L OGO! Innovative
Switching & Control
Ethernet capability – up to 8 connections
LOGO! 0BA7 supports SIMATIC S7 Ethernet communication via TCP/IP.
Introduction
Getting started
Integrated
functions
Operation on
device
One LOGO! 0BA7 can establish up to 8
communication connections with other SIMATIC
participants via ethernet.
You can select the following communication
parameters:
LOGO! 0BA7 additionally supports
an ethernet connection to a PC
running the LOGO!Soft Comfort V7.0
programming software.
other LOGO! 0BA7 controllers
SIMATIC S7 controllers with ethernet access
SIMATIC HMIs with ethernet access
LOGO! Soft
Comfort V7.0
DVD
Communication
s
© Siemens AG 2012 – Subject to change
LOGO! Logic Module
I IA AS S MP1
Simultaneous use of the office network and LOGO! communication
via an USB
Ethernet adapter
Introduction
Getting started
Integrated
functions
To use the office network and LOGO! Communication at the same time it is useful to add a
new Ethernet interface via a USB
Ethernet adapter.
1.
Plug the USB Ethernet adapter into a USB port of your PC.
2.
Insert the enclosed driver CD-ROM into the CD-ROM drive of your computer.
3.
The Found New Hardware Wizard opens. Select the Recommended installation and
click Next >.
4.
The required driver for your operating system is selected automatically. Click Next >.
5.
After installing the driver, close the Found New Hardware Wizard by clicking on Finish.
Operation on
device
LOGO! Soft
Comfort V7.0
Communication
© Siemens AG 2012 – Subject to change
LOGO! Logic Module
I IA AS S MP1
How do I set up the communication between my PC and the LOGO!
0BA7?
Introduction
1.
Connect the LOGO! 0BA7 to the functional ground.
2.
Use an RJ45 Ethernet cable to connect LOGO! 0BA7 to the network card to be used
(e.g. USB Ethernet adapter). This requires that the network card has been installed
correctly (administrator rights required!) – (observe the manufacturer‘s installation
instructions!).
3.
LOGO! 0BA7 features a connection status LED (LINK) and a send and receive LED
(Rx/Tx) to verify the communication status.
Getting started
Integrated
functions
Operation on
device
DVD
LOGO! Soft
Comfort V7.0
Communication
s
Functional ground
RJ45 Ethernet cable
Link status LED
© Siemens AG 2012 – Subject to change
LOGO! Logic Module
I IA AS S MP1
IP address assignment of LOGO! 0BA7
1.
Introduction
Getting started
>Program..
Card..
Setup..
Start
Integrated
functions
Operation on
device
>Network..
Diagnostic..
LOGO! Soft
Comfort V7.0
2.
3.
4.
With the LOGO! 0BA7 in Stop mode, navigate to the Network menu
item.
Here you find the settings of the IP address, the subnet mask and the
gateway.
Use the OK button to enter the editing mode of the network settings.
Customize the network settings as desired.
>IP address
Set mode
1
IP address
169.000.000.
001
2
Subnet mask
255.000.000.
000
Communication
3
Gateway
000.000.000.
000
OK
OK
OK
Editing mode
Editing mode
Editing mode
© Siemens AG 2012 – Subject to change
LOGO! Logic Module
I IA AS S MP1
IP address assignment of the PC
1.
Introduction
2.
Getting started
3.
Integrated
functions
4.
1.
Operation on
device
In Windows click Start -> Settings -> Control Panel
to access the Network Connections.
Here, select the HighSpeed USB-Ethernet Adapter
and click the right mouse button to open the
Properties.
Open the Properties of the Internet Protocol
(TCP/IP).
Assign an IP address within the Subnet mask of the
LOGO! 0BA7 and apply the settings by clicking on
OK and Close.
LOGO! Soft
Comfort V7.0
Communication
2.
4.
3.
© Siemens AG 2012 – Subject to change
LOGO! Logic Module
I IA AS S MP1
Online test
1.
Introduction
Getting started
In LOGO!Soft Comfort
open the menu item Tools ->
Transfer -> Configure Network
Address… .
1.
Click the Select
button.
Integrated
functions
Operation on
device
LOGO! Soft
Comfort V7.0
1.
Insert the IP
configuration
with the settings
for your LOGO!
0BA7 by clicking
on the Add
button and
confirm with OK.
1.
Click the Detect button to check the online
status. The status Yes is displayed in case
of availability.
Communication
© Siemens AG 2012 – Subject to change
LOGO! Logic Module
I IA AS S MP1
Constants/Network - Overview
Network
Introduction
Getting started
Network node
Analog
network node
Integrated
functions
Operation on
device
LOGO! Soft
Comfort V7.0
Slave output
Communication
Analog
slave output
© Siemens AG 2012 – Subject to change
LOGO! Logic Module
I IA AS S MP1
Network – Network node
Introduction
Function description:
The “Network node” function allows you to read
and process binary variables.
You can call up to 64 “network nodes”.
You can read either bits from the VM section of the
LOGO! 0BA7 or inputs or outputs of a slave.
Getting started
Integrated
functions
Operation on
device
To read binary variables from the VM section, enter
the VB address (0 to 850) and the bit to be read.
LOGO! Soft
Comfort V7.0
Communication
To read out the digital periphery of a slave, you
have to specify the IP address of the slave, the
block type (input or output) and the block number
(I1 to I24 for inputs or Q1 to Q16 for outputs).
© Siemens AG 2012 – Subject to change
LOGO! Logic Module
I IA AS S MP1
Network – Analog network node
Function description:
Introduction
The “Analog network node” function enables you
to read and process variables of the data type
“Word”.
You can call up to 32 “analog network nodes”.
You can read either words from the VM section of
the LOGO! 0BA7 or analog inputs or outputs of a
slave.
Getting started
Integrated
functions
Operation on
device
To read words from the VM section, you have to
specify the VW address (0 to 849).
LOGO! Soft
Comfort V7.0
Communication
To read the analog periphery of a slave, you have to
specify the IP address of the slave, the block type
(analog input or analog output) and the block
number (AI1 to AI8 for analog inputs or AQ1 to AQ2
for analog outputs).
© Siemens AG 2012 – Subject to change
LOGO! Logic Module
I IA AS S MP1
Network – Slave output / Analog slave output
Introduction
Getting started
Function description:
Integrated
functions
Operation on
device
LOGO! Soft
Comfort V7.0
Communication
To describe the outputs (digital or analog) of a
slave LOGO! 0BA7, use the blocks “Slave output”
or “Analog slave output”.
You can call up to 64 “Slave output” blocks and up
to 16 “Analog slave output” blocks in one master.
You have to specify the IP address of the slave and
the number of the digital “Slave output” (Q1 to Q16)
or “Analog slave output” (AQ1 to AQ2) to be
described.
© Siemens AG 2012 – Subject to change
LOGO! Logic Module
I IA AS S MP1
Special functions - overview
Timer
Introduction
Analog
Analog filter
Getting started
Astronomical clock
Integrated
functions
Operation on
device
Max/Min
LOGO! Soft
Comfort V7.0
Stopwatch
Communication
Average value
© Siemens AG 2012 – Subject to change
LOGO! Logic Module
I IA AS S MP1
Timer – Astronomical clock
Introduction
The output of the Astronomical timer is active from
sunrise to sunset. Therefore you have to configure
the place of installation.
Getting started
Integrated
functions
morning
Operation on
device
LOGO! Soft
Comfort V7.0
Communication
evening
Function description:
After configuration of the place of
installation the location, the
corresponding latitude and longitude
are taken over. This determines the
starting time (sunrise) and the
stopping time (sunset).
You can select the location from a list
of major cities or you can define your
own locations by entering the
longitude and latitude.
