HMR3.1/A Magnetic card reader

6
334
HOTEL SOLUTION™
Magnetic card reader
HMR3.1/A
Magnetic card reader for hotel room access control
•
•
•
•
•
Reads access code from Track 2 of the card's magnetic strip
Transfers access code to HRC3.. room controller
Built-in illuminated display of messages from hotel room
Messages indicated by LEDs behind imprinted symbols
Membrane switch for doorbell feature
Application
The HMR3.1/A magnetic card reader is used in conjunction with the HRC3.. room
controller. The magnetic card access code is on Track 2 of the magnetic strip. Guest
and hotel-staff access codes are read by the HMR3.1/A magnetic card reader and
transmitted to the HRC3.. room controller for access control.
CM2N6334en
31.07.2008
Building Technologies
Functions
The HMR3.1/A magnetic card reader communicates with the HRC3.. room controller
via a serial port, performing the following functions:
• Reads access code from Track 2 of the card's magnetic strip
• Transfers the access code, after reading, to the HRC3.. room controller
• Activates the functions programmed in the HRC3.. room controller based on the
access code concerned (guest code, hotel staff code, invalid code).
• Transfers the membrane switch signal for the optional doorbell feature
• Displays signals from the HRC3.. room controller with illuminated LEDs behind
imprinted symbols
Types
HMR3.1/A
Magnetic card reader
Ordering
When ordering, please specify the quantity, product name and type code:
Example
30
Magnetic card readers
HMR3.1/A
Compatibility
Please refer to the assortment overview, N6301.
Mechanical design
Basic design
The HMR3.1/A magnetic card reader comprises the following:
• Component assembly (carrier, printed circuit board, four LEDs, membrane switch,
magnetic card reader-unit and terminal block)
• Front-plate unit
• Operator panel
The components are snap-mounted in the front-plate unit. The operator panel label has
an adhesive strip on the back. After removal of the protective backing, this label can be
affixed to the front plate.
Display
Depending on the standard application configured in the HRC3.. room controller, the
following room states can be displayed:
•
•
•
•
•
•
•
Do not disturb
"Make up room" or "Room service" call
"SOS" call
"Guest present" indicator (for hotel staff only)
Door open
Door closed
Access denied
2/6
Siemens
Building Technologies
HMR3.1/A – Magnetic card reader
CM2N6334en
31.07.2008
Key to symbols
The symbols are shown in white on the black background of the front plate.
T1
V3
V5
V2
V6
Membrane switch for doorbell feature
Yellow LED (room service)
Yellow LED (do not disturb)
Red LED (door closed)
Green LED (door open)
Engineering notes
The magnetic card reader is designed for flush wall mounting in conjunction with baseframes and cover-frames from various manufacturers:
−
−
−
−
−
SIEMENS-DELTA futura
VIMAR idea
Bticino Classic
GEWISS Playbus
AVE Systema 45
Up to four card readers can be connected to the same room bus.
The address is set with 2 DIL switches on the back of the unit (see below).
STOP
Caution
The maximum permitted current associated with the supply voltage from the HRC3.. room
controller must not be exceeded (for further information, see data sheets N6313, N6314.)
Mounting
• The HMR3.1/A magnetic card reader must be mounted outside the hotel room at the
same height as the light switch.
• First press the card holder into the base-frame and then attach the adhesive label to
•
•
•
•
•
•
•
•
the front plate. If the front-plate label is fitted first, it is then difficult to press the card
holder into the base-frame. To remove the unit, it must be unscrewed from the wall
together with the base frame.
Ensure that there is enough spare cable in the mounting box to allow operation of
the DIL switches on the PCB (for addressing).
The device is designed for fixed installation in a dry, enclosed space.
For installation in a 4-module mounting box, depth 70 mm
Mount horizontally only, with the front plate vertical
Do not install AC 230 V devices in the same mounting box
Commissioning must be carried out by trained personnel only
Do not open the unit
Local safety and installation regulations must be observed
3/6
Siemens
Building Technologies
HMR3.1/A – Magnetic card reader
CM2N6334en
31.07.2008
Commissioning
If several devices are operated by the same room controller, an address must be set for
each one.
Only one device will operate with the factory-set default.
Bus address
0x38
0x39
0x3A
0x3B
Note
Switch 1
off
off
on
on
Switch 2
off
on
off
on
In the standard application with only one reader, the HMR3.1/A magnetic card reader
should be programmed with Address 0x3B. Address 0x3B (both DIL switches ON) is
the factory setting for the HMR3.1/A magnetic card reader.
Technical data
Power supply (from HRC3..) Working voltage (SELV)
Current
Magnetic card reader
Reading speed
Service life
Track
Magnetic cards
Format
Membrane switches
Bus interface
Display
Reflective sensor
Environmental conditions
Standards
Electromagnetic
compatibility
Housing protection
Protection class
conformity
UL/CUL approval
Dimensions
Color
Weight
Service life
Type
Transmission speed
Bus voltage
Luminous intensity of LEDs:
Range
Wavelength of light beam:
Operating temperature:
Transport temperature:
Humidity:
Air pressure during operation:
Air pressure during transportation:
Safety of IT equipment
Emitted interference in residential areas
Interference immunity in industrial areas
to EN 60529
to EN 61 140
Meets the requirements of EMC Directive
See also dimension diagrams
Suitable for flush mounting in 4-module
rectangular flush-mounting box or cavitywall box
Plastic components
Front-plate label
Excluding packaging
With packaging
DC 9..15 V
25 mA max.
10 ... 150cm/s
500,000 read cycles
Track 2, ISO 7810
86 x 54 x 0.76 mm
LoCo magnetic strip
100,000 switching operations
RS485
4800 baud
SELV DC 12 V
1.8 mcd
4mm
940 nm
-10...50ºC
-30...70ºC
Max. 90%, non-condensing
Min. 700hPa (3000m above sea level)
Min. 700hPa (10,000m above sea level)
EN 60950
EN61000-6-3
EN61000-6-2
IP 20 (with mounting box)
III
89/336/EEC
UL/CUL 916
103mm x 52mm x 69mm
Deep flush-mounting box required,
e.g. Siemens5A-002-1
Black
Pantone black 7U2Y
70 g
120 g
4/6
Siemens
Building Technologies
HMR3.1/A – Magnetic card reader
CM2N6334en
31.07.2008
Connection diagrams
Address
switch
Device connection
Read head
5V
GND
DATA CK CP
5V
Microcontroller
RESET
5V
12V
GND
UG
RS485
12V
UR
UP
UN
Door
close
Room bus
Door
open
Guest
in
room
Do
not
disturbe
Pin
Connection
to the room bus
1
2
3
4
Make
up
room
Bell
push
Signal
UP
UN
UG
UR
Data signal +
Data signal –
System neutral (GND)
Supply voltage DC +12 V
Room bus connection terminal
(view of pins from above)
Wiring diagram
S1
S1
Magnetic card reader HMR3.1/A
N1
HRC3.. room controller
6334A01
1 2 3 4
1 2 3 4
X12
N1
STOP
Caution
Note the cross-over between pins 3 and 4.
5/6
Siemens
Building Technologies
HMR3.1/A – Magnetic card reader
CM2N6334en
31.07.2008
Dimensions
Dimensions in mm
ca. 70
1,5
51
67
65
100
102,5
9,5
80,5
Optional:
SIEMENS S.p.A.
5TG9015, 5TG9021-1_*_
Optional:
SIEMENS S.p.A.
5VA002-1
140,5
6/6
Siemens
Building Technologies
© 2005-2008 Siemens Switzerland Ltd.
HMR3.1/A – Magnetic card reader
6234M01
3
108
Subject to change
CM2N6334en
31.07.2008
Download PDF