PARADOX 1686H User manual

Add to my manuals
44 Pages

advertisement

PARADOX 1686H User manual | Manualzz
10-Zone Spectra LED Keypads
1686H
1686V
User’s Guide
TABLE OF CONTENTS
Introduction ................................................................... 5
Basic Operation............................................................. 6
Auditory Feedback ................................................................. 6
Keypad Indicator Lights ......................................................... 8
Zone Display .......................................................................... 8
Alarm Memory Display .......................................................... 8
Trouble Display...................................................................... 9
Partitioning............................................................................ 13
Programming Access Codes ...................................... 14
System Master Code (Default: 123456) ...............................
Master Codes .......................................................................
Duress Code.........................................................................
Programming Access Codes ................................................
14
14
15
15
Arming & Disarming..................................................... 17
Exit Delay .............................................................................
Disarming & Deactivating an Alarm......................................
Regular Arming.....................................................................
Stay Arming..........................................................................
Force Arming ........................................................................
Manual Bypass Programming ..............................................
One-Touch Arming ...............................................................
Keyswitch Arming.................................................................
Auto-Arming..........................................................................
17
17
18
19
20
21
23
24
25
Additional Features...................................................... 27
Programming Chime Zones .................................................. 27
Keypad Muting...................................................................... 27
Panic Alarms ........................................................................
Program Time (clock) ...........................................................
PGM Button (Programmable Outputs) .................................
Quick Function Keys.............................................................
Keypad Backlight..................................................................
28
28
29
29
30
Fire Alarms.................................................................... 31
Testing & Maintenance ................................................ 35
System Checklist.......................................................... 36
Appendix A ................................................................... 41
1.0 INTRODUCTION
Thank you for selecting the Spectra Security System
from Paradox Security Systems. The Spectra Security
System will give you peace of mind by providing reliable
security protection. Although, it can do much more than
that. The Spectra System can realize your dreams of home
automation such as controlling garage doors, lights,
heating, temperature and much more. Consult your
installer to take full advantage of your Spectra system’s
capabilities.
This advanced technology security system provides you
with reliable security protection and powerful features that
anyone can use without memorizing complex and
confusing codes. The system consists of the Spectra
Control Panel, one or more Spectra Keypads, various input
devices (i.e. motion detectors, door contacts, etc.) and
various output devices (i.e. bells, sirens, lights, etc.).
The elegant and user-friendly Spectra 1686H and 1686V
LED Keypads allow you to easily access your security
system's functions and provide you with an easy-tounderstand display of your security system's alarm and
operational status. All the actions performed in your
security system will be executed and displayed through the
keypad. Therefore, before using your security system, we
highly recommend you read this manual carefully and have
your installer explain basic system operation to you.
Spectra LED Keypads 5
2.0 BASIC OPERATION
Both the Spectra 1686H and 1686V LED Keypads
function and display information the same way. The
following sections provide you with an excellent
introduction to the buttons and indicator lights on your
keypad.
Many of the features in your system must be enabled by
the installer. If the feature is not programmed, the
keypad will emit a “REJECT ION BEEP ” and the action will
be cancelled. Refer to “System Checklist” in section 8.0
for details.
2.1 AU DI T OR Y F EED B A C K
When you enter information on the keypad, it will guide you
with beep tones that communicate acceptance or rejection
of your entries. You should be familiar with these two
keypad beep tones:
Confirmation Beep: When an operation (i.e. arming/
disarming) is successfully entered on the keypad or when
the system switches to a new status/mode, the keypad
produces an intermittent beep tone (“BEEP -BEEP -BEEP BEEP ”).
Rejection Beep: When the system reverts to previous
status or when an operation is incorrectly entered on the
keypad, it will emit a continuous beep tone (“BEEEEEEEEP ”).
6 User’s Guide
Figure 2-1: Overview of the 1686V LED Keypad
AC L ED (orange):
ON = AC power present
OFF = Power failure
Partition 2
READY LED (green):
ON = Zones are closed
OFF = Z one(s) opened or armed
F LASHING = Exit Delay
Partition 1
ARM L EDs (red):
ON = Partition Regular or Forced armed
OFF = Partition disarmed
F LASHING = Partition Stay or Instant armed
FAST FLASHING = Partition in alarm
PGM Button :
Press and hold for 3 seconds
to activate a PGM (i.e. garage
door)
Trou ble Display
Alarm Mem ory Disp lay
Bypass Programmin g
Z one Display:
Buttons [1] to [10] correspond to
zones 1 to 10 respectively. When
the buttons are illuminated, the
zones are open.
1686V LED Keypad
To re-enter data, exit the current mode or cancel an action.
To save and exit.
