Peerless-AV LCC-18 Flat Panel Ceiling Mount Installation Instructions
PEERLESS-AV LCC-18 offers versatile mounting solutions for your LCD screens up to 29" with its adjustable height range, tilt functionality, and multiple orientation options. Enjoy 360-degree swivel action for optimal viewing angles and easily mount your screen in either standard or face-down positions. The included hardware supports both wood and concrete installations, ensuring a secure and stable setup.
Advertisement
Advertisement
Installation and Assembly:
Ceiling mount for LCD screens up to 29"
Models: LCC-18, LCC-18-S, LCC-36, LCC-36-S, LCC-36-W
Patent Pending
Features:
• Comes in two adjustable height ranges (in 1" increments): 18"-30" and
36"-48".
• -5° to +20° adjustable tilt
.
• Screen can be mounted in standard position or face-down.
• Portrait or landscape orientation.
• Ceiling plate included.
• Hardware included for wood or concrete installations.
• Theft resistant security fasteners included.
• VESA
®
75/100 mm compliant (Non-VESA adapter offered separately).
• Comes in black or silver. LCC 36-W offered in white.
• 360° swivel action.
Max UL Load Capacity: 40 lb (18.1 kg)
2300 White Oak Circle • Aurora, Il 60502 • (800) 865-2112 • Fax: (800) 359-6500 • www.peerless-av.com
ISSUED: 09-27-04 SHEET #: 100-9004-8 10-08-12
Note: Read entire instruction sheet before you start installation and assembly.
WARNING
• Do not begin to install your Peerless product until you have read and understood the instructions and warnings contained in this Installation Sheet. If you have any questions regarding any of the instructions or warnings, for US customers please call Peerless customer care at 1-800-865-2112, for all international customers, please contact your local distributor.
• This product should only be installed by a qualifi ed professional.
• Make sure that the ceiling will safely support the combined load of the equipment and all attached hardware and components.
• Never exceed the Maximum UL Load Capacity. See page 1.
• If mounting to wood ceiling joists, make sure that mounting screws are anchored into the center of the joists. Use of an "edge to edge" stud fi nder is highly recommended.
• Always use an assistant or mechanical lifting equipment to safely lift and position equipment.
• Tighten screws fi rmly, but do not overtighten. Overtightening can damage the items, greatly reducing their holding power.
Accessories
•
Lightweight Adjustable Suspended Ceiling Kit (CMJ 500)
•
Lightweight Suspended Ceiling Kit (CMJ 455)
•
Accessory Pack for CMJ 455 (ACC455)*
•
Lightweight Cathedral Ceiling Plate (ACC912)*
•
Unistrut or Structural Ceiling Plates (CMJ 300, CMJ 310)*
•
Anti-Vibration Ceiling Plates (ACC845)*
•
I-Beam Clamps (ACC558, ACC559)
•
Truss Ceiling Adapter (ACC557)*
•
Unistrut Adapter (ACC550)
•
Escutcheon Ring (ACC640)*
*
not evaluated by UL
Tools Needed for Assembly
• stud fi nder ("edge to edge" stud fi nder is recommended)
• phillips screwdriver
• drill with 5/16", 3/8", and 5/32" drill bits
•
Round Ceiling Plate (ACC570)
•
Cord Wrap (ACC852(W)(S))*
•
Fixed Length 1 1/2" Extension Columns
•
Adjustable Length 1 1/2" Extension Columns
•
Extension Column Stabilizer Kit (ACC050)*
•
Extension Column Connector (ACC109)
•
1/2" Threaded Rod (ACC820)*
•
Threaded Rod Adapter (ACC810)*
•
Non-VESA Adapter Plates (LC models)
*
Table of Contents
Parts List.................................................................................................................................................................................3
Installation to Wood Joist Finished Ceilings, Exposed Wood Joists, or Wood Beam Ceilings ...............................................4
Installation to Concrete Ceilings .............................................................................................................................................5
