SIMATIC USB-Prommer First Steps in Commissioning


Add to my manuals
14 Pages

advertisement

SIMATIC USB-Prommer First Steps in Commissioning | Manualzz

SIMATIC

USB-Prommer

Description Edition 10/2007

First Steps in Commissioning

Safety Guidelines

This manual contains notices you have to observe in order to ensure your personal safety, as well as to prevent damage to property. The notices referring to your personal safety are highlighted in the manual by a safety alert symbol, notices referring to property damage only have no safety alert symbol. The notices shown below are graded according to the degree of danger.

!

Gefahr indicates that death or severe personal injury will result if proper precautions are not taken.

!

Warnung indicates that death or severe personal injury may result if proper precautions are not taken.

!

Caution with a safety alert symbol indicates that minor personal injury can result if proper precautions are not taken.

Caution without a safety alert symbol indicates that property damage can result if proper precautions are not taken.

Notice indicates that an unintended result or situation can occur if the corresponding notice is not taken into account.

If more than one degree of danger is present, the warning notice representing the highest degree of danger will be used. A notice warning of injury to persons with a safety alert symbol may also include a warning relating to property damage.

Qualified Personnel

The device/system may only be set up and used in conjunction with this documentation. Commissioning and operation of a device/system may only be performed by qualified personnel. Within the context of the safety notices in this documentation qualified persons are defined as persons who are authorized to commission, ground and label devices, systems and circuits in accordance with established safety practices and standards.

Prescribed Usage

Note the following:

!

Warnung

This device and its components may only be used for the applications described in the catalog or the technical description, and only in connection with devices or components from other manufacturers which have been approved or recommended by Siemens.

Correct, reliable operation of the product requires proper transport, storage, positioning and assembly as well as careful operation and maintenance.

Trademarks

All names identified by ® are registered trademarks of the Siemens AG.

The remaining trademarks in this publication may be trademarks whose use by third parties for their own purposes could violate the rights of the owner.

Disclaim of Liability

We have reviewed the contents of this publication to ensure consistency with the hardware and software described. Since variance cannot be precluded entirely, we cannot guarantee full consistency. However, the information in this publication is reviewed regularly and any necessary corrections are included in subsequent editions.

SIEMENS AG

Automation and Drives

Postfach 4848

90437 NÜRNBERG

GERMANY

A5E001134243-01

10/2007

Copyright E Siemens AG 2007

Technical data subject to change

Contents

This description guide offers you step by step instructions on how to install and start the

SIMATIC USB-Prommer.

Features and Functions

Hardware Installation

Software Installation

Connecting to the PC

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Working with the SIMATIC USB-Prommer

Firmware Update

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Troubleshooting

Technical Data

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Further Support and Sales Information

Certificates, Directives and Declarations

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

10

11

8

9

6

7

6

6

3

4

!

Warning

Always follow the safety instructions in this guide, in order to avoid damage to property and personal injury. The notational conventions used to draw your attention to the safety instructions reflect the gravity of the risk involved.

+

Features and Functions

Scope of Delivery

With your SIMATIC USB-Prommer you are supplied with the following:

• one CD, “SIMATIC USB-Prommer”, containing software and documentation

• one SIMATIC S5 programming adapter

• one USB cable

• one plug-in power supply unit with primary-side adapter for EUROPE and USA

• one case

Software Requirements

To work with the SIMATIC USB-Prommer, the following software requirements must be fulfilled:

• the SIMATIC software STEP 5 V7.2 and STEP 7 V5.1+SP2 or later must be installed on the PC.

• the Windows 98SE, Windows Me, Windows 2000, Windows XP, Windows Server 2003 Standard

Edition or Windows Vista operating system must be installed on the PC.

Hardware Requirements

You need a PC with USB interface and CD ROM drive.

SIMATIC USB-Prommer Features

Using the SIMATIC USB Prommer you can read and program both SIMATIC S5 memory cartridges,

SIMATIC memory cards and SIMATIC Micro Memory Cards with the corresponding SIMATIC software package. Bear in mind that in order to program SIMATIC S5 EPROM modules the SIMATIC

S5 programming adapter (included) must be plugged into the PC. The adapter is contained in the scope of delivery.

