BACnet/IP Servers to Profinet IO

BACnet/IP Servers to Profinet IO
Contact Us:
1-800-249-1612
Real Time Automation Gateways
460PSBC-N34
BACnet/IP Servers to Profinet IO
FEATURES
 Map Data Directly
from Profinet IO Slots
to Objects in your
BACnet/IP Servers
 BACnet/IP Supports
100 Read and 100
Write Scan Lines per
Device with up to 128
Objects per Scan line
 Support for up to 32
BACnet/IP Servers
 Map data from up to
10 Profinet IO Slots in
each direction
 Supports 1280 Bytes
of data in each
direction on Profinet
IO
 Effortless Browser
Based Configuration,
no programming
software is required
 Simple data
translation allows you
to manipulate data as
it passes between
protocols
Get Your BACnet/IP Server Devices Connected to a Profinet IO
Controller
The 460PSBC moves data between a network of up to 32 BACnet/IP
Servers and a Profinet IO Controller. With the 460PSBC you are making
a direct connection between Profinet IO data and your BACnet/IP
Servers.
How Do You Map the Data?
BACnet/IP Server data will be mapped into 10 Profinet IO Slots. Each
Slot will be assigned a typed of Int8, int16, int32, int64, Uint8, Uint16,
Uint32, Uint64, float, double, binary8, binary16, binary32, or Short
String. The Slot can consist of up to 128 bytes of data from your
BACnet/IP device that your Profinet IO Controller will view as Profinet
data. When writing from your Profinet IO Controller, Profinet IO data will
be presented to your BACnet/IP Servers as BACnet/IP data.
It’s really that simple. Need to modify your data as it passes from one protocol to the other?
No problem. Each data mapping you apply can be modified with up to 3 mathematic
functions. Add 4 to a value, multiply by 4 and divide by 10 with ease.
Why use Real Time Automation as a Gateway Supplier?
The 460PSBC provides an option to access BACnet/IP data on your Profinet IO Controller.
While there are certainly a number of other companies offering stand alone gateways, there
is no one who provides the level of support and service that you receive from RTA.
When you call a live person answers the phone. When you talk with sales you will get
honest answers and recommendations even if that means recommending someone else's
solution. When you get support it is from an engineer who had a hand in the product’s
development and support doesn't require a ticket or 24 hour wait. We are unashamed of
the fact that we are a smaller company because that means you mean a lot more to us.
Try the RTA difference today and give us a call at 1-800-249-1612 or check out more
information on us and our other solutions at www.rtaautomation.com.
A Word from our Founder
“It’s likely that your business isn’t industrial networking and it shouldn’t be. You make products, design systems, or
manage some process. Whatever it is that you make, monitor or install the process inevitably creates data. If
you’re a control engineer and your plant has been around for a few years your line is probably littered with devices
that send out all kinds of data over many different protocols. If you’re an automation device developer you probably
have customers that need to move your data into some other network. Either way, you’ve got a device conversion
problem. You have devices that generate ASCII , Modbus RTU, Modbus TCP, BACnet, Profinet, Profibus, Ethernet
TCP/IP , Ethernet/IP, DeviceNet or some other completely proprietary data and now you’re the person that has to
move that data to some other network! I feel your pain… and rather than just my sympathy, I have a solution for
you. You see, while your business may not be moving data around a factory floor mine is. In fact, it’s all that we
have done for over twenty years now. Our 460 series of Device Converters is the culmination of those twenty
years. You can now move all of your data, where you want, when you want and how you want. Try us on your next
project, I guarantee you wont regret it.”
John Rinaldi
Specifications
www.rtaautomation.com
BACnet/IP CLIENT FEATURES
BACnet/IP Operation Modes
BACnet/IP Client
Supported Object Types
Device, BI/BO/BV, AI/AO/AV, MI/MO/MV, Character String Value
Supported Service Codes
Maximum Connections
Read Property-A, Read Property Multiple-A, Write Property-A, Write Property Multiple-A, Device Dynamic BindingA
32
Number Read/Write Scan Lines per Device
200 Total - 100 reads & 100 writes
Scan Line Support
Up to 128 Objects
PROFINET IO SERVER FEATURES
Maximum Number of Slots
10 Slots in, 10 Slots out
Slot Size
8, 16, 32, 64 or 128 Bytes
Each Slot Can be Defined for a Single Data Type of
Int8, int16, int32, int64, UInt8, Uint16, Uint32, Uint64, float, double, binary8, binary16 or binary32, Short String
Total Data Supported in Each Direction
1280 Bytes
Maximum Profinet IO Controller Connections
1
INCLUDED WITH GATEWAY
120 volt AC wall wart power supply
Manual
6’ power cable with flying leads
5 year hardware warranty
IPSetup software — automatically locates RTA gateway on the network
Unlimited firmware feature upgrades for life
CAT5 crossover cable for direct connection to PC during programming
Complete, unlimited access to our industry leading support staff
DIMENSIONS
ELECTRICAL/ENVIRONMENTAL
DC Input Voltage
8 VDC @ 230 mA to 28 VDC @ 80 mA
Maximum Baud Rate
115K baud
Operating Temperature
Certification
-40 C to 85 C
RoHS-Compliant, UL, CUL, CE Approvals, Class I Div 2
ENCLOSURE / HARDWARE
Size
4.2” x 3.25” x 1”
Weight
5 oz.
Enclosure Type
Anodized aluminum
Mounting
Din rail or panel mount
LEDs
Ethernet link/data LED, Ethernet speed LED, power LED, &
2 general purpose LEDS on side
GATWAY FEATURES & FUNCTIONS
Gateway Security
You can configure up to 9 different users access to
diagnostic and configuration screens.
Alarming
Set <, <=, >=, >, ==, !=, and change-of-state rules on
any data moving through the gateway. If alarm rule is
triggered an email notification can be sent.
Translation Table
Allows for data manipulation during protocol translation. Scaling and other data format changes can occur
in the gateway.
Status and
Counters
Protocol specific status, counters and error messages
are accessible within the gateways diagnostics page.
They can also be delivered to a connected device.
Diagnostic Logging
Page
Allows users to see and log start up sequences, protocol specific messages & error messages.
NOT EXACTLY WHAT YOU WERE LOOKING FOR?
Real Time Automation offers a full line of gateway products. If this isn’t the one
you were looking for chances are we still have right solution for you. Give us a
call at 1-800-249-1612 or check out a listing at www.rtaautomation.com/products.
We also offer custom gateways to help customers dealing with unique needs or
proprietary protocols.
CATALOG #
DESCRIPTION
460PSBC-N34
BACnet/IP Server to Profinet IO Controller Gateway
Allen-Bradley, ControlLogix, CompactLogix, PLC-5 are registered trademarks of Rockwell Automation, Inc.
Real Time Automation, Inc. - www.rtaautomation.com - 1-800-249-1612
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertisement