SSH Console Serial Switch - Network Technologies Inc

SSH Console Serial Switch - Network Technologies Inc
User’s Guide
Digi Passport
90000767-88_A
© Digi International Inc. 2006. All rights reserved.
Digi, Digi International, the Digi logo, Digi Passport, the Making Device Networking Easy
logo, Digi One, and RealPort are trademarks or registered trademarks of Digi
International, Inc. in the United States and other countries worldwide. All other trademarks
are the property of their respective owners.
This product contains software licensed under the GNU Public License version 2 and
other open source licenses.
(http://www.gnu.org/copyleft/gpl.html
An SDK for all open-source code used in this product is available free of charge from Digi
International (send email to [email protected]) for more information.
Microsoft Windows Server 2003 is a trademark of Microsoft Corporation.
4
Contents
Chapter 1
Introduction
Digi Passport™ Model Support ............................................................................13
Feature Overview .................................................................................................13
Feature Summary.................................................................................................13
User Groups .........................................................................................................15
Root and Admin Usernames and Passwords.......................................................16
Adding Port Administrators and Users .................................................................16
Ways to Configure the Digi Passport ...................................................................16
Web Interface ............................................................................................... 16
Configuration Menu ...................................................................................... 17
Command Line Interface .............................................................................. 18
Ways of Accessing the Digi Passport Ports: Overview ........................................18
Web Interface Access Menu ................................................................................18
Port Access Menu. ...............................................................................................20
Direct Port Access................................................................................................20
Custom Menus .....................................................................................................21
Port Escape Menu................................................................................................21
Description of Fields ..................................................................................... 21
SNMP ...................................................................................................................22
Saving and Applying Changes .............................................................................22
One Step: Save and Apply Changes ............................................................ 22
Two-Step: Save to Flash and then Apply Changes ...................................... 22
Automatic Device Discovery Protocol ADDP .......................................................22
Automatic Device Recognition .............................................................................23
Locator Light.........................................................................................................23
Chapter 2
Getting Started
Introduction...........................................................................................................25
Assigning IP Settings from the Console Port .......................................................25
Configuring for SSH .............................................................................................26
Options ......................................................................................................... 26
Configuring the Port Access Menu for SSH ................................................. 26
Configuring a Port for SSH ........................................................................... 27
Windows Configuration for PPP ...........................................................................28
Windows XP ................................................................................................. 28
PPP configuration using a Linux client. ........................................................ 28
Passport ....................................................................................................... 28
Redhat 9 machine ........................................................................................ 29
Adding, Editing, and Removing Users..................................................................30
Procedure ..................................................................................................... 30
About Shell Options ...................................................................................... 31
Contents
5
Chapter 3
Installing and Configuring PC Cards
Introduction...........................................................................................................33
Compatible PC Cards...........................................................................................33
Adding a Compact-flash Card ..............................................................................33
Adding a Network Card ........................................................................................34
Adding a Wireless LAN Card................................................................................35
Adding a Serial Modem ........................................................................................36
Chapter 4
User Interface
Digi Passport User interface.................................................................................39
Administering Users .............................................................................................40
Required Privileges ...................................................................................... 40
Procedure ..................................................................................................... 40
To Add an Access List to the Digi Passport Unit .......................................... 42
Chapter 5
System Status and Port Logging
Introduction...........................................................................................................45
System Status & Log............................................................................................45
System Information ...................................................................................... 45
IP Information ............................................................................................... 46
Enabling Log Storage Location ............................................................................46
Enable NFS Server ...................................................................................... 46
Alert for NFS Server Disconnect .................................................................. 47
Enable Server ............................................................................................... 47
Enable a Compact-flash Card ...................................................................... 49
Enable the Passport Unit’s Memory ............................................................. 49
Configuring System Logging ................................................................................50
Viewing System Logs ................................................................................... 51
Configure Port Logging ........................................................................................51
Viewing Port Logs ........................................................................................ 52
Chapter 6
Configuring Ports
Introduction...........................................................................................................55
Enabling and Disabling the Ports .........................................................................55
RealPort Support..................................................................................................55
Resetting Ports.....................................................................................................57
Reset Individual Port Settings ...................................................................... 57
Port Title ...............................................................................................................57
Configuring Automatic Device Recognition ..........................................................57
Apply all Ports Settings ........................................................................................59
Host Mode Configuration......................................................................................59
Console Server Mode ................................................................................... 60
Terminal Server Mode .................................................................................. 60
Dial-In Modem Mode .................................................................................... 61
Dial-In Terminal Server ................................................................................ 61
Configuring Host Mode.........................................................................................62
Supported Protocols.............................................................................................63
Serial Port Parameters .........................................................................................64
DTR Behavior ............................................................................................... 64
Inter-character Timeout ................................................................................ 64
6
Contents
Specialty Use of Port -When Data is Processed in Chunks .................................65
Remote Ports .......................................................................................................66
Configure Remote Ports ............................................................................... 66
Accessing a remote port ............................................................................... 66
Chapter 7
Alerts and Notifications
Introduction...........................................................................................................69
Configuring SMTP Alerts......................................................................................70
SNMP Information ................................................................................................70
Traps ....................................................................................................................71
Configuring SNMP v1 or v2..................................................................................71
Managing the SNMP Protocol ..............................................................................72
Configuring Port Event Handling ..........................................................................76
Config Alerts for Automatic Device Recognition (ADR)........................................78
Chapter 8 Intelligent Platform
Management Interface
Introduction...........................................................................................................81
Procedure ..................................................................................................... 81
Chapter 9 User, Security, and Authentication
Configuration and Administration
Introduction...........................................................................................................89
Configuring User Access Control .........................................................................89
Configure User Access Privileges ................................................................ 91
Restrict a User’s Privileges .......................................................................... 91
Change the Privileges of an Access List ...................................................... 92
Sniff Session ................................................................................................ 93
Security Profile .....................................................................................................95
System Security ........................................................................................... 95
Password Security ........................................................................................ 96
Authentication.......................................................................................................96
Configuring Authentication Methods for Port Access ...........................................97
Configuring Authentication for the Web Server ....................................................98
LDAP Authentication .................................................................................... 98
Custom PAM Module ................................................................................... 99
Samba configuration> ..........................................................................................99
Samba server ............................................................................................... 99
Passport ....................................................................................................... 99
Chapter 10 Custom and Default Menus
Introduction.........................................................................................................101
Making Custom Menus.......................................................................................101
Adding Users .............................................................................................. 101
Creating Menu Names ............................................................................... 102
Adding Menu Items .................................................................................... 103
Assigning Users to a Menu ........................................................................ 104
Contents
7
Default Menu ......................................................................................................104
Port Access Menu ...................................................................................... 104
Chapter 11 Microsoft SAC Support
About the Digi Passport Unit’s Support for Microsoft Windows Server 2003 ....107
Setup Overview ..................................................................................................108
Setting Up the Windows Server 2003 Port.........................................................108
Command Syntax ....................................................................................... 108
Command Example .................................................................................... 108
Setting Up the Digi Passport Unit for SAC Support............................................108
Accessing the Windows Server 2003 Console Port from the Digi Passport Unit’s GUI
109
Chapter 12
Configuring FreeKVM
Introduction.........................................................................................................113
An Example Configuration .......................................................................... 113
Free Protocols ............................................................................................ 113
Using FreeKVM with Remote Desktop Protocol.................................................114
Configuring ................................................................................................. 114
Connecting to a system through FreeKVM using Remote Desktop Protocol 116
Using FreeKVM with VNC Protocol....................................................................116
Configuring ................................................................................................. 117
Connecting to a system through FreeKVM using VNC .............................. 118
Using FreeKVM with X Window System Protocol and XManager Software ......119
Configuring ................................................................................................. 119
Connecting to a system through FreeKVM using Xmanager ..................... 121
Web Redirection.................................................................................................122
Installing Programs for FreeKVM .......................................................................122
Remote Desktop Protocol .......................................................................... 122
VNC Viewer ................................................................................................ 123
Xmanager ................................................................................................... 123
Chapter 13 Rackable® Systems Management Card
Introduction.........................................................................................................125
Set up .................................................................................................................125
Setup of the Digi Passport Unit to Support the Rackable Systems Management
Card ............................................................................................................ 125
Configure Serial Port Communication Settings: ......................................... 125
Assign a Port Name: .................................................................................. 126
Accessing the Rackable Systems Management Card from the Digi Passport Unit’s
User Interface ............................................................................................ 126
Chapter 14 Configuring Remote Dial-In Access
Introduction.........................................................................................................129
Configuring for Dial-In Modem Access...............................................................129
Adding a PC Modem ..........................................................................................132
Configuring for Dial-In Terminal Server Access .................................................132
Chapter 15 Power Controller
Introduction.........................................................................................................135
8
Contents
Installing Power Controller .................................................................................136
Configuring Power Controller .............................................................................136
Configure the Serial Port Parameters to Match the Power Controller ........ 136
Add the Power Controller ........................................................................... 137
Serial Port info....................................................................................................137
Setting Alarms and Thresholds ..........................................................................138
Outlet Configuration ...........................................................................................139
User Access for Power Controller ......................................................................140
Configuring to Allow Specific Users Access ............................................... 140
Configuring to Restrict Specific Users ........................................................ 141
Power Controller Management...........................................................................142
Cascading Multiple Digi RPM Units....................................................................144
Chapter 16 Port Clustering
Introduction.........................................................................................................147
Configuring Port Clustering ................................................................................148
Assigning Master Clustering Mode ............................................................. 148
Configure Slaves to Join a Cluster ............................................................. 148
Advanced Clustering Configuration ............................................................ 149
Peer to Peer Clustering .............................................................................. 152
Accessing the Cluster Ports ....................................................................... 152
Clustering Peer-to-peer ......................................................................................152
Making up a peer_to_peer group ......................................................................154
Peer to peer mode configuration ................................................................ 154
Peer to peer information ............................................................................. 154
Join ............................................................................................................. 155
Invite peers ................................................................................................. 157
Withdraw .................................................................................................... 159
Remove ...................................................................................................... 159
Update ........................................................................................................ 159
Connecting to peers ...........................................................................................159
Link to web interface .................................................................................. 159
Link to port access menu ........................................................................... 159
Serial port connection page ........................................................................ 160
Connect to a port via connect.asp .............................................................. 160
Connect to a port via ssh ............................................................................ 161
Custom menu ............................................................................................. 161
Chapter 17 System Administration
Introduction.........................................................................................................163
Upgrading the Firmware.....................................................................................163
Web Interface ............................................................................................. 163
Configuration Management ................................................................................164
Automatically Saving the Configuration ...................................................... 164
Automatically Upgrading the Digi Passport Unit’s Firmware or Configuration using
TFTP ..................................................................................................................165
DHCP ......................................................................................................... 166
Contents
9
Directly Configure the TFTP Server and the Name of the “hash” File ........ 166
The Structure of the Hash File ................................................................... 166
Resetting Factory Defaults .................................................................................168
Setting Date and Time........................................................................................169
Configuring a Host Name ...................................................................................170
Chapter 18 Command Line Interface
Introduction.........................................................................................................171
Linux Commands ...............................................................................................171
Important File Locations .....................................................................................172
Default Script .............................................................................................. 172
Booting Sequence ...................................................................................... 172
Config Files ................................................................................................ 173
User Storage Space ................................................................................... 175
Example Scripts .................................................................................................175
User Administration ............................................................................................177
Locator LED Script ..................................................................................... 178
Chapter 19 Configuration Menu
Introduction to the Configuration Menu ..............................................................179
Accessing the Configuration Menu.....................................................................179
Configuring SSH.................................................................................................180
Adding, Editing, and Removing Users................................................................181
Adding and Configuring a PC Card ....................................................................181
Host Mode Configuration....................................................................................181
Port Parameters .................................................................................................182
Port Access Menu ..............................................................................................182
System Logging..................................................................................................183
Configure the System Log Device .............................................................. 183
Procedure for an NFS or SYSLOG Server ................................................ 184
Configure System Logging ......................................................................... 184
Configuring SNMP..............................................................................................185
Configuring SMTP ..............................................................................................185
Configuring Network IP Filtering.........................................................................185
Network IP Filtering ............................................................................................189
Port IP Filtering...................................................................................................189
Sniff Sessions.....................................................................................................190
Viewing A Sniff Session ............................................................................. 191
Field Descriptions for Sniff Sessions .......................................................... 192
Authentication.....................................................................................................193
Upload Server Certificate ...................................................................................194
OpenSSL (SSLeay) Simple CA Usage - Install Openssl ............................ 194
Make Root CA (Certificate Authority for Self-signed) ................................. 195
Making a Certificate Request ..................................................................... 196
Signing a Certificate Request ..................................................................... 197
Make Certificate for the Digi Passport Unit ................................................ 198
Dial-in Modem Access........................................................................................198
Dial-in Terminal Server Access ..........................................................................199
Clustering ...........................................................................................................200
Firmware Upgrade..............................................................................................201
10
Contents
Restoring Factory Defaults.................................................................................202
Setting Date and Time........................................................................................202
Accessing the Boot Loader Program..................................................................202
Hardware Test Menu .................................................................................. 203
Disaster Recovery ...................................................................................... 203
Chapter 20 Hardware Information
Introduction.........................................................................................................205
Hardware Specifications.....................................................................................205
Digi Passport 48 ......................................................................................... 205
Digi Passport 16 and Digi Passport 32 ...................................................... 206
Digi Passport 8 AC Powered ...................................................................... 206
LED Indicators....................................................................................................207
About Serial Port Cabling ...................................................................................207
Serial Port Pinouts..............................................................................................207
Cable Adapters...................................................................................................208
DB-25 Male Console Adapter ..................................................................... 208
DB-9 Female Console Adapter .................................................................. 209
DB-25 Female Console Adapter ................................................................ 210
DB-25 Female to RJ-45 Pin Assignments .................................................. 210
DB-25 Male Modem Adapter (Digi 8-pack reorder P/N 76000670) ............ 211
DB-25 Male Modem to RJ-45 Pin Assignment ........................................... 211
DB-9 Male Modem Adapter (Digi 8-pack reorder P/N 76000702) .............. 212
DB-9 Male Modem to RJ-45 Pin Assignment ............................................. 212
Ethernet Pinouts.................................................................................................212
Rack Mounting Installation .................................................................................213
Rack Mounting Safety Precautions ............................................................ 213
Chapter 21 Certifications
Safety .................................................................................................................215
Working Inside the Digi Passport Unit ........................................................ 215
Replacing the Battery ................................................................................. 215
Rack Mounting Installation Considerations ................................................ 215
Environmental Considerations and Cautions ............................................. 216
Safety Instructions ...................................................................................... 216
Emissions ...........................................................................................................217
Immunity.............................................................................................................217
Solaris Ready .....................................................................................................217
Contents
11
Introduction
Chapter 1
Introduction
Digi Passport™ Model Support
This manual offers information on the Digi Passport 4-port, 8-port, 16-port,
32-port, and 48-port models.
Feature Overview
With the Digi Passport unit, administrators can securely monitor and control
servers, routers, switches, and other network devices from anywhere on the
corporate TCP/IP network, over the Internet, or through dial-up modem
connections even when the server is unavailable through the network.
The Digi Passport employs SSHv2 encryption to keep server access
passwords safe from hackers, and supports all popular SSH clients, as well as
secure access from any Java-enabled browser. It is the first console server to
provide a secure graphical user interface for easy out-of-band management of
Microsoft Windows Server 2003 systems. It connects to serial console ports
using standard CAT5 cables eliminating the hassles of custom cabling. In
addition, the Digi Passport unit offers a PC-Card slot for adding dialup
modems, Ethernet, or wireless network cards. USB or PC-Card Flash devices
can be used to save port logs and back up configurations.
The Digi Passport unit is available in 4-, 8-, 16-, 32- and 48-port models, in a
1U rack-mount form factor.
Feature Summary
Category
Security
Authentication
Feature
•
•
•
•
SSH v2 server and client
TLS/SSL
IP Filtering
Central access to security parameters via
the Security Profile including network,
port, and password securities.
•
•
•
•
TACACS+
RADIUS
LDAP and Active Directory
Kerberos support for customized PAM
Modules
User access per port
Local user database
•
•
Chapter 1
13
Feature Summary
Category
Feature
•
•
•
•
•
•
•
•
Command line
WEB --HTTP/HTTPS
SNMPv3
IPMI 2.0
Custom applications
Port Triggers and Alerts
Multi level menus
Advanced Device Discovery Protocol
(ADDP) for locating the device on the
network
•
RemotePortsTM extends console
management features to remote devices
Integrated power management and control
in conjunction with Digi RPM power strips
Automatic Device Recognition
Perl programming and scripting
IP v4/v6 dual stack
Management
•
•
•
•
Data Capture
Port Access
freeKVMtm access
Expandable Capabilities
•
•
Local port logging
External logging (syslog, NFS, PC card,
USB Flash)
•
•
•
•
•
•
•
•
Telnet/SSH
Direct SSH and Telnet to individual ports
HTTP/HTTPS
Multiple concurrent users per port
Independent IP addresses per port
Raw TCP
Port escape menu
USB Export option
•
•
•
•
•
•
Windows Remote Desktop
VNC
Xmanager (X Window System)
Web Redirection
Radmin
User defined
CompactFlash/PC Card:
• Flash memory card
• Wireless LAN adapter (802.11b)
• Ethernet LAN adapter
• PSTN/CDMA modem card
USB:
• Expandable storage to USB flash
14
Chapter 1
Introduction
Category
Feature
•
•
•
•
•
•
•
•
Other Features
•
•
•
•
RealPort® and Encrypted RealPort
support
Solaris Ready
Multiple concurrent users per port
RemotePortsTM
Access lists per port
Flash upgradeable
SSH sessions simultaneously on all ports
Secure Clustering - Single IP for multiple
Digi Passport devices
Individual IP addresses per port
Automatable TFTP firmware and
configuration update upon boot
RSA SecurID® support using RADIUS
Find Me locator light
User Groups
The Digi Passport unit comes with 4 built-in user groups pre-defined by roles
or access levels. The following table lists the 4 user groups, their access
rights, and default user names.
Group
Access Privileges
Configuration
Privileges
Defaults
-----------
Ports
Command
Line
Ports
System
Login
Root
yes
yes
yes
yes
root
dbps
System Admin
yes
yes
(read only)
yes
yes
admin
admin
Port Admin
yes
no
yes
no
-
-
User
yes
no
no
no
-
-
Password
Access Lists
The Digi Passport unit supports access lists for user privileges. These lists can
contain multiple users and define specific port rights. If you have multiple
people responsible for the Sun Servers in your company and you want to give
them identical access rights you can create a "Sun-admin" access list, which
grants access to all the ports connected to Sun servers. You can then make all
the Sun administrators members of this access list. See "Create an Access
list" on page 70 for more information.
Chapter 1
15
Root and Admin Usernames and Passwords
Root and Admin Usernames and Passwords
The Digi Passport unit comes with two default users; root and system admin.
The user names of the the Digi Passport unit are case sensitive.
User Name
Default Password
root
dbps
admin
admin
Adding Port Administrators and Users
The system administrator and root user can add port administrators and
additional users easily with the web interface by choosing System
administration > User administration > Add user. The admin user's password
can be changed by either admin or root from within the Web interface or the
Menu CLI, the root user's password must be modified from the command line
using the command passwd.
Ways to Configure the Digi Passport
This section discusses the three ways to configure the Digi Passport unit using
the web interface, configuration menu, or command line interface.
Web Interface
The Digi Passport
web interface features
HTTPS for secure
access.
16
The web interface provides an easy way to configure the Digi Passport unit.
The root user and system administrator can configure all features through the
web. Port administrators can configure ports, including port clustering, but
cannot modify system settings. Only users with port or system administrative
rights can use the web interface for configuration.
There are two ways to access the web interface.
• ADDP (Advanced Device Discovery Protocol)
This device discovery tool allows you to find, configure and launch your
web configuration and management interface. ADDP will work whether or
not the unit has an address assigned, and whether or not there is a DHCP
server on the network, it only requires that the ADDP software is running
on a computer on the same LAN segment as the Digi Passport. Find your
device and double click it to access the web interface, or select your device
and click Configure network settings (on the left navigation bar).
• Directly entering the IP address
You can enter the IP address or hostname directly into the URL address
bar of your browser. (Of course, the IP address and DNS server if
hostname is used, must already be set up)
Access the web interface from one of the previous methods. The following
page is displayed after login.
Chapter 1
Introduction
Configuration Menu
The root user and system administrator have full access to the configuration
menu from a Telnet or SSH session or a serial connection through the console
port. Functionality is similar to the web interface, with the exception of custom
menus, which can be created only from the web interface. The configuration
menu is presented by entering the command configmenu.
Chapter 1
17
Ways of Accessing the Digi Passport Ports: Overview
Command Line Interface
The command line interface can be accessed from a Telnet or SSH session or
from the console port. The root user always has access to this interface. The
admin user can be granted read-only permission as well.
Ways of Accessing the Digi Passport Ports: Overview
There are multiple ways to access the native serial ports on the Digi Passport
unit:
• Web Interface
• Port Access Menu
• Direct Port Access
• Custom Menus
Web Interface Access Menu
The web interface menu provides easy and convenient access to ports. All
users can access the menu by entering the the Digi Passport unit IP address
or host name in a web browser’s URL window. You will only be able to see the
ports that you are allowed to access.
To access a port from the web interface, do the following:
1. Access the web interface.
2. Click Serial port > Connection.
3. Select a port.
A Java applet or Telnet window opens with a login prompt.
18
Chapter 1
Introduction
The web interface can also be configured to call a local Telnet or SSH
application, see "Configuring Host Mode" on page 62.
Chapter 1
19
Port Access Menu.
Port Access Menu.
Access
Type
Permissions
Web interface
Any user can use this method.
Telnet/SSH
Any user can use this method.
Command
line
Procedure
1. Access the web interface
2. Choose Serial port > Connection > Port access
menu connection
3. Log in
1. Telnet to the Digi Passport unit specifying its IP
address and port 7000. (7000 is the default
socket port for Telnet) Example:
telnet 192.168.15.7 7000
2. Log in
From the command line, issue the
portaccessmenu or connect command. Example:
portaccessmenu
Root
connect 4
to connect to port 4
Example: telnet passportdemo.digi.com
Telnet/SSH
Any user
If user’s shell is configured to "Port access
menu", please refer to "Administering Users" on
page 69.
The Port Access Menu provides access to ports. It is accessible to all users
through the web interface, Telnet and SSH sessions, and remote modem
access.
Direct Port Access
Connect directly to a properly configured port through a Telnet or SSH
session. Configuration requirements include setting the Host Mode to Console
Server Mode and the Protocol to either Telnet or SSH. Ports, by default are set
to Console Server Mode and Telnet. Use the following information to make a
Telnet or SSH connection to a port:
Type
20
Command Syntax
Example: Connection to Port 3
Telnet
telnet ip-address tcp-port
where ip-address is the Digi Passport unit’s
IP address and tcp-port is the Listening TCP
port for a port
telnet 192.168.15.7 7003
(7000 is the default socket port for both
Telnet and SSH)
SSH
ssh [email protected] ip-address tcp-port
where user-name is a user’s name,
ip-address is the Digi Passport unit’s IP
address and tcp-port is the Listening TCP
port for a port
ssh user-name:”p=port-number”@ip-address
or
ssh user-name:”t=port-title”@ip-address
ssh [email protected] 192.168.15.7 -p 7003
(7000 is the default socket port for both
Telnet and SSH)
ssh sunadmin:”p=25”@Digi12
ssh ciscoadmin:”t=Cisco-main”@Digi12
Chapter 1
Introduction
Type
WEB
Command Syntax
http://ip-address/connect.asp?t=port-title
http://ip-address/connect.asp?p=portnumber
where ip-address is the Digi Passport unit
IP address or DNS name, port-number is the
number of the serial port and port title is the
name of the port as assigned in serial port,
port title.
Note:
Example: Connection to Port 3
http://passportdemo.digi.com
connect.asp?t=CISCO.Router.port3
(the port name is case sensitive)
The example assumes that the Listening TCP port is 7003, the default for port 3.
Custom Menus
Custom menus are created by either root or the system administrator to limit
your access to specific ports. For more information, see "Making Custom
Menus" on page 101.
Port Escape Menu
Port escape is the ability to escape from a port without disconnecting. Port
escape is available in main sessions as well as sniff sessions. Every
connection method accommodates port escape. You configure the escape
sequence per port. Follow the procedure to configure the port escape
sequence.
1. Serial Port > Configuration > Select the port number or All.
2. Host mode configuration > Port escape sequence - enter a letter for the Port
escape sequence. The default is <ctrl> z.
3. Click Save to flash and continue with other configurations or click Save & apply
for the changes to take effect.
4. Click Save & Apply.
The port escape menu is automatically started if there is one active session to
the port established.
5. Enter the port escape sequence. (^z)
The following table describes the fields and the operations for the port escape
feature. You will only see the fields allowed for your permissions.
Description of Fields
Escape
Sequence
Ctrl+
Chapter 1
Description of Action
Occurrence
b
send break
not functional for sniff users
l
show last 100 lines of log buffer
must enable logging for this option
d
disconnect a sniff session
only functional to admin
a
send message to port user(s)
not available to sniff users
21
SNMP
Escape
Sequence
Ctrl+
Description of Action
Occurrence
r
reboot device using power-switch
only if power management is
available on this port
p
power device on/off
(show only on or off) only if power
management is available on this port
x
close current connection to port
closes the current sniff session
Note:
By entering the port escape sequence twice, it is directly transmitted (once) to the
connected device. If the escape sequence is entered twice within 1/2 second, the
menu will not open.
SNMP
An SNMP MIB to configure the Digi Passport unit is available on the Passport
CD and can be downloaded from support.digi.com.