© Siemens AG 2012 – Subject to change
LOGO! Logic Module
I IA AS S MP1
Timer – Stopwatch
Introduction
The output provides the elapsed or stopped time as
an analog value.
Getting started
Integrated
functions
Operation on
device
LOGO! Soft
Comfort V7.0
Function description:
The stopwatch is activated via “En”.
The elapsed time is output as analog
value. Once the “Lap” input is active,
the stopped intermediate time is
output and the stopwatch continues in
the background. Once “Lap” becomes
inactive, the elapsed time is output
again. Activating the input “R” resets
all times.
Communication
© Siemens AG 2012 – Subject to change
LOGO! Logic Module
I IA AS S MP1
Analog – Analog filter
Introduction
Getting started
Integrated
functions
Function description:
The analog filter is used to smooth an
analog input signal.
The analog outputs provides the average
value of the analog input signal after a
configurable number of samples.
Operation on
device
LOGO! Soft
Comfort V7.0
Diagram:
Communication
© Siemens AG 2012 – Subject to change
LOGO! Logic Module
I IA AS S MP1
Analog – Max/Min
Introduction
Function description:
The “Max/Min” function block
saves the minimum or maximum
value of the analog input signal
“Ax” and provides this value at
the analog output depending on
the set mode.
Getting started
Integrated
functions
Operation on
device
Mode:
Possible settings: 0, 1, 2, 3
Mode = 0: AQ = Min
Mode = 1: AQ = Max
Mode = 2 and S1= 0 (low): AQ = Min
Mode = 2 and S1= 1 (high): AQ = Max
Mode = 3: AQ = current value of Ax
Diagram:
LOGO! Soft
Comfort V7.0
Communication
© Siemens AG 2012 – Subject to change
LOGO! Logic Module
I IA AS S MP1
Analog – Average value
Introduction
Getting started
Integrated
functions
Operation on
device
Function description:
The “Average value” function block
calculates the mean value of the
analog input signal as a function of the
set sampling time and the number of
samples.
The mean value is provided at the
output.
Diagram:
LOGO! Soft
Comfort V7.0
Communication
© Siemens AG 2012 – Subject to change
LOGO! Logic Module
I IA AS S MP1
Miscellaneous – Message texts
Inserting a symbol into the message
Introduction
Click the “Symbol” button to obtain additional ASCII symbols depending on the selected
character set which you can insert into your message text.
Getting started
Integrated
functions
Operation on
device
LOGO! Soft
Comfort V7.0
Communication
© Siemens AG 2012 – Subject to change
LOGO! Logic Module
I IA AS S MP1
Miscellaneous – Shift register
for 0BA7 and higher: 4 shift registers instead of one
Introduction
Function description:
Diagram:
You can select the desired shift register (1 to 4)
using the shift register index.
Getting started
Integrated
functions
Operation on
device
LOGO! Soft
Comfort V7.0
Communication
With the rising edge at the input “Trg”, the
function reads the value of the input “In”.
Depending on the shift direction, this value is
included into the shift register bit Sx.1 or Sx.8
(x = index) :
Upward shifting: Sx.1 takes on the value of the
input “ In”; the previous value of Sx.1 is shifted to
Sx.2; the previous value of Sx.2 is shifted to Sx.3,
etc.
The value of the configured shift register bit is
output at the output Q. If the retentivity is not
activated, the shift function will start at Sx.1 or
Sx.8 following a power failure. The activated
retentivity always applies to all shift register bits.
© Siemens AG 2012 – Subject to change
LOGO! Logic Module
I IA AS S MP1
Data Log
Introduction
Getting started
Integrated
functions
Operation on
device
Function description:
The Data Log function allows you to record up to 31 variables.
You can record digital/ analog inputs and outputs, flags, and parameters of used functions.
A rising edge at the “En” input, triggers the recording of a dataset with time stamp. The data log
file is saved as .csv-file in the load memory of the LOGO! 0BA7 or on a SD card.
When saving in LOGO!, only one .csv-file with a maximum of 340 datasets is recorded as ring
buffer.