Spectra LED Keypads 7
2.2 KEY PAD IND IC A T OR L IGH T S
All Spectra LED Keypads include colored lights which
convey the current status of your system. As explained in
Figure 2-1 the state of each light represents a specific
condition in your system.
2.3 ZON E DIS PL A Y
The numerical buttons on the 1686V/H Keypads are
designed to communicate the status of the zones in your
system. Each button corresponds to a zone in your system.
If a button’s light is off (extinguished), the corresponding
zone is closed. If a button’s light is on (illuminated), the
corresponding zone is open (i.e. open door, movement
detected, etc.).
2.4 AL A RM MEM OR Y DI SPL A Y
If an alarm has occurred on a zone, the [MEM] button will
illuminate. All zones where alarms occurred will be stored
in memory. After disarming the system, press the [MEM]
button to illuminate the buttons corresponding to the zones
that were in alarm (see Zone Display in section 2.3). To exit
the Alarm Memory Display, press [CL EAR] button. The
system will erase the contents of the Alarm Memory every
time the system is armed.
8 User’s Guide
2.5 TR OU B L E DIS PL A Y
Your alarm system continuously monitors fourteen possible
trouble conditions. Most of these trouble conditions can be
reported directly to your security company. When a trouble
condition occurs, [TB L] will illuminate.
The keypad can be programmed to emit a “BEEP ” every
5 seconds whenever a new trouble condition has
occurred. Press the [TBL] button to stop the “Trouble
Beep”.
How Do I Access the Trouble Display?
1) Press the [TBL] button
The [ TBL ] button will flash and any numbers corresponding to
an existing trouble condition will illuminate.
2) Read the corresponding explanation of the trouble
from the Trouble List. If no repair instructions are
given, contact your Security Company for repairs.
3) Press the [CL EA R] button to exit
We strongly suggest that you inform your
Security Company of the trouble and allow them
to service your system.
Spectra LED Keypads 9
Trouble List
2.5.1 No or Low Battery Trouble [1]
When the [1] button illuminates, the backup battery is
disconnected or the battery voltage is getting low.
2.5.2 Wireless Transmitter Battery Low [2]
When the [2] button illuminates, the battery voltage in one
or more Wireless Transmitters is getting low. Also, the
device’s yellow light will flash.
2.5.3 Power Failure [3]
When the [3] button illuminates, the system has detected a
loss of AC power. This trouble usually occurs during a
power failure. If a power failure is not occurring in your
establishment and this trouble appears, contact your
Security Company for service.
2.5.4 Bell/PGM2 Disconnected Trouble [4]
When the [4] button illuminates, the bell, siren, or any
device connected to the PGM2 is no longer connected to
your alarm system.
2.5.5 Bell Current Failure [5]
During an alarm, the bell output, which uses a fuseless
circuit, will automatically shut down if the current exceeds
its limits. If this occurs, the [5] button will illuminate. When
the system is disarmed, the current is cut from the bell
output and the Trouble warning may extinguish, but the
Trouble may re-occur during the next alarm if the situation
is not corrected.
10 U ser’s Guide
2.5.6 Auxiliary Current Failure [6]
The auxiliary output, which supplies power to your alarm
system’s accessories, uses a fuseless circuit to protect the
power supply against current overload and automatically
shuts down if the current exceeds 1.1A. If this occurs, the
[6] button will illuminate.
2.5.7 Communication Failure [7]
If your alarm system is monitored and it could not
communicate with the Security Company, the [7] button will
illuminate.
2.5.8 Timer Loss [8]
When the [8] button illuminates, your alarm system’s clock
must be re-programmed. This is the only trouble that we
recommend that you correct.
To re-program the clock press the [8] button after Step 2
from the Trouble Display (see “How Do I Access the
Trouble Display?” at the beginning of section 2.3) and enter
the current time using the 24-hour clock (i.e. 8:30PM =
20:30). Also, refer to section 5.4 and Appendix A.
2.5.9 Tamper/Zone Wiring Failure [9]
When the [9] button illuminates, a wiring problem is
occurring on one or more zones.
To view which zones are experiencing trouble, press
the [9] button after Step 2 from the Trouble Display (see
“How Do I Access the Trouble Display?” at the beginning
of section 2.3) (see Zone Display: section 2.3).
Spectra LED Keypads 11
2.5.10 Telephone Line Monitoring Failure [10]
With button [10] illuminated, the presence of a telephone
line has not been detected for more than 30 seconds.
2.5.11 Fire Zone Trouble [STAY ]
When the [STAY ] button illuminates, a wiring problem on
the fire zone is occurring.
2.5.12 Module Loss [BYP ]
When a module is no longer communicating with your
system, the [B YP ] button illuminates.
2.5.13 Wireless Transmitter Supervision Loss [MEM]
When a wireless transmitter is no longer communicating
with its receiver or its batteries are disconnected, [ MEM]
illuminates.
