Premium Complete Rework Station with Electric Pump

Premium Complete Rework Station with Electric Pump
www.jbctools.com
English
3
Español
35
Premium
Complete Rework Station
with Electric Pump
Ref. RMSE-C
Page
w w w.jbctools.com
Index
Packing List
The following items should be included:
Packing list ......................................................... 3
JT Hot Air station
Features ..............................................................7
Stand & Nozzle changer ................................8
Protectors & Extractors ................................10
T260 Pick & Place ..........................................11
Operation & Process Control with JT .......12
JT-TA Replacing the Heating Element ......15
JT-TA Changing the Heater Hose Set ......15
DDE Control Unit & MSE Module
Features ............................................................16
Stands & Tip Cleaner ....................................18
T245 Changing Cartridges ..........................20
DR560 Changing Tips ..................................21
DR560 Changing the Heating Element ...22
DR560 Tin Deposit Cleaning ......................23
DR560 Tip Care ..............................................24
Desoldering Process DDE & MSE .............24
MSE Initial Setup ............................................25
MSE Changing the pump filters .................25
Operation with DDE ......................................26
Process Analysis ............................................28
Soldering Net ..................................................29
Working with robots ......................................30
Station Sotware ..............................................30
JTE Control Unit ........... 1 unit
Ref. JTE-1D (120V)
JTE-2D (230V)
JTE-9D (100V)
DDE Control Unit .......... 1 unit
Ref. DDE-1B (120V)
DDE-2B (230V)
DDE-9B (100V)
Electric Desoldering
Module ............................ 1 unit
Ref. MSE-A
Stand ................................ 1 unit
Ref. JT-SD
Stand ................................ 1 unit
Ref. AD-SD
Stand ............................... 1 unit
Ref. DR-SD
Heater hose set ............ 1 unit
Ref. JT-T1A (100V / 120V)
JT-T2A (230V)
General Purpose
Handle ............................... 1 unit
Ref. T245-A
Desoldering Iron ........... 1 unit
Ref. DR560-A
C560003 already inserted
Maintenance .....................................................31
Safety ...................................................................32
Specifications ..................................................33
Exploded View .................................................66
2
3
w w w.jbctools.com
DR560 Accessories
Ref. 0010211
JT Accessory set
Ref. 0012332
Extractor stand* ............ 1 unit
Ref. 0008752
Tip Cleaner ..................... 1 unit
Ref. CL9885
Extractors*
Ref. E2184
E2064
E2052
Tripod*
Ref. T2050 (Ø 39mm)
T2250 (Ø 85mm)
Protectors*
Ref. P2220
P2230
P2235
P4000
P4010
Suction Tube*
Ref. 0932330
Suction Cups*
Ref. 0930110
Ø 10 - 0934050 (x3)
Ø 4.7 - 0934070 (x1)
Nozzles
Ref. JN2015 (x1)
JN2012 (x1)
JN2020 (x1)
Tip cleaning set .......................................... 1 unit
Ref. 0965970
Long Tip Cleaning set ........................... 1 unit
Ref. 0965760
Tips ............................. 3 units
Ref. C560005
Ref. C560013
Ref. C560004
Tin deposit .................... 1 unit
Ref. 0812620
Spanner ...........................1 unit
Ref. 0780550
Filter Box .................... 1 unit
Ref. 0780840
Internal gasket ............ 2 units
Ref. 0812360
Metal tin diposit ........... 1 unit
Ref. 0812630
Cotton Filter ................... 1 unit
Ref. 0781046
Filter Box ..........................1 unit
Ref. 0005966
Suction Filter ...................1 unit
Ref. 0821830
It contains 10 filters
It contains 50 filters
It contains
10 filters
Cartridges ..................... 2 units
Ref. C245903
Ref. C245906
Sponge ............................. 1 unit
Ref. S0354
Metal Brush .................... 1 unit
Ref. CL6217
* These accessories are not supplied with JT-2QC / JT-1QC / JT-9QC stations.
4
5
w w w.jbctools.com
JT Features
Pick & Place ................... 1 unit
Ref. T260-A
Bent Needles Set ......... 1 unit
Ref. 0861660
Straight Needles Set ... 1 unit
Ref. 0901546
USB-B connector
Update the station
software from
the JBC website
Cups Set ......................... 1 unit
Ref. 0940163
Cleaning stick ................1 unit
Ref. 0786640
Activates the
suction pump
Heating
element
Stand Cable ................. 2 units
Ref. 0011283
Module Cable ................. 1 unit
Ref. 0014874
Union Flanges ............... 1 unit
Ref. 0011356
Heater Hose set
Ref. JT-T1A (100V/120V)
JT-T2A (230V)
Suction Tube
Ref. 0932330
For tripods
and extractors
Hot Air button
(On / Off)
Another connectable tool:
Precision Heater hose set
Ref: TE-TB
Power cords
For DDE ........................... 1 unit
Ref. 0013671 (100/120V)
0010569 (230V)
For JTE ............................. 1 unit
Ref. 0009417 (100V/120V)
0009401 (230V)
Manual ...............................1 unit
Ref. 0017357
w w w.jbctools.com
Stand
Ref. JT-SD
Optional:
P-005 Pedal
connection
Power Socket
Premium
Complete Rework Station
with Electric Pump
Ref. RMSE-C
6
Fuse
Equipotential
connection
7
w w w.jbctools.com
Adjustable Stand
Quick Nozzle Changer
Adjust the tool holder angle to suit your work position.
Changing nozzles quickly and safely.
2
1
Turn the tool off
and handle with
care. The heating
element and the
nozzle are still hot.
Operation Modes
1. From the main Menu, select the mode to activate the tool depending on the task.
Compatible Nozzles
Stand + Autostart OFF
Press
Press the start/stop button to
blow hot air.
Stand + Autostart ON
Do not
press
The tool automatically starts
blowing hot air when lifted
from the stand.
2. The tool stops blowing hot air when returned to the stand.
8
Pedal*
Press
Press the Pedal to blow hot
air and release to stop.
*The P-005 Pedal is not
supplied with this station.
See our website.
The JT-TA works with JT nozzles. Find the model that best suits your soldering needs in www.jbctools.com
Straight
Bent
Flat
Ref.
Shape
Size
Ø mm
Ø mm
A x B mm
JN2020
Straight
Ø 8mm
JN8417
Straight
Ø 10mm
JN2015
Bent
Ø 4mm
JN2012
Bent
Ø 6mm
JN6633
Bent
Ø 8mm
JN7637
Flat
10 x 2mm
JN7638
Flat
20 x 2mm
JN7639
Flat
30 x 2mm
In case of a loosely fitting nozzle:
1. Push the nozzle tab inwards with a
screwdriver or flat-nosed pliers.
2. Insert the nozzle into the JT-TA Heater again.
9
w w w.jbctools.com
Protectors & Extractors
T260 Pick & Place
For large components (fig. 3 and 4).
For small components (fig. 1 and 2).
We recommend using the protector + tripod
1
This tool helps place and remove SMDs of any size thanks to the suction provided by the station.