LOGO! SoftComfort V7.0 enables you to read the data log files and open them using Microsoft
Excel.
LOGO! Soft
Comfort V7.0
Communication
© Siemens AG 2012 – Subject to change
LOGO! Logic Module
I IA AS S MP1
Data Log
Configuring the Data Log
Introduction
1. Create a trigger
variable at the
input “En”.
Getting started
Integrated
functions
Operation on
device
LOGO! Soft
Comfort V7.0
Communication
2. Open the block
properties of the
“Data Log”
function.
4. Add the selected
parameter.
3. Select the block
and parameter to
be recorded.
© Siemens AG 2012 – Subject to change
LOGO! Logic Module
I IA AS S MP1
Data Log
Upload Data Log
Introduction
1. In LOGO! SoftComfort V7.0, open the Upload Data Log… menu item under Tools ->
Transfer.
Getting started
Integrated
functions
2. Select the LOGO! 0BA7
to be loaded via the IP address.
Operation on
device
LOGO! Soft
Comfort V7.0
Communication
3. To read the data log file, switch the
LOGO! 0BA7 to STOP.
4. Select a location for saving the .csv-file.
© Siemens AG 2012 – Subject to change
LOGO! Logic Module
I IA AS S MP1
Data Log
Opening Data Log
Introduction
1. Open an empty worksheet in Microsoft Excel and select the menu item Import Data…
under Data -> Import External Data.
Getting started
Integrated
functions
Operation on
device
2. Select the loaded .csv-file.
LOGO! Soft
Comfort V7.0
Communication
3. Navigate to step 2 of the
Text Import Wizard and
select Comma as delimiter.
Finish the Text Import Wizard.
© Siemens AG 2012 – Subject to change
LOGO! Logic Module
I IA AS S MP1
UDF
Creating a UDF
Introduction
Getting started
Creating UDFs (User-defined Function blocks) facilitates programming in
LOGO! SoftComfort V7.0.
You can combine complex function interconnections to a separate function block which you
can save and call multiple times in the program.
Furthermore, the clarity of the program is much improved.
You can create a UDF diagram (UDF) via File -> New.
A rectangle then opens in which you can create the desired
switching program.
Or you select all blocks you want to combine to a UDF in an
existing switching program and select Create UDF in the context
menu opened by clicking the right mouse button.
Integrated
functions
Operation on
device
LOGO! Soft
Comfort V7.0
Communication
© Siemens AG 2012 – Subject to change
LOGO! Logic Module
I IA AS S MP1
UDF
Restrictions for a UDF
The creation of UDFs is subject to the following restrictions:
Introduction
Getting started
Digital and analog inputs and outputs, system flags, shift registers, PI controllers, Data Log,
and message texts cannot be integrated into a UDF.
A UDF can have a maximum of 8 input and 4 output connectors (analog and digital).
You can lead out a maximum of 8 editable parameters.
Integrated
functions
But you can insert UDFs
that are already created
into a new UDF.
Operation on
device
LOGO! Soft
Comfort V7.0
Communication
The transitions to the
unselected part of your
switching program are
defined as input or
output connectors of the
UDF.
© Siemens AG 2012 – Subject to change
LOGO! Logic Module
I IA AS S MP1
UDF
Edit UDF properties
Introduction
Via Edit -> Edit UDF properties you can protect the UDF you have created by password, assign
specific names for the UDF, the input and output terminals and define the editable parameters
of your UDF.
Getting started
Integrated
functions
Operation on
device
LOGO! Soft
Comfort V7.0
Communication
© Siemens AG 2012 – Subject to change
LOGO! Logic Module
I IA AS S MP1
UDF
Saving UDF
Introduction
You can save your UDF using the
The UDF is saved in the lma format.
icon or via File -> Save as….
