de 4 chevilles de Ø 8 mm.

En cas de mur parallèle au portail lorsque celui-ci est ouvert il est necessaire de pratiquer une niche pour loger le motoreducteur.

FIXATION DE L’ATTACHE DU MOTEUR AUX PORTAILS

Ensuite poursuivre l’installation en vissant sur le vantail la fixation pour le dispositif d’entrainement du portail, en respectant les mesures prevues (Fig. 6, 9).

Installer PRINCE en essayant plusieurs fois d’ouvrir et de fermer en controlant que le profile cache-vis ne frotte pas lorsque le portail est en mouvement.

17

3

4

5

graisser soigneusement

6

OUI !

Assurez-vous de serrer la vis qui maintient le support de l’opérateur afin qu’il puisse tourner librement.

7

NON !

L’opérateur ne doit pas varier sa hauteur pendant le mouvement.

8

F

F

S1

Z

Y

X

Se conformer à la mesure et faire en sorte que l’opérateur est horizontale

S2

Z

Y

X

COL

Attache poteau

Z

Y

X

S3

Mesures à respecter pour une correcte installation

L

Min.÷Max

1÷3 a

A max

B C D E

T sec

COL ANT

90°

0 100 100 765 90 13,5 S2-X A

20 100 100 765 90 13,5

S2-Y A

40 100 100 765 90 13,5 S3-X A

60 110 100 765 90 14 S3-Y A

80 140 110 765 115 17 S3-X B

100 160 110 765 115 18

S3-X B

120 180 110 765 115 19,5 S3-X B

140 210 110 765 115 21,5 S1-Z B

150 220 120 765 115 23 S1-Z B

110°

20 110 140 765 90 17

S1-Y A

Mesures de respecter AVEC DEUX ARRETS MECANIQUES

L

Min.÷Max

1÷3 a

A max

B C D E

T sec

COL ANT

0 100 100 730 90 13,5 S2-X A

20 100 100 730 90 13,5

S2-X A

40 100 100 730 90 13,5 S3-X A

60 110 100 730 90 14 S3-X A

90°

80 140 110 730 115 17 S3-X B

100 160 110 730 115 18

S3-X B

110 180 120 730 115 20 S1-Z B

110°

20 100 140 730 90 16 S2-Y A

ANT

Attache vantail

A

B

Si le pilier est très large et qu’il n’est pas possible d’installer le motoréducteur en respectant la mesure (B), il faut realiser une niche dans le pilier ou deplacer le portail sur l’arête interne du pilier.

9

18

ARRÊT MÉCANIQUE - OPTION

(Cod. ACG8088)

Arrêt mécanique en OPTION pour arrêter la fermeture si le portail n’est pas pourvu de dispositif d’arrêt au sol.

REGLAGE FINS DE COURSE MECANIQUES

Pour positionner les colliers, il est necessaire agir selon les indications du schema (Fig. 11).

Pour obtenir l’ouverture desirée, il suffit de déplacer le collier (A) et de le bloquer en vissant la vis M8 avec une clé n°13.

Pour obtenir la fermeture desirée, il est necessarie de deplacer le collier (B) (OPTIONAL) et de le bloquer comme indiqué ci-dessus.

ENTRETIEN

Effectuer seulement par personnel specialisé après avoir coupé l’alimentation.

Tous les ans, graisser les gonds et contrôler la force de poussée exercée par le motoréducteur sur le portail.

Tous les deux ans, il est conseillé de lubrifier la vis-mère avec une graisse à base de silicone.

BRANCHEMENTS ÉLECTRIQUES

A B

C

19

D

10

11

F

F

T2 24V code AC07088

T2 24V CRX code AC07089

ANTENNE

COMMUN

FERMETURE

OUVERTURE

STOP

ENVELOPPE

ANTENNE

24Vdc 0,8A ± 15% pour ACCESSOIRES

24Vdc 0,8A ± 15% AUTOTEST pour

BARRE PALPEUSE

FEU CLIGNOTANT

24Vdc 20W

LED

PIETON

PAS A PAS

PHOTOCELLULES

COMMUN

BARRE PALPEUSE

R=2,2K 1/4W

SERRURE

ÉLECTRIQUE

ALIMENTATION

230Vac 50Hz

Fusible

T 2 A

TRANSFORMATEUR

M1

M2

20

J5

J6

J7

J1

J2

J3

J4

J8

J9

J10

TR1

TR2

TR3

N F

COM.

CLOSE

OPEN

STOP

AERIAL

SIGNAL

Alimentation 230Vac 50/60Hz - externe à la fiche -

(120V/60Hz sur demande)

Commun des contacts

Contatto impulso de fermeture (NA)

Contatto impulso d’ouverture (NA)

Contact impulsion de stop (NC)

Antenne radio

Voyant portail ouvert et signalisation état de fonctionnement avec batterie et batterie déchargée (24Vdc 3W max)

Positif pour alimentation autotest barre palpeuse A+TEST

EDGE N.C.

COM.

PHOTO N.C.

K BUTT.

PED. BUTT.

A+

A -

LOCK

Contact barre palpeuse de sécurité (NC)

Commun des contacts

Contact photocellules (NC)

Contact impulsion simple (NA)

Contact commande ouverture piétonne (NA)

Positif pour alimentation accessoires à 24Vdc

Négatif pour alimentation accessoires à 24 Vdc

Connexion électro-serrure (MAX 15W 12V)

Connexion phase négative clignotant à 24Vdc (code

ACG7061). Attention aux polarités.

Connecteur pour transformateur secondaire 18 Vac SECONDARY

TRANSFORMER

MOTOR 1 Connexion MOTEUR 1 (sans polarité)

MOTOR 2 Connexion MOTEUR 2 (sans polarité)

Connecteur dédié à la programmation en usine. NE PAS

TOUCHER AU CAVALIER! SANS L’OPÉRATEUR, IL NE

FONCTIONNE PAS!

SW T2 24V

Connecteur dédié à la programmation en usine. (seulement pour les modèles CRX) NE PAS TOUCHER AU CAVALIER! SI

LE SYSTÈME RADIO EST ENLEVÉ, IL NE FONCTIONNE PAS!

SW RADIO

RADIO

BATTERY

CHARGER

Module radio incorporé (modèle CRX), ou connecteur pour radio récepteur RIB à enclenchement avec alimentation à

24Vdc

Connecteur pour fiche de recharge batterie à 24Vdc (code

ACG4648)

TRIMMER RUN Trimmer de réglage de la grande vitesse

TRIMMER LOW

SPEED

Trimmer de réglage de la basse vitesse

TRIMMER TCA Trimmer de régulation du temps d’attendue avant avoir la fermeture automatique (DÉFAUT DÉSHABILITÉ ET LED DL6

ÉTEINT)

A - BRANCHEMENTS

J9

J10

J8

J7

S3

S3 PROG

FUSE 1 T 8 A

F1 T 2 A

J2 J3

J1

TR1

Bouton pour la programmation

Fusible de protection moteur

Fusible de protection transformateur

TR2

B - RÉGLAGES

DIP 1 (ON) - COMMANDE SENS DE ROTATION DU MOTEUR (POINT C)

DIP 2 (ON) - PROGRAMMATION DES TEMPS (POINT D)

(ON) - ACTIVATION POUR LE RELACHEMENT DES PORTES PENDANT

LES PHASES DE RALLENTISSEMENT, D’OUVERTURE ET DE FERMETURE

COMPLETE (PAR RAPPORT AUX TESTS D’IMPACT SELON LA NORME

EN12453)

MEMORISATION/ANNULATION DES CODES RADIO POUR COMMANDE

OUVERTURE COMPLETE (UNIQUEMENT POUR LE MODELE CRX) (POINT E)

MEMORISATION/ANNULATION DES CODES RADIO POUR COMMANDE

OUVERTURE COMPLETE (UNIQUEMENT POUR LEMODELE CRX) (POINT F)

DIP 2-1 PROGRAMMATION DES TEMPS D’OUVERTURE PIETONNE AVEC MICRO-

INTERRUPTEURS DE GESTION

DIP 4 Photocellules toujours actives (OFF) - Photocellules actives uniquement à la fermeture (ON)

DIP 5 Pré-clignotement (ON) - Clignotement normal (OFF)

DIP 6 Commande mono-impulsion (K BUTT) et récepteur radio pas-à-pas (OFF) - automatique (ON)

DIP 7 fonctionnement avec capteur de courant (ON-activé) Fonctionnement préprogrammé (OFF-activé)

DIP 8 Habilitation de la serrure électrique (ON-activé)

DIP 9 Habilitation coup de désenclenchement de la serrure électrique (ON - activé)

DIP 10 Habilitation coup d’enclenchement de la serrure électrique (ON -activé)

DIP 11 Habilitation du déblocage assisté (ON-activé)

F1

TRANSFORMER

J4

FUSE 1

J5

J6

TR3

DIP 12 Habilitation du TEST de monitorage de la tranche de sécurité

DIP 13 Sélection fonctionnement à 1 ou 2 moteurs (par défaut OFF 2 moteurs)

DIP 14 OFF

DIP 15 OFF

DIP 16 FERMETURE IMMEDIATE APRES PASSAGE DEVANT LES PHOTOCELLULES

ON ACTIVEE

DESACTIVEE OFF

JP1 => Vérifier que le cavalier est bien inséré!

JP2 => Vérifier que le cavalier est bien inséré!

JP3 => Vérifier que le cavalier est bien inséré!

PROG => S3 Bouton pour la programmation

REGLAGES

ATTENTION: POSITIONNER LE DIP 3 SUR ON SEULEMENT APRES AVOIR EFFECTUE

TOUTES LES PROGRAMMATIONS.

REMARQUE: AVEC DIP 3 (en position ON), LA FONCTION D’INVERSION RAPIDE DES

PORTES APRES IMPACT S’ACTIVE.

CETTE INVERSION RAPIDE DES PORTES PERMET D’ANNULER LA FORCE STATIQUE

AVANT LES 5 SECONDES INDIQUEES PAR LA NORME EN12453 ANNEXE A CHAP.

2.2 (FORCES STATIQUES ADMISSIBLES) RESPECTANT AINSI LES TESTS D’IMPACT

INDIQUES EGALEMENT PAR LADITE NORME.

DANS LE CAS OU VOUS NE POURRIEZ PAS RESPECTER LES PRESCRIPTIONS DE

LA NORME 12453, POSITIONNER LE DIP 3 SUR OFF. DANS CE CAS LES PORTES

S’ARRETERONT SANS INVERSER LE MOUVEMENT.

21

F

F

TRIMMER RUN (TR1) Régulateur électronique de vitesse

Avec ce trimmer il est possible de régler la vitesse du moteur (par défaut il est positionné sur la vitesse maximale). Le réglage est très utile pour rendre l’automatisme conforme aux normes européennes en matière d’impacts.

TRIMMER LOW SPEED (TR2) Régulateur électronique de vitesse en approche.

Le réglage de la vitesse lente s’effectue en agissant sur le trimmer LOW SPEED par l’intermédiaire duquel il est possible de varier la tension de sortie sur le(s) moteur(s) (en le tournant dans le sens des aiguilles d’une montre, la vitesse augmente). Le réglage est nécessaire afin de déterminer la bonne vitesse en fin d’ouverture ainsi qu’en fin de fermeture en fonction de la structure du portail ou en présence de légers frottements qui pourraient compromettre le bon fonctionnement du système.

TRIMMER DE FERMETURE AUTOMATIQUE TCA (TR3) TOTALE OU PIETONNE NON

HABILITE par défaut et DEL DL6 ETEINTE (TRIMMER COMPLETEMENT REGLE DANS LE

SENS INVERSE DES AIGUILLES D’UNE MONTRE)

Avec ce trimmer, il est possible d’effectuer le réglage du temps de pause avant la fermeture complète ou piétonne. Ce temps de pause s’active seulement avec une porte totalement ou partiellement ouverte (piétonne) et avec la DEL DL6 allumée ( le trimmer doit être réglé dans le sens des aiguilles d’une montre).

Le temps de pause peut varier de 2 secondes à 2 minutes, selon le réglage.

SIGNALISATIONS LED

DL1 programmation active (rouge)

DL2 portail en phase d’ouverture M2 (vert)

DL3 portail en phase de fermeture M2 (rouge)

DL4 portail en phase d’ouverture M1 (vert)

DL5 portail en phase de fermeture M1 (rouge)

DL6 signalisation temps de fermeture automatique (rouge)

DL7 contact photocellules (NC) (rouge)

DL8 contact tranche de sécurité (NC) (rouge)

DL9 commande bouton STOP (NC) (rouge)

DL10 programmation codes radio (vert)

FUSIBLES

Fuse 1 T 8A FUSIBLE DE PROTECTION DES MOTEURS

F1 T 2A

FUSIBLE DE PROTECTION DU TRANSFORMATEUR (extérieur à la carte T2 24V)

C - CONTRÔLE DU SENS DE ROTATION DU/DES MOTEUR/S

1 - Mettre DIP 1 sur ON => la DEL DL1 commence à clignoter.

2 - Presser et maintenir enfoncé le poussoir PROG (le mouvement est alors effectué en présence de l’utilisateur,, avec séquence ouvrir-stopper-fermer-stopper-ouvrir-etc.) => les DEL vertes DL2 et DL4 s’allument et le portail s’ouvre avec un décalage constant de

2 sec. S’il se ferme au lieu de s’ouvrir; relâcher le bouton-poussoir et inverser les deux fils du moteur en question.

3 - A la fin de l’ouverture, relâcher le pressoir PROG et effectuer la mise au point des arrêtoirs mécaniques d’ouverture (présents sur l’opérateur).

4 - Pousser et maintenir enfoncé le pressoir PROG => LES DEL ROUGES DL3 et DL5 s’allument et le portail se ferme avec un décalage de 2 sec.

5 - Maintenir enfoncé le pressoir PROG jusqu’à ce que le portail ne soit complètement fermé.

6 - Laisser les deux portes totalement fermées pour effectuer la programmation des temps.

7 - Repositionner DIP 1 sur OFF => la DEL DL1 s’éteint indiquant la sortie de la procédure du contrôle.

N.B.: Pendant ce contrôle, l’arrêt d’urgence, les photocellules et les tranches de sécurité ne sont pas activés.

D - PROGRAMMATION DES TEMPS POUR 2 MOTEURS (#) AVEC DETECTEUR

DE COURANT ACTIVE (DIP 7 ON)

PENDANT LA PROGRAMMATION LE DETECTEUR DE COURANT EST TOUJOURS ACTIF.

1 - Le portail doit être totalement fermé.

2 - Mettez le DIP 2 sur ON => la DEL DL1 émettra des clignotements brefs.

3 - Appuyez le pressoir PROG => la porte M1 s’ouvre.

Une fois l’arrêtoir mécanique d’ouverture rejoint, le DETECTEUR DE COURANT

AUTOMATIQUE arrête M1 (avec mémorisation du temps et du courant) => En même temps la porte M2 s’active et s’ouvre.

5 - Une fois l’arrêtoir mécanique d’ouverture rejoint, le DETECTEUR DE COURANT

AUTOMATIQUE arrête M2 (avec mémorisation du temps et du courant).

6 - Lorsque le pressoir PROG est enfoncé => M2 ferme.

7 - Lorsque le pressoir PROG est enfoncé => M1 ferme en déterminant l’écart de décalage entre M2 et M1. Au même moment la DEL DL1 s’arrêtera de clignoter indiquant la fin de la procédure d’apprentissage.

A partir de ce moment, les sécurités ou les autres commandes du portail fonctionneront normalement (inversions, arrêt, alarmes, etc.).

8 - La fermeture des portes sera effectuée en mode rapide (et à l’approche de la fermeture totale en mode ralenti (selon ce qui aura été établi sur le trimmer LOW SPEED)

9 - A la fermeture totale, les détecteurs de courant arrêtent le portail.

10 -

A LA FIN DE LA PROGRAMMATION REMETTRE LE DIP 2 SUR OFF.

D - PROGRAMMATION DES TEMPS POUR 1 MOTEUR (M1) (#) AVEC CAPTEUR

DE COURANT ACTIVE (DIP 7 ON)

ATTENTION: POUR NE GERER QU’UN MOTEUR LE DIP 13 DOIT ETRE POSITIONNE SUR

22

ON. PENDANT LA PROGRAMMATION LE DETECTEUR DE COURANT EST TOUJOURS

ACTIVE.

Le portail doit être totalement fermé.

1 - Mettez DIP 2 sur ON => la DEL DL1 émettra des clignotements brefs.

2 - Appuyez sur le pressoir PROG => M1 s’ouvre.

Une fois l’arrêtoir mécanique d’ouverture rejoint, le DETECTEUR DE COURANT arrête M1

(avec mémorisation du temps et du courant).

3 - Appuyez sur le pressoir PROG => M1 se ferme.

Au même moment la DEL DL1 s’arrêtera de clignoter indiquant la fin de la procédure d’apprentissage. A partir de ce moment, les sécurités ou les autres commandes fonctionneront normalement (inversions, arrêts, alarmes, etc.).

A la fermeture complète, le portail s’arrête grâce au détecteur de courant.

4 -

A LA FIN DE LA PROGRAMMATION REMETTRE DIP 2 SUR OFF.

(#) PENDANT LA PROGRAMMATION LES SECURITES SONT ACTIVEES ET ARRETENT LA

PROGRAMMATION (LA LED DL1, QUI CLIGNOTAIT, RESTE ALLUMEE). POUR REPETER

LA PROGRAMMATION POSITIONNER DIP 2 SUR OFF, FERMER LE PORTAIL GRACE A

LA PROCEDURE “CONTROLE SENS DE ROTATION DES MOTEURS” ET REPETER LA

PROGRAMMATION CHOISIE.

D PROGRAMMATION DES TEMPS POUR 2 MOTEURS (#) AVEC

FONCTIONNEMENT PREPROGRAMME (DIP 7 OFF)

1 - Le portail doit être totalement fermé.

2 - Mettez le micro-interrupteur DIP 2 sur ON => la DEL DL1 clignotera rapidement.

3 - Appuyez sur le pressoir PROG => M1 s’ouvre.

4 - Une seconde après que l’arrêtoir mécanique d’ouverture a été rejoint, appuyez sur le pressoir PROG. => M1 s’arrête et M2 s’ouvre.

5 - Une seconde après que l’arrêtoir mécanique d’ouverture a été rejoint, appuyez sur le pressoir PROG. => M2 s’arrête.

6 - Appuyez sur le pressoir PROG => M2 se ferme.

7 - Appuyez sur le pressoir PROG => M1 se ferme en déterminant le décalage entre M2 et M1.

Au même moment la DEL DL1 s’arrêtera de clignoter indiquant la fin de la procédure d’apprentissage.

A partir de ce moment, les sécurités ou les autres commandes du portail fonctionneront normalement (inversions, stops, alarmes, etc.).

8 - Fini le compte à rebours le portail s’arrête.

9 - A LA FIN DE LA PROGRAMMATION REMETTRE LE DIP 2 SUR OFF.

REMARQUE: Le ralentissement est déterminé automatiquement par le tableau électronique en phase de programmation des temps et est activé environ 50-60 cm avant que les fins de courses mécaniques d’ouverture et de fermeture soient rejoints.

D PROGRAMMATION DES TEMPS POUR 1 MOTEUR (#) AVEC

FONCTIONNEMENT PREPROGRAMME (DIP 7 OFF)

ATTENTION: POUR NE GERER QU’UN SEUL MOTEUR LE DIP 13 DOIT ETRE POSITIONNE

SUR ON

1 - Le portail doit être totalement fermé.

2 - Mettez le micro-interrupteur DIP 2 sur ON => la DEL DL1 émettra des clignotements brefs.

3 - Appuyez sur le pressoir PROG => M1 s’ouvre.

4 - Une seconde après que l’arrêtoir mécanique d’ouverture a été rejoint, appuyez sur le pressoir PROG. => M1 s’arrête.

5 - Appuyez sur le pressoir PROG => M1 se ferme.

Au même moment la DEL DL1 s’arrêtera de clignoter indiquant la fin de la procédure d’apprentissage.

A partir de ce moment, les sécurités ou les autres commandes du portail fonctionneront normalement (inversions, stops, alarmes, etc.).

8 - Fini le compte à rebours le portail s’arrête.

9 -

A LA FIN DE LA PROGRAMMATION REMETTRE LE DIP 2 SUR OFF.

PROGRAMMATION DES TEMPS D’OUVERTURE PIETONNE (#) EN

FONCTIONNEMENT PREPROGRAMME OU AVEC DETECTEUR DE COURANT

Une fois le portail fermé:

1 - Mettre d’abord le DIP 2 sur ON (la DEL DL1 clignote rapidement) et ensuite le DIP1 sur

ON (la DEL DL1 clignotera lentement).

2 - Appuyer sur le bouton-pressoir piéton (COM-PED-BUTT) => M1 s’ouvre.

3 - Appuyer sur le bouton-pressoir piéton pour arrêter la course (définissant ainsi l’ouverture de M1).

4 - Appuyez sur le bouton-pressoir piéton pour démarrer la fermeture.

5 - Au moment de la fermeture, remettre les DIP 1 et 2 sur OFF.

(#) PENDANT LA PROGRAMMATION, LES SECURITES SONT ACTIVEES ET ARRETENT LA

PROGRAMMATION (LA DEL DL1, QUI CLIGNOTAIT, RESTE ALLUMEE). POUR REPETER

LA PROGRAMMATION, POSITIONNER LES DIP 1 ET 2 SUR OFF, FERMER LE PORTAIL

EN SUIVANT LA PROCEDURE “CONTROLE SENS DE ROTATION DES MOTEURS” ET

REPETER LA PROGRAMMATION CHOISIE.

E - PROGRAMMATION DES CODES RADIO POUR OUVERTURE TOTALE

(62 CODES MAXIMUM - UNIQUEMENT POUR LES MODELES CRX)

La programmation ne peut se faire que lorsque le portail est fermé.

1 - Positionner DIP 1 sur ON, puis le DIP 2 sur ON.

2 - La DEL rouge DL1 de programmation clignote avec une fréquence de 1 sec. ON et 1 sec.

OFF pendant 10 secondes.

3 - Appuyer sur la touche de la télécommande (normalement le canal A) dans les 10

secondes. Si la télécommande est correctement mémorisée la DEL DL10 (verte) émet un clignotement.

4 - Le temps de programmation des codes se renouvelle automatiquement pour pouvoir mémoriser la télécommande suivante.

5 - Pour terminer la programmation, laisser s’écouler 10 sec, ou bien appuyer pendant un moment sur le pressoir PROG. La DEL rouge DL1 de programmation arrête de clignoter.

6 - Repositionner DIP 1 sur OFF et DIP 2 sur OFF.

7 - Fin de la procédure.

PROCEDURE D’EFFACEMENT DE TOUS LES CODES RADIO RESERVES A L’OUVERTURE

TOTALE

L’effacement ne peut s’effectuer que lorsque le portail est fermé.

1 - Positionner le DIP 1 sur ON et ensuite le DIP 2 sur ON.

2 - La DEL rouge DL1 de programmation clignote avec une fréquence de 1 sec. ON et 1 sec.

OFF pendant 10 secondes.

3 - Enfoncé et maintenir appuyé le pressoir PROG pendant 5 secondes. L’effacement de la mémoire est indiquée par deux clignotements de la DEL verte DL10.

4 - La DEL rouge DL1 de programmation reste active et il est impossible d’insérer de nouveaux codes comme dans la procédure décrite ci-dessus.

5 - Repositionner DIP 1 sur OFF et DIP 2 sur OFF.

6 - Fin de la procédure.

SIGNALISATION MEMOIRE SATUREE CODES RADIO RESERVES A L’OUVERTURE TOTALE

La signalisation ne s’obtient que lorsque le portail est fermé.

1 - Positionner le DIP 1 sur ON et ensuite le DIP 2 sur ON.

2 - La DEL verte DL10 clignote 6 fois, indiquant la saturation de la mémoire (62 codes présents).

3 - Ensuite la DEL DL1 de programmation reste active pendant 10 secondes, rendant possible l’effacement total des codes.

4 - Repositionner DIP 1 sur OFF et DIP 2 sur OFF.

5 - Fin de la procédure.

le portail est ouvert, il le ferme. S’il est actionné pendant la fermeture du portail, il le rouvre.

POUSSOIR D’OUVERTURE (COM-OPEN)

Lorsque le portail est fermé, le poussoir commande le mouvement d’ouverture. S’il est actionné pendant la fermeture du portail, il le rouvre.

FONCTION HORLOGE DU POUSSOIR D’OUVERTURE

Si vous souhaitez appliquer une horloge (ou plus simplement un commutateur) pour ouvrir et maintenir ouverte la porte, vous devez prendre T2 24V avec fw

03 NOUP.

Si fw 03 ou supérieur ATTENTION: EN CAS DE PANNE D’UNE SÉCURITÉ, UNE

MINUTE APRÈS CETTE HORLOGE OU UN COMMUTATEUR ONT ÉTÉ ACTIVÉS, LA

PORTE S’OUVRE SANS SECURITES ACTIFS!

Cette fonction est utile dans les heures de pointe, quand la circulation est ralentie (ex. entrée/sortie des ouvriers, urgences en zone résidentielle ou dans les parkings et, occasionnellement, pendant les déménagements).