Note:
SNMP configuration needs to be enabled in the security profile to allow use of this
MIB. This is accomplished under the System Administration->Security Profile section of the configuration screen. See "Security Profile" on page 95 for more information
Saving and Applying Changes
In the web interface, you can save and apply configuration changes in two
ways. With the one-step method, you choose “Save & apply” and changes are
saved and applied (take effect) immediately. With the two-step method, you
choose “Save to flash,” which immediately saves changes but the changes do
not take effect until you choose Apply changes. The following topics describe
how to do each of these operations.
One Step: Save and Apply Changes
To save and apply changes immediately, choose the Save & apply button.
Two-Step: Save to Flash and then Apply Changes
To save multiple changes but apply changes once, do the following:
Choose the Save to flash button.
When you finish changing the configuration, choose the Apply changes link,
which is located on the left navigation menu (or the Save & apply button at the
bottom of the page.)
Automatic Device Discovery Protocol ADDP
See the quick start guide that came with the device to set up the configuration.
Or insert the CD and select the Device Discovery wizard. Select and click the
correct device to configure.
The Device discovery wizard knows the default password for the device. It will
prompt you for the password for the root user if you have changed it from the
default (dbps)
Configure the IP.
Once the Digi Passport is configured with a valid IP address, you can login to
the webUI with username admin, password admin.
22
Chapter 1
Introduction
Automatic Device Recognition
This feature allows the Digi Passport unit to automatically detect and
recognize attached devices. The Digi Passport unit sends down a probe string,
default is < Enter > then analyzes the response. If "Use detected port title" is
enabled, it will display the detected OS, device and port number in the format:
CISCO.Router.port3
Sun.nemo.port5
To enable Automatic Device Recognition:
1. Serial Port > Configuration > Select the port number or All.
2. Port title
Automatic Detection - Enable
Use detected port title - Enable
Probe String - \x0D (means <Enter>)
Device detection method - Active
Detection initiation - periodically
Detection delay - every 5 minutes
3. Click Save & apply.
Automatic Device Recognition also monitors each of the configured serial
ports. This allows you to receive an e-mail or SNMP trap if there is a change in
the expected response from the device connected to the serial port. If the
device goes down or is disconnected for any reason, you are notified.
For configuration of this alarm feature please refer to Configuring Ports
Chapter 6.
Locator Light
The Digi Passport unit has two locator lights, one on each side of the unit.
Log into the WebUI as admin or root and Click Start device locating and a
popup box will appear to confirm. Click okay and the Digi Passport unit Find
me light will blink.
To turn off the Find me light, click Stop device locating.
Chapter 1
23
Locator Light
24
Chapter 1
Getting Started
Getting Started
Chapter 2
Introduction
This chapter covers basic configuration topics. Included is information on
assigning IP settings, enabling secure access with the web interface,
accessing the unit through SSH, and adding or removing users.
Note:
Initial setup is described in the Quick Start Guide included with the product
packaging.
Assigning IP Settings from the Console Port
The following steps use the console port to assign IP settings to Ethernet
port #1.
The default IP
address is
1. Connect the console port on the rear panel of the Digi Passport unit to a
192.168.161.5.
serial port on a workstation using the supplied straight-through CAT5 cable
and the appropriate console adapter packaged with the the Digi Passport
unit.
2. Configure a terminal emulation program, such as HyperTerminal, using the
following settings:
• bps=9600
• data bits=8
• parity=none
• stop bits=1
• flow control=none.
3. Establish a connection to the console port and press Enter to get a
command prompt.
Chapter 2
25
Configuring for SSH
4. At the login prompt, log in as admin. The default password for admin is
admin.
The Configuration menu appears.
5. Enter the number 1 for Network Configuration.
6. Enter the number 1 to select the port for IP configuration
7. Enter 1 for IPv4.
8. Enter the appropriate parameters for the IP settings.
9. Press ESC when done to return to the main configuration menu.
10. Enter the number to exit and apply changes.
Changes are saved and applied immediately. There is no need to reboot.
Configuring for SSH
Accessing the Digi Passport unit's command line via SSH is enabled by
default (TCP port 22).
Options
The Port Access Menu and individual ports can be configured for SSH.
The the Digi
Passport unit
supports Blowfish
and 3DES
encryption
methods for SSH.
26
Configuring the Port Access Menu for SSH
1. Access the web interface.
2. Log in as root, admin, or a member of the port administration group. The
default password for root is dbps, and the default password for admin is
admin.
3. Under Serial port > Configuration > Port access menu configuration.
The Port access configuration menu appears.
4. Select SSH as the Port access menu protocol.
Chapter 2
Getting Started
Note:
The "Log in on port access" feature requires the user to log in twice (once for
access to the port access menu and again for the specific port) when enabled. If
this feature is disabled the only login challenge is to the Port Access Menu
(though only permitted users will be able to successfully connect to any specific
port).
5. Click Save & apply.
Configuring a Port for SSH
1. Access the web interface.
2. Log in as root, admin, or a member of the port administration group. The
default password for root is dbps, and the default password for admin is
admin.
3. Under Serial port > Configuration.
4. Select All or one individual port you want to configure for SSH.
5. Click Host mode configuration.
6. Specify SSH as the Protocol as shown in the following screenshot.
7. Click Save & apply. see following screenshot.
Chapter 2
27
Windows Configuration for PPP
Windows Configuration for PPP
Windows XP
1. Open "Network Connections" window [Start->Control Panel->Network Connections]
2. Start New connection Wizard [File->New connection] on "Network
Connections" window
3. Select "Connect to the network at my workplace" and press Next button
4. Select "Dial-up connection" and press Next button
5. Select "Dial-up connection" and press Next button
6. Enter Connection name and press Next button
7. Enter Phone number and press Next button
8. Select either "Anyone" or "My use only" for Connection Availability and press Next button
9. Click Finish button
10. . Open properties window by clicking right mouse button on the Connection just you made
11. On Security tab, check "Advanced" for Security options and press "Settings" button
12. Set each parameters on Advanced Security Settings window as follows,
. Data encryption: Optional encryption (connect even if no encryption)
Allow these protocols: Unencrypted password(PAP)/Challenge Handshake Authentication
Protocol(CHAP)
And then press OK button
13 Check "Run script" check box, select "Generic login" and then press Edit button
14 Edit following lines of switch.inf file
line 72: OK=<match>"ogin:" => OK=<match>"ogin:"; insert a space character before
":"
line 80: COMMAND=<user name><cr> => COMMAND=admin<cr>
line 89: OK=<match>"assword:" => OK=<match>"password" ; insert a space character before
":"
line 97: COMMAND=<password><cr> => COMMAND=admin<cr>
and then save file.(Attached please find my switch.inf file for your reference)
15 Press "OK" button on Properties window
16 Double click Connect icon on Dial-up connection.
And enter User name and Password, and then press dial button.
PPP configuration using a Linux client.
Passport
1. [Network -> PPP configuration->Basic PPP settings]
Dynamic IP address pool for incoming connections: Enable
First IP address: enter the starting address of IP pool (192.168.161.200)
28
Chapter 2
Getting Started
Number of address: enter the number you want, say (10)
Press "save to flash" button
2. [Network -> PPP configuration->incoming PPP connection]
Add user for PPP connection and set each parameters
Authentication configuration
Username: admin
Password (new): admin
Password (confirm): admin
Authentication: CHAP/PAP
Peer configuration
(*) Automatically assign remote IP address from IP address pool
(v) Allow client access to local network via PPP connection
(*) Automatically assign local IP address from IP address pool
Press "save to flash" button
Please specify the Password after setting all other parameters.(just before
pressing "save to flash" button)
If not, Null Password can be specified while changing other parameters.(We
will fix this problem in rc version)
[Peripherals->Modem configuration] (v) Enable PPP connection on the
Modem
Press "save & apply" button
Redhat 9 machine
1. 1. run kppp
# kppp
2.
3.
4.
5.
6.
7.
8.
9.
Chapter 2
Press "Setup" button on KPPP window
Press "New" button on Accounts Tab on KPPP Configuration window
Select "Dialog Setup" on Create New Account window
Enter any name you want in Connection name field on Dial tab on New
Account window6. Press "Add" button on Dial tab on New Account window
Enter phone number of internal modem and press "OK" button
Select authentication as "PAP/CHAP" on Dial tab on New Account window
Select Dynamic IP address on IP tab on New Account window
Select Default gateway on Gateway tab on New Account window
29
Adding, Editing, and Removing Users
10. Select Automatic configuration on DNS tab on New Account window
11. Add following Login Scripts sequentially on Login Script tab on New
Account window
Expect Login:
Send admin
Expect Password:
Send admin
Please note that there is a space character before ":" character in Expect case
And then press "OK" button
12. Select Device tab on KPPP Configuration window and check each
parameters
You may use default values except Modem device.
Please select the device that modem is connected
Then press "OK" button
13. Select Connection name that you just configured on KPPP window
And enter Login ID and Password and check Show log window checkbox
14. Finally Press "Connect" button and you can see the login process on Login
Script Debug Window
If there is any error, you can find the reason on Redhat machine by checking /
var/log/messages file
After connection, please check whether there are correct PPP interfaces in
Passport and Redhat machine both.
Current Passport firmware you have has a problem in using PC modem card,
we will fix this problem in rc version.
PPP mode in serial port can be set in [Serial port configuration ->Host mode
configuration->Host mode]
Adding, Editing, and Removing Users
The root user and system administrator can add, remove, or edit users from
the web interface.
Procedure
1. Access the web interface.
2. Log in as root or admin. The default password for root is dbps, and the
default password for admin is admin.
30
Chapter 2
Getting Started
3. Under the System administration heading click Users administration.
4. Select Add, Edit, Remove or click the username to edit a user.
• Add: Assign a user name, user group, password, and shell.
• Edit: Change user group, password, or their shell
• Remove: Remove a user from the system
5. Click Save & apply.
Note:
The root and admin users cannot be removed from the system.
For more information about configuring access rights for specific users see
"Configure User Access Privileges" on page 91.
About Shell Options
The shell program selection determines the interface you see when
establishing a Telnet or SSH session or connecting via the console port with
the Digi Passport unit.
User Group
Chapter 2
Shell Program Options
root
command line
system admin
command line, configuration menu, port access menu, custom
menus
port admin
configuration menu, port access menu, custom menus
31
Adding, Editing, and Removing Users
User Group
user
32
Shell Program Options
port access menu, custom menus
Chapter 2
Installing and Configuring PC Cards
Chapter 3
Installing and Configuring PC Cards
Introduction
This chapter includes information on adding and configuring PC cards for the
Digi Passport 8, 16, 32, and 48 port units. PC card devices that can be added
to the the Digi Passport unit include a serial modem, compact-flash card,
wireless LAN card, and a network LAN card.
Compatible PC Cards
All compact-flash, and most simple serial modem cards should work with the
Digi Passport, but not all LAN, wireless LAN, or combo cards will. To see a list
of compatible cards that have been tested with the Digi Passport unit, visit the
Digi support site at http://www.digi.com/passport/.
Adding a Compact-flash Card
A PC card slot is located on the front panel of the Digi Passport unit. The
arrow in the following graphic indicates the PC card slot.
PC card slot
Digi Passport 32 shown
To install and configure the compact-flash card on the Digi Passport unit, do the
following.
1. Insert the card into the PC card slot.
2. Access the web interface.
3. Under the PC card heading click Configuration.
Always select the
Stop card
service button
and Save & apply
before removing
the PC card.
Chapter 3
4. Click Configure the detected card.
The following fields appear on the configuration page.
— ATA/IDE Fixed Disk Card configuration
Total data size to be used - Enter the amount of memory you want to assign to
the compact-flash card for configuration files.
Delete all files in ATA/IDE Fixed Disk Card - Select the Delete button to clear the
33
Adding a Network Card
compact-flash card of all files.
Format ATA/IDE Fixed Disk Card. -
The options are EXT2 or FAT formats. If it
is necessary to format the card, select the format option and then select the
Format button.
5. Enter the appropriate parameters on the configuration page.
6. Click Save to flash or Save & apply.
Adding a Network Card
To install and configure a network card on the Digi Passport unit, do the
following.
1. Insert the card into the PC slot.
2. Access the web interface.
3. Under the PC card heading, click Configuration.
34
Chapter 3
Installing and Configuring PC Cards
Note:
The card is automatically discovered and a configuration menu is displayed.
4. Enter the appropriate parameters in the configuration menu.
5. Click Save & apply.
Note:
If DHCP is active the IP address will appear after "Save & apply" is clicked.
Adding a Wireless LAN Card
To install and configure a wireless LAN card on the Digi Passport unit, do the
following.
1. Insert the card into the PC slot.
2. Access the web interface.
3. Under the PC card heading, click Configuration.
Note:
The card is automatically discovered and a configuration menu is displayed.
4. Click Configure the detected card.
5. Enter the appropriate parameters in the configuration menu.
WEP is the acronym for Wired Equivalent Privacy and is a security protocol
for wireless LANs using encryption to protect data transfers. If you are
unsure of the settings for the wireless card, see your network administrator.
SSID - Set Service Identifier and is the name of the wireless LAN network
Use WEP key - Enable or disable the WEP key
WEP mode - Encrypted or unencrypted
WEP key length - The options are 40 or 128 bits if the WEP key is enabled
WEP key string - Refer to the wireless network administrator for the
wireless encryption key string
Chapter 3
35
Adding a Serial Modem
6. Click Save to flash.
Adding a Serial Modem
The modem must first be inserted and installed on your system before it can
be used. To configure the modem do the following:
1. Access the web interface.
2. From the menu click Configuration under the PC card heading.
Note:
The card is automatically discovered and a configuration menu is displayed.
3. Click Configure the detected card.
36
Chapter 3
Installing and Configuring PC Cards
4. Edit any appropriate parameters and Click Save & apply.
Chapter 3
37
Adding a Serial Modem
38
Chapter 3
User Interface
Chapter 4
User Interface
Digi Passport User interface
While the Digi Passport provides many capabilities for the Passport
Administrator, the goal is to make the experience as simple as possible for the
Passport User (who has other systems to worry about).
Upon login, the Passport user is presented with a page that shows the
systems that they are allowed to manage or control.
The only option available under System Administration is to change their own
password.They can also log in as a different user or log out of the system.
The Passport Connection page provides an iconic representation of the status
of the equipment under management when you click a specific port:
Chapter 4
39
Administering Users
If the power to a unit is turned off, then the power warning status is indicated
on the main screen.
If an event alert has been triggered, then the Alert Icon will appear.
Clicking on the System name or port number will expand the view so that all
available methods of connection or management are specified. Systems can
be powered on and off, a console to the serial console can be launched, and a
freeKVM session can be initiated to the server. The port log can also be
reviewed to see what event triggered the alarm.
Administering Users
Required Privileges
Only root and admin can administer users. The root user has unlimited
administration privileges. Admin can view and change all attributes except
those that belong to the root user.
There are several ways to manage users. A user can be added, edited, or
removed. Multiple users can be managed in Groups or Access lists. The
difference between Groups and Access lists are that Groups define privilege
levels to access or change configuration of the Passport unit itself (for
Passport unit administration) while Access lists define rules for access to ports
and port capabilities.
Access Lists manage rights of multiple users at the same time. Multiple users
with the same rights are associated with an access list. This allows the
administrator to simplify the overall administrative process.
Procedure
1. Access the web interface.
2. Under System administration, choose User administration.
The following screen appears.
40
Chapter 4
User Interface
Note:
Usernames on the Digi Passport unit are case sensitive.
3. Do one of the following:
To...
Chapter 4
Do the Following...
Add a user
1. Click Add.
2. Fill in the attribute fields. See the table that follows for
information on attribute fields.
3. Click Add.
Edit a user
1. Click on the username.
2. Fill in the attribute fields. See the table that follows for
information on attribute fields.
3. Click Submit.
Remove a user
1. Check the box that corresponds to the user you want to
remove.
2. Click Remove.
3. Choose OK at the prompt.
41
Administering Users
To...
Create an Access
list
Do the Following...
1. Under System administration, click Access List.
2. Enter the name of the Access List and click Add.
3. Click on the access list name to add users
4. Add the users to the access list
Note: The name field in the Access list allows you to
add users that are not locally configured on the
Digi Passport unit but use a centralized authentication method like RADIUS, LDAP etc.
To change the privileges of an Access list, see "Change the
Privileges of an Access List" on page 92
4. Click Apply changes.
To Add an Access List to the Digi Passport Unit
1. Access the web interface of the Digi Passport unit.
2. Under System Configuration choose Access Lists
3. Enter the access list name into the edit-box and click [ADD].
A pop-up windows will appear confirming the successful addition of an access
list. Now you can add users to the access list by:
1. Click the name of the access list; a configuration windows will open
2. Add one user at a time to the list by:
Entering the name into the edit-box and clicking on [ADD].
Note:
42
Caution! Spelling is not verified against the local user database. This allows you
to add externally configured users that only exist in the RADIUS, LDAP or other
central databases.
Chapter 4
User Interface
After an access list has been added to the system, port rights can be
associated with it. See chapter 8.
User Fields
Field
Chapter 4
Description
User name
Name for the user, which must be between 3 and 29
characters and cannot include colons (:), less than or greater
than signs (< >), ampersand (&), spaces, or quotation marks.
The at sign @ and period. are acceptable.
The username on the Digi Passport unit is case sensitive.
Select group
Group to which the user is assigned. Groups include Root,
System Admin, Port Admin and User. See "User Groups" on
page 15 for more information
Password
Password to assign to the user.
Confirm password
Confirms the password.
Shell program
Interface presented to the user when he/she logs on to the
system from a Telnet or SSH connection.
SSH public key
authentication
Alternative method of identifying yourself to a login server.
More secure than just a password.
SSH public key to
use
Current public file key or create a new public file key
Select new SSH
public key version
SSH1 only supports one type of key
SSH2 supports both RSA and DSA key types
Select new SSH
public key file
Location for the SSH public key file
43
Administering Users
44
Chapter 4
System Status and Port Logging
System Status and Port Logging
Chapter 4
Introduction
The Passport unit provides four options for saving system and port logs:
• A syslog server
• An NFS server
• Removable flash storage (PC-card or USB)
• The Passport unit’s memory.
When memory is selected as the storage location, log files are saved to
volatile memory, meaning files are lost when the power is turned off. To use a
syslog server, an NFS server, or flash, you must first enable the devices and/or
enter the required information before you can designate them as storage
locations.
System logs track events such as logins, authentication failures, system
configuration changes, and more. Port logs, on the other hand, document the
data flow through the serial ports. This chapter outlines locations for viewing
the system and port logs.
System Status & Log
For basic system information Click System status & log. The parameters for
the system status are described in the following list.
System Information
- Identification of Digi device
Serial No. - Serial number of product
F/W Rev. - Revision number of firmware
B/L Ver. - Bootloader version
MAC address - MAC address of Digi device
Uptime - Amount of time since last reboot
Current time - : Time based on time set for Digi device
System logging - :Status of system logging either Enabled or Disabled
Send system log by email - Condition for notification:
PC card type - :Description of PC card if configured
PC card model - :Model of PC card if configured
Power status - :Dual power (1 - Normal, 2 - Normal)
Model No.
Chapter 5
45
Enabling Log Storage Location
IP Information
IP mode -
Method for setting IP address either Static, DHCP, PPPoE, or
Disabled
- When the IP address will expire
IP address - Actual IP address
Subnet mask - Address of the Subnet mask
Gateway - Address of the Gateway
Receive/Transmit errors - Number of errors from receiving or transmitting
Primary DNS - IP address of the primary DNS
Secondary DNS - IP address of the secondary DNS
IP expiration
Enabling Log Storage Location
Enable NFS Server
You can save log data to an NFS server, but the NFS server must be
configured with read and write privileges. To use an NFS server, you must
specify the NFS server’s IP address and its mounting path. To enable the NFS
server for port or system logging, do the following:
1. Access the web interface.
2. Under the Network heading, Click NFS server configuration.
NFS service - Enabled or disabled.
Primary NFS server name -IP address of NFS server or
Mounting path on primary NFS server - Directory to primary NFS server
Primary NFS timeout - Interval in seconds before timeout (5-3600)
Primary NFS mount retrying interval - Interval in second between attempts to
connect (5-3600)
Enable/Disable encrypted primary NFS server - If server supports encrypted
NFS server
Encrypted primary NFS server user - User name of server
Encrypted primary NFS server password - Password
Confirm Encrypted primary NFS server password - Repeat Password
Secondary NFS service- Enabled or Disabled
Secondary NFS server name - Name of server
Mounting path on secondary NFS server - Directory to server
Secondary NFS timeout (sec, 5-3600) - Timeout in seconds
Secondary NFS mount retrying interval (sec, 5-3600) - Retry interval in seconds
Enable/Disable encrypted secondary NFS server - If secondary server supports
encrypted NFS server
Encrypted secondary NFS server user - User name
Encrypted secondary NFS server password - Password
Confirm secondary NFS server password - Repeat password
3. To activate NFS logging, choose Enable.
46
Chapter 5
System Status and Port Logging
4. Enter the IP address of the primary and secondary (if applicable) NFS
server and the mounting path of each.
5. Click Save & apply.
Alert for NFS Server Disconnect
You can also set up an email alert and/or an SNMP trap configuration for an
NFS server disconnect. To configure this feature, use this procedure.
1. Farther down the NFS Configuration screen, at the Email alert
configuration, select Enable.
2. Enter the Title of email and the Recipient's email address.
3. For an SNMP trap configuration select Enable NFS disconnection trap
4. Select Enable for Use global SNMP configuration, and enter the IP
information for Trap receiver settings.
5. Click Save & apply.
Enable Server
To enable the Passport unit for system or port logging on a syslog server:
1. Access the web interface.
Chapter 5
47
Enabling Log Storage Location
2. Under the Systems Status and Logging heading, click SYSLOG-NG
Configuration.
3. Choose Enable.
4. Enter the IP address of the primary and secondary (if applicable) syslog
server, and select the syslog facility from the drop down menu.
5. Click Save & apply.
48
Chapter 5
System Status and Port Logging
Enable a Compact-flash Card
The compact-flash card must be installed and configured on the Passport unit
before it can be used for system logging or storing the Passport unit’s
configuration information. When storing log files to an external flash card, the
size of the available storage is dependent on both the size of the card and the
port count of the Passport unit used. The maximum settings for log file sizes
are listed in the following table. See also Adding a Compact-flash Card on
page 33.
Total Flash
Card Size
Passport
System Log
Port Log
(per port)
8
4.6
3.1M
16
4.6
1.53M
32
4.6
762K
48
4.6
500K
8
9.2
6.2M
16
9.2
3.1M
32
9.2
1.53M
48
9.2
1.02M
8
18.4
12.3M
16
18.4
6.2M
32
18.4
3.1M
48
18.4
2.0M
8
36.8
24.6M
16
36.8
12.3M
32
36.8
6.2M
48
36.8
4.1M
32
Total Memory
Used
29M
64
58M
128
118M
256
236M
Enable the Passport Unit’s Memory
The Passport unit’s memory is already enabled for port logging and needs to
be configured only for system logs or port logs. When storing log files to the
Passport unit’s local memory, a total of 3.5M is available. The amount of
memory per serial port is dependent on the port count of the Passport unit
used. The log file sizes shown in the following table are maximum settings.
See also Configuring System Logging on page 50.
Chapter 5
49
Configuring System Logging
Passport
System Log
8
Port Log
(per port)
Total Memory Used
400K
16
200K
300K
3.5M
32
100K
48
66K
Configuring System Logging
To configure the Passport unit for system logging, do the following:
1. Access the web interface.
2. Under System status & log, click System logging.
3. Choose Enabled for System logging and the log buffer size.
4. From the System log storage location, choose the location from the drop
down menu. The choices are dependent on what you have enabled and/or
installed. The Passport unit’s memory choice is always available.
System logging - Enable or Disable
System log storage location - Memory, Flash Media, or NFS server
System log buffer size (KB, 300 max) - Log buffer size in KB
Automatic backup on mounting This parameter defines the action taken if the
NFS partition or Flash media is mounted or re-mounted.
• Enable: rename the existing log file by adding a -xx with xx being a
incrementing number.
• Disable: keep writing to the existing log file. Send system log by Email
Number of log messages to send in an email (1-100) - Number of messages
System log recipient’s mail address - Email address for log recipient
50
Chapter 5
System Status and Port Logging
5. Choose to enable or disable email alerts and the number of log messages
to send. The default value is 5 seconds for the delay in log email
messages.Enter the contact email address.
6. Click Save & apply
Viewing System Logs
The system logs can be viewed from the web interface on the System logging
page or from the location where they have been saved. The following table
lists the file locations of the system logs.
System Logfile
Log Storage
File Location
Digi memory
/tmp/logs
Compact-flash card
/mnt/flash/logs
Syslog server
must be viewed on the syslog server
NFS server
/mnt/nfs/logs
USB
Configure Port Logging
If a serial port is configured for console server mode, the port logging feature
can be enabled. Port logging allows you to save serial data to the memory of
the Passport unit, a compact-flash card, a syslog server, or to an NFS server. If
Chapter 5
51
Configure Port Logging
the memory is used for port logging, all data is cleared when the system’s
power is turned off.
You can also define alarm keywords for each serial port and send email alerts
or SNMP traps to enable unattended serial data monitoring. The following
steps configure a serial port for port logging in console server mode.
1. Access the web interface.
2. Under the Serial port heading, click Configuration.
3. Choose All or the Individual port, and then Port logging.
Automatic backup on mounting This parameter defines the action taken if a
NFS partition of a CF card is mounted or re-mounted.
• Enable: rename the existing log file by adding a -xx with xx being an
incremented number.
• Disable: keep writing to the existing log file.
4. Click Save & apply.
Note:
When port logging is enabled, a Port Event Handling page is available to create
alarm keywords and send alerts. See Chapter Alerts and Notifications on page 69
for more information.
Viewing Port Logs
The port logs can be viewed from the web interface on the Port logging page
or from the location where they have been saved. The following table lists the
file locations of the system logs.
