built for the long haul. ice systems

ice systems
built
for
the
long
haul.
BUILT FOR TH
Buying an ice machine is a decision you will live
with for a long time. For the money, you want
an ice machine that delivers more performance
for less cost, over a longer period of time. You
want Cornelius.
Efficient Water/Electrical
Compressors and condensers are matched precisely to provide the perfect
balance between water and electrical use. All solid-state circuitry
maximizes reliability.
Improved Serviceability
A self-insulating ABS evaporator housing offers worry-free durability.
Flexible Capacities
22", 27", 30", 44" and 48" cabinet sizes with capacities ranging from 200 to 2,500 lbs. per day.
Future Proof™ Refrigerants
Our ice machines are engineered with Future Proof™, zero ozone depleting
refrigerants.
Limited Lifetime Warranty *
Stainless steel panels and frames are guaranteed against corrosion for life.
*See
warranty for details.
E LONG HAUL.
Self-Insulated
ABS Evaporator
Housing
Programmable Water
Control
Nickel-Plated
Copper Evaporator
Quick-Change
Merchandising Panel
Insulated,
Double-Wall
Bulkhead
Front-Mounted LED
Future Proof R-404a
Refrigerant
In-Line
Water Pump
Exclusive Ice
Harvest System
Microban®
Antimicrobial
Product Protection
Front Serviceable
*See warranty for details.
Series 50†
C
U
B
E
R
S
DIMENSIONS/CAPACITY
Model
Number
Nominal
Capacity
Dimensions
Cabinet
Finish
ACS50
46 lbs.
15"w x 24"d x 34"h
E
Model
Number
Ice Harvest
Rate
lbs. per 24 hrs.
Potable Water
Use
per 100 lbs.
KWH
Consumption
per 100 lbs.
Condenser
Water Use
per 100 lbs.
Capacity
Storage Bin
(lbs.)
ACS50
38
38.5
14.3
n/a
25
ARI CERTIFIED PERFORMANCE
Rated in accordance with ARI Standard 810-91 and 820-88.
34"
PRODUCTION CHART
AIR-COOLED
Water Temperature (˚F)
70
Air Temp (˚F)
50
70
46 lbs.
41 lbs.
40 lbs.
80
80
44 lbs.
40 lbs.
40 lbs.
90
42 lbs.
38 lbs.
35 lbs.
24"
SPECIFICATIONS
OPERATING LIMITS
Model
Refrigerant Standard
Number Condenser
Type
Electrical
15"
ACS50SL Air-Cooled
R-134a
Circuit
Capacity
Maximum
Fuse Size
15
15
115/60/1
Shipping Operating
Ambient
Water
Water
Weight
Weight Temperature Temperature Pressure
110 lbs.
100 lbs.
50°F-100°F
45°F-90°F
Voltage
Range
20-120 psi 110-126
†Limited lifetime warranty not applicable to this model.
ACS50
Series 200
DIMENSIONS/CAPACITY
Model
Number
Nominal
Capacity
Dimensions
Cabinet
Finish
IACS224/IWCS224
251 lbs
24"w x 24"d x 39"h
Polyethylene
IACS227/IWCS227
326 lbs
27"w x 28"d x 39"h
SS
ARI CERTIFIED PERFORMANCE
Model
Number
Ice Harvest
Rate
lbs. per 24 hrs.
Potable Water
Use
per 100 lbs.
KWH
Consumption
per 100 lbs.
39"
Condenser
Water Use
per 100 lbs.
Capacity
Storage Bin
( lbs.)
IACS224
150
25.0
10.6
n/a
77
IWCS224
145
22.0
10.5
195
77
IACS227
240
27.0
9.8
n/a
75
IWCS227
240
27.0
7.6
160
75
Rated in accordance with ARI Standard 810-91 and 820-88.
24"
IACS-224 PRODUCTION CHART
24"
AIR-COOLED
IACS224
Air Temp (˚F)
WATER-COOLED
Water Temperature (˚F)
50
70
80
Water Temperature (˚F)
50
70
80
Air Temp (˚F)
50
251 lbs.
226 lbs.
214 lbs.
50
221 lbs.
179 lbs.
171 lbs.
70
226 lbs.
198 lbs.
177 lbs.
70
218 lbs.
165 lbs.
155 lbs.
90
167 lbs.
150 lbs.
137 lbs.
90
164 lbs.
145 lbs.
130 lbs.
IACS-227 PRODUCTION CHART
AIR-COOLED
39"
Air Temp (˚F)
WATER-COOLED
Water Temperature (˚F)
50
70
80
Water Temperature (˚F)
50
70
80
Air Temp (˚F)
50
326 lbs.
295 lbs.
271 lbs.
50
330 lbs.
300 lbs.
270 lbs.
70
312 lbs.
290 lbs.
267 lbs.
70
310 lbs.
280 lbs.
260 lbs.
90
263 lbs.
240 lbs.
220 lbs.
90
280 lbs.
240 lbs.
230 lbs.
Model
Number
Refrigerant Standard
Condenser
Type
Electrical
Circuit
Capacity
Maximum
Fuse Size
IACS224
Air-Cooled
SPECIFICATIONS
28
"
27 "
IACS227
4
OPERATING LIMITS
Shipping Operating
Ambient
Water
Water
Weight
Weight Temperature Temperature Pressure
Voltage
Range
R-404a
115/60/1
15
15
182 lbs.
146 lbs.
50°F-100°F
45°F-90°F
20-120 psi 110-126
IWCS224 Water-Cooled
R-404a
115/60/1
15
15
182 lbs.
146 lbs.
50°F-100°F
45°F-90°F
20-120 psi 110-126
IACS227
R-404a
115/60/1
20
20
230 lbs.
198 lbs.
50°F-100°F
45°F-90°F
20-120 psi 110-126
R-404a
115/60/1
20
20
230 lbs.
198 lbs.
50°F-100°F
45°F-90°F
20-120 psi 110-126
Air-Cooled
IWCS227 Water-Cooled
Series 322†
DIMENSIONS/CAPACITY
Model
Number
Nominal
Capacity
PLUMBING
Cabinet
Finish
Dimensions
1
3
Water
Inlets/Outlets
AC322
359 lbs.
22"w x 23 ⁄2" d x 16 ⁄8" h
SS
3
WC322
341 lbs.
22"w x 23 1⁄2" d x 16 3⁄8" h
SS
3
Electrical Service
Opening
Drainhose
⁄8 " male flare
⁄8 " male flare
9
9
3
7
⁄16" I.D. x ⁄4 " O.D.
⁄16" I.D. x 3⁄4 " O.D.
⁄8 " diameter hole
⁄8 " diameter hole
7
163⁄8"
397⁄8"
ARI CERTIFIED PERFORMANCE
Model
Number
Ice Harvest
Rate
lbs. per 24 hrs.
Potable Water
Use
per 100 lbs.
KWH
Consumption
per 100 lbs.
Condenser
Water Use
per 100 lbs.
AC322
270
23.9
8.7
n/a
WC322
270
23.9
8.7
170
Rated in accordance with ARI Standard 810-91.
231⁄2"
PRODUCTION CHART
AIR-COOLED
29
"
22 "
WATER-COOLED
Water Temperature (˚F)
50
70
80
Air Temp (˚F)
C
U
B
E
R
S
Water Temperature (˚F)
50
70
80
Air Temp (˚F)
50
359 lbs.
321 lbs.
312 lbs.
50
341 lbs.
300 lbs.
281 lbs.
70
333 lbs.
313 lbs.
277 lbs.
70
326 lbs.
289 lbs.
266 lbs.
90
305 lbs.
270 lbs.
249 lbs.
90
315 lbs.
270 lbs.
251 lbs.
Model
Refrigerant Standard
Number Condenser
Type
Electrical
Circuit
Capacity
AC322/B122AP
SPECIFICATIONS
AC322
Air-Cooled
WC322 Water-Cooled
OPERATING LIMITS
Maximum
Fuse Size
Shipping Operating
Ambient
Water
Water
Weight
Weight Temperature Temperature Pressure
Voltage
Range
R-404a
115/60/1
20
20
138 lbs.
122 lbs.
50°F-100°F
45°F-90°F
20-120 psi 110-126
R-404a
115/60/1
20
20
134 lbs.
118 lbs.
50°F-100°F
45°F-90°F
20-120 psi 110-126
†Limited lifetime warranty does not apply to this model.
Series 300"Xtreme"
DIMENSIONS/CAPACITY
23"
PLUMBING
Model
Number
Nominal
Capacity
Dimensions
Cabinet
Finish
Water
Inlets/Outlets
XAC322
342 lbs.
22"w x 241⁄2"d x 23"h
SS
3
XAC330
342 lbs.
30"w x 241⁄2"d x 23"h
SS
3
XWC322
334 lbs.
22"w x 241⁄2"d x 23"h
SS
XWC330
334 lbs.
30"w x 241⁄2"d x 23"h
SS
⁄8 " male flare
⁄8 " male flare
3
⁄8 " male flare
3
⁄8 " male flare
Electrical Service
Opening
Drainhose
9
⁄16" I.D. x 3⁄4 " O.D.
⁄16" I.D. x 3⁄4 " O.D.
9
⁄16" I.D. x 3⁄4 " O.D.
9
⁄16" I.D. x 3⁄4 " O.D.
9
7
⁄8 " diameter hole
⁄8 " diameter hole
7
⁄8 " diameter hole
7
⁄8 " diameter hole
7
ARI CERTIFIED PERFORMANCE
71"
Model
Number
Ice Harvest
Rate
lbs. per 24 hrs.
Potable Water
Use
per 100 lbs.
KWH
Consumption
per 100 lbs.
Condenser
Water Use
per 100 lbs.
XAC322/XAC330
269
16.7
8.5
n/a
XWC322/XWC330
269
16.7
6.8
149
Rated in accordance with ARI Standard 810-91.
PRODUCTION CHART
AIR-COOLED
Air Temp (˚F)
31 3
⁄
4
WATER-COOLED
Water Temperature (˚F)
50
70
80
Water Temperature (˚F)
50
70
80
Air Temp (˚F)
50
342
326
312
50
334
302
292
70
338
310
304
70
315
287
285
90
285
269
258
90
299
281
268
"
SPECIFICATIONS
22 "
XAC322/XWC322
OPERATING LIMITS
Model
Number
Refrigerant Standard
Condenser
Type
Electrical
XAC322
Air-Cooled
XWC322 Water-Cooled
XAC330
Air-Cooled
XWC330 Water-Cooled
Circuit
Capacity
Maximum
Fuse Size
Shipping Operating
Ambient
Water
Water
Weight
Weight Temperature Temperature Pressure
Voltage
Range
R-404a
115/60/1
20
20
148 lbs.
123 lbs.
50°F-100°F
45°F-90°F
20-80 psi
110-126
R-404a
115/60/1
20
20
144 lbs.
119 lbs.
50°F-100°F
45°F-90°F
20-80 psi
110-126
50°F-100°F
50°F-100°F
45°F-90°F
45°F-90°F
20-80 psi
20-80 psi
110-126
110-126
R-404a
115/60/1
20
20
163 lbs.
136 lbs.
R-404a
115/60/1
20
20
155 lbs.
128 lbs.
5
Series 500"Xtreme"
C
U
B
E
R
S
DIMENSIONS/CAPACITY
Model
Number
23"
Nominal
Capacity
PLUMBING
Cabinet
Finish
Dimensions
1
Water
Inlets/Outlets
XAC522
600 lbs.
22"w x 24 ⁄2"d x 23"h
SS
3
XWC522
600 lbs.
22"w x 241⁄2"d x 23"h
SS
3
XRC522
540 lbs.
22"w x 241⁄2"d x 23"h
SS
XAC530
540 lbs.
30"w x 241⁄2"d x 23"h
SS
XWC530
600 lbs.
30"w x 241⁄2"d x 23"h
SS
XRC530
600 lbs.
30"w x 241⁄2"d x 23"h
SS
⁄8 " male flare
⁄8 " male flare
3
⁄8 " male flare
3
⁄8 " male flare
3
⁄8 " male flare
3
⁄8 " male flare
Electrical Service
Opening
Drainhose
9
9
3
7
⁄16" I.D. x ⁄4 " O.D.
⁄16" I.D. x 3⁄4 " O.D.
9
⁄16" I.D. x 3⁄4 " O.D.
9
⁄16" I.D. x 3⁄4 " O.D.
9
⁄16" I.D. x 3⁄4 " O.D.
9
⁄16" I.D. x 3⁄4 " O.D.
⁄8 " diameter hole
⁄8 " diameter hole
7
⁄8 " diameter hole
7
⁄8 " diameter hole
7
⁄8 " diameter hole
7
⁄8 " diameter hole
7
ARI CERTIFIED PERFORMANCE
61"
Model
Number
Ice Harvest
Rate
lbs. per 24 hrs.
Potable Water
Use
per 100 lbs.
KWH
Consumption
per 100 lbs.
Condenser
Water Use
per 100 lbs.
XAC522/XAC530
475
17.0
6.7
n/a
XWC522/XWC530
475
17.0
5.8
133
XRC522/XRC530
475
17.0
6.7
n/a
Rated in accordance with ARI Standard 810-91.
PRODUCTION CHART
AIR-COOLED
Air Temp (˚F)
32 5
⁄
16
WATER-COOLED
Water Temperature (˚F)
50
70
80
REMOTE AIR-COOLED
Water Temperature (˚F)
50
70
80
Air Temp (˚F)
Water Temperature (˚F)
50
70
80
Air Temp (˚F)
50
600
596
542
50
540
515
489
50
600
596
542
70
597
549
536
70
540
494
475
70
597
549
536
90
513
475
454
90
532
475
454
90
513
475
454
"
30 "
SPECIFICATIONS
XAC522/XAC530
OPERATING LIMITS
Model
Number
Refrigerant Standard
Condenser
Type
Electrical
XAC522
Air-Cooled
Circuit
Capacity
Maximum
Fuse Size
Shipping Operating
Ambient
Water
Water
Weight
Weight Temperature Temperature Pressure
Voltage
Range
R-404a
115/60/1
20
20
162 lbs.
135 lbs.
50°F-100°F
45°F-90°F
20-80 psi
110-126
XWC522 Water-Cooled
XRC522 AC Remote*
R-404a
115/60/1
20
20
145 lbs.
117 lbs.
50°F-100°F
45°F-90°F
20-80 psi
110-126
R-404a
115/60/1
20
20
165 lbs.
141 lbs.
50°F-100°F
45°F-90°F
20-80 psi
110-126
XAC530
R-404a
115/60/1
20
20
170 lbs.
143 lbs.
XWC530 Water-Cooled
R-404a
115/60/1
20
20
153 lbs.
125 lbs.
50°F-100°F
50°F-100°F
45°F-90°F
45°F-90°F
20-80 psi
20-80 psi
110-126
110-126
XRC530 AC Remote*
R-404a
115/60/1
20
20
180 lbs.
149 lbs.
50°F-100°F
45°F-90°F
20-80 psi
110-126
Air-Cooled
* Use Remote Condenser CR-500.
Series 600"Xtreme"
DIMENSIONS/CAPACITY
25"
PLUMBING
Model
Number
Nominal
Capacity
Dimensions
Cabinet
Finish
XAC630
XWC630
XRC630
722 lbs.
671 lbs.
722 lbs.
30"w x 241⁄2" d x 25"h
30"w x 241⁄2" d x 25"h
30"w x 241⁄2" d x 25"h
SS
SS
SS
Water
Inlets/Outlets
Electrical Service
Opening
Drainhose
3
9
7
3
9
7
⁄8 " male flare
⁄8 " male flare
3
⁄8 " male flare
⁄16" I.D. x 3⁄4 " O.D.
⁄16" I.D. x 3⁄4 " O.D.
9
⁄16" I.D. x 3⁄4 " O.D.
⁄8 " diameter hole
⁄8 " diameter hole
7
⁄8 " diameter hole
ARI CERTIFIED PERFORMANCE
73"
Model
Number
Ice Harvest
Rate
lbs. per 24 hrs.
Potable Water
Use
per 100 lbs.
KWH
Consumption
per 100 lbs.
Condenser
Water Use
per 100 lbs.
XAC630
547
16.3
6.9
n/a
XWC630
589
17.4
5.6
116
XRC630
547
16.3
6.9
n/a
Rated in accordance with ARI Standard 810-91.
PRODUCTION CHART
AIR-COOLED
Air Temp (˚F)
32 5⁄
16
"
Air Temp (˚F)
Air Temp (˚F)
Water Temperature (˚F)
50
70
80
722 lbs.
648 lbs.
634 lbs.
50
671 lbs.
603 lbs.
556 lbs.
50
722 lbs.
648 lbs.
634 lbs.
70
672 lbs.
609 lbs.
589 lbs.
70
661 lbs.
594 lbs.
551 lbs.
70
672 lbs.
609 lbs.
589 lbs.
90
606lbs.
547 lbs.
521 lbs.
90
652 lbs.
589 lbs.
542 lbs.
90
606 lbs.
547 lbs.
521 lbs.
SPECIFICATIONS
OPERATING LIMITS
30 "
Standard
Electrical
Circuit Maximum
Capacity Fuse Size
Shipping Operating
Ambient
Water
Water
Weight
Weight Temperature Temperature Pressure
Voltage
Range
XAC630 Air-Cooled
R-404a
208/230/60/1
20
20
201 lbs.
172 lbs.
50°F-100°F
45°F-90°F
20-80 psi
198-253
XWC630 Water-Cooled
R-404a
208/230/60/1
20
20
197 lbs.
168 lbs.
50°F-100°F
45°F-90°F
20-80 psi
198-253
XRC630 AC Remote*
R-404a
208/230/60/1
20
20
209 lbs.
180 lbs.
50°F-100°F
45°F-90°F
20-80 psi
198-253
*Use Remote Condenser CR-800.
6
REMOTE AIR-COOLED
Water Temperature (˚F)
50
70
80
50
Model
Refrigerant
Number Condenser
Type
XAC630/B530AP
WATER-COOLED
Water Temperature (˚F)
50
70
80
Series 800"Xtreme"
30"
DIMENSIONS/CAPACITY
Model
Number
25"
Nominal
Capacity
XAC830
XWC830
XRC830
PLUMBING
Cabinet
Finish
Dimensions
241
771 lbs.
780 lbs.
771 lbs.
30"w x
⁄2" d x 25"h
30"w x 241⁄2" d x 25"h
1
30"w x 24 ⁄2" d x 25"h
Water
Inlets/Outlets
SS
SS
SS
9
3
9
⁄8 " male flare
⁄8 " male flare
3
⁄8 " male flare
Electrical Service
Opening
Drainhose
3
3
7
⁄16" I.D. x ⁄4 " O.D.
⁄16" I.D. x 3⁄4 " O.D.
9
⁄16" I.D. x 3⁄4 " O.D.
⁄8 " diameter hole
⁄8 " diameter hole
⁄8 " diameter hole
7
7
ARI CERTIFIED PERFORMANCE
73"
Model
Number
Ice Harvest
Rate
lbs. per 24 hrs.
Potable Water
Use
per 100 lbs.
KWH
Consumption
per 100 lbs.
Condenser
Water Use
per 100 lbs.
XAC830
666
16.3
6.9
n/a
XWC830
700
17.4
5.6
116
XRC830
666
16.3
6.9
n/a
Rated in accordance with ARI Standard 810-91.
PRODUCTION CHART
AIR-COOLED
32 "
Air Temp (˚F)
42 "
WATER-COOLED
Water Temperature (˚F)
50
70
80
REMOTE AIR-COOLED
Water Temperature (˚F)
50
70
80
Air Temp (˚F)
C
U
B
E
R
S
Water Temperature (˚F)
50
70
80
Air Temp (˚F)
50
771 lbs.
752 lbs.
740 lbs.
50
780 lbs.
742 lbs.
715 lbs.
50
771 lbs.
752 lbs.
740 lbs.
70
747 lbs.
730 lbs.
712 lbs.
70
761 lbs.
724 lbs.
693 lbs.
70
747 lbs.
730 lbs.
712 lbs.
90
703 lbs.
666 lbs.
621 lbs.
90
736 lbs.
700 lbs.
676 lbs.
90
703 lbs.
666 lbs.
621 lbs.
XAC830/B842SS
SPECIFICATIONS
Model
Refrigerant
Number Condenser
Type
XAC830
Air-Cooled
OPERATING LIMITS
Standard
Electrical
Circuit Maximum
Capacity Fuse Size
Shipping Operating
Ambient
Water
Water
Weight
Weight Temperature Temperature Pressure
Voltage
Range
R-404a
208/230/60/1
20
20
211 lbs.
182 lbs.
50°F-100°F
45°F-90°F
20-80 psi
198-253
XWC830 Water-Cooled
R-404a
208/230/60/1
20
20
207 lbs.
178 lbs.
50°F-100°F
45°F-90°F
20-80 psi
198-253
XRC830 AC Remote*
R-404a
208/230/60/1
20
20
223 lbs.
194 lbs.
50°F-100°F
45°F-90°F
20-80 psi
198-253
*Use Remote Condenser CR-800.
Series 1000"Xtreme"
DIMENSIONS/CAPACITY
Model
Number
30"
Nominal
Capacity
XAC1030
XWC1030
XRC1030
PLUMBING
Cabinet
Finish
Dimensions
950 lbs.
959 lbs.
950 lbs.
30"w x 25" d x 25"h
30"w x 25" d x 25"h
30"w x 25" d x 25"h
Water
Inlets/Outlets
9
3
9
⁄8 " male flare
⁄8 " male flare
3
⁄8 " male flare
SS
SS
SS
Electrical Service
Opening
Drainhose
3
3
⁄16" I.D. x ⁄4 " O.D.
⁄16" I.D. x 3⁄4 " O.D.
9
⁄16" I.D. x 3⁄4 " O.D.
7
⁄8 " diameter hole
⁄8 " diameter hole
⁄8 " diameter hole
7
7
25"
ARI CERTIFIED PERFORMANCE
73"
Model
Number
Ice Harvest
Rate
lbs. per 24 hrs.
Potable Water
Use
per 100 lbs.
KWH
Consumption
per 100 lbs.
Condenser
Water Use
per 100 lbs.
XAC1030
830
13.2
7.0
n/a
XWC1030
887
13.2
5.5
112.7
XRC1030
830
13.2
7.0
n/a
Rated in accordance with ARI Standard 810-91.
PRODUCTION CHART
AIR-COOLED
Air Temp (˚F)
32 "
48 "
XAC1030/B1048SS
WATER-COOLED
Water Temperature (˚F)
50
70
80
REMOTE AIR-COOLED
Water Temperature (˚F)
50
70
80
Air Temp (˚F)
Air Temp (˚F)
Water Temperature (˚F)
50
70
80
50
950 lbs.
901 lbs.
890 lbs.
50
959 lbs.
916 lbs.
873 lbs.
50
950 lbs.
901 lbs.
890 lbs.
70
918 lbs.
877 lbs.
860 lbs.
70
939 lbs.
904 lbs.
869 lbs.
70
918 lbs.
877 lbs.
860 lbs.
90
854 lbs.
830 lbs.
799 lbs.
90
900 lbs.
887 lbs.
861 lbs.
90
854 lbs.
830 lbs.
799 lbs.
SPECIFICATIONS
Model
Refrigerant
Number Condenser
Type
Standard
Electrical
OPERATING LIMITS
Circuit Maximum
Capacity Fuse Size
Shipping Operating
Ambient
Water
Water
Weight
Weight Temperature Temperature Pressure
Voltage
Range
XAC1030 Air-Cooled
R-404a
208/230/60/1
20
20
226 lbs.
197 lbs.
50°F-100°F
45°F-90°F
20-80 psi
198-253
XWC1030 Water-Cooled
R-404a
208/230/60/1
20
20
215 lbs.
186 lbs.
50°F-100°F
45°F-90°F
20-80 psi
198-253
XRC1030 AC Remote*
R-404a
208/230/60/1
20
20
225 lbs.
196 lbs.
50°F-100°F
45°F-90°F
20-80 psi
198-253
*Use Remote Condenser CR-1200.
7
C
U
B
E
R
S
Series 1200"Xtreme"
DIMENSIONS/CAPACITY
30"
Nominal
Capacity
Dimensions
XAC1230
XWC1230
XRC1230
1177 lbs.
1062 lbs.
1177 lbs.
30"w x 241⁄2" d x 28"h
30"w x 241⁄2" d x 25"h
30"w x 241⁄2" d x 25"h
25” (water / remote
cooled)
28" (air-cooled)
76"
PLUMBING
Model
Number
Cabinet
Finish
Water
Inlets/Outlets
3
⁄8 " male flare
3
⁄8 " male flare
3
⁄8 " male flare
SS
SS
SS
Electrical Service
Opening
Drainhose
9
⁄16" I.D. x 3⁄4 " O.D.
9
⁄16" I.D. x 3⁄4 " O.D.
9
⁄16" I.D. x 3⁄4 " O.D.
7
⁄8 " diameter hole
⁄8 " diameter hole
7
⁄8 " diameter hole
7
ARI CERTIFIED PERFORMANCE
Model
Number
Ice Harvest
Rate
lbs. per 24 hrs.
Potable Water
Use
per 100 lbs.
KWH
Consumption
per 100 lbs.
Condenser
Water Use
per 100 lbs.
XAC1230
1019
14.6
6.5
n/a
XWC1230
1029
14.6
5.2
79.8
XRC1230
1019
14.6
6.5
n/a
Rated in accordance with ARI Standard 810-91.
PRODUCTION CHART
AIR-COOLED
Air Temp (˚F)
32 "
48 "
WATER-COOLED
Water Temperature (˚F)
50
70
80
REMOTE AIR-COOLED
Air Temp (˚F)
Water Temperature (˚F)
50
70
80
Air Temp (˚F)
Water Temperature (˚F)
50
70
80
50
1177 lbs. 1137 lbs.
1070 lbs.
50
1062 lbs. 1055 lbs. 1042 lbs.
50
1177 lbs.
1137 lbs. 1070 lbs.
70
1143 lbs. 1098 lbs.
1039 lbs.
70
1059 lbs. 1046 lbs. 1027 lbs.
70
1143 lbs.
1098 lbs. 1039 lbs.
90
1076 lbs. 1019 lbs.
977 lbs.
90
1052 lbs. 1029 lbs. 1006 lbs.
90
1076 lbs.
1019 lbs.
SPECIFICATIONS
XAC1230/B1048SS
Model
Number
Refrigerant
Condenser
Type
977 lbs.
OPERATING LIMITS
Standard
Electrical
Circuit
Capacity
Maximum Shipping Operating
Ambient
Water
Water
Fuse Size Weight
Weight Temperature Temperature Pressure
Voltage
Range
XAC1230 Air-Cooled
R-404a
208-230/60/1
20
20
258 lbs.
229 lbs.
50°F-100°F
45°F-90°F
20-80 psi
198-253
XWC1230 Water-Cooled
R-404a
208-230/60/1
20
20
234 lbs.
205 lbs.
50°F-100°F
45°F-90°F
20-80 psi
198-253
XRC1230 AC Remote*
R-404a
208-230/60/1
20
20
247 lbs.
218 lbs.
50°F-100°F
45°F-90°F
20-80 psi
198-253
*Use Remote Condenser CR-1200.
Series 1400"Xtreme"
DIMENSIONS/CAPACITY
Model
Number
Nominal
Capacity
XAC1444
XWC1444
XRC1444
PLUMBING
Cabinet
Finish
Dimensions
3
44"w x 24 ⁄4" d x 25"h
44"w x 243⁄4" d x 25"h
44"w x 243⁄4" d x 25"h
1630 lbs.
1505 lbs.
1630 lbs.
SS
SS
SS
Water
Inlets/Outlets
9
3
9
⁄8 " male flare
⁄8 " male flare
3
⁄8 " male flare
Electrical Service
Opening
Drainhose
3
3
⁄16" I.D. x ⁄4 " O.D.
⁄16" I.D. x 3⁄4 " O.D.
9
⁄16" I.D. x 3⁄4 " O.D.
7
⁄8 " diameter hole
⁄8 " diameter hole
⁄8 " diameter hole
7
7
25"
ARI CERTIFIED PERFORMANCE
Model
Number
Ice Harvest
Rate
lbs. per 24 hrs.
Potable Water
Use
per 100 lbs.
KWH
Consumption
per 100 lbs.
Condenser
Water Use
per 100 lbs.
XAC1444
1275
14.3
6.8
n/a
XWC1444
1374
14.3
5.5
130
XRC1444
1275
14.3
6.8
n/a
73"
Rated in accordance with ARI Standard 810-91.
PRODUCTION CHART
AIR-COOLED
Air Temp (˚F)
32
"
44"
XAC1444/B1048SS
REMOTE AIR-COOLED
Air Temp (˚F)
Water Temperature (˚F)
50
70
80
Air Temp (˚F)
Water Temperature (˚F)
50
70
80
50
1630 lbs. 1505 lbs.
1470 lbs.
50
1505 lbs. 1391 lbs. 1362 lbs.
50
1630 lbs.
1505 lbs. 1470 lbs.
70
1537 lbs. 1416 lbs.
1380 lbs.
70
1473 lbs. 1385 lbs. 1346 lbs.
70
1537 lbs.
1416 lbs. 1380 lbs.
90
1340 lbs. 1275 lbs.
1198 lbs.
90
1409 lbs. 1374 lbs. 1315 lbs.
90
1340 lbs.
1275 lbs. 1198 lbs.
SPECIFICATIONS
Model
Refrigerant
Number Condenser
Type
Standard
Electrical
OPERATING LIMITS
Circuit
Capacity
Maximum Shipping Operating
Ambient
Water
Water
Fuse Size Weight
Weight Temperature Temperature Pressure
Voltage
Range
XAC1444 Air-Cooled
R-404a
208/230/60/1
30
30
317 lbs.
274 lbs.
50°F-100°F
45°F-90°F
20-80 psi
198-253
XWC1444 Water-Cooled
R-404a
208/230/60/1
30
30
295 lbs.
252 lbs.
50°F-100°F
45°F-90°F
20-80 psi
198-253
XRC1444 AC Remote*
R-404a
208/230/60/1
30
30
308 lbs.
265 lbs.
50°F-100°F
45°F-90°F
20-80 psi
198-253
*Use Remote Condenser CR-1400.
8
WATER-COOLED
Water Temperature (˚F)
50
70
80
Series 1800"Xtreme"
DIMENSIONS/CAPACITY
PLUMBING
Model
Number
Nominal
Capacity
Dimensions
Cabinet
Finish
XAC1844
XWC1844
XRC1844
1947 lbs.
1700 lbs.
1947 lbs.
44"w x 243⁄4" d x 25"h
44"w x 243⁄4" d x 25"h
44"w x 243⁄4" d x 25"h
SS
SS
SS
Water
Inlets/Outlets
Electrical Service
Opening
Drainhose
3
9
7
3
9
7
⁄8 " male flare
⁄8 " male flare
3
⁄8 " male flare
⁄16" I.D. x 3⁄4 " O.D.
⁄16" I.D. x 3⁄4 " O.D.
9
⁄16" I.D. x 3⁄4 " O.D.
⁄8 " diameter hole
⁄8 " diameter hole
7
⁄8 " diameter hole
25"
ARI CERTIFIED PERFORMANCE
Model
Number
Ice Harvest
Rate
lbs. per 24 hrs.
Potable Water
Use
per 100 lbs.
KWH
Consumption
per 100 lbs.
Condenser
Water Use
per 100 lbs.
XAC1844
1600
14.5
7.3
n/a
XWC1844
1610
14.5
6.0
150
XRC1844
1600
14.5
7.3
n/a
73"
Rated in accordance with ARI Standard 810-91.
PRODUCTION CHART
AIR-COOLED
Air Temp (˚F)
32
"
44"
WATER-COOLED
Water Temperature (˚F)
50
70
80
C
U
B
E
R
S
REMOTE AIR-COOLED
Air Temp (˚F)
Water Temperature (˚F)
50
70
80
Air Temp (˚F)
Water Temperature (˚F)
50
70
80
50
1947 lbs. 1637 lbs.
1328 lbs.
50
1700 lbs. 1650 lbs. 1610 lbs.
50
1947 lbs.
1637 lbs.
70
1928 lbs. 1619 lbs.
1309 lbs.
70
1660 lbs.
1630lbs. 1580 lbs.
70
1928 lbs.
1619 lbs. 1309 lbs.
1328 lbs
90
1909 lbs. 1600 lbs.
1290 lbs.
90
1640 lbs. 1610 lbs. 1550 lbs.
90
1909 lbs.
1600 lbs. 1290 lbs.
XAC1844/B1048SS
SPECIFICATIONS
Model
Refrigerant
Number Condenser
Type
OPERATING LIMITS
Standard
Electrical
Circuit
Capacity
Maximum Shipping Operating
Ambient
Water
Water
Fuse Size Weight
Weight Temperature Temperature Pressure
Voltage
Range
XAC1844 Air-Cooled
R-404a
208/230/60/1
30
30
367 lbs.
324 lbs.
50°F-100°F
45°F-90°F
20-80 psi
198-253
XWC1844 Water-Cooled
R-404a
208/230/60/1
30
30
345 lbs.
302 lbs.
50°F-100°F
45°F-90°F
20-80 psi
198-253
XRC1844 AC Remote*
R-404a
208/230/60/1
30
30
358 lbs.
315 lbs.
50°F-100°F
45°F-90°F
20-80 psi
198-253
*Use Remote Condenser CR-2400.
Series 2448
DIMENSIONS/CAPACITY
Model
Number
Nominal
Capacity
Dimensions
Cabinet
Finish
IRC2448
IRC2448-3PH
IWC2448
2460 lbs.
2460 lbs.
2534 lbs.
48w x 231⁄2" d x 28"h
48w x 231⁄2" d x 28"h
48w x 231⁄2" d x 28"h
SS
SS
SS
ARI CERTIFIED PERFORMANCE
Model
Number
Ice Harvest
Rate
lbs. per 24 hrs.
Potable Water
Use
per 100 lbs.
KWH
Consumption
per 100 lbs.
Condenser
Water Use
per 100 lbs.
n/a
28"
76"
IRC2448
2024
15.0
8.0
IRC2448-3PH
2024
15.0
8.0
n/a
IWC2448
2200
15.0
6.0
135
PRODUCTION CHART
48"
REMOTE AIR-COOLED
REMOTE WATER-COOLED
Air Temp (˚F)
Water Temperature (˚F)
50
70
80
Air Temp (˚F)
Water Temperature (˚F)
50
70
80
50
2460 lbs. 2288 lbs. 2224 lbs.
50
2534 lbs. 2240 lbs. 2138 lbs.
70
2401 lbs. 2244 lbs. 2186 lbs.
70
2500 lbs. 2221 lbs. 2096 lbs.
90
2163 lbs. 2024 lbs. 1938 lbs.
90
2283 lbs. 2200 lbs. 2057 lbs.
32
"
48"
SPECIFICATIONS
IRC2448/B1048SS
OPERATING LIMITS
Model
Number
Condenser
IRC2448
AC Remote*
R-404a
208-230/60/1
30
30
396 lbs.
335 lbs.
50°F-100°F
50°F-90°F
20-120 psi 198-235
IRC2448-3PH AC Remote*
R-404a
208-230/60/3
30
30
396 lbs.
335 lbs.
50°F-100°F
50°F-90°F
20-120 psi 198-235
R-404a
208-230/60/1
30
30
388 lbs.
327 lbs.
50°F-100°F
50°F-90°F
20-120 psi 198-235
IWC2448
Water-Cooled
Refrigerant Standard Circuit Maximum Shipping Operating Ambient
Water
Water Voltage
Type
Electrical Capacity Fuse Size Weight
Weight Temperature Temperature Pressure Range
C
H
U
N
K
L
E
T
S
*Use Remote Condenser CR-2400.
9
141⁄2 "
Series 500
DIMENSIONS/CAPACITY
Model
Number
Nominal
Capacity
PLUMBING
Cabinet
Finish
Dimensions
WCC-500A
391 lbs.
141⁄2"w x 25"d x 241⁄2"h
SS
WCC-500W
391 lbs.
141⁄2"w x 25"d x 241⁄2"h
SS
Water
Inlets/Outlets
Electrical Service
Opening
Drainhose
1
⁄4 " male flare
⁄4 " MF / 3⁄8" FPT
⁄8" I.D. x 9⁄16 " O.D.
⁄8" I.D. x 9⁄16 " O.D.
1
3
7
3
7
⁄8 " diameter hole
⁄8 " diameter hole
PRODUCTION CHART
721⁄2 "
AIR-TEMPERATURE
WATER-TEMPERATURE
50ºF
70ºF
80ºF
50ºF
391 lbs.
351 lbs.
330 lbs.
70ºF
369 lbs.
329 lbs.
310 lbs.
90ºF
317 lbs.
285 lbs.
271 lbs.
SPECIFICATIONS
Model
Number
Condenser
WCC-500A
Air-Cooled
OPERATING LIMITS
Refrigerant Standard Circuit Maximum Shipping Operating
Ambient
Water
Water
Type
Electrical Capacity Fuse Size Weight
Weight Temperature Temperature Pressure
WCC-500W Water-Cooled
Voltage
Range
R-404a
115/60/1
15
15
154 lbs.
142 lbs.
50°F-100°F
50°F-90°F
20-120 psi 110-126
R-404a
115/60/1
15
15
154 lbs.
142 lbs.
50°F-100°F
50°F-90°F
20-120 psi 110-126
"
5 16
⁄
32
C
H
U
N
K
L
E
T
S
241⁄2 "
30"
Series 700
WCC500/B530SS
141⁄2 "
DIMENSIONS/CAPACITY
Model
Number
241⁄2 "
Nominal
Capacity
PLUMBING
Dimensions
Cabinet
Finish
WCC-700A
636 lbs.
141⁄2"w x 25"d x 241⁄2"h
SS
WCC-700W
636 lbs.
141⁄2"w x 25"d x 241⁄2"h
SS
WCC-700R
636 lbs.
141⁄2"w x 25"d x 241⁄2"h
SS
Water
Inlets/Outlets
Electrical Service
Opening
Drainhose
1
⁄4 " male flare
⁄4 " MF / 3⁄8" FPT
1
⁄4 " male flare
⁄8" I.D. x 9⁄16 " O.D.
⁄8" I.D. x 9⁄16 " O.D.
3
⁄8" I.D. x 9⁄16 " O.D.
1
3
7
3
7
⁄8 " diameter hole
⁄8 " diameter hole
7
⁄8 " diameter hole
PRODUCTION CHART
AIR-TEMPERATURE
1
72 ⁄2 "
WATER-TEMPERATURE
50ºF
70ºF
80ºF
50ºF
636 lbs.
570 lbs.
536 lbs.
70ºF
616 lbs.
550 lbs.
518 lbs.
90ºF
570 lbs.
513 lbs.
489 lbs.
SPECIFICATIONS
Model
Number
Condenser
WCC-700A
Air-Cooled
Refrigerant
Type
WCC-700W Water-Cooled
Circuit Maximum Shipping Operating
Ambient
Water
Water
Capacity Fuse Size Weight
Weight Temperature Temperature Pressure
Voltage
Range
R-404a
115/60/1
20
20
163 lbs.
152 lbs.
50°F-100°F
50°F-90°F
20-120 psi 110-126
R-404a
115/60/1
20
20
163 lbs.
152 lbs.
50°F-100°F
50°F-90°F
20-120 psi 110-126
20-120 psi 110-126
"
32
WCC-700R*
AC Remote
R-404a
115/60/1
20
20
138 lbs.
126 lbs.
50°F-100°F
50°F-90°F
WCC-701A
Air-Cooled
R-404a
208-230/60/1
20
20
163 lbs.
152 lbs.
50°F-100°F
50°F-90°F
20-120 psi 198-253
R-404a
208-230/60/1
20
20
163 lbs.
152 lbs.
50°F-100°F
50°F-90°F
20-120 psi 198-253
WCC-701W Water-Cooled
42"
OPERATING LIMITS
Standard
Electrical
*Use Remote Condenser WCU.
WCC700/B842SS
Series 1000
22"
DIMENSIONS/CAPACITY
27"
PLUMBING
Model
Number
Nominal
Capacity
Dimensions
Cabinet
Finish
WCC-1001A
1015 lbs.
22"w x 24"d x 27"h
SS
WCC-1001W
1015 lbs.
22"w x 24"d x 27"h
SS
WCC-1001R
1015 lbs.
22"w x 24"d x 27"h
SS
Water
Inlets/Outlets
1
⁄4 " male flare
⁄4 " MF / 3⁄8" FPT
1
⁄4 " male flare
1
3
7
3
⁄8" I.D. x 9⁄16 " O.D.
⁄8" I.D. x 9⁄16 " O.D.
3
⁄8" I.D. x 9⁄16 " O.D.
7
⁄8 " diameter hole
⁄8 " diameter hole
7
⁄8 " diameter hole
PRODUCTION CHART
75"
AIR-TEMPERATURE
WATER-TEMPERATURE
50ºF
70ºF
80ºF
50ºF
1015 lbs.
909 lbs.
856 lbs.
70ºF
940 lbs.
839 lbs.
790 lbs.
90ºF
831 lbs.
748 lbs.
711 lbs.
SPECIFICATIONS
"
32
10
Electrical Service
Opening
Drainhose
48"
WCC1001/B1048SS
Model
Number
WCC-1001A
OPERATING LIMITS
Condenser
Refrigerant
Type
Standard
Electrical
Air-Cooled
Circuit Maximum Shipping Operating
Ambient
Water
Water
Capacity Fuse Size Weight
Weight Temperature Temperature Pressure
Voltage
Range
R-404a
208-230/60/1
15
15
210 lbs.
194 lbs.
50°F-100°F
50°F-90°F
20-120 psi 198-253
WCC-1001W Water-Cooled
R-404a
208-230/60/1
15
15
210 lbs.
194 lbs.
50°F-100°F
50°F-90°F
20-120 psi 198-253
WCC-1001R* AC Remote
R-404a
208-230/60/1
15
15
210 lbs.
194 lbs.
50°F-100°F
50°F-90°F
20-120 psi 198-253
*Use Remote Condenser WC1.
Series 2000
30"
DIMENSIONS/CAPACITY
28"
PLUMBING
Model
Number
Nominal
Capacity
Dimensions
Cabinet
Finish
WCC-2001A
1999 lbs.
30"w x 24"d x 28"h
SS
WCC-2001W
1999 lbs.
30"w x 24"d x 28"h
SS
WCC-2001R
1999 lbs.
30"w x 24"d x 28"h
SS
Water
Inlets/Outlets
Electrical Service
Opening
Drainhose
1
⁄4 " male flare
⁄4 " MF / 3⁄8" FPT
1
⁄4 " male flare
⁄8" I.D. x 9⁄16 " O.D.
⁄8" I.D. x 9⁄16 " O.D.
3
⁄8" I.D. x 9⁄16 " O.D.
1
3
7
3
7
⁄8 " diameter hole
⁄8 " diameter hole
7
⁄8 " diameter hole
PRODUCTION CHART
76"
AIR-TEMPERATURE
WATER-TEMPERATURE
50ºF
70ºF
80ºF
50ºF
1999 lbs.
1790 lbs.
1684 lbs.
70ºF
1735 lbs.
1549 lbs.
1458 lbs.
90ºF
1403 lbs.
1262 lbs.
1201 lbs.
SPECIFICATIONS
32
"
48"
Model
Number
Condenser
WCC-2001A
Air-Cooled
OPERATING LIMITS
Refrigerant
Type
Standard
Electrical
Circuit Maximum Shipping Operating
Ambient
Water
Water
Capacity Fuse Size Weight
Weight Temperature Temperature Pressure
Voltage
Range
R-404a
208-230/60/1
15
15
342 lbs.
317 lbs.
50°F-100°F
50°F-90°F
20-120 psi 198-253
WCC-2001W Water-Cooled
R-404a
208-230/60/1
15
15
342 lbs.
317 lbs.
50°F-100°F
50°F-90°F
20-120 psi 198-253
WCC-2001R* AC Remote
R-404a
208-230/60/1
15
15
342 lbs.
317 lbs.
50°F-100°F
50°F-90°F
20-120 psi 198-253
*Use Remote Condenser CR-1200.
WCC2001/B1048SS
C
H
U
N
K
L
E
T
S
Series 200 & Series 525
DIMENSIONS/CAPACITY
Model
Number
Nominal
Capacity
AF200PSCR
PLUMBING
Dimensions
1
25"w x 26 ⁄2"d x 40"h
219 lbs.
Cabinet
Finish
Bin Capacity
E or SS
75 lbs.
Water
Inlets/Outlets
Drainhose
1
5
⁄8" O.D. x 1⁄2" O.D.
⁄4" male flare
40"
PRODUCTION CHART
AIR-TEMPERATURE
26 1
⁄
2
WATER-TEMPERATURE
50ºF
70ºF
80ºF
50ºF
219 lbs.
188 lbs.
175 lbs.
70ºF
208 lbs.
174 lbs.
166 lbs.
90ºF
161 lbs.
130 lbs.
117 lbs.
SPECIFICATIONS
"
25 "
Model
Number
AF200PSCR Air-Cooled
AF200PSCR
OPERATING LIMITS
Refrigerant Standard
Condenser
Type
Electrical
R-404a
Circuit
Capacity
Maximum
Fuse Size
15
15
115/60/1
Shipping Operating
Ambient
Water
Water
Voltage
Weight
Weight
Temperature Temperature Pressure Range
220 lbs.
190 lbs.
DIMENSIONS/CAPACITY
Model
Number
AF525PSCR
Nominal
Capacity
654 lbs.
50°F-90°F
20-120 psi 110-126
PLUMBING
Cabinet
Finish
Dimensions
3
50°F-100°F
1
38 ⁄4"w x 26 ⁄2"d x 40"h
E or SS
Bin Capacity
Water
Inlets/Outlets
Condensate
Drain
3
1
⁄8" male flare
175 lbs.
Bin Drain
3
⁄2" O.D. tube
⁄4" FPT
PRODUCTION CHART
40"
AIR-TEMPERATURE
WATER-TEMPERATURE
50ºF
70ºF
80ºF
50ºF
654 lbs.
588 lbs.
552 lbs.
70ºF
639 lbs.
563 lbs.
521 lbs.
90ºF
562 lbs.
479 lbs.
448 lbs.
F
L
A
K
E
R
S
1 2
⁄
26
"
SPECIFICATIONS
3
38 ⁄4 "
Model
Number
OPERATING LIMITS
Refrigerant Standard Circuit Maximum Shipping Operating
Ambient
Water
Water Voltage
Condenser
Type
Electrical Capacity Fuse Size Weight
Weight Temperature Temperature Pressure Range
AF525PSCR Air-Cooled
R-404a
115/60/1
20
20
282 lbs.
240 lbs.
50°F-100°F
50°F-90°F
20-120 psi 110-126
AF525PSCR
11
Series 725
DIMENSIONS/CAPACITY
Model
Number
40"
Nominal
Capacity
AF725PSCR
PLUMBING
Cabinet
Finish
Dimensions
654 lbs.
48"w x 30"d x 40"h
Bin Capacity
E or SS
Water
Inlets/Outlets
Condensate
Drain
3
1
⁄8" male flare
300 lbs.
Bin Drain
3
⁄2" O.D. tube
⁄4" FPT
PRODUCTION CHART
AIR-TEMPERATURE
WATER-TEMPERATURE
50ºF
70ºF
80ºF
50ºF
654 lbs.
588 lbs.
552 lbs.
70ºF
639 lbs.
563 lbs.
521 lbs.
90ºF
562 lbs.
479 lbs.
448 lbs.
"
30
F
L
A
K
E
R
S
48 "
AF725PSCR
SPECIFICATIONS
141⁄2 "
Model
Number
OPERATING LIMITS
Refrigerant Standard Circuit
Condenser
Type
Electrical Capacity
AF725PSCR Air-Cooled
R-404a
115/60/1
Maximum Shipping Operating
Ambient
Water
Water
Voltage
Fuse Size Weight
Weight
Temperature Temperature Pressure Range
20
20
334 lbs.
300 lbs.
50°F-100°F
50°F-90°F
20-120 psi 110-126
241⁄2 "
Series 500
DIMENSIONS/CAPACITY
Model
Number
Nominal
Capacity
PLUMBING
Dimensions
Cabinet
Finish
WCF-510A
460 lbs.
141⁄2"w x 25"d x 241⁄2"h
SS
WCF-510W
460 lbs.
141⁄2"w x 25"d x 241⁄2"h
SS
721⁄2 "
Water
Inlets/Outlets
1
⁄4 " male flare
⁄4 " MF / 3⁄8" FPT
1
Electrical Service
Opening
Drainhose
3
7
3
⁄8" I.D. x 9⁄16 " O.D.
⁄8" I.D. x 9⁄16 " O.D.
7
⁄8 " diameter hole
⁄8 " diameter hole
PRODUCTION CHART
AIR-TEMPERATURE
WATER-TEMPERATURE
50ºF
70ºF
80ºF
50ºF
460 lbs.
412 lbs.
388 lbs.
70ºF
442 lbs.
394 lbs.
371 lbs.
90ºF
407 lbs.
367 lbs.
349 lbs.
SPECIFICATIONS
Model
Number
Condenser
WCF-510A
Air-Cooled
OPERATING LIMITS
Refrigerant Standard Circuit Maximum Shipping Operating
Ambient
Water
Water
Type
Electrical Capacity Fuse Size Weight
Weight Temperature Temperature Pressure
R-404a
115/60/1
15
15
154 lbs.
142 lbs.
50°F-100°F
50°F-90°F
20-120 psi 110-126
R-404a
115/60/1
15
15
154 lbs.
142 lbs.
50°F-100°F
50°F-90°F
20-120 psi 110-126
"
5 16
⁄
32
WCF-510W Water-Cooled
Voltage
Range
30"
Series 700
WCF510/B530SS
141⁄2 "
DIMENSIONS/CAPACITY
Model
Number
241⁄2 "
Nominal
Capacity
PLUMBING
Cabinet
Finish
Dimensions
1
1
WCF-710A
936 lbs.
14 ⁄2"w x 25"d x 24 ⁄2"h
SS
WCF-710W
936 lbs.
141⁄2"w x 25"d x 241⁄2"h
SS
WCF-710R
936 lbs.
141⁄2"w x 25"d x 241⁄2"h
SS
Water
Inlets/Outlets
1
⁄4 " male flare
⁄4 " MF / 3⁄8" FPT
1
⁄4 " male flare
1
Electrical Service
Opening
Drainhose
3
9
⁄8" I.D. x ⁄16 " O.D.
⁄8" I.D. x 9⁄16 " O.D.
3
⁄8" I.D. x 9⁄16 " O.D.
3
7
⁄8 " diameter hole
⁄8 " diameter hole
7
⁄8 " diameter hole
7
PRODUCTION CHART
AIR-TEMPERATURE
1
72 ⁄2 "
WATER-TEMPERATURE
50ºF
70ºF
80ºF
50ºF
936 lbs.
838 lbs.
789 lbs.
70ºF
892 lbs.
796 lbs.
750 lbs.
90ºF
779 lbs.
701 lbs.
667 lbs.
SPECIFICATIONS
Model
Number
Condenser
WCF-710A
Air-Cooled
Refrigerant
Type
WCF-710W Water-Cooled
"
32
42"
WCF710/B842SS
Circuit Maximum Shipping Operating
Ambient
Water
Water
Capacity Fuse Size Weight
Weight Temperature Temperature Pressure
Voltage
Range
R-404a
115/60/1
20
20
163 lbs.
152 lbs.
50°F-100°F
50°F-90°F
20-120 psi 110-126
R-404a
115/60/1
20
20
163 lbs.
152 lbs.
50°F-100°F
50°F-90°F
20-120 psi 110-126
20-120 psi 110-126
WCF-710R*
AC Remote
R-404a
115/60/1
20
20
138 lbs.
126 lbs.
50°F-100°F
50°F-90°F
WCF-710A
Air-Cooled
R-404a
208-230/60/1
20
20
163 lbs.
152 lbs.
50°F-100°F
50°F-90°F
20-120 psi 198-253
R-404a
208-230/60/1
20
20
163 lbs.
152 lbs.
50°F-100°F
50°F-90°F
20-120 psi 198-253
WCF-710W Water-Cooled
*Use Remote Condenser WCU.
12
OPERATING LIMITS
Standard
Electrical
Series 1000
22"
DIMENSIONS/CAPACITY
27"
PLUMBING
Model
Number
Nominal
Capacity
Dimensions
Cabinet
Finish
WCF-1101A
1559 lbs.
22"w x 24"d x 27"h
SS
WCF-1101W
1559 lbs.
22"w x 24"d x 27"h
SS
WCF-1101R
1559 lbs.
22"w x 24"d x 27"h
SS
Water
Inlets/Outlets
1
⁄4 " male flare
⁄4 " MF / 3⁄8" FPT
1
⁄4 " male flare
1
Electrical Service
Opening
Drainhose
3
7
3
⁄8" I.D. x 9⁄16 " O.D.
⁄8" I.D. x 9⁄16 " O.D.
3
⁄8" I.D. x 9⁄16 " O.D.
7
⁄8 " diameter hole
⁄8 " diameter hole
7
⁄8 " diameter hole
PRODUCTION CHART
75"
AIR-TEMPERATURE
WATER-TEMPERATURE
50ºF
70ºF
80ºF
50ºF
1559 lbs.
1396 lbs.
1314 lbs.
70ºF
1426 lbs.
1273 lbs.
1198 lbs.
90ºF
1260 lbs.
1134 lbs.
1079 lbs.
SPECIFICATIONS
"
32
48"
Model
Number
Condenser
WCF-1101A
Air-Cooled
OPERATING LIMITS
Refrigerant
Type
Standard
Electrical
Circuit Maximum Shipping Operating
Ambient
Water
Water
Capacity Fuse Size Weight
Weight Temperature Temperature Pressure
Voltage
Range
R-404a
208-230/60/1
15
15
210 lbs.
194 lbs.
50°F-100°F
50°F-90°F
20-120 psi 198-253
WCF-1101W Water-Cooled
R-404a
208-230/60/1
15
15
210 lbs.
194 lbs.
50°F-100°F
50°F-90°F
20-120 psi 198-253
WCF-1001R* AC Remote
R-404a
208-230/60/1
15
15
210 lbs.
194 lbs.
50°F-100°F
50°F-90°F
20-120 psi 198-253
F
L
A
K
E
R
S
*Use Remote Condenser WC1.
WCF1101/B1048SS
30"
Series 2000
28"
DIMENSIONS/CAPACITY
76"
PLUMBING
Model
Number
Nominal
Capacity
Dimensions
Cabinet
Finish
WCF-2201A
2506 lbs.
30"w x 24"d x 28"h
SS
WCF-2201W
2506 lbs.
30"w x 24"d x 28"h
SS
WCF-2201R
2506 lbs.
30"w x 24"d x 28"h
SS
Water
Inlets/Outlets
1
⁄4 " male flare
⁄4 " MF / 3⁄8" FPT
1
⁄4 " male flare
1
Electrical Service
Opening
Drainhose
3
7
3
⁄8" I.D. x 9⁄16 " O.D.
⁄8" I.D. x 9⁄16 " O.D.
3
⁄8" I.D. x 9⁄16 " O.D.
7
⁄8 " diameter hole
⁄8 " diameter hole
7
⁄8 " diameter hole
PRODUCTION CHART
AIR-TEMPERATURE
WATER-TEMPERATURE
50ºF
70ºF
80ºF
50ºF
2506 lbs.
2244 lbs.
2112 lbs.
70ºF
2280 lbs.
2036 lbs.
1916 lbs.
90ºF
1901 lbs.
1711 lbs.
1628 lbs.
SPECIFICATIONS
32
"
48"
WCF2201/B1048SS
Model
Number
Condenser
WCF-2201A
Air-Cooled
OPERATING LIMITS
Refrigerant
Type
Standard
Electrical
Circuit Maximum Shipping Operating
Ambient
Water
Water
Capacity Fuse Size Weight
Weight Temperature Temperature Pressure
R-404a
208-230/60/1
15
15
342 lbs.
317 lbs.
50°F-100°F
50°F-90°F
20-120 psi 198-253
WCF-2201W Water-Cooled
R-404a
208-230/60/1
15
15
342 lbs.
317 lbs.
50°F-100°F
50°F-90°F
20-120 psi 198-253
WCF-2201R* AC Remote
R-404a
208-230/60/1
15
15
342 lbs.
317 lbs.
50°F-100°F
50°F-90°F
20-120 psi 198-253
*Use Remote Condenser CR1200.
DP-230
59 3⁄8 "
Voltage
Range
Model
Nominal
Storage Capacity
Dimensions
Cabinet Finish
Shipping
Weight
Operating
Weight
Standard
Electrical
Method of
Dispensing
Push Button
DPP-230
200 lbs.
30"w x 30"d x 593⁄8" h All Polyethylene
200 lbs.
170 lbs.
115/60/1
161467000
200 lbs.
30"w x 30"d x 593⁄8" h All Polyethylene
202 lbs.
172 lbs.
115/60/1
Coin/Token
161467001
200 lbs.
30"w x 30"d x 593⁄8" h All Polyethylene
200 lbs.
170 lbs.
115/60/1
161467002
200 lbs.
30"w x 30"d x 593⁄8" h All Polyethylene
200 lbs.
170 lbs.
115/60/1
Key Operated
Card Key
D
I
S
P
E
N
S
E
R
S
Bin Drain: 1" vinyl tube
Drain Connection: 1⁄2" FPT
Use with any 22" or 30" “I” Series cube icemaker.
"
30
30 "
DPP-230
13
D
I
S
P
E
N
S
E
R
S
D-45
28"
Model
Number
D-45
Model Dimensions
Nominal
Storage Capacity
Cabinet Finish
Cup
Clearance
Shipping
Weight
Operating
Weight
Standard
Electrical
16"w x 22"d x 28"h
45 lbs.
SS cabinet, ABS liner
7"
67 lbs.
53 lbs.
115/60/1
Drain Connection: 3⁄4" FPT
22"
16"
D-45
ED-150/200/250/300
Model
Number
Model Dimensions
5
Cabinet Finish
Cup
Clearance
Shipping
Weight
Operating
Weight
Standard
Electrical
ED-150
22"w x 30"d x 35 ⁄8"h
150 lbs.
SS cabinet, ABS liner
10"
151 lbs.
135 lbs.
115/60/1
ED-200
30"w x 30"d x 355⁄8"h
200 lbs.
SS cabinet, ABS liner
10"
197 lbs.
177 lbs.
115/60/1
ED-250
30"w x 30"d x 395⁄8"h
250 lbs.
SS cabinet, ABS liner
10"
201 lbs.
180 lbs.
115/60/1
ED-300
445⁄8"w x 30"d x 3615⁄16"h
300 lbs.
SS cabinet, ABS liner
10"
251 lbs.
226 lbs.
115/60/1
5
35 ⁄8"
Nominal
Storage Capacity
Drain Connection: 3⁄4" FPT
Use with Cornelius 330, 530, 630, 830, 1030 and 1230 “I” Series cube icemakers.
COMPATIBLE ICEMAKER "I" SERIES
Model
Number
322
522
D100
x
x
ED150
x
x
330
530
x
x
630
830
x
x
1030
1230
x
x
D45
A
C
C
E
S
S
O
R
I
E
S
14
ED200
ED250
30
"
x
ED300
30 "
x
ED-200
Cornelius Bagger
Remote Condensers
• Time-saving
• No mess
• Less melting
• Convenient
• Innovative design
Dimensions: 22"w x 101⁄4"d x 281⁄2"h
Shipping weight: 15 lbs.
• Weatherproof housing
• High-efficiency copper and
aluminum condenser
• Reduces air conditioning
requirements
Cabinet Finish: Galvanized
Model
Number
Refrigerant
Standard
Electrical
Shipping
Weight
CR-500
R-404-A
115/60/1
72 lbs.
Operating
Weight
Dimensions
Model
Number
Description
68 lbs.
18 ⁄4"w x 14"d x 34 ⁄4"h
B28
Bagger w/sealing tape dispenser
1
1
CR-800
R-404-A
208-230/60/1
100 lbs.
90 lbs.
281⁄2"w x 14"d x 401⁄8"h
BG8
1000 Count 81 lb. ice bags
CR-1200
R-404-A
208-230/60/1
115 lbs.
105 lbs.
281⁄2"w x 14"d x 401⁄8"h
TR2
Sealing tape (single roll)
CR-1400
R-404-A
208-230/60/1
130 lbs.
115 lbs.
281⁄2"w x 14"d x 401⁄8"h
CR-2400
R-404-A
208-230/60/1
124 lbs.
114 lbs.
281⁄2"w x 15"d x 373⁄4"h
WC-1
R-404-A
208-230/60/1
62 lbs.
57 lbs.
211⁄4"w x 121⁄4"d x 161⁄2"h
WCU
R-404-A
115/60/1
128 lbs.
118 lbs.
181⁄4"w x 251⁄4"d x 161⁄2"h
All Cornelius products meet appropriate agency approval, as listed below.
B122AP
B230AP
B322AP
B
I
N
S
B430AP
B530AP
B842SS
B1048SS
• Wide Selection…
Twelve models ranging from
120 to 1315 lbs. storage
capacity.
• Corrosion Proof…
All Cornelius storage bins
constructed of rotomolded
polyethylene or 304 grade
stainless steel are virtually
corrosion proof. Our standard
baked enamel finished bins
will provide years of
corrosion resistant service.
Bin Model
B122
Dimensions
WCF700
B1315SBB
• Easy Maintenance Bin
Liners…All rotomolded
polyethylene bin liners will
not crack, chip, dent or rust.
Our seamless design with
large radius corners allows
for easy cleaning and
enhances ice removal.
• Extra Wide Doors…
All Cornelius storage bins
are equipped with fullwidth urethane foam
insulated stainless steel
doors with chemical
resistant gasketing.
• Warranty…All Cornelius
storage bins are covered by
our comprehensive product
warranty. Contact your local
Cornelius agent for warranty
details.
• CFC Free Insulation…
All Cornelius bins are
constructed with an average
11⁄2" of rigid CFC free foam
insulation, providing superior
insulation efficiency.
Nominal
*Certified
Storage Capacity Storage Capacity
W
D
H
22"
29"
231⁄2" *
120 lbs.
90 lbs.
1
Cuber Series
322
330
522
530
630
Chunklet/Flaker Series
830 1030 1230 1444 1844 2448
1000 2000
46 lbs.
30"
29"
23 ⁄2"*
200 lbs.
120 lbs.
1
B322
22"
313⁄4"
48"*
300 lbs.
260 lbs.
x
B430
30"
325⁄16"
38"*
400 lbs.
290 lbs.
1
x
1
x
B530
30"
325⁄16"
48"*
500 lbs.
400 lbs.
1
x
1
x
x
1
54 lbs.
x
1
1
x
1
1
92 lbs.
x
1
1
108 lbs.
B842
42"
32"
48"*
800 lbs.
580 lbs.
1
1
1
1
B1048
48"
32"
48"*
1000 lbs.
670 lbs.
1
1
1
1
1
1
x
1315-SBB
48"
34"
68"*
1315 lbs.
1160 lbs.
x
x
x
x
x
FR-300SS
261⁄2"
42"
381⁄4"**
300 lbs.
260 lbs.
1 – Top adapter required
700
x
B230
Rated in accordance with ARI standard 820-88.
500
Shipping Weight.
* – Height dimensions include 6" adjustable legs
90 lbs.
1
1
1
1
1
1
1
182 lbs.
160 lbs.
x
x
360 lbs.
x
x
x
285 lbs.
* * – Bin supplied with 5" casters
15
S
P
E
C
I
F
I
C
A
T
I
O
N
G
U
I
D
E
MECHANICAL REQUIREMENTS FOR INSTALLATION OF
CORNELIUS ICE MACHINES AND STORAGE BINS
LOCATION
Always locate the ice machine where ambient temperatures will not fall below 50˚F nor rise above 100˚F.
CLEARANCE
Always make certain the machine and storage bin will fit through all doors and hallways leading to the final installation site.
When installed, there must be a 6-inch air clearance on rear, top and right side of Cornelius modular icemakers. Air intake and
discharge areas require a 6-inch clearance on all machines. Keep in mind when selecting the icemaker location that modular
machines may be stacked to increase production capacity as requirements grow.
UTILITY CONNECTIONS
Electrical, water and drain connections must be within 6 feet of machine location. All connections must meet national,
state and local codes.
ELECTRICAL REQUIREMENTS
Separate circuits, fuses and/or breakers are required for each icemaker or dispenser. Wire, fuse and circuit breaker sizes must be
calculated by a qualified electrician, based on the model’s specifications and must meet all national, state and local codes.
PLUMBING REQUIREMENTS
Ice machines must always be connected to the building’s cold water supply. For proper operation, water temperatures must not
exceed 45˚F-90˚F and pressure must be within 20-120 psi. Icemaker drain tubing must be a minimum of 1/2" I.D. Bin drain tubing must be
a minimum of 3/4" I.D. Icemaker and bin drains must be vented. Separate drain lines must be used for the icemaker and bin. Water-cooled
condenser drains must not be vented nor connected to icemaker or bin drain lines. All plumbing must meet national, state and local codes.
QUICK REFERENCE SIZING GUIDE BY CUSTOMER VOLUME
Customers
Application
Sizing Guide (daily ice use)
100
Restaurant
Cocktail Bar
Water Glass
Salad Bar
Beverage Only
Beverage Only
Beverage Only
Guest Ice
Hotel Catering
Patient Ice
Cafeteria
1.5 lbs. ice per meal sold
3.0 lbs. ice per seat
6 oz. ice per 12 oz. glass
35 lbs. of ice per cubic foot
5 oz. ice per 7-10 oz. cup
8 oz. ice per 12-16 oz. cup
12 oz. ice per 18-24 oz. cup
5 lbs. per hotel room
1 lb. per person
10 lbs. per patient
1 lb. per person served
180
360
45
—
38
60
90
600
120
1,200
120
250
500
1,000
(figures below include a 20% safety factor)
450
900
113
—
94
150
225
1,500
300
3,000
300
900
1,800
225
—
188
300
450
3,000
600
6,000
600
1,800
3,600
450
—
375
600
900
6,000
1,200
12,000
1,200
1,500
2,700
5,400
675
—
563
900
1,350
9,000
1,800
18,000
1,800
QUICK SIZING GUIDELINES
To determine the ice usage in a bar or restaurant, count the number of chairs for customers, multiply that number by 3 lbs. of ice
per bar stool and 1.5 lbs. per table seat. This should fulfill the customer’s needs, unless they are offering self-serve beverages or there is
an exceptionally large carry-out business. If the carry-out customer is at least one-third of the in-store business, add 1 lb. of ice for
each carry-out customer. Nursing home and hospital ice needs are calculated in much the same way. It is only necessary to count the
number of beds and refer to the following amounts: Hospitals need 10 lbs. of ice per bed; nursing homes require 6 lbs. of ice per bed.
Be sure to take into consideration other uses such as cafeterias and staff dining rooms, provided these areas do not have their own
icemakers. For churches or other places that use ice only once or twice a week, a small production machine on a large bin may be
adequate and economical to fulfill an occasional need for ice. However, if this is done and two meetings are scheduled one after the
other, the machine may not have time to adequately refill the bin before the start of the second engagement. When calculating total
daily ice usage make certain to include all anticipated ice usage. The final step is to consult the Cornelius specification sheets for the
model selected to determine its production capabilities under the operating conditions at the customer’s place of business.
16
CALCULATION METHOD FOR SIZING ICE MACHINES AND STORAGE BINS
The quick reference sizing guide works well in many cases; however, more and more customers’ ice needs are changing. Today’s
customers use ice for numerous applications such as product cooling, self-serve beverages, product packaging, display and, in
some cases, retail package sales. To meet customer needs, a more detailed calculation of ice usage and storage requirements is
required. Listed below are the formulas and guidelines for use in these calculations.
SIZING ICE MACHINES
SELF-SERVE BEVERAGES OR CARRY-OUT – You need to know the size and quantity of drinks sold. Refer to the following table.
This table assumes the cups are completely filled with ice.
Cup Size (fl. oz.)
Average Beverage (fl. oz.)
6
3
Average Ice (oz.)
3
12
6
6
16
8
8
20
10
10
32
16
16
48
24
24
After establishing the number of different sized cups sold in a busy day and multiplying that number by the quantities
indicated, a fairly accurate estimate can be determined. If the establishment uses an ice-cooled beverage dispenser, iced salad
bar or some other type of display that requires ice, the amounts needed are examined separately under the Product
Display/Packing and Coldplate Cooling sections.
COLDPLATE COOLING – To calculate the amount of ice consumed cooling the coldplate, choose the appropriate operating condition and multiply by the “average amount of beverage” in the “average cup size.”
EXAMPLE:
Soda/Syrup Inlet Temperature
Drinks
per min. 50
2
4
6
8
10
12
14
0.6
1.1
1.7
2.3
2.6
3.4
3.9
60
70
80
90
100
1.1
2.3
3.4
4.5
5.6
6.8
7.9
1.7
3.4
5.1
6.8
8.5
10.2
11.8
2.3
4.5
6.8
9.0
11.3
13.5
15.8
2.8
5.6
8.5
11.3
14.1
16.9
19.7
3.4
6.8
10.2
13.5
16.9
20.3
23.7
Find the amount of ice “burned” on a coldplate for a system that has the following
operating conditions:
1.
80˚F inlet soda/syrup temperature
2.
6 vends/minute
3.
18 fl. oz. average amount of beverage drink
Therefore:
S
P
E
C
I
F
I
C
A
T
I
O
N
From the table choose row “6” and column “80.”
This gives a constant of 6.8.
6.8 x 18 = 122.4 lbs./hour
PRODUCT DISPLAY/PACKING – To size an icemaker to handle product display or packing, it is necessary to determine the
cubic feet of ice needed in 24 hours (length x width x depth). Since the calculations are done using the foot as the standard unit
of measure, the depth must be converted into feet. If the depth is less than 12 inches, divide depth required by 12 to make the
conversion to feet. A cubic foot of ice weighs approximately 35 lbs., so multiply the cubic feet of space to be used for product
display or packing by 35 to determine the ice needs for a 24-hour period.
EXAMPLE:
A supermarket has a fish display case that is 25 feet long and 3 feet deep.
They wish to set the fish in ice to a depth of 6 inches (6 inches = .50 foot).
Ice requirement for 24 hours: 25 ft. x 3 ft. x .5 ft. = 37.5 cu.ft.
37.5 cu. ft. x 35 lbs. = 1,312.5 lbs.
G
U
I
D
E
SAMPLE:
A restaurant has 200 table seats with 4 turns per night, 20 stools at the bar and a salad bar that measures 6 ft. x 3 ft. with a required
ice depth of 4 inches.
General ice usage:
20 (bar stools) x 3 lbs. = 60 lbs.
200 (seats) x 4 (turns) x 1.5 lbs. = 1,200 lbs.
Product display:
6 ft. x 3 ft. x .33 ft. = 5.94 cu. ft.
5.94 cu. ft. x 35 lbs. = 207.9 lbs.
Finally, add all ice usage to determine the requirement for a 24-hour period:
1,200 lbs. + 60 lbs. + 207.9 lbs. = 1,467.9 lbs. ice per day
17
S
P
E
C
I
F
I
C
A
T
I
O
N
The previous sizing methods assume that the icemaker will run continuously 24 hours a day. This total utilization of the icemaker
gives the customer the most cost effective way of producing the required ice. It also requires the bin to be properly sized or the customer will run out of ice.
The example below shows how two operations can have very different usage patterns, yet still require the same size icemaker.
Convenience Store
Restaurant
Monday
400 lbs.
Closed
Tuesday
400 lbs.
200 lbs.
Wednesday
400 lbs.
200 lbs.
Thursday
400 lbs.
200 lbs.
Friday
400 lbs.
700 lbs.
Saturday
400 lbs.
800 lbs.
Sunday
400 lbs.
700 lbs.
2,800 lbs.
2,800 lbs.
Weekly Total
Using our formula - 2,800 lbs. wkly. usage ÷ 7 days x 1.2 (“safety factor”) = 480 lbs. ice/day
SIZING STORAGE BINS
When ice is used in equal amounts 7 days per week, as in our convenience store example, the storage bin can be sized to
match the production capacity of the icemaker. Each day approximately 500 lbs. will be produced and 500 lbs. will be used.
Some people think that to size the bin they need only match the bin to the highest day’s usage. This will not always work
and often results in a customer running out of ice. If we had used this method for the restaurant example above, we would
have specified an 800 lb. bin. On Friday, the restaurant would have used 700 lbs. of ice, leaving 100 lbs. in the bin. With
Saturday’s production of 500 lbs. we would have only 600 lbs. in the bin — and we would need 800 lbs. — leaving us 200 lbs.
short on Saturday and again on Sunday. The result would be an unhappy customer.
This is the case in our restaurant example. There are three days — Friday, Saturday and Sunday — when the required amount
of ice exceeds the production capacity of the icemaker (these are called “peaks”). In this case, the bin and not the icemaker should
be sized to take care of these “peak” days.
The best way to determine the size bin required is to work backwards from the last “peak” day — in this case Sunday. Take the
amount by which each day’s usage exceeds the 500 lb. daily production of the icemaker.
G
U
I
D
E
Sunday usage
- 700 lbs. = 200 lbs. over production
Saturday usage
- 800 lbs. = 300 lbs. over production
Friday usage
- 700 lbs. = 200 lbs. over production
Total = 700 lbs. over production
Add the total (700 lbs.) to the daily production figure (500 lbs.) to get the bin capacity required to meet the restaurant’s
weekend demand for ice. This method tells us we need at least a 1,200 lb. bin.
Once you think you know the size of the bin required, you can check your estimate as follows:
Assuming the bin is empty Sunday evening, 500 lbs. will be produced on Monday with no usage, and another 500 lbs. on Tuesday
for a total of 1,000 lbs. in the bin. Tuesday’s usage of 200 lbs. will lower the bin contents to 800 lbs. but with 500 lbs. of production,
the bin will be full at 1,200 lbs. on Wednesday. The same will be true for Thursday. As we enter the weekend peak period on Friday
we have 1,200 lbs. in the bin from which we will use 700 lbs. This leaves 500 lbs. in the bin, plus 500 lbs. produced in 24 hours for a
total of 1,000 lbs. Saturday’s usage of 800 lbs. reduces the ice available to 200 lbs., plus 500 lbs. of production for a total of 700 lbs. exactly the amount needed for Sunday’s usage.
It’s always a good idea to add the same 20% “safety factor” to the bin as we did to the icemaker. This adjusts for the ice voids
and pyramiding that can occur in the bin. In the case of our restaurant, the addition of the “safety factor” means we would look for
a bin with a storage capacity of approximately 1,400 lbs. (1,200 x 1.2 = 1,440). We can see that an icemaker rated at 500 lbs. of daily
product would easily meet the needs of both of the previous examples, provided that the icemaker runs continuously.
18
A GENERAL REVIEW OF THE RULES FOR SIZING ICEMAKERS AND BINS
1.
Ice needs are seldom uniform; more ice is generally needed in summer than in winter. Understanding the ice usage of the
customer is a must to assure sufficient ice is available to meet peak demands. Remember, water temperature, as well as the
surrounding air temperature, affects the output capacity of icemakers. Determine what these factors will be during the
peak demand periods. Then verify the icemaker and storage bin selection by the preceding method and refer to the
machine’s production chart to determine the expected capacity under these conditions.
2.
Determine the size of the icemaker required by dividing the “worst case” week’s total ice usage by seven. Then add in a 20%
“safety factor.”
3.
If equal amounts of ice are used each day (including weekends), size the bin to match the ice production.
4.
If there are peaks (where a day’s usage exceeds a day’s production), size the bin to store adequate ice to meet the peak
demand(s).
5.
Remember that the per pound cost of making ice is about four times the per pound cost of storing ice.
It’s always much less expensive for the customer to meet their “peak” demands by using the storage bin when possible.
6.
When sizing the bin, double-check the bin’s true capacity, using the current ARI directory.
7.
A final element to take into account is the shape of the bin, the location of the icemaker(s) on the bin, and the size and
location of the icemaker(s’) ice discharge. An ice discharge opening centered on an extremely wide bin will result in much
more pyramiding and, therefore, less storage.
CUBE ICE MACHINES
Model __________ manufactured by IMI Cornelius, rated in accordance with and certified to comply to ARI Standard 810-91,
having a 24-hour production capacity of _________ lbs. at 90˚F air and 70˚F water temperatures. Cubers to be certified to NSF
Standard 12 and display symbol of certifying agency. Ice machines will include, as standard equipment, the following:
•
304-grade stainless steel frame assembly and exterior panels.
•
Built-in water strainer and pressure regulating flow control.
•
Self-diagnosing solid state microprocessor control system, with programmable flush cycle.
•
Thermistor-type sensors for uniform ice-thickness control and condenser fan control.
•
Environmentally safe R-404a refrigerant.
•
Split-compartment design, isolating critical components of wet environment.
•
Non-corrosive ABS evaporator compartment.
•
Epoxy encapsulated proximity switch for harvest termination and full bin control.
S
P
E
C
I
F
I
C
A
T
I
O
N
ICE STORAGE BIN
Model ________ manufactured by IMI Cornelius, rated in accordance with and certified to comply with ARI Standard 820-88, to
have a storage capacity of _______ lbs. Exterior finish of __________, with interior liner of one-piece seamless roto-molded
polyethylene. Ice machine with storage bin will measure ______" wide, _______" deep and ______" high including 6" adjustable
legs. Storage bin to be certified to NSF Standard 12 and display symbol of certifying agency.
HOSPITALITY DISPENSER
Model ___________ dispenser manufactured by IMI Cornelius, for use with series ____________ cube ice machine. Dispenser to
be rated in accordance with and certified to comply with ARI Standard 820-88, having a storage capacity of _____ lbs. Dispenser will
be equipped to be actuated by __________ (push button, key, room card, coin/token) control. Storage bin to be classified to NSF
Standard 12 and display symbol of certifying agency. The dispenser will include, as standard equipment, the following:
•
Solid state adjustable portion control.
•
Adjustable automatic off-cycle agitation.
•
Interior and exterior roto-molded polyethylene construction.
•
6 -inch adjustable legs.
G
U
I
D
E
FLAKE ICE MACHINES
Model ___________ manufactured by IMI Cornelius, having a 24-hour production capacity of ________lbs. at 90˚F air and 70˚F
water temperatures. Flakers to be certified to NSF Standard 12 and display symbol of certifying agency. Flakers will include, as
standard equipment, the following:
•
300 series stainless steel evaporator.
•
Top-mounted auger drive mechanism.
•
Manual reset auger motor overload control.
19