1. Introductions
3. Terminal Description
5. Mounting
This manual is just a guide for quick installation. For more detail instructions,
please refer to DT system technical guide.
CTR
GND
GND
VIO
POW
C1
SET
L2
298.5 mm
CN-LK
L1
CN/WGN
+12V: 12VDC power output.
LK-: power ground.
LK+: common contact of the relay.
NO.: normally open contact of the relay
45
EB+: exit button positive connection port.
EB-: exit button negative connection port.
JP-LK: for electronic lock safety type setting(refer to door lock connections).
SET : DIP switches for system configurations.
CN/KMB: call button module connection port.
CN/T-COIL: reserved.
CN/FUN:
port.
touch sensor keypad module or TFT display module connection
• CN/WGN: card reader module connection port.
• Bus(L1,L2): non-polarity bus line,connect to PC6(power comb unit).
Surface mounted
LED Indicator
Nameplate
Call button
4. Place Name Label
123 mm
Press down and move right/left to open the transparent nameplate cover. Then insert the name paper and put the cover back. Note that the double row button panel
can be opened in both direction, single row button can only be opened at right
side.
Da
Mounting box for
flush mounted
vid
Calo
name paper
Rainy cover for
surface mounted
Note:Key A and key B will not be seen on the panel,they are cryptic.About
activating key A and key B, please refer to Part 7.
-1-
mm
WG0
CN/FUN
12V
TX1
RX1
TX3
RX3
GND
5CL
308 mm
114.5
WG1
GND
12V
CN/T-COIL
GND
Connection
port
GND
L1 L2
INT
RF CARD
DIP
1 2 3 4 5 6
5DA
B
CN/KMB
RST
ID Card Window
ON
A
JP-LK
+12V
Microphone
Status Indicator
LK-
Night View LED
LK+
Speaker
Camera Lens
NO
2. Parts and Functions
•
•
•
•
•
•
•
•
•
•
•
EB-
The keypad module can be assembled with call buttons outdoor station, and
users can open the door with password,about the keypad configurations,
please refer to DT system technical guide.
1 2 3 4 5 6
EB+
The DMR11S with the modular design has a high flexibility,for example,video
entry module and card reader module can be assembled with call buttons
outdoor station, the users can swipe cards to open the door. About the card
configurations, please refer to DT system technical guide.
DIP
STR
C2
ON
The door stations are used as speaking and operating units for the door communication system at the front door.Via the door station,a call is connected to
the desired home station after a call button is pressed.
GND
12V
CLK
DAT
Half flush mounted
-2-
-3-
mm
8. Electric Lock Connection
6. System Connection
To next
DBC4A
Code=2
A B C D
Impedance
switch
Code=1
OFF ON
DBC4A
Code=3
Code=0
AC~
100~240VAC
PC6
ID Code=0
1. The door lock is limited to 12Vdc, and holding current must be less than
250mA when using internal power supply mode.
2. The Unlock Mode Parameter must be set to 0 (by default).
3. Jumper set to 1-2 position for power-off-to-unlock safety type(Normally
closed mode); set to 2-3 position for power-on-to -unlock type(Normally
open mode ).
4. If different unlocking time is needed,change the unlock time on door
station,detail information refer to DT system technical guide .
Power-on-to-Unlock type:
BUS(IM) BUS(DS)
BUS(IM)
1) Door Lock Controlled with Internal Power
BUS(DS)
12V 300mA
• Note: the sketch map is taken DT47M monitor for example.
7. DIP Switches Settings
ON(1)
ON
1
2
3
4
5
Jumper position in 2-3
+12V
LK LK+
N.O.
EBEB+
+
Exit button
1 2 3
Jumper position in 1-2
JP_LK
1 2 3
RF CARD
JP_LK
2) Door Lock Controlled with External Power
Totally 6 bits can be configured by dip-switch. All switches can be modified
either before or after installation, please restarting the power whenever the
switches have been modified.
ON
Exit button
6
=
OFF(0)
ON
=
• Bit-1 and Bit 2 are used for door station ID settings. When
1. The external power supply must be used according to the lock.
2. The jumper must be taken off before connecting.
3. Setup the Unlock Mode Parameter for different lock types
• Power-on-to-unlock type:Unlock Mode=0(by default)
• Power-off-to-unlock type:Unlock Mode=1
4. If different unlocking time is needed, change the unlock time on door
station,detail information refer to DT system technical guide .
Power-on-to-Unlock type:
multi door stations are installed in the system, these two bits must be set
correctly, the first door station set to 00, the second one set to 01, the
third one set to 10, the fourth one set to 11. If only one door station is
installed, set to 00.
• Bit-3 is used for single or double row button door station
selection. If the door station is a double row button, such as DMR11S-
D8, set this bit to 0. For single row button door station,set to 1.
• Bit-4 is used for button code selection. If use the default codes
for each button of the door station, set to 0. If use the programmed codes,
set to 1.(the code for each button can be programmed by software, detail
information refer to DT system technical guide)
• Bit-5 is used for unlocking time setting. 0 is the default
setting,and the default time is 1 second. If set to 1,the unlock time is 5
seconds(the unlock time can be modified by door station or software)
• Bit-6 is used for activating the key A and key B. Normally
key A and key B are not activated(about the functions of key A and key
B,please refer to DT system technical guide ),Just when it set to 1,key A
and key B are activated.
-4-
+
-
Exit button
DMR11S/S8
DMR11S/D16
DMR11S/ID/S4
RF CARD
DMR11S/ID/D8
DMR11S/S4/F1
DMR11S/D8/F1
EP11S/S12
EP11S/D24
R21/LB
R21/ID
R21/S4
R21/D8
Power-off-to-Unlock type:
Cut off the line
+
Take off the Jumper
Quick Installation Guide
12V 300mA
+12V
LK LK+
N.O.
EBEB+
+
2-wire Color ARS Camera
Modularity Outdoor Station
Power-off-to-Unlock type:
RF CARD
-
DMR11S Door Station
+
+12V
LK - (GND)
LK+(COM)
N.O.
EBEB+
-
+
-
1 2 3
Exit button
JP_LK
Take off the Jumper
Cut off the line
+12V
LK - (GND)
LK+(COM)
N.O.
EBEB+
1 2 3
DMR11S/F2
JP_LK
Modules
9. Specification

•
•
•
•
•
•
Power supply: Power Consumption: Unlock Power output: Unlock timing: Working temperature: Dimension:
26Vdc(supplied by PC6)
1W in standby, 5W in working
12Vdc,250mA
1~99s
- 20ºC ~ +55ºC
313(H)×128(W)×63(D)mm(flush)
313(H)×128(W)×70(D)mm(surface)
-5-
R21/TFT
1
2
4
5
7
8
3
*
6
0
9
#

R21/TK
Please read this manual carefully before using the product you purchase, and keep it
well for future use.We reserve the right to modify the specification in this manual at any
time without notice.