52
Chapter 5
System Status and Port Logging
Port Logfile
Log Storage
File Location
Digi memory
/tmp/port#data
Compact-flash card
/mnt/flash/port#data
Syslog server
must be viewed from the syslog server
NFS server
/mnt/nfs/port#data
To view the port logs on the NFS server for port number 5, enter the following
command:
more /mnt/nfs/port5data
Partial logfiles can also be viewed on the web interface by going to Serial port
> Configuration > select a port # you want to view > Port logging.
Chapter 5
53
Configuring Ports
Chapter 5
Configuring Ports
Introduction
This chapter provides information on configuring serial ports. Key port
configuration attributes include whether or not the port is enabled or disabled,
the host mode, which defines a type of communication between the port and a
remote host, the protocol, authentication, user access restrictions, and serial
communication attributes. It also covers RemotePortstm support.
Enabling and Disabling the Ports
All serial ports may be enabled or disabled individually or as a group from the
web interface.
1. Click Serial port > Configuration > Port number or all
2. Select Port Management > Enable or Disable from the drop down menu.
3. Click Save to flash and continue with other configurations or click Save & apply.
RealPort Support
The Digi supplied RealPort driver provides a logical connection from a host
computer to the physical serial port on the Digi Passport, regardless of where
it is located on the network. The software is installed directly on the host and
allows applications to talk to devices across a network as though the devices
were directly attached to the host. In actuality, the devices are connected to a
Chapter 6
55
RealPort Support
Digi device server or terminal server somewhere on the network.
RealPort is unique among COM port re-directors because it is the only
implementation that allows multiple connections to multiple ports over a single
TCP/IP connection. Other implementations require a separate TCP/IP
connection for each serial port. Full hardware and software flow control is also
included.
When you use RealPort to communicate with a serial port on the Digi
Passport, the other capabilities of the Digi Passport are not available for that
port. That is to say that the Digi Passport unit can be used for console
management or for RealPort COM re-direction but not both at the same time.
To enable RealPort use the following procedure.
1. To enable RealPort click Serial port > Configuration > Port number.
2. Select Port Management > Enable this port from the drop down menu.
3. Select Enable RealPort support from the drop down menu.
4. Click Save to flash and continue with other configurations or click Save & apply.
56
Chapter 6
Configuring Ports
Resetting Ports
The Digi Passport unit allows you to restart all processes associated with a
port and to disconnect all sessions.
To reset an individual port:
1. Click Serial port > Configuration > Port number.
2. Click Reset this port: Reset.
Reset Individual Port Settings
Individual ports can be reverted to factory defaults.
1. Click Serial port > Configuration > Port number.
2. Click Set this port as factory default: Set.
Port Title
The Digi Passport unit offers multiple ways to configure the port title; both
manually and automatically. The default is set to “Port Title # xx” with xx being
the port-number.
Automatic Device Recognition allows the Digi Passport unit to evaluate the
attached devices and populate the port title. Additionally the Digi Passport unit
can generate a SNMP trap or send an e-mail in case the response of the
device changes or if it stops responding.
If Active detect is selected, a configurable probe string (carriage return =0x0d
by default) is sent to the console port and the response is saved to a file at
/var/run/systemrep_raw.portxx with xx being the port number.
This file is parsed using a script /tmp/cnf/active_detect and the operating
system and device name are written to files: /var/run/HostnamePortxx and
/var/run/OSPortxx.
If Passive detect is selected, no probe string is sent to the attached device but
the port buffer is analyzed.
The script /tmp/cnf/passive_detect is executed and the results are saved to
files: /var/run/HostnamePortxx and /var/run/OSPortxx.
The commands to parse the system response are user customizable, so if a
device is not recognized by the Digi Passport unit, the root user may add a rule
to the appropriate file to allow it to be properly recognized.
After editing the scripts as either active_detect or passive_detect, save them to
flash using the saveconf command so they are not lost after a reboot.
Configuring Automatic Device Recognition
Configure a serial port for Automatic Device Recognition.
1. Access the web interface.
2. Under the Serial Port heading, Click Configuration.
3. Choose All or an Individual port > Serial port parameters.
4. Edit the fields as they apply to your configuration.
Chapter 6
57
Configuring Automatic Device Recognition
Automatic detection -
Enable or disable automatic detection of devices
Use detected port title - Enable if you want the Digi Passport unit to automatically
use the results of the detection mechanism to populate the port title. Disable if
you want the default port title. If you choose Disable, you can still use the
alarm feature.
Port title - Manually entered or automatically populated title of the port.
The Digi Passport unit allows access to a port by using only the port title,
making it unnecessary to know the serial port number.
The default is set to “Port Title xx” with xx being the port number.
Probe string - The probe string is an ASCII string that is sent to the device.
Special characters are coded in hexadecimal values like:
CR
\x0d
LF
\x0a
ESC
\x1B
Examples are:
Parse string
output
root\x0d\x0a
root<CR><LF>
\x1Btest\x0d
<ESC>test<CR>
\x1B test\x0d
<ESC><Space>test<CR>
\x1b\x20test\x0D
<ESC><Space>test<CR>
\x1B\x20\x74\x65\x73\x74\x0d
<ESC><Space>test<CR>
Detected OS - Displays the result of the Active or Passive detection process.
Device detection method - If Active is selected a probe string is periodically sent
to the device and the response is analyzed. If Passive is selected, the port
58
Chapter 6
Configuring Ports
logging is parsed to determine the device name and the OS.
Detection initiation - Active only if automatic detection is Enabled. Periodically or
If new device is detected are the choices in the drop down menu. If
Periodically is selected, the probe string is sent once every n minutes to the
device while no connection is active to the serial port. When If new device is
detected is selected, the probe string is only sent if a change on the DSR
signal on the serial port is detected. Normally a device will activate the DSR
signal if the serial port becomes active.
Detection delay - The delay before the first active detect process is started and
between active detections.
5. Click Save & apply.
Apply all Ports Settings
The Digi Passport unit supports managing all ports simultaneously. If changes
are made to the page “all ports”, they are automatically applied to all ports. You
can choose to exclude ports from this feature.
To enable/disable this feature for a port:
1. Access the web interface.
2. Under the Serial Port heading, click Configuration.
3. Choose an individual port > Apply Port Settings.
4. Select Enable or Disable from the drop down menu.
5. Click Save to flash and continue with other configurations or click Save & apply.
Note:
When changing a parameter for all ports, all settings of the complete page are
applied to all ports.
.
Host Mode Configuration
The Digi Passport unit provides four modes of communication between serial
Chapter 6
59
Host Mode Configuration
devices and remote hosts. Console server, terminal server, dial-in modem, and
dial-in terminal server. These are described in the following sections.
Console Server Mode
Configuring a serial port as a console server creates a TCP socket on the Digi
Passport unit that listens for a Telnet or SSH client connection. When you
connect to the TCP socket, you have access to the device attached to the
serial port as though the device were connected directly to the network.
RawTCP is also supported with the Console Server Mode.
Connection request
serial
Terminal Server Mode
In terminal server mode, the Digi Passport unit’s serial port is configured to wait for
data from the device connected to the port. If data is detected, the Digi Passport
unit starts a TCP session as a Telnet or SSH client to a pre-defined server. The
server must be defined by you before the port can be configured for a Telnet or
SSH client. This mode is used when you want to access servers on the network
from a serial terminal. RawTCP is also supported with the Terminal Server Mode.
60
Chapter 6
Configuring Ports
Connection request
terminals
serial
Dial-In Modem Mode
In this mode, the Digi Passport unit assumes an external modem is attached to
the serial port and is waiting for a dial-in connection from a remote site. When
a user dials-in using a terminal application, the Digi Passport unit accepts the
connection and displays the appropriate prompt or menu for you that logged
in. Example: User ’root’ would see the command line interface (CLI), whereas
the user ’admin’ would see the config menu or CLI depending on the shell for
that user.
Dial-In Terminal Server
Dial-in terminal server mode is a combination of the terminal server mode and
the dial-in modem mode. In the dial-in terminal server mode, the Digi Passport
unit assumes the serial port is connected to an external modem and is waiting
for a dial-in connection from a remote site. When you dial-in using terminal
applications, the Digi Passport unit accepts the connection as a Telnet or SSH
client to a pre-defined server. This mode is most frequently used when you
want to use modems to access servers on a network.
Chapter 6
61
Configuring Host Mode
Configuring Host Mode
To configure a serial port for host mode, enter the values in the applicable
fields. To access the Host mode configuration screen, do the following:
1. Access the web interface.
2. Under the Serial Port heading, click Configuration.
3. Choose All or an Individual port > Host mode configuration.
4. Fill in the highlighted fields as they apply to your configuration.
Host mode - The options are console server mode, terminal server mode,
dial-in modem mode, and dial-in terminal server mode.
Type of console server - The options are MS SAC - which you use to provide
a graphic user interface to the Windows Server 2003 Special
Administration Console (see "Microsoft SAC Support" on page 107) and
Other, which you use in all other cases.
Rackable Systems Mgmt Card - Enable to use Rackable Management card.
Enable/Disable assigned IP - Determines whether an IP address will be
assigned to the port. The default is Disabled.
Assigned IP - Also known as alternate IP, this field assigns an IP address to
the port, enabling you to Telnet directly to the serial port using an IP
address (without having to specify a TCP port).
Listening TCP port - This is the TCP port you will specify when connecting
directly to the port using Telnet or SSH.
Protocol - The options are SSH, RawTCP, and Telnet.
Inactivity timeout - In seconds, the time set for inactivity to trigger an action.
Setting the timeout to 0 (zero) means no timeout.
Enable/Disable port escape sequence - Allows the port escape sequence to
function.
62
Chapter 6
Configuring Ports
The key combination to initiate port escape.
Port break sequence - The sequence of characters that sends a break
character to a device.
Use comment - Determines whether a port user is prompted to add a
comment each time the port is accessed.
Quick connect via - Determines method for connecting to a port when in
console server mode. Available with Telnet.
Web applet encoding - Supported languages for Java terminal.
Port escape sequence -
5. Click Save & apply.
Supported Protocols
In configuring a serial port, you have three protocol options. The three
protocols available are: RawTCP, SSH, and Telnet. Choose SSH as the
The Digi Passport
unit supports the
protocol when logging in from an SSH client program to access a port. Choose
ability to choose
RawTCP when connecting directly to a TCP socket. Choose Telnet when
one of three
different protocol
logging in from a Telnet client program and accessing the ports. Use the Host
options for each
mode configuration page in the web interface to select the correct protocol.
port: SSH, Raw
.
TCP, and Telnet.
Chapter 6
63
Serial Port Parameters
Serial Port Parameters
In attaching a serial device to the Digi Passport unit’s serial port, the port
parameters must match. The serial ports by default are enabled, meaning you
have full access to the port. To configure the port parameters for the Digi
Passport unit, do the following:
1. Access the web interface.
2. Under the Serial Port heading, Click Configuration.
3. Choose All or an Individual port > Serial port parameters.
4. Fill in the serial port parameters. The following are the defaults: bps=9600,
data bits=8, parity=none, stop bits=1, flow control=none, and DTR
behavior=High when open.
5. Click Save & apply
DTR Behavior
DTR can be set on the serial port to one of three settings: always high, always
low, or High when open. Setting the DTR to High when open keeps the DTR
high if a TCP connection is established. The DTR setting cannot be set by you
when the host mode is configured for dial-in modem or dial-in terminal server
mode.
Inter-character Timeout
This setting is only available when the host mode protocol is set for RawTCP.
The parameter sets the time value for the Digi Passport unit to transfer data
stored in the buffer. The Digi Passport unit transfers data when the buffer is full
using the TCP/IP protocol. However, if it is not full, the Digi Passport unit will
also transfer data dependent on the timeout value selected.
64
Chapter 6
Configuring Ports
Specialty Use of Port -When Data is Processed in Chunks
Some applications are written to process only chunks of data rather than
continuous streams of data.
The Digi Passport unit supports ’chunking’ holding back data from the serial
device to the application on the network until it detects a delimiter - at which
point it sends the data to the application.
To configure a port for this mode:
1. Open a web connection to the Digi Passport unit.
2. Click Serial Port > Configuration.
3. Select All ports to configure.
4. Click Host Mode configuration.
5. Under Protocol, select RawTCP.
6) Select Serial port parameters
7) Configure the delimiter and supporting settings. Descriptions of the options
follow.
Enable/Disable delimiter --Allows deliminator to function.
Delimiter - Define the sequence that should be received before forwarding
the data to the application
Delimiter option - with delimiters - sends the delimiter as part of the data to
the application
without delimiters - remove the delimiter before sending the data to the
Chapter 6
65
Remote Ports
application
- In msec (1-10000) If no delimiter is detected
the data is delivered after this timeout has elapsed.
Inter character time-out timeout
Remote Ports
The Digi Passport unit supports RemotePorts. RemotePorts are any type of
port that can be accessed using Telnet, SSH, or Raw TCP protocol. This
includes connections to Digi PortServer Terminal Servers, Sun ALOM ports,
and IPMI management ports. This feature establishes the Digi Passport unit
as the central access system for any kind of text based out-of-band
management. Using the Digi Passport unit as a central access system has
multiple advantages:
• Central point of access
• Central user authentication
• Capturing of every user transaction on the remote system
• Keyword monitoring and alarming
• Centralized access to serial-based and IPMI consoles
Remote ports also provide the additional capabilities described in the sections
on Port Logging, Alerts and Notifications, and freeKVM
Configure Remote Ports
To configure a remote port use the following procedure.
1. Access the Digi Passport unit’s web interface
2. Under the Serial Port heading click Configuration.
3. Scroll down the page to the section called Remote port configuration.
4. Enter the port title and click Add.
A pop-up window will appear to confirm the action.
5. Click the port title to access the configuration menus.
6. Select Remote port parameters
7. Enter the IP address, port number, and protocol to use.
8. Confirm your selections by clicking Save &apply. A pop-up window will
appear to confirm the successful execution.
Note:
If you want to use a Digi PortServer TS 2 as remote device you would configure:
IP address as assigned, IP port 2001 for port 1 or 2002 for port 2 and telnet or
2501/ 2502 when using SSH as protocol.
All other settings of the remote port are equivalent to the settings of a local
serial port.
Accessing a remote port
You can connect to a remote port using the web, Telnet or SSH client. You can
Also use the port access menu or a custom menu to simplify navigation
66
Chapter 6
Configuring Ports
Web Access
Click Serial ports > Connection > Port number.
Remote ports are sorted below the physical serial ports as the next available
port number.
Telnet
Telnet to the IP and the port number (the specific port number is defined on
the ’Host mode configuration’ page.
telnet 143.191.3.9 7051
SSH to the port number
SSH to the IP and the port number (the specific port number is defined on
the ’Host mode configuration’ page).
SSH to the port name
SSH to the IP and the port number (the specific port number is defined on
the ’Host mode configuration’ page).
Ssh user-name:’t=port-title’@ip-Address
Ssh sunadmin:’t=Switch3level’:@MainDigi
You can access a remote port just like any local port:
- directly using the portnumber
Note:
Chapter 6
The parameters of the remote port are equivalent to regular serial ports. Enter any
additional parameters for the remote and click Save & apply or Apply all changes.
67
Alerts and Notifications
Alerts and Notifications
Chapter 6
Introduction
The Digi Passport unit can be configured for system alerts and notifications. It
sends email messages when the number of system log messages reaches a
certain value or when an alarm message is detected in the serial port data.
The Digi Passport unit uses SMTP (Simple Mail Transfer Protocol) for sending
the notifications. To use SMTP, the system administrator must configure a
valid SMTP server for sending the emails. The Digi Passport unit supports
three types of SMTP servers: SMTP server without authentication, SMTP
server with authentication, and POP before SMTP.
The Digi Passport unit also supports SNMP (Simple Network Management
Protocol), a protocol used to manage a network and monitor devices on a
network. System and port alerts can also be sent using SNMP traps. The Digi
Passport unit supports both versions 1, 2, and 3 of the SNMP protocol. The
main function of SNMP on the Digi Passport unit is to allow a system
administrator to query remote devices for information.
PANIC
serial
Chapter 7
PANIC
69
Configuring SMTP Alerts
Configuring SMTP Alerts
Most SMTP servers check the sender’s email address with the host domain
name to verify the address as authentic. Consequently, when assigning an
email address for the device email address, any arbitrary username with the
registered hostname may be used. An example is [email protected]
To configure the Digi Passport unit for SMTP alerts, the following parameters
are required:
SMTP server - Use either the hostname or the IP address.
Device mail address - Specify the sender’s email address for the log and
alarm delivery.
SMTP mode - Specify the type of SMTP server to use.
Username and password - These fields are required for POP before SMTP
and SMTP with authentication servers.
To configure SMTP alerts on the Digi Passport unit, do the following:
1. Access the web interface.
2. Under the Network heading, choose SMTP configuration.
3. Fill in the required fields. SMTP with authentication and POP before SMTP
require usernames and passwords.
4. Click Save & apply.
SNMP Information
Applications such as an NMS (Network Management System) or an SNMP
browser can exchange information with the Digi Passport unit and control
The Digi Passport unit
actions to the unit. The protocol functions defined for SNMP includes GET,
supports SNMP
SET, GET-Next, GET-Bulk, and TRAP. Below are the definitions of the protocol
authentication,
power on, and
functions found in SNMP. Authentication, power on, link up, login, NFS,
link up traps.
Samba, Power Management, Power Fail and IPMI traps are supported.
.
Protocol
70
Function
GET
Queries a device for more information
SET
Makes changes to a device’s state
GET-Next
After an initial GET query, goes to the next value
GET-Bulk
Retrieves tables of information and security functions
TRAP
Notifies a system administrator of a significant event
Chapter 7
Alerts and Notifications
Traps
There are additional traps that can be set at the port level. The following table
shows where the trap is under Serial port > Configuration on the web
interface, trap name, configure options, and the trap functions.
Trap Location
Trap Name
Function
Port access menu
Port login trap
Notify about any login action to the port access menu
(succeed and fail)
Alert configuration
Port login trap
Notify about login to this specific port (succeed and fail)
(only available if host mode is set to "Console server")
Alert configuration
Device connection trap
Notify about a change of the DTR signal line (only
available if host mode is set to "Console server")
Alert configuration
Active detection trap
Notify about changes in the device's response to the
probe string (see also "Automatic Device Discovery
Protocol ADDP" on page 22, only available if host mode is
set to "Console server")
Alert configuration
Dial-in modem test trap
Notify about modem test (succeed and fail) (only available
if host mode is set to "Dial-in modem")
Port event handling
Keyword notification trap
Notify about the occurrence of a keyword in the port log
(only available if host mode is set to "Console server")
The MIBs for applicable to the Digi Passport unit can be found on the Passport
CD and at http://www.digi.com/support/ under Digi Passport utilities.
Configuring SNMP v1 or v2
To configure the Digi Passport unit for SNMP do the following:
1. Access the Digi Passport unit’s web interface.
2. Under the Network heading, choose SNMP configuration.
3. Fill in information for the MIB-II system objects section and choose Yes
under EnableAuthenTrap. The fields are described in the following section:
sysContact - Identity of the contact person managing the MIB-II system.
sysName - The name identifying the system. By convention, this is the fully
qualified domain name of the Digi Passport unit. An example is:
[email protected]
sysLocation. - The physical location of the unit such as Room 264 or
Engineering Lab.
sysService (Read only). - A series of values, separated by commas,
indicating the set of services the system provides. By default, the Digi
Passport unit only supports Application (7) service level.
EnablePowerOnTrap. - Determines whether the SNMP agent generates a
trap each time the Digi Passport unit is started.
EnableAuthenTrap. - Indicates whether the SNMP agent process is permitted
to generate authentication failure traps.
EnableLinkUpTrap. - Determines whether the SNMP agent generates a trap
each time the network connection comes up.
Chapter 7
71
Managing the SNMP Protocol
EnableLoginTrap - Determines whether the SNMP agent generates a trap for
each login.
EnableLinkDownTrap.
Note:
Trap values override all other configuration information, meaning all other
authentication failure traps can be disabled with this setting.
4. Enter Access control settings based on the following field descriptions:
IP Address - Defines what applications can access the Digi Passport unit’s
SNMP agent to exchange information and control actions. If no IP
addresses are listed, any application can access the SNMP agent.
Community - The options are public or private. The Community string can
be anything but they must match what you use in your SNMP software.
Permissions - The options are Read only or Read/Write.
5. Enter Trap receiver settings based on the following field descriptions:
IP Address - Enter the IP address of the device receiving the trap alerts.
Community - The options are public or private. The Community string can
be anything but they must match what you use in your SNMP software.
Version - Choose the SNMP version, either version 1 or version 2c.
6. Click Save & apply.
Managing the SNMP Protocol
The Digi Passport unit’s SNMP protocol can be managed using an NMS or
SNMP browser. However, before the NMS or SNMP browser can access the
data, the Access control settings must list the IP address of the host from
which the browser is executed. See the preceding graphic for details.
SNMPv3 Configuration
72
Chapter 7
Alerts and Notifications
SNMPv3 allows for authentication and encryption thus making it more secure
than SNMPv1 or SNMPv2. This section demonstrates the steps required to
configure SNMPv3 access control and SNMPv3 traps.
1. Open the main SNMP configuration page.
2. Next you need to add a user to the “Access control settings (SNMPv3)”
section.
3. Select the number “1” and a new menu will open.
Chapter 7
73
Managing the SNMP Protocol
4. Fill in the “User name” field, this is a user that is set up for SNMPv3 access
in your SNMP browser software.
5. Select your Security level, this should match what is configured in you
SNMPv3 software.
6. Select the Authentication protocol, again this must match what is
configured in your SNMPv3 software.
7. Supply and confirm the password for the above user, again this must
match what is configured in your SNMPv3 software.
8. Next follow the same steps as above for the Privacy protocol.
9. Finally select the appropriate permission level and Save to flash.
10. Now open the main SNMP configuration page again it should look
something like this.
74
Chapter 7
Alerts and Notifications
11. Next you need to configure the Trap receiver settings. Select number 1
from this section.
12. The resulting menu opens.
13. In this menu select the “Trap receiver enable/disable check box then
select v3 from the version dropdown. The resulting menu will open.
Chapter 7
75
Configuring Port Event Handling
14. In this menu fill in the IP address of the Trap receiver.
15. Fill in the User name, this is the same user from the SNMPv3 software.
16. Select the security level and a new menu will open. It should look this.
17. Use the same steps as in the “Access control settings” section for the
Authentication and Privacy Protocols and their passwords.
18. Fill in the engine ID this is supplied by the SNMPv3 software. Make sure
that you delete the spaces from the original engine ID.
Configuring Port Event Handling
Once an SMTP or SNMP server has been configured, it can be used to send
port-related alerts and notifications. The following describes how to configure a
port for port event handling.
1. Access the web interface.
2. Choose Serial port > Configuration.
3. Choose a port to configure and then Port logging.
4. Select Enable.
5. Choose Save & apply.
6. Choose Port event handling.
76
Chapter 7
Alerts and Notifications
The following page appears.
7. Select an action and enter the keyword for the port event handling.
8. Enable Email notification.
Note:
It is assumed that SMTP is configured first. If not, see "Configuring SMTP Alerts"
on page 70.
9. Enter the title of the Email (subject line).
10. Enable or Disable Case sensitive.
11. Enter the Email recipient’s address.
12. Enable SNMP trap notification.
13. Enter the title of the trap.
14. Choose either to use the global SNMP settings by enabling "Use global
SNMP configuration" or specify special settings for this port.
Chapter 7
77
Config Alerts for Automatic Device Recognition (ADR)
15. Enter the IP address of the trap receiver.
16. Enter the SNMP community
17. Select the version.
18. Complete configuration and then choose Save & apply.
Note:
Key word is any text string that will trigger an alert when it traverses the serial port.
Config Alerts for Automatic Device Recognition (ADR)
Before configuring the alerts for Automatic Device Recognition, be sure you
have configured the port for ADR as described in "Configuring Automatic
Device Recognition" on page 57.
1. Access the web interface.
2. Under the Serial Port heading, Click Configuration.
3. Choose All or an Individual port > Alert Configuration.
78
Chapter 7
Alerts and Notifications
4. Follow the Email Alert steps to configure the email alert or follow the SMTP
Notification to configure SMTP.
Email Alert
Enable "Email Alert for active
detection"
Enter the Title of email
Enter Name and email address
where the email should be sent.
SMTP Notification
Enable "Active detection trap"
Configure the trap receiver by one of the
following two ways:
Enter "Use global SNMP configuration"
OR
Enter the IP address of the trap receiver,
the SNMP trap community and select the
version
5. Complete configuration and choose Save & apply.
Chapter 7
79
Config Alerts for Automatic Device Recognition (ADR)
80
Chapter 7
Intelligent Platform Management Interface
Intelligent Platform
Management Interface
Chapter 6
Introduction
Intelligent Platform Management Interface (IPMI) is a specification for the
equipment that monitors the physical environment and condition of a computer
hardware server. The specification is intended to cover the regulation of
temperature, voltage and power, and to ensure the proper operation of the
firmware.
IPMI works with hardware servers regardless of the operating platform or other
software they may run. IPMI allows an administrator to manage multiple
servers from a single location by means of a user-friendly interface. Critical
system events for each server can be logged. Settings for each basic
input/output system (BIOS) can be monitored or changed. Servers can be
remotely and independently powered on or off, rebooted, or reset as
necessary.
The following instructions explain the method for configuring IPMI including
SOL (Serial Over Lan) on a Remote port. Configuring IPMI on a standard
serial port is identical except there is no SOL section.
Procedure
1. In the Web select Serial port configuration and then select the port that you
want to configure for IPMI.
2. From the menu that opens select “Host mode configuration” from the
resulting (shown below) select “Enable” for IPMI and save to flash.
Chapter 8
81
Introduction
3. Next select “Remote port parameters” from the main configuration page.
The resulting menu will open.
82
Chapter 8
Intelligent Platform Management Interface
4. Fill in the Destination IP field with the address of the server you want to
monitor. Generally this will be the address assigned to the BMC (Baseboard Management Controller).