MODALITÉ D’APPLICATION FONCTION HORLOGE

Demander T2 24V avec firmware 02. En connectant un interrupteur et/ou une horloge de type quotidien/hebdomadaire (à la place ou en parallèle du poussoir d’ouverture N.O. “COM-

OPEN”), il est possible d’ouvrir et de maintenir l’automatisme ouvert tant que l’interrupteur est enfoncé ou que l’horloge reste active. Lorsque l’automatisme est ouvert, toutes les fonctions de commandes sont bloquées. En relâchant l’interrupteur, ou au terme de l’heure fixée, l’automatisme se fermera immédiatement.

F - PROGRAMMATION CODES RADIO OUVERTURE PIETONNE (62 CODES

MAXIMUM - UNIQUEMENT POUR LES MODELES CRX)

1 - Positionner DIP 1 sur ON et ensuite DIP 3 sur ON.

2 - La DEL rouge DL1 de programmation clignote avec une fréquence de 1 sec. ON et 1 sec.

OFF pendant 10 secondes.

3 - Appuyer sur la touche de la télécommande (normalement sur le canal B) dans les 10 secondes. Si la télécommande est correctement mémorisée la DEL DL10 (verte) émet un clignotement.

4 - Le temps de programmation des codes se renouvelle automatiquement pour pouvoir mémoriser la télécommande suivante.

5 - Pour terminer la programmation, laisser s’écouler 10 sec, ou bien appuyer pendant un instant sur le pressoir PROG. La DEL rouge DL1 de programmation arrête de clignoter.

6 - Repositionner DIP 1 sur OFF et DIP 3 sur OFF.

REMARQUE: SI LA DEL DL1 CONTINUE DE CLIGNOTER RAPIDEMENT, CELA SIGNIFIE

QUE LE DIP 1 EST ENCORE SUR LA POSITION ON ET QUE N’IMPORTE QUELLE

MANŒUVRE SERA REFUSEE.

7 - Fin de la procédure.

PROCEDURE D’EFFACEMENT DE TOUS LES CODES RADIO RESERVES A L’OUVERTURE

PIETONNE

L’effacement ne peut s’effectuer que lorsque le portail est fermé.

1 - Positionner le DIP 1 sur ON et ensuite le DIP 3 sur ON.

2 - La DEL rouge DL1 de programmation clignote avec une fréquence de 1 sec. On et 1 sec.

OFF pendant 10 secondes.

3 - Enfoncer et maintenir appuyé le pressoir PROG pendant 5 secondes. L’effacement de la mémoire est indiqué par deux clignotements de la DEL verte DL10.

4 - La DEL rouge DL1 de programmation reste active et il est possible d’insérer des nouveaux codes comme dans la procédure décrite ci-dessus.

5 - Repositionner DIP1 sur OFF et DIP3 sur OFF.

6 - Fin de la procédure.

SIGNALISATION MEMOIRE SATUREE CODES RADIO RESERVES A L’OUVERTURE

PIETONNE

La signalisation ne s’obtient que lorsque le portail est fermé.

1 - Positionner le DIP 1 sur ON et ensuite le DIP 3 sur ON.

2 - La DEL verte DL clignote 6 fois indiquant la saturation de la mémoire (62 codes présents).

3 - Puis la DEL DL1 de programmation reste active pendant 10 secondes, rendant possible l’effacement total des codes.

4 - Repositionner DIP 1 sur OFF et DIP 3 sur OFF.

5 - Fin de la procédure.

POUSSOIR DE FERMETURE (COM-CLOSE)

Lorsque le portail est fermé, il commande le mouvement de fermeture.

TELECOMMANDE

Si DIP 6 est sur OFF => Il effectue une commande cyclique des commandes ouvrir - stopper - fermer - stopper - ouvrir etc.

Si DIP 6 est sur ON => Il effectue l’ouverture, quand le portail est fermé. S’il est actionné pendant le mouvement d’ouverture, cela ne produit aucun effet.

S’il est actionné lorsque le portail est ouvert, il le ferme. S’il est actionné pendant la fermeture du portail, il le rouvre.

BOUTON OUVERTURE PIETONNE (COM-PED-BUTT)

Commande réservée à l’ouverture partielle et à la refermeture.

Pendant l’ouverture, la pause ou la fermeture piétonne, il est possible de commander l’ouverture depuis n’importe quelle commande raccordée à la carte T2 24V.

Par l’intermédiaire du DIP 6, il est possible de choisir le mode de fonctionnement du bouton de commande piétonne.

Si DIP 6 est sur OFF => Il effectue une commande cyclique des commandes ouvrir - stopper - fermer - stopper - ouvrir etc.

Si DIP 6 est sur ON => Il effectue l’ouverture, quand le portail est fermé. S’il est actionné pendant le mouvement d’ouverture, cela ne produit aucun effet.

S’il est actionné lorsque le portail est ouvert, il le ferme. S’il est actionné pendant la fermeture du portail, il le rouvre.

VERROULLAGE ELECTRIQUE (LOCK)

Mettre le DIP 8 sur ON pour activer la commande de verrouillage électrique en phase d’ouverture.

COUP DE DESENCLENCHEMENT DE LA SERRURE ELECTRIQUE EN OUVERTURE

Mettre le DIP 9 sur ON pour activer le coup de désenclenchement de la serrure électrique en ouverture (à condition que le DIP 8 soit sur ON).

Lorsque le portail est fermé, si une commande d’ouverture est engagée, le portail effectue la manœuvre de fermeture pendant 0,5s et en même temps la serrure électrique est activée(suivi par 0,5s de pause et ensuite par l’ouverture du portail).

COUP D’ENCLENCHEMENT DE LA SERRURE ELECTRIQUE

Mettre le DIP 10 sur ON pour activer le coup d’enclenchement de la serrure électrique en phase de fermeture. Une fois la fermeture terminée, les moteurs sont commandés à pleine tension pour garantir l’enclenchement de la serrure.

FONCTIONNEMENT DES ACCESSOIRES DE COMMANDE

ATTENTION: CONNECTER LES ACCESSOIRES A COMANDE SEULEMENT SI

IMPULSIVE.

Faire attention que des autres accessoires pour le commande (p.e. senseurs magnétique) sont programmée avec modalité IMPULSIVE, ou contraire, le mouvement est sans sécurité.

POUSSOIR DE COMMANDE PAS-A-PAS (COM-K BUTTON)

DIP 6 OFF => Il effectue une commande cyclique des commandes ouvrir - stopper - fermer

- stopper - ouvrir etc.

DIP 6 ON => Il effectue l’ouverture, quand le portail est fermé. S’il est actionné pendant le mouvement d’ouverture, cela ne produit aucun effet. S’il est actionné lorsque

FACILITATION DU DEBLOCAGE DES MOTEURS

Mettre le DIP 11 sur ON pour activer la facilitation au déblocage manuel (à condition que le

DIP 10 soit positionné sur ON), une fois la fermeture terminée, une manœuvre d’inversion sera exécutée avec un temps fixe de 0,2s pour faciliter le déblocage manuel.

FONCTIONNEMENT DES ACCESSOIRES DE SECURITE

23

PHOTOCELLULE (COM-PHOT)

DIP 4 OFF => Si un obstacle est interposé entre les photocellules lorsque le portail est fermé, celui-ci ne s’ouvre pas. Quand le portail est en fonctionnement, les photocellules interviennent aussi bien pendant l’ouverture (avec reprise du mouvement en ouverture qu’après de la libération des photocellules), que pendant la fermeture (avec reprise du mouvement inverse qu’après de la libération des photocellules).

F

F

DIP 4 ON => Si un obstacle est interposé entre les photocellules lorsque le portail est fermé et que l’ouverture est actionnée, le portail s’ouvre (pendant l’ouverture les photocellules n’interviendront pas). Elles n’interviendront que pendant la phase de fermeture (avec rétablissement du mouvement inverse après une seconde même si les photocellules sont encore occupées).

GESTION FERMETURE IMMEDIATE APRES PASSAGE DEVANT LES PHOTOCELLULES

DIP 16 ON et DIP 4 OFF => Comme le portail s’ouvre, en passant devant les photocellules, le portail s’arrête. Terminé de transit, après 1 seconde, le portail se ferme.

DIP 16 ON et DIP 4 ON => Comme le portail s’ouvre, en passant devant les photocellules, le portail continue à s’ouvrir. Terminé de transit, le portail s’arrête et après 1 seconde de pause il invertit le mouvement en fermeture.

Si l’ouverture totale a lieu (fin du temps d’ouverture), la fermeture immédiate est désactivée et le temps de fermeture automatique est activé (si le trimmer TCA est activé et la DEL DL6 allumée).

S’il y a un passage rapide pendant la fermeture (par ex. un piéton) le portail se ré-ouvrira pendant deux secondes pour se refermer ensuite.

DIP 12 OFF => la fermeture immédiate après passage devant les photocellules est désactivée.

N. B. : Il est recommandé de contrôler le fonctionnement des photocellules au moins tous les 6 mois.

EDGE (BARRE PALPEUSE) (COM-EDGE)

Pendant l’ouverture, si elle est activée, elle change le mouvement en fermeture.

Pendant la fermeture, si elle est activée, elle change le mouvement en ouverture.

Si elle reste occupée après la première activation, elle effectue une nouvelle inversion après

2 secondes, pour ensuite en faire une autre plus petite et donc signaler l’alarme de barre palpeuse en panne ou occupée (contact NO). Si la barre palpeuse reste occupée (contact

NO), aucune manutention n’est permise. Si vous n’en utilisez pas, ponter les bornes COM-

EDGE.

MONITORAGE DES BARRES PALPEUSES DE SECURITE (A+TEST A-)

Grâce à l’entrée A+TEST et au DIP 12 en position ON, il est possible de contrôler la/les barre(s) palpeuse(s). Le monitorage est un Test de Fonctionnement de la barre palpeuse, exécuté à la fin de chaque ouverture totale du portail.

Après chaque ouverture, la fermeture du portail n’est donc possible que si la/les barre(s) palpeuse(s) ont passé le Test de Fonctionnement.

ATTENTION: LE MONITORAGE DE L’ENTREE BARRE PALPEUSE PEUT ETRE ACTIVE EN

METTANT LE DIP 12 SUR ON, OU BIEN DESACTIVE EN POSITIONNANT LE DIP 12 SUR

OFF. EN EFFET, LE TEST DE FONCTIONNEMENT N’EST POSSIBLE QUE DANS LE CAS OU

IL S’AGIT DE DISPOSITIFS DOTES DE LEUR PROPRE ALIMENTATION DE CONTROLE. UNE

BARRE PALPEUSE MECANIQUE NE PEUT ETRE MONITOREE, DONC LE DIP 12 DOIT ETRE

POSITIONNE SUR OFF.

ALARME D’AUTOTEST BARRE PALPEUSE (DIP 12 ON)

A la fin de l’ouverture, si le monitorage de la barre palpeuse a un résultat négatif, une alarme, signalée par le clignotant qui reste allumé, intervient. Dans cette situation, la fermeture du portail n’est pas autorisée. Il n’est possible de rétablir le fonctionnement normal qu’en réparant la barre palpeuse et en appuyant sur une des commandes habilitées.

BOUTON DE STOP (COM-STOP)

Durant n’importe quelle opération, le bouton de STOP arrête le portail.

S’il est enfoncé quand le portail est totalement ouvert (ou partiellement en utilisant la commande piétonne), la fermeture automatique est exclue temporairement (si elle est habilitée par le trimmer TCA et la DEL DL6 allumée). Il faut donc effectuer une nouvelle commande pour le qu’il se referme.

Au cycle suivant, la fonction fermeture automatique sera réactivée (si habilitée par le trimmer

TCA et la LED DL6 allumée).

ALARME DU DETECTEUR DE COURANT

La centrale T2 24V est dotée de détecteurs automatiques qui changent le sens du portail en cas d’impacts avec des choses ou des personnes en conformité avec les normes EN en vigueur (toujours vérifier avec les outils appropriés le respect des valeurs imposées par la norme), sans devoir effectuer des réglages particuliers sur la centrale, puisqu’ils sont gérés par un logiciel interne propre.

Si après une première intervention du détecteur de courant en phase d’ouverture ou de fermeture (seulement à grande vitesse), une seconde intervention a lieu, évidemment dans le sens contraire, le portail s’arrête puis inverse son sens pendant 1 seconde.

L’alarme sera signalée par le clignotant qui restera actif durant une minute, pendant ce temps, il est possible de rétablir le fonctionnement du portail en appuyant sur n’importe quel bouton de commande.

TRAVAIL AVEC HOMME PRESENT, DANS LE CAS DE PANNE DE SÉCURITÉ

Si le barre palpeuse est en panne ou engagé pour plus de 5 secondes, ou si la cellule photoélectrique est en panne ou engagée pour plus de 60 secondes, les commandes

OUVERTURE, FERMETURE, K BOUTON ET PIETONS fonctionnent seulement à homme present.

La signalisation de l’activation de cette opération est donnée par la LED de programmation qui clignote.

Avec cette opération est autorisée l’ouverture ou fermeture seulement en appuyant sur les boutons de contrôle. Le contrôle radio et la fermeture automatique sont exclues parce que leur fonctionnement n’est pas autorisé par les règles.

A la restauration du contact de sécurité, l’opération automatique ou pas à pas est restaurée après une seconde, et donc aussi la télécommande et la fermeture automatique sont de travail.

Note 1: Au cours de cette opération dans le cas de panne de les barres palpeuses (ou cellules photoélectriques) les cellules photoélectriques (ou barres palpeuses) qui ne sont pas en panne, fonctionnent encore avec l’interruption de l’opération en cours.

Note 2: Le bouton d’arrêt n’est pas considéré comme un contournement de la sécurité dans ce mode, si il est pressé ou en panne, il ne permet pas de tout mouvement.

La manoeuvre à homme present est exclusivement une manoeuvre d’urgence qui doit

être effectuée pour des temps brefs et avec la sécurité de la vue quand l’opérateur est en mouvement. Dès possible les protections en panne doivent être rétablies pour un correct fonctionnement.

FEU CLIGNOTANT

N.B.: Ce tableau électronique peut alimenter QUELES FEUX CLIGNOTANTS AVEC CIRCUIT

CLIGNOTANT (ACG7061) avec ampoule de 24V et 20W maximum.

FONCTION PRE-CLIGNOTEMENT

DIP 5 - OFF => le moteur et le feu clignotant démarrent en même temps.

DIP 5 - ON => le feu clignotant démarre 3 secondes avant le moteur.

VOYANT DE SIGNALISATION PORTAIL OUVERT (COM-SIGNAL)

Il a pour tâche de signaler si le portail est ouvert, partiellement ouvert ou encore pas totalement fermé. Il ne s’éteint que lorsque le portail est complètement fermé.

Pendant la programmation, cette signalisation est active.

N.B.: Maximum 3 W. Si la consommation des boîtiers de commande ou des ampoules dépasse ce seuil, la logique du tableau électronique en sera compromise, engendrant un possible blocage des opérations.

FONCTIONNEMENT APRES COUPURE DE COURANT (SANS PILES)

Au retour de la courant la led DL1 s’allume et reste allumée pendant tout le temps que le portail reste ouvert. Elle s’éteindra à la complète fermetre du portail.

Il est conseillé d’ouvrir complètement le portail. Laissez le portail se fermer tout seul avec la fermeture automatique ou attendez que le feu clignotant arrête de clignoter avant de commander la fermeture.

Cette opération permettra au portail de se réaligner. En effet, si les moteurs se sont bloqués et ont été déplacés de la position normale de fermeture pendant la coupure de courant, la première manœuvre au retour de l’alimentation doit être complète.

Si le black-out se passe pendant le mouvement, ou avec le portail ouvert, et la première commande est celle de fermeture, la fermeture se passera avec déphasage totale des portes donc M2 se fermera avant et M1 se fermera après. Le mouvement separé des deux moteurs évitera que les portes se touchent.

CARACTERISTIQUES TECNIQUES

- Intervalle de température

- Humidité

- Tension d’alimentation

- Fréquence

- Alimentation batterie

- Puissance du transformateur

- Consommation maximale

- micro-interrupteurs de réseau

- Puissance maximale voyant portail ouvert

0 ÷ 55°C

< 95% sans condensation

230V~ ± 10% (120/60 Hz sur demande)

50/60 Hz

20-24VCC

130VA primaire 230Vac secondaire 18Vac

50 mA

100ms

24Vdc 3W (équivalent à une petite lampe de 3W ou à 5 DEL avec résistance en série de 2,2 k ohm)

- Charge maximale feu clignotant 24Vdc 20W

- Courant disponible pour photocellules et accessoires 1A ±15%

- Courant disponible sur le connecteur radio 200mA

CARACTERISTIQUES TECHNIQUES RADIO (modèle T2 24V crx)

- Fréquence réception

- Impédance

- Sensibilité

- Temps d’excitation

433,92MHz

52 OHM

>2,24µV

>2,24µV

- Temps de désexcitation 300ms

- Toutes les entrées doivent être utilisées avec des contacts propres car l’alimentation est générée à l’intérieur de la carte (tension sûre) pour garantir le respect de la double isolation et de l’isolation renforcée par rapport aux parties sous tension dangereuse.

- Les éventuelles connexions de circuits externes aux sorties du tableau électronique doivent

être faites pour garantir la double isolation ou l’isolation renforcée par rapport aux parties sous tension dangereuse.

- Toutes les entrées sont gérées par un circuit programmé intégré qui exécute un autocontrôle à chaque mise en route.

24

SOLUTION DES PROBLEMES

Après avoir effectué tous les raccordements en suivant attentivement le schéma et avoir positionné le portail en position intermédiaire, vérifier l’allumage correct des leds rouges DL7, DL8 et DL9.

Si les leds ne s’allument pas, en maintenant toujours le portail en position intermédiaire, vérifier les points ci-après et éventuellement remplacer les composants qui ne fonctionnent pas.

DL7 éteinte Photocellules en panne

DL8 éteinte Bande de contact de sécurité en panne (Si la bande de contact n’est pas reliée, effectuer la connexion entre COM et EDGE)

DL9 éteinte Bouton de STOP en panne (Dans le cas où le STOP n’est pas connecté, ponter entre COM et STOP).

Durant le fonctionnement avec opérateur présent, avec DIP n° 1 sur ON, vérifier que durant l’ouverture de M1 et M2, les leds vertes DL2 et DL4 s’allument, et que durant la fermeture de

M1 et M2, les leds rouges DL3 et DL5 s’allument.

Dans le cas contraire, intervertir les fils du moteur en question.

DEFAUT SOLUTION

Après avoir effectué les différents raccordements et avoir allumé le courant, toutes les leds sont éteintes.

Vérifier l’intégrité des fusibles F1, FUSE 1.

En cas de fusible hors service, ne remplacer qu’avec des fusibles de valeur adéquate

F1 T 2A FUSIBLE DE PROTECTION TRANSFORMATEUR (extérieur à la carte T2 24V)

FUSE 1 8A FUSIBLE DE PROTECTION MOTEURS

Le moteur ouvre et ferme, mais n’a pas de force et se déplace lentement.

Vérifier le réglage des trimmers RUN et LOW-SPEED.

Le portail effectue l’ouverture, mais ne se referme pas après le temps configuré.

S’assurer que le trimmer TCA est habilité avec la DEL DL6 allumée.

Si le bouton OPEN est toujours enfoncé, remplacer le bouton ou le boîtier de commande OPEN. Si l’autotest de la barre palpeuse est négatif, vérifier les connexions entre le tableau électronique et l’alimentation de la/ des barre(s) palpeuse(s). Attention: Si vous n’utilisez pas un boîtier d’alimentation pour la barre palpeuse, le

DIP 12 doit être positionné sur OFF.

Le portail ne s’ouvre pas et ne se referme pas en actionnant les différents boutons K, Radio, Open et Close.

La serrure électrique ne fonctionne pas.

La DEL DL1 clignote rapidement et aucune manutention n’est habilitée.

Contact bande de contact de sécurité en panne. Contact photocellules en panne avec DIP 4 OFF. Replacer ou remplacer le contact correspondant.

S’assurer d’avoir activé le DIP 8 sur ON.

Positionner les DIP switch 1, 2 ou 3 sur OFF.

OPTIONS -

Pour les branchements et les données techniques des accessoires, se conformer aux livrets d’instruction correspondants.

FICHE DE CHARGE BATTERIE

VERROU MECANIQUE

F

BATTERIE

Batterie 2,2Ah 12V code ACG4648

Pour le verrouillage au sol du premier vantail

SERRURE ELECTRIQUE

code ACG5000 code ACG9515

25

Serrure Horizontale - droite vue externe - 12Vac

Serrure Horizontale - gauche vue externe - 12Vac

Serrure Verticale - 12Vac code ACG8660 code ACG8670 code ACG8650

F

T2 24V Wi-Fi

Tableau avec détecteurs d’impacts et carte MASTER Wi-Fi.

Avec boîtier. code ABT2025W

Wi-Fi DEVICES

MASTER Wi-Fi

FICHE DE GESTION SYSTÈME SANS FILS embrochable - 12÷30V ac/dc avec bornes à visser - 12÷30V ac/dc

NOVA Wi-Fi

PHOTOCELLULES SANS FILS

PAIRE DE POTEAUX NOVA

BLOCK Wi-Fi

code ACG6094 code ACG6099

VERTIGO Wi-Fi

code ACG8037 code ACG8039

WIRELESS PHOTOCELLS SUBSTITUTING THE SAFETY STRIP

VERTIGO Wi-Fi 8 code ACG8042 - VERTIGO Wi-Fi 10 code ACG8043

SPARK Wi-Fi

SÉLECTEUR À CLÉ SANS FILS code ACG6098

26

FEU CLIGNOTANT SANS FILS

SUPPORT LATERAL code ACG7064 code ACG7042

SYSTEM LAY-OUT

2

5 1

1 - PRINCE 24V operator

2 - Tuned aerial

3 - Flashing lamp

4 - Key selector

5 - Photoelectric cells (external)

1 5 4

3

4

1

TECHNICAL FEATURES

PRINCE 24V is a linear operator designed for swing gates long up to 3 m and weight up to 250 kg (Pic. 1).

PRINCE 24V works without electric limit switches, but with mechanical stoppers.

N.B.: It is advisable to fit an electrical lock to ensure an efficient gate locking.

TECHNICAL DATA

Max. gate leaf length

Max. gate leaf weight

Max. travel

Average opening time

Operating speed

EEC Power supply

Nominal Motor capacity

Max Motor capacity (blocked)

Nominal Power absorbed

Max Power absorbed (blocked)

Nominal Thrust force

Max Thrust force (blocked)

Normative cycles

Daily operations suggested

Service

Guaranteed consecutive cycles

Weight of the PRINCE 24V

Noise

Operating temperature

Protection grade m kg mm s.

m/s

% n° kg db

°C

IP

N n°

A

N n°

W

W

A

** With incorporated mechanical stopper that cuts out during opening. If the mechanical stopper is used also during the closing (optional), the maximum stroke is reduced by

30 mm.

PRINCE 24V

3

3,72

1000

1500

∞ - 14s/2s

60

80

60/14s

5

<70

-30 ÷ +55°C

44

250

343**

14

0,0134

24Vdc

12

89

0,88

G

B

27

Measurements in mm

2

G

B

INSTALLATION PRINCE

PRE-INSTALLATION CHECK LIST

The gate leaves must be firmly fixed to the hinges on the gate pillars, they must not flex during the movement and they must swing without any friction.

Before installing the operator, make sure you have enough room to fix the operator on the pillar.

In case the gate is like the one depicted in Pic. 1, there is no need for any modification.

Gate features and installation must comply with local regulations and standards.

The gate can be automated only if it is in good conditions and complies with EN12604 norms.

The gate leaf must not have a pedestrian doors in its frame. Should there be a pedestrian opening, take the appropriate steps according to EN12435 norms (e.g. cutting out the motor when the pedestrian door is opened by fixing a safety micro switch connected to the control board).

Make sure not to create any trapping points or areas (e.g. with the gate completely opened, between any opening in the gate frame and the side wall).

COMMAND TYPE

with manned operation with visible impulses

(e.g. sensor)

Parts to install meeting the EN 12453 standard

Skilled persons

(out of public area*)

A

USE OF THE SHUTTER

Skilled persons

(public area)

B

C or E C or E

Unrestricted use non possibile

C and D, or E with not visible impulses

(e.g. remote control device) automatic

C or E C and D, or E C and D, or E

C and D, or E C and D, or E C and D, or E

* a typical example are those shutters which do not have access to any public way

A: Command button with manned operation (that is, operating as long as activated), like code ACG2013

B: Key selector with manned operation, like code ACG1010

C: Adjustable power of the motor

D: Safety strips and/or other safety devices to keep thrust force within the limits of EN12453 regulation - Appendix A.

E: Photocells, like code ACG8026 (To apply every 60÷70cm for all the height of the column of the gate up to a maximum of 2,5m - EN 12445 point 7.3.2.1)

EMERGENCY MANUAL RELEASE

This applies only if the unit is not equipped with back-up batteries. In case of a black-out, the gate can be pulled open after the operator has been unlocked with the emergency key provided

(rotate the key by 90° clockwise, Pic. 3).

Caution

In order to be able to manually open the gate leaf make sure of the following:

- The gate leaves must be endowed with appropriate handles;

- Position of the handles onto the gate leaves must be in risk free area;

- The manual force necessary to move the gate leaves should not be higher than 225 N, in case of installations at domestic/private dwellings, and 390N in case of installations in business premises (according to points 5.3.5 of the EN12453 norm).

Note: in case of an installation with an overlapping two leave swing gate to ensure a safe/ proper locking a mechanical bolt must be installed along with an electric lock. The mechanical bolt (ACG5000) must be installed at the bottom of the first gate leaf to close so that it will be simply operated by the pressure of the second gate leaf. The electric lock will simply latch one gate leaf to the other.

FIXING THE ACTUATOR ATTACHMENT TO THE COLUMN

To obtain a correct movement of the gate leaf, it is necessary to comply with the measurements given (Pic. 4, 5, 7, 8, 9)

In case an iron pillar is available, weld the bracket straight to it.

In case you need to fix the bracket onto a concrete pillar, use the fixing plate as shown in picture

4, that will have to be fastened with 4 Fischer screws of Ø 8 mm.

In case you have a wall parallel to gate leaves when in open position, you must allow for a niche in which the operator can fit in.

FIXING THE ACTUATOR ATTACHMENT TO THE GATE

Weld the second bracket to the gate (pictures 6, 9)

During installation make sure to comply with the measurements mentioned in the table below.

Fix the PRINCE and try several times to open and to close the gate, controlling that the cover does not touch the moving gate.

28

3

4

5

Grease thoroughly

YES !

Be sure to tighten the bolt that holds the bracket to the operator so that it can rotate freely.

6

NO !

The operator must not vary its height during the movement.

8

S1

Z

Y

X

S2

Z

Y

X

Comply with the measure and make sure that the operator is horizontal

In order to carry out a proper installation of the operator, it is necessary to comply with the geometry measurement shown in the tables below.

COL

Column attachment

Z

Y

X

S3

Respect the measures for a correct installation

L

Min.÷Max

1÷3 a

A max

B C D E

T sec

COL ANT

90°

0 100 100 765 90 13,5 S2-X A

20 100 100 765 90 13,5

S2-Y A

40 100 100 765 90 13,5 S3-X A

60 110 100 765 90 14 S3-Y A

80 140 110 765 115 17 S3-X B

100 160 110 765 115 18

S3-X B

120 180 110 765 115 19,5 S3-X B

140 210 110 765 115 21,5 S1-Z B

150 220 120 765 115 23 S1-Z B

110°

20 110 140 765 90 17

S1-Y A

Measures WITH 2 MECHANICAL STOPPERS

L

Min.÷Max

1÷3 a

A max

B C D E

T sec

COL ANT

0 100 100 730 90 13,5 S2-X A

20 100 100 730 90 13,5

S2-X A

40 100 100 730 90 13,5 S3-X A

60 110 100 730 90 14 S3-X A

90°

80 140 110 730 115 17 S3-X B

100 160 110 730 115 18

S3-X B

110 180 120 730 115 20 S1-Z B

110°

20 100 140 730 90 16 S2-Y A

ANT

Leaf attachment

A

B

If the pillar is too large, and it is not possible to adjust the actuator complying the measurements (B), you must make a niche in the pillar or you have to move the gate closer to the edge of the pillar.

9

29

G

B

G

B

MECHANICAL STOPPER - OPTIONAL (Code ACG8088)

Optional mechanical stopper to stop the closing, if the gate is not fitted with a floor stopper.

MECHANICAL STOPPER ADJUSTMENT

To adjust the stoppers you have to follow the scheme (Pic. 11).

To set the opening limit it is enough to fix the stopper (A) in the needed position by tightening the 8mA screw with a n. 13 key.

To obtain the desired closing limit you must adjust the stopper (B) (OPTIONAL) in the needed position and tighten it as for stopper (A).

MAINTENANCE

Maintenance should be carried out by skilled and qualified staff only, after switching off the mains supply.

Regularly lubricate the hinges of the gate every 6 months and keep the thrust needed to move the gate leaf monitored (according to EN12453).

ELECTRIC CONNECTIONS

A B

C

30

D

10

11

T2 24V code AC07088

T2 24V CRX code AC07089

ANTENNA

COMMON

CLOSE

OPEN

STOP

ANTENNA

BRAIDING

24Vdc 0,8A ± 15% for ACCESSORY SUPPLY

24Vdc 0,8A ± 15% for AUTOTEST SAFETY STRIPS

BLINKER

24Vdc 20W

LED

PEDESTRIAN

STEP BY STEP

PHOTOCELLS

COMMON

SAFETY STRIPS

R=2,2K 1/4W

ELECTRIC

LOCK

POWER SUPPLY

230Vac 50 Hz

FUSE

T 2 A

TRANSFORMER

G

B

M1

M2

31

G

B

J4

J5

J6

J7

J9

J10

TR1

TR2

TR3

J1

J2

J3

J8

A - CONTROL PANEL FEATURES

N F

COM.

CLOSE

OPEN

STOP

AERIAL

SIGNAL

Power supply 230 Vac 50/60 Hz - external to the control panel - (120V/60Hz upon request)

Common contact

Closing impulse contact (NA)

Opening impulse contact (NA)

STOP impulse contact (NC)

Radio Antenna

Gate open state and battery state output indicator

(24Vdc 3W max)

+ 24Vdc safety strip self-test power supply

Safety strip contact (NC)

A+TEST

EDGE N.C.

COM.

PHOTO N.C.

K BUTT.

PED. BUTT.

A+

A -

LOCK

Common contact

Photocells contact (NC)

Single pulse contact (NO)

Pedestrian opening contact (NA)

+ 24Vdc accessories power supply

- 24Vdc accessories power supply

Electric lock connection (MAX 15W 12V)

- 24Vdc blinker (code ACG7061) power supply. Pay attention to the polarity.

Connection to secondary coil of transformer 18 Vac SECONDARY

TRANSFORMER

MOTOR 1

MOTOR 2

MOTOR 1 CONNECTION (without polarity)

MOTOR 2 CONNECTION (without polarity)

Connector dedicated to the factory programming.

DO NOT REMOVE ANY JUMPER! OTHERWISE THE

OPERATOR WILL NOT WORK!

SW T2 24V

Connector dedicated to the factory programming (only

CRX control board) DO NOT REMOVE ANY JUMPER!

OTHERWISE THE OPERATOR WILL NOT WORK!

SW RADIO

RADIO

BATTERY CHARGER

Built-in radio module (model CRX), or connector for radio receiver RIB, 24 Vdc supply

Connector for charge card of 24Vdc battery (code

ACG4648)

TRIMMER RUN Trimmer for high speed adjustment operations

TRIMMER LOW SPEED Trimmer for low speed adjustment operations

TRIMMER TCA Trimmer for automatic closing time adjustment

(DISABLED DEFAULT AND DL6 LED OFF)

J9

J10

J8

J7

S3

S3 PROG

FUSE 1 T 8 A

F1 T 2 A

J2 J3

J1

TR1

Programming button

Motor protection fuse

Transformer protection fuse

TR2

F1

TRANSFORMER

J4

FUSE 1

J5

J6

TR3

B - SETTINGS

DIP 1 (ON) - MOTOR ROTATION DIRECTION CONTROL (POINT C)

DIP 2 (ON) - TIMER (POINT D)

DIP 3 (ON) - ACTIVATES DOOR RELEASE DURING PHASES OF SLOWDOWN AND

TOTAL OPENING AND CLOSING (AS PER THE IMPACT TESTS OF EN12453)

DIP 1-2 MEMORIZATION/CANCELLATION OF RADIO CONTROL CODES FOR TOTAL

OPENING (ONLY MODEL CRX) (POINT E)

DIP 1-3 MEMORIZATION/CANCELLATION OF RADIO CONTROL CODES FOR PEDESTRIAN

OPENING (ONLY MODEL CRX) (POINT F)

DIP 2-1 MICRO-SWITCH CONTROLLER FOR PEDESTRIAN OPENING TIMER

DIP 4 Photocells always active (OFF) - Photocells active only during closing (ON)

DIP 5 Pre-blinking (ON) - Normal blinking (OFF)

DIP 6 Single pulse command (K BUTT) and step-by-step radio receiver (OFF) - automatic

(ON)

DIP 7 Power sensor operation (ON-activated) time operation (OFF-activated).

DIP 8 Electric lock activation (ON-activated)

DIP 9 Electric lock pulse release (ON-activated)

DIP 10 Electric lock pulse engagement (ON-activated)

DIP 11 Easy release activation (ON-activated)

DIP 12 Sensor TEST activation (ON-activated).

DIP 13 Selection of 1 or 2 motor operation (default OFF 2 motors)

DIP 14 OFF

DIP 15 OFF

DIP 16 IMMEDIATE CLOSING AFTER PASSING IN FRONT OF PHOTOCELLS

ON ACTIVATED

OFF DEACTIVATED

JP1 => Check that the jumper is inserted!

JP2 => Check that the jumper is inserted!

JP3 => Check that the jumper is inserted!

PROG =>

S3 Programming button

ADJUSTMENTS

ATTENTION: PUT DIP 3 IN THE ON MODE ONLY AFTER HAVING CARRIED OUT ALL THE

PROGRAMMING PROCEDURES.

NOTE: WITH DIP 3 (ON) BRIEF GATE REVERSAL AFTER IMPACT IS ACTIVATED.

THIS BRIEF GATE REVERSAL PERMITS STATIC FORCE TO BE REDUCED TO ZERO WITHIN

5 SECONDS AS PER STANDARD EN12453 POINT A.2.2 (ACCEPTABLE STATIC FORCE),

THEREBY COMPLYING WITH THE IMPACT TESTS ALSO OUTLINED BY EN12453).

IF COMPLIANCE WITH THE AFOREMENTIONED STANDARD IS UNNECESSARY, SIMPLY

POSITION DIP 3 TO OFF. IN THIS CASE THE GATES STOP WITHOUT REVERSING.

RUN TRIMMER (TR1) high-speed electronic regulator

This trimmer permits motor speed adjustment (the default setting is maximum speed).

Adjustment of the automation is useful for compliance with European impact standards.

LOW-SPEED TRIMMER (TR2) Electronic slow speed approach control

The slow speed control is performed by adjusting the LOW- SPEED TRIMMER which changes the voltage output across the motor(s) (turning it clockwise increases the speed). Adjustment is performed to determine the correct speed at the end of opening and closing according to the gate or when there is friction that might cause the system to function poorly.

32

AUTOMATIC CLOSING TRIMMER - TCA (TR3) TOTAL OR PEDESTRIAN default NOT

ACTIVATED and LED DL6 OFF (TRIMMER FULLY ROTATED COUNTERCLOCKWISE)

This trimmer makes it possible to adjust the time for total or pedestrian automatic closing.

Only with gate completely (total) or partially (pedestrian) open and LED DL6 on (trimmer rotated clockwise).

The pause time can be adjusted from a minimum of two seconds up to a maximum of two minutes.

LED SIGNALS

DL1 program activated (red)

DL2 gate opening M2 (green)

DL3 gate closing M2 (red)

DL4 gate opening M1 (green)

DL5 gate closing M1 (red)

DL6 automatic closing indicator (red)

DL7 photocell contact (NC) (red)

DL8 sensor contact (NC) (red)

DL9 STOP button (NC) (red)

DL10 radio code program (green)

FUSES

Fuse 1 T 8A MOTOR PROTECTION FUSE

F1 T 2A TRANSFORMER PROTECTION FUSE (on the outside of the T2 24V board)

C - MOTOR ROTATIONAL DIRECTION CONTROL

1 - Set DIP 1 to ON => LED DL1 starts flashing.

2 - Press and hold the PROG button. (movement is now manually controlled - open-stopclose-stop-open - etc.) => GREEN LEDS DL2 and DL4 are lit and the gate panels open with a fixed lag of 2 sec. If they close instead of open, release the button and reverse the two wires on the motor used.

3 - After opening release the PROG button and calibrate the mechanical opening stops (on the operator).

4 - Press and hold the PROG button => RED LEDs DL3 and DL5 turn on and the gate panels close with a time lag of 2 sec.

5 - Continue to hold the PROG button until the gate is completely closed.

6 - Leave the two doors completely closed to set the timer.

7 - Reset DIP1 to OFF => LED DL1 turns off, signaling exit from control.

N.B.: During this check the stop, the photocells and the sensors are not active.

D - SETTING THE TIMER FOR 2 MOTORS (#) WITH POWER SENSOR ACTIVATED

(DIP 7 ON)

WHILE SETTING THE TIMER THE POWER SENSOR IS CONTINUOUSLY ACTIVATED.

1 - The gate must be completely closed.

2 - Set DIP 2 to ON => LED DL1 will blink rapidly.

3 - Press the PROG button. => M1 opens.

4 - When the mechanical opening stop is reached, the AUTOMATIC POWER SENSOR stops

M1 (memorizing the time and the power) => At the same time M2 is triggered to open.

5 - When the mechanical opening stop is reached, the AUTOMATIC POWER SENSOR stops

M2 (memorizing the time and the power).

6 - Press the PROG button. => M2 closes.

7 - Press the PROG button. => M1 closes and sets the lag time between M2 and M1. At the same time LED DL1 stops flashing indicating exit from the programming procedure.

Safety and other gate commands now operate normally (inversions, stop, alarms, etc.).

8 - The gate panels will close in high-speed mode (depending on how you set the RUN trimmer) and near total closure in the slow mode (depending on how you set the LOW-

SPEED trimmer).

9 - Upon closing the power sensors stop the gate.

10 - AFTER PROGRAMMING RESET DIP 2 TO OFF.

D - SETTING THE TIME FOR ONE MOTOR (M1) (#) WITH POWER SENSOR

ACTIVATED (DIP 7 ON)

CAUTION: FOR ONE MOTOR CONTROL DIP 13 MUST BE POSITIONED TO ON; DURING

PROGRAMMING THE POWER SENSOR IS CONTINUOUSLY ACTIVE.

The gate must be completely closed.

1 - Set DIP 2 to ON => LED DL1 will blink rapidly.

2 - Press the PROG button. => M1 opens.

When the mechanical opening stop is reached, the AUTOMATIC POWER SENSOR stops

M1 (memorizing the time and the power).

3 - Press the PROG button. => M1 closes.

At the same time LED DL1 stops flashing indicating exit from programming. Safety and other gate commands now operate normally (inversions, stop, alarms, etc.).

Upon closing the power sensor stops the gate.

4 - AFTER PROGRAMMING RESET DIP 2 TO OFF.

(#) DURING PROGRAMMING THE SAFETY DEVICES ARE ACTIVE AND STOP THE

PROGRAMMING PROCEDURE (LED DL1 FROM FLASHING BECOMES CONSTANT).

TO REPEAT PROGRAMMING SET DIP 2 TO OFF, CLOSE THE GATE USING THE

PROCEDURE “MOTOR ROTATIONAL DIRECTION CONTROL” AND REPEAT THE DESIRED

PROGRAMMING PROCEDURE.

D - SETTING THE TIME FOR 2 MOTORS (#) WITH TIME OPERATION (DIP 7 OFF)

1 - The gate must be completely closed.

2 - Set DIP 2 to ON => LED DL1 will blink rapidly.

3 - Press the PROG button. => M1 opens.

4 - When the mechanical opening stop is reached, wait a second then press the PROG button

=> M1 stops and M2 opens.

5 - When the mechanical opening stop is reached => wait 1 second and press the PROG button => M2 stops.

6 - Press the PROG button => M2 closes.

7 - Press the PROG button => M1 closes setting the time lag between M2 and M1.

At the same time LED DL1 stops flashing indicating exit from the programming procedure.

Safety and other gate commands now operate normally (inversions, stop, alarms, etc.).

8 - After the set amount of time, the gate will stop.

9 - AT THE END OF PROGRAMMING RESET DIP 2 TO OFF.

NOTE: The slowdown is automatically determined by the control board during the time setting phase and is activated at about 50 to 60 cm before reaching the mechanical opening or closing limit.

D - SETTING THE TIME FOR 1 MOTOR (#) WITH TIME OPERATION (DIP 7 OFF)

CAUTION: FOR ONE MOTOR CONTROL DIP 13 MUST SET TO ON

1 - The gate must be completely closed.

2 - Set micro-switch DIP 2 to ON => LED DL1 will blink rapidly.

3 - Press the PROG button => M1 opens.

4 - When the mechanical opening stop is reached, wait a second then press the PROG button

=> M1 stops.

5 - Press the PROG button => M1 closes.

At the same time LED DL1 stops flashing indicating exit from the programming procedure.

Safety and other gate commands now operate normally (inversions, stop, alarms, etc.).

6 - After the set amount of time, the gate will stop.

7 - AT THE END OF PROGRAMMING RESET DIP 2 TO OFF.

D - SETTING PEDESTRIAN OPENING TIMES (#) BOTH FOR TIME AND POWER SENSOR

OPERATION

With gate closed:

1 - First set DIP2 to ON (LED DL1 flashes quickly) and then DIP1 to ON ( LED DL1 flashes slowly).

2 - Push the pedestrian button (COM-PED.BUTT) => M1 opens.

3 - Push the pedestrian button to stop movement (thereby setting M1 opening).

4 - Push the pedestrian button to start closing.

5 - Upon closing reset DIP 1 and 2 to OFF.

(#) DURING PROGRAMMING THE SAFETY DEVICES ARE ACTIVE AND STOP THE

PROGRAMMING PROCEDURE (LED DL1 FROM FLASHING BECOMES CONSTANT).

TO REPEAT PROGRAMMING SET DIP 2 TO OFF, CLOSE THE GATE USING THE

PROCEDURE “MOTOR ROTATIONAL DIRECTION CONTROL” AND REPEAT THE DESIRED

PROGRAMMING PROCEDURE.

E - RADIO CODE PROGRAMMING FOR TOTAL OPENING

(UP TO 62 CODES - CRX MODELS ONLY)

Programming can be done only when the gate is stationary.

1 - First set DIP 1 to ON and then DIP 2 to ON.

2 - The red LED DL1 flashes ON every 1 sec. and OFF for 10 seconds.

3 - Press the remote control button (usually channel A) within the allotted 10 seconds. If the remote is memorized properly LED DL10 (green) blinks.

4 - The programming time for codes is automatically renewed in order to memorize the next remote control.

5 - To finish programming, wait 10 seconds, or press the PROG button briefly. The red LED

DL1 stops flashing.

6 - Reset DIP 1 to OFF and DIP 2 to OFF.

7 - End of procedure.

CANCELLATION OF ALL RADIO CODES FOR TOTAL OPENING

Cancellations can only be performed when gate is stationary.

1 - Set DIP 1 to ON and then DIP 2 to ON.

2 - The red LED DL1 flashes ON every 1 second and OFF for 10 seconds.

3 - Press and hold the PROG button for 5 seconds. Memory cancellation is indicated by two flashes of green LED DL10.

4 - The red LED DL1 remains active and you can add new codes as shown above.

5 - Reset DIP 1 to OFF and DIP 2 to OFF.

6 - End of procedure.

INDICATOR MEMORY FULL OF RADIO CODES FOR TOTAL OPENING

Indication only when gate is stationary.

1 - Set DIP 1 to ON and then DIP 2 to ON.

2 - The green LED DL10 flashes 6 times when the memory is full (62 codes).

3 - LED DL1 will then remain active for 10 seconds enabling possible cancellation of codes.

4 - Reset DIP 1 to OFF and DIP 2 to OFF.

5 - End of procedure.

33

F - PROGRAMMING PEDESTRIAN OPENING RADIO CODES

(UP TO 62 CODES - CRX MODELS ONLY)

Programming can be done only when the gate is stationary.

1 - Set DIP 1 to ON and then DIP 3 to ON.

2 - The red led DL1 flashes ON for 1 second and OFF for 1 second for 10 seconds.

3 - Press the remote control button (usually channel B) within the allotted 10 seconds. If the

G

B

G

B

remote is properly memorized LED DL10 (green) blinks.

4 - The programming time for codes is automatically renewed in order to memorize the next remote control.

5 - To finish programming wait 10 seconds, or press the PROG button briefly. The red LED

DL1 stops flashing.

6 - Reset DIP 1 to OFF and DIP 3 to OFF.

NOTE: If LED DL1 CONTINUES BLINKING QUICKLY IT MEANS THAT DIP 1 IS STILL SET

TO ON AND THAT ANY OPERATION IS REFUSED.

7 - End of procedure.

CANCELLATION PROCEDURE FOR ALL PEDESTRIAN OPENING RADIO CODES

Cancellation can only be performed when the gate is stationary.

1 - Set DIP 1 to ON and then DIP 3 to ON.

2 - The red LED DL1 flashes ON for 1 second and OFF for 1 second for 10 seconds.

3 - Press and hold the PROG button for 5 seconds. Memory cancellation is indicated by two flashes of green LED DL10.

4 - The red LED DL1 remains active and you can add new codes as shown above.

5 - Reset DIP 1 to OFF and DIP 3 to OFF.

6 - End of procedure.

INDICATION MEMORY FULL OF PEDESTRIAN OPENING RADIO CODES

Indication only when the gate is stationary.

1 - Set DIP 1 to ON and then DIP 3 to ON.

2 - The green LED DL10 flashes 6 times when the memory is full (62 codes).

3 - The LED DL1 will then remain active for 10 seconds enabling possible cancellation of codes.

4 - Set DIP 1 to OFF and DIP 3 to OFF.

5 - End of procedure.

CONTROL ACCESSORIES OPERATION

ATTENTION: ONLY IMPULSIVE COMMANDS HAVE TO BE CONNECTED.

Make sure that any other type of command accessories (e.g. mass detectors) used on the installation are set in the IMPULSIVE mode, otherwise, the gate will be operated even without the protection of the safety devices.

ELECTRIC LOCK (LOCK)

Set DIP 8 to ON to enable control of the electric lock when opening.

ELECTRIC LOCK PULSE RELEASE IN OPENING

Set DIP 9 to ON to enable the electric lock pulse release when opening (provided DIP 8 is ON).

If a command to open the gate is given when the gate is closed, the closing movement is performed for 0.5 seconds and the electric lock is simultaneously activated (followed by a 0.5 second pause and then the opening of the gate).

ELECTRIC LOCK PULSE ENGAGEMENT

Set DIP 10 to ON to enable the pulse engagement of the electric lock when closing. Upon closing, motors are activated for 0.5 seconds at full voltage to ensure lock engagement.

EASY MOTOR RELEASE

Set DIP 11 to ON to enable easy manual release (provided that DIP 10 is ON), upon closing a reverse motion with a fixed time of 0.2 seconds occurs to facilitate manual release.

OPERATION OF SAFETY ACCESSORIES

PHOTOCELL (COM-PHOT)

DIP 4 OFF => if an obstacle is placed in range of the photocells when the gate is closed, the gate does not open. During operation, photocells work when opening (by starting the opening movement only after the obstacle is removed) and closing

(by starting the reverse movement only after the obstacle is removed).

DIP 4 ON => if an obstacle is placed in range of the photocells when the gate is closed and the command to open is given, the gate opens (the photocells do not work while opening). Photocells work only during closing (with reverse motion restored after a second, even if they are still engaged).

STEP-BY-STEP BUTTON (COM-K BUTTON)

If DIP 6 OFF => It cyclically performs the commands open-stop-close-stop-open etc.

If DIP 6 ON => Opens the gate when closed. There is no effect if activated while opening.

If activated when gate is open, the gate closes. If activated while closing, the gate reopens.

OPEN BUTTON (COM-OPEN)

The button controls the opening movement when the gate is stationary. If activated while closing, it reopens the gate.

CONTROL OF IMMEDIATE CLOSING AFTER MOVEMENT IN FRONT OF PHOTOCELLS

DIP 16 ON and DIP 4 OFF => if photocells are engaged during opening, the gate stops and the gate only closes one second after the photocells are disengaged.

DIP 16 ON and DIP 4 ON => if photocells are engaged during opening, the gate continues to open. Upon disengagement of the photocells, the gate stops and reverses closing motion after a one second pause.

If total opening is reached (end of opening time), immediate closing is deactivated and automatic time closing is activated (if TCA trimmer is activated and LED DL6 is on). If during closing there is a rapid movement (e.g. pedestrian) the gate will open again for two seconds and then close once again.

DIP 12 OFF => immediate closing after movement in front of the photocells is deactivated.

N.B.: Please check photocell operation at least every six months.

CLOCK FUNCTION OF OPEN BUTTON

If you want to apply a clock (or more simply a switch) to open and keep open the gate, you have to take T2 24V with fw 03 NOUP.

If fw 03 or higher ATTENTION: IN CASE OF FAILURE OF ONE SAFETY, ONE MINUTE

AFTER THAT CLOCK OR SWITCH HAVE BEEN ACTIVATED, THE GATE WILL OPEN

WITHOUT SAFETIES ACTIVE!

EDGE (SAFETY STRIP) (COM-EDGE)

If engaged during opening, reverses the motion when closing.

If engaged when closing, reverses the motion when opening.

If it remains engaged again, it performs a further reversal after 2 seconds, then performs an additional short reversal and then gives the sensor failure or engaged alarm (N.O. contact).

If the sensor remains engaged (N.O. contact) no movement is allowed.

If not used, jump the terminals COM-EDGE.

This function is useful during peak hours, when vehicle traffic is slow (e.g. entry/exit of workers, emergencies in parking or residential areas and, temporarily, for moving operations).