Getting started
Integrated
functions
Operation on
device
LOGO! Soft
Comfort V7.0
Communication
© Siemens AG 2012 – Subject to change
LOGO! Logic Module
I IA AS S MP1
UDF
Add UDF in UDF Library
Introduction
Stored UDFs can be inserted into the UDF Library in LOGO! SoftComfort V7.0 via
Tools -> Options… -> UDF -> Add UDF.
Getting started
Integrated
functions
Operation on
device
LOGO! Soft
Comfort V7.0
Communication
© Siemens AG 2012 – Subject to change
LOGO! Logic Module
I IA AS S MP1
UDF
Using UDFs in the circuit program
Introduction
The UDFs that have been created and inserted are listed under UDF in the tree structure in
LOGO! SoftComfort V7.0.
You can use them in the switching program by dragging & dropping.
In the Block Properties… you can edit predefined parameters.
Getting started
Integrated
functions
Operation on
device
LOGO! Soft
Comfort V7.0
Communication
© Siemens AG 2012 – Subject to change
LOGO! Logic Module
I IA AS S MP1
UDF
Expanding & updating UDFs
Introduction
1.
2.
3.
Getting started
4.
You can edit included UDFs by right click -> Expand UDF.
The changed UDF can be saved under a new version.
A red exclamation mark in the switching program signals that a newer version of the
UDF is available in the UDF Library.
Via right click -> Update UDF the new version of the UDF is applied in the circuit
program.
Integrated
functions
3.
Operation on
device
LOGO! Soft
Comfort V7.0
1.
Communication
4.
2.
© Siemens AG 2012 – Subject to change
LOGO! Logic Module
I IA AS S MP1
LOGO! ..0BA7 – Start screen options
Introduction
LOGO! 0BA7 and the ES7 version of the LOGO! TD provides the additional start screen option
defaults to the parameter assignment menu.
Getting started
s
Integrated
functions
Operation on
device
LOGO! Soft
Comfort V7.0
s
Stop
Set Param
>Set ..
Prg Name
LOGO!
Mo 09:30
2011-03-07
ESC OK
ESC OK
LOGO!
s
s
I:
0.. 123456789
1..0123456789
2..01234
Clock ..
Contrast
>StartScreen
ESC OK
Communication
LOGO!
s
ESC OK
LOGO!
s
>Stop
Set Param
Set ..
Prg Name
Clock
Input DI
>Menu
*
ESC OK
ESC OK
LOGO!
LOGO!
© Siemens AG 2012 – Subject to change
LOGO! Logic Module
I IA AS S MP1
Simulate out of network
Introduction
LOGO!
LOGO! communication can also be simulated offline using the
Simulate out of network button.
Getting started
Integrated
functions
Operation on
device
LOGO! Soft
Comfort V7.0
Communication
© Siemens AG 2012 – Subject to change
LOGO! Logic Module
I IA AS S MP1
Data Table
Introduction
The data table
enables you to view variables of the memory sections (VM, inputs,
outputs, flags) during the simulation or the online test, and even to describe VM variables.
Getting started
Integrated
functions
Operation on
device
LOGO! Soft
Comfort V7.0
Communication
The data table supports
these address ranges:
Address Type
Bit
VB
VW
VD
IB
QB
MB
Range
none
0 to 850
0 to 849
0 to 847
0 to 2
0 to 1
0 to 3
© Siemens AG 2012 – Subject to change
LOGO! Logic Module
I IA AS S MP1
I/O Status Overview
Introduction
Via Tools -> Transfer -> I/O Status… you can view the changes of all inputs and outputs as
a function of time.
Additionally, you can record log file in .csv-format during activation of the I/O status.
Getting started
Integrated
functions
Operation on
device
LOGO! Soft
Comfort V7.0
Communication
© Siemens AG 2012 – Subject to change
LOGO! Logic Module
I IA AS S MP1
Diagnostic
Introduction
Via Tools -> Transfer -> Diagnostic… you can view error messages that have occurred.
Getting started
Integrated
functions
Operation on
device
LOGO! Soft
Comfort V7.0
Communication
© Siemens AG 2012 – Subject to change
LOGO! Logic Module
I IA AS S MP1
LOGO!