5. Fill in the Destination port, normally 623 is the port used for IPMI, but this
may vary on individual servers.
6. Select the Protocol RMCP+ is the protocol used for SOL.
7. The OEM type should be set to “None” in most cases. You should only use
“Intel IPMI 2.0 BMC” if your server has an actual Intel 2.0 BMC.
8. Save to Flash. Next from the main configuration page select “IPMI Configuration” and the resulting menu will open.
Chapter 8
83
Introduction
9. Fill in the Destination IP field with the address of the server you want to
monitor. Generally this will be the address assigned to the BMC (Baseboard Management Controller). If you are using a remote port this value
will be supplied from the “Remote port parameters”.
10. Fill in the Destination port, normally 623 is the port used for IPMI, but this
may vary on individual servers. If you are using a remote port this value will
be supplied from the “Remote port parameters”.
11. Fill in the “User name” field. This is a user configured on the server that can
access the BMC.
12. Supply and confirm the password for the above user.
13. Sensor alert configuration is where you can create a list of sensors on your
server that you would like to receive notifications from.
Connecting to you server via IPMI
84
Chapter 8
Intelligent Platform Management Interface
1. To connect to your server via the IPMI GUI select the serial port connection
page.
2. Select the serial port that is configured for IPMI and the resulting menu will
open.
3. Select the “IPMI GUI Access” link this will connect to your server via IPMI.
The resulting page will open.
Chapter 8
85
Introduction
4. From this page you can choose which BMC statistics to monitor, power
cycle the server or make an SOL connection to the server’s console port.
5. To choose what you would like to monitor click the drop down arrow and a
list will open.
6. In the example shown below we have chosen BMC hardware information.
The resulting page is displayed. The information displayed on this page will
vary between server manufacturers.
86
Chapter 8
Intelligent Platform Management Interface
7. To make an SOL connection to your servers console port click the “Connect” button the resulting window will open. The example shown below is a
console connection to a Windows 2003 servers SAC port.
Chapter 8
87
Introduction
88
Chapter 8
User, Security, and Authentication Configuration and Administration
f
Chapter 8
U s e r, S e c u r i t y, a n d A u t h e n t i c a t i o n
Configuration and Administration
Introduction
The Digi Passport unit provides four methods for controlling access to the
network and the devices on the network:
• Restricting or permitting IP filtering
This method allows or prevents users with specific IP addresses from
accessing devices or serial ports on the network. IP filtering can be
permitted or restricted for all ports globally or per port.
• Restricting or permitting specific users
You easily can add users to or remove them from a list of restricted or
permitted users list.
• Enabling sniff session access
This method allows multiple users to access a single port.
• Using a central point (System administration > Security profile) where you
establish security parameters per network, port, or password.
The Digi Passport unit supports several authentication methods, including:
• Local
• RADIUS
• TACACS+
• LDAP
• Kerberos (The Kerberos module is not part of the normal firmware
because of memory constraints. You can download the module from
http://support.digi.com and place onto /usr2/ if required. To copy files to
/usr2/, use a scp tool such as WinSCP.)
• Custom PAM. You can configure authentication so that a secondary
method is attempted if the primary method fails.
Configuring User Access Control
Another method for controlling access to the serial ports on the Digi Passport
unit is the User Access Control configuration. You can set up this configuration
either globally (using the All Ports option) or per port.
It is not necessary to have users added to the system to assign rights.
However, for the permissions or restrictions to be enforced, the username
must match exactly. The username is case sensitive, and the application does
not recognize misspellings.
To add users, click on "System administration > Users administration". For
Chapter 9
89
Configuring User Access Control
details about adding users, see "Administering Users" on page 69.
Note:
Users do not need to be configured locally; they can be defined on a remote
authentication server.
Using Access lists, you can add rights to a single user or to multiple users at
the same time. In addition, you can group multiple users and assign one,
some, or all these rights:
• Port access rights
• Port monitor rights
• Power management rights to an access list.
For more information, see "Create an Access list" on page 70.
This scenario shows a configuration with a restricted user: Joe does not have
access to the Sun server, while Mike does.
MIKE
JOE
Your strategy for assigning rights to a port can include:
• Allowing <<Everyone>> access to a port and then restricting access to
certain users -or• Specifying each individual user and their specific rights to a port
• Adding a user to an established group (Access list) with preconfigured
rights to a port.
If you check <<Everyone>>, all users, whether they are configured locally or
are using a remote authentication (such as LDAP or Kerberos), have access to
this port.
If you do not check <<Everyone>>, no users are allowed to access this port
unless they are individually listed.
When you enter usernames for access permissions or restrictions, you must
enter the username exactly as the username is listed locally or is listed on the
remote authentication server. The username is case-sensitive.
In the next example, three users are configured on the Digi Passport unit: jeff,
tim and paul. To give tim and paul read/write access and power access to this
90
Chapter 9
User, Security, and Authentication Configuration and Administration
port, you could either:
• Grant rights to paul and tim
• Restrict jeff’s rights
• Add users to an Access list (in this example. sun-users) found under
System administration > Access list. For more information, see "Create an
Access list" on page 70.
Configure User Access Privileges
To configure user access privileges:
1. Select Serial Port Configuration > All Ports (or Port #)
2. Click User access mode
3. Enter the users and their privileges, and click Add user.
Restrict a User’s Privileges
To restrict user access:
1. Under Port configuration > User access control
2. Enter privileges for <<Everyone>>.
Chapter 9
91
Configuring User Access Control
3. Enter restricted user’s name (Here it is ronk).
4. Enter the privileges this user has. (Notice that <<Everyone>> has more
access than ronk does.)
Note:
The usernames and passwords on the Digi Passport unit are case-sensitive.
Notice <<Everyone>> has access to Port, Monitor, and Power, while Jeff has
access to only Monitor, with no Port or Power access.
Change the Privileges of an Access List
1. On the same screen shown in the previous procedure, select an access list
from the drop-down box.
2. Click the Add access button, and then click and the Save & apply button.
When you add the access list, it will include Paul and Tim.
In this screen, the "sun-users" Access group has access to Port, Monitor, and
Power, while any other users (<<Everyone>>) do not have access.
92
Chapter 9
User, Security, and Authentication Configuration and Administration
Type of Users
Access Types
How to Permit or Restrict
Only specific users
have access
"Permitted Users"
Access type is unchecked for
Everyone (meaning All other
users) does not have access
By listing specific users and
checking the access types (Permitting them access)
All users have
access except for a
few "Restricted
Users"
Everyone has access to
everything by checking the
access types. If an access type
is unchecked, all users are
restricted from that access type.
By listing users and
unchecking the access type
they are restricted from using
Sniff Session
A sniff session enables multiple users to access a single serial port for viewing
the data stream. Anyone who is registered for a sniff session can access a
specific serial port — even if someone else is using the port. The Digi Passport
unit supports multiple concurrent sniff sessions.
Chapter 9
93
Configuring User Access Control
serial
log in
port 3
Sniff Session
(Read only access)
Port 3
Network (Ethernet)
log in
port 3
Main Session
(Read/write access)
Sniff session mode has four options: disabled, input, output, and both. You
configure the sniff session modes per port from the serial port configuration
page.
Enable/Disable sniff mode
•
•
Disabled - No one can enter a sniff session after the first user logs on.
Enabled - Allows all users with access the following options in sniff
mode:
Sniff session display mode
•
•
•
server output - View all data to a serial port from a remote connection
user input - View all data from a serial port to a remote connection
both - See all data transmitted or received through a serial port
Display data direction arrows
•
Enable/Disable - Displays arrows to indicate the direction of data to or
from the server. When the second user accesses the port, the global
"Port escape menu" is displayed. See "Port Escape Menu" on page 21.
Permit monitor only mode
•
•
94
Enable: A user with “Monitor" permissions can only connect to the port
in read only mode any time.
Disable: A user with “Monitor" permissions can connect if a read/write
user has a connection to the port. A read-only session is automatically
disconnected if the main user (read/write session) disconnects from the
port.
Chapter 9
User, Security, and Authentication Configuration and Administration
Security Profile
The Security Profile tab, available under System Administration > Security
Profile, provides a centralized access for enforcing site-appropriate, minimum
security parameters on the Passport. These are the available control
mechanisms:
• System Security
• Password Security (Force heightened)
System Security
•
•
•
•
•
•
•
•
Chapter 9
SNMP
The Passport allows you to use Get and Set commands for easy remote
configuration and monitoring. You can configure Get and Set individually
using the Network > SNMP Configuration interface.
This option gives you a simple method for globally disabling any SNMP
queries. (Traps always can be sent if they are configured). In the Default
configuration, SNMP is disabled.
Discovery (ADDP)
Enables/disables the discovery protocol. While this is convenient for initial
discovery of units on the network, this service is often disabled when the
system is ready for production, unless the system is deployed on a
controlled LAN.
Telnet
Disabled by default, this feature can be enabled afterward if the customer
does not require encrypted connections.
SSH
Usually remains enabled; in some environments, however, access is
allowed only by a totally out-of-band connection (hard-wired serial, dial-up
modem, or both). In such situations, the Ethernet connection is used only
for reports and alerts.
SSHv1
SSHv1 (Secure Shell Version 1). SSHv1 uses server and host keys to
authenticate systems. This service is disabled by default.
HTTP
Enables/disables access to the Digi Passport using the Web interface. By
default, HTTP is redirected to HTTPS.
HTTPS
Enables/disables access to the Digi Passport using the Web interface. This
service is enabled by default. If, however, the unit will be deployed outside
a controlled LAN, HTTPS is often disabled to limit the number of services
available.
All Ports
95
Authentication
•
•
Enables/disables access to all ports using any protocol.
Set all ports to
Specifies the protocol to be used on all ports. The default is Telnet.
Stealth Mode
Makes the Digi Passport “invisible” on the network and exposes only ports
that are used to provide access. In Stealth Mode, the Passport does not
reply to pings or traceroutes and does not respond to communication
attempts on unused TCP/UDP sockets.
Password Security
To enhance password security, you can use these settings:
• Minimum password length - Allows passwords that are 3 to 255 characters
long; also allows spaces in passwords
• Maximum password age - Specified in days. To disable this setting, enter 0.
• Enforce password complexity - Cannot include all or part of a user’s
account name. Passwords must be at least eight characters long, or
exceed Minimum password length if larger. Passwords can be up to 255
characters long and must include three of these four categories of
characters:
• English uppercase characters (A-Z)
• English lowercase characters (a-z)
• Base 10 digits (0-9)
• Non-alphabetic characters (!, $, #,%, and so on)
• Enforce password history - Cannot reuse the last nine passwords
Authentication
The Digi Passport unit supports multiple methods of user authentication,
including local, TACACS+, RADIUS, RADIUS Down-Local, LDAP, Kerberos,
and Custom PAM. The authentication protocol you use depends on your
environment.
96
Chapter 9
User, Security, and Authentication Configuration and Administration
4. Access granted
Server
1. Connection request
2. Query
User ID
PC
3. Accept
User ID
Authentication
server
Configuring Authentication Methods for Port Access
You can choose between having a single authentication method, such as
RADIUS, or an authentication method where a Local authentication service is
used in addition to the RADIUS, LDAP, TACACS+ server, or Kerberos. These
options are listed when you configure the Digi Passport unit for authentication.
To configure the Digi Passport unit for authentication, do the following:
1. Access the web interface.
2. Under the Serial port heading, choose Configuration.
3. Choose All or an Individual port > Authentication.
4. From the drop-down menu, choose an authentication method. A
configuration screen for the authentication method you choose is
displayed. This figure displays the options for setting up a RADIUS server
as the primary authentication server and Local authentication if the primary
authentication method fails.
Note:
Remote authentication to Port access menu can be obtained from Serial port >
Configuration > Port access Menu
5. Fill in the applicable fields.
6. Choose Save & apply changes.
Note: Under Serial port > Connection, The “# of User” column shows how
many users are actually connected to the port and the username of
the read/write user.
Chapter 9
97
Configuring Authentication for the Web Server
Configuring Authentication for the Web Server
1. Access the web interface.
2. Choose Network > Web server configuration.
This screen opens.
3. Choose an authentication method and then Save & apply.
When you are using remote authentication for the web server, such as
RADIUS, RADIUS Down-local, TACACS+, LDAP, Kerberos, or Custom
PAM, you must also be added to the local database. The user password
must be different from local authentication; otherwise, the Passport will
authenticate against the local database instead of the remote one. For
details, see "Administering Users" on page 69.
When your password is approved by the authentication server, the Digi
Passport unit uses the local permission rights to provide access privileges
for you to ports and the configuration.
LDAP Authentication
The Digi Passport unit supports authenticating against an LDAP-based
database, including LDAP systems running on Linux servers as well as
Microsoft Active Directory together with the LDAP gateway ADAM (Active
Directory Application Mode).
If the Digi Passport unit authenticates against an LDAP directory, all users
must be configured in one container. The Digi Passport unit will extend the
username using the LDAP search base and authenticate the user.
In the next example, the domain is called dilbert.com, the LDAP server is at
10.1.1.1, and all users with access to the Digi Passport unit are located in the
container: USA
Users
98
Chapter 9
User, Security, and Authentication Configuration and Administration
Configure the LDAP authentication as shown here:
Authentication method: LDAP server
First LDAP Server 10.1.1.1
Second LDAP Server
LDAP search base: ou=users,ou=usa,dc=dilbert,dc=com
Domain name for active directory:
If your LDAP database resides on a Microsoft system you also have to
configure the Domain name for the active directory (dilbert.com in the above
example).
Do not use this setting if you are using a non-Microsoft system as it changes
the LDAP to comply with Microsoft syntax.
Custom PAM Module
The Digi Passport unit supports custom PAM modules for remote
authentication. This allows you to create your own authentication schema or
use any other third party PAM module. The module must be compiled for the
Digi Passport unit’s environment.
Digi offers an SDK for the Digi Passport family.
To download the SDK, contact technical support at [email protected]
1. Place the custom PAM modules onto: /usr/2 on the Digi Passport unit.
2. Use an scp client (like WinSCP) to copy data to the /usr2 directory, or use
scp or ftp client on the Digi Passport unit to upload the file while logged in
as root.
3. Make sure the module is flagged to be executable (chmod 755 ...)
Note:
To activate the custom PAM module it has to be configured in the custom file
located in /etc/pam.d
4. Create a file called: /etc/pam.d/custom and add these lines:
auth required /usr2/my_pam _auth.so
session required /usr2/my_pam_ auth.so
(with the my_pam_auth.so being the "custom pam" module’s name)
Samba configuration>
Samba server
Make a shared folder to use a Windows machine for a Samba server. For a
Linux machine, run smb service.
Passport
[Network->Samba configuration]
Samba service: Enable
Chapter 9
99
Samba configuration>
Samba server name: IP address or Computer name of Samba server
Mounting path on Samba server: shared folder name (should be started with '/
'. e.g. /share)
Samba timeout (sec, 5-3600): 5 (this is a default value)
Samba mount retrying interval (sec, 5-3600): 5 (this a default value)
Samba server user: User name of Samba server
Samba server password: Password of the user
Note:
100
Samba directory will be mounted on /mnt/smb directory in passport.
Chapter 9
Custom and Default Menus
Custom and Default Menus
Chapter 9
Introduction
The Digi Passport unit has several default menus for easy configuration and
access by different users. Depending on access privileges, the menus
available are the Web Interface, Configuration Menu, and Port Access Menu.
A Custom Menu feature for creating menus is also available through the web
interface.
The Custom Menu feature enables system administrators to create menus for
specific users; in other words, system administrators can create a customized
interface to selected ports. Custom menus can only be configured via the web
however, they can only be accessed via command line (serial, telnet, or ssh)
connections.
Making Custom Menus
Before making custom menus, plan the kind of menus and menu items you
want available to your users. A good plan would include the following:
1. Add users to the system.
2. Create a menu name with sort and display features.
3. Add menu items and submenus to the new menu.
4. Assign users to the menus.
Adding Users
You cannot assign users to a menu until you have added users to the system.
To add users, do the following:
1. Access the web interface.
2. System administration > Users administration > Add
Chapter 10
101
Making Custom Menus
3. Enter the User name and User group from the drop down menu.Select
Custom menu from the drop down menu for the Shell program.
4. Click Add to add the user.
5. Continue to add users as needed.
Note: You do not need to Save to flash or Apply changes to add users.
Creating Menu Names
To make a custom menu, do the following:
1. Access the web interface.
2. Custom Menu > Configuration.
3. Enter the Menu Name to assign and click the Add Menu button.
The menu is added.
4. Click the hyperlink to the menu you just created.
5. From the drop down menu, select the way to Sort and Display items.
6. Click Save & apply.
102
Chapter 10
Custom and Default Menus
7. Repeat as required to create additional menus.
Adding Menu Items
Once you have defined a menu name and added users, you can then add
menu items. To add menu items, do the following:
1. Custom Menu > Configuration > Menu Name hyperlink for the menu you
want to configure.
2. Choose Menu Items > Add Item.
The following screen appears.
3. Fill in the desired parameters. The parameters are:
Key - Assign any letter or number except a value already used by another
menu item.
Label - Assign a label or name for the menu item.
Create new submenu - Assign a name for a new submenu that this menu item
will be assigned or linked to.
Go to existing submenu - Choose an existing submenu from the drop down
menu that this menu item will be assigned or linked to.
Connect to serial port - Connects you to a specified port.
Connect to clustered serial port - Connects you to a clustered port.
Telnet to a remote host - Enter a remote host’s IP address or hostname.
SSH (Secure Shell) to a remote host - Enter the hostname or IP address of a
remote host and the remote username.
Chapter 10
103
Default Menu
- Enter a customized command that is any valid
command on the command line with acceptable user privileges.
4. Choose Apply.
5. Repeat this procedure to add more menu items.
Execute a custom command
Note:
To add or configure submenus, select the Submenus hyperlink on the Menu
Configuration page.
Assigning Users to a Menu
Once a menu has been created, users can be assigned to the menu by doing
the following:
1. Access the web interface.
2. Configuration > Custom Menu > Menu Users.
A list of available users is displayed.
3. Choose a menu for a user by selecting a menu from the drop down
Assigned Menu list.
4. Choose Save & apply.
Default Menu
Port Access Menu
The Port Access menu is a flat (one level) menu showing all ports, port titles
and the mode of each port.
Using the Port Access menu you have a complete overview of all ports and
can initiate a connection to any of them.
When you choose to connect to a specific port, you are prompted again for the
username and password.
104
Chapter 10
Custom and Default Menus
There are multiple ways to access the PortAccess menu:
• Assigned IP address (see "Configuring Host Mode" on page 62)
• TCP/IP port 7000
• TCP/IP port 22 or 23 if the “Shell program” is set to “port access menu” for
this specific user (see chapter "Administering Users" on page 69)
• By calling “portaccessmenu” from the command line
The PortAccess menu allows simple access to each port.
By typing the number of the port to connect to, the Digi Passport unit initiates a
connection to this port using the appropriate protocol (Telnet of SSH).
You can also change your own password by using the “P” Key.
If the Digi Passport unit is configured to be the master in a master-slave
scenario, the “S” key will bring up a list of all slaves. Selecting a slave will then
spawn a connection to the Port Access Menu of the slave.
When using a Digi Passport 48, not all ports can be displayed on one screen.
Ports 33-48 can be viewed after hitting the <Enter> key.
Chapter 10
105
Microsoft SAC Support
Microsoft SA C Support
Chapter 11
About the Digi Passport Unit’s Support for Microsoft Windows Server 2003
The Digi Passport unit provides a browser-based user interface to Microsoft’s
text-based Special Administration Console (SAC), an integral part of Windows
Server 2003 Emergency Management Services (EMS). Both the English and
International versions of SAC are now supported. When a server running
Windows Server 2003 is connected to the Digi Passport unit’s serial port, key
SAC functions--normally accessed from the command line--are available from
a graphical user interface (GUI). SAC features accessible from this interface
include:
• Reset and shutdown
• Show performance values like memory utilization
• Show and configure IP settings per interface
• Show the process list and kill processes
Note:
Chapter 11
While the EMS port is available at all times using Telnet or SSH, the special GUI is
available only while SAC is active.
107
Setup Overview
Setup Overview
Setup for the Digi Passport unit SAC support is a three-step process:
1. Set up the Windows Server 2003 for SAC support. To do this, ensure that
the COM port used for console traffic is properly set up. This includes
designating a COM port for console communication and setting the port
speed (baud) appropriately. For further information please refer to Setting
Up the Windows Server 2003 Port below.
2. Cable the console port on the Windows Server 2003 to the Digi Passport
unit’s port.
3. Set up the Digi Passport unit for SAC support. See "Setting Up the Digi
Passport Unit for SAC Support" on page 108.
Setting Up the Windows Server 2003 Port
1. Sign on to the Windows Server 2003 as the administrator.
2. Access the command line.
3. Use the bootcfg command to redirect console traffic to the correct COM
port. The following is the command syntax and an example. See the
Microsoft documentation for additional information on the SAC feature.
Command Syntax
bootcfg /ems on /port com# /id # /baud 115200
where:
• com# is the COM port to which console traffic will be redirected.
• # is the is the number of the boot entry.
•
The port speed is set to the recommended rate (although you can use any
rate supported by Windows Server 2003).
Command Example
In this example, console output is redirected to COM 2, the boot entry is
specified as 1, and the port speed set to 115200.
bootcfg /ems on /port com2 /id 1 /baud 115200
Setting Up the Digi Passport Unit for SAC Support
To set up a serial port to provide access to the Windows Server 2003 console
port, do the following:
1. Access the web interface.
2. Choose Serial port > Configuration.
3. Choose a port.
4. Choose Host mode configuration.
The Host mode configuration page appears.
5. Set the Host mode to Console server and the Type of console server to MS
SAC -English (or International) console as shown in the following figure.
108
Chapter 11
Microsoft SAC Support
6. Set other fields as appropriate.
7. Click Save & apply.
8. Configure serial port communication settings, by doing the following:
a. Choose Serial port parameters from the menu.
b. Adjust settings as required. This includes ensuring that the Baud rate
matches the setting on the Windows Server 2003 serial port and Flow
control is set to None. Ignore the DTR behavior field.
c. Click Save & apply.
Accessing the Windows Server 2003 Console Port from the Digi Passport Unit’s GUI
To access the Windows Server 2003 console port, do the following:
1. Access the web interface.
2. Choose Serial port > Connection.
A screen similar to the following appears.
3. Click on the title of the port to which the Windows Server 2003 console port
is connected.
Note:
Chapter 11
If support for "Windows Server 2003" and "Rackable Systems Management Card"
109
Accessing the Windows Server 2003 Console Port from the Digi Passport Unit’s GUI
is selected a menu will appear and you must choose between the two functions.
4. Use the Digi Passport unit’s GUI to perform SAC functions. The following
table describes attributes of the controls on the GUI.
Field
110
Description
Connect
Connects to the SAC console port via the command line interface.
Restart
Reboots the Microsoft Server 2003.
Shutdown
Shuts down the Microsoft Server 2003.
Caution! This switches off the server and you can no longer access it
remotely.
Performance
Provides access to Microsoft Server 2003 status information.
Process
Provides access to the process list, which allows you to view and kill
active processes.
Serial Port
Log
Provides access to port logging information.
IP Settings
Provides access to IP settings, enabling you to verify and change settings.However, the IP settings are only temporary, you cannot change the
IP settings permanently through this method.
Chapter 11
Microsoft SAC Support
Chapter 11
111
Configuring FreeKVM
Configuring FreeKVM
Chapter 12
Introduction
The Digi Passport provides a method for gaining access to the graphical
interface of a system using the network. Using this method, FreeKVM, you
specify a connection method and IP address to use to reach the system.
Supported methods include:
• Microsoft Remote Desktop Protocol
• VNC
• XManager for X Window System
• Web redirection
• A user-defined option
An Example Configuration
This diagram shows the Digi Passport managing a Linux SuSE 9.2 system, a
Windows 2003 system, and an HPUX system.
Free Protocols
This table lists the free protocols and the client software with which each
protocol has been tested.
Chapter 12
113
Using FreeKVM with Remote Desktop Protocol
Free Protocol
Tested Client Software
Remote Desktop
Windows 2000, XP, 2003 Remote Desktop Client
Linux: rdesktop
VNC
Windows: tightVNC, realVNC, UltraVNC
Linux: vncviewer
X Window System
Windows: Xmanager
Linux/Unix: X Window System
The rest of this chapter describes how to set up FreeKVM with each of the
supported methods and connect to a system through FreeKVM.
Using FreeKVM with Remote Desktop Protocol
This section describes how to:
• Configure FreeKVM with Remote Desktop Protocol
•
Connect to a system through FreeKVM using Remote Desktop Protocol
Configuring
To set up FreeKVM with Remote Desktop protocol, follow this procedure:
1. Access the Digi Passport Web interface and log in.
2. Choose Serial Port > Configuration.
This window opens:
3. Choose the port you want to configure, and then select the FreeKVM tab.
(In this example, port 1 is selected.)
114
Chapter 12
Configuring FreeKVM
A window similar to this one opens, showing the serial port number and title:
4. Click FreeKVM configuration.
This window opens:
5. From the drop-down list next to FreeKVM configuration, select Enable.
Then, from the Client program drop-down list, select Windows remote
desktop connection.
6. If you are not using IP automatic detection, enter the IP address.
7. Click the Save & Apply button.
Note: If you are using Remote Desktop configuration and you want to use
automatic IP address detection, configure the host mode for the port to MS
Chapter 12
115
Using FreeKVM with VNC Protocol
SAC console before you configure the FreeKVM feature for the port. For
more information, see "Setting Up the Digi Passport Unit for SAC Support" on
page 108.
Connecting to a system through FreeKVM using Remote Desktop Protocol
When you connect through the Connection window, and a FreeKVM
connection is configured, you now see:
• The terminal monitor button, which connects to the raw ASCII SAC console
• A mouse button (next to the monitor icon), which connects to the FreeKVM
graphical interface
• The manage button, which connects to the SAC GUI screen
To connect through FreeKVM using Remote Desktop, follow these steps:
1. Click on the mouse icon.
2. Click OK in each of the three Java confirmation request windows.
3. The application starts and you see a message that the connection
succeeded:
This login screen opens:
4. Enter your user name and password, and then click OK.
If the application does not start, check to make sure that the application is in
the search path on your server. See "Installing Programs for FreeKVM" on
page 122.
Using FreeKVM with VNC Protocol
This section describes how to:
116
Chapter 12
Configuring FreeKVM
•
•
Configure FreeKVM with VNC Protocol
Connect to a system through FreeKVM using VNC Protocol
Configuring
To configure FreeKVM with VNC protocol, follow this procedure:
1. Access the Digi Passport Web interface and log in.
2. Choose Serial Port > Configuration.
This window opens:
3. Double-click the port you want to configure.
A window similar to this one opens, showing the serial port number and title:
Chapter 12
117
Using FreeKVM with VNC Protocol
4. Select the FreeKVM tab.
This window opens:
5. From the FreeKVM connection drop-down list, select Enable.
Then, from the Client program drop-down list, choose the VNC Client
program.
6. Adjust the VNC socket/screen number, if necessary (the default is 1).
7. Click on the Save & Apply button.
Connecting to a system through FreeKVM using VNC
When you connect through the Connection window, and a FreeKVM
connection is configured, you now see:
• The terminal monitor button, which connects to the serial console
• A mouse button (next to the monitor icon), which connects to the FreeKVM
graphical interface
118
Chapter 12
Configuring FreeKVM
To connect through FreeKVM using VNC:
1. Click on the mouse button.
2. Click OK in each of the three Java confirmation request windows.
The application starts, and you see a message that the connection
succeeded:
The FreeKVM VNC Connection opens:
3. Enter your user name and password, and click Login.
If the application does not start, check to make sure that the application is in
the search path on your server. See "Installing Programs for FreeKVM" on
page 122.
Using FreeKVM with X Window System Protocol and XManager Software
This section describes how to:
• Configure FreeKVM with X Window System Protocol and XManager
Software
• Connect to a system through FreeKVM with X Window System Protocol
and XManager Software
Configuring
To set up FreeKVM with X Window System Protocol and XManager Software,
follow this procedure.
1. Access the Digi Passport Web interface and log in.
2. Choose Serial Port > Configuration.
Chapter 12
119
Using FreeKVM with X Window System Protocol and XManager Software
You see this window:
3. Choose the port you want to configure.
A window similar to this one opens, showing the serial port number and title:
4. Choose FreeKVM configuration.
120
Chapter 12
Configuring FreeKVM
This window opens:
5. From the FreeKVM connection drop-down list, select Enable.
Then, from the Client program drop-down list, choose the Xmanager
program.
6. Click Save and Apply.
Connecting to a system through FreeKVM using Xmanager
When you connect through the Connection window, and a FreeKVM
connection is configured, you now see:
• The terminal monitor button, which connects to the serial console
• A mouse button (next to the monitor icon), which connects to the FreeKVM
graphical interface
To connect through FreeKVM using X Window System Protocol and
XManager Software:
1. Click on the mouse icon.
Chapter 12
121
Web Redirection
2. Click OK for each of the three Java requests in pop-up windows.
The application starts, and you see a message that the connection
succeeded:
The FreeKVM VNC Connection comes up:
3. Enter your user name and password, and click OK.
If the application does not start, check to make sure that the application is in
the search path on your server. See "Installing Programs for FreeKVM" on
page 122.
Web Redirection
It is also possible to use the Web redirection feature to link to a web
configuration or management interface. Choosing Web redirection will create a
link to http://$IP$ in the connection window. If the remote system supports
https, just change the reference to https://$IP$. If there is a specific page or
nonstandard socket requirement, modify the connection accordingly,
e.g.: http://$IP$:8080/specific/filename.htm
Installing Programs for FreeKVM
FreeKVM relies on software installed on the client system to provide access to
the target system. This section is for troubleshooting common issues that may
come up as you use FreeKVM.
• Because the FreeKVM is launched by a Java applet, you must have Java
installed on your Workstation and in your browser.
• Regardless of the software package you use, make sure that the server
has support for that package enabled.
Remote Desktop Protocol
Software Needed
Remote Desktop Client software is provided as part of the standard installation
of Windows for Windows 2000, 2003, and XP systems. Generally, there are no
issues, because it is installed in the windows\system32\ directory.
A Remote Desktop Client program is standard in major Linux distributions and
is available as an open source package that can be installed if it’s not already
present. Make sure the Remote Desktop Client is in your user path on your
Linux/Unix server.
Usage Notes
You can perform applications management and most diagnostics from the
standard Remote Desktop connection. On Windows Server 2003, however,
note that there are actually two different types of connection – one for general
122
Chapter 12
Configuring FreeKVM
access and one to take over the primary VGA data stream.
Some applications may require access to the primary VGA data. Windows
systems prior to Server 2003 provide the VGA facility on the standard data
stream.
To access the primary VGA data stream, use Remote Desktop Client -console.
To enable Remote Desktop on your Windows Server 2003 System, choose
My Computer > Right Click > Properties > Remote > Enable Remote Desktop
on this Computer.
VNC Viewer
Client Software Needed
Windows:
• TightVNC from http://www.tightvnc.com/
• RealVNC software from http://www.realvnc.com/
• UltraVNC from http://www.ultravcn.com/
Linux: vncviewer from the VNC client software package for your distribution.
Make sure that vncviewer is installed into a folder in your standard Windows or
Linux/Unix path. On Windows systems, as a secondary option, you can copy
the vncviewer.exe file to your c:\windows directory.
Usage Notes
Follow the distribution-specific instructions for enabling VNC support on your
Unix or Linux Server.
For secure VNC from Windows desktops, Digi provides an automatic VNC
tunnelling toolkit. The toolkit is included on the Passport CD and is available
from the Digi website http://www.digi.com/support under Digi Passport.
To use the tool (called ssh_vnc.exe) unzip the toolkit and place the files inside
it into a directory in your path. A good default is %WINDIR% (usually this is
C:\Windows).
To use the tool, use User defined protocol, set the program name to ssh_vnc
$IP$:5901 (or whatever socket your VNC application is listening to). Full
documentation for the tool is provided in the release notes included in the zip
file.
Xmanager
Client Software Needed
The Xmanager software is available for a free 30 day evaluation download
from http://www.netsarang.com/download/main.html
Chapter 12
123
Installing Programs for FreeKVM
Usage Notes
Install the client software in a directory in the PATH of the Windows system;
otherwise, you must update path to include the base directory for the
Xmanager software.
Make sure that X Window System is configured to allow for remote
connections from your Client workstation’s IP address.
Full documentation of Xmanager capabilities is included with the evaluation
download.
124
Chapter 12
Rackable® Systems Management Card
Chapter 12
Rackable® Systems Management Card
Introduction
Rackable® Systems manufactures a management card that is built into some
of their servers. It interfaces between the Digi Passport unit and the server’s
serial port. In normal mode, it allows transparent communication between the
Digi Passport unit and the server. After detecting an escape sequence, it
allows you to control functions from the server independently of the main
processor. The controllable functions are listed below:
• Switching power on or off
• Rebooting
• Turning the status LED on or off
• Programming the LCD panel
• Reading the temperature from inside the server
• Setting the power on delay
The Digi Passport unit offers a graphical web based user interface to manage
the Rackable Systems Management Card.
Set up
Setup of the Digi Passport Unit to Support the Rackable Systems Management Card
To set up the serial port to provide access to the Rackable Systems
Management console, do the following:
1. Access the Digi Passport unit’s web interface.
2. Under the Serial Port heading choose Configuration.
3. Choose a port.
4. Choose Host mode configuration.
The Host mode configuration page appears.
5. Set the Host mode to Console server.
6. Set the “Rackable Systems Mgmt Card” support to Enable.
7. Click Save & apply.
Configure Serial Port Communication Settings:
1. Choose Serial port parameters from the menu.
2. Adjust the settings as required. The defaults for the Rackable Systems
Management Card are identical to these of the Digi Passport unit:
Baud rate
9600
Data bits
8
Parity
None
Stop bits
1
Flow control
None
Chapter 13
125
Set up
DTR behavior
3. Click Save & apply.
High when open
Assign a Port Name:
1. Choose port title from the menu.
2. Enter a port title.
3. Click Save & apply.
Accessing the Rackable Systems Management Card from the Digi Passport Unit’s User
Interface
1. Access the Digi Passport unit’s web interface.
2. Under the Serial Port heading choose Connection.
A screen similar to the following appears.
3. Click on the Rackable Server link.
A screen similar to the following appears.
126
Chapter 13
Rackable® Systems Management Card
4. Use the Digi Passport unit’s user interface to perform Rackable Systems
Management Card functions. The following describes attributes of the user
interface controls.
.
Field
Description
Control
Power status
The first column shows the current state.
Three buttons are available to initiate an action to either, power
on, power off or restart the server. Dependant on the current status Power on or Power off is disabled.
Reboot
Reboot the Rackable Server by sending a 500ms reset signal to
the server.
Connect
Spawn the Java Telnet applet or the local Telnet/SSH application
to connect directly to the port.
LED Mgmt
LED
Management
To control the LED in the front of the Rackable Server.
The first columns shows the current status of the LED. Three buttons are available to select the activity of the status LED: turn on,
turn off and blinking. Either of these buttons is disabled.
LCD Mgmt
Chapter 13
Currently
displayed
message
Shows the message that is currently displayed on the LCD display.
Erase
This function clears the LCD display.
The saved message stays saved to flash.
Save
Save currently displayed message to flash memory.
127
Set up
Field
Description
Show saved
LCD message
upon startup
The first columns shows the current status: Yes or No.
This parameter defines which message is displayed upon startup
of the server, either the saved message or the standard: “Rackable Systems Phantom Vx.xx”.
Contrast
Set a contrast for the LCD panel.
The default is 50, the range is 0 – 100.
Phantom
Properties
128
Temperature
Indicates current temperature inside the Rackable Systems Server.
Power delay
Time in seconds before the server starts up after applying power
(0-98 seconds, 99 means no power on delay).
Power sense
The power sense option toggles between sensing server power
on the reset header or on the J7 connector. Most applications will
use the “Reset” option. This option should be set before shipping
from Rackable Systems, but may need to be reset if somehow
changed after shipping.
Communication
settings
Baud Rate
Configure the baud rate used to communicate with the Rackable
Systems Management Card. For this change to become effective
reset or power-cycle the Management card, and be sure to
switch the port settings in the Digi Passport unit’s port settings.
Chapter 13
Configuring Remote Dial-In Access
Chapter 13
Configuring Remote Dial-In Access
Introduction
The Digi Passport unit supports dial-in connections from remote sites for outof-band access. In this configuration, the Digi Passport unit has serial ports
configured for external modems and waits for dial-in connections from remote
sites. If you dial-in using a terminal application, the Digi Passport unit accepts
the connection and displays a menu of available serials ports. In a dial-in
terminal server mode, the Digi Passport unit makes a TCP connection with
either a Telnet or SSH client to a pre-defined server. RawTCP is also an option
for dial-in users.
For more information on the different types of Host mode configuration, see
"Host Mode Configuration" on page 59.
Configuring for Dial-In Modem Access
To configure a serial port for a dial-in modem, enter the values for these fields:
Host mode, Modem init string, and Inactivity timeout. To access the Host mode
configuration screen, do the following:
1. Access the web interface.
2. Under the Serial port heading, choose Configuration.
3. Choose a specific port under Individual port configuration and then choose
Host mode configuration.
4. Select Dial-in modem for the Host mode in the drop down menu.
5. Fill in the appropriate fields as they apply to your configuration.
Chapter 14
129
Configuring for Dial-In Modem Access
- The default modem init string is q1e0s0=2. The init string
sets the modem to quiet mode, echo off, and Auto Answer on two rings.
The modem init string is used for initializing an external modem attached to
the Digi Passport unit’s serial port. See your modem user manual for more
information.
Callback - For security reasons, the callback feature can be activated.
Modem init string
If callback is enabled, the Digi Passport unit does not accept any incoming
calls. After the incoming call is rejected, a callback is initiated to the phone
number configured in the “Dial-in modem callback phone number”.
Modem test - To ensure the proper functionality of the modem, the Digi
Passport unit has the ability to test the modem connection in a configurable
interval.
The modem test allows you to specify a phone number and an interval.
After the system has booted, the interval has elapsed, and the modem is
not in use, the specified dial number is called. The modem trains and
130
Chapter 14
Configuring Remote Dial-In Access
receives a login prompt from the other side (normally another Digi Passport
unit).
If the login-in prompt (login:) is detected the line is disconnected again and
the modem test is considered successful.
Two ports can call each other using this modem test procedure.
Please be aware that the tests will fail if the other modem is in use.
There are multiple ways to review the information about the mode test:
• syslog in the Digi Passport unit:
07-16-2004 12:45:01 > Port #16 - Modem Test started. Calling to 1234444567.
07-16-2004 12:45:22 > Modem connected through Port #15
07-16-2004 12:45:22 > Port #16 - Modem Test succeeded
•
•
Chapter 14
In this example a modem connected to port 16 is calling another
modem connected to port 15.
Any errors occurring are captured in the syslog file as well.
e-mail based notification
The Alert configuration dialog of the port configuration, contains multiple
settings:
The title of the e-mail and the address can be configured.
To be able to configure e-mail notifications, a primary SMTP server has
to be configured under Network > SMTP configuration.
SNMP configuration
It is also possible to receive notifications using SNMP traps.
When using SNMP traps the global settings for IP address, Community
and Version can be used, or specified separately.
131
Adding a PC Modem
The Trap MIB can be downloaded from support.digi.com (select your
product and go to Diagnostics, Utilities and MIBs).
6. Click Save & apply.
Adding a PC Modem
A PC card slot is provided on the front panel of the Digi Passport unit. To install
and configure the PC modem on the Digi Passport unit, do the following.
1. Insert the card into the PC slot located on the front of the device.
2. Access the web interface.
3. From the menu, choose Configuration under the PC card heading.
4. Choose Discover a new card.
The Digi Passport unit searches for a PC card and displays a configuration
menu.
5. Enter the appropriate parameters in the configuration menu.
6. Click Save & apply.
Configuring for Dial-In Terminal Server Access
The host mode Dial-In Terminal Server is identical to the host mode Terminal
Server but allows you to configure a modem init string. In this mode an
incoming modem connection is automatically connected to an IP address.
To configure a serial port for a dial-in terminal server access, enter the values
for these fields: Host mode, Destination IP, Base Port, Protocol, Inactivity
timeout, and Modem init string. To access the Host mode configuration screen,
do the following:
1. Access the web interface.
2. Under the Serial port heading, choose Configuration.
3. Choose a specific port under Individual port configuration and then choose
Host mode configuration.
4. Select Dial-in terminal server for the Host mode from the drop down menu.
5. Fill in the appropriate fields as they apply to your configuration.
The IP address of the system that you will be automatically
connected to when you access the port.
Destination port -´ The TCP port that will be used when the port you
accessed is automatically connected to a system on the network.
Protocol - The protocol that will be used to establish the connection to
Destination IP: port. The options are SSH, RawTCP, and Telnet.
Inactivity timeout - The timeout length ranges from 1 to 3600 seconds; 0 is
unlimited timeout.
Modem init string - Use the default string or enter your own string.
6. Click Save & apply.
Destination IP -
132
Chapter 14
Configuring Remote Dial-In Access
Chapter 14
133
Power Controller
Chapter 14
Power Controller
Introduction
The Power Controller feature allows the administrators of the Digi Passport
unit to use console management to control power functions. Power control
consists of three basic functions: on, off, and reboot (power cycle). There are
two typical scenarios when using a power controller. The simplest scenario is a
non-serial device connected to a power controller (for example, an
environmental sensor controller or a tape backup device). The power
controller is configured and accessed through the Digi Passport unit.
This illustration shows the a power controller configured through the Digi
Passport unit for non-serial devices.
The second scenario is a serial device (such as a router or server) managed
through a port on the Digi Passport unit with its power supply mapped through
the power control feature. After configuration is complete, you need only
reference the console management port on the Digi Passport unit to also
manage power. The Power Controller feature handles the relationship of a
specific outlet to a serial device as if the power supply was also connected to
the same port as the serial device. In other words, you don’t need to see the
physical connection or remember which outlet controls a specific serial device
after configuration - the Digi Passport unit does that for you.
Chapter 15
135
Installing Power Controller
The following illustration shows a Sun server configured through a serial port
connection on the Digi Passport 32.
Installing Power Controller
To connect the Digi RPM power controller to the Digi Passport unit use the
straight-thru cable provided with the Digi RPM unit. Plug one side into the
“Console” port of the Digi RPM unit and the other into any port of the Digi
Passport unit. If you plan to connect multiple power controllers, set up all of
them as described before proceeding. For details on how to configure the Digi
RPM unit for cascading refer to "Cascading Multiple Digi RPM Units" on page
144.
If you are using any other manufacturer of power controllers, please refer to
"About Serial Port Cabling" on page 207 for more information.
Before proceeding, plug the power controller into an appropriate power source
and turn it on.
Note:
The DIP switches on the Digi RPM unit are used for cascading. Make sure that
the dip switches of the first unit are set to off. For more information about
cascading refer to "Cascading Multiple Digi RPM Units" on page 144.
Configuring Power Controller
Only system administrators can add a power controller although authorized
users may reconfigure outlets or serial ports.
Configure the Serial Port Parameters to Match the Power Controller
1. Log in to the Digi Passport unit (username root, password dbps).
2. Click Serial port > Configuration.
3. Select the port number of the serial port you want to connect to the power
controller.
4. Select the Serial port parameters:
Baud rate
9600
Data bits
8
Parity
None
Stop bits
1
Flow control
None
DTR behavior
High when open
5. Click Save & apply.
136
Chapter 15
Power Controller
6. Continue by adding the power controller.
Add the Power Controller
1. Log in to the Digi Passport unit (username root, password dbps).
2. Click Power Controller > Configuration.
3. Select the port number of the serial port you want have connected to the
power controller(s), the manufacturer of the power controller, and the
number of units to be cascaded (1 means that one unit will be connected
(no cascading)).
Note:
The number of cascaded units cannot be changed later, so make sure you have
all power controllers connected before proceeding.
The default title is the manufacturer brand and the port number it is
connected to. You have the ability to change this title in step 5 if needed.
4. Click Add controller.
5. After the controller is detected automatically, you can correct the number of
ports if necessary or edit the port title.
6. Click Save & apply.
7. Continue by setting the alarms and thresholds.
Serial Port info
The P (Power) column allows you to control power of the attached devices, if a
Remote Power Management unit is attached and you have appropriate rights.
The M (Manage) column offers web based management for Windows Server
2003, Remote Power Management units or Rackable Systems Management
Card.
The “# of User” column shows how many users are actually connected to the
port and the username of the read/write user.
If you are conducting a special task through the console port, like BIOS
upgrade and should not be interrupted, you can notify other users by entering
a comment upon connect. This comment is shown here.
8.
Chapter 15
137
Setting Alarms and Thresholds
Setting Alarms and Thresholds
Power Controller allows administrators to set an alert via E-mail notification or
an SNMP trap when environmental conditions exceed specifications.
1. Under Power Controller click Alarms & thresholds.
2. Enter the appropriate parameters. Select the condition(s) for an alert and
enter the information for the alert (E-mail or SNMP trap or select both).
Note:
If multiple power management units are cascaded, the alarm threshold is set for
the sum of all outlets.
Note:
To set up an E-mail alert it is assumed that the mail server has already been set
up. If not, go to "Configuring SMTP Alerts" on page 70. If the SMTP server is not
set up, the E-mail option will not be available.
3. Click Save & apply
4. Continue by configuring the outlets.
138
Chapter 15
Power Controller
Outlet Configuration
The following procedure allows you to setup the power supplied to your device
from the power controller.
1. From Power controller, click Outlets.
2. Click the outlet number to configure.
3. Select the serial port number that controls the device connected to the Digi
Passport unit (if any). If the port number has a title, it will appear.
Note:
If you want to add a title or change the existing title, go to Serial port >
Configuration and select the port number that you want to add or change the title.
Enter the title and click Save & apply. Go back to Power Controller > Configuration
> Title > Outlets and select the outlet you are configuring to continue.
4. If you are not selecting a serial port number, you can modify a user’s
access on this screen. Enter the User Access Control parameters - see
"User Access for Power Controller" on page 140.
5. Click Save to flash and repeat steps 2- 4 for each outlet you want to
configure.
6. Click Save & apply.
Chapter 15
139
User Access for Power Controller
Note:
The screen above shows that serial port one on the Digi Passport unit is
connected to a Sun Server that is supplied power from outlet 1 on the power
controller. In the example above, tomw has access to the power outlets.
7. To select the parameters for the User Access Control, click the User Access
link. You may grant specific users permission to access an outlet or restrict
access for specific users from an outlet. For more information see "User
Access for Power Controller" on page 140.
User Access for Power Controller
The Digi Passport unit can be configured to allow all users or specific users
access to the power controller feature as well as restricting specific users to
the power controller feature. User Access is configured on an outlet by outlet
basis.
Note:
User Access to a serial device that is connected to the power controller in
configured under Serial Port > Configuration > Port # > User Access
Configuring to Allow Specific Users Access
To configure the Digi Passport unit for specific users, you must deselect
<<Everyone’s>> access and add the specific user and access as in the
following steps.
1. Log in to the Digi Passport unit (username root, password dbps)
2. Click Power Controller > Configuration > Outlets > Select the outlet # to
configure.
3. Select the port to configure to the outlet. If it is a non-serial device select
None.
4. Edit the outlet title. If there is a serial port, the port title will appear and
cannot be edited from this screen.
5. Click Save & apply.
140
Chapter 15
Power Controller
6. Under Everyone uncheck the Access type and click Save to flash.
7. Enter the user that will have access and check the Access type.
Note:
Port is access to the port. Monitor is access to sniff. Power is access to the power
management.
8. Click Save to flash. Repeat steps 7 and 8 for additional users.
9. Click Save & apply after all users have been entered.
Note:
The screen above shows outlets 1 & 2 control power to the Sun Server configured
on port 1 of the Digi Passport unit. Outlets 3 and 4 are not serial devices. janl has
been designated the specific user to control outlet # 3.
Configuring to Restrict Specific Users
To restrict specific users, you must select access for << Everyone>> and add
the restricted user by deselecting his or her access.
1. Log in to the Digi Passport unit (username root, password dbps).
2. Click Power Controller > Configuration > Outlets > Select the outlet # to
configure.
3. Select the port to configure to the outlet. If it is a non-serial device select
None.
4. Edit the outlet title. If there is a serial port, the port title will appear and
cannot be edited from this screen.
5. Click Save & apply.
6. Check Everyone and click Save to flash.
Chapter 15
141
Power Controller Management
7. Enter the username that will NOT have access, uncheck the Access types
that are restricted, and click Add.
Note:
Port is access to the port. Monitor is access to sniff. Power is access to the power
management.
8. Click Save to flash and repeat steps 7 and 8 for additional users.
9. When all users have been added Click Save & apply.
Note:
tomw does not have access to Outlet # 4.
Power Controller Management
The Power Controller Management option allows you to change outlet settings
or get a quick update of the power controller status.
1. Under Power Control click Management.
The Power controller management screen gives a quick view of all the power
controllers and the current status of the connection. The Port # and
Manufacturer fields are a link to the specific power controller statistic page,
which displays information for the power controller. If the status is
‘Disconnected’ the links are inactive.
142
Chapter 15
Power Controller
2. Click either the Port # or the power controller title.
The Power controller statistics screen appears to show the Alarm threshold,
Current temp, Circuit breaker condition, RMS voltage, RMS current, and Max
current detected.
The Clear button will reset the Max current detected to 0.0 amps. From this
screen click Outlets.
3. Select the outlet number that you would like to manage.
Note:
The screen below shows that all the outlets are powered On and outlet 3 is
Rebooting, therefore the Backup Tape Device is power cycling.
4. Click Power on, Power off, or Reboot depending on what you want the outlet to do.
Chapter 15
143
Cascading Multiple Digi RPM Units
Cascading Multiple Digi RPM Units
The Digi RPM power controllers can be cascaded when used with the Digi
Passport unit.
The DIP switches on the front panel of the Digi RPM allow configuring unique
identities (ID) to the Digi RPMs so they can be identified. In a cascaded
environment each unit has to be configured to a unique ID.
To cascade the Digi RPM units, connect a serial port of the Digi Passport unit
to the Console Port of the first Digi RPM unit using a straight-thru cable.
Connect the “Cascade” Port of the first Digi RPM unit to the “Console” Port of
the second.
Following an example of two cascaded Digi RPM units connected to a Digi
Passport unit.
Please note that the ID for the first unit is set to 0 and for the second unit it is
set to 1.
The next table shows all possible IDs that can be configured on the Digi RPM.
144
Chapter 15
Power Controller
unit.
Chapter 15
145
Port Clustering
Port Clustering
Chapter 15
Introduction
Port clustering is the ability to coherently manage serial ports across multiple
devices. Digi Passport supports two methods of port clustering, both of which
can be used concurrently.
Master/Slave Clustering
This method allows serial ports on one or multiple slave devices to be
managed from one master device using a single IP address. For instance, the
Digi Passport unit can manage up to 16 slave devices or a maximum 816
serial ports with one Master device. Ports can be configured either collectively
or individually depending on user preference. Each master and slave device is
configured separately; they cannot be configured from one master console.
A secondary IP address can be specified to put all slaves on a private network.
The secondary IP option can be found under Network –> IP configuration.
To set up the Digi Passport unit for port clustering you will need to:
• Configure all the Digi Passport serial ports
• Assign one Digi Passport unit as the master clustering device; all other
Digi Passport units default to slave devices.
• Import slave configuration to the Digi Passport unit’s master device
Remote PC
Master
Ports 7000-7031 - Local
8000-8031 - Slave 1
9000-9031 - Slave 2
Telnet 211.112.67.34 8005
IP 211.112.67.34
Port 5
Server
Chapter 16
Slave 1
192.168.1.102
Slave 2
192.168.1.103
147
Configuring Port Clustering
Configuring Port Clustering
Assigning Master Clustering Mode
To assign a Digi Passport unit as the master cluster device, do the following:
1. Access the Digi Passport unit through the web interface. This Digi Passport
unit needs to be the unit you want as the Master.
2. Under the Clustering heading, choose Configuration.
3. Choose Master from the drop down menu.
Subsequent units will be configured in Slave mode by default.
4. Choose Save & apply.
Configure Slaves to Join a Cluster
Digi Passport units and Digi CM units can be configured as basic slaves
without any additional configuration. Two additional settings, however,
enhance the clustering capability.
Authentication mode -Local authentication is the slave independently
authenticating all port access.
Master authentication is the master performs port authentication. Users do
NOT need to be defined on the slave unit. Password verification will be
done by the master unit.
Update Master on Changes -Automatically updates port name changes, port
settings, and user permission settings to the master unit. Generally, Update
Master on changes should be yes.
148
Chapter 16
Port Clustering
Select the appropriate settings then click Save and apply.
Advanced Clustering Configuration
To refine a cluster environment, use the following parameters for advanced
configuration of a cluster. To access the Advanced menu follow the
proceedure listed below.
1. Select Clustering > Configuration > Master >Save & apply.
2. Select the port number > Enable > Save & apply.
3. Select Advanced from the Clustering >Master mode.
This shows whether the port is enabled or disabled. All ports are
enabled by default.
Slave unit address - IP address of slave.
No. of ports -Number of ports on slave.
Enable -
Chapter 16
149
Configuring Port Clustering
Slave authentication mode - To specify if your database is controlled by the
master unit, or locally by the slaves themselves.
Update Master on Changes -Automatically updates port name changes, port
settings, and user permission settings to the master unit. Generally, Update
Master on changes should be yes.
Connect to slave unit to change configuration - A quick access method to
connect to the slave.
Source port - This is the port number that you would access to get to the
slave on the master unit. The first slave port defaults to 7100 for the port
access menu and the port numbers increase according to the number of
ports on the Digi Passport unit.
Destination port - The destination port is the corresponding port number on
the slave unit. On a 32-port slave unit, the destination port numbers range
from 7001 to 7032.
Protocol - The four options are N/A (not available), SSH, Telnet, and
RawTCP.
Base source port -If you choose not to use AutoConfig, you can set these
ports manually. Base source port is the first port number on a master unit.
By default the base source port on the master unit is 7001. The base
source ports extend the master’s ports via the slave ports. For example,
starting the base source port number with 7101 results in a 32-port unit
being numbered from 7101 to 7082. Port number 7100 is the port access
menu of the slave. If you configure the device manually, the port access
menu must also be configured separately.
Base destination port - The physical port numbers of the slave device.
Note:
150
However, you can change the base source port number to another number and
the rest of the ports on the unit will be sequentially numbered from the base
source port.
Chapter 16
Port Clustering
Chapter 16
151
Clustering Peer-to-peer
Peer to Peer Clustering
Peer to Peer clustering allows multiple Digi Passport units to share information
without requiring one of the units to be the master. This avoids the single point
of failure associated with "centralized system" control -- with Peer to peer
clustering, each unit is capable of initiating connections to ports on any other
unit, avoiding the "what if that unit is unreachable?" problem.
Note: If a Digi Passport unit has Master/Slave clustering configured, it will
report all of its slave ports to the other peer units, however, it is still necessary
for that Digi Passport unit to be operational to reach the Slave ports it controls
Accessing the Cluster Ports
You can connect to the slave port using the web, Telnet or SSH client. You can
access the port access menu or custom menu of each slave device or connect
directly to each slave port.
— Web Access
1. Clustered Ports appear in the WebUI, and can be sorted by Port Title or
Port Number. If there are more ports than will display on the screen, use
the "Move To" pager feature on the upper right of the Port list.
2. To adjust the number of ports that display on a page, See Web Server configuration ON PAGE XXXXX and adjust the "serial ports count on connection page."
— Command Line Access
1. From Ports Menu, choose R to see a list of peered units or S to see a list of
Slave units.
2.
Clustering Peer-to-peer
Master / slave defines one unit as the master and the other units as slaves.
While it is possible to define multiple units as masters for a common set of
slaves, a unit cannot be both a master and a slave at the same time.
Peer to peer clustering allows units to have equal status within a cluster, so
that any unit in the cluster (typically the closest unit to the user) can act as a
master. Peer to peer clustered units can also control slave units as well,
allowing for a more scalable and robust implementation, since if any one unit is
offline, there is no single point of failure to reach the other units.
152
Chapter 16
Port Clustering
Figure 3. Clustering peer-to-peer
Users can access use any peer in peer-to-peer group to access any peer or its
slave units. It extends the limitation of clustering slave units. A master unit can
have up to 48 slave units. 48 peers can join to clustering peer-to-peer group. If
each 48 peer with 48 slave units joins a peer-to-peer group, 2352 units (49 *
48) can be clustered together.
Changes between peered units are updated to the other peers automatically,
even if the peer’s IP address is changed.
Chapter 16
153
Making up a peer_to_peer group
Making up a peer_to_peer group
Peer to peer mode configuration
Figure 4. Peer to peer mode configuration
1. Enable Peer to Peer mode
2. Define the authentication method to be used
3. If Local authentication is used, this peer will continue to authenticate users
locally and independently of other peers.
4. If Peer authentication is used, the first peer contacted will perform the
authentication.
Peered units have to share the same password.
Peer to peer information
Figure 5. Peer to peer information
Peer to peer status:
Not ready: - Peer to peer mode is not active
Not joined: -Peer to peer mode is active but no peers have been defined.
Joining: - Joining peer_to_peer group.
154
Chapter 16
Port Clustering
Joined: -Joined
peer_to_peer group.
Changing peers: -Changing the information of peers in peer_to_peer group
Withdrawing: - Withdrawing from peer_to_peer group.
Withdrawn: - Withdrawn from last peer_to_peer group.
[Refresh] update display of this page
[Join] button: Used to join peer_to_peer group of a designated peer
(requires common password).
[Withdraw] button: Used to withdraw from the current peer_to_peer
group.
[Update] button:Used to get the information of peers which have not
responsed.
Peers list: -The list of the peers that are members of the current
peer_to_peer group.
Join
Figure 6. Join
To join an existing peer_to_peer group , enter the IP address of a member of
that group and click the [Join] button. The joining process will fail if the peer is
not enabled or the password is incorrect.
Figure 6 Peer to peer information of joining peer
Figure 6 shows peer to peer information of a joining peer after joining an
existing group. The list of peers consists of peer number, IP address, peer to
peer authentication method, the link to the web interface of each member of
the group, the link to the port access menu and method, the source port
number range and the count of slave units.
Figure 7. Peer to peer information of the designated peer
Chapter 16
155
Making up a peer_to_peer group
Figure 7 shows peer to peer information of the designated peer.
156
Chapter 16
Port Clustering
Invite peers
Figure 8. Invite peers
To invite peers, enter their IP addresses and click the [Invite] button. Each unit
will be invited to join the peer_to_peer group of the current unit (or a group will
be established if there is no current group. If the remote host is not already part
of a group and its password matches that of the requesting peer, it will join the
local peer to peer group. All existing units in the same peer to peer group will
receive information about the invited hosts.
Chapter 16
157
Making up a peer_to_peer group
158
Chapter 16
Port Clustering
Figure 9. Peer to peer information after inviting peers
Withdraw
Used to withdraw peer_to_peer group.
Remove
Used to remove the peer from the peers list.
Update
Used to get the information of the peers which have not responsed
Connecting to peers
Link to web interface
To link to the web interface of the peer, click the protocol or the source port of
the web port. Please, refer to Figure 9.
Link to port access menu
To connect to the port access menu of the peer, click the protocol or the source
port of the port access menu. Please, refer to Figure 9.
Using the Passport to connect to devices on clustered systems
Ports on clustered systems appear in the Web UI alongside ports from the
local system. The only limitations are that the number of users attached to a
port and the comments field are not available unless you are connected from
the local system for that port. (But this information is still available when you
actually connect to the port)
Chapter 16
159
Connecting to peers
Serial port connection page
Figure 10. Serial port connection page
Figure 10 shows the serial port connection page. If more ports are configured
than will fit on a page, the [--- Move to ---] list box can be used to change the
display to show the rest of the ports that are not displayed on the first page.
Figure 11. Move to list box
By selecting a peer in the Peer list box, users can limit those ports that belong
to the selected peer. Figure 12 shows the Peer: searching option.
Figure 12. Peer list box
The port number consists of the peer number, unit number and port number.
This example shows the first port of slave unit 4 of the second peer.
Connect to a port via connect.asp
Connecting by URL
Users can access to ports using the connect.asp tool on the Passport by using
the following URL construction rules. Connect.asp supports connections by
160
Chapter 16
Port Clustering
Port Title (t=)and by Port Designator (p=). Connections made via the t=
construction will be made to the first port with that title, in the case of duplicate
titles. Connections made via the p= construction will allow explicit connection
to any port.
The p= option can designate ports in the following format:
[R{peer_number}][S{unit_number}][P]port_number where
peer_number is the peer number, unit_number is slave unit number and
port_number is port number.
Ex)
http://192.168.12.8/connect.asp?t=any-unique-port-title (anywhere in the cluster)
http://192.168.12.8/connect.asp?p=1 (This Peer – Port 1)
http://192.168.12.8/connect.asp?p=R2P1 (Peer 2 – Port 1)
http://192.168.12.8/connect.asp?p=R2S0P1 (Peer 2 – Port 1 -- Slave 0 means the master)
http://192.168.12.8/connect.asp?p=R2S4P1 (Peer 2 – Slave unit 4 – Port 1)
Connect to a port via ssh
Users can also access ports using ssh console by including the t= or p=
option.
Ex)
ssh root:[email protected] (where 192.168.12.8 is any
peer)
ssh root:[email protected] (192.168.12.8’s local port 1)
ssh root:[email protected] (Peer 2 port 1)
ssh root:[email protected]
ssh root:[email protected] (Peer 2 Slave 4 port 1)
ssh root:[email protected] (Socket, including socket on a slave via peer)
Custom menu
Users can add the ports of the peers or the slave units of the peers to the
custom menu.
Chapter 16
161
Connecting to peers
162
Chapter 16
System Administration
S y s t em A d mi n i s t ra t i o n
Chapter 16
Introduction
This chapter describes how to perform tasks performed either by root or the
system administrator. These tasks fall under the general heading of system
administration and include firmware upgrades, saving configurations, resetting
the unit to defaults, and disaster recovery procedures.The Digi Passport unit
runs the embedded Hard Hat Linux operating system.
Upgrading the Firmware
Web Interface
The web interface allows you to download the latest firmware version to the
Digi Passport unit. The latest firmware can be found at: http://www.digi.com
under Support, Firmware, Passport. Do the following to upgrade the firmware:
1. Access the web interface.
2. Under the System administration heading, choose Firmware upgrade.
3. Select Local machine or CF card (if configured)
4. Choose the Browse button and locate the firmware download.
5. Choose Upgrade. The Digi Passport unit will automatically reboot when the
upgrade is complete.
Note:
Chapter 17
Do not remove power from the unit while it is updating the firmware. The unit will
reboot automatically when it is done flashing the new firmware.
163
Configuration Management
Configuration Management
Configuration management allows you to save all or parts of your
configuration. You can also establish the time frame to save the configuration
either periodically or 10 minutes after the latest changes. The Digi Passport
unit saves all configurations when the Save & apply button is used or the Apply
changes link is used. These configurations are saved to the loca lDigi
Passport unit in /tmp/cnf directory by default. Manage these configurations by
exporting the files to your location of choice.
1. Click System administration > Configuration management. The
Configuration management screen appears.
2. Under Configuration Export, select the file locations that you wish to save
enter a name and click Export.
Automatically Saving the Configuration
Further down the screen are the options for automatically saving the
configuration either periodically or 10 minutes after the latest changes. The
following list contains the parameter descriptions.
• Automatic backup option
Disable - if you do not want to use an automatic save option
Periodic - used to set the save option per your time frame
10 minutes after last change - as described
• Location
CF card, Primary NFS server, User space, Send via email - options for
where to save the configuration
164
Chapter 17
System Administration
•
Encrypt
Yes - file will be encrypted (.syscm)
No - file will not be encrypted (.tar.gz) in a tar and a gzip’d format
• File Name
The name of the configuration file
• Backup interval
The periodic hourly interval to back up the configuration files.
• Recipient’s email address
The email address to send the configuration file.
To setup the automatic backup option follow the procedure.
1. Select Periodic or 10 minutes after latest change from the drop down
menu.
2. Select the location to save the file.
3. Select Yes or No to encrypt and enter the file name.
4. Enter the number of hours for the backup interval (if periodic)
5. Enter the recipient’s email address to send the configuration file (if the
location is sent via email).
6. Click Save & apply.
Automatically Upgrading the Digi Passport Unit’s Firmware or Configuration using TFTP
The Digi Passport unit supports upgrading the firmware, configuration, or any
other files in the file system using a TFTP-based mechanism.
Chapter 17
165
Automatically Upgrading the Digi Passport Unit’s Firmware or Configuration using TFTP
During boot, the Digi Passport unit can verify a “hash” file and determine if it
needs to download upgrades from the TFTP server.
There are multiple ways to configure the TFTP upgrade function.
DHCP
The DHCP server can automatically assign a TFTP upgrade server and file to
the Digi Passport unit during boot. The options implemented are:
(66) TFTP server address
(67) TFTP filename (this is the filename of the hash file)
To enable DHCP firmware upgrade:
1. Click System administration > Firmware upgrade.
2. Set “Automatic firmware and configuration upgrade at boot time” to Enable.
3. Set “Use DHCP option for remote server and hash file” to Yes.
4. Click Save & apply.
The next time the Digi Passport unit reboots, it will analyze the hash file and
upgrade the firmware, configuration, or other files if required.
Directly Configure the TFTP Server and the Name of the “hash” File
To configure the IP address of the TFTP server and the filename of the hash
file on the Digi Passport unit, follow the steps below:
1. Click System administration > Firmware upgrade.
2. Set “Automatic firmware and configuration upgrade at boot time” to Enable.
3. Set “Use DHCP option for remote server and hash file” to No.
4. Configure the “IP address of remote server “.
5. Configure the “Hash file name".
6. Click Save & apply.
The next time the Digi Passport unit reboots, it will analyze the hash file and
upgrade the firmware, configuration, or other files if required.
If you have trouble with the TFTP upgrade process, please verify that the hash
file and the other files are accessible using TFTP.
The Structure of the Hash File
The hash file is an ASCII configuration file with one line per entry. Each entry
defines one upgrade action.
There are 3 actions defined:
1. Upgrade firmware
2. Upgrade configuration
3. Upgrade any file
4. Execute an application.
The action is the first entry in the line and it also defines the syntax of the line.
Syntax for action 1: firmware upgrade
<image name>,<model name>,<version>
<image name>. specifying the path and the filename of the firmware on the
TFTP server
166
Chapter 17
System Administration
<model name>. specifying the product name especially the port count e.g.
DigiPassport4, DigiPassport8, DigiPassport16, DigiPassport32,
DigiPassport48.
This allows you to have one hash file for different models.
<version>. the version number of the firmware
The Digi Passport unit will download the firmware if the version number
of the running firmware is different than the firmware version in the hash
file (the current firmware version is saved in file /tmp/cnf/version).
Note:
Make sure the firmware version in the hash file matches the firmware version on
the FTP directory, otherwise you will start a continuous upgrade process.
Example: Passport48.img,DigiPassport48,v1.6.0.
After the firmware was upgraded the Digi Passport unit boots again.
Syntax for action 2: configuration upgrade
<image name>,<model name>,<version>
<image name> . specifying the path and the filename of the configuration file on
the TFTP server
<model name>. specifying the product name especially the port count e.g.
DigiCM48, DigiCM32, DigiCM16 or DigiCM8
This allows you to have one hash file for different models.
<version> . the version number of the firmware
The Digi Passport unit will download the configuration if the version in
the hash file is different from the version saved in the file /tmp/cnf/.cnfversion. This file does not exist until you do the first automatic configuration upgrade. It is also deleted if the unit is reset to factory defaults.
If the /tmp/cnf/.cnfversion file does not exist, no download will occur.
The file /tmp/cnf/.cnfversion is a hidden file.
Example: config.tar.gz,DigiPassport48,v1.6.0.
After the firmware configuration is upgraded the Digi Passport unit boots
again.
A sample hash file can be downloaded from: http://cm.digi.com.
Syntax for action 3: file upgrade
<file name>,<options>,<destination>
<file name> . specifying the path and the filename of the file on the TFTP
server
<options>. - F: forced copy (override existing file)
- X: decompress
- Z: unzip
- U: default option for file uploading
<destination> . directory on the Digi Passport unit to place the file
Chapter 17
167
Resetting Factory Defaults
These files are downloaded every time the Digi Passport unit boots and
there is no reboot after downloading.
Example: snmpd.conf,FU,/tmp/cnf.
The file snmpd.conf is copied from the TFTP server and placed into
/tmp/cnf. The file is used as is and the previous version is overwritten.
Syntax for action 4: execute a command
<command> <parameters>
<command> . any application resigin on the Digi Passport unit that is
executalbe by root
<parameter> . all parameters this application requires
Example: touch /tmp/test
Resetting Factory Defaults
There are two ways to reset the unit to the factory defaults. The quickest and
simplest method is to push and hold the hardware factory default reset button
until the Ready light on the front panel goes out. The reset button is located on
the back panel of the unit next to the Ethernet port. The arrow points to the
reset button’s location.
Factory reset button
Digi Passport 32 shown
The alternative method to reset the unit is through the web interface or CLI.
The web interface provides the option of retaining the IP settings. To use the
web interface to reset the Digi Passport unit, do the following:
1. Access the web interface.
2. System administration > Configuration management
3. Under Configuration import select Factory default.
.
4. Select the Configuration factory default options you want to restore from
the checklist.
5. Click Import. The Digi Passport unit will automatically reboot.
From the CLI you can type "factory_reset" this functions the same as the reset
button
The following are the default values when the Digi Passport unit is reset to the
factory defaults.
• Static IP Address: 192.168.161.5
• Port Access Menu IP Address: 192.168.1.100
• Port Access Menu TCP Port Number: 7000
• Serial Port IP Address: 192.168.1.101-
168
Chapter 17
System Administration
•
Serial Port TCP Port Number: 7001-
Setting Date and Time
The Digi Passport unit provides two options for keeping system time. The first
is by using an NTP server and the other is through an internal battery backup.
To configure the Digi Passport unit for date and time, do the following:
1. Access the web interface.
2. System administration > Date and time.
3. To use an NTP server, choose Enable, the NTP server’s IP address, the
Time offset, and the Date and Time fields.
or
To use the internal battery, fill in the Date and Time fields only.
Note:
If you change your time zone, you must go back and reconfigure your time for the
time zone change to be effective.
4. Choose Save & apply.
Chapter 17
169
Configuring a Host Name
Configuring a Host Name
The system administrator can assign a Host name to the Digi Passport unit.
This is often helpful for administration purposes to locate a specific Digi
Passport unit on the network. To assign the Digi Passport unit a device name,
do the following:
1. Access the web interface.
2. System administration > Device name.
3. Enter the name you want to assign the Digi Passport unit.
4. Choose Save & apply.
170
Chapter 17
Command Line Interface
Command Line Interface
Chapter 17
Introduction
The Digi Passport unit runs the embedded Hard Hat Linux operating system.
The command line interface for configuration purposes is accessible only by
the root user. The system administrator has read only privileges from the
command line. By default the root user is connected to the CLI (command line
interface) when accessing the Digi Passport unit through Telnet or SSH. To
gain access to the command prompt, the root user uses the username root
and the root password. The default root password is dbps.
This chapter includes the Linux commands available on the embedded Linux
operating system and the location of files useful to the root user for
administrative purposes.
Note:
The root user should be aware that deleting or corrupting files may prevent the
Digi Passport unit from booting properly. Before editing any files, be sure to back
up your configuration files.
Linux Commands
The purpose of this section is to list the various Linux commands available on
the Digi Passport unit. This is simply a listing of commands and does not detail
what the commands do or give their particular parameters. If you need more
information, see the man pages on a Linux system.
Two commands that are very important for saving and applying changes to the
configuration files are:
• saveconf: The saveconf command saves the configuration files to
flash memory.
• applyconf: The applyconf command immediately applies the
configuration changes.
The configuration files are located in /tmp/cnf directory.
Two system utility menus that are important for accessing and configuring the
Digi Passport unit and the serial ports are the portaccessmenu and
configmenu.
• portaccessmenu: This menu allows the user to access the serial
ports on the Digi Passport unit.
• configmenu: This menu enables the system administrator to configure
the Digi Passport unit. It has essentially the same functionality as the
web interface for configuring a unit with the exception of the ability to
create custom menus.
• portset #: This command allows the user to reset a specific port. It
restarts all processes associated with the port.
• factory_reset: functions identical to the Factory reset button
Chapter 18
171
Important File Locations
Shell and Shell Utilities
sh
ash
bash
echo
sed
env
false
grep
more
which
pwd
File and Disk Utilities
ls
cp
mv
rm
mkdir
rmdir
ln
mknod
chmod
touch
sync
gunzip
gzip
zcat
tar
dd
df
du
find
cat
vi
tail
mkdosfs
mke2fs
e2fsck
fsck
mount
umount
scp
System Utilities
date
free
hostname
sleep
stty
uname
reset
insmod
rmmod
lsmod
modprobe
kill
killall
ps
half
shutdown
poweroff
reboot
telnet
init
useradd
userdel
usermod
whoami
who
id
su
telnet
ftp
Network Utilities
ifconfig
iptables
ssh
ping
route
Important File Locations
The Digi Passport unit has several files that are important for administrative
use. Below is a brief listing of some files that the root user or system
administrator might desire to either monitor or edit.
Default Script
The default script file is executed whenever the Digi Passport unit is booted.
The file is /usr2/rc.user and can be modified with the vi editor. The modified
script becomes effective when the system is rebooted.
Booting Sequence
When the Digi Passport unit boots, it decompresses the /cnf/cnf.tar.gz file to /
tmp/cnf/* and unmounts the /cnf file. If the configuration files are modified in
the /tmp/cnf file and the configuration is saved to flash (saveconf), the unit
mounts the /cnf file and compresses the /tmp/cnf/* to /cnf/cnf.tar.gz.
172
Chapter 18
Command Line Interface
Config Files
All config files are in /tmp/cnf and /tmp/cnf subdirectories. The following table
lists the filenames and a brief description.
File Name
Description
/.ssh
ssh public keys
/bin -active_detect
Key file format <<name>>_auth_key2
Active port detection config
passive_detect
Passive port detection config
rportcon
Remote port config
cluster
./cluster_p2p
Directory for Peer to Peer clustering
cluster.cnf
Basic cluster info
./cluster_p2p/cluster_p2p.cnf
unit#.cnf
/etc -client.pem
Basic slave info
Web Certificate
dhcpd.opt
DHCP certificate file
group
User group info
hostname
Passport host name
hosts
Name resolution hosts file
interfaces
Basic loopback (lo) and ethernet interface
(eth0, eth1) info (Ip, gateway, etc).
ip6tables.save
IPv6 IP access
iptables.save
IPv4 access
krb5.conf
Kerberos config file
nsswitch
Search order for files and DNS
./pam.d
Authorization table directory
passwd
User password file
./ppp resolv.conf
Chapter 18
Basic Peer to Peer cluster info
PPP info directory
DNS info
173
Important File Locations
File Name
Description
server.pem
Stores the private keys when using SSH with
key certification.
shadow
The secure passwd file
snmpd.conf
All snmp info
sshd_config
SSH config file
syslog-ng.conf
Syslog-ng config file
timezone
Timezone file
./xinetd.d
Network services for serial and remote ports
./xinetd.d/master ./xinetd.d/port# ./xinetd.d/telnet menu
./menu
Directory for custom menu xml files
ports
./allports
All ports config dir
./master.cnf
Port access menu config file
./port#
Specific port and remote config dir
./port#/keywords.cnf
Port and remote port keyword alert file
./port#/portinfo.cnf
Port and remote port info file
./rport.default
Remote port config dir
./power
./power/power.cnf
Power controller config
./sys
autobk.cnf
Auto backup
autofwup.cnf
Auto firmware via TFTP
cliauth.cnf
Authentication method via CLI
datetime.cnf
Date/time
modem.cnf
174
Internal modem
./network
Directory with all network config files
ccard.cnf
PC Card
security.cnf
Security profile
Chapter 18
Command Line Interface
File Name
Description
syslog-ng.cnf
Syslog-ng
system.cnf
System log
User Storage Space
The Digi Passport unit comes with 16 megabytes of user storage space. This
storage space can be used to store custom scripts. The location is /usr2.
Custom scripts such as simple commands, are simply dropped into /usr2. If a
file needs to be edited, copy the file into usr2/rc.usr, kill the process, then
restart the process from the new file. Scripts from the user storage may be
created to run during boot after the network is up. The following are some
examples of various ways to create a script stored in the user storage space.
• Saving IP tables options permanently
• Changing radius socket ports
• Limiting root access to the console on Digi Passport products
• Sending a break
Example Scripts
Example Script: -Saving
IP tables options permanently
Add the following command in the '/usr2/rc.user' script file just above "exit
0". Disabling Telnet is just shown as one example.
1. Create a new script file '/usr2/run.user' that includes the commands you
want.
iptables -A INPUT -p tcp --dport 23 -j DROP
2. Run the following command to make the script executable
chmod 755 /usr2/run.user
3. Add the following command in the '/usr2/rc.user' script, just above "exit 0"
ln -s /usr2/run.user /etc/rc.d/rc2.d/S60runuser
4. Reboot
reboot
Note:
If you factory default the unit, the '/usr2/rc.user' script file is moved to '/usr2/
rc.user.old#' and the default rc.user file will be restored.
Example Script: -Changing
radius socket ports
The radius client obtains the radius socket ports to use via the
'/etc/services' file. The client only looks up the lines starting with 'radius'
and 'radacct'.
1. Modify the /etc/services file as follows. Change lines starting with 'radius'
and 'radacct' to the socket numbers you wish. For example:
radius 1645/tcp
Chapter 18
175
Example Scripts
radius 1645/ucp
radacct 1646/tcp
radacct 1646/ucp
2. After editing /etc/services copy it to /usr2
cp /etc/services /usr2
3. Edit /usr2/rc.user and add the following line just above "exit 0":
cp -a /usr2/services /etc/services
4. Reboot
reboot
Note:
If you factory default the unit, the '/usr2/rc.user' script file is moved to '/usr2/
rc.user.old#' and the default rc.user file will be restored.
Example Script: -Limiting
root access to the console on Digi Passport products
(for SSH only)
This prevents root access from any means except physically logging in on
the Digi Passport console.
1. Modify '/etc/inetd.conf' and append -f /usr2/sshd_config to the sshd line.
cp /etc/inetd.conf /usr2/inetd.conf
2. Edit '/etc/ssh/sshd_config'. Change "PermitRootLogin" to no.
cp /etc/ssh/sshd_config /usr2
3. Add the following commands in the '/usr2/rc.user' script. Add these
commands just above "exit 0":
cp -a /usr2/inetd.conf /etc/inetd.conf
while killall inetd 2>/dev/null;
do sleep 5;
done
/usr/sbin/inetd
4. Reboot
reboot
Note:
If you factory default the unit, the '/usr2/rc.user' script file is moved to '/usr2/
rc.user.old#' and the default rc.user file will be restored.
Example Script: -Sending
a break from an existing session with the Digi
Passport unit from a Telnet session
If the Telnet was initiated from a UNIX command line Telnet client. Issuing the
Telnet escape sequence '^]' (control-right_square_bracket) will take you to the
'telnet>' prompt.
telnet>send brk
Note:
Other Telnet clients often have a "send break" option.
From an ssh session -
Type the [tilde-break] which is the default ssh break
characters.
~break
The ssh break can changed from the Web UI or config menu under
Serial ports > Configuration > Host mode configuration > SSH break sequence
Additional binaries or applications can be added to /usr2 such as:
• crontab
176
Chapter 18
Command Line Interface
• netstat
• fuser
To download these utilities go to: http://ftp.digi.com/support/utilities/digicm/
User Administration
Add, edit or delete users with the Digi Passport unit’s command line interface.
•
Add user
Example: useradd -d /tmp [-g groupid] [-s shellprogram] [username]
groupid = Options are: Sys admin, Port admin, or Standard User.
500 = Sys admin
501 = Port admin
502 = Standard User
These are the three types of groups supported by the Digi Passport
unit. You must use one of these.
shellprogram = Options are: CLI (Command Line Interface), Config menu,
Port access menu, or Custom menu.
/bin/bash = CLI
/bin/editconf = Configuration menu
/bin/vts.master = Port access menu
/bin/menu = Custom menu
These are the four types of shells supported by the Digi Passport unit.
You must use one of these four.
• passwd [username]
• saveconf
• applyconf
•
Modify user
Example: usermod -d /tmp [-g groupid] [-s shellprogram] [username]
Syntax is the same as it is for useradd mentioned above.
• saveconf
• applyconf
Delete user
Example: userdel[username]
• saveconf
• applyconf
•
Chapter 18
177
Locator LED Script
The Find Me LED on the Digi Passport 48 can be deactivated and reactivated
with the following file and command.
Note:
All other Digi Passport units have the locator feature without a Find Me LED. To
identify another Digi Passport unit, all the LEDs blink when the feature is activated.
The file and syntax for the locator LED is /bin/blinkled [start|stop]
Example to stop and start locator LEDS [email protected]:~# /bin/blinkled stop
[email protected]:~# /bin/blinkled start
Configuration Menu
Chapter 18
Configuration Menu
Introduction to the Configuration Menu
The configuration menu presents the same functionality in configuring the Digi
Passport unit as does the web interface, excluding the creation of custom
menus. The configuration menu is navigated by using the number
representing the menu item and the ESC key to return to earlier menus. Telnet
to the Digi Passport unit, log in (username root, password dbps) and enter
configmenu to start any configuration. If you log in as admin, the
configuration menu will automatically appear.
Accessing the Configuration Menu
The configuration menu is available through a Telnet or SSH session to the
root user, system administrator, or port administrator. (Port administrator can
only change serial port parameters.) The configuration menu enables the
authorized users to configure the Digi Passport unit with the same functionality
as is available with the web interface. The only functionality missing from the
configuration menu is the ability to create custom menus.
1. Telnet into the Digi Passport unit. The root user, by default, is connected
from a Telnet session to the Linux command line.
2. Enter configmenu at the command prompt. The configuration menu
follows the layout of the web interface.
Choices for the configuration menu are made by selecting the number of a
menu item. The ESC key allows you to move back a menu each time it is
selected. Sometimes only one menu item is presented; however, that single
Chapter 19
179
Configuring SSH
menu item has two or more options that have to be configured.
Configuring SSH
1. Choose Serial Port Configuration and then an individual port number or 0
(zero) for all ports.
The Save
changes option
2. Choose Host mode configuration > Protocol > SSH.
saves changes to
flash memory
only.
3. Use the ESC key to return to the main configuration menu.
4. Choose Exit and apply changes.
180
Chapter 19
Configuration Menu
Adding, Editing, and Removing Users
1. Choose System administration > User administration and then choose an
operation to perform (Add, Remove, or Edit)
2. Configure the user as required.
Adding and Configuring a PC Card
To add a modem card, compact-flash card, wireless LAN card, or a network
card to the Digi Passport unit using the configuration menu, do the following:
1. Access the configuration menu. (1 Network Configuration, 5 Peripherals)
2. Choose PC Card configuration.
3. Configure the card by choosing Change card configuration.
Note:
The system searches for the card and displays information on the product model
number and type of card.
4. Choose Save Changes.
Host Mode Configuration
1. Access the configuration menu.
2. Choose Serial Port Configuration > an individual port number or 0 (zero) for
all ports > Host Mode Configuration.
Chapter 19
181
Port Parameters
3. Enter the desired parameters for each menu item.
Port Parameters
1. Access the configuration menu.
2. Choose Serial Port Configuration > an individual port number or 0 (zero) for
all ports.
3. Enter the desired parameters for each menu item.
Port Access Menu
Another default menu is the Port Access Menu, which is available to all users.
1. Access Configuration menu
2. Select Serial Port Configuration.
3. Select 0 for all ports.
4. Select Port access menu configuration.
182
Chapter 19
Configuration Menu
You can access this menu through a Telnet or SSH session using the IP
address of the Digi Passport unit followed by the port number 7000 as in the
following example:
telnet 192.168.100.200 7000
By default root is connected to the command line interface and the preceding
option allows the root user access to the port access menu.
System Logging
System logging is a two part process. First, the device being used to record
the system logs must be configured. Secondly, system logging must be
configured for the system under System status and log. System logs can be
saved to the Digi Passport unit’s system memory (there is no need to
configure the memory), a compact-flash card, an NFS server, or a SYSLOG
server.
Configure the System Log Device
To configure the compact-flash card for system logging, see "Adding a
Compact-flash Card" on page 33. In Passport, all log messages are sent to
syslog-ng daemon. And 'local 0' facility is only used for system log messages.
And 'local 1' ~ 'local7' facilities can be used for port log.
Each system log logging or port log logging to Syslog server(syslog-ng) can be
set at System logging or Port logging menu, respectively. There is no enable/
disable option for System log to SYSLOG server because it is default function.
And you can also specify facility for each port log from local1 to local7 (local 0
facility is fixed for system log). With this configuration, the management of all
messages sent to Syslog server(syslog-ng) can be configured at SYSLOG-NG
configuration.
Chapter 19
183
System Logging
By default, syslog-ng configuration has internal RAMDISK(/var/log/messages)
logging configuration for system log message(local 0). You can change filter
options for this default configuration by clicking it. Syslog-NG filter
configuration page has all filter options that syslog-ng daemon supports. So if
you add Priority(debug) option to default system log configuration, All local
syslog messages with debug priority will be logged to /var/log/messages
additionally. (Linux kernel and xinetd send some of their message to syslog
with debug priority.)
To send log messages to a remote syslog server,
you should add new destination with "destination=TCP/UDP" and
"Location=IP address of remote server" to syslog-ng configuration.
Procedure for an NFS or SYSLOG Server
1. Access the configuration menu.
2. Choose Network configuration > NFS or SYSLOG server configuration.
3. Disable or enable the server.
Configure System Logging
1. Access the configuration menu.
2. Choose System Status & log > System logging.
3. Enter the desired parameters for the menu items.
So if you add new destination with UDP, local 0 facility and IP address of
remote syslog server to syslog-ng configuration,
then you can receive system log messages from Passport.
Using the flexibility of Syslog-NG configuration menu,
4. you can add 2nd or 3rd remote SYSLOG server or you can group port logs
according to the facility..
184
Chapter 19
Configuration Menu
Configuring SNMP
To configure SNMP from the configuration menu, do the following:
1. Access the configuration menu.
2. Choose Network Configuration > SNMP configuration.
3. Enter the desired parameters for the menu items.
Configuring SMTP
To configure SMTP from the configuration menu, do the following:
1. Access the configuration menu.
2. Choose Network configuration > SMTP configuration.
3. Enter the desired parameters for the menu items.
Configuring Network IP Filtering
The Digi Passport unit offers built-in firewall functionality to limit TCP/IP traffic
to and from certain networks, TCP ports, and interfaces. The functionality
implemented is based on the Linux tool IP tables.
Chapter 19
185
Configuring Network IP Filtering
The next scenario shows that access to the device connected to the Digi
Passport is allowed only on the .1 subnet. The device at 192.168.1.108 can
access the device connected to the Digi Passport because it is in the range
allowed by the IP Filter rule.
Filter IP: 192.168.1.0
Filter Mask: 255.255.255.0
192.168.1.108
192.168.5.10
serial
192.168.5.10
192.168.1.108
It is also possible to enable or disable specific services of the Digi Passport unit
by creating IP Filtering rules:
Telnet console
(TCP/IP port 23)
SSH console
(TCP/IP port 22)
Web configuration
(TCP/IP port 80)
The fields are described next:
Interface -The name of the network interface through which a packet is
received. The name can be one of these values:
eth0:
the default Ethernet interface of the Digi Passport unit
eth1:
the secondary interface added by using a PC card or wireless card
all:
both interfaces
186
Chapter 19
Configuration Menu
Option -
Determines that the rule will be applied to the IP address/Mask
specified or its inverse; that is, the rule will be applied to all except those
specified.
Normal:
applied to the hosts that are included
Invert:
applied to the hosts that are excluded
IP address/Mask - Specifies the host range by entering base host IP address
followed by “/” and subnet mask. The host range can be one of the following
scenarios by changing the value:
• Only one host of a specific IP address
• Hosts on a specific subnet
• Any host
Specified host range
Protocol
Input format
Any host
0.0.0.0/0.0.0.0
192.168.1.120
192.168.1.120/255.255.255.255
192.168.1.1 ~ 192.168.1.254
192.168.1.0/255.255.255.0
192.168.0.1 ~ 192.168.255.254
192.168.0.0/255.255.0.0
192.168.1.1 ~ 192.168.1.126
192.168.1.0/255.255.255.128
192.168.1.129 ~ 192.168.1.254
192.168.1.128/255.255.255.128
- - The protocol that is being accepted on or dropped from the port:
•
•
•
TCP
UDP
ICMP
Port - - A TCP/IP port on the Digi Passport unit that other hosts try to access.
You can specify either one port, using a single value, or a range of ports in this
form : port1:port2
where
port1 defines the lowest port and port2 the highest port.
Chain rule - Determines whether access from the hosts is allowed:
ACCEPT: Access allowed
DROP:
Access not allowed
To add a new IP filtering rule, enter the values for the parameters and click the
Add button on the right side of the table.
To remove a rule, click the Remove button.
After you finish editing the table, save the settings to flash:
• To save your changes, use the Save to flash button.
• To save and apply your changes, use the Save & apply button.
Be aware that you must apply the changes to make them active.
Chapter 19
187
Configuring Network IP Filtering
This screen shows five established IP rules.
This table describes the rules.
Rule
Description
#1
Defines SSH access to the Digi Passport unit (port 22).
• The Normal option specifies that the rule applies to all
addresses listed.
• The rule says to Accept traffic from these addresses for Port 22.
#2
Defines Telnet access to the Digi Passport unit (port23).
• The Invert option specifies that the rule applies to all addresses
except those listed.
• The rule says to Drop traffic from all addresses not listed.
#3, 4, 5
Define access to the Digi Passport unit using HTTP (port 80).
• Rule 3 blocks all traffic.
• Rule 4 allows access from IP address 192.168.1.0.
• Rule 5 allows access from IP address 192.168.2.0.
Allowable Hosts
Input format
Base Host IP Address
Subnet mask
Any host
0.0.0.0
0.0.0.0
192.168.1.120
192.168.1.120
255.255.255.255
192.168.1.1 -
192.168.1.0
255.255.255.0
192.168.0.0
255.255.0.0
192.168.1.0
255.255.255.128
192.168.1.128
255.255.255.128
192.168.1.254
192.168.0.1 192.168.255.254
192.168.1.1 192.168.1.126
192.168.1.129 192.168.1.254
188
Chapter 19
Configuration Menu
Network IP Filtering
To configure the Digi Passport unit for Network IP filtering, do the following:
1. Access the configuration menu.
2. Choose Network configuration > IP filtering.
s
3. Choose a menu item and enter the desired parameters for the menu items.
4. Use the ESC key to return to the main menu.
5. Choose Save changes.
Port IP Filtering
To configure the Digi Passport unit for Port IP filtering, do the following:
1. Access the configuration menu.
2. Choose Serial port configuration.
3. Choose an individual port number or 0 (zero) for all ports > IP filtering.
Chapter 19
189
Sniff Sessions
4. Choose a menu item and enter the desired parameters for the menu items.
5. Use the ESC key when all parameters are entered to return to the main
menu.
6. Choose Save changes.
Sniff Sessions
To configure a port or all ports for sniff users, do the following:
1. Access the configuration menu.
2. Choose Serial port configuration.
3. Choose an individual port number or 0 (zero) for all ports > User access
control.
4. Choose User Access Control.
5. Choose Enable/Disable Sniff Mode.
190
Chapter 19
Configuration Menu
6. Choose a menu item and enter the desired parameters.
7. Use the ESC key when all parameters are entered to return to the main
menu.
8. Choose Save changes.
For information on entering a sniff session, see the next section, "Viewing A
Sniff Session" on page 191.
Viewing A Sniff Session
A sniff user enters a sniff session by starting a Telnet session on a specified
port. In the following example, a sniff user telnets to port 7 of the Digi Passport
unit. From the command prompt enter the following command:
telnet 192.168.100.42 7007
1. Log in and enter your password
2. Enter the port escape sequence.
Chapter 19
191
Sniff Sessions
When sniff users login to a port from a Telnet session, a sniff session menu is
displayed with your permitted options. The first user (with port access rights) to
login to the port is in the main session.
The next user (with port access rights) to enter the port will be given the option
to take over the main session. This user is given the option to take over the
main session by either terminating the first user or switching the first user to
sniff (read only).
Field Descriptions for Sniff Sessions
Escape
Sequence
Ctrl+
m
192
Description of Action
take over main session (read/write)
Occurrence
only presented to users with
read/write access upon entering
a session
Chapter 19
Configuration Menu
Escape
Sequence
Ctrl+
Description of Action
Occurrence
s
enter as a slave session (read only)
only presented to users with
read/write access upon entering
a session
b
send break
not functional for sniff users
l
show last 100 lines of log buffer
must enable logging for this
option
d
disconnect a sniff session
only functional to admin
a
send message to port user(s)
not available to sniff users
r
reboot device using power-switch
only if power management is
available on this port
p
power device on/off
(show only on or off) only if
power management is available
on this port
x
close current connection to port
closes the sniff session
connection
Authentication
1.
2.
3.
4.
Chapter 19
Access the configuration menu.
Choose Serial port configuration.
Choose an individual port number or 0 (zero) for all ports > Authentication.
Choose Authentication type.
193
Upload Server Certificate
5. Use the ESC key to return to the main menu.
6. Choose Save changes.
Upload Server Certificate
To upload your own certificate, you can use one of following two methods,
1. Use Upload Server Certificate menu.
But please note that this menu is displayed only when you run configmenu
on the serial console of the Digi Passport unit. (configmenu run on CLI via
Telnet or SHI will not display this menu)
2. Copy your own server.pem file to /tmp/cnf/ using scp.
Please don't forget to run saveconf command in CLI if you want to keep
this change permanently.
You can use your own certificate for your Digi Passport unit after replacing the
original server.pem on /tmp/cnf/ with your server.pem. The following procedure
is to import an SSL certificate for the HTTPS interface.
OpenSSL (SSLeay) Simple CA Usage - Install Openssl
1. Download latest openssl package
2. Install openssl package
194
Chapter 19
Configuration Menu
# cd /work/
# tar -xvzf openssl-0.9.7c.tar.gz
# cd openssl-0.9.7c
# ./config
# make
# make test
# make install
Make Root CA (Certificate Authority for Self-signed)
1. Edit openssl configuration file
# vi /usr/share/ssl/openssl.cnf
Note:
Modify [req_distinguished_name] section of "openssl.cnf" Please refer to sample
openssl.conf file(openssl.conf.digi). Modify [req_attributes] section of
"openssl.cnf"
challengePassword_min =0
challengePassword_max =0
2.
Make self-signed Root CA(Certificate Authority)
# cd /work/openssl-0.9.7c/
# mkdir CA
# cd CA
# sh /usr/local/ssl/misc/CA.sh -newca
CA certificate filename (or enter to create)
; (Press Enter to use default value)
Making CA certificate ...
; openssl is called here as follow from CA.sh
; openssl req -new -x509 -keyout ./demoCA/private/./cakey.pem \
; -out ./demoCA/./cacert.pem -days 365
3. Use configuration from
/usr/local/ssl/lib/ssleay.cnf
4. Generate a 1024 bit RSA private key.
........++++++
......................++++++
5. Write new private key to './demoCA/private/./cakey.pem'
6. Enter PEM pass phrase:
; CA Password (Enter passsword and remember this)
Verify password - Enter PEM pass phrase: ; CA Password
-----
Note:
The following information will be incorporated into your certificate.
You will enter text for a field call Distinguished Name or a DN. Although there
are many fields, some can be left blank, use a default, or enter ’.’ and the field
will be left blank.
Chapter 19
195
Upload Server Certificate
----- ; CA's Information
Country Name (2 letter code) [AU]: US
State or Province Name (full name) [Your-State]: Minnesota
Locality Name (eg, city) []: Minneapolis
Organization Name (eg, company):
Digi International
Organizational Unit Name (eg, section) [](Enter)
Common Name (eg, YOUR name) []: Bob Alou
Email Address []:(Enter)
#
7.
Verify the CA key file(demoCA/private/cakey.pem) and CA certificate
(demoCA/cacert.pem) is generated
# ls demoCA/
cacert.pem certs crl index.txt newcerts
private serial
# ls demoCA/private
cakey.pem
Making a Certificate Request
To make new certificates, you should make a certificate request first.
1. Enter the following
# cd /work/openssl-0.9.7c/CA
2. Run the following commands:
# openssl genrsa -out key.pem 1024
# openssl req -new -key key.pem -out req.pem
It is assumed that you are using sample configuration file "openssl.conf.digi" )
3. Use configuration from /usr/share/ssl/openssl.cnf
You are about to be asked to enter information that will be incorporated
into your certificate request.
What you are about to enter is what is called a Distinguished Name or a DN.
There are quite a few fields but you can leave some blank
For some fields there will be a default value,
If you enter '.', the field will be left blank.
----Note:
The following information will be incorporated into your certificate.
You will enter text for a field call Distinguished Name or a DN. You may enter a
default or ’.’ to leave the field blank.
----- ; CA's Information
196
Chapter 19
Configuration Menu
Country Name (2 letter code) [AU]: US
State or Province Name (full name) [Your-State]: Minnesota
Locality Name (eg, city) []: Minneapolis
Organization Name (eg, company): Digi International
Organizational Unit Name (eg, section) [](Enter)
Common Name (eg, YOUR name or your server’s hostname) []: Digi Passport
Email Address []:(Enter)
Enter the following 'extra' attributes to be sent with your certificate request
A challenge password []:(Press Enter - Do not enter any other characters)
An optional company name []:(Press Enter - Do not enter any other characters)
Signing a Certificate Request
1.
To sign a certificate request, enter the following:
# cd /work/openssl-0.9.7c/CA
# cp req.pem newreq.pem
# sh /usr/local/ssl/misc/CA.sh -sign
Use configuration from /usr/share/ssl/openssl.cnf
2. Enter PEM pass phrase:
CA Password (Enter CA Password from "Make Root CA
(Certificate Authority for Self-signed)" on page 195
3. Check that the request matches the signature
Signature ok
The Subjects Distinguished Name is as follows
countryName :PRINTABLE:'US'
stateOrProvinceName :PRINTABLE:'Minnesota'
localityName :PRINTABLE:'Minneapolis'
organizationName :PRINTABLE:'Digi International'
commonName :PRINTABLE:'Digi Passport'
Certificate is to be certified until Oct 6 09:39:59 2013 GMT (3653 days)
Sign the certificate? [y/n]:y
1 out of 1 certificate requests certified, commit? [y/n]y
Write out database with 1 new entries
Data Base Updated
Certificate:
Data:
Version: 3 (0x2)
Serial Number: 1 (0x1)
Signature Algorithm: md5WithRSAEncryption
Issuer: C=US, ST= Minnesota, L=Minneapolis, O=Digi International, CN=Digi International
Validity
Not Before: Oct 6 09:39:59 2003 GMT
Not After : Oct 6 09:39:59 2013 GMT
Chapter 19
197
Dial-in Modem Access
Subject: C=US, ST= Minnesota, L=Minneapolis, O=Digi International, CN=Digi Passport
Subject Public Key Info:
Public Key Algorithm: rsaEncryption
RSA Public Key: (1024 bit)
....
-----BEGIN CERTIFICATE----....
-----END CERTIFICATE-----
Signed certificate is in newcert.pem
4. Verify signed certificate(newcert.pem) is generated.
# ls
demoCA key.pem newcert.pem newreq.pem req.pem
Make Certificate for the Digi Passport Unit
1. Removing headings in newcert.pem file
# cd /work/openssl-0.9.7c/CA
# cp newcert.pem server.pem
# vi server.pem
Certificate:
Data:
Version: 3 (0x2)
Serial Number: 1 (0x1)
Signature Algorithm: md5WithRSAEncryption
Issuer: C=US, ST=Minnesota, L=Minneapolis, O=Digi International, CN=Digi Passport
Validity
Not Before: Oct 6 09:39:59 2003 GMT
Not After : Oct 6 09:39:59 2013 GMT
Subject: C=US, ST=Minnesota, L=Minneapolis, O=Digi International, CN=Digi Passport
Subject Public Key Info:
Public Key Algorithm: rsaEncryption
RSA Public Key: (1024 bit)
....
== Removing above lines ===
-----BEGIN CERTIFICATE----....
-----END CERTIFICATE----2. Concatenating key.pem file to server.pem
# cat key.pem >> server.pem
Dial-in Modem Access
Individual serial ports on the Digi Passport unit can be configured for dial-in
198
Chapter 19
modem access. To use dial-in modem mode, an external modem is first
attached to a serial port and then the serial port is configured for dial-in modem
access. In the illustration below, port 7 is configured for a dial-in modem.
To configure a serial port for a dial-in modem, do the following:
1. Access the configuration menu.
2. Choose Serial Port Configuration.
3. Choose an individual port number and then Host Mode Configuration.
4. Select Host mode and then Dial-in modem.
5. Use the ESC key to return to the main menu.
6. Choose Save changes.
Dial-in Terminal Server Access
Individual serial ports on the Digi Passport unit can be configured for a dial-in
terminal server access. To use dial-in terminal server access, an external
modem is first attached to a serial port on the Digi Passport unit and then the
serial port is configured for dial-in terminal server mode. In the illustration
below, port 7 is configured for dial-in terminal server mode.
In terminal server mode, you are connected directly to a server.
To configure a serial port for a dial-in terminal server, do the following:
1. Access the configuration menu.
2. Choose Serial port configuration.
3. Choose an individual port number and then Host Mode Configuration.
4. Choose Dial-in Terminal Server and configure the other configuration
parameters.
5. Use the ESC key to return to the main menu.
6. Choose Save changes.
Clustering
By default clustered slave devices are configured using the Telnet protocol and
port parameters of the following: bps=9600, data bits=8, parity=none, stop
bits=1, flow control=none. When the master device autoconfigures a slave
device, it simply imports the information from the slave unit. If you want other
protocols or other port parameters, you should configure your slave unit first
with those parameters before autoconfiguring.
Before you start this configuration procedure, the slave units should already be
configured unless you want them set to the default values. To set up the Digi
Passport unit for clustering, do the following:
1. Access the configuration menu.
2. Choose Clustering configuration > Unit position.
3. Assign the unit as the master device.
A new screen is displayed.
4. Enter the number 1 for the first slave unit.
5. Choose Enable/Disable unit clustering > Enable.
6. Enter the values for Slave Unit IP, No. of ports, and Port configuration.
Configuration Menu
7. Select the port number to configure or 0 for all ports.
8. Select Enable configuration
9. Select Auto Configuration
10. Choose Exit and apply changes.
Firmware Upgrade
Before upgrading firmware from the configuration menu you should have:
• Downloaded the firmware to a system on the same subnet
• Set up a terminal emulation program that supports Zmodem transfer
protocol
To upgrade the firmware with the configuration menu, do the following:
1. Access the configuration menu.
2. Choose System administration.
3. Choose Firmware upgrade. Enter y for Yes when asked if you want to
upgrade the firmware.
If the firmware upgrade is successful, the Digi Passport unit will reboot
automatically. If a Firmware upgrade failed! Warning appears, do not reboot
the unit but repeat the upgrade process.
Chapter 19
201
Restoring Factory Defaults
Restoring Factory Defaults
You have two choices to restore the unit to its factory defaults. The options are
restoring all factory defaults or restoring all factory defaults except IP settings.
To restore your unit to the factory defaults, do the following:
1. Access the configuration menu.
2. Choose System administration.
3. Select Configuration import.
4. Select Location
5. Select Factory Default.
The system will restore factory defaults, and the unit will automatically reboot.
Note:
Use System Administration to save your configuration in case you need to reload
it later or onto another system. See "Adding and Configuring a PC Card" on page
181 for more information.
Setting Date and Time
Date and time on the Digi Passport unit can either be kept internally or by an
NTP server. To set the parameters for date and time on the Digi Passport unit,
do the following:
1. Access the configuration menu.
2. Choose System administration.
3. Choose Date and Time.
4. Enter the desired parameters.
5. Choose Save changes.
Accessing the Boot Loader Program
The Boot Loader program can be accessed during the boot process. The main
function of the program is to provide a backup means for restoring the
firmware if the Digi Passport unit will no longer boot. It also provides a
202
Chapter 19
Configuration Menu
hardware testing module that detects and tests hardware components on the
unit.
To access the Boot Loader program, do the following:
1. Connect the Ethernet cable from the console port on the rear panel of the
Digi Passport unit to a serial port on a workstation. Use the Ethernet cable
packaged with the Digi Passport unit and attach the DB-9 adapter. The
arrow in the following graphic points to the Console Port.
Console Port
back of Digi Passport 32 shown
2. Set up a terminal emulation program, such as HyperTerminal, using the
following port parameters: bps=9600, data bits=8, parity=none, stop bits=1,
and flow control=none.
3. Turn the power on to the unit.
4. Press ESC within 3 seconds of booting the unit to get Boot Loader menu.
Hardware Test Menu
The Boot Loader program provides a hardware test for detecting and testing
hardware components on the Digi Passport unit. From the Boot Loader menu,
choose the number 3 to access the Hardware test. Options for several
components appear.
Disaster Recovery
The Digi Passport unit provides a disaster recovery procedure in the event the
configuration data is destroyed or corrupted. The Digi Passport unit
automatically restores a corrupted configuration file system to the factory
default settings. However, if the Digi Passport unit fails to boot in spite of being
reset to the factory default settings, the firmware can be restored by using the
Boot Loader program.
To restore the Digi Passport unit to the factory default configuration settings,
you will need to use a TFTP or BOOTP server. To use the Boot Loader
program to flash new firmware, do the following:
1. Connect the console port on the rear panel of the Digi Passport unit to a
serial port on a workstation. Use an Ethernet cable with a DB-9 adapter.
2. Set up a terminal emulation program such as HyperTerminal. Use the
following port parameters: bps=9600, data bits=8, parity=none, stop bits=1,
flow control=none
3. Reboot or power on the Digi Passport unit.
4. Press the ESC key within three seconds of applying power to the device.
The following screen appears.
Chapter 19
203
Accessing the Boot Loader Program
Use the ESC key
to return to an
earlier menu
screen.
5. Choose Firmware upgrade by entering 3.
The following screen appears.
6. Enter the information for the first menu items.
• Protocol: The choices are BOOTP or TFTP
• IP address assigned: Enter the IP address of the Digi Passport unit
• Server’s IP address: The IP address of the BOOTP or TFTP server
• Firmware File Name: The filename for the firmware
Note:
Use the ESC key to back up to earlier menu screens.
7. Choose Start firmware upgrade.
The firmware upgrade will take several minutes to process.
This will factory default the unit.
8. When the upgrade process is complete, choose ESC to return to the main
menu.
9. Choose Exit and boot from flash.
204
Chapter 19
Hardware Information
Hardware Information
Chapter 19
Introduction
This chapter provides information on Digi Passport hardware. Among the
topics covered are the hardware specifications, LED descriptions, pinouts for
the Ethernet cable, pinouts for the cable adapters, and rack mounting
specifications.
Hardware Specifications
Digi Passport 48
Hardware Specifications
Attribute
Chapter 20
Value
AC Powered
Value
DC Powered
Operating temperature
40°F to 120°F (5°C to 50°C)
40°F to 120°F (5°C to 50°C)
Storage temperature
-20°F to 140°F (-29°C to 60°C)
-20°F to 140°F (-29°C to 60°C)
Humidity
10% to 90% non-condensing
10% to 90% non-condensing
Power supply
Internal, 100 -240VAC, 50/60 Hz,
1.2A (max)
Internal, 36 - 72 Vdc, 1.2A (max)
Power consumption
0.37A /120VAC, 45W (typical), 150W
(max)
0.4A /48Vdc, 19W (typical), 40W
(max)
Fuse (internal)
FUSE (Type L) AC250V, 2A
Fuse (Type L) 250V, 5A
Operating system
Linux Hard Hat embedded
Linux Hard Hat embedded
SDRAM
256 megabytes
256 megabytes
Flash memory
16 megabytes
16 megabytes
Dimensions:
unpackaged
17.5” x 10.0” x 1.75”
(44.5 x 25.4 x 4.5 cm)
17.5” x 10.0” x 1.75”
(44.5 x 25.4 x 4.5 cm)
Dimensions:
packaged
20.375” x 15.25” x 4.75 (517.5 mm
387.3 mm x 120.6 mm)
20.375” x 15.25” x 4.75 (517.5 mm
387.3 mm x 120.6 mm)
Weight:
unpackaged
6.5 lbs (2.95 kg)
6.7 lbs (3.05 kg)
Weight: packaged
9.95 lbs (4.51 kg)
10.2 lbs (4.61 kg)
205
Hardware Specifications
Digi Passport 16 and Digi Passport 32
AC Powered
Value
Attribute
DC Powered
Value
Operating temperature
40°F to 120°F (5°C to 50°C)
40°F to 120°F (5°C to 50°C)
Storage temperature
-20°F to 140°F (-29°C to 60°C)
-20°F to 140°F (-29°C to 60°C)
Humidity
10% to 90% non-condensing
10% to 90% non-condensing
Power supply
Internal, 100 -240VAC, 50/60 Hz,
1.2A (max)
Internal, 36 - 72 Vdc, 1.2A (max)
Power consumption
0.1A /120VAC (type), 12W (typical),
40W (max)
Fuse (internal)
FUSE (Type L) AC250V, 2A
Operating system
Linux Hard Hat embedded
Linux Hard Hat embedded
SDRAM
64 megabytes
64 megabytes
Flash memory
8 megabytes
8 megabytes
Dimensions:
unpackaged
17” x 8.5” x 1.75” (431.8 cm x 215.9
cm x 44.5 cm)
17” x 8.5” x 1.75” (431.8 cm x 215.9
cm x 44.5 cm)
Dimensions:
packaged
20.375” x 15.25” x 4.75 (517.5 cm
387.3 cm x 120.6 cm)
20.375” x 15.25” x 4.75 (517.5 cm
387.3 cm x 120.6 cm)
Weight: unpackaged
5.8 lbs (2.63 kilograms)
5.8 lbs (2.63 kilograms)
Weight: packaged
8.6 lbs (3.9 kilograms)
8.6 lbs (3.9 kilograms)
0.25A /48Vdc, 12W (typical),
40W (max)
Digi Passport 8 AC Powered
Attribute
206
Value
Operating temperature
40°F to 120°F (5°C to 50°C)
Storage temperature
-20°F to 140°F (-29°C to 60°C)
Humidity
10% to 90% non-condensing
Power supply
External, 100 - 240VAC, 50/60 Hz, 1.0A (max)
Power consumption
AC input: 0.05A /120VAC, 6W (typical), 12W (max)
DC input: 0.8A/5VAC, 4.5 W (typical), 8W (max)
Operating system
Linux Hard Hat embedded
SDRAM
64 megabytes
Flash memory
8 megabytes
Dimensions
9.5” x 6.25” x 1.25” (241.3 cm 158.75 x 31.75 cm)
Weight
2.5 lbs (1.13 kilograms)
Chapter 20
Hardware Information
LED Indicators
Use the LED indicators to confirm your attachment to the network and that the
Digi Passport unit is able to send and receive data.
LED
System
Ethernet
Serial
port*
Function
Power
On when power is supplied
Ready
On when system is ready to run
PC
On when a PC device is running
100Mbps
On when 100Base-TX connection is detected
LINK
On when connected to an Ethernet network
Act
Blinks when there is activity on the Ethernet port
In use
On when the serial port is ready to run
Rx/Tx
Blinks when there is traffic on the serial port
*Not available on the Digi Passport 48
About Serial Port Cabling
The Digi Passport unit simplifies cabling. The RJ-45 8-pin configuration
matches all SUN and Cisco RJ-45 console port configurations, enabling CAT 5
cabling without pinout concerns. Three DB-25 and one DB-9 adapters come in
the package. A DB-25 male, a DB-25 female, and a DB-9 adapter support
console management applications. A DB-25 male adapter provides a modem
connection. See the cable adapter information that follows later in this chapter.
Note:
The cable length restrictions common to RS-232 cables apply to the Digi Passport
serial cable as well.
Serial Port Pinouts
The Digi Passport unit uses an RJ-45 connector for serial ports. Pin
assignments are listed in the following table.
Pin
Chapter 20
Description
1
CTS
2
DSR
3
RxD
4
GND
5
DCD Note: Inbound signal can
also be used as a second ground.
6
TxD
7
DTR
8
RTS
207
Cable Adapters
Cable Adapters
The Digi Passport unit comes with four cable adapters. The following
illustrations show cable adapter pin outs. Additional adapters can be
purchased from Digi in quantities of 8.
DB-25 Male Console Adapter
(Digi 8-pack reorder P/N 76000672)
Pin #13
Pin #1
Pin #25
DB-25 Male to RJ-45 Connector Pin Assignments
RJ-45
1
CTS
2
DSR
5
DCD
3
DB-25M
Signal
Connected to
4
RTS
Connected to
20
DTR
RxD
Connected to
2
TxD
4
GND
Connected to
7
GND
6
TxD
Connected to
3
RxD
6
DCD
7
DTR
Connected to
8
DSR
5
CTS
8
208
Signal
RTS
Connected to
Chapter 20
Hardware Information
DB-9 Female Console Adapter
(Digi 8-pack reorder P/N 76000671)
Pin #1
Pin #5
Pin #1
Pin #6
Pin #8
DB-9 Female to RJ-45 Pin Assignments
RJ-45
1
CTS
2
DSR
5
DCD
3
DB-9F
Signal
Connected to
7
RTS
Connected to
4
DTR
RxD
Connected to
3
TxD
4
GND
Connected to
5
GND
6
TxD
Connected to
2
RxD
1
DCD
7
DTR
Connected to
6
DSR
8
CTS
8
Chapter 20
Signal
RTS
Connected to
209
Cable Adapters
DB-25 Female Console Adapter
(Digi 8-pack reorder P/N 76000673)
Pin #1
Pin#13
Pin#25
DB-25 Female to RJ-45 Pin Assignments
RJ-45
Signal
DB-25M
Signal
1
CTS
Connected to
4
RTS
2
DSR
5
DCD
Connected to
20
DTR
3
RxD
Connected to
2
TxD
4
GND
Connected to
7
GND
6
TxD
Connected to
3
RxD
6
DCD
7
DTR
Connected to
8
DSR
5
CTS
8
210
RTS
Connected to
Chapter 20
Hardware Information
DB-25 Male Modem Adapter (Digi 8-pack reorder P/N 76000670)
Pin #13
Pin #1
Pin #25
DB-25 Male Modem to RJ-45 Pin Assignment
RJ-45
Chapter 20
Signal
DB-25M
Signal
1
CTS
Connected to
5
CTS
2
DSR
Connected to
6
DSR
3
RxD
Connected to
3
RxD
4
GND
Connected to
7
GND
5
DCD
Connected to
8
DCD
6
TxD
Connected to
2
TxD
7
DTR
Connected to
20
DTR
8
RTS
Connected to
4
RTS
211
Ethernet Pinouts
DB-9 Male Modem Adapter (Digi 8-pack reorder P/N 76000702)
(Available but not included)
Pin #5
Pin #1
Pin #1
Pin #8
Pin #6
DB-9 Male Modem to RJ-45 Pin Assignment
RJ-45
Signal
DB-9M
Signal
1
CTS
Connected to
8
CTS
2
DSR
Connected to
6
DSR
3
RxD
Connected to
2
RxD
4
GND
Connected to
5
GND
5
DCD
Connected to
1
DCD
6
TxD
Connected to
3
TxD
7
DTR
Connected to
4
DTR
8
RTS
Connected to
7
RTS
Ethernet Pinouts
The Digi Passport unit uses a standard Ethernet connector, that is a shielded
and compliant with AT&T 258 specifications.
Pin
212
Description
1
Tx+
2
Tx-
3
Rx+
4
NC
5
NC
6
Rx-
7
NC
8
NC
Chapter 20
Hardware Information
Rack Mounting Installation
Rack shown in illustration is
not included with the Digi
Passport unit.
1. Attach enclosed bracket ears to rack as shown in illustration.
2. Follow safety precautions when placing the Digi Passport unit on the rack.
Rack Mounting Safety Precautions
•
•
•
•
•
•
•
•
Chapter 20
Distribute weight evenly in the rack to avoid overloading.
Ensure proper ventilation with at least 12 inches (30 centimeters) of
clearance on all sides.
Check equipment nameplate ratings before connecting to the supply circuit
to avoid overloads that may damage over-current protection devices and
supply wiring.
Maintain reliable earthing for rack-mounting equipment, especially for
supply connections.
Install equipment in Restricted Access Areas only (dedicated equipment
rooms/closets) in accordance with Articles 110-16, 110-17, and 110-18 of
the National Electrical Code, ANSI/NFPA 70.
Connect equipment to a DC supply source (reliably earthed) that is
electrically isolated from the AC source.
Directly connect the equipment chassis to the DC supply system-grounding
electrode conductor or a bonding jumper from a grounding terminal bar (or
bus) that is connected to the DC supply system grounding electrode
conductor.
Contain equipment that has a connection between the grounded conductor
of the same DC supply circuit, the grounding conductor, and also the point
of grounding of the DC system in the same immediate area. Do not ground
the equipment elsewhere.
213
Rack Mounting Installation
•
•
•
Locate the DC supply source within the same premises as the equipment.
Route away and secure all DC input wiring from sharp edges to prevent
chaffing as well as provide strain relief.
Provide a readily accessible disconnect device and protective device a
fixed wiring for a DC power supply suitable for the specified rated voltage
and current. Disconnect and protective devices to be rated 2A Amps
maximum.
•
This equipment is indoor use and all the communication wirings are limited to inside of the
building."
Rack-mountable
1. Elevated Operating Ambient Temperature – If installed in a closed or multi-unit rack assembly,
the operating ambient temperature of the rack environment may be greater than room ambient.
Therefore, consideration should be given to installing the equipment in a environment
compatible with the manufacturer’s maximum rated ambient temperature (Tmra).
2. Reduced Air Flow – Installation of the equipment in a rack should be such that the amount of
air flow required for safe operation of the equipment is not compromised,
3. Mechanical Loading – Mounting of the equipment in the rack should be such that a hazardous
condition is not achieved due to uneven mechanical loading.
4. Circuit Overloading – Consideration should be given to the connection of the equipment to the
supply circuit and the effect that overloading of circuits might have on over-current protection
and supply wiring. Appropriate consideration of equipment nameplate ratings should be used
when addressing this concern.
5. Reliable Earthing – Reliable earthing of rack-mounted equipment should be maintained.
Particular attention should be given to supply connections other than direct connections to the
branch circuit.
Lithium Battery
"CAUTION"
Danger of explosion if battery is incorrectly replaced.
Replace only with the same or equivalent type recommended by the manufacturer.
(Manufacturer: SONY FUKUSHIMA CORP., Model: CR2032.
Toshiba Battery Co.,Ltd , Model : CR2032 )
DISPOSE OF USED BATTERIES ACCORDING TO THE NATIONAL CODE OR RECYCLING PROGRAM.
214
Chapter 20
Certifications
Certifications
Chapter 20
Safety
•
•
•
US: UL1950
Canada: CSA 22.2 No. 60950
Europe: EN60950 (CB Scheme Report)
Working Inside the Digi Passport Unit
NOTICE: Do not attempt to service the Digi Passport unit yourself, except
when following the instructions from Technical Support personnel. In such a
case, first perform the following actions:
• Turn off the Digi Passport unit.
• Ground yourself by touching an unpainted metal surface at the back of the
equipment before touching anything inside your equipment.
Replacing the Battery
A coin-cell battery maintains date and time information. If you have to
repeatedly reset time and date information after turning on the Digi Passport
unit, replace the battery.
CAUTION: A new battery can explode if it is incorrectly installed. Replace the
3 Volt CR2032 battery only with the same or equivalent type recommended by
the battery manufacturer. Discard used batteries according to the battery
manufacturer’s instructions.
Rack Mounting Installation Considerations
For a rack setup with forced air, the device can run 0-55° C with no extra space
above or below the device (default design of the Digi Passport Rack provides
1/16” = 2mm between devices).
For a rack setup with no forced air, make sure that the air in-between devices
does not get warmer than 55°C by the following measures:
• Providing space between the devices, or
• controlling the ambient temperature on the rack.
• Distribute weight evenly in the rack to avoid overloading.
• Check equipment nameplate ratings before connecting to the supply circuit
to avoid overloads that may damage over-current protection devices and
supply wiring.
• Maintain reliable earthing for rack-mounting equipment, especially for
supply connections.
Chapter 21
215
Safety
Environmental Considerations and Cautions
The following is a list of environmental considerations that will ensure safe and
efficient operation of the Digi Passport unit:
• Do not position the Digi Passport unit near high-powered radio transmitters
or electrical equipment, such as electrical motors or air conditioners.
Interference from electrical equipment can cause intermittent failures.
• Avoid exceeding the maximum cabling distances discussed in the online
cable guide.
• Do not install the Digi Passport unit in areas where condensation, water, or
other liquids may be present. These may cause safety hazards and
equipment failure.
For DC powered equipment:
• Install equipment in Restricted Access Areas only (dedicated equipment
rooms/closets) in accordance with Articles 110-16, 110-17, and 110-18 of
the National Electrical Code, ANSI/NFPA 70.
•
•
•
•
•
•
Connect equipment to a DC supply source (reliably earthed) that is
electrically isolated from the AC source.
Directly connect the equipment chassis to the DC supply system grounding
electrode conductor or a bonding jumper from a grounding terminal bar (or
bus) that is connected to the DC supply system grounding electrode
conductor.
Contain equipment that has a connection between the grounded conductor
of the same DC supply circuit, the grounding conductor, and also the point
of grounding of the DC system in the same immediate area. Do not ground
the equipment elsewhere.
Locate the DC supply source within the same premises as the equipment.
Route away and secure all DC input wiring from sharp edges to prevent
chaffing as well as provide strain relief.
Provide a readily accessible disconnect device and protective device a
fixed wiring for a DC power supply suitable for the specified rated voltage
and current. Disconnect and protective devices to be rated 2A Amps
maximum.
Note:
The Digi Passport unit is intended to connect to networking devices. Do not
attempt connecting to a telephone line.
Safety Instructions
CAUTION: Do not operate the Digi Passport unit with the cover removed.
• To avoid shorting out the Digi Passport unit when disconnecting the
network cable, first unplug the cable from the equipment and then from the
network jack. When reconnecting a network cable to the equipment, first
plug the cable into the network jack and then into the equipment.
• To help prevent electric shock, plug the Digi Passport unit into a properly
grounded power source. The cable is equipped with 3-prong plug to help
ensure proper grounding. Do not use adapter plugs or remove the
216
Chapter 21
Certifications
•
•
•
•
•
grounding prong from the cable. If you have to use an extension cable, use
a 3-wire cable with properly grounded plugs.
To help protect the Digi Passport unit from transients in electrical power,
use a surge suppressor, line conditioner, or a continuous-protected (a
power supply that cannot be interrupted) power supply.
Be sure that nothing rests on the Digi Passport unit cables and that the
cables are not located where they can be stepped on or tripped over.
Do not spill food or liquids on the Digi Passport unit. If it gets wet, contact
Technical Support.
Do not push objects into the openings of the Digi Passport unit. Doing so
can cause fire or electric shock by shorting out interior components.
Keep the Digi Passport unit away from heat sources and do not block
cooling vents.
Emissions
•
•
•
•
•
US: FCC part 15, Class A
Canada: ICES 003 Class A
Europe: EN55022
Japan: VCCI
Australia: AS3548
Immunity
Europe: EN55024:1998
EN61000-3-2: 2000
EN61000-3-3: 1998
Solaris Ready
All Digi Passport products are Solaris Ready certified. This certification
identifies these products have met the stringent testing requirements for
system compatibility, inter operability, ease-of-installation, functionality, and
network interpretability as defined and controlled by Sun Microsystems.
Chapter 21
217
Index
3DES 27
A
accessing a port
web interface 17
ADDP (Advanced Device Discover Protocol) 16
administration See system administration
alerts and notifications
for Power Controller 130
port event handling 65
SMTP alerts 62
SNMP information 62
traps 63
apply all ports settings 51
applyconf 153
assigning IP settings 25
authentication 84
configuration menu 171
configuring 84
local 84
automatic device recognition 23
configuring 49
B
Blowfish 27
Boot Loader program 179
accessing 180
boot sequence 154
C
cable adapters 186
callback 122
Cascading multiple Digi RPM units 136
certifications
Emissions 195
Immunity 195
Safety 193
Solaris Ready 195
command line interface 17
example scripts 156
important file locations 154
Linux commands 153
user administration 158
compact-flash card
adding 31
configuring 32
formatting the card 32
configmenu 16, 153
configuration management 146
configuration menu 16
description 16
Index
using 30
configuring automatic device recognition 49
configuring host mode 54
configuring system logging 41
console server mode 52
custom menus 20, 89
D
date and time
configuration menu 179
setting 151
default menu
port access menu 92
default password 15
defaults See factory defaults
device name
configuring 151
device recognition
configuring 49
dial-in modem
configuring access 121, 128, 175
mode 53
dial-in terminal server 54
configuring access 124
configuring access (configuration menu) 176
Digi Passport
access methods 17
adding and configuring PC cards 31
certifications 193
configuration menu interface 161
configuration methods 15
configuring ports 47
feature overview 13
hardware information 183
port clustering 139
power controller 127
system administration 69
web interface for 16
Digi RPM
cascading multiple units 136
direct port access 20
disaster recovery 180
DTR settings 56
E
emissions certifications 195
EMS support 95
enabling system logging 37
encryption
SSH 27
wireless LAN 34
219
F
N
factory defaults
reset button 150
resetting 150
restoring (configuration menu) 179
values 150
firmware
automatically upgrading 147
upgrade (configuration menu) 178
upgrading 145
network card
adding 32
NTP server 151
H
hardware specifications 183
hardware test menu 180
host mode
configuring (configuration menu) 163
host name configuration 151
HyperTerminal 25
I
immunity certifications 195
inter-character timeout 56
IP filtering
configuring network 73
examples 76
network (configuration menu) 167
port (configuration menu) 168
IP settings 25
L
LDAP 84
LED Indicators 185
Linux
commands 153
default script 154
file and disk utilities 154
Hard Hat 153
network utilities 154
shell utilities 154
system utilities 154
M
menus
adding menu items 91
assigning users 92
creating menu names 90
creating submenu 91
port access menu 164
using the configuration menu 161
Microsoft Server 2003 SAC support 95
modem
adding 124
modem init string 121
modem test 122
220
P
password 15
PC card
adding and configuring (configuration menu) 163
PC cards
compact-flash 31
compatible cards 31
installing and configuring 31
network 32
serial modem 34
wireless LAN 33
port
apply all settings 51
reset 49
port access menu 19, 164
port clustering
assigning master unit 140
configuration menu 177
configuring slave ports 140, 141
Port Escape Menu 21
port logging 43
enabling 38
port parameters 25
configuration menu 164
port title 49
portaccessmenu 153
portreset # 153
Power Controller
overview 127
power controller
alarms and thresholds 130
configuring 128
installing 128
managing 134
protocols 56
RawTCP 56
Telnet 56
R
Rackable Systems MGMT Card 117
set up 117
RADIUS 84
RealPort 47
resetting ports 49
S
SAC support 95
safety certifications 193
saveconf 153
saving and applying changes 22
Index
serial modem
adding 34
serial port parameters 56
serial port pinouts 185
SMTP
alerts 62
configuring 166
sniff session
configuration menu 168
viewing 169
SNMP 62
configuring 63, 166
configuring (configuration menu) 166
managing the SNMP protocol 64
Solaris Ready 195
SSH 20
accessing a port 27
configuring (configuration menu) 162
encryption methods 27
SYSLOG server
enabling 40
system administration
configuration management 146
firmware upgrades 145
host name configuration 151
resetting factory defaults 150
user administration 69
system logging 164
configuration menu 164
configuring device (configuration menu) 165
system logs 43
W
web interface menu 17
WEP 33
wireless LAN card 33
T
TACACS+ 84
Telnet 20
terminal server mode 53
TFTP 147
traps 63
U
user access control
to Power Controller 132
to serial ports 77
user groups 15
user storage space 156
username 15
users
adding 89
adding, editing, and removing 29, 69
admin username and default password 15
administration 69
root username and default password 15, 153
system admin 15
Index
221
PN:(1P) 90000767-88 A
Was this manual useful for you? yes no
Thank you for your participation!