Installing Reducer ...................................................................................................................................................................6
Flush Mount Installation..........................................................................................................................................................7
Installation to Threaded Rod ..................................................................................................................................................7
Installation to Extension Column ............................................................................................................................................8
Installation to Lightweight Suspended Ceiling Plate ...............................................................................................................9
Attaching Tilt Bracket to LCD Screen ................................................................................................................................. 10
Installation of screen in the Vertical Position ........................................................................................................................11
Installation of screen in the Horizontal Position ................................................................................................................... 12
2 of 12
ISSUED: 09-27-04 SHEET #: 100-9004-8 10-08-12
Parts List
Description
A
tube assembly
B
ceiling plate
C
tilt bracket
D
reducer
E
#14 x 2.5" wood screw
F
M5 x 12 mm socket pin screw
G
4 mm security allen wrench
H
concrete anchor
I
10-32 x 3/8" socket set screw
J
hex wrench
K
M4 x 10 mm socket pin screw
L
M4 x 12 mm serrated washer head socket pin screw
M M4 x 20 mm socket pin screw
N
#10-32 x 3/16" slotted set screw
O
retaining spacer
P
M5 x 10 mm socket pin F-type screw
Q
cable tie
LCC-18
Qty. Part #
LCC-18S
Part #
LCC-36
Part #
LCC-36S
Part #
1 055-1520
1 580-1042
1 055-1551
1 580-1009
055-4520
580-4042
055-4551
580-4009
055-1521
580-1042
055-1551
580-1009
055-4521
580-4042
055-4551
580-4009
2 5S1-015-C03 5S1-015-C04 5S1-015-C03 5S1-015-C04
4 520-1064 520-2064 520-1064 520-2064
1 560-9646
2 590-0320
1 520-1127
560-9646
590-0320
500-2018
560-9646
590-0320
520-1127
560-9646
590-0320
500-2018
1 560-1034
4 520-1060
4 510-1079
4 520-1061
1 520-1187
4 590-5005
1 520-1164
3 590-1168
560-1034
520-2060
510-2079
520-2163
520-2187
590-5003
520-2031
590-1168
560-1034
520-1060
510-1079
520-1061
520-1187
590-5005
520-1164
590-1168
560-1034
520-2060
510-2079
520-2163
520-2187
590-5003
520-2031
590-1168
A B C
D
E
M
H
G
J
I
N
F
O
3 of 12
K
L
P
Q
ISSUED: 09-27-04 SHEET #: 100-9004-8 10-08-12
Installation to Wood Joist Finished Ceilings,
Exposed Wood Joists, or Wood Beam Ceilings
1
Drill two 5/32" (4 mm) dia. holes to a minimum depth of 2.5" (64 mm). Attach ceiling plate (B) with two #14 x 2.5" (6 mm x 65 mm) wood screws (E) as shown using 3/8" (10 mm) socket wrench. Tighten wood screws (E) so ceiling plate (B) is fi rmly attached.
WARNING
• Tighten wood screws so that ceiling plate is fi rmly attached, but do not overtighten. Overtightening can damage the screws, greatly reducing their holding power.
• Never tighten in excess of 80 in • lb (9 N.M.).
• Make sure that mounting screws are anchored into the center of the joist. The use of an "edge to edge" stud fi nder is highly recommended.
Skip to step 2 on page 6.
WOOD
JOIST
CEILING
B
E
E
4 of 12
ISSUED: 09-27-04 SHEET #: 100-9004-8 10-08-12
Installation to Concrete Ceilings
1
Drill two 5/16" (8 mm) dia. holes to a minimum depth of 2.5" (64 mm). Attach ceiling plate (B) using two concrete anchors (H) and #14 x 2.5" wood screws (E) as shown in Illustration A and 1, 2, and 3 (below).
Tighten all fasteners.
1
WARNING
• Tighten wood screws fi rmly, but do not overtighten.