We recommend using the extractors
2
3
4
Press the button to
start/stop the suction
Pick & Place
Ref. T260-A
Protectors
* Ref. AxB (mm)
Extractors
* Ref. AxB (mm)
* Ref. AxB (mm)
P3353 4,3 x 3
48 P2230 15 x 15
52 E2052 20 X 20
P3786 5,2 x 5,2
60 P4010 17 x 17
64 E2064 20 X 26
P3352 5,2 x 7,5
P4005 18 x 29
80 E2184 24 X 24
P3355 5,2 x 9,5
P4030 18,5 x 18,5
E2068 27 X 27
P3356 6,2 x 4,2
P1068 18,5 x 24
E4020 28,5 X 28,5
P3785 7,2 x 7,2
P2685 28,5 x 28,5
E4015 31,5 X 31,5
P3784 8,2 x 8,2
P4085 31,5 x 31,5
E2084 33 X 33
E2100 38 X 38
P4035 9 x 13
P2672 33 x 46
P4040 9,5 x 19
P4002 50 x 50
P4080 9,5 x 21
P3357 52,5 x 14
32 P2220 10 x 10
P4045 10,5 x 21
P4090 11 x 16
24 P2235 12 x 17
* Ref. AxB (mm)
Choose the suction cup that best fits the component (Maximum working temp.: 250ºC / 482ºF):
E2124 45 X 45
Insert the needle
with the appropriate
cup for a correct
suction process.
You should avoid the
needle to stick out of
the lower part.
Operation
Tripods
* Ref. øC (mm)
T2050 39
T2250 85
P1249 12 x 23
44 P4000 12,5 x 12,5
1. Suction
2. Release
Once activated
the suction button,
cover the pen hole
with your finger and
pick the component.
Lift your finger
to release the
component on the
appropriate place.
P3354 13,2 x 13,2
P4025 13,5 x 21,5
* Reference Desk
Manual extractor
* Ref. øD (mm)
E2190 7
øD
10
11
w w w.jbctools.com
Operation with JT station
1. Placing
Program Mode
2. Heating
3. Releasing
ºC
Graph of selected
program
Position the extractor with the
appropriate suction cup and
press the suction button.
Heat the component.
The component lifts off
automatically when the
solder melts.
Program 8
Selected program
T e m p ºC
380
Air
100%
Time 125s.
Decrease program
number
Current temperature
Selected air flow
Remaining time
Increase program
number
Program Options
Process Control
Edit Program
This option allows you to edit or create a program.
First, you must select the program to edit and then modify the points that make up the program.
Each program is composed of 9 points, each point consisting of 3 parameters:
1. Time (seconds)
2. Temperature (°C / °F)
3. Flow rate (%)
Manual Mode
Time to stop
T e m p ºC
Current temperature
Selected temperature
45 seconds
Air %
400 85
Current air flow
It should be taken into account that the regulation range permitted by the station is 150-450°C, whereby it is not possible to create temperature ramps between room temperature (Toff) and 150°C.
400ºC Select
Power 70%
% Instant power supplied
to heater
Access Menu (pess key 2 seconds) & Confirm Selection
You can switch between operating modes (Manual Mode / Program Mode) by pressing the
“increase” and “decrease” keys simultaneously for 2 seconds (Only when programs mode is ON).
12
You can delete the last point of the program by selecting “-----” in the time parameter.
The station can store up to 25 temperature programs.
The first three programs are edited by JBC as an example.
Copy Program
This option allows you to copy a program.
You must select the program source and its destination (where it will be copied).
Delete Program
This option will allow you to delete a previously selected program.
13
w w w.jbctools.com
JT-TA Replacing the Heating Element
Menu Screen
Only perform this operation when the element is cold and the unit is disconnected from the mains.
Original PIN: 0105
1. Loosen the screw.
2. Pull the heating element away from the handle.
3. Connect the new heating element, ensuring its pushed all the way in.
4. Tighten the screw.
Main menu
1
2
3
4
Reset station
Station Settings
Program Settings
Counters
Heating Element
Ref. 0014107 (230V)
0014105 (100V / 120V)
5 Program version
Exit
Station Settings
Program Settings
1
2
3
4
Temp unit
Celsius
Maximum temp 4500C
Minimum temp
T OFF
Fix temp
-----
5
6
7
8
Temp Adjust
Max air
Min air
Fix air
+ 00C
100%
10%
-----
9 Time to stop
10 Stand/Pedal
Autostart
11 Beep
120 sec
Stand
OFF
ON
12 Pop up
13 Change PIN
1
2
3
4
ºC
Programs OFF
Edit program
Copy program
Delete program
ºC
Back
* Selecting Minimum Temp as
“T OFF”, the air blows at room
temperature.
Heating Hose Set
Ref. JT-T1A (100V / 120V)
JT-T2A (230V)
Edit Program
Select
Program
1
ON
Handle
Ref. JT-A
Edit Program 1
Step
1
Time
30
Temp 300
Air
100
Exit
JT-TA Changing the Heater Hose Set
1. Ensure that the tool is turned off.
2. Use a spanner to unscrew the connecting nut.
3. The tube end of the new heater must be inserted
so that the longitudinal rib fits into the groove.
5. Follow the same steps conversely.
Counters
1
2
3
Station ON hours
Works hours
Works cycles
0
0
0
Back
14
15
w w w.jbctools.com
DDE & MSE Features
Work simultaneously with up to 2 tools and join each station port with 1 module + 1 pedal (Peripherals).
2,8” Color TFT screen
Stand Cable
Ref. 0011283
USB-A connector
Equipotential connection
USB-B connector
RJ12 connector for Robot
Tilt the display
for easy reading
Power Socket
Cartridge
Ref. C245903
Ref. C245906
General
Purpose
Handle
Ref. T245-A
Tip
Ref. C560004
Ref. C560005
Ref. C560013
Desoldering Iron
Ref. DR560-A
Module Cable
Ref. 0014874
Electric Desoldering Module
Ref. MSE-A
To another peripheral
To Pedal
Ref. P-005
Stand
Ref. AD-SD
16
Stand
Ref. DR-SD
Suction Filter
Ref. 0821830
17
w w w.jbctools.com
Adjustable Stands
Tip Cleaner
Improve thermal transfer by cleaning the tip after each solder joint.
Cable collector
Keeps working area free of cable.
Brass wool
Ref. CL6210
Very effective cleaning
method. It leaves a small layer
of solder on the tip to prevent
oxidation between cleaning
and rewetting.
Quick tip changer
Permits switching
cartridges without
interrupting
your work.
Quick tip changer
Holding tip system
for easy change.
Splashguard
It prevents splashing of
solder particles when
using the brass wool.
Non-slip base
Heavy weighted nonslip base for simplehanded cleaning.
Wiper
Ref. CL0236
A temperature resistant receptacle lets
the operator remove excess solder by
gentle tapping or wiping. It can be easily
removed for cleaning.
Stand
Ref. AD-SD
Sponge
Ref. S0354
The least harmful cleaning
method. Keep the sponge damp
with distilled water when working
to avoid tip wear.
Stand
Ref. DR-SD
Tapping:
Wiping:
Tap gently to remove
excess solder.
Use the slots to
remove remaining
particles.
Optional
Adjustable
tool holder
Suits your
work
position.
18
Adjustable
cable
collector
Inox wool
Ref. CL6205
Brushes
Ref. CL6220
Tip-tinner
Ref. TT-A
Sand
Ref. CL6211
19
w w w.jbctools.com
T245 Changing Cartridges
DR560 Changing Tips
Save time and change cartridges safely without switching the station off.
This operation should be done while the tip is hot, not below 250°C, so that any tin left inside is in
molten state.
1. Removing
2. Inserting
3. Fixing
250ºC minimum
1. Removing
C
D
B
Unscrew the tip using the spanner
supplied.
A
2. Inserting
Fit the new tip and tighten with the
spanner to make sure it is air tight.
Place the handle in the
extractor and pull to
remove the cartridge.
Place the handle on top of
the new cartridge and press
down slightly.
Use the holes for fixing the
cartridge* as follows:
A. For straight C210.
B. For curved C210.
C. For curved C245.
D. For straight C245.
Compatible Tips
The DR560 works with C560 tips. Find the model that best suits your soldering needs in www.jbctools.com
Here are some C560 tips in real size (mm):
*Important
It is essential to insert the cartridges as far as the mark for a proper connection.