LOGO! communication (master – slave)
Introduction
Getting started
Integrated
functions
During master-slave communication, the slave LOGO! 0BA7 acts as extension module
without a program of its own.
The master describes or reads the digital and analog inputs and outputs of the slave.
Each slave can be extended within the maximal extension, but a max. of 32 values can be
transferred.
Use the network blocks for the master-slave communication.
When using these blocks, an ethernet connection to the slave is created automatically.
This connection requires you to specify the module address of the master.
Operation on
device
Master
(IP: 169.0.0.1)
LOGO! Soft
Comfort V7.0
Communication
© Siemens AG 2012 – Subject to change
LOGO! Logic Module
I IA AS S MP1
LOGO!
Introduction
Getting started
LOGO! communication (slave mode)
For the master-slave communication to work, the communication partner must be
switched to slave mode.
This can be done in LOGO! SoftComfort V7.0 or directly via the menu navigation of
LOGO! 0BA7.
Integrated
functions
Operation on
device
LOGO! Soft
Comfort V7.0
Communication
>Program..
Card..
Setup..
Start
>Network..
Diagnostic..
IP address
>Set mode
Normal
*
>Slave
Password
>Config
Master IP
169.000.000.
001
© Siemens AG 2012 – Subject to change
LOGO! Logic Module
I IA AS S MP1
LOGO!
LOGO! communication (client – server)
Adding a connection
Introduction
Getting started
During client-server communication, the server provides its data areas for the client to write to
or read.
A LOGO! 0BA7 can be client and server at the same time.
It is defined for each configured connection whether the LOGO! 0BA7 acts as client or server.
Double-click on the added connection to open the address configuration.
Integrated
functions
Operation on
device
LOGO! Soft
Comfort V7.0
Communication
© Siemens AG 2012 – Subject to change
LOGO! Logic Module
I IA AS S MP1
LOGO!
LOGO! communication (client – server)
Configuring the connection
Introduction
Getting started
Define the connection as client or server connection in the respective program.
You have to specify the IP address and the TSAP (Transfer Service Access Point) of the
communication partner.
Client (IP: 169.0.0.1)
Integrated
functions
Operation on
device
LOGO! Soft
Comfort V7.0
Server (IP: 169.0.0.2)
Communication
© Siemens AG 2012 – Subject to change
LOGO! Logic Module
I IA AS S MP1
LOGO!
LOGO! communication (client – server)
Data transfer
Introduction
Getting started
Integrated
functions
You have to additionally specify the data transfers on the client side.
You can define up to 32 data transfers.
You can transfer up to 212 bytes in each data transfer.
One byte is the smallest amount of data to be transferred.
Define the direction (read or write) for each data transfer.
Specify the data length to be transmitted in bytes (1 to 212).
Specify the local start address byte (0 to 850).
Specify the start address byte of the server (0 to 850).
Operation on
device
LOGO! Soft
Comfort V7.0
Communication
The Keep-Alive function serves as connection check.
When activated, the connection is checked every 5 seconds.
© Siemens AG 2012 – Subject to change
LOGO! Logic Module
I IA AS S MP1
LOGO!
LOGO! communication (client – server):
Variable Memory Configuration
Introduction
Getting started
Integrated
functions
Depending on the data direction, the parameter VM mapping has to be assigned on the
sending side:
on the server side when reading from the server
on the client side when writing to the server
Up to 64 parameters of the special function blocks used in the program circuit can be
assigned to the VM area.
1.
Select the used special function block from your program.
2.
Select the parameter to be transferred (the data type is preset).
3.
Determine the start address in the VM area.
Operation on
device
LOGO! Soft
Comfort V7.0
Communication
© Siemens AG 2012 – Subject to change
LOGO! Logic Module
I IA AS S MP1
LOGO!-LOGO! communication (client – server):
Example 1: Writing the analog input of the client in the server
Introduction
Analog input AI1 of the client is to be transmitted to the server and there be output at the
analog output AQ1.