The SIMATIC USB-Prommer is compatible with USB V1.1 and complies with the specifications for a

“High-Powered” USB device.

The SIMATIC USB-Prommer supports the power-save mode (hibernate mode).

Description SIMATIC USB-Prommer

A5E001134243-01

3

4

Function

The SIMATIC USB-Prommer has a

• a SIMATIC Micro Memory Card interface:

• SIMATIC S5/S7 Memory Card interface: MEM-CARD

The SIMATIC USB Prommer is connected to the PC via the USB port.

If the SIMATIC USB-Prommer is used without plug-in power supply unit, only SIMATIC Micro Memory

Cards can be programmed.

The plug-in power supply unit must be used if you want to program S5/S7 Memory Cards or S5

EPROM modules.

+

Hardware Installation

Backplane

On the backplane of the device you will find the following connections:

• Power supply connector for connection of the plug-in power supply unit.

• A USB interface type B for connecting the PC.

Power supply USB interface

!

Front

On the front of the device you will find the following connections:

• SIMATIC Micro Memory Card interface:

• SIMATIC S5/S7 Memory Card interface:

• Two status LEDs

– BUSY

– POWER

MEM-CARD

LED Busy

LED Power

Description SIMATIC USB-Prommer

A5E001134243-01

LED status indicators

Inscription

BUSY

POWER green green*

Color yellow

Meaning

Lights up when a programming interface is active.

Power supply unit connected. (Device is receiving power from the

USB interface and the power supply unit).

Flashes if a fault occurs.

Only USB cable plugged in. (Power supply from the USB interface).

Flashes if a hardware fault occurs.

* The Power LED does not turn green until the SIMATIC USB-Prommer is connected to an active PC by means of the USB cable, and the power supply unit is plugged in.

If neither the POWER LED nor the BUSY LED lights up even though the USB cable is connected, either the SIMATIC USB-Prommer is in the power-saving mode (Hibernate mode), or the PC to which the device is connected is switched off.

Power supply

The USB cable supolies power from the PC to the SIMATIC USB-Prommer (POWER LED is yellow).

In this mode (without the plug-in power supply unit), the SIMATIC USB-Prommer can program only

SIMATIC Micro Memory Cards (MMCs).

If you intend on programming SIMATIC S7 Memory Cards, SIMATIC S5 EPROM modules, or

SIMATIC S5 Memory Cards, the SIMATIC USB-Prommer must be powered by the plug-in power supply unit as well (POWER LED turns green).

The device is supplied complete with a wide-range plug-in power supply unit with adapters for USA socket outlets, so that it can be used in countries on either continent.

Connecting the Power Supply

Proceed as follows:

1. Plug the DC 12 V supply cable from the power supply unit into the DC 12 V power supply connector on the SIMATIC USB-Prommer.

2. Fit the appropriate power-socket adapter to the plug-in power supply unit. The scope of supply includes an adapter for USA and a standard EURO adapter. The adapter is a push fit on the plug-in power supply unit.

3. Connect the power supply unit to your AC 230 V or AC 115 V mains power socket.

Notice

When the device is connected correctly, the green POWER LED on the SIMATIC USB-Prommer lights up. If the contacts of the power supply connector are dirty, we cannot guarantee that the prommer will function without errors occurring. The LEDs do not light up if the USB cable has not been connected to the SIMATIC USB-Prommer and the PC (which must be ON).

!

Warning

Use only the plug-in power supply unit supplied with the SIMATIC USB-Prommer to connect it to an external power supply.

Caution

For the operation of the SIMATIC USB-Prommer a power supply with limited performance

(USA/Canada: NEC Class 2) is required. The supplied plug fullfills the requirements.

Description SIMATIC USB-Prommer

A5E001134243-01

5

+

Software Installation

Setup runs the installation of the SIMATIC USB-Prommer software automatically after you insert the CD.

If the autorun function is disabled, proceed as follows:

1. Place the SIMATIC USB-Prommer CD supplied with the product in your PCs CD-ROM drive.

2. Open the root directory of this drive.

3. Double-click “setup.exe” to run Setup.

Setup is menu controlled. Please note the readme file in the root directory on the CD for information on the installation and use of your SIMATIC USB-Prommer software.

+

Connecting to the PC

1. Plug the USB cable included with the prommer into the USB interface of your PC.

2. Plug the other end of the USB cable into the USB port on the SIMATIC USB-Prommer.

3. When you use the SIMATIC USB-Prommer for the first time, you have to open the “Memory Card

Parameter Assignment” panel in the Control Panel to set the programming interface to “External prommer” at the connection “USB”.

When you select the “Detect USB prommer automatically” setting, the SIMATIC USB-Prommer is automatically recognized when connected to the PC.

Notice

Use only the USB cable provided for the purpose to connect the SIMATIC USB-Prommer to the PC.

+

Working with the SIMATIC USB-Prommer

Requirement: The SIMATIC USB-Prommer is connected to your PC as described above.

1. Plug the memory medium in question:

– Micro Memory Cards to the Micro Memory Card interface

– SIMATIC S5/S7 Memory-Cards to the interface MEM-CARD

– S5 EPROM/EEPROM modules with the help of the SIMATIC S5 programming adapter to the interface MEM-CARD

2. Connect the plug-in power supply unit as well if you intend programming S5 EPROM modules or

S5/S7 Memory Cards.

3. Start the SIMATIC STEP 7 software or the SIMATIC STEP 5 software.

4. Make sure that the programming interface of your SIMATIC software in the “Memory Card Parameter Assignment” panel is set to the “External prommer” at the connection “USB”.

5. Program the memory module.

6. Unplug the memory module from the interface when programming is completed.

Notice

While programming is in process the LED BUSY lights up.

Do not unplug the memory module, the USB cable or the plug-in power supply unit while programming is in progress.

6 Description SIMATIC USB-Prommer

A5E001134243-01

!

Warning

Simultaneous operation with SIMATIC S5 cartridges, SIMATIC Memory Cards and SIMATIC Micro

Memory Cards is not possible. If SIMATIC Micro Memory Cards and SIMATIC S5 or S7 Memory

Cards are inserted at the same time, the SIMATIC S5/S7 Memory Cards take priority.

+

Firmware Update

The firmware of the SIMATIC USB-Prommer can be updated later if, for example, function expansions require modified firmware.

The procedure for updating the firmware is as follows:

• The latest firmware updates and the firmware update tool are available in the Internet at the following URL: http://www.siemens.com/automation/support&support

• Use ”USB Prommer” as your search term in Product Support.

• Download the self-extracting .exe file of the firmware and firmware update tool to your PC.

• Extract the files to a local drive and then update the firmware on your SIMATIC USB-Prommer by following the firmware update tool instructions.

• Please read the readme file in the firmware update tool catalog. You will find notes on how to install and use the new firmware there.

Description SIMATIC USB-Prommer

A5E001134243-01

7

+

Troubleshooting

Some faults are easily rectified as follows:

Fault/Cause

Power LED does not turn yellow

• USB cable not connected

• PC is switched off

• PC and SIMATIC USB-Prommer are in power-saving mode (Hibernate mode)

• SIMATIC USB-Prommer not recognized by PC

• SIMATIC Memory Cards and SIMATIC Micro

Memory Cards cannot be programmed

• A hardware fault has occurred

Power LED does not turn green

• USB cable not connected

• Plug-in power supply unit not plugged in or defective.

POWER LED flashes continuously

• A hardware fault has occurred.

Remedy

• Connect the USB cable.

• Switch on the PC

• Permissible operating mode

• Install driver

• Check the version of the SIMATIC STEP 7 software

• Contact the Customer Support or your Siemens contact person.

• Connect the USB cable.

• Connect or replace the plug-in power supply unit.

• If the POWER LED on the device continues to flash after USB cable and power supply unit have been disconnected and reconnected a number of times, the device is defective and must be replaced.

Contact the Customer Support or your Siemens contact person.

8 Description SIMATIC USB-Prommer

A5E001134243-01

+

Technical Data

Power supply unit

Type number

Supply voltage

Frequency of the supply voltage

Max. power consumption

Max. current output

Primary Adapter EURO

Primary Adapter USA

SIMATIC USB-Prommer

Order no.

Dimensions

Weight

Supply voltage

Max. power consumption

Safety

FW75550/12

AC 100 – 240 V (+10%, -15%)

50/60 Hz (47 to 63 Hz)

15 W

DC 12 V, 1.25 A

EURO standard plug to VDE 0620, Part 101 or IEC 83/C5

USA plug, to ANSI C73.10 or IEC 8/AI-15

6ES7792-0AA00-0XA0 approx. 172 x 121 x 40 mm approx. 400g

DC 12 V, 1.25A

15 W

Protection class

Safety requirements

Protection class I to VDE 0106 Part 1:(IEC 60536)

IEC 60950 equivalent to DIN VDE 0805, equivalent to EN 60950

Safe isolation between line supply and secondary side by plug-in power supply unit

Electromagnetic compatibility (EMC)

Emitted interference limit class

Immunity to line-borne interference on supply lines

Limit class B to EN55022

± 2 kV

± 1 kV

± 2 kV

Immunity on signal lines (on signal lines) ± 1 kV

± 2 kV

(to IEC 61000-4-4:; Burst)

(to IEC 61000-4-5:; Surge symm)

(to IEC 61000-4-5:; Surge asymm)

(to IEC 61000-4-4:; Burst; length < 3m)

(to IEC 61000-4-4:; Burst; length > 3m)

Immunity to electrostatic discharge

(ESD)

Immunity to high-frequency radiation

RF current

Magnetic field

Ambient conditions

±

±

4 kV, contact discharge

8 kV, air discharge

(to IEC 61000-4-3)

(to IEC 61000-4-2)

(to IEC 61000-4-2)

10 V/m 80-1000 MHz and 1,4 – 2 GHz, 80% AM 1kHz

1 V/m 2 –2.7 GHz, 80% AM 1kHz (to IEC 61000-4-3)

10 V 10 kHz – 80 MHz 80 % AM 1 kHz

(to IEC 61000-4-6)

30 A/m 50 Hz (to IEC 61000-4-8)

Temperature

– Operation

– Storage/transport

Relative humidity

– Operation

– Storage/transport tested to DIN EN 60068-2-2, DIN IEC 60068-2-1,

+5 _C to +40 _C, temperature change max. 10 K/h

-20 _C to +60 _C, temperature change max. 20 K/h tested to DIN IEC 60068-2-3, DIN IEC 60068-2-30, DIN IEC

60068-2-14

5 % to 80 % at 25 _C (no condensation)

5 % to 95 % at 25 _C (no condensation)

Mechanical ambient conditions

Oscillations (Vibration)

– Operation

– Storage/transport

Shock resistance (shock)

– Operation

– Storage/transport tested to DIN IEC 60068-2-6

10 to 58 Hz: amplitude 0.075 mm, 58 to 500 Hz: acceleration tested to DIN IEC 60068–2–27 and DIN IEC 60068–2–29

50 m/s, 30 ms, 100 shocks

250 m/s, 6 ms, 1000 shocks

9.8 m/s

5 to 9 Hz: amplitude 3.5 mm, 9 to 500 Hz: acceleration 9.8 m/s

Description SIMATIC USB-Prommer

A5E001134243-01

9

+

Further Support and Sales Information

Further Support

If you have further questions on how to use the SIMATIC USB-Prommer, please contact your Siemens representative or the SIMATIC Hotline.

You will find your contact person at: http://www.siemens.com/automation/partner

You will find a guide to the technical documentation offered for the individual SIMATIC-

Products and Systems here at: http://www.siemens.com/simatic-tech-doku-portal

The online catalog and order system is found under: http://mall.automation.siemens.com

Training Centers

Siemens offers a number of training courses to familiarize you with the SIMATIC S7 automation system. Please contact your regional training center or our central training center in D 90327 Nuremberg.

Internet: http://www.sitrain.com

Technical Support

You can reach the Technical Suport for all A&D products

• Via the Web formula for the Support Request http://www.siemens.com/automation/support-request

• By e-mail: [email protected]

• Phone: + 49 180 5050 222

• Fax: + 49 180 5050 223

Additional information about our Technical Support can be found on the Internet pages: http://www.siemens.com/automation/service.

Service & Support on the Internet

In addition to our documentation, we offer our Know-how online on the internet at: http://www.siemens.com/automation/service&support.

There you will find the following:

• The newsletter, which constantly provides you with up-to-date information on your products.

• The right documents via our Search function in Service & Support.

• A forum, where users and experts from all over the world exchange their experiences.

• Your local representative for Automation & Drives.

• Information on field service, repairs, spare parts and more under “Services”.

10 Description SIMATIC USB-Prommer

A5E001134243-01

+

Certificates, Directives and Declarations

Notes on the CE Symbol

The following applies to the SIMATIC product described in this description:

EMC Directive

In accordance with the EU Directive 89/336/EEC “Electromagnetic Compatibility.” In accordance with the CE label for this product, the following areas of application are relevant:

Application area

Domestic, business and commercial areas, as well as small businesses

Industrial area

Requirements

Emitted Interference Immunity

EN 61000–6–3: 2001 EN 61000–6–1: 2001

EN 61000–6–4: 2001 EN 61000–6–2: 2005

In addition, the EN 61000–3–2:2000 (harmonic currents) and EN 61000-3-3:2001 (voltage fluctuation and flicker) have been fulfilled.

Low-Voltage Directive

This product complies with the requirements of the EU Directive 2006/95/EEC “Low-Voltage

Directive.” Conformance with this standard has been verified according to EN 60950–1:2001

+A11:2004.

Declaration of Conformity

The EU declarations of conformity and the relevant documentation are held at the disposal of the competent authorities at the address below:

Siemens Aktiengesellschaft

Bereich Automation and Drives

A&D AS RD ST Type Test

Postfach 1963

D-92209 Amberg

Germany

Phone: +49 9621 80 3283

Fax: +49 9621 80 3278

Observing the Installation Guidelines

The installation guidelines and safety instructions specified in this description have to be observed during startup and operation.

Connecting I/Os

The requirements regarding immunity (EN61000–6–2:2005) are met when you connect a PC suitable for an industrial environment.

Description SIMATIC USB-Prommer

A5E001134243-01

11

Approvals for the USA, Canada and Australia

Product safety

One of the following markings on a device is indicative of the corresponding approval:

C US

Underwriters Laboratories (UL) to standard UL 1950 (I.T.E) or to UL508 (IND.CONT.EQ)

Underwriters Laboratories (UL) to Standard UL 60950–1, Report E11 5352 and

Canadian Standard C22 2 no 60950–1 (I T E) or to UL508 and C22 2 no 142

(IND.CONT.EQ)

Canadian Standard Association (CSA) to standard C22.2. No. 950 (LR 81690) or to

C22.2 No. 142 (LR 63533)

12 Description SIMATIC USB-Prommer

A5E001134243-01

EMC

USA

Federal Communications Commission

Radio Frequency Interference Statement

This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense.

Shielded Cables

Shielded cables must be used with this equipment to maintain compliance with FCC regulations.

Modifications

Changes or modifications not expressly approved by the manufacturer could void the user’s authority to operate the equipment.

Conditions of Operations

This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.

Canada

Canadian Notice

This Class B digital apparatus complies with Canadian ICES-003.

Avis Canadien

Cet appareil numérique de la classe B est conforme à la norme NMB-003 du Canada.

Australia

This product meets the requirements of the AS/NZS CISPR 22 norm.

Description SIMATIC USB-Prommer

A5E001134243-01

13

14 Description SIMATIC USB-Prommer

A5E001134243-01

advertisement

Was this manual useful for you? Yes No
Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project

Related manuals

advertisement