K10V/H - User`s Quick Reference Guide KEYPAD

K10V/H - User’s Quick Reference Guide
KEYPAD OVERVIEW
Partition 1 Status Partition 2 Status
On = StayD
Mode Enabled
Arm (red), Sleep (yel), Stay (grn):
On
= Partition armed
Off
= Partition disarmed
Flash
= Exit Delay
Fast Flash* = Exit Delay (final 10
sec.)
Fast Flash* = Partition in alarm
Off Light (red):
On
= Disarmed
Off
= System armed
AC Light
On = Power on
Off = Power off
* Audible Indicators:
Continuous beep = Alarm
Variable beep = Fire alarm
Intermittent beep = Beginning of
exit delay
Fast beep = Final 10 sec. of exit
delay
Zone Display:
Keys [1] to [0(10)] correspond
to zones 1 to 10 respectively.
Key Lit: Open or entry delay
Key Flash: In alarm
[TBL] Trouble display
On = Trouble(s) occurring
[MEM] Alarm memory display
On = Alarm(s) occurred
[BYP] Bypass programming
On = Zone(s) bypassed
= Press once + [MASTER
CODE] for Quick Menu
Programming
ARMING AND DISARMING
TO ARM
WHEN STAYING...
TO ARM
WHEN LEAVING...
To Regular Arm:
1. Close all zones in the desired
partition.
2. Press [ARM].
3. Enter your [ACCESS CODE]*.
To Stay Arm:
1. Press the [STAY] key.
2. Enter your [ACCESS CODE]*.
To Sleep Arm:
1. Press the [SLEEP] key.
2. Enter your [ACCESS CODE]*.
To Disarm:
[OFF] + [ACCESS CODE]*
* If needed, press button(s) corresponding to desired partition(s). For two partitions, press the other key after
the confirmation beep.
PANIC ALARMS
ALARM MEMORY DISPLAY
To send a silent or audible alarm to
your Security Company, press and hold
one of the button combinations listed
for 3 seconds.
To view the alarms that occurred during
the last armed period:
1. Disarm the system.
2. Press the [MEM] key.
3. The corresponding zone
numbers that were in alarm the
last time the system was armed
will illuminate.
4. Press the [CLEAR] key to exit.
Panic Alarm Type
Button
Combinations
Police
Medical
Fire
Press [1] & [3]
Press [4] & [6]
Press [7] & [9]
TROUBLE DISPLAY
When a trouble condition occurs, the
[TBL] key will illuminate.
1. Press the [TBL] key. The key will
flash and number(s) corresponding to the trouble(s) will illuminate.
2. Read the corresponding
explanation from the trouble list
in the MG5000 User Guide.
3. Press the [CLEAR] key to exit.
KEYPAD SETTINGS
To mute the keypad:
Press and hold the [CLEAR] key
for 6 seconds to enable or
disable Keypad Muting.
To modify the backlight:
1. Press and hold the [MEM] key for
3 seconds.
2. The [MEM] key will illuminate.
3. Press the [MEM] key to set the
desired backlight level.
4. Press [CLEAR] or [ENTER] to exit.
CHIME PROGRAMMING
BYPASS PROGRAMMING
Bypassed zones remained unarmed
when the partition is armed.
1. Press the [BYP] key.
2. Enter your [ACCESS CODE]*.
3. The corresponding key of all
open zones will illuminate. Select
the zone(s) you want to bypass
by entering the one-digit zone
number. The zone key will flash.
4. Press the [ENTER] key to save
and exit.
A Chime Enabled zone will advise you
every time it is opened by causing your
keypad to beep.
1. Press & hold the corresponding
zone key for 3 seconds (Accept
beep = Chime enabled, Fail beep
= Chime disabled).
© Paradox Security Systems Ltd., 2005-2015.
Magellan is a trademark or registered trademark
of Paradox Security Systems (Bahamas) Ltd.
and its affiliates in Canada, the United States
and/or other countries. All rights reserved.
PARADOX.COM
Printed in Canada 11/2015