Aø
Bø
C560-001
Mark
ØA=1,4 ØB=0,6 Ømax. pin=0,4
C560-002
C560-001
ØA=1,8 ØB=0,8 Ømax. pin=0,6
C560-002
Compatible cartridges
The T245 handle works with C245 cartridges. Find the model that best suits your soldering needs
ø 3,5
ø1
in www.jbctools.com
ø 1,5
C560-014
ØA=2,5 ØB=0,8 Ømax. pin=0,6
C560-003
C560-003
C560-014
C560-004
A
Round
20
Chisel
Round bent
Bevel
A
B
ØA=3,2 ØB=1,3 Ømax. pin=1,1
C560-004
ØA=2,7 ØB=1 Ømax. pin=0,8
C560-009
ØA=5 ØB=1,3 Ømax. pin=1,1
C560-009
Special models
21
w w w.jbctools.com
DR560 Changing the Heating Element
DR560 Tin Deposit Cleaning
To perform this operation, turn off the station or disconnect the tool.
1. Removing the lid
2. Cleaning
1. Loosening
The deposit lid needs to be
loosened.
Check
internal joint
2
2. Removing
Loosen the screw as shown
and remove the
Heating Element.
1
Remove the coil to clean the inside of the
deposit with the stick supplied.
3. Placing
Place the new Heating
Element and follow the steps
conversely.
Check filter
3
Lid
Important
For a proper connection it is essential to insert the cartridge by lining it up to the mark
.
The lid must be removed with the DR560 in
vertical position.
The filter and internal joint must be checked
and replaced if dirty or damaged.
3. Inserting the deposit
The deposit must be inserted with coil filter in
place, positioned between the 2 lines marked
on the tin deposit.
Then the whole unit must be closed by
screwing the lid.
22
Marks
23
w w w.jbctools.com
DR560 Tip Care
MSE Initial Setup
The intake tube should be periodically cleaned by the largest rod.
After connecting the electric desoldering module (MSE-A), enter the Peripherals
Menu and select the port which you want to join with the module.
Peripherals
17:14
1. Select the module from the list of
peripheral connections. Remember your first
connection is denoted as “a”, the second
being “b”, etc. (e.g. MSE_a, MSE_b,...)
Important
DO NOT press the vacuum pump button while tinning the desoldering tip, as the fumes given
off by the flux would quickly block the ducts and the air filter.
Desoldering process
2. Press Menu or Back to save changes.
Once set up, you can change the module
settings by entering the Peripherals Menu.
Peripherals
Pedal
Module
Port 2-DR
Module
MSE_a
None
None
None
MSE Changing the pump filters
Use a tip with a larger diameter than the pad to achieve maximum aspiration and thermal efficiency.
1. Placing
2. Rotating
3. Aspirating
- Clean the casing with a damp cloth. Make sure to use a soft cloth when cleaning the front.
- Periodically check all cable and tube connections.
- Keep filters clean to ensure proper solder suction and replace them when necessary.
Important
Do not use sharp
pointed objects
to open the
suction filter.
Place the tip with the
component terminal in the
hole.
When the solder liquefies,
gently rotate the tip so that
the compo­nent terminal can
be lifted off.
Press the vacuum pump
button long enough to remove
the solder.
After pressing the desoldering key there is a slight delay until the self-contained vacuum pump
stops. This makes sure that the vacuum circuit is completely empty. If any solder remains are left
on a terminal after desoldering it, resolder it with fresh solder and repeat the desoldering operation.
24
Suction filter
Ref. 0821830
Cotton filters
Ref. 0781046
O Ring
Ref. 0007717
Filter cover
Ref. 0004710
Spare filters
Ref. 0005966
25
w w w.jbctools.com
Operation
Work Screen
The JBC Exclusive Heating System
The DDE offers an intuitive user interface which provides quick access to station parameters.
Our revolutionary technology is able to recover tip temperature extremely quickly. It means the user
can work at a lower temperature and improve the quality of soldering. The tip temperature is further
reduced thanks to the Sleep and Hibernation modes which increase the tip life by 5.
Status bar
1. Work
2. Sleep
17:14
3. Hibernation
Tool
in use
T245
350
Power
indicator
Long time in
the stand
When the tool is lifted from the
stand the tip will heat up to the
selected temperature.
When the tool is in the stand,
the temperature falls to the
preset Sleep temperature.
17:14
17:14
T245
350
ºC
Tool in the stand
250
Port
2
380
Port
2
Station
Information
Change
port
System notifications (Status Bar)
USB flash drive is connected.
Actual Temp. 25ºC
Station is controlled by a PC.
Actual Temp. 180ºC
Delay to hibernation: 29:30
350
Hibernation
Port
2
Station is controlled by a robot.
Port
2
Station
Tools Menu:
Tools Menu:
Tools Menu:
· Set temperature limits
· Select temperature levels
· Set Sleep temperature
· Set Sleep delay
(from 0 to 9 min or no Sleep)
· Set Hibernation delay
(from 0 to 60 min or no
hibernation)
Tools
Counters
Station software update.
Press INFO to start the process.
Warning.
Press INFO for failure description.
Peripherals
26
Power
45%
Displayed if
temperature
levels are
activated
Press INFO for each parameter description.
T245
Sleep
Temp. Levels
Menu Options
17:14
T245
Selected 350ºC
Power
45%
After longer periods of
inactivity, the power is cut off
and the tool cools down to
room temperature.
ºC
Graphics
Reset
Error. Press INFO for failure description,
the type of error and how to proceed.
27
w w w.jbctools.com
Soldering Net
Process analysis
By pressing Graphics in the main MENU, temperature and power figures in real
time are displayed for each port. This helps you decide which tip to use to obtain
the best quality solder joints.
Graphics
1. Download the JBC Manager software and the user manual from www.jbctools.com/manager.html
2. Connect the stations via USB-B connector and the PC will automatically detect them.
3. The notification
will be displayed on the station.
Functions:
- Set all the station parameters from your PC.
- Organize groups of stations and set all their parameters at the same time.
- Store specific configurations for later uses.
- Analyze the soldering graphics of the stations on your PC and export them.
17:14
450
400
Power (%)
Remotely manage and monitor as many stations as your PC can handle.
350
300
250
200
Temperature
150
100
JBC
Manager
software
50
Power
Temp
Port 1 - T245
See other
port graphic
USB Hub
Export graphics
Insert a USB flash drive into the USB-A
connector to save your soldering process in
csv format.
28
any JBC
station
29
w w w.jbctools.com
Working with Robots
Maintenance
Manage and monitor the station using a Robotic system.
Before carrying out maintenance or storage, always allow the equipment to cool.
1. Connect the tool to the station port by means of the CHB-A Converter.
2. Connect your Robot system to the Robot connector (RJ12) of the station.
DB9-RJ12 Adapater available only if necessary (Ref: 0013772).
3. Enable the Robot option in the station settings and the notification will be displayed:
4. Set your Robot’s commands according to the Robot Communication Protocol, available on the
website www.jbctools.com/jbcsoftware-menu-115.html.
- Clean the station screen with a glass cleaner
or a damp cloth.
- Periodically check that the metal parts of
the tool and stand are clean so that the
station can detect the tool status.
CHB-A
Converter
Ref. CHB-A
Robot
- Use a damp cloth to clean the casing and
the tool. Alcohol can only be used to clean
the metal parts.
Clean periodically
- Maintain tip surface clean and tinned prior
to storage in order to avoid tip oxidation.
Rusty and dirty surfaces reduce heat
transfer to the solder joint.
Control
Unit
RS-232
connection
- Periodically check all cables and tubes.
- Replace a blown fuse as follows:
Fuse
Update the station software
1. Download the JBC Update File from
www.jbctools.com/software.html and save
it on a USB flash drive. Preferably one with
no other files.
JBC
Update File
2. Insert the USB flash drive to the station.
The icon
is diplayed while updating.
Fuse holder
Fuse holder
1. Pull off the fuse holder and remove the fuse. If necessary use a tool to lever it off.
2. Press the new fuse into the fuse holder and replace it in the station.
- Replace any defective or damaged pieces. Use original JBC spare parts only.
- Repairs should only be performed by a JBC authorized technical service.
30
31
w w w.jbctools.com
Safety
Specifications
It is imperative to follow safety guidelines to prevent electric
shock, injury, fire or explosion.
- Do not use the units for any purpose other than soldering or rework. Incorrect use may cause fire.
- The power cord must be plugged into approved bases. Be sure that it is properly grounded
before use. When unplugging it, hold the plug, not the wire.
- Do not work on electrically live parts.
- The tool should be placed in the stand when not in use in order to activate the sleep mode.
The soldering tip, the metal part of the tool and the stand may still be hot even when the station is turned off. Handle with care, including when adjusting the stand position.
- Do not leave the appliance unattended when it is on.
- Do not cover the ventilation grills. Heat can cause inflamable products to ignite.
- Use a “non residue” classified flux and avoid contact with skin or eyes to prevent irritation.
- Be careful with the fumes produced when soldering.
- Keep your workplace clean and tidy. Wear appropriate protective glasses and gloves when working to avoid personal harm.
- Utmost care must be taken with liquid tin waste which can cause burns.
- This appliance can be used by children over the age of eight and also persons with reduced
physical, sensory or mental capabilities or lack of experience provided that they have been given adequate supervision or instruction concerning use of the appliance and understand the hazards involved. Children must not play with the appliance.
Complete Rework station with Electric Pump
RMSE-1C / RMSE-2C / RMSE-9C
- Total weight: 16.6 kg (36.6 lb)
- Ambient Operating Temperature: 10 to 40ºC (50-104ºF)
JTE-1D 120V 50/60Hz. Input fuse 8A. Rated current: 6A.
JTE-2D 230V 50/60Hz. Input fuse 4A. Rated current: 3A.
JTE-9D 100V 50/60Hz. Input fuse 8A. Rated current: 7A.
- Weight: 3.9 kg (8.5 lb)
- Dimensions: 148 x 184 x 140
- Nominal Power: 700W
- Temperature selection: Room temperature / 150ºC to 450°C (300ºF to 840ºF)
Cool mode: T Off. Used to blow air at room temperature
- Ambient Operating Temperature: 10 to 40ºC (50-104ºF)
- Air flow regulation: 10-50 SLPM
- Vacuum: 30% / 228 mmHg / 9 inHg
- USB connector station-PC
- P-005 Pedal Connection
DDE-1B 120V 50/60Hz. Input fuse: 4A. Output: 23.5V
DDE-2B 230V 50/60Hz. Input fuse: 2A. Output: 23.5V
DDE-9B 100V 50/60Hz. Input fuse: 5A. Output: 23.5V
- Weight: 4.3 Kg (9.3 lb)
- Dimensions: 148 x 120 x 232 mm
- Output Peak Power: 150W per tool
- Temperature Range: 90-450°C (190-840 ºF)
- Idle Temp. Stability (still air) ±1.5 ºC (±3 ºF)
- Tip to ground resistance: <2 ohms
- Tip to ground voltage: <2mV RMS
- USB-A / USB-B / Peripherals connectors
- RJ12 connector for Robot
MSE-A
- Weight: 1.2 Kg (2.6 lb)
- Dimensions: 145 x 55 x 225 mm
- Vacuum: 75% / 570 mmHg / 22.4 inHg
- Flow rate: 9 SLPM
- P-005 Pedal connection
- Maintenance must not be carried out by children unless supervised.
Complies with CE standards
ESD protected housing “skin effect”
32
33
w w w.jbctools.com
Índice
Composición
Los siguientes artículos deberían estar incluidos:
Composición ....................................................35
JT Estación de Aire Caliente
Características ................................................39
Soporte ajustable ..........................................40
Extractor de boquillas ................................. 41
Protectores y extractores ............................42
T260 Lápiz posicionador .............................43
Funcionamiento y Control del proceso.....44
JT-TA Reemplazar elemento calefactor....47
JT-TA Cambiar el conjunto calefactor........47
DDE Unidad de Control y MSE módulo
Características ...............................................48
Soportes ..........................................................50
Limpiador de Puntas ................................... 51
T245 Cambiar Cartuchos ............................52
DR560 Cambiar Puntas ...............................53
DR560 Cambiar elemento calefactor ......54
DR560 Limpiar depósito de estaño .........55
DR560 Mantenimiento de las puntas ......56
Desoldar con la DDE y el MSE ..................56
MSE Puesta en marcha ...............................57
MSE Cambiar los filtros ...............................57
Funcionamiento .............................................58
Pantalla de trabajo ....................................... 59
Análisis del proceso ......................................60
Red de Soldadura .........................................61
Trabajar con Robots .....................................62
Actualizar el Sotware de la estación ........62
JTE Control Unit
Unidad de Control JTE .. 1 ud.
Ref. JTE-1D (120V)
JTE-2D (230V)
JTE-9D (100V)
DDE Control Unit
Unidad de Control DDE ... 1 ud.
Ref. DDE-1B (120V)
DDE-2B (230V)
DDE-9B (100V)
Electric Desoldering Module
Módulo desoldador
eléctrico ....................... 1 unidad
Ref. MSE-A
Stand
Soporte ....................... 1 unidad
Ref. JT-SD
Stand
Soporte ............... 1 unidad
Ref. AD-SD
Stand
Soporte .............. 1 unidad
Ref. DR-SD
Heater hose set
Conjunto calefactor ........ 1 ud.
Ref. JT-T1A (100V / 120V)
JT-T2A (230V)
General Purpose Handle
Mango para aplicaciones
generales ............ 1 unidad
Ref. T245-A
Desoldering Iron
Desoldador .................. 1 unidad
Ref. DR560-A
Mantenimiento ................................................63
Seguridad .........................................................64
Especificaciones ........................................... 65
Despiece ........................................................... 66
34
35
w w w.jbctools.com
Conjunto de accesorios JT
Ref. 0012332
Extractor stand*
Soporte de extractores .... 1ud.
Ref. 0008752
Tip Cleaner
Limpiador de puntas ....... 1 ud.
Ref. CL9885
Extractors*
Extractores
Ref. E2184
E2064
E2052
Protectors*
Protectores
Ref. P2220
P2230
P2235
P4000
P4010
Suction Cups*
Ventosas
Ref. 0930110
Ø 10 - 0934050 (x3)
Ø 4.7 - 0934070 (x1)
Tripod* · Tripode
Ref. T2050 (Ø 39mm)
T2250 (Ø 85mm)
Accessorios del DR560
Ref. 0010211
Tip cleaning set
Juego de limpieza de puntas ............... 1 unidad
Ref. 0965970
Suction Tube*
Tubo de succión
Ref. 0932330
Tips
Puntas ................. 3 unidades
Ref. C560005 (x1)
Ref. C560013 (x1)
Ref. C560004 (x1)
Tin deposit
Depósito de estaño .........1 ud.