CLOCK FUNCTION APPLICATION

It is necessary to request a T2 24V control panel with firmware 02. By connecting a switch and/or a daily/weekly clock (instead of or in parallel to the open button N.O. “COM-

OPEN”), you can open and keep the automation open for as long as the switch is pressed or the clock remains active. Command functions are inoperative with open automation.

Releasing the switch or at the preset time, the automation closes immediately.

MONITORING OF SAFETY SENSORS (A+ TEST A-)

Sensors can be monitored through the A+ TEST input and DIP 12 ON.

The monitoring consists of a functional test of the sensor run after every full gate opening.

Closing the gate is therefore permitted only if the sensors have passed the functional test after each opening.

CAUTION: MONITORING OF THE SENSOR INPUT CAN BE ACTIVATED WITH DIP 12 ON OR

DEACTIVATED WITH DIP 12 OFF. IN FACT, THE FUNCTIONAL TESTING OF SENSORS IS

‘POSSIBLE ONLY IF THESE DEVICES HAVE THEIR OWN POWER SUPPLY.

A MECHANICAL SENSOR CAN NOT BE MONITORED, SO DIP 12 SHOULD BE SET TO OFF.

CLOSE BUTTON (COM-CLOSE)

Controls the closing movement when the gate is stationary.

REMOTE CONTROL

If DIP 6 OFF => It cyclically performs the commands open-stop-close-stop-open etc.

If DIP 6 ON => Opens the gate when closed. There is no effect if activated while opening.

If activated when gate is open, the gate closes. If activated while closing, the gate reopens.

PEDESTRIAN OPEN BUTTON (COM-PED.BUTT.)

Partial opening and closing control. During pedestrian opening, pausing or closing, you can control the opening of any command linked to the T2 24V board.

With DIP 6 you can choose the operation mode of the pedestrian push button.

If DIP 6 OFF => It cyclically performs the commands open-stop-close-stop-open etc.

If DIP 6 ON => Opens the gate when closed. There is no effect if activated while opening.

If activated when gate is open, the gate closes. If activated while closing, the gate reopens.

SENSOR AUTOTEST ALARM (DIP 12 ON)

If the sensor fails the monitoring test after opening, an alarm is displayed by the blinker lighting up. Gate closure is not allowed in this condition. Normal operation can be restored only by repairing the sensor and pressing one of the activated controls.

STOP BUTTON (COM-STOP)

The STOP button stops the gate during any operation.

If held when the gate is fully open (or partially when using the pedestrian control) automatic closing is temporarily deactivated (if activated by the TCA trimmer and LED DL6 on). It is therefore necessary to use a new command to make it close.

The automatic closing function is reactivated on the next cycle (if activated by the TCA trimmer and LED DL6 on).

34

POWER SENSOR ALARM

The T2 24V control panel has automatic sensors that make the movement of the gate reverse in case of impact against objects or persons in accordance with the current EN standards

(always use the right tool to ensure compliance with the values imposed by the standard), without special adjustments on the control panel, as it operates using special internal software. If the power sensor is used in opening or closing (only in high-speed) and then again, in the opposite direction, the gate stops and then reverses for 1 second.

The alarm status will be displayed by the blinker which will remain active for one minute, during which time you can restore gate operation by pressing any command button.

FUNCTIONING IN DEAD MAN MODE WHEN THE SAFETY DEVICES ARE FAILING

If the safety edge fails or remains engaged for more than 5 seconds, or if photocell fails or remain engaded for more than 60 seconds, the open, close, k button and pedestrian commands will work only in dead man mode.

The signal that this mode has been activated is given by the blinking of the programming led.

With the blinking of the programming led, the opening and closing operation are allowed only with the command button pressed and held. The radio commands and that of automatic closing, will be excluded, since their use in this mode, is not allowed by the norms.

Once the failing safety device is repaired, in automatic after 1 second, all standard commands that were selected, such as step by step, automatic mode, radio commands and automatic closing start functioning again.

Note 1: during this functioning in dead man mode, in case of damage to the safety strips

(or photocells) the photocells (or safety strips) still work by interrupting the operation in progress.

Note 2: the stop command is not to be considered a safety command that can be bypassed in this mode. Therefore, when pressed or damaged, it will not allow any movement of the gate.

The dead-man operation is only an emergency operation which must be activated for a very short period and with the complete installation at sight so to have a secure and safe control of the system. As soon as possible however, the failing safety devices must be repaired and activated.

BLINKER

N.B.: This control panel can power ONLY BLINKERS ON A (ACG7061) CIRCUIT with lamps up to 24V and 20W.

PRE-BLINKING

DIP 5 - OFF => the motor and blinker begin simultaneously.

DIP 5 - ON => the blinker begins 3 seconds before the motor.

GATE OPEN WARNING LIGHT (COM-SIGNAL)

Signals when the gate is open, partially open or not closed completely. Turns off only when the gate is completely closed. This signal is active during programming.

N.B.: Max 3 W. If push buttons or lamps are in excess, the control panel processes will be endangered and possibly halt operation.

OPERATION AFTER A BLACK-OUT (WITHOUT BATTERIES)

When the power supply comes back the DL1 led turns on and remains on for all the time the gate stays open. The led will turn off only once the gate is completely closed. It is recommended to fully open the gate. Let the gate close by itself or with automatic closing, or wait until the blinker stops flashing before commanding it to close.

This will allow the gate to realign. If, motors were released and moved from the normal position when closed during the blackout, the first movement after power returns must be complete.

If the black out occurs when the gate is still moving or when the gate is open and the first command sent after the black out is a closing command, the closing of the gate will be carried out with a total delay between the two gate leaves. Therefore, first the leaf M2 will close completely; once it is off, M1 will start closing. This separate movement of the two gate leaves is done to avoid their incorrect overlapping.

TECHNICAL SPECIFICATIONS

- Temperature range

- Humidity

- Voltage

- Frequency

- Battery power

- Transformer Power

- Maximum absorption

- Network Micro-switches

0 ÷ 55°C

<95% without condensation

230V~ ± 10% (120V/60Hz upon request)

50/60 Hz

20-24Vdc

130VA - primary 230Vac - secondary 18Vac

50 mA

100ms

- Maximum power gate open indicator 24Vdc 3W (equivalent to one 3W or 5 LED light bulb with resistor in series at 2.2 K ohm)

- Maximum blinker power 24Vdc 20W

- Power available for photocells and accessories 1A ± 15%

- Power available for radio connector 200mA

RADIO SPECIFICATIONS (model T2 24V CRX)

- Receiving Frequency

- Impedance

- Sensitivity

- Pick-up time

433,92 MHz

52 OHM

>2,24µV

300ms

- Drop time 300ms

- All inputs must be used as clean contacts because the power is generated internally (secure power) to the board and is set up to ensure compliance with double or reinforced insulation with regard to dangerous voltage.

- Any external circuits connected to the outputs of the control panel must be made in such a manner as to ensure compliance with double or reinforced insulation with regard to dangerous voltage.

- All inputs are controlled by a programmed integrated circuit that performs a self check every time it starts operating.

TROUBLE SHOOTING

After having carried out all connections, by carefully following the layout and having positioned the gate in intermediate position, check the correct ignition of red LEDS DL7, DL8 and DL9

In case of no ignition of the LEDS, always with gate in intermediate position, check the following and replace any faulty components.

DL7 switched OFF Faulty photocells

DL8 switched OFF jumper between COM and EDGE)

Stop button malfunction (if Stop is not connected, perform the jump between COM and STOP).

During functioning with personnel present, with DIP 1 at ON, check that during opening of

M1 and M2 the green DL2 and DL4 LEDS switch on and that during closing of M1 and M2 the red DL3 and DL5 LEDS switch on.

Or else, reverse the wires of the motor.

FAULT SOLUTION

After having carried out the various connections and having supplied voltage, all the LEDS are switched off.

Check fuses F1, FUSE 1.

If the fuse is blown, use only a suitable replacement.

F1 T 2A TRANSFORMER PROTECTION FUSE (on the outside of the T2 24V board)

FUSE 1 8A MOTOR PROTECTION FUSE

The motor opens and closes, but it has no strength and moves slowly.

Check trimmers RUN and LOW-SPEED adjustment.

The gate opens but does not close after the time set.

The gate does not open or close by activating the various K, Radio, Open and Close buttons.

The electric lock does not work.

LED DL1 blinks rapidly and no movement is activated.

Make sure that the TCA trimmer is activated with LED DL6 on.

OPEN button always on, replace the OPEN control button or switch.

Sensor Auto test failed, check the connections between the control panel and the sensor power supply.

Warning: If you are not using a power supply for the sensors, DIP 12 should be OFF.

Faulty safety edge contact. Faulty photocells contact with DIP 4 OFF.

Fix or replace the relative contact.

Ensure to have enabled DIP 8 at ON.

Place dip switches 1, 2 or 3 in the OFF position.

35

G

B

G

B

ACCESSORIES

For the connections and the technical data of the optional equipments follow the relevant handbooks.

RADIO TRANSMITTER SUN

SUN 2CH code ACG6052

SUN CLONE 2CH code ACG6056

SUN 4CH code ACG6054

SUN CLONE 4CH code ACG6058

BATTERY CHARGER CARD BATTERY

code ACG4648 Battery 2,2Ah 12V

Wi-Fi DEVICES

MASTER Wi-Fi

code ACG9515

RECEIVER CARD TO MANAGE WIRELESS SYSTEM with connector - 12÷30V ac/dc with terminal block - 12÷30V ac/dc

NOVA Wi-Fi

code ACG6094 code ACG6099

VERTIGO Wi-Fi

PHOTOCELLS WITHOUT WIRES

PAIR OF COLUMS NOVA

BLOCK Wi-Fi

code ACG8037 code ACG8039

WIRELESS PHOTOCELLS SUBSTITUTING THE SAFETY STRIP

VERTIGO Wi-Fi 8 code ACG8042 - VERTIGO Wi-Fi 10 code ACG8043

SPARK Wi-Fi

KEY SELECTOR WITHOUT WIRES code ACG6098

36

BLINKER WITHOUT WIRES

LATERAL SUPPORT code ACG7064 code ACG7042

2

ANLAGEN LAY-OUT

5 1

1 - E-Torantrieb PRINCE

2 - Antenne

3 - Blinkleuchte

4 - Schluesselschalter

5 - Photozelle Toraussenseitig

1 5 4

3

4

1

TECHNISCHE EIGENSCHAFTEN

PRINCE ist eine Antriebe die für Drehtore mit den Torflügen bis zu 3 m und 250 kg verwendbar sind (Abb. 1).

PRINCE benutzen eingebaute mechanische Stopper und so ist es nicht

Notwendig einen elekrtrischen Endschalter zu installieren.

NOTIZ: Wenn Sie einen Prince installieren empfehlen wir ihnen ein elektrisches Schloss zur sicheren Verrieglung zu installieren.

TECHNISCHE EIGENSCHAFTEN

Max. Torflügelweite

Max. Torgewicht

Max. Hub

Mittlere Öffnungszeit zirka

Laufgeschwindigkeit

Stromspannung und frequenz

Motorleistung

Max. Motorleistung

Stromaufnahme

Max. Stromaufnahme

Schubkraft

Max. Schubkraft

Normative Zyklen

Zyklen rieten einem Tag

Service

Garantierte nachfolgende Zyklen

Motorgewicht

Geräusch

Betriebstemperatur

Schutzart m kg mm s.

m/s

°C

IP kg db n°

% n°

N n°

A

N

W

W

A anspricht. Wird auch der optionale mechanische Anschlag benutzt, der während des Schließens anspricht, so reduziert sich der maximale Zughub um 30 mm.

PRINCE 24V

3

250

343**

14

0,0134

24Vdc

12

89

0,88

3,72

1000

1500

∞ - 14s/2s

60

80

60/14s

5

<70

-30 ÷ +55°C

44

D

Abmessungen in mm

2

37

D

INSTALLATION PRINCE

PRÜFUNG VON DER MONTAGE

Das Flugeltor muß fest an der Angelpunkten der Träger fixiert sein, darf sich während der

Bewegung nicht biegen und ohne Reibung bewegen.

Bevor PRINCE montiert wird ist es besser alle Hindernisse, die bei der Montage auftreten können festzustellen.

Bei einem Tor wie in Abbildung 1 müssen keine Veränderungen vorgenommen werden.

ANMERKUNG: Es ist erforderlich, die Charakteristiken des Tors an die geltenden Normen und

Gesetze anzupassen. Das Tor kann nur automatisch Angeschlossen werden, wenn es in einem einwandfreien Zustand ist und der EN12604 entspricht.

- Das Tor welches keine Gehfluegelfunktion hat,in diesem Fall ist es erforderlich das Tor mit der norm EN12453 in Einklang zu bringen(z.B. das in Bewegung setzen des Motors per Handsender, wenn der Gehfluegel geoeffnet ist. Das zu vehindern koennen sie einen

Endschalter anschliessen der beim oeffnen des Gehfluegel andere automatischen funktionen ausser Kraft setzt).

Komponenten zur Installation nach der Norm EN1253

ANWENDUNG DER SCHLIESSUNG

STEUERUNGSSYSTEM

mit Totmannschaltung

Fachpersonen

(außer einem

öffentlichen Platz*)

A

Fachpersonen

(öffentlicher Platz)

B

Grenzlose

Anwendung nicht möglich mit sichtbaren

(z.B. Sensor) mit nicht sichtbaren

Impulsen (Fernsender) automatisch

C oder E

C oder E

C und D, oder E

C oder E

C und D, oder E

C und D, oder E

C und D, oder E

C und D, oder E

C und D, oder E

* ein Musterbeispiel dafür sind jene Türe, die keine Zufahrt zu einem öffentlichen Weg haben

A: Betriebstaste mit Totmannschaltung (das heißt, aktivieren sie eine Funktion, solange man sie gedrückt hält), wie Kode ACG2013

B: Schlüsselselektor mit Totmannschaltung, wie Kode ACG1010

C: Justierbare Kraft des Motors

D: Kontaktleiste und /oder andere Sicherheitseinrichtungen muessen mit den Norm

EN12453 uebereinstimmen (Anhang A).

E: Photozelle, wie Kode ACG8026 (Jede 60÷70 cm für die ganze Höhe der Spalte des

Gatters bis zu einem Maximum von 2,5 m anwenden - EN 12445 Punkt 7.3.2.1)

NOTENTRIEGELUNG

Um das Tor des Modells PRINCE manuell zu bedienen, müßen Sie den dafür vorgesehenen

Schluessel in das Schloß stecken und ihn 90° entgegen dem Uhrzeigersinn drehen (Abb. 3).

Um das Tor manuell richtig zu pruefen muessen folgende Punkte beachtet werden:

- Das Tor muss einen geeigneten Griff haben.

- Dieser Griff muss so angebracht sein das er kein Risiko ist beim Test.

- Daß die physische notwendige Kraft um das Tor-Blatt zu bewegen nicht höher als 225N ist, für Tore bei privaten Wohnungen, und 390N für Tore für kommerzielle und industrielle

Situationen (Werte nach 5.3.5 vom EN 12453 Norm).

BEFESTIGUNG DES ANTRIEBES AN DER SÄULE

Um PRINCE zu montieren, müssen einige Maße beachtet werden, damit eine richtige

Bewegung des Torflügels gegeben ist (Abb. 4, 5, 7, 8, 9)

Falls der Torträger aus Eisen ist, kann man die Verankerung direkt anschweißen.

Bei einem Torträger aus Zement bedient man sich einer Platte wie in Abb. 4, die man mit 4

Fischer-Dübel Ø 8 mm anschraubt.

Im Falle, es existiert eine Maurer, die parallel zum Tor im offenen Zustand läuft, ist es notwendig eine Wandvertiefung zu schaffen, um Platz für den Motorantrieb zu haben.

BEFESTIGUNG DES ANTRIEBES AUF DAS TORFÜGEL

Schweißen Sie den Sockel in der richtigen Höhe (Abb. 6-9) an.

Befestigen Sie PRINCE und versuchen Sie mehrere Male zu öffnen und zu schließen,

Kontrollieren Sie dabei, daß das Profil der Schraubenabdeckung das Tor in Bewegung nicht berührt.

38

3

4

5

sorgfältig einfetten

6

JA !

Achten Sie darauf, die Schraube, die die

Halterung hält an den

Betreiber, so dass es sich frei drehen kann anziehen.

7

NEIN !

Der Betreiber muss seine Höhe während der

Bewegung nicht ändern.

8

S1

Z

Y

X

Beachten Sie die Maßnahme und stellen Sie sicher, dass der

Betreiber ist horizontal

S2

Z

Y

X

COL

Halterung Pfeiler

Z

Y

X

S3

Die korrekten Abmessungen und Installation mit einem Stopper im Antrieb

L

Min.÷Max

1÷3 a

A max

B C D E

T sec

COL ANT

90°

0 100 100 765 90 13,5 S2-X A

20 100 100 765 90 13,5

S2-Y A

40 100 100 765 90 13,5 S3-X A

60 110 100 765 90 14 S3-Y A

80 140 110 765 115 17 S3-X B

100 160 110 765 115 18

S3-X B

120 180 110 765 115 19,5 S3-X B

140 210 110 765 115 21,5 S1-Z B

150 220 120 765 115 23 S1-Z B

110°

20 110 140 765 90 17

S1-Y A

Für eine korrekte Installation MIT ZWEI MECHANISCHE SPERRVORRICHTUNG

L

Min.÷Max

1÷3 a

A max

B C D E

T sec

COL ANT

0 100 100 730 90 13,5 S2-X A

20 100 100 730 90 13,5

S2-X A

40 100 100 730 90 13,5 S3-X A

60 110 100 730 90 14 S3-X A

90°

80 140 110 730 115 17 S3-X B

100 160 110 730 115 18

S3-X B

110 180 120 730 115 20 S1-Z B

110°

20 100 140 730 90 16 S2-Y A

ANT

Halterung Torfluegel

A

B

Falls der Torantrieb nicht mit dem richtigen Maß (B) montiert werden kann, da der Torträger zu breit ist, muß man in der Säule eine

Wandvertiefung schaffen oder das Tor an den Rand versetzen.

9

39

D

D

M

ECHANISCHE SPERRVORRICHTUNG - OPTIONEN

(Kode ACG8088)

Als Zubehör eine mechanische Sperrvorrichtung, die das Gittertor beim Schließen anhält, falls keine Feststellvorrichtung auf dem Boden vorhanden ist.

E

INSTELLUNG DES MECHANISCHEN ENDSCHALTERS

Um die Endschalter einzustellen, müssen Sie wie in der Abbildung handeln (Abb. 11).

Um die erwünschte Offnungsweite einzustellen, genüngt es, die Endschalter (A) zu verstellen und sie mit Hilfe eines Imbusschlüßels an der Mutterschraube festzuziehen. Um die erwünschte

Schliessweite einzustellen, müssen Sie die Endschalter (B) verstellen.

W

ARTUNG

Die Wartungsarbeit nur durch spezialiesierten Fachleuten nach der Ausschliessung der

Spannung auszuführen.

Einmal jährlich sind die Angelzapfen zu schmieren und die vom Getriebemotor ausgeübte

Antriebskraft.

Es wird empfohlen, alle zwei Jahre die Schnecke mit Silikonfett zu schmieren.

ELEKTROANSCHLÖÜSSE

A B

C

40

D

10

11

T2 24V Kode AC07088

T2 24V CRX Kode AC07089

24Vdc 0,8A ± 15% für ZUBEHÖRE

24Vdc 0,8A ± 15% für AUTOTEST KONTAKTLEISTE

BLINKER

24Vdc 20W

FUSSGÄNGER

EINZELIMPULS

FOTOZELLEN

GEMEINSAME ERDUNGSKONTAKTE

KONTAKLEISTE

LED

R=2,2K 1/4W

GEMEINSAME

ERDUNGSKONTAKTE

ANTENNE

SCHLIEßEN

ÖFFNEN

STOPPSCHALTER

ANTENNE

Zopfflechten

ELEKTROSCHLOSS

STROMVERSORGUNG

230Vac 50 Hz

SICHERUNG

T 2 A

TRANSFORMATOR

D

M1

M2

41

D

J1

J2

J3

J4

J5

J6

J7

J8

J9

J10

TR1

TR2

TR3

N F

COM.

CLOSE

OPEN

STOP

AERIAL

SIGNAL

A+TEST

EDGE N.C.

COM.

PHOTO N.C.

K BUTT.

PED. BUTT.

A+

A -

LOCK

SECONDARY

TRANSFORMER

MOTOR 1

MOTOR 2

SW T2 24V

SW RADIO

RADIO

BATTERY

CHARGER

TRIMMER RUN

TRIMMER LOW

SPEED

TRIMMER TCA

Speisung 230 Vac 50/60 Hz - extern an der Karte -

(120V/60Hz auf Anfrage)

Gemeinsame erdungskontakte

Schließung-Impuls-Kontakt (NA)

Öffnungs-Impuls-Kontakt (NA)

Stop-Impuls-Kontakt (NC)

Radio Antenne

Kontrollanzeigelampe Tor offen, signalisiert den Batterie betriebenen Funktionierungsstand und leere Batterie (24Vdc

3W max)

Positive Ladung für die Speisung für Rippen Selbstkontrolle

Ripppen-Kontakt (NC)

Gemeinsame Erdungskontakte

Fotozellen-Kontakt (NC)

Einzel-Impuls-Kontakt (NA)

Kontakt Befehl Öffnung für den Fußgängerdurchgang (NA)

Positive Ladung für die Speisung für Rippen Selbstkontrolle

Negative Ladung für die Speisung der Zubehöre zu 24Vdc

Anschluss zu Elektroschloss-Riegelung (MAX 15W 12V)

Anschluss zu Blinker Negativ-Fase zu 24Vdc (Kode

ACG7061) auf die Polarität achten.

Verbinder für Sekundär Transformator 18 Vac

A - VERBINDUNGEN

J9

J10

J8

Verbindung MOTOR 1 (ohne Polarität)

Verbindung MOTOR 2 (ohne Polarität)

Verbinder für die Programmierung in der Fabrik. NICHT

DIE ÜBERBRÜCKUNG BERÜHREN ! OHNE ANTRIEB NICHT

BETRIEBSFÄHIG!

Verbinder für die Programmierung in der Fabrik (nur für die

Modelle CRX). NICHT DIE ÜBERBRÜCKUNG BERÜHREN !

OHNE ANTRIEB NICHT BETRIEBSFÄHIG!

Radio-Modul eingebaut (Modell CRX), oder Verbinder für

Radioempfänger RIB Steckverbindung mit Speisung zu

24Vdc

Verbinder für Batterie-Aufladekarte zu 24Vdc (Kode

ACG4648)

Trimmer elektronischer Regler für hohe Geschwindigkeit

Trimmer langsamlaufregler nur bei Schließung

Trimmer automatische schliessung vollständig oder

Teilweise - Standardeinstellung: NICHT ZUGELASSEN und

LED DL6 AUSGESCHALTET

J7

S3

S3 PROG

FUSE 1 T 8 A

F1 T 2 A

J2 J3

J1

TR1

Programmierungs-Schaltknopftaste

Sicherung Motorschutz

Sicherung Transformatorschutz

TR2

F1

TRANSFORMER

J4

FUSE 1

J5

J6

TR3

B - EINSTELLUNGEN

DIP 1 (ON) - STEUERUNG MOTORDREHRICHTUNG (PUNKT C)

DIP 2 (ON) - ZEITPROGRAMMIERUNG (PUNKT D)

DIP 3 (ON) - FLÜGELFREIGABE WÄHREND DER LAUFVERLANG-SAMUNG, UND AUCH

BEI VOLLSTÄNDIGER ÖFFNUNG UND SCHLIESSUNG (IM HINBLICK AUF DIE

ANSCHLAGPROBEN LAUT EN12453)

DIP 1-2 SPEICHERUNG/LÖSCHEN DER FUNKCODES FÜR BEFEHL VOLLSTÄNDIGES

SCHLIESSEN (NUR MODELL CRX) (PUNKT E)

DIP 1-3 SPEICHERUNG/LÖSCHEN DER FUNKCODES FÜR BEFEHL FUSSGÄNGER-

ÖFFNUNG (NUR MODELL CRX) (PUNKT F)

DIP 2-1 ZEITPROGRAMMIERUNG FUSSGÄNGER - ÖFFNUNG BETRIEBS-

MIKROSCHALTER

DIP 4 Fotozellen immer aktiv (OFF) - Fotozellen nur bei Schließung aktiv (ON)

DIP 5 Vorblinken (ON) - Normales Blinken (OFF)

DIP 6 Befehl Einzelimpuls (K BUTT) und eingebautes Radiogerät Schritteinzelbefehl (OFF)

- automatisch (ON)

DIP 7 Funktionsweise mit Stromsensoren (ON-aktiviert) Funktion auf Zeit (OFF-aktiviert).

DIP 8 Freigabe elektrische Verriegelung (ON-aktiviert)

DIP 9 Freigabe Rückschlag elektrische Verriegelung (ON-aktiviert)

DIP 10 Freigabe Rückschlag elektrische Verriegelung (ON-aktiviert)

DIP 11 Freigabe Erleichterte Entblockung (ON-aktiviert)

DIP 12 Freigabe TEST Selbstkontrolle der Kontaktleiste (ON-aktiviert).

DIP 13 Wahlweiser Betrieb mit 1 oder 2 Motoren (Standardeinstellung: OFF 2 Motoren)

DIP 14 OFF

DIP 15 OFF

DIP 16 SOFORT-SCHLIESSUNG NACH DEM PASSIEREN DER FOTOZELLEN

EIN AKTIVIERT

AUS DESAKTIVIERT

JP1 => Überbrückung muss angewählt sein!

JP2 => Überbrückung muss angewählt sein!

JP3 => Überbrückung muss angewählt sein!

PROG => S3 Programmierschalter

E

INSTELLUNGEN

ACHTUNG: AKTIVIEREN DAS DIP 3 NÜR NACH ALLE DIE PROGRAMMIERUNGEN.

ZU BEACHTEN: MIT DIP 3 (ON) WIRD DIE FUNKTION DER KURZFRISTIGEN

FLÜGELUMKEHR NACH DEM ANSCHLAG AKTIVIERT.

DIESE KURZFRISTIGE FLÜGELUMKEHR REDUZIERT DIE STATISCHE KRAFT

INNERHALB VON 5 SEKUNDEN AUF NULL LAUT PUNKT A.2.2 DER NORM EN12453

(BETRIEBSKRÄFTE) UND ERLAUBT SOMIT DIE EINHALTUNG DER ANSCHLAGPROBEN

LAUT DERSELBEN NORM EN12453. SOLLTE KEINE NOTWENDIGKEIT BESTEHEN, DER

OBEN BESCHRIEBENEN NORM NACHZUKOMMEN, REICHT ES AUS, DIP 3 AUF AUS ZU

STELLEN. IN DIESEM FALL SCHLIESSEN SICH DIE FLÜGEL, OHNE DIE BEWEGUNG ZU

INVERTIEREN.

TRIMMER RUN (TR1) Elektronischer Regler für hohe Geschwindigkeit

Mit diesem Trimmer kann die Motorgeschwindigkeit eingestellt werden (Standardeinstellung:

42

Höchstgeschwindigkeit). Diese Regulierbarkeit ist von Nutzen, um die Automatik mit den

Europäischen Normen im Bezug auf den Anschlag konform zu gestalten.

TRIMMER LOW SPEED (TR2) Langsamlaufregler nur bei Schließung

Die Einstellung des Langsamlaufes erfolgt über den Trimmer LOW SPEED durch

Spannungsregulierung der Motoren (im Uhrzeigersinn drehend wird die Geschwindigkeit erhöht). Diese Einstellung reguliert die korrekte Geschwindigkeit am Ende der Öffnung und der Schließung je nach Torstruktur oder beim Auftreten von leichter Reibung, die die korrekte

Funktionsweise des Systems beeinträchtigen könnten.

TRIMMER AUTOMATISCHE SCHLIESSUNG TCA (TR3) VOLLSTÄNDIG ODER TEILWEISE

(FUSSGÄNGER-ÖFFNUNG) Standardeinstellung: NICHT ZUGELASSEN und LED DL6

AUSGESCHALTET (TRIMMER VOLLSTÄNDIG IM UHRZEIGERSINN GEDREHT)

Dieser Trimmer erlaubt die Zeiteinstellung vor der automatischen Schließung sowohl teilweise als auch vollständig. Funktioniert nur bei kompletter vollständigere oder teilweiser (Fußgänger-

Öffnung) Öffnung und eingeschalteter LED-Anzeige DL6 (Trimmer im Uhrzeigersinn gedreht).

Die Pause kann von mindestens 2 Sekunden bis maximal 2 Minuten eingestellt werden.

LED-ANZEIGEN

DL1 Programmierung aktiviert (Rot)

DL2 Tor in Öffnung M2 (Grün)

DL3 Tor in Schließung M2 (Rot)

DL4 Tor in Öffnung M1 (Grün)

DL5 Tor in Schließung M1 (Rot)

DL6 Zeitangabe automatische Schließung (Rot)

DL7 Kontakt Fotozellen (NC) (Rot)

DL8 Kontakt Kontaktleiste (NC) (Rot)

DL9 Befehl STOPP (NC) (Rot)

DL10 Programmierung Funkcodes (Grün)

SICHERUNGEN

Fuse 1 T 8A SICHERUNG MOTORSCHUTZ

F1 T 2A SICHERUNG TRANSFORMATORSCHUTZ (außerhalb des Steckverbinders T2

24V)

C - STEUERUNG MOTORDREHRICHTUNG

1 - DIP 1 auf ON stellen=> Die LED-AnzeigeDL1 beginnt zu blinken.

2 - Den Schalter PROG. drücken und gedrückt halten (die Bewegungen Öffnen-Stopp-

Schließen-Stopp-Öffnen-usw. werden vom Steuerpult aus bedient) => DIE GRÜNEN

LED-ANZEIGEN DL2 und DL4 leuchten auf und die Flügel öffnen sich mit fixer

Phasenverschiebung von 2 Sekunden. Schließen sie sich hingegen statt sich zu öffnen, den Schalter loslassen und die beiden Anschlüsse des betreffenden Motors invertieren.

3 - Nach der vollständigen Öffnung den Schalter PROG. loslassen und das Tarieren der

Öffnungs-Endanschläge vornehmen (am Bedienelement).

4 - Den Schalter PROG. drücken und gedrückt halten => DIE ROTEN LED-ANZEIGEROSSI

DL3 und DL5 leuchten auf und die Flügel schließen sich mit fixer Phasenverschiebung von 2 Sekunden

5 - Den Schalter PROG bis zur vollständigen Schließung des Tors gedrückt halten.

6 - Zur Zeitprogrammierung beide Flügel vollständig geschlossen halten.

7 - DIP1 wieder auf OFF stellen => Die LED-AnzeigeDL1 erlischt und zeigt das Ende der

Kontrolle an.

ZU BEACHTEN. Während dieser Kontrolle sind der Stopp, die Fotozellen und die

Kontaktleisten nicht aktiv.

D - ZEITPROGRAMMIERUNG BEI 2 MOTOREN (#)

MIT AKTIVIERTEM STROMSENSOR (DIP 7 ON)

WÄHREND DER PROGRAMMIERUNG BLEIBT DER STROMSENSOR IMMER AKTIV:

1 - Das Tor muss vollständig geschlossen sein.

2 - DIP 2 auf ON stellen=> Die LED-AnzeigeDL1 beginnt zu blinken.

3 - Den Schalter PROG. drücken=> M1 öffnet.

4 - Nach Erreichen des Öffnungs-Endanschlages, hält der AUTOMATISCHE STROMSENSOR

M1 an (und speichert Zeit und Stromwerte) => Gleichzeitig aktiviert sich M2 und öffnet.

5 - Nach Erreichen des Öffnungs-Endanschlages, hält der AUTOMATISCHE STROMSENSOR

M2 an (und speichert Zeit und Stromwerte)

6 - Den Schalter PROG. drücken=> M2 schließt.

7 - Den Schalter PROG. drücken => M1 schließt und bestimmt die Phasenverschiebung zwischen M2 und M1. Gleichzeitig erlischt die LED-Anzeige DL1 und zeigt das Ende der

Speicherprozedur an.

Ab diesem Zeitpunkt funktionieren die Sicherheitsbefehle des Tor normal (Umkehr, Stopp,

Alarmfunktionen, usw....).

8 - Die Schließung der Flügel erfolgt mit hoher Geschwindigkeit (je nach Einstellung des

Trimmers RUN) und mit Laufverlangsamung gegen Ende der vollständigen Schließung (je nach Einstellung des Trimmers LOW SPEED).

9 - Bei Erreichen der vollständigen Schließung halten die Sensoren das Tor an.

10 - NACH BEENDIGUNG DER PROGRAMMIERUNG DIP 2 AUF OFF STELLEN.

D - ZEITPROGRAMMIERUNG BEI 1 MOTOR (M1) (#)

MIT AKTIVIERTEM STROMSENSOR (DIP 7 ON)

ACHTUNG: BEI NUR EINEM MOTOR MUSS DIP 13 AUF GESTELLT WERDEN ON

WÄHREND DER PROGRAMMIERUNG BLEIBT DER STROMSENSOR IMMER AKTIV.

Das Tor muss vollständig geschlossen sein.

1 - DIP 2 auf EIN stellen=> Die LED-AnzeigeDL1 beginnt zu blinken.

2 - Den Schalter PROG. drücken=> M1 öffnet.

Nach Erreichen des Öffnungs-Endanschlages, hält der AUTOMATISCHE STROMSENSOR

M1 an (und speichert Zeit und Stromwerte).

3 - Den Schalter PROG. drücken => M1 schließt.

Gleichzeitig erlischt die LED-AnzeigeDL1 und zeigt das Ende der Speicherprozedur an.

Ab diesem Zeitpunkt funktionieren die Sicherheitsbefehle des Tor normal (Umkehr, Stopp,

Alarmfunktionen, usw....).

Bei Erreichen der vollständigen Schließung halten die Sensoren das Tor an.

4 - NACH BEENDIGUNG DER PROGRAMMIERUNG DIP 2 AUF OFF STELLEN.

(#) WÄHREND DER PROGRAMMIERUNG BLEIBEN DIE SICHERHEITSBEFEHLE AKTIV

UND IHR EINGREIFEN FÜHRT ZUM ANHALTEN DER PROGRAMMIERUNG (DIE LED-

ANZEIGEDL1 BLINKT NICHT MEHR, SONDERN BLEIBT ERLEUCHTET). UM MIT DER

PROGRAMMIERUNG FORTZUFAHREN, DIP 2 AUF AUS STELLEN, DAS TOR ÜBER

DEN VORGANG “STEUERUNG MOTORDREHRICHTUNG” SCHLIESSEN UND DIE

PROGRAMMIERUNG WIEDERHOLEN.

D - ZEITPROGRAMMIERUNG BEI 2 MOTOREN (#) AUF ZEIT (DIP 7 OFF)

1 - Das Tor muss vollständig geschlossen sein.

2 - DIP 2 auf ON stellen=> Die LED-AnzeigeDL1 beginnt zu blinken.

3 - Den Schalter PROG. drücken=> M1 öffnet.

4 - 1 Sekunde nach Erreichen des Öffnungs-Endanschlages, den Schalter PROG. drücken=>

M1 schließt und M2 öffnet.

5 - 1 Sekunde nach Erreichen des Öffnungs-Endanschlages, den Schalter PROG. drücken

=> M2 schließt.

6 - Den Schalter PROG. drücken. => M2 schließt.

7 - Den Schalter PROG. drücken => M1 schließt und bestimmt die Phasenverschiebung zwischen M2 und M1

Gleichzeitig erlischt die LED-AnzeigeDL1 und zeigt das Ende der Speicherprozedur an.

Ab diesem Zeitpunkt funktionieren die Sicherheitsbefehle des Tor normal (Umkehr, Stopp,

Alarmfunktionen, usw...).

8 - Nach der Zeitbestimmung schließt das Tor

9 - NACH BEENDIGUNG DER PROGRAMMIERUNG DIP 2 AUF OFF STELLEN.

ANMERKUNG: Die Laufverlangsamung wird automatisch durch die Steuerung während der Zeitprogrammierung bestimmt und wird etwa 50÷60 cm vor dem Öffnungs- oder

Schließungs-Endanschlag aktiviert.

D - ZEITPROGRAMMIERUNG BEI 1 MOTOR (#) AUF ZEIT (DIP 7 OFF)

ACHTUNG: BEI NUR EINEM MOTOR MUSS DIP 13 AUF GESTELLT WERDEN EIN

1 - Das Tor muss vollständig geschlossen sein.

2 - DIP 2 auf ON stellen=> Die LED-AnzeigeDL1 beginnt zu blinken.

3 - Den Schalter PROG. drücken => M1 öffnet.

4 - 1 Sekunde nach Erreichen des Öffnungs-Endanschlages, den Schalter PROG. drücken=>

M1 schließt.

5 - Den Schalter PROG. drücken => M1 schließt.

Gleichzeitig erlischt die LED-AnzeigeDL1 und zeigt das Ende der Speicherprozedur an.

Ab diesem Zeitpunkt funktionieren die Sicherheitsbefehle des Tor normal (Umkehr, Stopp,

Alarmfunktionen, usw....).

6 - Nach der Zeitbestimmung schließt das Tor.

7 - NACH BEENDIGUNG DER PROGRAMMIERUNG DIP 2 AUF OFF STELLEN.

D - PROGRAMMIERUNG ÖFFNUNGSZEITEN FUSSGÄNGER-ÖFFNUNG (#)

SOWOHL AUF ZEIT ALS AUCH MIT AKTIVIERTEM STROMSENSOR

Bei geschlossenem Tor:

1 - DIP2 auf ON schalten (Die LED-AnzeigeDL1 blinkt rasch) und dann DIP1 auf ON stellen

(Die LED-AnzeigeDL1 blinkt langsam).

2 - Den Fußgängerschalter drücken (COM-PED.BUTT) => M1 öffnet.

3 - Den Fußgängerschalter drücken um das Tor anzuhalten (auf diese Weise wird die Öffnung von M1 bestimmt).

4 - Den Fußgängerschalter drücken um das Tor zu schließen.

5 - Ist das Tor geschlossen DIP1 und 2 auf OFF stellen.

(#) WÄHREND DER PROGRAMMIERUNG BLEIBEN DIE SICHERHEITSBEFEHLE AKTIV

UND IHR EINGREIFEN FÜHRT ZUM ANHALTEN DER PROGRAMMIERUNG (DIE LED-

ANZEIGEDL1 BLINKT NICHT MEHR, SONDERN BLEIBT ERLEUCHTET). UM MIT DER

PROGRAMMIERUNG FORTZUFAHREN, DIP 2 AUF OFF STELLEN, DAS TOR ÜBER

DEN VORGANG “STEUERUNG MOTORDREHRICHTUNG” SCHLIESSEN UND DIE

PROGRAMMIERUNG WIEDERHOLEN.

E - PROGRAMMIERUNG FUNKCODES VOLLSTÄNDIGE ÖFFNUNG

(MAX. 62 CODES - NUR MODELLE CRX)

Die Programmierung erfolgt nur bei geschlossenem Tor.

1 - DIP 1 auf ON und anschließend DIP 2 auf ON stellen.

2 - Die rote LED-AnzeigeDL1 für die Programmierung blinkt mit einer Frequenz von 1 Sek.

ON und 1 Sek. OFF für 10 Sekunden.

3 - Die Fernsteuerungs-Taste (normalerweise Kanal A) innerhalb der vorgeschirebenen Zeit von 10 Sekunden drücken. Wenn die Fernsteuerung korrekt programmiert worden ist, blinkt die LED-Anzeige DL10 (Grün).

Die Programmierzeit der Codes verlängert sich automatisch, damit die nächste

Fernbedienung programmiert werden kann. .

43

D

D

5 - Um die Programmierung abzuschließen, 10 Sekunden warten oder die Taste PROG drücken. Die rote LED-Anzeige erlischt.

6 - Erneut DIP 1 und DIP 2 auf OFF stellen.

7 - Ende des Programmiervorgangs.

VORGEHEN ZUR VOLLSTÄNDIGEN LÖSCHUNG DER FUNKCODES FÜR VOLLSTÄNDIGE

ÖFFNUNG

Die Löschung kann nur bei geschlossenem Tor erfolgen.

1 - DIP 1 auf ON und anschließend DIP 2 auf ON stellen.

2 - Die rote LED-Anzeige DL1 für die Programmierung blinkt mit einer Frequenz von 1 Sek.

ON und 1 Sek. OFF 10 Sekunden lang.

3 - Die Taste PROG 5 Sekunden lang gedrückt halten. Die Löschung des Speichers wird durch zweimaliges Blinken der grünen LED-Anzeige DL10 angezeigt.

4 - Die rote LED-Anzeige DL1 bleibt für die Programmierung aktiv und es ist jetzt möglich, neue Codes wie oben beschrieben einzugeben.

5 - Erneut DIP 1 und DIP 2 auf OFF stellen.

6 - Ende des Programmiervorgangs.

ANZEIGE “SPEICHERKAPAZITÄT ERSCHÖPFT” FÜR DIE VOLLSTÄNDIGE ÖFFNUNG

Diese Anzeige erhält man nur bei geschlossenem Tor.

1 - DIP 1 auf EIN und anschließend DIP 2 auf EIN stellen.

2 - Die grüne LED-Anzeige DL10 blinkt 6mal und zeigt den vollen Speicher an (62 vorhandene Codes).

3 - Anschließend bleibt die LED-Anzeige DL1 10 Sekunden für die Programmierung aktiv und erlaubt somit die vollständige Löschung aller Codes.

4 - Erneut DIP 1 und DIP 2 auf AUS stellen.

5 - Ende des Vorgangs.

F - PROGRAMMIERUNG FUNKCODES FÜR DIE FUSSGÄNGER-ÖFFNUNG

(MAX.

62 CODES - NUR MODELLE CRX)

Die Programmierung erfolgt nur bei geschlossenem Tor.

1 - DIP 1 auf ON und anschließend DIP 2 auf ON stellen.

2 - Die rote LED-Anzeige DL1 für die Programmierung blinkt mit einer Frequenz von 1 s ON und 1 s OFF 10 Sekunden lang.

3 - Die Fernsteuerungs-Taste (normalerweise Kanal B) innerhalb der vorgeschriebenen Zeit von 10 Sekunden drücken. Wenn die Fernsteuerung korrekt programmiert worden ist, blinkt die LED-Anzeige DL10 (Grün).

Die Programmierzeit der Codes verlängert sich automatisch, damit die nächste

Fernbedienung programmiert werden kann.

5 - Um die Programmierung abzuschließen, 10 Sekunden abwarten oder die Taste PROG drücken. Die rote LED-Anzeige erlischt.

6 - Erneut DIP 1 und DIP 2 auf OFF stellen.

ANMERKUNG: WENN DIE LED-ANZEIGE DL1 STÄNDIG RASCH WEITERBLINKT,

BEDEUTET DAS, DASS DIP 1 NOCH AUF ON STEHT UND JEDER WEITERE VORGANG

UNMÖGLICH IST.

7 - Ende des Programmiervorgangs.

VORGEHEN ZUR VOLLSTÄNDIGEN LÖSCHUNG DER FUNKCODES FÜR FUSSGÄNGER-

ÖFFNUNG

Die Löschung kann nur bei geschlossenem Tor erfolgen.

1 - DIP 1 auf ON und anschließend DIP 2 auf ON stellen.

2 - Die rote LED-Anzeige DL1 für die Programmierung blinkt mit einer Frequenz von 1 s ON und 1 s OFF 10 Sekunden lang.

3 - Die Taste PROG. 5 Sekunden lang gedrückt halten. Die Löschung des Speichers wird durch zweimaliges Blinken der grünen LED-Anzeige DL10 angezeigt.

4 - Die rote LED-Anzeige DL1 bleibt für die Programmierung aktiv und es ist jetzt möglich, neue Codes wie oben beschrieben einzugeben.

5 - Erneut DIP 1 und DIP 2 auf OFF stellen.

6 - Ende des Programmiervorgangs.

ANZEIGE “SPEICHERKAPAZITÄT ERSCHÖPFT” FÜR DIE FUSSGÄNGER-ÖFFNUNG

Diese Anzeige erhält man nur bei geschlossenem Tor.

1 - DIP 1 auf ON und anschließend DIP 3 auf ON stellen.

2 - Die grüne LED-Anzeige DL10 blinkt 6mal und zeigt den vollen Speicher an (62 vorhandene Codes).

3 - Anschließend bleibt die LED-Anzeige DL1 10 Sekunden für die Programmierung aktiv und erlaubt somit die vollständige Löschung aller Codes.

4 - Erneut DIP 1 und DIP 3 auf OFF stellen.

5 - Ende des Vorgangs.

FUNKTIONSWEISE DER STEUERZUSATZEINRICHTUNGEN

WARNUNG: VERBINDEN SIE STEUERUNG-ZUBEHÖR, NUR WENN ES AUF IMPULS-

MODUS. Stellen Sie sicher, dass alle anderen Arten von Steuerung-Zubehör (z.B.

Magnetsensoren) auf IMPULS-Modus programmiert ist, da es die Bewegung des

Tores ohne aktive Sicherheiten aktiviert.

STEUERTASTE FÜR SCHRITTWEISEN BETRIEB (COM-K BUTTON)

Steht DIP 6 auf OFF => führt einen Befehl der Steuerreihe Öffnen-Stopp-Schließen-Stopp-

Öffnen usw. aus.

Steht DIP 6 auf ON => sorgt die für die Öffnung des geschlossenen Tors. Reagiert nicht, wird die Taste während der Öffnungsbewegung gedrückt. Wird die Taste bei offenem Tor gedrückt so wird das Tor geschlossen, drückt man sie bei geschlossenem Tor, führt das zur Öffnung.

ÖFFNUNGS-TASTE (COM-OPEN)

Bei stillstehendem Tor steuert diese Taste die Öffnungsfunktion an, wird sie während des

Schließvorganges gedrückt, so wird das Tor wieder geöffnet.

DIE UHR-FUNKTON DER SCHALTTASTE ÖFFNUNG

Wenn Sie eine Uhr (oder einfach einen Schalter) gelten zu öffnen und offen zu halten, das Tor wollen, müssen Sie auf T2 24V mit fw 03 NOUP zu nehmen.

Wenn fw 03 oder höher ACHTUNG: BEI AUSFALL VON EINEM SAFETY, EINE

MINUTE NACH DIESER UHR ODER HABEN SWITCH AKTIVIERT WURDE, WIRD TÜR

OHNE SICHERHEITEN AKTIV AUF!

Diese Funktion ist besonders zur Stoßzeit nützlich, wenn der Verkehrsfluss langsam ist (zum

Beispiel bei Schichtwechsel, Notfälle im Wohn- oder Parkplatzbereich und vorrübergehend bei Umzügen).

FUNKTION UHR ANBRINGUNGSART

Anfragen Sie T2 24V mit Firmware 02.

Durch Anschluss eines Schalter und /oder einer Uhr mit Tages/Wocheneinstellung (anstatt der oder parallel zur Öffnungstaste “COM-OPEN”), kann das Tor in der Automatikeinstellung offen gehalten werden, bis der Schalter gedrückt wird oder die eingestellte Uhrzeit erreicht wurde.

Bei geöffneter Automatikeinstellung werden alle Steuerfunktionen unterdrückt.

In dem Loslassen des Schalters, oder wenn die eingestellte Zeit abgelaufen, haben Sie die sofortige Schließung der Automation.

SCHLIESSUNGS-TASTE (COM-CLOSE)

Führt bei stillstehendem offenem Tor zur Schließung.

FERNSTEUERUNG

Steht DIP 6 auf OFF => führt einen Befehl der Steuerreihe Öffnen-Stopp-Schließen-Stopp-

Öffnen usw. aus.

Steht DIP 6 auf ON => sorgt die für die Öffnung des geschlossenen Tors. Reagiert nicht, wird die Taste während der Öffnungsbewegung gedrückt. Wird die Taste bei offenem Tor gedrückt so wird das Tor geschlossen, drückt man sie bei geschlossenem Tor, führt das zur Öffnung.

TASTE ZUR FUSSGÄNGER-ÖFFNUNG (COM-PED.BUTT.)

Befehl für eine teilweise Öffnung mit nachfolgender Schließung.

Während der Öffnung der Pause oder der Schließung der Fußgänger-Öffnung, kann die

Öffnung mit jedem mit dem Steckverbinder T2 24V verbundenem Befehl geöffnet werden.

Über DIP 6 kann man die Funktionsweise der Taste zur Fußgänger-Öffnung wählen.

Steht DIP 6 auf OFF => führt einen Befehl der Steuerreihe Öffnen-Stopp-Schließen-Stopp-

Öffnen usw. aus.

Steht DIP 6 auf ON => sorgt die für die Öffnung des geschlossenen Tors. Reagiert nicht, wird die Taste während der Öffnungsbewegung gedrückt. Wird die Taste bei offenem Tor gedrückt so wird das Tor geschlossen, drückt man sie bei geschlossenem Tor, führt das zur Öffnung.

ELEKTRISCHE VERRIEGELUNG (LOCK)

DIP 8 auf ON stellen, um den Befehl für die elektrische Verriegelung während der Öffnung zu aktivieren.

FREIGABE ELEKTRISCHE VERRIEGELUNG WÄHREND DER ÖFFNUNG

DIP 9 auf ON stellen, um die Freigabe der elektrischen Verriegelung während der Öffnung zu aktivieren (dabei muss DIP 8 auf ON stehen). Wird bei geschlossenem Tor ein Öffnungsbefehl gegeben, so führt das Tor für 0,5s eine Schließbewegung aus und gleichzeitig wird die elektrische Verriegelung aktiviert (gefolgt von einer Pause von 0,5s und der Öffnung des

Tors).

FREIGABE ELEKTRISCHE VERRIEGELUNG

DIP 10 auf ON stellen, um die Freigabe der elektrischen Verriegelung während der Schließung zu aktivieren. Nach vollständiger Schließung laufen die Motoren bei voller Spannung für 0,5s um die elektrische Verriegelung zu garantieren.

ERLEICHTERTE ENTBLOCKUNG MOTOREN

DIP 11 auf ON stellen, um die manuelle erleichterte Entblockung (DIP 10 muss dabei auf ON stehen) auszuführen, nach der Schließung wird ein Umkehrvorgang für 0,2s durchgeführt, um die Entblockung zu erleichtern.

FUNKTIONSWEISE SICHERHEITSEINRICHTUNGEN

FOTOZELLE (COM-PHOT)

Steht DIP 4 auf OFF => Kommt bei geschlossenem Tor ein Hindernis in den Wirkkreis der Fotozelle, so öffnet sich das Tor nicht. Während der Funktion des Tors wirken die Fotozellen sowohl bei der Öffnung (mit

Wiederherstellung der Öffnungsbewegung nach einer halben

Sekunde) als auch bei der Schließung (mit Wiederherstellung der

Öffnungsbewegung nach einer Sekunde).

Steht DIP 4 auf ON => Kommt bei geschlossenem Tor ein Hindernis in den Wirkkreis der

44

Fotozelle und erfolgt der Öffnungsbefehl, so öffnet sich das Tor

(während der Öffnungsphase erfolgt keine Ansteuerung durch die

Fotozellen). Die Fotozellen wirken nur in der Schließungsphase (mit

Wiederherstellung der Torumsteuerung nach einer Sekunde, auch wenn die Fotozellen in Funktion bleiben).

ÜBERWACHUNG DER SOFORTIGEN SCHLIESSUNG NACH PASSIEREN DER FOTOZELLEN

Steht DIP 16 auf ON und DIP 4 auf OFF => aktivieren sich die Fotozellen während der

Öffnung, hält das Tor an und schließt sich nach nur 1 Sekunde nach Freigabe der

Fotozellen

Steht DIP 16 auf ON und DIP 4 auf ON => aktivieren sich die Fotozellen während der

Öffnung, so öffnet sich das Tor weiter. nach

Freigabe der Fotozellen hält das Tor für 1

Sekunde an und schließt sich dann.

Wird die vollständige Öffnung erreicht (nach Ende der Öffnungszeit), wird die sofortige Schließung ausgeschaltet und die automatische Schließzeit aktiviert (wenn der Trimmer TCA aktiviert ist und die LED-Anzeige DL6 leuchtet).

Kommt es während der Schließung zu einem raschen Passieren (zum Beispiel durch einen Fußgänger) öffnet sich das Tor für 2 Sekunden, um sich anschließend erneut zu schließen.

Steht DIP 12 auf OFF => sofortige Schließung nach Passierten der Fotozellen deaktiviert.

ZU BEACHTEN: Es wird empfohlen, die Funktionsweise der Fotozellen mindestens alle 6

Monate zu überprüfen.

EDGE (KONTAKTLEISTE) (COM-EDGE)

Wenn eingeschaltet, kehrt diese Funktion die Bewegung während einer Öffnung in eine

Schließbewegung um.

Wenn eingeschaltet, kehrt diese Funktion die Bewegung während einer Schließung in eine

Öffnungsbewegung um.

Bleibt die Kontaktleiste eingeschaltet, führt sie nach 2 Sekunden eine erneute Umkehr durch, um dann eine erneute kleine Umkehr auszuführen und gibt dann den Alarm einer defekten oder eingeschalteten Kontaktleiste (Kontakt NO).

Bleibt die Kontaktleiste eingeschaltet (Kontakt NO) wird keine Bewegung ermöglicht.

Wenn diese Funktion nicht benötigt wird, sind die COM-EDGE-Klemmen zu überbrücken.

ÜBERWACHUNG DER SICHERHEITSKONTAKTLEISTEN (A+TEST A-)

Durch den Eingang A+TEST und DIP 12 auf ON können die Kontaktleiste/n überwacht werden.

Die Überwachung besteht aus einem Funktionstest der Kontaktleiste, welcher bei jeder vollständigen Öffnungsbewegung des Tors durchgeführt wird. Nach jeder Öffnungsbewegung wird daher eine Schließbewegung nur dann zugelassen, wenn die Kontaktleiste/n den

Funktionstest bestanden hat/haben.

ACHTUNG: DIE ÜBERWACHUNG DES KONTAKTLEISTE-EINGANGS KANN MIT DIP 12 AUF

ON AKTIVIERT ODER MIT DIP 12 AUF OFF DESAKTIVIERT WERDEN: DER FUNKTIONSTEST

DER KONTAKTLEISTEN IST NUR DANN MÖGLICH, WENN ES SICH UM EINE VORRICHTUNG

HANDELT, DIE MIT EINER EIGENEN STEUERLEITUNG AUSGESTATTET IST.

EINE MECHANISCHE KONTAKTLEISTE KANN NICHT ÜBERWACHT WERDEN, DAHER MUSS

DIP 12 AUF OFF GESTELLT WERDEN.

SELBSTTEST-ALARM KONTAKTLEISTE (DIP 12 ON)

Wenn die Überwachung nach vollständiger Öffnung negativ ausfällt, wird ein Blinkleuchten-

Alarm ausgelöst, der aktiviert bleibt, unter dieser Bedingung wird die Schließung des Tors nicht zugelassen. Der Normalbetrieb kann nur durch Reparatur der Kontaktleiste und durch

Drücken einer des aktivierenden Befehls wieder aufgenommen werden.

STOPP-TASTE (COM-STOP)

Das Drücken der Stopp-Taste führt bei jedem Zustand des Tors zu dessen Stillstand.

Wird sie bei vollständig geöffneten Tor gedrückt (oder bei Fußgänger-Öffnung), wird vorrübergehend die automatische Schließfunktion unterbrochen (wenn diese über den

Trimmer TCA aktiviert wurde und die LED-Anzeige DL6 leuchtet). Es muss daher ein erneuter

Schließbefehl gegeben werden.

Beim anschließenden Bewegungszyklus wird die automatische Schließfunktion wieder aktiviert (wenn diese über den Trimmer TCA aktiviert wurde und die LED-Anzeige DL6 leuchtet).

ALARM STROMSENSOR

Die Steuerung T2 24V verfügt über automatische Sensoren, welche zur Bewegungsumkehr des Tors im Falle eines Zusammenstoßes mit Personen oder Gegenständen in Konformität mit den geltenden Normen EN führen (immer mit Prüfgerät die den Normen entsprechenden

Werte prüfen), ohne dabei besondere Einstelllungen an der Steuereinheit ausführen zu müssen, da diese durch eine spezielle interne Software gesteuert wird.

Falls nach einem ersten Eingreifen der Stromsensoren bei Öffnung oder Schließung (nur bei hoher Geschwindigkeit) ein zweites Eingreifen erfolgt, natürlich im umgekehrten Sinn, schließt sich das Tor und kehrt dann für eine Sekunde seine Bewegung um.

Der Alarmzustand wird durch den Blinker angezeigt, der für eine Minute aktiv bleibt, während dieser Zeitspanne ist eine Stabilisierung der Funktionsweise des Tores durch Drücken einer beliebigen Befehlstaste möglich.

ARBEIT IM MANNSBEISEIN IM FALL EINES AUSFALLS DER SICHERHEITEN

Wenn die Kontaktleiste ist defekt oder diese arbeit länger als 5 Sekunden, oder wenn die Fotozelle defekt ist oder für mehr als 60 Sekunden arbeit, die Befehle ÖFFNEN,

SCHLIESSEN, K und FUßGÄNGERZONE- TASTE im Mannsbeisein arbeiten.

Die Aktivierung dieser Meldefunktion wird durch die Programmier-LED blinkt gegeben.

Dieser Vorgang darf geöffnet oder geschlossen werden nur durch Halten der Tasten steuern.

Die Funksteuerung und automatische Schließung sind ausgeschlossen, weil ihr Betrieb nicht an die Regeln erlaubt.

Nach der Wiederherstellung der Sicherheit , ist nach einer Sekunde automatisch in automatischen Funktion oder Schritt für Schritt restauriert, und damit auch die Fernbedienung und das automatische Schließen wieder möglich.

Anmerkung 1:

(oder Fotozellen) der Fotozellen (oder Kontaktleisten) funktionieren noch,

Unterbrechung des Betriebs im Gange.

Anmerkung 2: Die Stoppen-Taste ist nicht als Sicherheitseinrichtung in diesem Modus anzusehen; so wenn gedrückt oder kaputt, erlauben Sie keines Manöver.

Die “Totmannschaltung” Bedienung ist nür eine Not-Bedienung und die, für kurze

Zeit und mit der Visuell-Sicherheit der Autmatismum-Bewegung gemacht wird sein.

So bald wie möglich, muss der Fehler Schutz, für den ordnungsgemäßen Betrieb, wiederhergestellt werden sein.

BLINKLICHT

ZU BEACHTEN: Diese Steuereinheit kann NUR BLINKER MIT BLINKKREISLAUF (ACG7061) mit Glühbirnen zu 24V und maximal 20W speisen.

FUNKTION VORBLINKEN

DIP 5 - OFF => der Motor und der Blinker aktivieren sich gleichzeitig.

DIP 5 - ON => der Blinker aktiviert sich 3 Sekunden vor dem Motor.

ANZEIGELEUCHTE TOR GEÖFFNET (COM-SIGNAL)

Diese Anzeige hat die Aufgabe, die jeweiligen Bewegungszustände (offen, teilweise offen, noch nicht vollständig geschlossen) des Tors anzuzeigen. Nur bei vollständig geschlossenem

Tor erlischt sie.

Während der Programmierung ist diese Anzeige aktiv.

ZU BEACHTEN: Max 3 W. Bei übermäßigen Einsatz der Tasten oder der Lampen kann die

Logistik der Steuereinheit in ihrer Funktionsweise beeinträchtigt werden, was zum Stoppen von Bewegungsabläufen führen kann.

FUNKTIONSWEISE NACH STROMAUSFALL (OHNE BATTERIE)

Nach der Rückkehr der Netzspannung LED DL1 sich einschaltet und bleibt die ganze Zeit.

LED DL1 sich abschaltet zum Erreichen der kompletten Schließung des Tores.

Sobald die Stromversorgung wiederhergestellt ist, wird empfohlen, das Tor vollständig zu

öffnen. Das Tor sollte sich dann selbständig schließen bei automatischer Schließung oder warten, bis der Blinker nicht mehr blinkt, um dann den Schließbefehl zu erteilen.

Dieser Vorgang dient zur Ausrichtung des Tores. Bleiben während des Stromausfalles die

Motoren blockiert und werden von ihrer normalen Schließposition entfernt, muss nach

Wiederherstellung der Stromversorgung ein kompletter Bewegungszyklus ausgeführt werden.

Wenn der Stromausfall tritt während der Bewegung, oder mit geöffnet Tor, und der erste

Befehl die Schließungsbefehl ist, wird die Schließung mit der gesamten Phasenverschiebung den Türen so, zuerst M2 schließt und nach Ausschaltung M1 schließt. Die separate

Bewegung der zwei Motoren verhindert die Überlappung der Türen.

TECHNISCHE EIGENSCHAFTEN

- Temperaturbereich

- Feuchtigkeit

- Versorgungsspannung

- Frequenz

- Batterieversorgung

- Transformatorleistung

18Vac

- Maximale Stromaufnahme

- kurze Stromunterbrechungen

- Höchstleistung Kontrollleuchte Tor geöffnet

0 ÷ 55°C

< 95% ohne Kondensierung

230V~ ±10% (120V/60Hz auf Anfrage)

50/60 Hz

20-24Vdc

130VA - primär 230Vac - sekundär

50 mA

100ms

24Vdc 3W (entspricht 1 Glühbirne mit

3W oder 5 LED mit Serienwiderstand

- Höchstbelastung am Blinker-Ausgang von 2,2 k Ohm)

24Vdc 20W

- Verfügbarere Strom für Fotozellen und Zubehör 1A ±15%

- Verfügbarere Strom auf der Funkgerätsteckverbindung 200mA

TECHNISCHE EIGENSCHAFTEN FUNKGERÄT (Modell T2 24V crx)

- Empfangsfrequenz

- Widerstand

- Empfindlichkeit

- Erregungszeit

433,92MHz

52 OHM

>2,24µV

300ms

- Entregungszeit 300ms

- Alle Eingänge müssen frei von Verunreinigungen sein, da die Speisung im Inneren der

Steckverbinder erzeugt wird, damit so die doppelte oder verstärkte Isolierung gegenüber

Teilen mit gefährlicher Spannung garantiert bleibt.

Eventuelle an den Ausgängen der Steuereinheit angeschlossene Außenschaltkreise müssen ausgeführt werden, damit doppelte oder verstärkte Isolierung gegenüber Teilen mit gefährlicher Spannung garantiert bleibt.

- Alle Eingänge werden von einem programmierten integrierten Schaltkreis gesteuert, der bei jeder Inbetriebnahme eine Selbstkontrolle einleitet.

45

D

D

LÖSUNG VON PROBLEMEN

Nachdem alle Verbindungen sorgfältig dem Schema folgend ausgeführt wurden und das Tor auf die mittlere Position gestellt wurde, das korrekte Einschalten der rot LEDs DL7 und DL8 und

DL9 kontrollieren.

Im Fall, dass sich ein LED, mit dem Tor immer noch in mittlerer Position, nicht einschaltet, wie folgt überprüfen und eventuelle, beschädigte Komponenten ersetzen.

DL7 ausgeschaltet Fotozellen beschädigt

DL8 ausgeschaltet Sicherheitsrippe Schaden (Falls die Rippe nicht angeschlossen ist einen Überbrückungsdraht zwischen COM und EDGE legen)

DL9 ausgeschaltet Stopp-Taste defekt (falls die Stopp-Taste nicht verbunden ist, eine Überbrückung zwischen COM und STOP anlegen).

Während der Totmannfunktion mit DIP 1 auf ON gestellt überprüfen, dass sich während der Öffnung von M1 und M2 die grünen LEDs DL2 und DL4 einschalten und dass bei der Schließung von M1 und M2 die roten LEDs DL3 und DL5 aufleuchten.

Im gegenteiligen fall die Anschlüsse des betreffenden Motors invertieren.

FEHLER LÖSUNG

Nachdem die verschiedenen Verbindungen gelegt sind und Strom angelegt wurde, sind alle LEDs ausgeschaltet.

Die Unversehrtheit der Sicherungen F1, FUSE 1 überprüfen.

Die Sicherungen mit geleichwerteigen ersetzen.

F1 T 2A SICHERUNG ZUM TRANSFORMATORSCHUTZ (außerhalb des Steckverbinders T2 24V)

FUSE 1 8A SICHERUNG ZUM MOTORSCHUTZ

Der Motor öffnet und schließt, aber hat keine Antriebskraft und bewegt sich langsam. Regulierung der Trimmer RUN und LOW-SPEED überprüfen.

Das Tor führt die Öffnung aus, schließt aber nicht nach der Zeit, die eingestellt ist.

Das Tor öffnet und schließt beim Betätigen der verschiedenen K, Radio, Open und

Close Tasten nicht.

Das elektrische Schloss funktioniert nicht.

Die LED-AnzeigeDL1 blinkt rasch und keine Bewegung wird zugelassen.

Kontrollieren, dass der Trimmer TCA aktiviert ist und die LED-Anzeige DL6 leuchtet.

Taste OPEN immer eingeschaltet, die Taste des OPEN-Befehls ersetzen.

Bei nichtbestandenem Autotest der Kontaktleiste, die Verbindungen zwischen Steuereinheit und

Speisegerät für die Kontaktleisten überprüfen. Achtung: verwendet man kein Speisegerät für

Kontaktleisten, Dip 12 auf OFF stellen.

Kontakt Sicherheitsrippe Schaden. Kontakt Fotozellen Schaden mit DIP 4 OFF.

Den entsprechenden Kontakt in Ordnung bringen oder ersetzen.

Vergewissern, dass DIP 8 auf ON gestellt ist.

Die Dip Switch 1, 2 oder 3 auf OFF stellen.

OPTIONEN -

Für die Anschlüsse und die technischen Daten der Zubehöre verweisen wir auf die entsprechenden Betriebsanleitungen.

BATTERIE LADEKARTE MECHANISCHER RIEGEL

BATTERIE

Kode ACG4648

Fuer zwei Fluegel, zur Verrieglung am Boden.

ELEKTRO-SCHLOSS

Kode ACG5000

Batterie 2,2Ah 12V Kode ACG9515

46

Horizontal-Schloss - rechts extern12Vac

Horizontal-Schloss - links extern12Vac

Vertikal-Schloss - 12Vac

Kode ACG8660

Kode ACG8670

Kode ACG8650

T2 24V Wi-Fi

Steuereinheit mit Anschlagsensoren und Steckverbinder MASTER Wi-Fi. Mit Gehäuse.

Kode ABT2025W

Wi-Fi VORRICHTUNGEN

MASTER Wi-Fi

KARTE FÜR DEN BETRIEB DES SYSTEMS OHNE KABEL mit Verbinder - 12÷30V ac/dc mit Endblockierung - 12÷30V ac/dc

NOVA Wi-Fi

Kode ACG6094

Kode ACG6099

VERTIGO Wi-Fi

FOTOZELLEN OHNE KABEL

EIN PAAR FOTOZELLEN - STÄNDER NOVA

BLOCK Wi-Fi

Kode ACG8037

Kode ACG8039

KABELLOSE FOTOZELLE ERSETZT DIE SCHALTLEISTEN

VERTIGO Wi-Fi 8 Kode ACG8042 - VERTIGO Wi-Fi 10 Kode ACG8043

SPARK Wi-Fi

SCHLÜSSELSCHALTER OHNE KABEL Kode ACG7064

Kode ACG7042 Kode ACG6098

47

BLINKER OHNE KABEL

SEITENLAGER

D

E

S

DISPOSICIÒN DE LA INSTALACIÒN

2

5 1

1 - Operador PRINCE

2 - Antena de radio

3 - Intermitente

4 - Interruptor de llave

5 - Fotocélulas esternas

3

CARACTERÍSTICAS TÉCNICAS

PRINCE es un operador capaz de desplazar cancelas con batientes de hojas largas hasta 3 m y pesadas hasta 250 kg (Fig. 1).

PRINCE ha sido concebido para trabajar sin finales de carrera eléctricos, sino sólo mecánicos.

N. B.: Para asegurar un cierre eficaz, es necesario utilizar un electrocierre.

1 5 4

4

1

CARACTERÍSTICAS TÉCNICAS

Longitud máxima de la anta

Peso máx cancela

Corrido max de arrastre

Tiempo de abertura

Velocidad de arrastre

Alimentación e frequenza

Potencia nominale (a 71 rpm vite)

Potencia a blocco

Absorcion nominale

Absorcion a blocco

Fuerza nominale

Fuerza a blocco

Ciclos normativos

Ciclos diarios sugeridos

Servicio

Ciclos garantizados

Peso motor

Nivel de ruido

Temperatura de trabajo

Nivel de protección m kg mm s.

m/s n° n°

N

N

%

W

W

A

A n° kg db

°C

IP

** Con el seguro mecánico incorporado que interviene durante la abertura. Si se utiliza también el seguro mecánico que interviene durante el cierre, opcional, la carrera máxima de remolque se reduce de 30 mm.

PRINCE 24V

89

0,88

3,72

1000

1500

∞ - 14s/2s

60

3

250

343**

14

0,0134

24Vdc

12

80

60/14s

5

<70

-30 ÷ +55°C

44

Medidas en mm

2

48

INSTALACIÓN PRINCE

CONTROLES DE LA PRE-INSTALACIÓN

La puerta de batiente debe fijarse sólidamente a las bisagras de las columnas y no debe balancearse durante el movimiento.

Antes de proceder a la instalación de PRINCE, es prudente verificar todos los espacios necesarios para emplazarlo. Si la cancela se presenta como en la Fig. 1, no hace falta efectuar ninguna modificación.

N.B. Es obligatorio adecuar las características de la cancela a las normas y leyes vigentes.

La puerta puede ser automatizada sólo si se encuentra en buen estado y responde a la norma

EN 12604.

- La puerta no tiene que tener puertas peatonales. De lo contrario se tendrán que tomar las oportunas precauciones de acuerdo con el punto 5.4.1 de la EN12453 (por ejemplo impedir el movimiento del motor cuando la puertecilla está abierta, gracias a un microinterruptor debidamente conectado a la central).

- No hay que generar puntos donde se pueda quedar atrapado (por ejemplo entre la puerta de la cancela y la verja).

Componentes a instalar según la norma EN12453

TYPO DE MANDO

Personas expertas

(fuera de un área pública*)

USO DEL CIERRE

Personas expertas

(área pública) en presencia de alguien con impulsos a la vista

(ej. sensor) con impulso no a la vista

(ej. telemando) automatico

A

C o E

C o E

C e D, o E

B

C o E

C e D, o E

C e D, o E

Uso ilimitado non posivel

C e D, o E

C e D, o E

C e D, o E

*un ejemplo típico son los cierres que no dan a la calle.

A: Pulsador de mando en presencia de alguien, (es decir con acción mantenida), como cód. ACG2013.

B: Interruptor de llave en presencia de alguien, como cód. ACG1010.

C: Regulacion de la fuerza del motor.

D: Nervaduras como cód. ACG3010 y / o otros dispositivos que limitan las fuerzas entre limites de las normas EN 12453 - Appendix A.

E: Fotocélulas, como cód. ACG8026 (Da applicare cada 60÷70 cm por toda la altura de la puerta hasta un máximo de 2,5 m (EN 12445 punto 7.3.2.1).

DESBLOQUEO DE URGENCIA

En el caso de falta de corriente para poder accionar la cancela es suficiente introducir la respectiva llave y girarla de 90° en sentido antihorario (Fig. 3).

Para poder realizar en modo seguro el desplazamiento manual de la puerta hay que controlar que:

- Las manillas de la puerta que se han proporcionado sean idóneas;

- Estas manillas no estén posicionadas en modo de crear puntos de peligro durante su utilizo;

- El esfuerzo manual para mover la puerta no debe superar los 225N para las cancelas colocadas en lugares privados y los 390N para las cancelas colocadas en sitios comerciales e industriales (valores indiacados en el punto 5.3.5 de la norma EN 12453).

FIJACIÓN DEL ENGANCHE DEL MOTOR A LA COLUMNA

Instalando el PRINCE es necesario respetar algunas medidas para obtener un correcto desplazamiento de la puerta (Fig. 4, 5, 7, 8, 9)

Si la columna está hecha de hierro, se puede tornillo con 4 tornillos de Fischer de Ø 8 milímetros.

Si la columna es de cemento se la fija con cuatro tornillos de expansión de Ø 8 mm.

En el caso de que se tenga la pared paralela a la cancela cuando ésta se encuentra abierta, puede ser necesario hacer una encajadura para el operador.

FIJACIÓN DEL ENGANCHE DEL MOTOR A LA CANCELA

Soldar el enganche a la altura correcta (Fig. 6, 9).

Instalar el PRINCE probando a abrir y cerrar repetidas veces, verificando que el perfil cubretornillos no roce con la cancela en movimiento.

49

3

4

5

engrasar cuidadosamente

6

SÍ !

Asegúrese de apretar el tornillo que sujeta el soporte al operador, de modo que puede girar libremente.

7

NO !

El operador no debe variar su altura durante el movimiento.

8

E

S

E

S

S1

Z

Y

X

Cumplir con la medida y asegurarse de que el operador esté en posición horizontal

S2

Z

Y

X

COL

Enganche columna

Z

Y

X

S3

Medidas a respetar para una instalación correcta

L

Min.÷Max

1÷3 a

A max

B C D E

T sec

COL ANT

90°

0 100 100 765 90 13,5 S2-X A

20 100 100 765 90 13,5

S2-Y A

40 100 100 765 90 13,5 S3-X A

60 110 100 765 90 14 S3-Y A

80 140 110 765 115 17 S3-X B

100 160 110 765 115 18

S3-X B

120 180 110 765 115 19,5 S3-X B

140 210 110 765 115 21,5 S1-Z B

150 220 120 765 115 23 S1-Z B

110°

20 110 140 765 90 17

S1-Y A

ANT

Enganche cancela

A

B

Medidas a respetar CON 2 SEGUROS MECÁNICOS

L

Min.÷Max

1÷3 a

A max

B C D E

T sec

COL ANT

0 100 100 730 90 13,5 S2-X A

20 100 100 730 90 13,5

S2-X A

40 100 100 730 90 13,5 S3-X A

60 110 100 730 90 14 S3-X A

90°

80 140 110 730 115 17 S3-X B

100 160 110 730 115 18

S3-X B

110 180 120 730 115 20 S1-Z B

110°

20 100 140 730 90 16 S2-Y A

En el caso de que el pilar fuera demasiado ancho y no fuese posible instalar el electroreductor respetando la medida (B), es indispensable crear una encajadura en el pilar o desplazar la cancela hacia la esquina.

9

50

SEGURO MECÁNICO - OPTIONAL

Seguro mecánico opcional para detener el cierre en el caso de que la cancela no esté provisto de una seguro de tierra.

AJUSTE DE LOS FINALES DE CORRIDA MECÁNICOS

Para posicionar los seguros se debe actuar según el esquema (Fig. 11).

Para obtener la abertura deseada es suficiente mover el seguro (A) y boquearlo serrando la vite da 8mA con la llave fija n° 13.

Para obtener el cierre deseado se tendrá que mover el seguro (B) (OPCIONAL) bloccandolo come descritto per il fermo (A).

MANTENIMIENTO

Estas operaciones deben ser efectuadas exclusivamente por personal especializado y con el motor desconectado de la alimentación eléctrica.

Todos los años, engrasar las bisagras y controlar la fuerza de empuje ejercida por el motorreductor sobre la puerta.

Cada dos años, se aconseja sustituir el aceite y lubricar la tuerca de husillo con grasa de silicona.

CONEXIONES ELÉCTRICAS

A B

C

51

D

10

11

E

S

E

S

T2 24V cód. AC07088

T2 24V CRX cód. AC07089

ANTENA

COMÚN

CIERRE

APERTURA

STOP

MASA

ANTENA

LED

24Vdc 0,8A ± 15% para ACCESSORIOS

24Vdc 0,8A ± 15% para AUTOTEST COSTAS

INTERMITENTE

24Vdc 20W

PEATONAL

PASSO PASSO

FOTOCÉLULAS

COMÚN

COSTAS

R=2,2K 1/4W

CERRADURA

ELÉCTRICA

ALIMENTACION

230Vac 50Hz

FUSIBLE

T 2 A

TRANSFORMADOR

M1

M2

52

J1

J2

J3

J4

J5

J6

J7

J8

J9

J10

TR1

TR2

TR3

N F

COM.

CLOSE

OPEN

STOP

AERIAL

SIGNAL

A+TEST

EDGE N.C.

COM.

PHOTO N.C.

K BUTT.

PED. BUTT.

A+

A -

LOCK

SECONDARY

TRANSFORMER

MOTOR 1

MOTOR 2

SW T2 24V

SW RADIO

RADIO

BATTERY

CHARGER

TRIMMER RUN

TRIMMER LOW

SPEED

TRIMMER TCA

Alimentación 230 Vac 50/60 Hz - externa a la tarjeta -

(120V/60Hz bajo pedido)

Común de los contactos

Contacto para impulsos de cierre (NA)

Contacto para impulsos de apertura (NA)

Contacto para impulsos de stop (NC)

Antena radio

Indicador luminoso de cancela abierta y señal del estado de funcionamiento con batería y baterías descargadas (24Vdc

3W máx)

Positivo para alimentación autotest costa

Contacto costa (NC)

Común de los contactos

Contacto de las fotocélulas (NC)

Contacto para impulsos individuales (NA)

Contacto del mando abertura peatonal (NA)

Positivo para alimentación accesorios 24Vdc

Negativo para alimentación accesorios 24Vdc

Conexión cerradura eléctrica (MAX 15W 12V)

Conexión fase negativa del intermitente de 24Vdc (cód.

ACG7061) Cuidado con la polaridad

Conector para transformador secundario 18 Vac

A - CONEXIÓN

J9

J10

J8

Conexión MOTOR 1 (sin polaridad)

Conexión MOTOR 2 (sin polaridad)

Conector dedicado para la programación en fábrica. ¡NO

TOCAR EL PUENTE! ¡SI ES REMOVIDO EL OPERADOR NO

FUNCIONA!

Conector dedicado para la programación en fábrica (sólo para los modelos CRX) ¡NO TOCAR EL PUENTE! ¡SI ES

REMOVIDO EL SISTEMA DE RADIO NO FUNCIONA!

Módulo radio incorporado (modelo CRX), o conector para radio receptor RIB con engranaje con alimentación de 24Vdc

Conector para tarjeta para la recarga de batería de 24Vdc

(cód. ACG4648)

Trimmer de reglamento de la alta velocidad

Trimmer de reglamento de la velocidad lenta

J7

S3

Trimmer de reglamento del tiempo de esperada antes de tener del cierre automático (por defecto NO HABILITADO y

LED DL6 APAGADO)

S3 PROG

FUSE 1 T 8 A

F1 T 2 A

J2 J3

J1

TR1 TR2

Pulsador para la programación

Fusible para la protección de los motores

Fusible para la protección del transformador

F1

TRANSFORMER

J4

FUSE 1

J5

J6

TR3

B - CONFIGURACIÓN

DIP 1 (ON) - CONTROL DEL SENTIDO DE ROTACIÓN DEL MOTOR (PUNTO C)

DIP 2 (ON) - PROGRAMACIÓN TIEMPOS (PUNTO D)

DIP 3 (ON) - HABILITACIÓN PARA LA LIBERACIÓN DE LAS PUERTAS DURANTE LAS

FASES DE DESACELERACIÓN, APERTURA Y CIERRE TOTAL (EN RESPETO DE

LAS PRUEBAS DE IMPACTO SEGÚN LA NORMA EN12453)

DIP 1-2 MEMORIZACIÓN/CANCELACIÓN DE LOS CÓDIGOS DE RADIO PARA MANDO DE

APERTURA TOTAL (SOLO MODELOS CRX) (PUNTO E)

DIP 1-3 MEMORIZACIÓN/CANCELACIÓN DE LOS CÓDIGOS DE RADIO PARA MANDO DE

APERTURA PEATONAL (SOLO MODELO CRX) (PUNTO F)

DIP 2-1 PROGRAMACIÓN DE LOS TIEMPOS DE APERTURA PEATONAL

MICROINTERRUPTORES DE GESTIÓN

DIP 4 Fotocélulas siempre activas (OFF) - Fotocélulas activas solo en cierre (ON)

DIP 5 Preintermitencia (ON) - Intermitencia normal (OFF)

DIP 6 Mando impulso individual (K BUTT) y Receptor radio paso paso (OFF) - automático

(ON)

DIP 7 Funcionamiento con sensor de corriente (ON-activado) Funcionamiento por tiempo

(OFF-activado).

DIP 8 Habilitación cerradura eléctrica (ON-activado)

DIP 9 Habilitación golpe de desenganche de la cerradura eléctrica (ON-activada)

DIP 10 Habilitación golpe de desenganche de la cerradura eléctrica (ON- activado)

DIP 11 Habilitación desbloqueo facilitado (ON-activada)

DIP 12 Habilitación TEST monitorización costa (ON- activado).

DIP 13 Selección funcionamiento con 1 o 2 motores (por defecto OFF 2 motores)

DIP 14 OFF

DIP 15 OFF

DIP 16 CIERRE IMMEDIATO TRAS HABER TRANSITADO DELANTE DE LAS FOTOCÉLULAS

ON HABILITADA

OFF DESHABILITADA

JP1 => Compruebe que el puente se inserta!

JP2 => Compruebe que el puente se inserta!

JP3 => Compruebe que el puente se inserta!

PROG => S3 Botón para programación

REGULACIONES

ATENCIÓN: PONER EL DIP 3 EN ON, SOLO DESPUÉS DE HABER TERMINADO TODAS

LAS PROGRAMACIÓNES.

NOTA: CON DIP 3 (ON) SE HABILITA LA FUNCIÓN DE BREVE INVERSIÓN DE LAS

PUERTAS DESPUÉS DEL IMPACTO

ESTA BREVE INVERSIÓN DE LAS PUERTAS PERMITE REDUCIR A CERO LA FUERZA

ESTÁTICA DENTRO DE LOS 5 SEGUNDOS INDICADOS POR LA NORMA EN12453 EN

EL PUNTO A.2.2 (FUERZAS ESTÁTICAS ADMISIBLES) PERMITIENDO, POR LO TANTO,

RESPETAR LAS PRUEBAS DE IMPACTO INDICADAS EN LA NORMATIVA EN12453.

EN CASO DE QUE NO SEA NECESARIO OBEDECER LA NORMA ARRIBA DESCRITA,

BASTA COLOCAR EL DIP 3 EN POSICIÓN OFF. EN ESTE CASO LAS PUERTAS SE

DETENDRÁN SIN INVERTIR EL MOVIMIENTO.

TRIMMER RUN (TR1) Regulador electrónico de la alta velocidad

Con este trimmer es posible regular la velocidad del motor (por defecto se configura al máximo de la velocidad). La regulación resulta de gran utilidad, pues permite que la automatización sea conforme a las normas europeas en materia de impactos.

53

E

S

E

S

TRIMMER LOW SPEED (TR2) Regulador electrónico de la velocidad lenta en acercamiento

La regulación de la velocidad lenta se realiza actuando sobre el Trimmer LOW SPEED mediante el cual se modifica la tensión de salida a los extremos del/ de los motor/es

(girándolo en sentido horario se aumenta la velocidad). La regulación se realiza para determinar la correcta velocidad de final de apertura y final de cierre, en base a la estructura de la cancela, o en presencia de rozamientos leves, que podrían comprometer el correcto funcionamiento del sistema.

TRIMMER DE CIERRE AUTOMATICO TCA (TR3) TOTAL O PEATONAL por defecto NO

HABILITADO y LED DL6 APAGADO (TRIMMER GIRADO COMPLETAMENTE EN SENTIDO

ANTIHORARIO)

Con este trimmer es posible realizar la regulación del tiempo, antes de que se produzca el cierre automático total o peatonal. Se obtiene solo con la puerta completamente (total) o parcialmente (peatonal) abierta y el led DL6 encendido (con trimmer girado en sentido horario).

El tiempo de pausa puede ser regulado por un mínimo de 2 segundos y un máximo de 2 minutos.

SEÑALIZACIONES LED

DL1 programación activada (rojo)

DL2 cancela en apertura M2 (verde)

DL3 cancela en cierre M2 (rojo)

DL4 cancela en apertura M1 (verde)

DL5 cancela en cierre M1 (rojo)

DL6 señalización del tiempo de cierre automático (rojo)

DL7 contacto fotocélulas (NC) (rojo)

DL8 contacto costa (NC) (rojo)

DL9 mando pulsador STOP (NC) (rojo)

DL10 programación códigos de radio (verde)

FUSIBLES

Fuse 1 T 8A FUSIBLE PARA LA PROTECCIÓN DE LOS MOTORES

F1 T 2A FUSIBLE PARA LA PROTECCIÓN DEL TRANSFORMADOR (externo a la tarjeta T2

24V)

C - CONTROL DEL SENTIDO DE ROTACIÓN DEL/DE LOS MOTOR/ES

1 - Coloque DIP 1 en posición ON => El led DL1 comienza a parpadear.

2 - Presione y mantenga presionado el pulsador PROG. (ahora el movimiento se lleva a cabo en presencia de personas, abre-stop-cierra-stop-abre-etc.) => LOS LED VERDES

DL2 y DL4 se encienden y las puertas de la cancela se abren con un desfase fijo de 2 segundos. Si se cierran en lugar de abrirse, libere el pulsador e invierta los dos cables del motor involucrado.

3 - Al final de la apertura, libere el pulsador PROG y realice el calibrado de los retenes mecánicos de apertura (presentes en el operador)

4 - Presione y mantenga presionado el pulsador PROG => LOS LED ROJOS DL3 y DL5 se encienden y las puertas de la cancela se cierran con un desfase de 2 segundos.

5 - Mantenga presionado el pulsador PROG hasta que la cancela no esté completamente cerrada.

6 - Deje las 2 puertas completamente cerradas para efectuar la programación de los tiempos.

7 - Vuelva a colocar DIP1 en posición OFF => El led DL1 se apaga indicando la salida del control.

NOTA: Durante este control el stop, las fotocélulas y las costas no están activas.

D - PROGRAMACIÓN DE LOS TIEMPOS PARA 2 MOTORES (#) CON SENSOR DE

CORRIENTE HABILITADO (DIP 7 ON)

DURANTE LA PROGRAMACIÓN EL SENSOR DE CORRIENTE ESTÁ SIEMPRE ACTIVO

1 - La cancela debe estar completamente cerrada.

2 - Coloque el DIP 2 en posición ON => El led DL1 emitirá parpadeos breves.

3 - Presione el pulsador PROG. => M1 se abre.

4 - Una vez alcanzado el seguro mecánico de apertura, el SENSOR DE CORRIENTE

AUTOMÁTICO detiene M1 (con memorización del tiempo y de la corriente)=> En el mismo momento, se activa M2 y abre.

5 - Una vez alcanzado el seguro mecánico de apertura, el SENSOR DE CORRIENTE

AUTOMÁTICO detiene M2 (con memorización del tiempo y de la corriente).

6 - Presione el pulsador PROG. => M2 se cierra.

7 - Presione el pulsador PROG. => M1 se cierra determinando el espacio de desfase entre

M2 y M1. En el mismo momento el led DL1 dejará de parpadear, indicando la salida del procedimiento de memorización.

Desde este momento, las seguridades o los otros mandos de la cancela funcionarán normalmente (inversiones, stop, alarmas, etc.).

8 - El cierre de las puertas será ejecutado en modalidad rápida (en base a lo que se ha configurado en el trimmer RUN) y en proximidad del cierre total en modalidad desacelerada (en base a lo que se ha configurado en el trimmer LOW SPEED).

9 - Al alcanzar el cierre, los sensores de corriente detienen la cancela.

10 - AL FINALIZAR LA PROGRAMACIÓN VUELVA A COLOCAR EL DIP 2 EN POSICIÓN OFF.

D - PROGRAMACIÓN DE LOS TIEMPOS PARA 1 MOTOR (M1) (#) CON SENSOR

DE CORRIENTE HABILITADO (DIP 7 ON)

ATENCIÓN: PARA GESTIONAR UN SOLO MOTOR EL DIP 13 DEBE ESTAR COLOCADO

EN POSICIÓN ON; DURANTE LA PROGRAMACIÓN EL SENSOR DE CORRIENTE ESTÁ

SIEMPRE ACTIVO.

La cancela debe estar completamente cerrada.

1 - Coloque el DIP 2 en posición ON => El led DL1 emitirá parpadeos breves.

2 - Presione el pulsador PROG. => M1 se abre.

Una vez alcanzado el seguro mecánico de apertura, el SENSOR DE CORRIENTE detiene

M1 (con memorización del tiempo y de la corriente).

3 - Presione el pulsador PROG. => M1 se cierra.

En el mismo momento el led DL1 dejará de parpadear, indicando la salida del procedimiento de memorización. Desde este momento, las seguridades o los otros mandos de la cancela funcionarán normalmente (inversiones, stop, alarmas, etc.).

Al alcanzar el cierre, mediante el sensor de corriente, la cancela se detiene.

4 - AL FINALIZAR LA PROGRAMACIÓN VUELVA A COLOCAR EL DIP 2 EN POSICIÓN OFF.

(#)

INTERVENCIÓN DETIENE LA PROGRAMACIÓN (EL LED DL1 DE INTERMITENTE

CAMBIA A ENCENDIDO FIJO). PARA REPETIR LA PROGRAMACIÓN COLOQUE EL

DIP 2 EN POSICIÓN OFF, CIERRE LA CANCELA MEDIANTE EL PROCEDIMIENTO

DE “CONTROL DEL SENTIDO DE ROTACIÓN DE LOS MOTORES” Y REPITA LA

PROGRAMACIÓN ELEGIDA.

PROGRAMACIÓN DE LOS TIEMPOS PARA 2 MOTORES (#) CON

FUNCIONAMIENTO POR TIEMPO (DIP 7 OFF)

1 - La cancela debe estar completamente cerrada.

2 - Coloque el microinterruptor DIP 2 en posición ON => El led DL1 emitirá parpadeos breves.

3 - Presione el pulsador PROG. => M1 se abre.

4 - Una vez alcanzado el seguro mecánico de apertura, después de un segundo, presione el pulsador PROG. => M1 se detiene y M2 abre.

5 - Una vez alcanzado el seguro mecánico de apertura => después de 1 segundo, presione el pulsador PROG. => M2 si detiene.

6 - Presione el pulsador PROG. => M2 se cierra.

7 - Presione el pulsador PROG. => M1 se cierra determinando el desfase entre M2 y M1.

En el mismo momento, el led DL1 dejará de parpadear, indicando la salida del procedimiento de memorización.

Desde este momento, las seguridades o los otros mandos de la cancela funcionarán normalmente (inversiones, stop, alarmas, etc.).

8 - Una vez finalizado el cómputo del tiempo, la cancela se detiene.

9 - AL FINALIZAR LA PROGRAMACIÓN, VUELVA A COLOCAR EL DIP 2 EN POSICIÓN OFF.

NOTA: La desaceleración se determina automáticamente por el cuadro electrónico en fase de programación de tiempos, y se activa a aproximadamente 50÷60 cm antes de alcanzar los finales de carrera mecánicos de apertura o cierre.

PROGRAMACIÓN DE LOS TIEMPOS PARA 1 MOTOR (#) CON

FUNCIONAMIENTO POR TIEMPO (DIP 7 OFF)

ATENCIÓN: PARA GESTIONAR UN SOLO MOTOR, EL DIP 13 DEBE ESTAR COLOCADO

EN POSICIÓN ON.

1 - La cancela debe estar completamente cerrada.

2 - Coloque el microinterruptor DIP 2 en posición ON => El led DL1 emitirá parpadeos breves.

3 - Presione el pulsador PROG. => M1 se abre.

4 - Una vez alcanzado el seguro mecánico de apertura, después de un segundo, presione el pulsador PROG. => M1 se detiene.

5 - Presione el pulsador PROG. => M1 se cierra.

En el mismo momento el led DL1 dejará de parpadear, indicando la salida del procedimiento de memorización.

Desde este momento, las seguridades o los otros mandos de la cancela funcionarán normalmente (inversiones, stop, alarmas, etc.).

6 - Una vez que el cómputo del tiempo finaliza, la cancela se detiene.

7 -

AL FINALIZAR LA PROGRAMACIÓN VUELVA A COLOCAR EL DIP 2 EN POSICIÓN OFF.

D - PROGRAMACIÓN DE LOS TIEMPOS DE APERTURA PEATONAL (#) TANTO PARA

EL FUNCIONAMIENTO POR TIEMPO COMO PARA EL FUNCIONAMIENTO CON

SENSOR DE CORRIENTE

Con la cancela cerrada:

1 - Coloque primero el DIP2 en posición ON (el led DL1 parpadea rápidamente) y después el

DIP1 en posición ON (el led DL1 parpadea lentamente).

2 - Presione el pulsador peatonal (COM-PED.BUTT) => M1 se abre.

3 - Presione el pulsador peatonal para detener la carrera (definiendo así la apertura de M1)

4 - Presione el pulsador peatonal para poner en marcha el cierre.

5 - Al alcanzar el cierre, vuelva a colocar los DIP 1 y 2 en posición OFF.

(#) DURANTE LA PROGRAMACIÓN LAS SEGURIDADES ESTÁN ACTIVAS Y SU

INTERVENCIÓN DETIENE LA PROGRAMACIÓN (EL LED DL1 DE INTERMITENTE

CAMBIA A ENCENDIDO FIJO).

PARA REPETIR LA PROGRAMACIÓN COLOQUE LOS DIP1 Y 2 EN POSICIÓN OFF,

CIERRE LA CANCELA MEDIANTE EL PROCEDIMIENTO DE “CONTROL DEL SENTIDO

DE ROTACIÓN DE LOS MOTORES” Y REPITA LA PROGRAMACIÓN ELEGIDA.

E - PROGRAMACIÓN DE LOS CÓDIGOS DE RADIO APERTURA TOTAL

(MÁX. 62 CÓDIGOS - SOLO MODELOS CRX)

La programación puede llevarse a cabo únicamente con la cancela detenida.

1 - Coloque el DIP 1 en posición ON y, sucesivamente, el DIP2 en ON

2 - El led rojo DL1 de programación parpadea con una frecuencia de 1 seg. ON y 1 seg.

54

OFF durante 10 segundos.

3 - Presione la tecla del mando a distancia (normalmente el canal A) dentro de los 10 segundos programados. Si el mando a distancia se memoriza correctamente, el led DL10

(verde) emite un parpadeo.

4 - El tiempo de programación de los códigos se renueva automáticamente para poder memorizar el mando a distancia sucesivo.

5 - Para terminar la programación deje transcurrir 10 segundos o presione por un instante el pulsador PROG. El led rojo DL1 de programación deja de parpadear

6 - Vuelva a colocar el DIP 1 en posición OFF y el DIP2 en OFF

7 - Final del procedimiento.

PROCEDIMIENTO CANCELACIÓN DE TODOS LOS CÓDIGOS DE RADIO DEDICADOS A LA

APERTURA TOTAL

La cancelación puede llevarse a cabo únicamente con la cancela detenida.

1 - Coloque el DIP 1 en posición ON y, sucesivamente, el DIP2 en ON

2 - El led rojo DL1 de programación parpadea con una frecuencia de 1 seg. ON y 1 seg.

OFF durante 10 segundos.

3 - Presione y mantenga presionado el pulsador PROG durante 5 segundos. La cancelación de la memoria se señala mediante dos intermitencias del led verde DL10

4 - El led rojo DL1 de programación permanece activo y es posible introducir nuevos códigos siguiendo los procedimientos arriba descritos.

5 - Vuelva a colocar el DIP 1 en posición OFF y el DIP2 en OFF

6 - Final del procedimiento.

SEÑALIZACIÓN DE MEMORIA SATURADA POR LOS CÓDIGOS DE RADIO DEDICADOS A

LA APERTURA TOTAL

La señalización se puede obtener únicamente con la cancela detenida.

1 - Coloque el DIP 1 en posición ON y, sucesivamente, el DIP2 en ON

2 - El led verde DL10 parpadea 6 veces indicando la condición de memoria saturada (62 códigos presentes)

3 - Sucesivamente, el led DL1 de programación permanece activo por 10 segundos, permitiendo una posible cancelación de todos los códigos.

4 - Vuelva a colocar el DIP 1 en posición OFF y el DIP2 en OFF

5 - Final del procedimiento.

F - PROGRAMACIÓN DE LOS CÓDIGOS DE RADIO DE APERTURA PEATONAL

(MÁX. 62 CÓDIGOS - SOLO MODELOS CRX)

La programación puede llevarse a cabo únicamente con la cancela detenida.

1 - Coloque el DIP1 en posición ON y, sucesivamente, el DIP3 en ON

2 - El led rojo DL1 de programación parpadea con una frecuencia de 1 seg. ON y 1 seg.

OFF durante 10 segundos.

3 - Presione la tecla del mando a distancia (normalmente el canal B) dentro de los 10 segundos programados. Si el mando a distancia se memoriza correctamente, el led DL10

(verde) emite un parpadeo.

4 - El tiempo de programación de los códigos se renueva automáticamente para poder memorizar el mando a distancia sucesivo.

5 - Para terminar la programación deje transcurrir 10 segundos o presione por un instante el pulsador PROG. El led rojo DL1 de programación deja de parpadear

6 - Vuelva a colocar el DIP 1 en posición OFF y el DIP3 en OFF

NOTA: SI EL LED DL1 CONTINÚA PARPADEANDO RÁPIDAMENTE, SIGNIFICA QUE

EL DIP1 AÚN ESTÁ COLOCADO EN POSICIÓN ON Y CUALQUIER MANIOBRA SERÁ

DENEGADA.

7 - Final del procedimiento.

PROCEDIMIENTO DE CANCELACIÓN DE TODOS LOS CÓDIGOS DE RADIO DEDICADOS A

LA APERTURA PEATONAL

La cancelación puede llevarse a cabo únicamente con la cancela detenida.

1 - Colocar el DIP 1 en posición ON y, sucesivamente, el DIP3 en ON

2 - El led rojo DL1 de programación parpadea con una frecuencia de 1 seg. ON y 1 seg.

OFF durante 10 segundos.

3 - Presione y mantenga presionado el pulsador PROG durante 5 segundos. La cancelación de la memoria se señala mediante dos intermitencias del led verde DL10

4 - El led rojo DL1 de programación permanece activo y es posible introducir nuevos códigos siguiendo los procedimientos arriba descritos.

5 - Vuelva a colocar el DIP 1 en posición OFF y el DIP3 en OFF

6 - Final del procedimiento.

SEÑALIZACIÓN DE MEMORIA SATURADA CÓDIGOS DE RADIO DEDICADOS A LA

APERTURA PEATONAL

La señalización se puede obtener únicamente con la cancela detenida.

1 - Coloque el DIP 1 en posición ON y, sucesivamente, el DIP3 en ON

2 - El led verde DL10 parpadea 6 veces indicando la condición de memoria saturada (62 códigos presentes)

3 - Sucesivamente, el led DL1 de programación permanece activo por 10 segundos, permitiendo una posible cancelación de todos los códigos.

4 - Vuelva a colocar el DIP 1 en posición OFF y el DIP3 en OFF

5 - Final del procedimiento.

FUNCIONAMIENTO ACCESORIOS DE MANDO

ADVERTENCIA: CONECTE ACCESORIOS DE COMANDO SOLO SI IMPULSIVO

Asegúrese de que cualquier otro accesorios de comando que se instalan (por ejemplo, sensores magnéticos) están programados en el modo de IMPULSO, de lo contrario pueden activar el movimiento de la puerta sin tener activos los elementos de seguridad.

PULSADOR DE MANDO PASO-PASO (COM-K BUTTON)

Si DIP 6 en OFF => Ejecute un mando cíclico de órdenes abre-stop-cierra-stop-abre etc.

Si DIP 6 en ON => Ejecute la apertura con cancela cerrada. Si se acciona durante el movimento de apertura, no tiene efecto. Si se acciona con la cancela abierta, la cierra y, si se acciona durante el cierre, la vuelve a abrir.

PULSADOR DE APERTURA (COM-OPEN)

Con la cancela detenida, el pulsador ordena el mando de apertura. Si se lo acciona durante el cierre, vuelve a abrir la cancela.