Overtightening can damage the bolt, greatly reducing its holding power.
• Never tighten in excess of 80 in • lb (9 N.M.).
Drill holes and insert anchors (H).
2
B
H
concrete surface
E
H
Place plate (B) over anchors (H) and secure with screws (E).
3
WARNING
• Concrete anchors are not intended for attachment to concrete wall covered with a layer of plaster, drywall, or other fi nishing material. If mounting to concrete wall covered with plaster/drywall is unavoidable, plaster/drywall (up to 5/8" thick) must be counterbored as shown below. If plaster/drywall is thicker than 5/8", custom fasteners must be supplied by installer (not evaluated by UL).
wall plate
INCORRECT
concrete wall plate
CORRECT
concrete
Tighten all fasteners.
CONCRETE CEILING
H
plaster/ dry wall plaster/ dry wall
B
E
Illustration A
5 of 12
ISSUED: 09-27-04 SHEET #: 100-9004-8 10-08-12
Installing Reducer
2
Thread reducer (D) onto tube assembly (A) until tight.
Insert set screw (I) into reducer as shown in fi gure 2.1.
Tighten screw using hex wrench (J). Note: Set screw
(I) is used to jam against the threads of tube assembly to prevent any excess movement.
To adjust height of tube assembly (A), remove socket pin screw and two lock washers using 4 mm security allen wrench (G) and adjust to desired height as shown in fi gure 2.2.
D fi g. 2.1
I
A
LOCK WASHERS
SOCKET PIN SCREW
A fi g. 2.2
6 of 12
ISSUED: 09-27-04 SHEET #: 100-9004-8 10-08-12
Flush Mount Installation
3
Screw reducer (D) into ceiling plate (B) until notch in reducer is aligned with one of the four holes in ceiling plate and set screw (I) is at least partially covered by ceiling plate as shown in fi gure 3.1.
Secure reducer with one M5 x 10 mm F-type socket pin screw (P) using security allen wrench
(G) as shown in fi gure 3.2. Note: Slotted set screw (N) is used to jam against the threads of the reducer to prevent any excess movement of the tube assembly (A). Do not overtighten screw; overtightening screw will damage threads making it diffi cult to separate the products.
Skip to step 4 on page 10.
B
D
N
P
A fi g. 3.2
I fi g. 3.1
Installation to
Threaded Rod
Accessory ACC810 (not evaluated by UL), threaded rod adapter, is required.
3
Screw threaded rod adapter (ACC810) into extension column connector (ACC109). Align slot in threaded rod adapter with one of the top holes in extension column connector. Insert and tighten one #10-32 x
3/8" socket pin screw provided with extension column connector through extension column connector into slot on threaded rod adapter using 4 mm security allen wrench (G). See fi gure 3.3.
Align slot in reducer (D) to one of the bottom holes in extension column connector. Insert and tighten one #10-32 x 3/8" socket pin screw provided with extension column connector through extension column connector into slot in reducer. See fi gure 3.4.
Note: Slotted set screws provided with extension column connector are used to jam against the threads of each connecting joint to prevent any excess movement. Do not overtighten screws; overtightening screws will damage threads making it diffi cult to separate the products.
Skip to step 4 on page 10.
1/2 -13 THREADED
ROD
ACC810 (SOLD
SEPARATELY)
SET
SCREW
SLOT
ACC109
(SOLD SEPARATELY)
SLOT
D
ACC109
SET
SCREW
D
THREADED
ROD
ACC810
SLOT
SOCKET
PIN
SCREW
fi g. 3.3
ACC109
THREADED
ROD
ACC810
SLOT
SOCKET
PIN
SCREW
7 of 12 fi g. 3.4
ISSUED: 09-27-04 SHEET #: 100-9004-8 10-08-12
Installation to Extension Column
3
Screw extension column (EXT or ADJ
Series) to ceiling plate (B). Align the notch with one of the four holes in the ceiling plate and secure extension column with a M5 x 10 mm socket pin screw (P) using security allen wrench
(G). See fi gure 3.5.
Note: Slotted set screw (N) is used to jam against the threads of the reducer to prevent any excess movement of the extension column. Do not overtighten screw; overtightening screw will damage threads making it diffi cult to separate the products.
B
EXTENSION COLUMN
(EXT or ADJ Series)
Sold Separately
P
Screw extension column connector
(ACC109) to extension column. Align slot in extension column with one of the top holes in extension column connector.
Insert and tighten one #10-32 x 3/8" socket pin screw provided with projector through extension column connector into slot on extension column using security allen wrench (G). See fi gure 3.6.
SLOT
Screw reducer (D) to extension column connector. Align reducer to one of the bottom holes in extension column connector. Insert and tighten one #10-
32 x 3/8" socket pin screw provided with connector through extension column connector into slot in reducer using security allen wrench (G). See fi gure 3.7.
EXTENSION COLUMN
CONNECTOR (SOLD
SEPARATELY)
D
Note: Slotted set screws provided with extension column connector are used to jam against the threads of each connecting joint to prevent any excess movement. Do not overtighten screws; overtightening screws will damage threads making it diffi cult to separate the products.
SLOT
EXTENSION
COLUMN
SET SCREW
ACC109
ACC109
Skip to step 4 on page 10.
fi g. 3.5
fi g. 3.6
N
B
EXTENSION
COLUMN
SLOT
SOCKET PIN
SCREW
EXTENSION
COLUMN
SLOT
SET SCREW
D
SOCKET PIN
SCREW
ACC850 - EXTENSION COLUMN
CONNECTOR WITH CORD MANAGEMENT
- MAY BE USED IN PLACE OF EXTENSION
COLUMN CONNECTOR. (SOLD
SEPARATELY)
8 of 12 fi g. 3.7
ISSUED: 09-27-04 SHEET #: 100-9004-8 10-08-12
Installation to Lightweight Suspended Ceiling Plate
3
Refer to instruction sheet for lightweight suspended ceiling plate (CMJ 455) for attachment of ceiling plate to ceiling.
Screw extension column (EXT or ADJ
Series) to
retaining collar in ceiling tray
. Align the notch with one of the four holes in retaining collar and secure extension column with one M5 x 10 mm socket pin screw (P) using security allen wrench (G). See fi gure 3.8.
Note: Slotted set screw (N) is used to jam against the threads of the reducer to prevent any excess movement of the extension column. Do not overtighten screw; overtightening screw will damage threads making it diffi cult to separate the products.
Screw extension column connector to extension column. Align slot in extension column with one of the top holes in extension column connector.
Insert and tighten one 10-32 x 3/8 socket pin screw provided with connector through extension column connector into slot on extension column using security allen wrench. See fi gure
3.9.
Screw reducer (D) to extension column connector. Align slot in reducer to one of the bottom holes in extension column connector. Insert and tighten one 10-32 x 3/8 socket pin screw provided with connector through extension column connector into slot in reducer using security allen wrench. See fi gure 3.10.
LIGHTWEIGHT SUSPENDED
CEILING PLATE (SOLD
SEPARATELY)
EXTENSION COLUMN
(EXT or ADJ Series)
Sold Separately
N
EXTENSION
COLUMN
SET SCREW
SLOT
ACC109
EXTENSION COLUMN
CONNECTOR (SOLD
SEPARATELY)
RETAINING COLLAR
P
EXTENSION
COLUMN (SOLD
SEPARATELY)
fi g. 3.8
SOCKET PIN
SCREW
fi g. 3.9
Note: Slotted set screws provided with extension column connector are used to jam against the threads of each connecting joint to prevent any excess movement. Do not overtighten screws; overtightening screws will damage threads making it diffi cult to separate the products.
SLOT
SLOT
D
ACC109
SET SCREW
EXTENSION
COLUMN
D
SOCKET PIN
SCREW
ACC850 - EXTENSION COLUMN
CONNECTOR WITH CORD
MANAGEMENT - MAY BE USED IN PLACE
OF EXTENSION COLUMN CONNECTOR.
(SOLD SEPARATELY)
9 of 12 fi g. 3.10
ISSUED: 09-27-04 SHEET #: 100-9004-8 10-08-12
Attaching Tilt Bracket to LCD Screen
4
Note: This product is designed to accommodate screens with VESA
®
compliant hole patterns. For safe mounting, please make sure that mounting screws turn at least three complete turns in the screen inserts.
FOR VESA 75 MOUNTING PATTERN:
1) Choose hole pattern indicated below. 2) Attach tilt bracket (C) to back of screen using four M4 x 10 mm screws
(K) as indicated below. 3) If hole pattern is in a pocket, attach tilt bracket to back of screen using four M4 x 20 mm screws (M) and four retaining spacers (O) as indicated below. Tighten all security screws with security allen wrench (G).
C
BOTT
OM OF SCREEN
For screens with a hole
pattern in a pocket, spacers (O) go between tilting bracket (C) and screen.
Note: LCD screen may appear slightly different than illustrated.
FOR VESA 100 MOUNTING PATTERN:
1) Choose hole pattern indicated below. 2) Attach tilt bracket (C) to back of screen using four M4 x 10 mm screws
(K) as indicated below. Tighten all security screws with security allen wrench (G).
Note: If installing LCD screen model Sharp
®
LC-13E1U, LC-15E1U, LC-20E1U, or if you don't get three complete turns in the screen inserts, use four M4 x 12 mm screws (L) instead of four M4 x 10 mm screws (K).
C
BOTT
OM OF SCREEN
Note: LCD screen may appear slightly different than illustrated.
10 of 12
ISSUED: 09-27-04 SHEET #: 100-9004-8 10-08-12
Installation of Screen in the Vertical Position
5
Insert two M5 x 12 mm screws (F) into column bracket of tube assembly (A) (see fi gure 5.1). Leave approximately
3/16" of thread exposed (see fi gure 5.2).
COLUMN
BRACKET
3/16"
EXPOSED
THREAD
F fi g. 5.1
fi g. 5.2
6
Hook tilt bracket (C) onto column bracket (see fi gure 6.1). Then secure with two M5 screws (F) (see fi gure 6.2).
Adjust tilt (20° forward and 5° back) and swivel to desired position. Tighten all screws using security allen wrench (G).
Note: Cable ties (Q) are provided for optional cord management along tube.
WARNING
• Always use an assistant or mechanical lifting equipment to safely lift and position the LCD screen.
fi g. 6.1
C
COLUMN
BRACKET
F
11 of 12 fi g. 6.2
ISSUED: 09-27-04 SHEET #: 100-9004-8 10-08-12
Installation of Screen in the Horizontal Position
5
Insert two M5 x 12 mm screws (F) into column bracket of tube assembly (A) (see fi gure 5.1). Leave approximately
3/16" of thread exposed (see fi gure 5.2).
COLUMN
BRACKET 3/16"
EXPOSED
THREAD
F fi g. 5.1
fi g. 5.2
6
Hook tilt bracket (C) onto column bracket (see fi gure 6.1). Secure with two M5 screws (F) (see fi gure 6.2). Adjust tilt (20° forward and 5° back) and swivel to desired position. Tighten all screws using security allen wrench (G).
Note: Cable ties (Q) are provided for optional cord management along tube.
WARNING
• Always use an assistant or mechanical lifting equipment to safely lift and position the LCD screen.
fi g. 6.1
C
COLUMN
BRACKET
F fi g. 6.2
12 of 12
ISSUED: 09-27-04 SHEET #: 100-9004-8 10-08-12
© 2012, Peerless Industries, Inc. All rights reserved.
All other brand and product names are trademarks or registered trademarks of their respective owners.

Download
Advertisement