Ref. 0812620
Spanner
Llave ........................... 1 unidad
Ref. 0780550
Filter Box
Caja de filtros ....... 1 unidad
Ref. 0780840
Internal gasket
Casquillo junta
interior ................... 2 unidades
Ref. 0812360
Metal tin diposit
Depósito de metal
para estaño ............... 1 unidad
Ref. 0812630
Cotton Filter
Filtros de algodón ... 1 unidad
Ref. 0781046
Filter Box
Caja de filtros ............ 1 unidad
Ref. 0005966
Suction Filter
Filtro de aspiración ... 1 unidad
Ref. 0821830
Contiene 10 filtros
Contiene 50 filtros
Nozzles
Boquillas
Ref. JN2015 (x1)
JN2012 (x1)
JN2020 (x1)
Contiene 10 filtros
Cartridges
Cartuchos ............... 2 unidades
Ref. C245903 (x1)
Ref. C245906 (x1)
Sponge
Esponja ....................... 1 unidad
Ref. S0354
Long Tip Cleaning set
Juego de limpieza de puntas largo ....... 1 ud.
Ref. 0965760
Metal Brush
Cepillo metálico ......... 1 unidad
Ref. CL6217
* Estos accesorios no se suministran con las estaciones JT-2QC / JT-1QC / JT-9QC.
36
37
w w w.jbctools.com
Pick & Place
Lápiz posicionador ... 1 unidad
Ref. T260-A
Bent Needles Set
Conjunto de
agujas dobladas......... 1 unidad
Ref. 0861660
Straight Needles Set
Conjunto de
agujas rectas .............. 1 unidad
Ref. 0901546
JT Características
USB-B connector
Actualice el software
de la estación en
www.jbctools.com
Suction Cup Set
Conjunto de ventosas .... 1 ud.
Ref. 0940163
Cleaning stick
Bastoncillo de limpieza .. 1 ud.
Ref. 0786640
Activación de
la bomba de
succión
Elemento
calefactor
Stand Cable
Cable del soporte ......... 2 uds.
Ref. 0011283
Module Cable
Cable del módulo .... 1 unidad
Ref. 0014874
Union Flanges
Bridas de unión ......... 1 unidad
Ref. 0011356
Contiene 2 bridas
Cables de red
Para DDE ................... 1 unidad
Ref. 0013671 (100/120V)
0010569 (230V)
Para JTE ..................... 1 unidad
Ref. 0009417 (100V/120V)
0009401 (230V)
Manual ....................... 1 unidad
Ref. 0017357
w w w.jbctools.com
Heater Hose set
Conjunto calefactor
Ref. JT-T1A (100V - 120V)
JT-T2A (230V)
Suction Tube
Tubo de succión
Ref. 0932330
Para trípodes y
extractores
Otra herramienta conectable:
Precision Heater hose set
Conjunto calefactor de precisión
Ref: TE-TB
Interruptor para
aire caliente
(ON / OFF)
Soporte
Ref. JT-SD
Pedal
Ref. P-005
Con el pedal pulsado se
emite aire caliente.
Entrada de red
Premium
Complete Rework Station
with Electric Pump
Ref. RMSE-C
38
Fusible
Conexión
equipotencial
39
w w w.jbctools.com
Soporte ajustable
Extractor de boquillas
El elemento ajustable del soporte se adapta a su posición de trabajo.
Changing nozzles quickly and safely.
2
1
Apague la
herramienta
y maneje con
cuidado.
El elemento
calefactor y la
boquilla todavía
están calientes.
Modos de operación
1. Desde el menú principal, seleccione el modo de activación de la herramienta en función de la
tarea a desarrollar.
Soporte + Autostart OFF
Soporte + Autostart ON
Pedal*
Pulse
Pulse el interruptor para emitir
aire caliente.
No
pulse
La herramienta se activa
automáticamente cuando se
levanta del soporte.
Pise
Use el pedal para el control
del calefactor.
*El pedal P-005 no se incluye
en esta estación.
Consulte nuestra web.
2. La herramienta deja de emitir aire caliente cuando se deja en el soporte.
Boquillas compatibles
El JT-TA funciona con las boquillas JT. Encuentre el modelo que mejor se ajuste a sus necesidades de
trabajo en www.jbctools.com
Recta
Ø mm
Plana
Doblada
Ø mm
A x B mm
Para una mejor sujeción de la boquilla:
1. Empuje la lengüeta hacia dentro con la ayuda
de un destornillador o unos alicates planos.
40
Ref.
Forma
Medida
JN2020
Recta
Ø 8mm
JN8417
Recta
Ø 10mm
JN2015
Doblada
Ø 4mm
JN2012
Doblada
Ø 6mm
JN6633
Doblada
Ø 8mm
JN7637
Plana
10 x 2mm
JN7638
Plana
20 x 2mm
JN7639
Plana
30 x 2mm
2. Inserte la boquilla en el conjunto calefactor.
41
w w w.jbctools.com
Protectores y extractores
T260 Lápiz posicionador
Para componentes pequeños (fig. 1 y 2)
Para componentes grandes (fig. 3 y 4)
Recomendamos usar protector + trípode
Recomendamos usar extractores
1
2
3
Esta herramienta permite colocar y retirar SMDs fácilmente gracias al sistema de succión de la unidad.
4
Pick & Place
Lápiz posicionador
Ref. T260-A
Protectores
* Ref. AxB (mm)
Apriete para
iniciar o detener
la succión
Extractores
* Ref. AxB (mm)
* Ref. AxB (mm)
P3353 4,3 x 3
48 P2230 15 x 15
52 E2052 20 X 20
P3786 5,2 x 5,2
60 P4010 17 x 17
64 E2064 20 X 26
P3352 5,2 x 7,5
P4005 18 x 29
80 E2184 24 X 24
P3355 5,2 x 9,5
P4030 18,5 x 18,5
E2068 27 X 27
P3356 6,2 x 4,2
P1068 18,5 x 24
E4020 28,5 X 28,5
P3785 7,2 x 7,2
P2685 28,5 x 28,5
E4015 31,5 X 31,5
P3784 8,2 x 8,2
P4085 31,5 x 31,5
E2084 33 X 33
P4035 9 x 13
P2672 33 x 46
E2100 38 X 38
P4040 9,5 x 19
P4002 50 x 50
P4080 9,5 x 21
P3357 52,5 x 14
32 P2220 10 x 10
P4045 10,5 x 21
P4090 11 x 16
24 P2235 12 x 17
* Ref. AxB (mm)
E2124 45 X 45
Inserte la aguja en la
ventosa apropiada
para una succión
correcta.
Funcionamiento
* Ref. øC (mm)
T2050 39
T2250 85
44 P4000 12,5 x 12,5
P3354 13,2 x 13,2
P4025 13,5 x 21,5
Evite que la aguja
sobresalga de la parte
inferior de la ventosa.
Tripodes
P1249 12 x 23
* Referencia del soporte de extractores
Elija la ventosa que mejor se adapte al componente (Temp. máxima de trabajo: 250ºC / 482ºF):
Extractor manual
1. Succionar
2. Soltar
Una vez activado el
botón de succión,
cubra el agujero del
lápiz con el dedo
hasta y recoja el
componente.
Levante el dedo del
agujero para soltar
el componente en el
sitio adecuado.
* Ref. øD (mm)
E2190 7
øD
42
43
w w w.jbctools.com
Funcionamiento de la JT
1. Colocar
Modo programa
2. Calentar
3. Soltar
ºC
Gráfico del programa
seleccionado
Disminuir número de
programa
Posicione la ventosa y
apriete el botón de succión.
Proyecte aire caliente con el
conjunto calefactor.
El componente se levantará
automáticamente cuando el
estaño se derrita.
Modo manual
T e m p ºC
Temperatura actual
Temperatura seleccionada
45 seconds
Air %
380
Air
100%
Time 125s.
