MOUNTING SYSTEM FOR ON-WALL APPLICATION
Art.No. OWMS_880
applicable for installations up to 59.2kg
INSTALLATION GUIDE
VERY IMPORTANT NOTE
NEVER USE MORE THAN ONE SET ON ONE GLASS!
FOR YOUR SAFETY
Please read all safety information thoroughly before using the product.
Not complying with the instructions provided within this installation guide may
result in severe injuries or life-threatening situations and/or damage respectively
change the product.
Please comply accurately with all warning instructions to ensure proper operation
of the product.
Copyright © 2013 by ad notam. All Rights Reserved.
All brand names, product names and/or trademarks are the property of their respective
owners. This manual, as a whole, in part or excerpts, may not be reproduced, copied,
stored in a data retrieval system or transferred electronically, mechanically or in any other
way, shape or form without prior written authorization by ad notam.
Specifications of the ad notam products are subject to unannounced changes; this manual
may thus not reflect the current technical status.
CONTENTS
PACKAGE INCLUDES.......................................................................................................4
DESCRIPTION...................................................................................................................5
SAFETY INSTRUCTIONS..................................................................................................6
PREPARATION..................................................................................................................7
MOUNTING......................................................................................................................9
3
PACKAGE INCLUDES
Thank you for choosing an ad notam product. Before using the mounting system
please check the following contents of the package for completeness:
OWMS_880
Description
Wall mounting plate (WMP)
dimensions: 880 x 72 x 55mm
Glass mounting plate (GMP)
dimensions: 880 x 104 x 55mm
backside: self adhesive
(may be pre-installed on glass)
Wall locking plate (WLP)
dimensions: 60 x 60 x 49mm
4
Illustration
Amount
1
1
1
Glass locking plate (GLP)
dimensions: 60 x 60 x 27mm
backside: self adhesive
(may be pre-installed on glass)
1
Fixation magnet
diameter: 45mm, depths: 13.7mm
Distance ring
diameter: 45mm, depths: 39mm
2
2
Magnet holder plate
counterpart for the magnets
dimensions: 70 x 70 x 1mm
(may be pre-installed on glass)
2
Flat head locking bolt (M6) for GLP
Countersunk bolt, 100mm
Round head screw for WMP
Round head screw for WLP
Screw anchor
Lock washer for WMP, WLP, GLP
1
2
5
4
11
10
DESCRIPTION
The ad notam on-wall mounting system is designed to install a glass or mirror
surface protruding from the wall. It is qualified even for installations in damp
locations and features a mechanical suspension mechanism at the upper edge
as well as magnetic fixation elements and a locking bolt at the lower edge. The
on-wall mounting system may be combined with a visual cover or LED lighting
elements.
5
SAFETY INSTRUCTIONS
SAFETY INSTRUCTION REGARDING GLASS SURFACE PREPARATION
The glass surface must be clean and dry. Contaminated surfaces should be cleaned
with ad notam’s preferred solvent. A clean lint-free cloth should be used. Use
proper safety precautions for handling solvent.
SAFETY INSTRUCTION REGARDING TAPE PRIMER
Shake tape primer well before using. Apply a thin uniform coating to the glass
surface using the minimum amount that will fully coat the surface. Allow tape primer
to dry thoroughly before applying tape. This is usually accomplished in 5 minutes
at room temperature. Be sure the primed surface remains free from containments
prior to applying the tape. Tape primer can be removed with ad notam’s preferred
solvent. Vigorous scrubbing may be required. Carefully read and follow manufacturer’s
precautions and directions for use when handling cleaning solvents.
SAFETY INSTRUCTION REGARDING SELF-ADHESIVE TAPE
Shelf life: 6 months from day of dispatch by ad notam when stored in the original
carton at 21°C [70°F] and 50% relative humidity.
SAFETY INSTRUCTION REGARDING APPLYING OWMS TO GLASS
Pressure: Bond strength is dependent upon the amount of adhesive-to-surface
contact developed. Firm application pressure develops better adhesive contact
and helps improve bond strength. Typically, good surface contact can be attained
by applying enough pressure to insure that the tape experiences approximately 15
psi (100 kPa) pressure. Either roller or platen pressure can be used. Note that rigid
surfaces may require 2 or 3 times that much pressure to make the tape experience
15 psi.
Temperature: Ideal application temperature range is 21° - 38°C [70° - 100°F]. Initial
tape application to surface at temperatures below 10°C [50°F] is not recommended
because the adhesive becomes too firm to adhere readily. However once properly
applied low temperature holding is generally satisfactory.
Wet out time: After application, the bond strength will increase as the adhesive flows
onto the surface. At room temperature approximately 50% of ultimate bond strength
will be achieved after 20 minutes, 90% after 24 hours and 100% after 72 hours. This
flow is faster at higher temperatures and slower at lower temperatures. Ultimate
bond strength can be achieved more quickly (and in some cases bond strength can
be increased) by exposure of the bond to elevated temperatures (e.g. 66°C [150°F]
for 1 hour). This can provide better adhesive wet out onto the substrates.
6
PREPARATION
REQUIRED TOOLS
oPhillips-tip screwdriver
oAllen wrench
oLevel and measuring tape
oGlass cleaner and clean cloths
oGlass suction cups
GLASS PREPARATION - STANDARD RULE OF ASSEMBLY
The mounting system elements that need to be affixed on the backside of the glass
surface are basically arranged at factory according to a standard rule of assembly:
90mm
3.54“
centered
90mm
3.54“
125mm
4.92“
125mm
4.92“
90mm
3.54“
90mm
3.54“
If you have indicated on the ad notam glass orderform that you wish to receive
the glass without factory-affixed mounting system elements, they should have
been enclosed to your delivery unmounted. In this case please clean the rear side
of the glass surface thoroughly with glass cleaner and/or compressed air before
beginning assembly. Also make sure that you know where top and bottom is.
NOTE
After affixing the self-adhesive mounting elements according to your specification
allow 24 hours drying to ensure perfect adhesion.
WARNING
ad notam declines any liability for installations without factory-affixed mounting
system elements.
7
PREPARATION
CAUTION
Before getting started please notice that ad notam declines any liability for the
screws and screw anchors delivered with the product. These may need to be
replaced at the job site when considering the nature of the load-bearing wall, since
ad notam is not familiar with the construction environment.
NOTE
Use the 100mm countersunk bolts and a distance ring for each fixation magnet.
WALL PREPARATION
Structural measures must be accomplished for an on-wall installation. A specialist
should carry these out.
The following indicated dimensions are only relevant for glasses prepared
according to the standard rule of assembly, see section glass preparation!
Mark the drill holes for the center screw of the wall mounting plate (WMP) and the
fixation magnets considering the desired position of the glass surface on the wall.
The drill hole for the center screw of the WMP should be marked 138mm / 5.43”
below the center of the upper edge of the desired position of the glass surface.
The drill holes for the fixation magnets are supposed to be marked 125mm / 4.92”
from the lower edge and the sides of the desired position of the glass surface.
Then drill the three holes at the marks, mount the anchors and screw the WMP incl.
lock washer as well as the fixation magnets incl. distance rings securely to the wall.
uppe
r edg
e gla
138m
ss su
m/5
125m
rface
.43“
OWMS_880
m/4
.92“
Countersunk bolt 100mm
1 x distance ring 39mm
125m
m/4
125m
.92“
m/4
lowe
r edg
8
e gla
ss su
rface
125m
m/4
.92“
.92“
PREPARATION
Now mark the drill holes for the outer screws of the wall mounting plate on the wall
using a level. Then drill the holes at the marks, mount the anchors and fix the WMP
in place by tightening the five round head screws.
uppe
r edg
e gla
ss su
rface
5 x round head screw
5 x lock washer
5 x anchor
lowe
r edg
e gla
ss su
rface
When all mounting elements are arranged in good order we recommend to add
also the wall locking plate (WLP) in order to secure the glass on the wall. For this
purpose locate the center of the WLP 130mm / 5.12” above the center of the lower
edge of the desired position of the glass surface and mark the four outer drill holes
on the wall. Then drill
the holes at the marks, mount the anchors and fix the WLP
uppe
r edg
incl. lock washers in place
bye gtightening
the round head screws.
lass
surfa
ce
lowe
130m
r edg
m/5
e gla
ss su
rface
.12“
4 x round head screw
4 x lock washer
4 x anchor
9
MOUNTING
When the wall and the glass are prepared, use the suction cups to elevate the glass
in order to let the self-adhesive glass mounting plate (assembled on the upper
backside of the glass) slide-in the wall mounting plate (affixed in the upper
position on the wall). When the slide-in mechanism is locked in place let the
self-adhesive magnet holder plates (assembled on the lower backside of the
glass) snap the fixation magnets (affixed in the lower position on the wall).
NOTE
The edges of the glass are very sensitive. Take care that they do not touch the wall
in any way to avoid damages and split-offs.
Finally screw the locking bolt with a lock washer bottom-up through the glass
locking plate and the wall locking plate in order to secure the glass on the wall.
10
®