1.
The analog input is submitted to the special function Analog Amplifier with
the gain factor Gain = 1.
Getting started
Integrated
functions
2.
Client
3.
Operation on
device
The output of the analog amplifier Ax, amplified is
written to VW 0 through the variable memory
configuration.
A data transfer to the server with the assignment
VW 0 = VW 0 is defined in the client connection.
LOGO! Soft
Comfort V7.0
Communication
Server
4.
The VW 0 is provided at output AQ1 on the server
side using the analog network node.
© Siemens AG 2012 – Subject to change
LOGO! Logic Module
I IA AS S MP1
LOGO!-LOGO! communication (client – server):
Example 2: Reading a digital input from the server (1)
Introduction
Input I1 of the server is to be read and its status is to be output at the client‘s Q4 output.
1.
Write the program for the server and define the IP-address
Getting started
2.
Integrated
functions
Add a connection
3.
Configure the connection as Server
Operation on
device
LOGO! Soft
Comfort V7.0
Communication
© Siemens AG 2012 – Subject to change
LOGO! Logic Module
I IA AS S MP1
LOGO!-LOGO! communication (client – server):
Example 2: Reading a digital input from the server (2)
1.
Write the program for the client and define the IP-address
Introduction
2.
Getting started
Add a connection
3.
Integrated
functions
Configure the connection as Client
and select
READ, 1 Byte, address in the Client VB0 and
address in the Server input byte 1 (IB0)
Operation on
device
LOGO! Soft
Comfort V7.0
Communication
© Siemens AG 2012 – Subject to change
LOGO! Logic Module
I IA AS S MP1
LOGO!-LOGO! communication (client – server):
Example 2: Reading a digital input from the server (3) Simulation
Introduction
Input I1 of the server is to be read and its status is to be output at the client‘s Q4 output.
Simulation of both programs simultaneously
Getting started
Integrated
functions
Operation on
device
1.
Switch the display of LOGOI! Soft Comfort to
„internal windows“ and show both programs
2.
Switch both programs to simulation mode and
activate in both windows the network simulation
3. Activating input I1 of the
server should activate
the network input and
the output Q4 of the
client
LOGO! Soft
Comfort V7.0
Communication
© Siemens AG 2012 – Subject to change
LOGO! Logic Module
I IA AS S MP1
LOGO!-S7-1200 communication (client – server)
Configuring the connection
Introduction
Getting started
The S7-1200 only offers the server functionality in the firmware V1.x.
Consequently, the communication with the S7-1200 requires a client connection to be
configured on the LOGO! 0BA7 side.
S7-1200
Server (IP: 169.0.0.3)
Client
Integrated
functions
Operation on
device
LOGO! Soft
Comfort V7.0
Communication
Enter 03.00 as server TSAP for the S7-1200.
Specify the IP address of the S7-1200.
Access to the S7-1200 data is accomplished using data blocks.
These must not be Symbolic access only.
The variables selected for data transfer must be created on the S7-1200 side.
© Siemens AG 2012 – Subject to change
LOGO! Logic Module
I IA AS S MP1
LOGO!-HMI communication (server – client)
Configuring a connection
Introduction
Getting started
Integrated
functions
A server connection must be configured when connecting an HMI to the LOGO! 0BA7.
Set a checkmark in the box Connect with an Operator Panel (OP).
Enter 02.00 as client TSAP for the HMI.
Specify the IP address of the HMI.
LOGO! 0BA7
Server (IP: 169.0.0.1)
HMI
Client (IP: 169.0.0.10)
Operation on
device
LOGO! Soft
Comfort V7.0
Communication
To configure the HMI, you need WinCC flexible or the TIA Portal V11.
Select the SIMATIC S7 200 communication driver to configure the connection
with the LOGO! 0BA7.
© Siemens AG 2012 – Subject to change
LOGO! Logic Module
I IA AS S MP1
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertisement