Bosch D296, D297 Beam Smoke Detectors Installation Instructions
Below you will find brief information for Beam Smoke Detectors D296, Beam Smoke Detectors D297. The D296 (24 VDC) and D297 (12 VDC) Long-range Beam Smoke Detectors have a separate transmitter and receiver. Internal pointability provides coverage flexibility without brackets. Automatic signal synchronization and range adjustment reduce installation costs. Selectable sensitivity and alarm response time provide installation flexibility.
Advertisement
Advertisement
Long-range Beam Smoke Detectors
D296/D297
en Installation Instructions
Long-range Beam Smoke Detectors
Table of contents
8
9
6
7
4
5
1
2
3
Notices
System overview
Installation considerations
Use correct wire gauge and length
Provide a stable mounting surface
Plan for the effects of stratification in cold environments
Design for the expected fire load
Mounting
Quick start installation flowchart
Wiring
Setup
Troubleshooting
Receiver - Aim Mode (cover off)
Receiver - Normal Mode (cover on)
Maintenance and Testing
Field sensitivity measurements
Specifications
Table of Contents | en
3
10
6
4
4
22
14
17
26
24
Bosch Security Systems, Inc.
Installation Instructions 2014.01 | 06 | F.01U.068.899
4
en | Notices Long-range Beam Smoke Detectors
1
!
Notices
Before installing the module, become familiar with the Installation and Operation Guide for the control panel you are using.
Caution!
When power is removed and reapplied to the receiver, such as in a power outage and restoral or an alarm reset, an internal setup procedure is initiated and can last from 1 min to 2 min.
During this period, the detector is not able to initiate signals. Avoid connecting these detectors to circuits, such as those programmed for alarm verification, that remove and reapply power.
1.1
1.2
2
2.1
Regulatory
FCC compliance
This equipment was tested and complies with the limits for a Class B digital device, pursuant to Part 15 of the Federal Communications Commission (FCC) Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy. When this equipment is not installed and used according to the instructions, it might cause harmful interference to radio communications. There is no guarantee that interference will not occur in a particular installation.
If this equipment causes harmful interference to radio or television reception that can be determined by turning the equipment off and on, correct the interference by:
– Reorienting or relocating the receiving antenna.
– Increasing the separation between the equipment and the receiver.
– Connecting the equipment to an outlet on a circuit different from the circuit to which receiver is connected.
– Consulting the dealer or an experienced radio or TV technician for help.
Codes and standards
Install, test and maintain the module according to these instructions, NFPA codes, local codes, and the authority having jurisdiction (AHJ). Failure to follow these instructions can result in failure of a detector to initiate an alarm event. Bosch Security Systems, Inc. is not responsible for improperly installed, tested or maintained devices.
Trademarks
All hardware and software product names used in this document are likely to be registered trademarks and must be treated accordingly.
System overview
Description
The D296 (24 VDC) and D297 (12 VDC) Long‑range Beam Smoke Detectors have a separate transmitter and receiver. Internal pointability provides coverage flexibility without brackets.
Automatic signal synchronization and range adjustment reduce installation costs. Selectable sensitivity and alarm response time provide installation flexibility.
Available accessories:
2014.01 | 06 | F.01U.068.899
Installation Instructions Bosch Security Systems, Inc.
Long-range Beam Smoke Detectors
2.2
Notices | en
5
– A D306 Remote Indicator Plate, a D1005 Test Cable, and a set of four plastic sensitivity test filters are included with each detector.
– A D307 Remote Test and Indicator Plate (not supplied) is required for remote alarm testing.
– A D308 Test Kit (not supplied) is needed for field testing.
– A D309 Alignment Light is also available to aid in transmitter/receiver alignment.
Operation
Each transmitter sends an invisible infrared beam of a specific frequency and intensity. Each receiver detects and measures the beam’s intensity (see the following figure).
Figure 2.1: Infrared Transmission
1 Transmitter
2 Beam
3 Receiver
As smoke obscures the beam, the receiver senses a decrease in the signal strength and measures that decrease. The receiver compares the signal level with two preset thresholds: an alarm threshold that is set using the sensitivity switch and a trouble threshold that is preset at approximately 10%. If the signal falls below the alarm threshold for the programmed alarm period, the receiver signals an alarm (see the following figure).
Figure 2.2: Beam Obscuration
1 Transmitter
2 Beam
3 Obscuring matter
4 Receiver
If the signal falls below the trouble threshold for more than 20 sec (caused by an object blocking the beam for example), the receiver signals a trouble condition (see the following figure).
Bosch Security Systems, Inc.
Installation Instructions 2014.01 | 06 | F.01U.068.899
6
en | Notices Long-range Beam Smoke Detectors
Figure 2.3: Beam Blockage
1 Transmitter
2 Beam
3 Blocking object
4 Receiver
3
3.1
The receiver automatically compensates for the gradual signal loss because of dust and dirt buildup on the cover. After a signal loss of 50%, the receiver indicates a trouble. When the built‑up dust and dirt are cleaned or the blockage is removed, the detector automatically returns to its normal operation level.
The receiver indicates a trouble if the beam strength increases by more than 20% for longer than 20 sec. A trouble can be caused by an initial misalignment or the removal of a partial beam blockage during alignment. Perform a fine‑tune alignment.
For alignment details, see Setup, page 17.
Installation considerations
Correct smoke detector location and spacing is critical in a properly installed and operating fire alarm system. For best results, place and space the detectors according to the National
Fire Protection Association (NFPA) Standard 72, The National Fire Code.
In all installations, good engineering judgment must prevail.
– Do not use mirrors. Install detectors with a clear line-of-sight between the transmitter and receiver.
– Clear the beam path of moving objects.
– Avoid areas with normal smoke concentrations, such as kitchens and garages.
– Do not install detectors where the normal ambient temperatures are below -22°F (-30°C) or above +130°F (+54°C).
– Set sensitivity based on the distance between the transmitter and receiver. For
information on selecting and setting sensitivity, see Design for the expected fire load, page
8 and Sensitivity setting, page 11.
Avoid air movement sources
– Place the transmitters/receivers where the beam path does not pass near heating and cooling outlets. Do not mount where hot or cold air blows directly into the beam path.
Heating, ventilating, and air conditioning (HVAC) systems can blow smoke away from the beam path. Smoke must accumulate in the beam path to be detected.
– Do not mount heaters close to the beam path. Heat can distort the beam.
– Test for beam distortion by monitoring the signal voltage. After setup, the detector’s signal voltage must read between 3.8 VDC and 4.2 VDC. Monitor the voltage and turn on all heating and cooling devices in the area. The signal voltage must not fluctuate more than 0.20 VDC. If it does, relocate the detector to avoid these disturbances.
2014.01 | 06 | F.01U.068.899
Installation Instructions Bosch Security Systems, Inc.
Long-range Beam Smoke Detectors
3.2
Avoid bright light sources
Notices | en
7
Bright light can cause stray signals. Do not point the receiver toward any of the following sources.
Sunlight: Do not point the receiver directly at the rising or setting sun. If installing the receiver
where sunlight cannot be avoided, mount it slightly higher than the transmitter and aim it down toward the transmitter. This causes the receiver to look below the horizon.
Bright Lights: Do not mount the receiver where it looks at exposed bulbs of high-pressure
sodium, mercury vapor, and metal halide lights. For an illustration of areas in which to avoid exposed lights, see the following figure.
Figure 3.1: Avoiding Exposed Lights
1 Receiver
3.3
2 Do not place bright lights in this area.
Bare fluorescent lights can also create a problem, especially in long hallways where a series of lights are perpendicular to the beam. Incandescent lights are not a problem as long as they are not directly in the beam path.
Use correct wire gauge and length
Beam smoke detectors are often used to protect large areas, requiring long wire runs to power the detectors and signal alarm conditions. The voltage available at the end of long wire runs might not be sufficient to power the detector, especially when the system is running on backup battery power. Use the correct wire gauge when installing detectors.
For the proper number of transmitter and receiver pairs depending on wire size and length, see the following table.
Wire Length
500 ft (152 m)
1000 ft (304 m)
2500 ft (762 m)
5000 ft (1524 m)
Table 3.1: Wire Gauge and Length
14 AWG
(ISO 2.5 mm
2
)
20 pairs
10 pairs
4 pairs
2 pairs
Wire Size
16 AWG
(ISO 1.5 mm
2
)
13 pairs
6 pairs
3 pairs
1 pair
14 AWG
(ISO 0.75 mm
2
)
8 pairs
4 pairs
2 pairs
1 pair
3.4
Provide a stable mounting surface
Beam smoke detectors depend on the projected beam measurement to sense smoke. Trouble or alarm conditions can be caused by shifts in beam alignment when the transmitter or receiver moves.
Bosch Security Systems, Inc.
Installation Instructions 2014.01 | 06 | F.01U.068.899
8
en | Notices
3.5
3.6
Long-range Beam Smoke Detectors
Never mount a detector to a suspended support, such as a pipe or length of wood that is supported at only one end. This type of mounting can create a pendulum effect that greatly multiplies even very small movements at one end of the support. For example, a 2 in. (5.1 cm) movement translates into a beam misalignment of more than 20 ft at 350 ft (6 m at 107 m).
