Carlo Gavazzi CTD1X1001AXXX Solid core Current transformer 100A/1A Data Sheet
Add to my manuals
2 Pages
advertisement
▼
Scroll to page 2
Accessories AC Current Transformer (max 23mm Ø cable) Type CTD-1X • Cable and bus-bar type current transformer • 0.5 class, currents from 50 to 300 A • Removable DIN-rail mounting holder • Removable panel fixing clips • 2 cable/bus-bar isolated fixing screws • Double screw terminals (up to 8-wire connections) • Sealable terminal block covers Product Description Ordering Key CTD-1X 100 5A XXX Cable/Bus-bar type current transformer with DIN-rail/busbar and panel mounting facility. Model Primary current Secondary current Option Rated primary currents from 50 A to 300 A. Optional fixing kit: CTD-kit Type Selection Primary current Secondary current Option From 50 to 300A (Refer to Range Table) 1A 5A XXX: XTX: none tropicalization Input Specifications Operating frequency Max. system voltage Rated insulation level Insulation class Short-time current rating Ith Idyn Extended current rating Security factor (FS) 48 to 62 Hz 0.72 kV 3 kV/1 min. @ 50 Hz E (max 75°C) Typical 100 In /1 s 2.5 Ith The short-time thermal current Ith is anyway limited by the cable/bus-bar size 120% ≤ 5 (Class: 0.5, 1 and 3) Special features Working temperature Storage temperature Approvals Connection Cable cross section area General Specifications Standards Housing Mounting Standard accessories Optional accessories According to EN61869-2 ABS, self-extinguishing: UL 94 V-0 DIN-rail bus-bar and panel mounting Two terminal block screws. Two sealable terminal block covers. Two panel mounting fixing clips. One DIN rail adapter. Extended fixing kit CTD-kit: Six cable/bus-bar fixing screws. Six plastic caps for cable/bus-bar fixing screws. Specifications are subject to change without notice Protection degree Cable diameter Bus-bar size Weight Two panel mounting fixing clips. 1 A secondary current, Tropicalization -25°C to +60°C (-13°F to 140°F) (R.H. < 90% non condensing @ 40°C) -30°C to +70°C (-22°F to 158°F) (R.H. < 90% non condensing @ 40°C) CE, cUrus and CSA Screw type From 1.5 to 6 mm2 Min/Max screws tightening torque relevant to terminal block screws: From 1 to 2 Nm Max screws tightening torque relevant to the cable/bus-bar fixing screws: 0,3 Nm IP00 IP20 (with sealable terminal block covers + wire termi nals) Max. 23 mm Max. 20x5 mm From 150 to 200 g Output Specifications Rated secondary current CTD-1X DS ENG 140116 5 A or 1 A 1 CTD-1X Range Table Model CTD-1X from 50A to 100A Primary Burden (VA) Current A CL 0.5 CL 1 CL 3 50 (@60°C/140°F) 1 1.25 60 (@60°C/140°F) 1 1.25 70 (@60°C/140°F) 1.5 1.75 75 (@60°C/140°F) 1 1.25 1.75 80 (@60°C/140°F) 1.25 1.5 2 100 (@60°C/140°F) 1.5 1.75 2.25 Model CTD-1X from 120A to 300A Primary Burden (VA) Current A CL 0.5 CL 1 CL 3 120 (@60°C/140°F) 1.75 2 2.5 125 (@60°C/140°F) 2 2.25 2.75 150 (@60°C/140°F) 2.25 2.5 3 160 (@60°C/140°F) 2.5 2.75 3.25 200 (@60°C/140°F) 3 3.25 3.75 250 (@50°C/122°F) 4.5 4.75 5.25 300 (@50°C/122°F) 5 5.5 6 Benefits 1 2 3 4 5 6 7 8 9 10 Dimensions (mm) 44 30 27 Wiring Diagram S1 3,3 83,6 φ2 65,2 • Easy and quick mounting either on a panel or on a DIN-rail (see figure 1-2). • Protection of screw terminals using specific sealable covers to assure always the best safety (see figure 3). • Bridging of current transformer output without changing the connection of the secondary, so to avoid any output overvoltage during either the maintenance or the installation procedure (see figure 4). • Easy output and earth connection (see fig. 5). • Screw terminals compatible with any kind of wire terminals (see figure 6-7-8-9). • Multiple screws provided with insulation caps to grant a strong and reliable fixing of the current transformer to the bus-bar (see figure 10). S2 22 L N 2 44 P1 P2 69,2 46 Specifications are subject to change without notice CTD-1X DS ENG 140116
advertisement
* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
Related manuals
advertisement