.
To view on which zones the Wireless Transmitters are
experiencing trouble, press the [MEM] button after Step 2
from the Trouble Display (see “How Do I Access the
Trouble Display?” at the beginning of section 2.3) (see
Zone Display: section 2.3).
2.5.14 Keypad Fault [F OR CE ]
If your keypad is no longer communicating with your alarm
system, the keypad will emit four consecutive beeps at 3second intervals. Press any button on the keypad to
terminate the “beeping” sequence. The [T BL] button will
flash and the [FORCE ] button will illuminate. When
communication has been restored, the keypad will resume
its functions.
12 U ser’s Guide
2.6 PA R T IT ION IN G
Your Spectra system is equipped with a partitioning feature
which can divide your alarm system into two distinct areas
identified as Partition 1 and Partition 2. Partitioning can be
used in installations where shared security systems are
more practical, such as a home office or warehouse
building. When partitioned, each zone, each User Code
and many of your system's features can be assigned to
either Partition 1, Partition 2, or both partitions.
If the system is not partitioned, all zones, User
Codes, and features will be recognized as
belonging to Partition 1.
Spectra LED Keypads 13
3.0 PROGRAMMING ACCESS CODES
Access Codes are personal identification numbers that
allow you to enter certain programming modes, arm or
disarm your system as well as activate or deactivate PGMs
(see section 5.5 on page 29). The Spectra security system
supports the following:
1 System Master Code
2 Master Codes
45 User Access Codes (including 1 Duress code)
For information on how each Access Code can arm or
disarm the system refer to the System Checklist in section
8.0 on page 36.
3.1 SY ST EM M A ST ER COD E (Default: 123456)
The System Master Code can arm or disarm any partition
using any of the methods described in this section and can
create, modify or delete any User Access Code (see
section 3.4 on page 15).
3.2 MA ST ER COD ES
Master Code 1 is permanently assigned to Partition 1 and
can be used to create, modify or delete User Access
Codes (see section 3.4) that are assigned to Partition 1.
Master Code 2 is permanently assigned to Partition 2
(except when partitioning is disabled, Master Code 2 will be
assigned to Partition 1) and can be used to create, modify
14 U ser’s Guide
or delete User Access Codes (see section 3.4) that are
assigned to the same partition.
Master Codes cannot modify or delete User Access
Codes assigned to both partitions. Only the System
Master Code can modify or delete User Access Codes
assigned to both partitions.
3.3 DU RE SS CO DE
If you are forced to arm or disarm your system, entering the
Access Code assigned to User 048 will arm or disarm the
system and immediately transmit a silent alert (Duress
Code) to the Security Company.
The Duress Code feature must be enabled by your
installer.
3.4 PR OG RA M MI NG ACC E SS COD ES
Your system can use either 4- or 6-digit Access Codes (see
page 37), where each digit can be any value from 0 to 9.
Six-digit codes are considered more difficult to “crack” and
therefore, more secure. Avoid programming simple or
obvious access codes, such as your telephone number,
address or codes such as 1234.
Spectra LED Keypads 15
How do I program Access Codes?
1) Press [ENTER]
2) Enter your [MA ST ER CODE ]
[E NTER ] button flashes
3) Enter 3-digit [SECT ION] (see Table 1)
The [N U MBER ] corresponding to the first digit of the existing
code (if programmed) and the [EN TER ] button will illuminate
(see Appendix A)
4) Enter a new 4 or 6-digit [ACCESS C ODE ]
[EN TE R] button flashes. Return to step 3 to enter next code or
press [C LE AR] to exit.
How do I delete Access Codes?
1) Repeat steps 1 to 3 (see above)
2) Press the [F ORC E] button once for each digit in the
Access Code (4 or 6 times) until the keypad emits a
“CONFIR MAT ION BEEP ” then press the [CL EAR] button to
exit.
Table 1: User Code Sections
Section
User Codes
[001]
User Code 001 = Sys tem Master Code
[002]
User Code 002 = M as ter Code 1
[003]
User Code 003 = M as ter Code 2
[004] to [047]
User Code 004 to User Code 047
[048]
User Code 048 or Duress C ode
16 U ser’s Guide
4.0 ARMING & DISARMING
Take full advantage of your Spectra system by familiarizing
yourself with all the arming methods.
If your system is not partitioned (section 2.6), the
system considers everything as belonging to Partition 1
4.1 EX IT D EL A Y
After entering a valid arming sequence, an Exit Delay
Timer will provide you with enough time to exit the
protected area before the system arms. The “R EA DY” Light
will flash during the Exit Delay and the keypad may beep.
During the final 10 seconds, the beeping and the light will
accelerate.
4.2 DISA R M IN G & D EA C T IVA T IN G
AN
AL A R M
To disarm an armed system or an alarm, enter your access
code. An entry point (i.e. front door) will be programmed
with one of two Entry Delay Timers. When an entry point is
opened, your alarm system will not generate an alarm until
this timer elapses or you disarm the system. Any user can
disarm a partition they have been assigned to, except
users assigned with the Arm Only Option . To disarm alarms
generated by a Delayed Fire Zone, please refer to section 6.0.
.
How do I deactivate an alarm?
Enter your [ACC ESS C ODE ].
Spectra LED Keypads 17
How do I disarm the system?
For a Stay or Instant Armed system, go to Step 2.
1) Enter through a designated entry point (i.e. front door).
The keypad will “beep” during the Entry Delay.
2) Enter your [AC CESS
COD E]
After the “ C ONFIRM ATION
BEEP ”, the “AR M”
Light will turn off.
If
you have access to both partitions (see section 2.6):
3) Buttons [1] and [2] will flash. Press the button
corresponding to the desired partition. For both
partitions, press the other button after the
“CONFIR MAT ION BEEP”.
4.3 REGU L A R ARM IN G
This method, commonly used for day-to-day arming, will
arm all the zones in the selected partition.
How do I Regular Arm?
1) Close all zones in the desired partition.
2) Enter your [A CCESS CODE ]
If
you have access to both partitions (see section 2.6):
3) Buttons [1] and [2] will flash. Press the button
corresponding to the desired partition. For both
partitions, press the other button after the
“C ONF IRMATION BEEP ”.
When you have correctly armed the system, the “ARM”
Light corresponding to the armed partition will turn on and
the Exit Delay (see section 4.1) will initiate. Please note
18 U ser’s Guide
that Regular Arming can also be activated using AutoArming (see section 4.9), a Keyswitch (see section 4.8), or
One-Touch Arming (see section 4.7).
4.4 ST A Y A R MI NG
This method allows you to remain in the protected area
while partially arming the system. Stay Zones are zones
that are bypassed when Stay Arming. For example, when
you go to sleep at night, doors and windows can be armed
without arming other zones like motion detectors.
How do I Stay Arm?
1) Close all zones in the desired partition (except Stay
Zones).
2) Press the [STAY ] button
3) Enter your [A CCESS CODE ]
If
you have access to both partitions (see section 2.6):
4) Buttons [1] and [2] will flash. Press the button
corresponding to the desired partition. For both
partitions, press the other button after the
“C ONF IRMATION BEEP ”.
When you correctly Stay Arm the system, the “ARM” Light
corresponding to the armed partition will flash and the Exit
Delay will be initiated (see section 4.1). Stay Arming can
also be activated using Auto-Arming (see section 4.9), a
Keyswitch (see section 4.8) or One-Touch Arming (see
section 4.7).
Spectra LED Keypads 19
4.4.1 Instant Arming
After Stay Arming the system and during its Exit Delay,
press and hold the [STAY ] button for 3 seconds. You should
hear a “CONFIR MAT ION BEEP ”. The system is then Instant
Armed. Therefore, any armed zone that is breached will
immediately generate an alarm.
If you have access to both partitions:
To Instant Arm one partition To Instant Arm both partitions
1) Press the [STAY ] button
1) Press the [STAY ] button
2) Enter your [A CCESS CODE ] 2) Enter your [ACCESS CODE ]
3) Choose a partition
3) Press [1]
4) Press the [CLEAR] button 4) Press [2]
5) Press and hold the [STAY ] 5) Press and hold the [STAY ]
button for 3 seconds
button for 3 seconds
4.5 FOR C E A R MI NG
Force Arming allows you to rapidly arm the system without
waiting for all zones in the system to close. During Force
Arming, a Force Zone is considered “deactivated” until it
closes, then the system will arm that zone. Force Arming is
commonly used when a motion detector is protecting the
area occupied by a keypad. For example, when arming and
the motion detector is a Force Zone, the system will allow
you to arm even if the zone is open.
20 U ser’s Guide
How do I Force Arm?
1) Close zones in the desired partition (except Force Zones).
2) Press the [FORCE ] button
3) Enter your [A CCESS CODE ]
if you have access to both partitions (see section 2.6):
4) Buttons [1] and [2] will flash. Press the button
corresponding to the desired partition. For both partitions,
press the other button after the “C ON FIRMATION B EEP ”.
When you correctly Force Arm the system, the “AR M” Light
corresponding to the armed partition will turn on and the
Exit Delay will initiate (see section 4.1). Force Arming can
also be activated by using One-Touch Force Arming (see
section 4.7.4).
4.6 MA N UA L BYPA SS P R OGR A M MI NG
Manual Bypass Programming allows you to program the
alarm system to ignore (deactivate) specified zones the
next time the system is armed. For example, you may wish
to bypass certain zones when workers are renovating part
of your establishment. Please note that a Fire Zone cannot
be bypassed.
Spectra LED Keypads 21
How do I program bypass entries?
1) Press the [BYP ] button.
2) Enter your [A CCESS CODE ] (see Note1)
3) Illuminate the button(s) corresponding to the zone(s)
you wish to bypass by pressing the corresponding
button. Press the button again to turn it off. Press the
[ FOR C E ] button to eras e all the current zone bypass
entries.
4) Once you have entered the desired bypass entries,
press the [EN TER] button to accept these entries.
5) T HE [B Y P] button w ill turn on when zones are by pass ed.
The nex t time the sys tem is armed, the zones will be
bypass ed.
NOTE1: If you have access to both partitions, buttons
[1] and [2] will flash. Press the button corresponding
to the desired partition. The [BYP] button will flash and
any zones that are already bypassed will illuminate.
4.6.1 Bypass Recall Feature
After disarming the system, the bypass entries are erased.
The Bypass Recall Feature reinstates the previous bypass
entries saved in memory. There is no need to manually
reprogram bypass entries every time you arm the system.
How do I recall bypass entries?
1) Press the [BYP ] button.
2) Enter your [A CCESS CODE ] (see Note1).
3) Press the [BYP ] button.
4) Previously bypassed zones will illuminate.
5) Press the [ENTER] button.
22 U ser’s Guide
4.7 ON E -TOU C H A R MIN G
One-Touch Arming allows you to arm the system without
using an access code.
NOTE2: If both partitions are enabled and you activate
a One-Touch feature, buttons [1] and [2] will flash.
Press the button corresponding to the desired
partition(s).
4.7.1 One-Touch Regular Arming
Press and hold the [ENT ER] button for 3 seconds (see
Note2) to arm all zones in the partition. You can use this
feature to allow specific individuals like service personnel
(i.e. cleaners) to arm without giving them access to any
other alarm system operations. For details on Regular
Arming, refer to section 4.3.
4.7.2 One-Touch Stay Arming
Press and hold the [STAY ] button for 3 seconds (see Note2)
to arm all zones not defined as Stay Zones. For details on
Stay Arming , refer to section 4.4.
4.7.3 Fast Exit
WHEN T HE SYSTEM IS A LREADY ST AY ARMED:
this feature will
allow you to exit already armed premises and keep the
system armed.
Exit and Stay Arm: Press and hold the [STAY ] button for 3
seconds (see Note2) to start the Exit Delay (see section
4.1). When the Exit Delay elapses, the system will return to
Stay Arming .
Spectra LED Keypads 23
Exit and Regular Arm: Press and hold the [ENTER] button
for 3 seconds (see Note2) to start the Exit Delay (see
section 4.1). When the Exit Delay elapses, the system will
switch to Regular Arming (see section 4.3).
Exit and Force Arm: Press and hold the [F OR CE] button
for 3 seconds (see Note2) to start the Exit Delay (see
section 4.1). When the Exit Delay elapses, the system will
switch to Force Arming (see section 4.5).
4.7.4 One-Touch Force Arming
Press and hold the [F OR CE ] button for 3 seconds (see
Note2) to bypass any open Force Zones. For details on
Force Arming, refer to section 4.5.
4.7.5 One-Touch Bypass Programming
Press and hold the [B YP ] button for 3 seconds (see Note2)
to access Bypass Programming Mode (see section 4.6).
4.8 KEY SWI T CH AR M IN G
A keyswitch can be used to arm and disarm the system. A
keyswitch is assigned to and programmed to Stay Arm
(see section 4.4) or Regular Arm (see section 4.3) a
specific partition. A keyswitch can function as a Maintained
or Momentary keyswitch.
To arm the system using a Maintained Keyswitch, set the
keyswitch to the “on” position. To disarm the system set the
keyswitch to the “off” position.
To arm the system using a Momentary Keyswitch, set the
24 U ser’s Guide
keyswitch to the “on” position then turn it back to the “off”
position. Repeating this sequence will disarm the system.
4.9 AU T O -AR M IN G
The Spectra alarm system can be programmed to
automatically arm upon the following two conditions.
4.9.1 Timed Auto Arming
The alarm system can automatically arm itself at a
specified time everyday. As with Regular Arming (see
section 4.3), the system will not arm if a zone is open. If
this occurs, the system will not arm until the next day. Your
installer enables this option, but you can program the time
of day the system will automatically arm.
How do I program the Auto-Arm Timer?
1) Press the [ENTER] button
2) Enter your [MA ST ER CODE ]
[E NTER ] button flashes
3) Enter [101] for Partition 1 or [102] for Partition 2 (see
Appendix A)
4) Enter the desired [T IME ]. Example: 6:15PM = 18:15
A 60-second Exit Delay (see section 4.1) will start
before the system arms. At this point, Auto-Arming can
be cancelled by entering your access code.
4.9.2 “No Movement” Auto Arming
Your panel can be programmed to arm the system and/or
send a report if no zone activity occurs for a preSpectra LED Keypads 25
programmed amount of time. This is a particularly useful
feature when supervising an individual with chronic health
problems or who lives alone.
26 U ser’s Guide
5.0 ADDITIONAL FEATURES
Each keypad must be Chime Programmed and Muted
separately. Keypad Muting must be re-programmed if
your system suffers a total power loss.
When you press and hold a button and the keypad
emits a “CONFIRMATION BEEP”, the chime feature has
been enabled for that zone or Keypad Muting has been
enabled for that keypad. If the keypad emits a
“REJECTION BEEP”, these features have been disabled.
5.1 PR OG RA M MI NG CHI ME ZONE S
This feature allows you to program which zones will be
“Chime Enabled”. A “Chime Enabled” zone will advise you
every time it is opened by causing your keypad to emit a
rapid intermittent beep tone (BEEP -BEEP -BEEP-BEEP ). Press
and hold any button from [1] to [10] for 3 seconds to
activate or deactivate Chiming for zones 1 to 10. For
example, press and hold the [1] button to enable chiming
on zone 1.
5.2 KEY PAD MU T IN G
Press and hold the [C L EA R ] button for 3 seconds to enable
or disable keypad muting. When muted, the keypad will
only emit the “C ONF IRMATION BEEP”, “REJECTION BEEP”, and
beep when a button is pressed.
Spectra LED Keypads 27
5.3 PA N IC A L A RM S
In case of emergency, the Spectra system can provide three
panic alarms that can immediately generate an alarm after
simultaneously pressing and holding two specific buttons for
two seconds. Based on your needs, these panic alarms can
generate audible alarms (sirens or bells) or silent alarms,
both of which can send a message to your Security
Company. The three different panic alarms can
communicate specific messages to your monitoring station.
For instance, pressing [1] & [3] can mean “call the police”
or anything you require.
1) Press & hold buttons [1] and [3] for the police.
2) Press & hold buttons [4] and [6] for a medical alarm.
3) Press & hold buttons [7] and [9] for a fire alarm.
5.4 PR OG RA M TI ME (C LO CK )
How do I program the System Clock?
1) Press the [ENTER] button
2) Enter [MA ST ER C ODE ]
[E NTER ] button flashes
3) Enter [100] (see Appendix A)
4) Enter the desired [ T IM E ].
Example: 6:15PM = 18:15
28 U ser’s Guide
5.5 PGM BU T T ON (P R OGR A MM A BL E OU T PU T S )
Your Spectra system may include one or more
programmable outputs (PGMs). When a specific event or
condition occurs in the system, the PGM can be used to
reset smoke detectors, activate light switches in your home
or office, open/close garage doors and much more. A PGM
can also be programmed to activate whenever the [PG]
button is pressed and held for 3 seconds.
5.6 QU IC K FU NC T IO N KE YS
Upon request of your installer or Security Company you
may have to perform one of the following. Press:
5.6.1 TEST REPOR T
[ EN TE R ] + [ M A STE R
C OD E ]
+ [ M EM ]
If your system is monitored by your Security Company, this
feature will send a test report code to the Security
Company.
5.6.2 C AL L PC
[ EN TE R ] + [ M A STE R
C OD E ]
+ [ B YP ]
Will initiate a call to the Security Company that is using the
upload/download diagnostic software.
5.6.3 Answer PC
[ EN TE R ] + [ M A STE R
C OD E ]
+ [ FOR C E ]
Will force your security system to answer a call made by
your Security Company that is using the upload/download
diagnostic software.
Spectra LED Keypads 29
5.6.4 Cancel Communication
[ EN TE R ] + [ M A STE R
C OD E ]
+ [ S TA Y ]
Cancels all communication with the upload/download
diagnostic software if it has been initiated.
5.7 KEY PAD BA C KL I GH T
The illumination level behind the keys can be modified to
suit the user’s needs. There are four backlight levels. The
[MEM] key is used to set the desired level. Each
consecutive push of the [MEM] key will increase the
backlight level until the maximum level is reached. After
reaching the maximum level, the backlight level will return
to the lowest level and the whole process is repeated. To
change the backlight level:
How do I modify the backlight?
1)
2)
3)
4)
Press and hold the [MEM] key for 3 seconds
The [MEM] key will illuminate
Press the [MEM] key to set the desired backlight level
Press [CL EAR] or [ENTER] to exit
30 U ser’s Guide
6.0 FIRE ALARMS
Upon a fire alarm, the bell/siren will emit three “squawks” at
2 second intervals until silenced or reset by entering a valid
access code. If the zone is a Delayed Fire Zone, there is a
delay before the system contacts the Security Company.
This will prevent unnecessary reporting of false alarms. If
there is no fire condition, contact your Security Company
immediately to avoid an unnecessary response.
What do I do if a Delayed Fire Zone was set off
accidentally?
1) Press the [CL EA R] button within 30 seconds of the
alarm.
2) Try to correct the problem.
3) If the problem persists, the alarm will sound again. Press
[CLEAR] again.
These steps will instruct the system to delay reporting the fire
alarm to the Security Company (see Figure 6-1 for details).
Spectra LED Keypads 31
Figure 6-1: Delayed Fire Zone Flowchart
Minimizing Fire Hazards
The three most common causes of fires:
• Cooking is the leading cause of home fires in the U.S.
It's also the leading cause of fire injuries. Cooking fires
32 U ser’s Guide
often result from unattended cooking and human error,
rather than mechanical failure of stoves or ovens.
• Careless smoking is the leading cause of fire deaths.
Smoke detectors and smolder-resistant bedding and
upholstered furniture are significant fire deterrents.
• Heating is the second leading cause of residential fires.
However, heating fires are a larger problem in single
family homes than in apartments since the heating
systems in single family homes are often not
professionally maintained.
Fire Safety Tips
• In the event of a fire, remember time is the biggest
enemy and every second counts! Escape first, then call
for help. Develop a home fire escape plan and designate
a meeting place outside. Make sure everyone in the
family knows two ways to escape from every room.
Practice feeling your way out with your eyes closed.
Never stand up in a fire, always crawl low under the
smoke and try to keep your mouth covered. Never return
to a burning building for any reason; it may cost you your
life.
• Finally, having at least one working smoke alarm
dramatically increases your chances of surviving a fire.
And remember to practice a home escape plan
frequently with your family.
Providing a Fire Warning System
Household fires are especially dangerous at night. Fires
produce smoke and deadly gases that can overcome
occupants while they sleep. To warn against fire, smoke
Spectra LED Keypads 33
detectors should be installed outside each separate
sleeping area in the immediate vicinity of the bedrooms
and on each additional story of the family living unit,
including basements.
34 U ser’s Guide
7.0 TESTING & MAINTENANCE
With the system disarmed and the “R EA DY ” Light on,
activate motion detectors by walking in the protected area.
Open and close protected doors and verify that the
corresponding button illuminates. Your installer can advise
you of the best way to test your particular system.
Do not use open flame or burning materials to test your fire
detection devices. Contact your installer for safe methods
of testing your system.
Under normal use, your system requires virtually no
maintenance other than regular testing. It is recommended
that the standby battery be changed every three years.
Speak to your installer about the necessary tests and at
what frequency they should be performed.
Spectra LED Keypads 35
8.0 SYSTEM CHECKLIST
Zone Description
Is this system partitioned?
Yes N
No N
Partition 1 = ____________________________________
Partition 2 = ____________________________________
Zone # and
Description
Partition
Entry
Byp Stay F orce 24Hr
1 or 2
Delay
01:______________
____
N
N
N
N
____
N
N
02:_____________
Keys witch? Y N N N
Ty pe:____________
03:______________
Fire Zone? Y N N N
Delayed? Y N N N
____
N
N
N
N
N
04:______________
____
N
N
N
N
N
05:______________
____
06:______________
____
N
N
N
N
N
07:______________
____
08:______________
____
09:______________
____
10:______________
____
11:______________
____
12:______________
____
13:______________
____
36 U ser’s Guide
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
Zone # and
Description
Partition
Entry
Byp Stay F orce 24Hr
1 or 2
Delay
14:______________
____
15:______________
____
16:______________
____
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
Access Codes
For security reasons, write only the user’s name and not his or
her access code. 4-Digit Codes N
6-Digit Codes N
User # and N am e
Partition
Arm
Byp Stay Force
1 or 2
Only
PGM
Only
1 &2
> > >
N
____
N
N
N
N
N
____
N
N
N
N
N
004:___________
____
N
N
N
N
N
005:___________
____
006:___________
____
N
N
N
N
N
007:___________
____
008:___________
____
009:___________
____
010:___________
____
011:___________
____
001:___________
System Master Code
Default: 123456
002:___________
Master Code 1
003:___________
Master Code 2
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
Spectra LED Keypads 37
User # and N am e
Partition
Arm
Byp Stay Force
1 or 2
Only
012:___________
____
013:___________
____
014:___________
____
015:___________
____
016:___________
____
017:___________
____
018:___________
____
019:___________
____
020:___________
____
021:___________
____
022:___________
____
023:___________
____
024:___________
____
025:___________
____
026:___________
____
027:___________
____
028:___________
____
029:___________
____
030:___________
____
031:___________
____
032:___________
____
38 U ser’s Guide
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
PGM
Only
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
User # and N am e
Partition
Arm
Byp Stay Force
1 or 2
Only
033:___________
____
034:___________
____
035:___________
____
036:___________
____
037:___________
____
038:___________
____
039:___________
____
040:___________
____
041:___________
____
042:___________
____
043:___________
____
044:___________
____
045:___________
____
046:___________
____
047:___________
____
048:___________
Duress: Y N N N
____
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
PGM
Only
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
Special Buttons and Features
N [ENTER] One-touch Regular Arming is activated
N [STAY ] One-touch Stay Arming is activated
N [FORCE ] One-touch Force Arming is activated
N [BYP] One-touch Manual Bypass Programming is activated
Spectra LED Keypads 39
Panic Alarms:
[1] & [3] Police or __________ N Silent N Audible NOff
[4] & [6] Aux. or ___________ N Silent N Audible NOff
[7] & [9] Fire or ___________ N Silent N Audible NOff
PGMs:
PGM 1: ________________________________________
PGM 2: ________________________________________
PGM 3: ________________________________________
System Timers
Enter and exit your premises through the designated
doors.
Exit Delay 1 (Partition 1): _______sec. = time to exit site
Exit Delay 2 (Partition 2): _______sec. = time to exit site
Entry Delay 1 = _______sec. = time to disarm before
alarm; enter through zone #___________
Entry Delay 2 = _______sec. = time to disarm before
alarm; enter through zone #___________
Alarm will activate siren or bell for ______ min.
Other Information
Installed by:__________________ Date: ____________
Serviced by:__________________ Tel: ______________
Monitored by:_________________ Tel: _______________
Your account number: ____________________________
Alarm transformer location:________________________
on circuit #:____________
Location of Telephone Connections:
______________________________________________
40 U ser’s Guide
9.0 APPENDIX A
Your Spectra keypad can display data one of two ways
when you to program the following parameters :
• User Access Codes (see section 3.4)
• System’s Clock (see section 2.5.8 & section 5.4)
• Auto-Arm Time (see section 4.9)
Do not read the following if you have not read the
above mentioned sections.
After entering the 3-digit section you wish to program, the
[ENTER] button will flash. If a value is programmed, the
number corresponding to the first digit of the programmed
value will also illuminate. At this point, you can begin
entering the required data. After entering a digit, the
number corresponding to the following programmed digit
will illuminate and so forth. For example, if you wish to
change User Code 004 from 123456 to 454545, after
entering section [004], button [1] will turn on. Press the [4]
button and button [2] will turn on, then press the [5] button
and button [3] will turn on...
OR
After entering the desired 3-digit section and before
entering any data, press the [ENTER] button to access the
Data Display Mode. The [ARM1], [ARM2] and “READY ” Lights
will flash. Once in the Data Display Mode, pressing the
[ENTER] button will scroll through the digits of the current
section. When viewing the last digit in the section, pressing
the [ENTER] button will automatically exit the section.
Warranty
Spectra LED Keypads 41
The Seller warrants its products to be free from defects in
materials and workmanship under normal use for a period
of one year. Except as specifically stated herein, all
express or implied warranties whatsoever, statutory or
otherwise, including without limitation, any implied warranty
of merchantability and fitness for a particular purpose, are
expressly excluded. Because Seller does not install or
connect the products and because the products may be
used in conjunction with products not manufactured by
Seller, Seller cannot guarantee the performance of the
security system. Seller obligation and liability under this
warranty is expressly limited to repairing or replacing, at
Seller's option, any product not meeting the specifications.
In no event shall the Seller be liable to the buyer or any
other person for any loss or damages whether direct or
indirect or consequential or incidental, including without
limitation, any damages for lost profits, stolen goods, or
claims by any other party caused by defective goods or
otherwise arising from the improper, incorrect or otherwise
faulty installation or use of the merchandise sold.
780 boul. Industriel, St. Eustache, Montréal, Québec J7R 5V3
F ax: (450) 491-2313
ww w.paradox.ca
P RIN TE D IN CA NA DA 11/2002
1686EU-05

advertisement

Was this manual useful for you? Yes No
Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project

Related manuals

Frequently Answers and Questions

What does the illuminated [1] button indicate?
The backup battery is disconnected or the battery voltage is getting low.
What does the illuminated [2] button indicate?
The battery voltage in one or more Wireless Transmitters is getting low.
What does the illuminated [3] button indicate?
The system has detected a loss of AC power, usually during a power failure.
What does the illuminated [4] button indicate?
The bell, siren, or any device connected to the PGM2 is no longer connected to the alarm system.
What does the illuminated [5] button indicate?
During an alarm, the bell output has automatically shut down due to excessive current.