Support mounting surfaces at opposite corners to reduce the pendulum effect.
Always select surfaces that are not subject to building movement. The automatic compensation circuits eliminate most problems created by normal building expansions and contractions. In some unusual circumstances, the walls and support structure might be subject to more significant movement because of heavy equipment operation, such as cranes anchored to the top of the walls.
When you are uncertain about mounting surface stability, measure the detector’s signal voltage. This voltage must be between 3.8 VDC and 4.2 VDC. Beam misalignment can cause this voltage to increase or decrease. The detector indicates a trouble condition when the voltage increases to greater than ~4.8 VDC or decreases to less than ~2 VDC over a long period. A trouble condition also occurs when voltage decreases to ~0.4 VDC for more than
20 sec. For how to take a voltage reading, see Reference voltage adjustment, page 24.
If you expect the mounting surface to move, relocate the detector to a stable surface or add supports to the mounting surface to prevent movement.
Mounting the detector to a square or octagonal electrical mounting box of 4 in. (10 cm) can bow the mounting plate. Bowing can occur because the mounting box screw tabs are below flush with the top edges of the mounting box. Over tightening the mounting screws bows the mounting plate inward at the bottom, causing the optics to aim low.
Irregularities in the flatness of the mounting box edge surfaces or at the screw tabs worsens this condition. Only use mounting boxes with flat, regular surfaces and properly formed screw tabs. Tightening the mounting screws to secure the mounting plate to 2 in. (5 cm) or 2 lb
(0.9 k) torque minimizes misalignment caused by mounting plate bowing.
Plan for the effects of stratification in cold environments
Air stratification might prevent smoke from reaching detectors mounted close to the ceiling.
Stratification occurs when smoke, rising because it is warmer than the surrounding air, reaches a level where it is the same temperature as the surrounding air and does not rise to the ceiling. In extremely cold environments such as unheated warehouses, smoke cools very quickly and is less likely to rise to the ceiling. Add more detectors at lower mounting heights to compensate.
Design for the expected fire load
When designing a fire alarm system, set detector sensitivity to respond to the proper smoke obscuration and to reduce the chance of a false activation within the application. The total obscuration of the infrared beam depends on the density of the smoke and width of the smoke cloud along the beam path as illustrated in the following figure.
2014.01 | 06 | F.01U.068.899
Installation Instructions Bosch Security Systems, Inc.
Long-range Beam Smoke Detectors Notices | en
9
Figure 3.2: Smoke Densty and Obscuration Graph
1 Smoke density
2 UL minimum sensitivity
3 UL maximum sensitiivity
4 Distance between transmitter and receiver
Determine the total obscuration needed for an alarm and select the sensitivity setting needed according to the following table.
Total Obscuration at Alarm
20%
30%
40%
50%
60%
70%
Sensitivity Switch Setting
2
0 or 3
4
5
1 or 6
7
Bosch Security Systems, Inc.
Installation Instructions 2014.01 | 06 | F.01U.068.899
10
en | Notices
4
Long-range Beam Smoke Detectors
The D296 and D297 can be set for quick response (5 sec) or normal response (30 sec). Some burning materials release hazardous gases along with the smoke and should be set for a shorter response times to minimize exposure to the dangerous vapors. Denser smokes, if allowed to collect for too long (obscuration time set too long), can produce near total obscuration of the detector resulting in a trouble signal before an alarm is generated. For example, fires caused by the ignition of flammable petroleum-based liquids generally lead to a rapid buildup of heavy smoke. When this type of fire is probable, use sensitivity settings 0 or 1 for a 5-sec response time.
For instructions on setting the sensitivity, see Sensitivity setting, page 11.
Mounting
Notice!
Use this product in indoor, dry applications only.
1.
Install a 4‑in. square or octagonal electrical box (or equivalent) to a rigid surface that is not subject to movement or vibrations.
2.
Remove the screw on the receiver's access door. Then remove the cover’s four screws indicated in the following figure.
Figure 4.1: Access Door and Cover
1 Access door 2 Cover mounting screws (4)
3.
Remove the receiver back plate by unscrewing the single mounting screw from the top of the circuit board carrier plate and separating the two plates as indicated in the following figure.
2014.01 | 06 | F.01U.068.899
Installation Instructions Bosch Security Systems, Inc.
Long-range Beam Smoke Detectors Notices | en
11
Figure 4.2: Removing the Back Plate
1 Remove screw to expose back plate
2 Mounting slots (4)
3 Back Plate
4 Wiring entrance
5 Do not remove
!
Warning!
Remove power to all wiring before proceeding.
4.1
4.
Route the wiring from the electrical box through the wire entrance. If you are going to connect a D306 or D307, route that wiring also.
5.
Mount the back plate to the electrical box.
6.
Attach the circuit carrier plate to the back plate using a single mounting screw.
7.
Repeat Steps 1 through 6 to mount the transmitter.
Sensitivity setting
1.
Select the appropriate sensitivity setting based on the distance between the transmitter and receiver. For a list of distances including some settings that overlap, see the following table. Select a lower setting for a more sensitive detection or select a higher setting for better immunity to false alarms.
6
7
4
5
1
2
3
Switch Setting Sensitivity Alarm Response Beam Length
0 30% 5 sec 30 ft to 100 ft (9 m to 31 m)
60%
20%
30%
5 sec
30 sec
30 sec
100 ft to 350 ft (31 m to 107 m)
30 ft to 50 ft (9 m to 15 m)
45 ft to 75 ft (14 m to 23 m)
40%
50%
60%
70%
30 sec
30 sec
30 sec
30 sec
70 ft to 100 ft (21 m to 31 m)
90 ft to 140 ft (27 m to 43 m)
120 ft to 180 ft (37 m to 55 m)
160 ft to 350 ft (49 m to 107 m)
Bosch Security Systems, Inc.
Installation Instructions 2014.01 | 06 | F.01U.068.899
12
en | Notices Long-range Beam Smoke Detectors
Switch Setting Sensitivity Alarm Response Beam Length
8* Not used
9* Not used
* Do not use positions 8 and 9. They are not valid.
2.
Set the receiver’s sensitivity switch to your selected setting. The sensitivity switch is located to the right of the optical module. The indicator, or pointer marking, runs along the side of the switches' shaft as indicated in the following figure.
Figure 4.3: Sensitivity Switch
2014.01 | 06 | F.01U.068.899
Installation Instructions Bosch Security Systems, Inc.
Long-range Beam Smoke Detectors
4.2
Quick start installation flowchart
Notices | en
13
Figure 4.4: Installation Flowchart
Bosch Security Systems, Inc.
Installation Instructions 2014.01 | 06 | F.01U.068.899
14
en | Notices
5
5.1
!
Long-range Beam Smoke Detectors
Wiring
Warning!
Only apply power after all connections are made and inspected.
Notice!
Do not install on fire circuits programmed for alarm verification.
Notice!
Do not coil excess wiring inside the units.
Wiring a single detector
When wiring the transmitter and receiver terminals, see the following figure and table.
Figure 5.1: Wiring a single detector
1 Fire alarm control panel (FACP)
2 Receiver
Type
Transmitter terminals
Receiver terminals
2014.01 | 06 | F.01U.068.899
Terminal
1 and 2
1, 2, and 3
3 End-of-line (EOL) resistor
4 Transmitter
Description
Input power terminals. for operating voltages, see
Form C auxiliary relay contacts. On fire alarm, Terminals
1 and 2 open; Terminals 2 and 3 close (short).
Installation Instructions Bosch Security Systems, Inc.
Long-range Beam Smoke Detectors
5.2
Notices | en
15
Type Terminal Description
Receiver terminals
Receiver terminals
4 and 5
6 and 7
On fire alarm, normally open (NO) fire alarm contacts close (short).
On trouble, normally closed (NC) trouble contacts open.
Receiver terminals
8 and 9 Input power terminals. For operating voltages, see
Table 5.1: Transmitter and Receiver Terminals
Notice!
To reset after a fire alarm, interrupt power to the receiver for a minimum of 1 sec. If the fire panel does not allow you to reset, install a switch in series with Terminal 8.
Wiring a remote indicator
A D306 Remote Indicator Plate is shipped with the D296 as a standard accessory. The D306 has three LEDs to indicate the detector’s condition and status and test points for measuring the sensitivity voltage. Although the D306 is not required, the manufacturer recommends its installation to check the detector’s condition from ground level. If using D306 Remote
Indicator Plate, install the remote indicator connector to the receiver as indicated in the following figure.
Bosch Security Systems, Inc.
Installation Instructions 2014.01 | 06 | F.01U.068.899
16
en | Notices Long-range Beam Smoke Detectors
Figure 5.2: Connecting a D306 Remote Indicator Plate
1 D306 Remote Indicator Plate
Connector
2 D296/D297 Receiver
3 EOL resistor
5.3
4 FACP
5 D306 Remote Indicator Plate
6 Wiring: a=orange, b=blue, c=black, d=red, e=yellow, f=green, g=violet
You can wire the D306 a maximum of 500 ft (152 m) from the receiver.
A D307 Remote Test and Indicator Plate can be used in place of the D306 and should be connected if remote alarm testing is desired. To connect a D307, follow the instructions in the
D307 Installation Instructions.
Wiring multiple detectors
For smooth, flat ceilings, mount the detectors so there is spacing of no more than 60 ft
(18.3 m) between beam paths (with no more than half of this spacing between the beam path and side wall, the wall parallel to the beam path). Other spacings depend on ceiling height, air flow characteristics, and response requirements. The minimum spacing between alternated adjacent detectors is 1/10th the distance between the transmitter and receiver. For example, if the beam length is 300 ft (91 m), place the detectors a minimum of 30 ft (9.1 m) apart. For layout placement, see the following figure.
2014.01 | 06 | F.01U.068.899
Installation Instructions Bosch Security Systems, Inc.
Long-range Beam Smoke Detectors Notices | en
17
Figure 5.3: Transmitter and Receiver Placement
1 Receiver
2 FACP
3 Transmitter
4 EOL resistor
5 Minimum spacing = 1/10 x distance
6 Minimum spacing = 1/5 x distance
* maximum spacing between adjacent systems is 60 ft (16.3 m)
Notice!
When two or more adjacent detectors are installed in the same area, alternate the transmitter and receiver locations. If the transmitter and receiver are not alternated, ensure the spacing between the detectors is 1/5th the distance from the transmitter to the receiver.
6 Setup
Before performing a setup, ensure all connections are made and secure. Then, apply power to the transmitter and receiver.
1.
To allow the transmitter to power up while the cover is off, press the transmitter’s Aim
Mode button located above the green LED as indicated in the following figure.
Bosch Security Systems, Inc.
Installation Instructions 2014.01 | 06 | F.01U.068.899
18
en | Notices Long-range Beam Smoke Detectors
Figure 6.1: Transmitter Circuit Board Showing Aim Mode Button
1 Aim Mode button 2 Green LED
2.
Ensure the green LED flashes on and off. If this LED is off, check for power and proper polarity on Terminals 1 (–) and 2 (+). If the green LED is steadily lit, you have a faulty transmitter. To begin the process of obtaining a replacement, call the Bosch National
Repair Center at (800) 366-2283 or send an e-mail to [email protected].
3.
Check the three receiver LEDs indicated in the following figure. It is normal for all three
LEDs to be on at this time, with the green LED either flashing or steadily on. If all LEDs are off, check for power and proper polarity on Terminals 8 (–) and 9 (+).
Figure 6.2: Receiver LEDs
6.1
1 Alarm LED (red)
2 Trouble LED (yellow)
3 Normal LED (green)
4.
Depending on your application, an aid to alignment might be necessary. If so, mount an aiming light, D309 or equivalent, as close to the receiver as possible, preferably on top of the receiver.
5.
Point the aiming light at the transmitter using it as your aiming guide.
Preliminary alignment
Each optical module has two alignment mirrors, one on each side, for preliminary alignment as indicated in the following figure.
2014.01 | 06 | F.01U.068.899
Installation Instructions Bosch Security Systems, Inc.
Long-range Beam Smoke Detectors Notices | en
19
Figure 6.3: Optical Module
1 Front view
2 Vertical fine tune
3 Horizontal fine tune
4 Side view
5 Alignment mirrors (3)
6 Rear bore sights (2)
7 Front bore sight
1.
Look into either mirror from a side angle at a minimum of 2 ft (61 cm) from the module.
2.
Use the rear and front sights in the same way as you use sights when aiming a gun.
3.
Rotate the transmitter's optical module left or right until you see the aiming light image
(or receiver’s image, if aiming light is not used) in the mirror. The optical module points at objects seen in the mirror when the front bore sight is in the center of the rear bore sights as indicated in the following figure.
Figure 6.4: Alignment Mirror
1 Rear bore sights (2) 2 Front bore sight
4.
If the optical module is initially aimed too high or too low, adjust the Vertical Fine Tuning adjustment Allen screw (with the supplied Allen wrench) slightly up or down until you see the image.
Bosch Security Systems, Inc.
Installation Instructions 2014.01 | 06 | F.01U.068.899
20
en | Notices
6.2
Long-range Beam Smoke Detectors
5.
Use the Vertical Fine Tuning adjustment screw and the Horizontal Fine Tuning adjustment screw to fine tune the image to the center of the mirror (aligned with the front and rear bore sights).
6.
Replace and secure the transmitter's cover.
7.
Ensure the transmitter's green LED is flashing.
8.
Replace and secure the transmitter's access door.
9.
Align the receiver to the transmitter image following Steps 1 through 7.
10. Ensure the receiver's green LED is flashing, indicating the preliminary alignment is complete.
11. If the receiver’s green LED is not flashing, repeat Steps 1 through 9 for the receiver.
Fine-Tune alignment
1.
Connect the D1005 Test Cable (supplied) to Pins 1, 2, and 3 of P6. These pins are located to the right of the receiver’s terminal strip as indicated in the following figure.
Figure 6.5: D1005 Connection
1 Connector wires: a = white, b = red [+], c = black [-]
Notice!
If the Remote Indicator Plate connector is installed, temporarily disconnect it.
2.
Connect a 20,000 Ω/VDC VOM (or greater) to the D1005’s black (–) and red (+) leads.
Set the meter scale so you see the readings ranging from 0 VDC to 5 VDC.
3.
Check the three receiver LEDs on the receiver.
– If the receiver gets the beam, the green LED flashes and the red and yellow LEDs are steadily on.
– If the green LED is steadily on, the beam is not reaching the receiver. Realign according to
the procedure described in Preliminary alignment, page 18.
4.
Observe the meter readings. Adjust the receiver’s optical module using the horizontal and vertical fine‑tuning adjustment screws for a maximum meter reading.
Notice!
This is the most critical alignment process. For the most effective system operation, ensure you have peak voltage during the fine-tune alignment.
2014.01 | 06 | F.01U.068.899
Installation Instructions Bosch Security Systems, Inc.
Long-range Beam Smoke Detectors Notices | en
21
Notice!
When performing fine-tune alignment, keep your arms and hands away from the front of the receiver and out of the beam path.
– The maximum voltage peak reading varies, depending on the distance between the transmitter and receiver. The acceptable peak voltage range is from 0.50 V to 5.00 V. The voltage at the receiver is greater at shorter distances.
– Make a note of the alignment voltage. It might be helpful if you need to troubleshoot at another time.
Notice!
Peak the voltage to ensure a stable and trouble-free detector.
5.
After completing the fine-tune alignment, remove the test cable.
6.
Replace and secure the receiver’s cover.
7.
Check the status of the receiver’s green LED to ensure it is still flashing.
8.
With the meter still connected to the test cable, reinstall this cable to P6. Route the test cable through the opening in the cover (white lead towards center of the receiver).
9.
At this point, you can perform an Alarm Test. Connect the D1005’s white and black wires.
Reset the receiver by temporarily removing power.
10. Press the receiver’s Setup button, located below the P6 and test cable connection as indicated in the following figure.
Figure 6.6: Receiver Setup Button
1 LEDs 2 Setup button
Notice!
Only press the Setup button if the covers are on both the transmitter and receiver.
– A 1-min to 2-min automatic internal setup process begins. This setup ends in a reference voltage that is used to measure beam blockages.
– The red and yellow LEDs turn off and the green LED turns steadily on. After some voltage fluctuations, the meter sets to 5.0 VDC.
Notice!
During this time, do not block the beam or move the units.
Bosch Security Systems, Inc.
Installation Instructions 2014.01 | 06 | F.01U.068.899
22
en | Notices
7
7.1
7.2
Long-range Beam Smoke Detectors
11. At the end of the setup, the receiver’s green LED flashes and the voltage decreases to a range from 3.8 VDC to 4.2 VDC. Use this voltage as a reference when you compare later readings to determine the need for cleaning. If the voltage is not within this range, press the Setup button.
12. After setup, remove the test cable.
13. Reconnect the D306 or D307 connector if used.
14. Replace and secure the access door.
Troubleshooting
Transmitter
LED
Flashing
Off
Condition
Normal
Solution
1. There is no power at the transmitter.
2. The Aim Mode button not pressed.
3. The transmitter is faulty.
1. Restore power to Terminals 1 and 2.
2. Press the Aim Mode button.
3. Replace the transmitter.
Receiver - Aim Mode (cover off)
Red
LED
On
Yellow
LED
On
Green
LED
Terminals
4 and 5
Flashing Open
Terminals
6 and 7
Open
Condition Solution
On
On
On
On On Open
Flashing Flashing Open
Off Off Open
Open
Open
Open
The alignment is acceptable.
The beam is blocked or the receiver is misaligned.
Clear the beam path or realign the receiver.
The sensitivity setting is invalid.
Set the receiver to the proper setting.
There is no power.
Check for power at
Terminals 8 and
9.
2014.01 | 06 | F.01U.068.899
Installation Instructions Bosch Security Systems, Inc.
Long-range Beam Smoke Detectors
7.3
Receiver - Normal Mode (cover on)
Red
LED
Off
Off
Off
Off
Off
Off
Off
On
Yellow
LED
Off
Green
LED
On
Off
Off
Off
On
On
On
Off
On
On
Terminals
4 and 5
Open
Open
Flashing Open
Flashing Open
Open
Flashing Open
Flashing Open
Flashing Closed
Terminals
6 and 7
Closed
Open
Closed
Open
Open
Open
Open
Closed
Condition
Notices | en
23
Solution
The receiver is initializing. It stabilizes in 60 sec to
120 sec.
The receiver is initializing. The access door is missing or loose.
Replace the access door.
Normal
The access door is missing or loose.
Trouble. Beam is blocked or misaligned.
Trouble. If the reference voltage is less than ~2 VDC, dust on the lens reduced the signal strength or vibration misaligned the receiver.
Replace the access door.
Clear the beam path or realign the receiver.
Clean the transmitter and receiver covers.
If the reference voltage does not return to
3.8 VDC to
4.2 VDC, realign the receiver and press the Setup switch.
If the reference voltage is greater than ~4.2 VDC, the beam strength increased because an initial beam misaligned or a partial blockage was removed at setup.
Perform a finetune alignment of the receiver and use the
Setup button.
Alarm Determine the cause of the alarm and reset the receiver.
Bosch Security Systems, Inc.
Installation Instructions 2014.01 | 06 | F.01U.068.899
24
en | Notices Long-range Beam Smoke Detectors
8
8.1
8.2
Red
LED
On
Yellow
LED
Off
Green
LED
Terminals
4 and 5
Flashing Closed
Terminals
6 and 7
Open
Condition Solution
On On On Closed Open
Alarm. The access door is missing or loose.
Determine the cause of the alarm and reset the receiver.
Replace the access door.
Alarm and Trouble. An alarm occurred, then the beam was blocked.
Determine the cause of the alarm and reset the receiver.
Clear the beam path.
Maintenance and Testing
Fire alarm reset
Reset the receiver after a fire alarm by removing power from the receiver for at least 1 sec., then reapply power.
For additional information, see Power outage, page 24.
Reference voltage adjustment
Notice!
Clean covers are necessary for proper reference voltage readings. For cleaning procedures,
Check the detector’s reference voltage a minimum of once each year. Check the voltage more often if required by local regulations or AHJs.
To check the reference voltage, connect a VOM to the voltage monitor contacts on the D306 or D307 if used. If you do not have a D306 or D307 connected to the detector, remove the receiver access door and measure the reference voltage using the supplied test cable. For
cable connection, see Fine-Tune alignment, page 20.
If the voltage is less than 3.8 VDC or greater than 4.2 VDC, remove the access cover and press the setup button to initiate a reset of the reference voltage. The reset can take 1 min to 2 min.
8.3
Cleaning
Clean the outside of the covers a minimum of once each year. Use a common window cleaner and a soft, clean cloth. Under normal conditions, there is no trouble alarm if the beam is not continuously blocked for longer than 18 sec. After cleaning, recheck the reference voltage. If voltage is less than 3.8 VDC or greater than 4.2 VDC, reset the reference voltage using the
procedure in Reference voltage adjustment, page 24.
Power outage 8.4
When power is removed and reapplied to the receiver, such as in a power outage or alarm reset, the original reference voltage information is lost.
– If the cover is on during power‑up, the receiver automatically restarts the internal setup process for a new reference voltage when power is applied.
2014.01 | 06 | F.01U.068.899
Installation Instructions Bosch Security Systems, Inc.
Long-range Beam Smoke Detectors
8.5
– If the cover is off, reattach it and press the setup button.
Remote test
Notice!
A D307 is required for the remote alarm test.
8.6
Notices | en
25
Notice!
Clean covers are necessary for proper reference voltage readings. For cleaning procedures,
see Cleaning, page 24. For aiming procedures, see Preliminary alignment, page 18 and Fine-
With a D307 connected to the receiver, use the following procedure to perform a remote test.
1.
Insert the operating key and turn the switch to the TEST position for a minimum of 5 sec.
– The red LED lights steadily and the system sounds an alarm.
2.
Turn the switch to RESET for a minimum of 1 sec.
– The red LED turns off and the green LED lights steadily for approximately 60 sec to
120 sec.
– The receiver proceeds with its Setup Mode. When the setup is completed, the green LED begins flashing.