FUNCIÓN RELOJ DEL PULSADOR DE APERTURA

Si desea aplicar un reloj (o más simplemente un interruptor) para abrir y mantener abierta la puerta, usted tiene que tomar T2 24V con fw 03 NOUP.

Si fw 03 o superior ATENCION: EN CASO DE INCUMPLIMIENTO DE UNA

SEGURIDAD, UN MINUTO DESPUÉS DE QUE EL RELOJ O INTERRUPTOR HAN SIDO

ACTIVADOS, PUERTA SIN SEGUROS ACTIVO ABRIRÁ!

La Función Reloj es útil durante las horas pico, cuando el tráfico vehicular es lento (por ej. entrada/salida de trabajadores, emergencias en zonas residenciales o zonas de aparcamientos y, temporalmente, por mudanzas).

MODALIDAD DE APLICACIÓN FUNCIÓN RELOJ

Solicitar T2 24V con firmware 02.

Conectando un interruptor y/o un reloj de tipo diario/semanal (en el lugar o en paralelo al pulsador de apertura N.O. “COM-OPEN”) es posible abrir y mantener abierta la automatización hasta que el interruptor es presionado o el reloj permanece activo.

Con la automatización abierta se inhiben todas las funciones de mando.

Liberando el interruptor, o cuando expira la hora configurada, se obtendrá el cierre inmediato de la automatización.

PULSADOR DE CIERRE (COM-CLOSE)

Con la cancela detenida, ordena el movimiento de cierre.

MANDO A DISTANCIA

Si DIP 6 en OFF => Ejecute un mando cíclico de órdenes abre-stop-cierra-stop-abre etc.

Si DIP 6 en ON => Ejecute la apertura con cancela cerrada. Si se acciona durante el movimento de apertura, no tiene efecto. Si se acciona con la cancela abierta, la cierra y, si se acciona durante el cierre, la vuelve a abrir.

PULSADOR DE APERTURA PEATONAL (COM-PED BUTT.)

Mando dedicado a una apertura parcial y a su cierre.

Durante la apertura, la pausa o el cierre peatonal, es posible ordenar la apertura desde cualquier mando conectado a la tarjeta T2 24V.

Mediante el DIP6 es posible elegir la modalidad de funcionamiento del pulsador de mando peatonal.

Si DIP 6 en OFF => Ejecute un mando cíclico de órdenes abre-stop-cierra-stop-abre etc.

Si DIP 6 en ON => Ejecute la apertura con cancela cerrada. Si se acciona durante el movimento de apertura, no tiene efecto. Si se acciona con la cancela abierta, la cierra y, si se acciona durante el cierre, la vuelve a abrir.

CERRADURA ELÉCTRICA (LOCK)

Coloque el DIP8 en posición ON para habilitar el mando de la cerradura eléctrica en apertura.

GOLPE DE DESENGANCHE DE LA CERRADURA ELÉCTRICA EN APERTURA

Coloque el DIP9 en posición ON para habilitar el golpe de desenganche de la cerradura eléctrica en apertura (bajo la condición de que DIP8 esté en ON).

Con la cancela cerrada, si se presiona un mando de apertura, la cancela durante 0,5s ejecuta la maniobra de cierre y, contemporáneamente, se activa la cerradura eléctrica

(seguida por 0,5s de pausa y por la apertura de la cancela)

GOLPE DE DESENGANCHE DE LA CERRADURA ELÉCTRICA

Coloque el DIP10 en posición ON para habilitar el golpe de desenganche de la cerradura eléctrica en cierre. Una vez que se produjo el cierre, se gestionan por 0,5s los motores a plena tensión para garantizar el enganche de la cerradura.

FACILITACIÓN DESBLOQUEO MOTORES

Coloque el DIP11 en posición ON para habilitar la facilitación del desbloqueo manual (bajo la condición de que el DIP10 esté en ON); una vez que el cierre se produjo, se ejecutará una maniobra de inversión con un tiempo fijo de 0,2s para facilitar el desbloqueo manual.

FUNCIONAMIENTO DE LOS ACCESORIOS DE SEGURIDAD

FOTOCÉLULA (COM-PHOT)

DIP 4 OFF => Con la cancela cerrada, si se interpone un obstáculo delante del rayo de las fotocélulas, la cancela no abre. Durante el funcionamiento las fotocélulas intervienen tanto en apertura (restableciendo el movimiento de apertura sólo después de que las fotocélulas se liberan), como en cierre (restableciendo el movimiento inverso sólo después de que las fotocélulas se liberan).

DIP 4 ON => Con la cancela cerrada, si se interpone un obstáculo delante del rayo de las fotocélulas y se ordena la apertura, la cancela se abre (durante la apertura

55

E

S

E

S

las fotocélulas no intervendrán). Las fotocélulas intervendrán solo en fase de cierre (con restablecimiento del movimiento inverso después de un segundo aún cuando las mismas estén ocupadas).

GESTIÓN DE CIERRE INMEDIATO DESPUÉS DEL TRÁNSITO POR LAS FOTOCÉLULAS

DIP16 ON y DIP4 OFF => pasando por delante de las fotocélulas durante la apertura, la cancela se detiene y sólo después de 1 segundo de que las fotocélulas se liberan, la cancela se cierra.

DIP16 ON y DIP4 ON => pasando por delante de las fotocélulas durante la apertura, la cancela continúa abriéndose y cuando las fotocélulas se liberan, la cancela se detiene y luego de 1 segundo de pausa invierte su movimiento y comienza a cerrarse.

Si se alcanza la apertura completa (final del tiempo de apertura), se excluye el cierre inmediato y se activa el tiempo de cierre automático (si el trimmer TCA está habilitado y el led DL6 está encendido).

Si durante el cierre hay tránsito rápido (ej. peatonal) la cancela se volverá a abrir por dos segundos para después volver a cerrarse nuevamente.

DIP12 OFF => cierre inmediato deshabilitado después del tránsito por las fotocélulas

NOTA: Si recomienda comprobar el funcionamiento de las fotocélulas al menos cada 6 meses.

Una vez que los accesorios de seguridad serán reparados o vuelven a funcionar corectamente, despues de 1 segundo, en automatico, el comando paso paso y el automatico pueden funcionar normalmente; por lo tanto sea el comando radio de los transmisores y el cierre automatico pondràn funcionar como programado.

Nota 1: durante el funcionamiento a hombre presente, en caso de averìas con las costas

(o fotocelulas) las fotocelulas (o costas) trabajo mediante la interrupción de la operación en curso.

Nota 2: El pulsador de stop no es considerado una seguridad que se puede bypasar en este funcionamiento, y por lo tanto, si viene apretrado o se rompe, no permite algùn movimiento del portón.

La maniobra a hombre presente es exclusivamente una maniobra de emergencia y por lo tanto, se debe utilizar por un tiempo muy corto y con la seguridad visiva sobre el movimiento del sistema. No apenas posible, se deberà que reparar los accesorios de seguridad por un corecto funcionamiento.

INTERMITENTE

NOTA: Este cuadro electrónico puede alimentar SOLO INTERMITENTES CON CIRCUITO

INTERMITENTE (ACG7061) con lámparas de 24V y 20W máximo.

MONITORIZACIÓN COSTAS DE SEGURIDAD (A+TEST A-)

Mediante la entrada A+TEST y el DIP 12 ON es posible monitorizar la/s costa/s

La monitorización consiste en una Prueba Funcional de la costa, llevada a cabo al final de cada apertura completa de la cancela.

Después de cada apertura, el cierre de la cancela, por consiguiente, se autoriza solo si la/s costa/s han superado la Prueba Funcional.

ATENCIÓN: LA MONITORIZACIÓN DE LA ENTRADA COSTA PUEDE SER HABILITADA CON

EL DIP 12 EN ON, O DESHABILITADA CON EL DIP12 EN OFF. EN EFECTO, LA PRUEBA

FUNCIONAL DE LAS COSTAS ES POSIBLE SOLO EN EL CASO DE QUE SE TRATE DE

DISPOSITIVOS DOTADOS DE UN ALIMENTADOR DE CONTROL PROPRIO.

UNA COSTA MECÁNICA NO PUEDE SER MONITORIZADA, POR TANTO, EL DIP 12 DEBE

ESTAR COLOCADO EN POSICIÓN OFF.

FUNCIÓN PRE-INTERMITENCIA

DIP5 - OFF => el motor y el intermitente arrancan contemporáneamente.

DIP5 - ON => el intermitente arranca 3 segundos antes que el motor. EDGE (COSTA) (COM-EDGE)

Durante la apertura, si está ocupada, invierte el movimiento en cierre.

Durante el cierre, si está ocupada, invierte el movimiento en apertura.

Si permanece ocupada después de la primera actividad, ejecuta una ulterior inversión después de 2 segundos, para después ejecutar una ulterior inversión pequeña y, entonces, señalar la alarma de costa averiada u ocupada (contacto NO).

Si la costa permanece ocupada (contacto NO) cualquier movimiento es denegado.

Si no está utilizada, puentee los bornes COM-EDGE.

INDICADOR DE SEÑALIZACIÓN DE CANCELA ABIERTA (COM-SIGNAL)

Cumple la función de señalizar los estados de cancela abierta, parcialmente abierta o no del todo cerrada. Solo cuando la cancela está completamente cerrada se apaga.

Durante la programación, esta señalización está activa.

NOTA: Máx. 3 W. Si se excede con las botoneras o con las lámparas, la lógica del cuadro electrónico resultará comprometida con posible bloqueo de las operaciones.

FUNCIONAMIENTO DESPUÉS DE UN APAGÓN (SIN BATERÍAS)

Cuando regresa la tensión de red, el led DL1 se encende y queda encendido para todo el tiempo en que la puerta queda abierta. Se apagará una vez que la puerta llega en posición de cierre completo.

Se recomienda abrir completamente la cancela. Deje que la cancela se cierre por sí sola con el cierre automático o aguarde a que el intermitente deje de parpadear antes de dar una orden de cierre.

Esta operación permitirá que la cancela se realinee. De hecho, si durante el apagón los motores han sido desbloqueados y desplazados de su posición de cierre normal, la primer maniobra, cuando vuelve la alimentación, debe ser completa.

Si el apagon ocurre cuando la puerta está en movimiento, o cuando la puerta está abierta, el primer comando recibido serà el de cierre. El cierre de las dos hojas se hará con el desfase total entre las dos hoja, y por lo tanto, primero serà el Motor 2 - M2 a cerrar. Una vez que

M2 se ha apagado, el Motor 1 - M1 cerrará. Este movimiento distinto de los dos motores evitará la sopreposición de las 2 hojas.

ALARMA DE AUTOTEST COSTA (DIP 12 ON)

Al final de la apertura, si la monitorización de la costa dio resultado negativo, se acciona una alarma identificada por el intermitente que permanece encendido; bajo esta condición, el cierre de la cancela no está autorizado; solo reparando la costa y presionando uno de los mandos habilitados es posible restablecer el normal funcionamiento.

PULSADOR DE STOP (COM-STOP)

Durante cualquier operación el pulsador de STOP ejecuta la detención de la cancela.

Si se presiona con la cancela totalmente abierta (o parcialmente utilizando el mando peatonal) se excluye temporalmente el cierre automático (si está habilitado mediante el trimmer TCA y el led DL6 encendido) Por consiguiente, es necesario dar una nueva orden para volverla a cerrar.

En el ciclo sucesivo, la función de cierre automático es reactivada (si habilitada mediante trimmer TCA y led DL6 encendido)

CARACTERÍSTICAS TÉCNICAS

- Rango de temperatura

- Humedad

- Tensión de alimentación

- Frecuencia

- Alimentación batería

- Potencia Transformador

0 ÷ 55°C

< 95% sin condensación de aire

230V~ ±10% (120V/60Hz a pedido)

50/60 Hz

20-24Vdc

130VA primario 230Vac secundario 18Vac

- Absorsión máxima

- Microinterrupciones de red

50 mA

100ms

- Potencia máxima indicador de cancela abierta 24Vdc 3W (equivalente a 1 bombilla de

3W o 5 led con resistencia en serie de

- Carga máxima intermitente

2,2 k ohm)

- Corriente disponible para fotocélulas y accesorios

- Corriente disponibile en conector radio

24Vdc 20W

200mA

1A ±15%

ALARMA SENSOR DE CORRIENTE

La central T2 24V está dotada de sensores automáticos que invierten la marcha de la cancela en el caso de impactos contra cosas o personas de conformidad con las normas

EN vigentes (compruebe siempre con adecuado instrumento el respeto de los valores configurados por la norma), sin tener que efectuar particulares regulaciones en la central, en cuando gestionados por un software especial interno.

Si después de una primera intervención del sensor de corriente en apertura o cierre (solo a alta velocidad) se tiene una segunda intervención, obviamente en sentido contrario, la cancela se detiene y, entonces, invierte por 1 segundo.

El estado de alarma será visualizado por el intermitente que permanecerá activo durante

1 minuto. Durante este tiempo es posible restablecer el funcionamiento de la cancela presionando cualquier pulsador de mando.

CARACTERÍSTICAS TÉCNICAS RADIO (modelo T2 24V crx)

- Frecuencia Recepción

- Impedancia

- Sensibilidad

- Tiempo excitación

- Tiempo desexcitación

433,92MHz

52 OHM

2-24 µV

300ms

300ms

FUNCIONAMIENTO A HOMBRE PRESENTE EN CASO DE AVERÍAS CON LOS ACCESORIOS

DE SEGURIDAD

Si el burlete de seguridad está estropeado o se queda apretado por mas de 5 segundos, o, si la fotocelula de seguridad se estropea o se queda empeñada por mas de 60 segundos, los comandos ABRE, CIERRE, K BUTTON y el PEATONAL, funcionaràn solo a hombre presente.

El signal de activación de este funcionamiento serà indicado por el LED de programacion que relampaguea.

En este funciòn, será aconsentido el apertura y el cierre solo manteniendo apretados los pulsadores de comandos. El comando radio y el cierre automatico seràn excludidos porque estas formas de funcionamientos no son permitidas por las normas.

56

- Todas las entradas deben ser utilizadas como contactos limpios porque la alimentación se genera internamente (tensión segura) en la tarjeta y está dispuesta de modo tal que garantice el respeto de aislación doble o reforzada respecto de las partes bajo tensión peligrosa.

- Los posibles circuitos externos conectados a las salidas del cuadro electrónico deben efectuarse de manera tal que garanticen el aislamiento doble o reforzado respecto de las partes bajo tensión peligrosa.

- Todas las entradas son gestionadas por un circuito integrado programado que ejecuta un autocontrol en cada puesta en marcha.

RESOLUCIÓN DE PROBLEMAS

Después de haber efectuado todas las conexiones siguiendo atentamente el esquema y haber posicionado el portón en posición intermedia, verifique el correcto encendido de los led rojos

DL7, DL8 y DL9.

En caso de falta de encendido de los led, siempre con el portón en posición intermedia, verifique lo que sigue y sustituya eventuales componentes averiados.

DL7 apagado Fotocélulas averiadas

DL8 apagado Borde de seguridad averiado (En caso que el borde no este conectado, realice el puente entre COM y EDGE)

DL9 apagado Pulsador de Stop averiado (en caso de que el Stop no esté conectado, realice un puente entre COM y STOP)

Durante el funcionamiento con hombre presente, con DIP N° 1 en ON, verifique que durante la apertura de M1 y M2 se enciendan los led verdes DL2 y DL4 y que durante el cierre de M1 y M2 se enciendan los led rojos DL3 y DL5.

De lo contrario, invierta los cables del motor interesado.

DEFECTO

Después de haber efectuado varias conexiones y haber dado tensión, todos los led están apagados.

SOLUCIÓN

Verifique la integridad de los fusibles F1, FUSE 1

En caso de fusible interrumpido, utilice únicamente uno de valor adecuado.

F1 T 2A FUSIBLE DE PROTECCIÓN TRANSFORMADOR (externo a la tarjeta T2 24V)

FUSE 1 8A FUSIBLE DE PROTECCIÓN DE MOTORES

El motor abre y cierra, pero no tiene fuerza y se mueve lentamente.

Verifique regulación trimmers RUN y LOW-SPEED.

El portón ejecuta la apertura, pero no cierra después del tiempo configurado.

Asegúrese de que el trimmer TCA esté habilitado con el led DL6 encendido.

Pulsador OPEN siempre activo, sustituya el pulsador o el switch del mando OPEN

Autotest de la costa fallido, verifique las conexiones entre el cuadro electrónico y el alimentador para las costas.

Atención: si no se está ultilizando un alimentador para las costas, el DIP 12 debe estar colocado en posición OFF.

El portón no abre y no cierra accionando los pulsadores K, Radio, Open y Close.

Contacto costa de seguridad averiado. Contacto fotocélulas averiado con DIP 4 OFF. Arregle o sustituya el correspondiente contacto.

El cierre eléctrico no funciona.

Asegúrese de haber habilitado el DIP 8 en ON.

El led DL1 parpadea rápidamente y no se habilita ningún movimiento.

Coloque los dip switch 1,2 o 3 en posición OFF.

E

S

OPCIONALES -

Para las conexiones y datos técnicos de los accesorios, consultar los manuales respectivos.

TARJETA DE CARGA BATERÍA

PESTILLO MECANICO

BATERÍA

Batería 2,2Ah 12V

cód. ACG4648

Pestillo mecanico para cancelas de 2 hojas.

CERRADURA ELÉCTRICA

cód. ACG5000 cód. ACG9515

57

Cerradura Horizontal - izquierda vista externa - 12Vac

Serratura Verticale - 12Vac

Cerradura Vertical - 12Vac cód. ACG8670 cód. ACG8650 cód. ACG8650

E

S

T2 24V Wi-Fi

Cuadro con sensores de impacto y tarjeta MASTER Wi-Fi.

Con contenedor. cód. ABT2025W

DISPOSITIVOS Wi-Fi

MASTER Wi-Fi

FICHA DE GESTIÓN SISTEMA SIN CABLES con enchufe - 12÷30V ac/dc con regleta - 12÷30V ac/dc

NOVA Wi-Fi

cód. ACG6094 cód. ACG6099

VERTIGO Wi-Fi

FOTOCÉLULAS SIN CABLES

PAR DE COLUMNAS NOVA

BLOCK Wi-Fi

cód. ACG8037 cód. ACG8039

FOTOCÉLULAS SIN CABLES PARA REMPLAZAR A LA COSTA

VERTIGO Wi-Fi 8 cód. ACG8042 - VERTIGO Wi-Fi 10 cód. ACG8043

SPARK Wi-Fi

SELECTOR DE LLAVE SIN CABLES cód. ACG6098

58

INTERMITENTE SIN CABLES

SOPORTE LATERAL cód. ACG7064 cód. ACG7042

®

R.I.B. S.r.l.

25014 Castenedolo - Brescia - Italy

Via Matteotti, 162

Tel. ++39.030.2135811

Fax ++39.030.21358279 - 21358278 www.ribind.it - [email protected]

AZIENDA CON SISTEMA

DI QUALITÀ CERTIFICATO

DA DNV

COMPANY WITH QUALITY

SYSTEM CERTIFIED

BY DNV

DICHIARAZIONE DI CONFORMITÁ - DECLARATION OF COMPLIANCE

DÉCLARATION DE CONFORMITÉ - ÜBEREINSTIMMNUGSERKLÄRUNG

DECLARACIÓN DE CONFORMIDAD

Dichiariamo sotto la nostra responsabilità che l’operatore PRINCE 24V è conforme alle seguenti norme e Direttive:

L’opérateur PRINCE 24V se conforme aux normes suivantes:

We declare under our responsibility that PRINCE 24V operator is conform to the following standards:

Wir erklaeren das der PRINCE 24V den folgenden EN-Normen entspricht:

Declaramos bajo nuestra responsabilidad que los operators PRINCE 24V es conforme a la siguientes normas y disposiciones:

EN 55014-1

EN 55014-2

2012

2015

EN 60335-1 2016

EN 60335-2-103 2010

EN 61000-3-2

EN 61000-3-3

EN 61000-6-1

EN 61000-6-2

2015

2014

2007

2006

EN 61000-6-3

EN 61000-6-4

2013

2013

Inoltre permette un’installazione a Norme - Permit, en plus, une installation selon les normes suivants

You can also install according to the following rules - Desweiteren genehmigt es eine Installation der folgenden Normen:

Además permite una instalación según las Normas:

EN 12453 2011 2002 EN 12445 2002 EN 13241-1

Come richiesto dalle seguenti Direttive - Conformément aux Directives

As is provided by the following Directives - Wie es die folgenden Richtlinien verfügen

Tal y como requerido por las siguientes Disposiciones:

2006/95/CE 2004/108/CE

Il presente prodotto non può funzionare in modo indipendente ed è destinato ad essere incorporato in un impianto costituito da ulteriori elementi. Rientra perciò nell’Art. 6 paragrafo 2 della

Direttiva 2006/42/CE (Macchine) e successive modifiche, per cui segnaliamo il divieto di messa in servizio prima che l’impianto sia stato dichiarato conforme alle disposizioni della Direttiva.

Le présent dispositif ne peut fonctionner de manière indépendante, étant prévu pour être intégré à une installation constituée d’autres éléments. Aussi rentre-t-il dans le champ d’application de l’art. 6, paragraphe 2 de la Directive machines 2006/42/CEE et de ses modifications successives. Sa mise en service est interdite avant que l’installation ait été déclarée conforme aux dispositions prévues par la Directive.

This product can not work alone and was designed to be fitted into a system made up of various other elements. Hence, it falls within Article 6, Paragraph 2 of the

EC-Directive 2006/42

(Machines) and following modifications, to which respect we point out the ban on its putting into service before being found compliant with what is provided by the Directive.

Dieses Produkt kann nicht allein funktionieren und wurde konstruiert, um in einen von anderen Bestandteilen zusammengesetzten System eingebaut zu werden. Das Produkt fällt deswegen unter Artikel 6, Paragraph 2 der EWG-Richtlinie 2006/42 (Maschinen) und folgenden.

Este producto no puede funcionar de manera independiente y se tiene que incorporar en una instalación compuesta por otros elementos. Está incluido por lo tanto en el Art. 6 párrafo 2 de la Disposición 2006/42/CEE (Maquinaria) y sus siguientes modificaciones, por lo cual destacamos que está prohibido poner la instalación en marcha antes de que esté declarada conforme a la citada Disposición.

Legal Representative

(Rasconi Antonio)

59

PRINCE 24V

ACG1083

BA01046

BA01076

CAL1158

CPL1164

DTM10X40I

CMO1286

CME6085

CPL1165

CTC1253

CPL1163

CRS6204R

CME2125

CTC1116

CTC1269

CME9056

DAC4X14

DRD4

CPL1127

DRL10X20I

DDD10MAI

ACG8088

CAL1157

DAC29X95

CPL1167

CEL1457

DTB55X40

Codice Denominazione Particolare

ACG1083 Chiave di sblocco

ACG8088 Fermo meccanico in chiusura PRINCE

BA01046

BA01076

Serie access. cilind. PRINCE

Sacch. access. PRINCE

CAL1157

CAL1158

CCA1263

CCA1351

Semiguscio inferiore

Semiguscio superiore

Gruppo Forcella - Perno

Piastra cancello

CEL1457 Blocca cavo

CME5235 Chiocciola bronzo

CME6085 Forcella posteriore

CME2125 Boccola vite senza fine

CME9056 Vite s/fine

CMO1286 Mot. PRINCE EPIC.MBT 24V

CPL1127

CPL1163

Supporto motore 24V-230W

Innesto-2 Prince

CPL1164

CPL1165

Innesto-1 PRINCE

Mozzo sblocco PRINCE

CPL1167 Piastra morsettiera

CRS62042R Cusc. 6204/2RS

CTC1116 Seeger E12

CTC1253

CTC1269

Molla ritorno sblocco

Spina CIL. 5X30 non temprata

CVA1176 Boccola 12X16X12 bronzo F7/R7

DAC29X95 Vite aut.TC.CR. 2.9X9.5 zincat

DAC4x14 Vite aut.TC.CR. 4X14

DAE55X16 Vite aut. TC.TE 5.5x16 P.TRINCA Z

DDD8MAI Dado autob. 8MA INOX

DDD10MAI Dado autob. 10MA INOX alto

DRL4X10Z Rond. Piana 4x10

DRL10X20I Rond. Piana 10X20 INOX

DRL10X30I Rond. Piana 10X30 INOX

DTB55X40 Vite TCEI 5,5X38 autof. zinc.

DTE8X30I Vite TE8X30 INOX UNI 5739

DTE10X20I Vite TE10X20 INOX

DTM10X40I Vite TE 10X40 INOX UNI 5737

CCA1263

CME5235

CVA1176

CCA1351

DRL10X30I

DTE10X20I

Questo prodotto è stato completamente progettato e costruito in Italia · Ce produit a été complètement développé et fabriqué en Italie · This product has been completely developed and built in Italy · Dieses Produkt wurde komplett in Italien entwickelt und hergestellt · Artìculo totalmente proyectado y producido en Italia

®

25014 CASTENEDOLO (BS) - ITALY

Via Matteotti, 162

Tel. +39.030.2135811

Fax +39.030.21358279

www.ribind.it - [email protected]

advertisement

Was this manual useful for you? Yes No
Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project

Related manuals

Download PDF

advertisement