Temperatura actual
Caudal seleccionado
Tiempo restante
Aumentar número de
programa
Opciones de Programa
400 85
Puede borrar el último punto del programa seleccionando “-----” en el parámetro Tiempo.
Tenga en cuenta que el rango de temperatura permitido por la estación es 150- 450°C, por lo que
no es posible crear rampas de temperatura entre la temperatura ambiente y los 150°C.
400ºC Select
Power 70%
% potencia
Confirme la selección
Para acceder al Menú (apriete 2 segundos)
Puede intercambiar los modos (manual / programa) apretando las teclas “aumentar” o “disminuir”
simultáneamente durante 2 segundos (sólo si el modo programa está activo).
44
Programa seleccionado
T e m p ºC
Edit Program
Esta opción le permite crear o editar un programa. Seleccione un número de programa a editar y
modifique los puntos en función de sus necesidades de trabajo. Cada programa se compone de 9
puntos y cada punto consiste en 3 parámetros:
1. Tiempo (segundos)
2. Temperatura (°C / °F)
3. Caudal de Aire (%)
Control del proceso
Time to stop
Program 8
La estación puede almacenar hasta 25 programas de temperatura. Los primeros 3 programas
que muestra la estación han sido editados por JBC a modo de ejemplo.
Copy Program
Esta opción le permite copiar un programa. Seleccione la opción “program source” e indique el programa que quiere copiar. A continuación seleccione “program destination” e indique el programa donde será copiado. En el momento de salir (Exit) podrá salvar los cambios.
Delete Program
Esta opción le permite borrar un programa previamente seleccionado.
45
w w w.jbctools.com
Pantallas de Menú
JT-TA Reemplazar el elemento calefactor
PIN original: 0105
Asegúrese que el elemento calefactor está frío y la unidad de control desconectada de la red.
Main menu
1
2
3
4
Reset settings
Station Settings
Program Settings
Counters
5
Program version
1. Afloje el tornillo.
2. Tire del elemento calefactor y sáquelo del mango.
3. Conecte el nuevo elemento calefactor hasta que encaje lo más adentro posible.
4. Atornille de nuevo.
Exit
Settings
Program Settings
1
2
3
4
Temp unit
Celsius
Maximum temp 4500C
Minimum temp
T OFF*
Fix temp
4000C
5
6
7
8
9
10
11
12
Temp Adjust
Max air
Min air
Fix air
Time to stop
Beep
Pop up
Change PIN
1
2
3
4
00C
100%
10%
40%
120 sec
ON
ON
ºC
Programs
Edit program
Copy program
Delete program
Edit Program
Select
Program
8
Heating Element
Elemento calefactor
Ref. 0014107 (230V)
0014105 (100V / 120V)
JT Handle
Manguera JT-A
Ref. JT-A
Heating Hose Set
Conjunto calefactor
Ref. JT-T1A (100V / 120V)
JT-T2A (230V)
JT-TA Cambiar el conjunto calefactor
Back
ºC
* Seleccionando “T OFF” en la
Mínima temperatura permite la
emisión de aire ambiente.
Edit Program 8
Step
4
Time
20
Temp 450
Air
100
Exit
1. Apague la herramienta.
2. Desenrosque la tuerca de conexión con la ayuda de
una llave inglesa.
3. Encaje el extremo del nuevo conjunto calefactor en
la unidad de control.
4. Siga los mismos pasos al revés.
Counters
1
2
3
Station ON hours
Works hours
Works cycles
0
0
0
Back
46
47
w w w.jbctools.com
Características DDE y MSE
Trabaje simultáneamente con 2 herramientas y enlace cada puerto con 1 módulo + 1 pedal (Peripherals).
Pantalla color TFT de 2,8”
Conector USB-A
Stand Cable
Cable del soporte
Ref. 0011283
Conexión equipotencial
Conector USB-B
Conector RJ12 para Robot
Toma de correinte
Cartridge
Cartucho
Ref. C245903
Ref. C245906
General Purpose
Handle
Mango para
aplicaciones generales
Ref. T245-A
Stand
Soporte
Ref. AD-SD
48
Tip
Punta
Ref. C560004
Ref. C560005
Ref. C560013
Incline la pantalla
para una mejor
lectura
Module Cable
Cable del módulo
Ref. 0014874
Electric Desoldering Module
Módulo desoldador eléctrico
Ref. MSE-A
Desoldering Iron
Desoldador
Ref. DR560-A
Stand
Soporte
Ref. DR-SD
A otro
periférico
Al Pedal
Ref. P-005
Suction Filter
Filtro de succión
Ref. 0821830
49
w w w.jbctools.com
Soportes ajustables
Limpiador de Puntas
Mejore la transferencia térmica de la punta limpiándola después de cada soldadura.
Recogecable
Mantiene el área de trabajo ordenada sin cable
Brass wool
Lana de latón
Ref. CL6210
Método de limpieza
muy efectivo. Deja una
fina capa de soldadura
en la punta para
prevenir la oxidación
entre la limpieza y la
rehumectación.
Cambio rápido
de cartuchos
Cambie cartuchos
sin interrumpir
su trabajo
Cambio rápido
de puntas
El sistema de
sujeción de puntas
facilita el cambio.
Stand
Soporte
Ref. AD-SD
Sponge
Esponja
Ref. S0354
El método de limpieza
más eficaz y menos
dañino. Mantenga la
esponja húmeda con agua
destilada, así evitará el
desgaste de la punta.
Base
antideslizante
No es necesario sujetar
la base.
Protección
anti-salpicaduras
Previene las
salpicaduras de
partículas de soldadura.
Limpiador
Ref. CL0236
Receptáculo resistente a la temperatura para eliminar
el exceso de soldadura golpeteando y limpiando.
Para esponja:
Golpeteo:
Para cepillos:
Stand
Soporte
Ref. DR-SD
Limpieza:
Mantenimiento
Ranuras para
Golpe suave
para retirar restos retirar partículas
adheridas.
de soldadura.
Se puede quitar
fácilmente para
su limpieza.
Opcional
Soporte de
herramienta
ajustable
Se adapta a
su posición
de trabajo.
50
Recogecable
ajustable
Inox wool
Lana inoxidable
Ref. CL6205
Brushes
Cepillos de metal
Ref. CL6220
Tip-tinner
Reestañador de puntas
Ref. TT-A
Sand · Arena
Ref. CL6211
51
w w w.jbctools.com
Cambiar cartuchos del T245
Cambiar puntas del DR560
Ahorre tiempo cambiando los cartuchos de forma rápida y segura sin apagar la estación.
Esta operación debe realizarse con la punta caliente (por encima de los 250°C) para que el estaño
de su interior se mantenga fundido.
1. Retirar
2. Insertar
3. Fijar
250ºC mínimo
1. Retirar
C
D
B
Desenrosque la punta utilizando la llave
suministrada.
A
2. Insertar
Coloque la punta nueva y enrósquela
con la llave para asegurarse que queda
hermético.
Coloque el soldador en el
extractor y tire para retirar
el cartucho.
Coloque el mango soldador
en la parte superior del
nuevo cartucho y presione
ligeramente.
Fije el cartucho* utilizando
los agujeros:
A. Para los C210 rectos.
B. Para los C210 curvados.
C. Para los C245 curvados.
D. Para los C245 rectos.
*Importante
Es necesario insertar el cartucho hasta la marca para una conexión correcta.
Puntas compatibles
El DR560 funciona con puntas C560.
Encuentre el modelo que mejor se adapte a sus necesidades de desoldadura en www.jbctools.com
Algunas de las puntas
C560 en tamaño real
(mm):
Aø
Bø
C560-001
ØA=1,4 ØB=0,6 Ømax. pin=0,4
C560-002
ØA=1,8 ØB=0,8 Ømax. pin=0,6
Marca
C560-001
C560-002
Cartuchos compatibles
El mango para soldador T245 funciona con cartuchos C245. Encuentre el modelo que mejor se
ø 3,5
ø 1 necesidades de soldadura en www.jbctools.com
adapte a sus
ø 1,5
C560-014
ØA=2,5 ØB=0,8 Ømax. pin=0,6
C560-003
C560-003
C560-014
C560-004
A
Redondo
52
Cincel
Redondo
curvado
Bisel
A
B
ØA=3,2 ØB=1,3 Ømax. pin=1,1
C560-004
ØA=2,7 ØB=1 Ømax. pin=0,8
C560-009
ØA=5 ØB=1,3 Ømax. pin=1,1
C560-009
Modelos
especiales
53
w w w.jbctools.com
DR560 Cambiar el elemento calefactor
DR560 Limpieza del depósito de estaño
Para realizar esta operación apague la estación o desconecte la herramienta.
1. Retirar la tapa
2. Limpiar
1. Desenroscar
Desenrosque la tapa del
depósito.
Compruebe la
junta interna
2
2. Retirar
Afloje el tornillo y retire el
elemento calefactor.
1
Retire el espiral para limpiar el interior del
depósito con la baqueta suministrada.
3. Colocar
Coloque el nuevo elemento
calefactor hasta la marca* y
siga los mismos pasos a la
inversa.
Compruebe
el filtro
3
Tapa
*Importante
Para una conexión apropiada es necesario insertar el cartucho alineándolo con la marca
.
La tapa se debe retirar con el desoldador en
posición vertical.
El filtro y la junta interna deben supervisarse
para reemplazarlos si fuera necesario, ya sea
por exceso de suciedad o por algún daño.
3. Insertar el depósito
El depósito se debe insertar con el espiral ya
colocado entre las dos marcas.
Concluya el proceso cerrando el depósito
con la tapa.
54
Marcas
55
w w w.jbctools.com
Puesta en marcha de la bomba MSE
Mantenimiento de puntas del DR560
Tras conectar el módulo desoldador eléctrico (MSE-A), entre en el menú de
Peripherals y seleccione el puerto con el que desee enlazar el módulo.
El conducto de entrada se debe limpiar periódicamente con la baqueta más grande posible.
17:14
Peripherals
1. Seleccione el módulo del listado de
conexiones periféricas. Recuerde que su
primera conexión se indica como “a”, la
segunda como “b”, etc. (MSE_a, MSE_b,...)
Peripherals
Pedal
Module
Module
MSE_a
Port 2-DR
None
None
None
Importante
NO pulse el botón de la bomba de succión mientras estaña la punta, ya que los humos producidos por el flujo bloquearían rápidamente los conductos y el filtro de aire.
2. Pulse Menu o Back para guardar los
cambios. Una vez configurado podrá
modificar cambios desde el menú Peripherals.
Proceso de desoldadura
Cambiar los filtros de la bomba MSE
La punta elegida debe tener un diámetro más grande que el pad para conseguir la máxima aspiración
posible y el mejor rendimiento térmico.
- Limpie la carcasa con un paño húmedo. Asegúrese que utiliza un paño suave para el frontal.
- Revise periódicamente los cables y tubos.
- Mantenga los filtros limpios para garantizar una correcta aspiración y reemplácelos si fuera necesario.
1. Colocar
2. Rotar
3. Aspirar
Suction filter
Filtro de aspiración
Ref. 0821830
Coloque la punta en el
terminal del through-hole
tal y como se muestra.
Cuando la soldadura se liqüe,
gire la punta con suavidad
para que el terminal del
componente se suelte.
Pulse el botón de la bomba
de succión hasta retirar
por completo los restos de
soldadura.
Tras pulsar el botón del desoldador hay un ligero retraso hasta que la bomba de succión se
detiene. Esto asegura que el conducto de succión está completamente vacío.
Si se quedaran restos de soldadura en algun terminal después de desoldarlo, vuelva a soldarlo
con estaño nuevo y repita el proceso de desoldadura.
56
Cotton filters
Filtros de algodón
Ref. 0781046
Anillo
Ref. 0007717
Tapa de filtros
Ref. 0004710
Filtros
Ref. 0005966
57
w w w.jbctools.com
Funcionamiento
Pantalla de trabajo
El exclusivo sistema calefactor de JBC
La DDE-B presenta una interfaz de usuario intuitiva y ofrece un rápido acceso a los parámetros.
Nuestra tecnología revolucionaria es capaz de recuperar la temperatura de la punta de forma
extremadamente rápida. Esto significa que el usuario puede trabajar a una temperatura más baja
y mejorar la calidad de la soldadura. Esta temperatura se reduce aún más gracias a los modos de
Sleep e Hibernation que incrementan hasta 5 veces la vida de las puntas.
1. Trabajo
2. Sleep
Barra de
estado
3. Hibernación
17:14
Herramienta
en uso
T245
Períodos
largos en el
soporte
Al levantar la herramienta
del soporte, la punta se
calienta hasta la temperatura
seleccionada.
Si la herramienta permenece
en el soporte, la temperatura
se reduce a la temperatura
predefinida.
17:14
350
Tras largos períodos de
inactividad (predefinido a
30min), se corta el suministro
de energía y la punta se enfría
hasta temperatura ambiente.
17:14
T245
Power
45%
Se muestra si
los niveles de
temperatura
están activos
250
Port
2
Notificaciones (Barra de estado)
Pulse INFO para la descripción de parámetros.
Hibernation
Unidad de memoria USB conectada.
Actual Temp. 25ºC
Tool in the stand
Delay to hibernation: 29:30
380
Cambio de
puerto
Actual Temp. 180ºC
Port
2
350
Ayuda de la
estación
Opciones de Menú
T245
Sleep
Selected 350ºC
Power
45%
Temp. Levels
17:14
T245
ºC
350
Indicador de
potencia
ºC
Port
2
Estación controlada por un PC.
Port
2
Estación controlada por un robot.
Menú Tools:
Menú Tools:
Menú Tools:
· Configure límites de temperatura.
· Seleccione niveles de temperatura.
· Configure la temperatura de Sleep
· Configure el tiempo de retraso de Sleep
(de 0 a 9 min o ninguno)
· Configure el retraso de
Hibernación
(de 0 a 60 min o ninguno)
58
Station
Tools
Counters
Actualización del software de la estación.
Pulse INFO para iniciar el proceso.
Aviso.
Pulse INFO para la descripción del fallo.
Peripherals
Graphics
Reset
Error. Pulse INFO para la descripción del
fallo, el tipo de error y cómo proceder.
59
w w w.jbctools.com
Red de soldadura
Análisis del proceso
Pulsando sobre Graphics en el menú principal, se muestran las respuestas de
temperatura y potencia en tiempo real de cada puerto. Esto le ayudará a decidir
cuál es la punta más adecuada para obtener la mejor calidad en sus soldaduras.
Graphics
1. Descargue el software JBC Manager y el manual de usuario de www.jbctools.com/manager.html
2. Conecte las estaciones a través del conector USB-B y el PC las detectará automáticamente.
3. La notificación
se mostrará en la estación.
Funciones:
- Configure todos los parámetros de la estación desde su PC.
- Organice grupos de estaciones y configure todos sus parámetros al mismo tiempo.
- Guarde configuraciones específicas para usos posteriores.
- Analice gráficos del proceso de soldadura de las estaciones desde su PC y expórtelos.
17:14
450
400
Potencia (%)
Gestione y monitorice tantas estaciones como soporte su PC.
350
300
250
200
Temperatura
150
100
JBC
Manager
software
50
Power
Temp
Port 1 - T245
Vea el gráfico
del otro puerto
USB Hub
Exporte gráficos
Inserte una unidad de memoria USB para
guardar su proceso de trabajo en formato csv.
cualquier
estación
JBC
60
61
w w w.jbctools.com
Trabajar con Robots
Mantenimiento
Gestione y monitorice la estación por medio de un sistema robotizado.
Antes de realizar tareas de mantenimiento o almacenar, desconecte el equipo y déjelo enfriar.
1. Conecte la herramienta a la estación utilizando el convertidor CHB-A (Ref: CHB-A).
2. Conecte su sistema robotizado al conector Robot de la estación (RJ12).
Si lo necesita, el adaptador DB9-RJ12 está disponible (Ref: 0013772).
3. Active la opción de robot en la estación y se mostrará la siguiente notificación:
4. Configure su sistema robotizado según el Protocolo de Comunicación para Robots,
que encontrará en www.jbctools.com/jbcsoftware-menu-115.html.
- Use un paño húmedo para limpiar la
pantalla del equipo, la carcasa y la herramienta. Puede utilizar alcohol solamente en las partes metálicas.
Convertidor
CHB-A
Ref. CHB-A
Robot
- Compruebe periódicamente que las partes
metálicas de la herramienta y del soporte
están limpias. Así la estación puede
detectar el estado de la herramienta y
activar los modos de Sleep o Hibernation.
Mantenga limpio
-Mantenga la punta limpia y estañada la
para evitar su oxidación. Las superfícies
sucias reducen la transferencia térmica a la
soldadura.
Unidad
de Control
Conexión
RS-232
- Revise periódicamente los tubos y cables.
- Cambie el fusible fundido de la siguiente manera:
Fusible
Actualice el software de la estación
1. Descargue el archivo de actualización de
www.jbctools.com/software.html
cuando esté disponible y guárdelo en una unidad de memoria USB (preferentemente una sin otros archivos).
JBC
Update File
2. Inserte la unidad de memoria USB.
La notificación
se muestra mientras se actualiza el software.
Portafusible
Portafusible
1. Tire del portafusible para retirar el fusible. Si lo precisa, utilice una pequeña palanca.
2. Sustituya el fusible y coloque de nuevo el portafusibles en su sitio.
- Cambie cualquier pieza defectuosa o dañada. Utilice solamente recambios originales de JBC.
- Cualquier reparación sólo se podrá realizar por un servicio técnico oficial JBC.
62
63
w w w.jbctools.com
Seguridad
Es necesario cumplir estas normas de seguridad para prevenir cualquier
choque eléctrico, heridas, fuego o explosiones.
- No utilice el equipo para otros fines que no sea la soldadura o reparación. El uso incorrecto puede causar fuego.
- El cable de red debe enchufarse en bases homologadas. Asegúrese de que está conectado a tierra correctamente antes de su uso. Al retirarlo, tire del conector, no del cable.
- No trabaje con tensión.
- La herramienta debe permanecer en el soporte mientras no está en uso con el fin de activar el modo de Sleep o Hibernación. El cartucho y las partes metálicas de la herramienta o del soporte pueden estar calientes incluso cuando con la estación apagada. Manipule con cuidado, incluso cuando se ajusta la posición del soporte.
- No deje el aparato desatendido cuando está en funcionamiento.
- No cubra las rejillas de ventilación. El calor puede causar que los productos inflamables se enciendan.
- Utilice flux clasificado como “non residue”. Evite el contacto con la piel y ojos para que no se irriten.
- Tenga cuidado con el humo producido al trabajar.
- Mantenga su lugar de trabajo limpio y ordenado. Use gafas y guantes de protección adecuados. Así evitará cualquier daño.
- Tenga cuidado con los restos de estaño líquido. En contacto con la piel, puede causar quemaduras.
- Este aparato puede ser utilizado por personas a partir de 8 años y también por aquellas personas con movilidad reducida o capacidades físicas, sensoriales o mentales limitadas o con falta de experiencia y conocimientos siempre y cuando reciban supervisión o instrucciones relativas al uso del aparato de una manera segura y entiendan los riesgos que implica. Los niños no deben jugar con el aparato.
- Los niños no deberán realizar tareas de mantenimiento sin supervisión.
64
Especificaciones
Complete Rework station with Electric Pump
Estación completa de reparación con bomba eléctrica
RMSE-1C / RMSE-2C / RMSE-9C
- Peso total: 16.6 kg (36.6 lb)
- Temperatura de trabajo ambiente: 10-40ºC (50-104ºF)
JTE-1D 120V 50/60Hz. Fusible de entrada: 8A
JTE-2D 230V 50/60Hz. Fusible de entrada: 4A
JTE-9D 100V 50/60Hz. Fusible de entrada: 8A
- Peso: 5.7 kg (12.6 lb)
- Dimensiones: 148 x 184 x 140
- Potencia nominal: 700W
- Rango de temperatura: Temp. ambiente / 150-450°C (300-840ºF)
Modo frío: T Off. Utilizado para emitir aire en temperatura ambiente.
- Regulación del caudal de aire: 10-50 SLPM
- Vacío: 30% / 228 mmHg / 9 inHg
- Conexión USB estación-PC
- Conector para pedal P-005
DDE-1B 120V 50/60Hz. Fusible de entrada: 4A. Salida: 23.5V
DDE-2B 230V 50/60Hz. Fusible de entrada: 2A. Salida: 23.5V
DDE-9B 100V 50/60Hz. Fusible de entrada: 5A. Salida: 23.5V
- Peso: 4.3 Kg (9.3 lb)
- Dimensiones: 148 x 120 x 232 mm
- Potencia máxima de pico: 150W por herramienta
- Rango de temperatura: 90-450°C (190-840 ºF)
- Estabilidad de temperatura en reposo: ±1.5 ºC (±3 ºF)
- Resistencia punta a tierra: <2 ohms
- Tensión en punta: <2mV RMS
- Conectores USB-A / USB-B / Peripherals (periféricos)
- Conector RJ12 para Robot
MSE-A
- Peso: 0.9 Kg (1.9 lb)
- Dimensiones: 145 x 55 x 225 mm
- Vacío a 6 Bar: 75% / 570 mmHg / 22.4 inHg
- Caudal de aire: 9 SLPM
- Conector para pedal P-005
Cumple con las normativas CE
Seguridad ESD
65
w w w.jbctools.com
Exploded View · Despiece
66
67
Warranty
JBC’s 2 year warranty covers
this equipment against all
manufacturing defects, including
the replacement of defective
parts and labour.
Warranty does not cover product
wear due to use or mis-use.
In order for the warranty to
be valid, equipment must be
returned, postage paid, to the
dealer where it was purchased.
Garantía
Esta garantía de 2 años cubre
este equipo contra cualquier
defecto de fabricación,
incluyendo la sustitución de partes
defectuosas y mano de obra.
La garantía no cubre el desgaste
del producto por uso o mal uso.
Para que esta garantía sea válida,
el equipo debe ser devuelto, a
portes pagados, al distribuidor
donde se compró.
This product should not be thrown in the garbage.
In accordance with the European directive 2012/19/EU, electronic equipment at the end of their life
must be collected and returned to an authorized recycling facility.
0017357-1215
Este producto no debe desecharse en la basura.
De acuerdo a la directiva europea 2012/19/UE, los equipos electrónicos al final de su vida se
deberán recoger y trasladar a una planta de reciclaje autorizada.
www.jbctools.com
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF