iWAVE Wireless PIR-PET Detector Installation Instructions

6
2.2m-2.5m
(7'-8')
T
EN Registering the Detector into the system
1
2
3
The iWAVE must identify itself to the system receiver. This can be done by typing
the 11 digit serial number of the detector into the system or using RF mode. To
register the detector using the serial number refer to the Agility installation manual.
Enrolling using RF communication
1.Set the receiver to Learn mode.
2.Insert the batteries and press the tamper switch for at least 3 seconds. The
iWAVE will send a WRITE message. A successful learning will be indicated by a
confirmation message that indicates the detector allocation in the system.
IT Registrare il rilevatore nel sistema
iWAVE deve essere identificato dal ricevitore del sistema. Inserire pertanto il
numero di serie a 11 cifre del rilevatore nel sistema o utilizzare la modalità RF. Per
registrare il rilevatore utilizzando il numero di serie, fare riferimento al manuale di
installazione Agility.
Acquisizione tramite comunicazione RF
1.Impostare il ricevitore in modalità di apprendimento.
2.Inserire le batterie e premere l’interruttore tamper per almeno 3 secondi. iWAVE
invierà un messaggio WRITE. Il corretto apprendimento viene confermato da un
messaggio indicante l’allocazione del rilevatore nel sistema.
SP Registro del detector en el sistema
PIR & PIR Pet Detectors
El iWAVE debe identificarse en el receptor del sistema. Esto puede hacerse
escribiendo en el sistema el número de serie de 11 dígitos del detector, o bien
usando el modo RF (Radio Frecuencia). Para registrar el detector usando el número
de serie, consulte el manual de instalación de Agility.
Alta del detector usando la comunicación RF
1. Ponga el receptor en modo Aprendizaje.
2. Inserte las pilas y pulse el interruptor del tamper durante al menos 3 segundos. El
iWAVE enviará un mensaje de Escritura. Si se ha dado de alta correctamente, se
oirá un mensaje de confirmación indicando la asignación del detector en el sistema.
FR Enregistrement du détecteur dans le système
www.riscogroup.com
www.riscogroup.co.uk
www.riscogroup.fr
www.riscogroup.it
www.riscogroup.com/dutch
www.riscogroup.es
www.riscogroup.com/por
www.riscogroup.com/cn
Le modèle iWAVE doit être identifié par le système récepteur. Ceci peut être fait en
entrant les 11 chiffres du numéro de série du détecteur dans le système ou en
employant le mode RF. Pour enregistrer le détecteur en utilisant le numéro de
série, consultez le manuel d'installation de l'Agility.
3A
5
4
-10°C > 40°C
(14°F > 104°F)
Utilisation de la communication RF pour l'inscription
1.Réglez le récepteur en mode d’apprentissage
2.Insérez les batteries et appuyez sur le commutateur du dispositif anti-sabotage
durant au moins 3 secondes. Le iWAVE enverra un message ECRIT. Un message
de confirmation indiquant que l’inscription du détecteur dans le système a réussi
apparaîtra.
PR Registrando o detector no sistema
O iWAVE deve identificar-se ao receptor do sistema. Isto pode ser executado ao
digitar o número de série de 11 dígitos do detector no sistema ou utilizando o modo
de rádio freqüência. Para registrar o detector utilizando o número de série, consulte
o manual de instalação da Agility
Inscrição através de comunicação de rádio freqüência
1.Configure o receptor para o modo "Learn".
2.Introduza as pilhas e pressione o interruptor do tamper por pelo menos 3
segundos. O iWAVE enviará uma mensagem WRITE. Um aprendizado bem
sucedido será indicado por uma mensagem de confirmação que indica a atribuição
do detector no sistema.
PIR 868/433MHz
Model: iWAVE T95
NL De detector in het systeem registreren
EN Caution: Risk of explosion if battery is replaced by an incorrect type. Dispose of used batteries according
PIR Pet 868/433MHz
Model: iWAVE T95P
to local regulations.
IT Attenzione: Pericolo di esplosione in caso di utilizzo di un tipo di batterie non adeguato. Smaltire le
batterie secondo la normativa vigente.
SP Advertencia: Si la batería se sustituye por un tipo incorrecto, hay riesgo de explosión. Deshágase de las
baterías usadas según las regulaciones locales
FR
x1
x3
x2
< 36kg (80lb)
Mise en garde : risque d'explosion si la pile est remplacée par un type incorrect.
Débarrassez-vous des batteries usagées en accord avec les règlementations locales.
PR Cuidado: Pode ocorrer o risco de explosão caso substituir as pilhas por outras de tipo indevido. É
necessário desfazer-se das pilhas usadas de acordo com os regulamentos locais.
NL Let op: Als de accu met een verkeerd type wordt vervangen, onstaat de kans op explosie. Gebruikte
accu's moeten volgens de lokale reguleringen worden
De iWAVE moet zichzelf bij de systeemontvanger identificeren. Dit kan
worden gedaan door het digitale serienummer 11 van de detector in het
systeem of met RF-modus te typen. Om de detectors met het
serienummer te registreren, moet u de installatiehandleiding van het
systeem raadplegen.
Met RF-communicatie registreren:
1.Stel de ontvanger in op de modus Leren
2.Plaats de accu’s en druk op gedurende minstens 3 seconden op de
sabotageschakelaar. De iWAVE verzendt een bericht SCHRIJVEN. Een
succesvol leren wordt door een bevestigingsbericht aangegeven, welke de
toewijzing van de detector in het systeem aangeeft.
7
8
A
B
9
C
NO
O
ON
2
1
3
4
(Default)
IT
Mode
OFF
Sensitivity
Low
High
2
Operation
Normal
2.5min
Walk
Test
4
Sensibilita’
OFF
ON
Bassa
Alta
OFF
ON
Sensibilidad
Modo
Normale Prova
operativo 2.5min Movimento
Supervision 15 min. 65 min. Supervisione 15 min.
LED
FR
Modo
Función
ON
1
3
SP
Modo
Funzione
Function
LED
OFF
65 min.
ON
O
Funcionamiento
OFF
ON
Baja
Alta
Sensibilité
OFF
65 min.
Operation
Faible
Elevé Sensibilidade
Normal Test de
2.5min passage
ON
LED
OFF
Operação
OFF
ON
Baixa
Alta
Normal Teste de
2.5min Caminhada
ON
LED
OFF
65 min.
ON
3
m
30 9
PIR - TOP VIEW
11
15
20
7
15
5
10
4
10 3
4
5
ON
1
5
2
3
0
4
5
5
2
1
0
0
5
1
10
2
10 3
Normal
2.5 min.
15
15
4
20
5
20 6
25
ft
25
8
20 6
0-20Min
2
12A
12
ft
25
O
1
ON
Surveillance 15 min. 65 min. Monitoração 15 min.
10
ON
Modalidade
Função
OFF
Normal Prueba de
2,5min. Detección
Supervisión 15 min.
LED
PR
Mode
Fonction
25
7
8
30
30 9
0
1
0
2
5
ft. m
10 3
5
3
10
4
15
5
6
20
7
25
8
9 10 11 12 13 14 15 m
35 40 45
50 ft
30
PIR - SIDE VIEW
0
1
0
0
0
1
2
5
3 4 5 6 7 8 9 10 11 12 13 14 15 m
10 15
20
25
30 35 40 45
50 ft
7
CR 123, 3V Lithium
6
5
3 4
4
2
1
3
2
B
C
IT
SP
RISCO Group Limited Warranty
RISCO Group and its subsidiaries and affiliates ("Seller") warrants its products to be free from defects in materials and workmanship under normal use for 24 months from the date of
production. Because Seller does not install or connect the product and because the product may be used in conjunction with products not manufactured by the Seller, Seller cannot
guarantee the performance of the security system which uses this product. Seller's obligation and liability under this warranty is expressly limited to repairing and replacing, at Seller's
option, within a reasonable time after the date of delivery, any product not meeting the specifications. Seller makes no other warranty, expressed or implied, and makes no warranty
of merchantability or of fitness for any particular purpose. In no case shall seller be liable for any consequential or incidental damages for breach of this or any other warranty,
expressed or implied, or upon any other basis of liability whatsoever. Seller's obligation under this warranty shall not include any transportation charges or costs of installation or any
liability for direct, indirect, or consequential damages or delay. Seller does not represent that its product may not be compromised or circumvented; that the product will prevent any
personal injury or property loss by burglary, robbery, fire or otherwise; or that the product will in all cases provide adequate warning or protection. Buyer understands that a properly
installed and maintained alarm may only reduce the risk of burglary, robbery or fire without warning, but is not insurance or a guaranty that such event will not occur or that there will
be no personal injury or property loss as a result thereof. Consequently seller shall have no liability for any personal injury, property damage or loss based on a claim that the product
fails to give warning. However, if seller is held liable, whether directly or indirectly, for any loss or damage arising under this limited warranty or otherwise, regardless of cause or
origin, seller's maximum liability shall not exceed the purchase price of the product, which shall be complete and exclusive remedy against seller. No employee or representative of
Seller is authorized to change this warranty in any way or grant any other warranty. WARNING: This product should be tested at least once a week.
FR
PR
NL
United Kingdom
Tel: +44-161-655-5500
technical@riscogroup.co.uk
Spain
Tel: +34-91-490-2133
support-es@riscogroup.com
Belgium
Tel: +32-2522 7622
support-be@riscogroup.com
Brazil
Tel: +1-866-969-5111
support-br@riscogroup.com
Poland
Tel: +48-22-500-28-40
support-pl@riscogroup.com
Italy
Tel: +39-02-66590054
support@riscogroup.it
France
Tel: +33-164-73-28-50
support-fr@riscogroup.com
USA
Tel: +1-631-719-4400
support-usa@riscogroup.com
China
Tel: +86-21-52-39-0066
support-cn@riscogroup.com
Israel
Tel: +972-3963-7777
support@riscogroup.com
6
7
PIR: 9 A standby
Pet: 13 A standby
1
2
T
3
15 min.
65 min.
4
5
6
= 5 Y Typical
= 3 Y Typical
7
8
90
0
1
2
5
3
10
4
15
5
6
20
7
25
8
9 10 11 12
30
35
40
SIDE VIEW
2
67.5mm
(2.6")
56mm
(2.2")
1
0
0
1
2
5
3 4 5
10
15
6 7 8
20 25
9 10 11 12 m
30
35 40 ft
sensitivity settings. For low sensitivity setting, the actual detection pattern must be assured
during the installation
Questo metodo di rilevazione è assicurato e approvato in accordo con la norma EN50131
solo quando il rilevatore è in ALTA SENSIBILITA’. Per il settaggio in bassa sensibilità, questo
metodo di rilevazione è assicurato solamente durante l’installazione.
Estos patrones de detección sólo están garantizados y aprobados conforme a EN50131 en la
configuración de Alta sensibilidad. Para la configuración de Baja sensibilidad, el patrón exacto
de detección debe asegurarse durante la instalación.
Cette couverture de détection n’est assurée et approuvée selon la norme EN50131 qu’avec
un réglage en Haute Sensibilité. Pour un réglage avec une Faible Sensibilité, la couverture de
détection devra être vérifiée au cours de l’installation.
Este padrão de detecção só é garantido e aprovado de acordo com a EN50131 com o
ajuste para alta sensibilidade. Para ajuste de baixa sensibilidade, o padrão real de
detecção deve ser certificado durante a instalação.
Deze detectie patroon, in lijn met de EN 50131 norm, zijn alleen geldig als de parameters op
het maximum gevoeligheid niveau afgesteld zijn. Voor een lager detectie niveau, de detectie
patroon zou op het moment van de installatie moeten afgesteld worden.
Contacting RISCO Group
RISCO Group is committed to customer service and product support. You can contact us through our website www.riscogroup.com or as follows:
5
0
EN These detection pattern is only assured and approved according to EN50131 in High
A
A
868.65MHz / 433.92MHz
1
ft m
10 3
5
2
PIR Pet - TOP VIEW
m
8
132mm
(5.1")
EN
SW1
APPROVALS
(Models: iWAVE T95 and iWAVE T95P)
EN50131-1, EN50131-2-2 Grade 2 ,EN50130-5 Environmental Class II,
EN50131-6: Type C EN50131–5-3 Grade 2
-10°C > 40°C
(14°F > 104°F)
FCC part 15 statement and warnings
(Models: iWAVE T95 and iWAVE T95P)
NOTE: This equipment has been tested and found to
comply with the limits for a Class B digital device, pursuant
to Part 15 of the FCC Rules. These limits are designed to
provide reasonable protection against harmful interference
in a residential installation. This equipment generates, uses
and can radiate radio frequency energy and, if not installed
and used in accordance with the instructions, may cause
harmful interference to radio communications. However,
there is no guarantee that interference will not occur in a
particular installation. If this equipment does cause harmful
interference to radio or television reception, which can be
determined by turning the equipment off and on, the user is
encouraged to try to correct the interference by one or
more of the following measures:
-- Reorient or relocate the receiving antenna.
-- Increase the separation between the equipment and
receiver.
-- Connect the equipment into an outlet on a circuit different
from that to which the receiver is connected.
-- Consult the dealer or an experienced radio/TV technician
for help.
FCC ID: JE4RWT90X433
© RISCO Group 12/2009
5IN1088 C
Download PDF