3.
Connect a standard volt-ohm meter (VOM) to the voltage monitor plugs. The voltage reading must range between 3.8 VDC and 4.2 VDC when clean and properly aimed.
Notice!
You can also use the voltage monitor to check the sensitivity level of the detector. As the signal level decreases because of dust or dirt buildup on the lenses or system misalignment, the voltage reading also decreases.
Field sensitivity measurements
Notice!
Testing these detectors activates a fire alarm. Inform all concerned personnel before performing a test.
The detectors automatically compensate for the effects of dust and dirt accumulation on their covers. They also compensate for component aging.
Notice!
NFPA 72 requires the detector sensitivity be measured in the field within one year after its initial installation and every alternate year thereafter.
Use the Sensitivity Test Kit supplied with the detector to check detector sensitivity only during installation. For field testing, order and use a D308 Test Kit.
Each filter decreases the detector’s signal by a specific amount. When you place a filter in front of the receiver’s optical module for a minimum of 30 sec (5 sec for position 0 or 1), you can determine the approximate sensitivity setting of the installed detector by its response as shown in the following table.
Bosch Security Systems, Inc.
Installation Instructions 2014.01 | 06 | F.01U.068.899
26
en | Notices
9
Long-range Beam Smoke Detectors
Sensitivity Setting
2
0 or 3
4
5
Must Not Alarm
0% (no filter)
0% (no filter)
20% (filter)
20% (filter)
1 or 6
7
Table 8.1: Sensitivity and Response
40% (filter)
40% (filter)
Specifications
Electrical
Alarm Current (Receiver)
Standby Current
Operating Voltage
Alarm contacts
Auxiliary alarm contacts
Trouble contacts
Must Alarm
40% filter
60% filter
60% filter
80% filter
80% filter
80% filter
D296: 70 mA maximum at 24 VDC
D297: 75 mA at 12 VDC
D296 Receiver: 45 mA at 24 VDC
D296 Transmitter: 20 mA at 24 VDC
D297 Receiver: 50 mA at 12 VDC
D297 Transmitter: 20 mA at 12 VDC
D296: 18.0 VDC to 32.0 VDC
D297: 10.2 VDC to 15.0 VDC
Normally Open (N/O) contacts rated 1 A, 60 VDC maximum for DC resistive loads; do not use with capacitive or inductive loads
Normally Open (N/O) contacts rated 1 A, 60 VDC maximum for DC resistive loads; do not use with capacitive or inductive loads
Normally Closed (N/C) contacts rated 1 A, 60 VDC maximum for DC resistive loads; do not use with capacitive or inductive loads
Environmental
Environment
Relative humidity
Temperature
(storage and operating)
Indoor, dry
0% to 95%, non‑condensing
-22°F to +130°F (-30°C to +54°C)
For UL Listed installations, the range is +32°F to +130°F (0°C to +54°C)
2014.01 | 06 | F.01U.068.899
Installation Instructions Bosch Security Systems, Inc.
Long-range Beam Smoke Detectors Notices | en
27
Mechanical
Dimensions
Mounting
Pointability
Sensitivity
System Signaling
Signal Delay
Spacing
(distance between systems)
Transmission range
Tamper
7 in. x 5.5 in. x 5.5 in. (17.8 cm x 14 cm x 14 cm) mount to 3.5 in. or 4-in. square or octagonal electrical boxes or European Beza boxes
Internally pointable optics for ±90° horizontal, and ±10° vertical adjustment
Field selectable for 20%, 30%, 40%, 50%, 60%, or 70% beam obscuration
Conventional four-wire system; do not use with systems incorporating an alarm verification feature
Fire: Selectable 30 sec or 5 sec
Trouble: 20 ± 2 sec
60 ft (18 m) maximum; spacing confirmed by Underwriters
Laboratories (UL) testing
30 ft (9 m) to 350 ft (107 m)
Receiver: Access door tamper switch in series with trouble contacts.
Transmitter: When the cover is removed, the cover tamper switch interrupts transmission
Bosch Security Systems, Inc.
Installation Instructions 2014.01 | 06 | F.01U.068.899
Bosch Security Systems, Inc.
130 Perinton Parkway
Fairport, NY 14450
USA
www.boschsecurity.com
© Bosch Security Systems, Inc., 2014
F.01U.068.899
Advertisement
Key features
- Internal pointability
- Automatic signal synchronization
- Range adjustment
- Selectable sensitivity
- Alarm response time
- Remote indicator plate
- Remote test and indicator plate
- Test cable
- Sensitivity Test filters