PSA7000 Hardware Guide

PSA7000 Hardware Guide
Pu
ublish
hed Da
at e
March 2017
Document Revision
1.0
Copyright © 2014-2017, Pulse Secure, LLC. All rights reserved. All trademarks are the property of their
respective owners. All specifications are subject to change without notice.
Pulse Secure, LLC assumes no responsibility for any inaccuracies in this document. Pulse Secure, LLC reserves
the right to change, modify, transfer, or otherwise revise this publication without notice.
Contacting Pulse Secure:
Pulse Secure, LLC
2700 Zanker Road, Suite 200
San Jose, California 95134
www.pulsesecure.net
© 2017 Pulse Secure, LLC. All rights reserved
2
PSA7000 Hardware Guide
Contents
System Overview
Introduction ............................................................................................................................................................... 5
LED Control Panel .................................................................................................................................................... 6
Management Port LEDs .......................................................................................................................................... 8
INT and EXT Port LEDs ............................................................................................................................................ 8
Beeping and Alarms ................................................................................................................................................ 9
SATA Drives .............................................................................................................................................................. 10
LCD Display .............................................................................................................................................................. 10
LCD Modes .................................................................................................................................................... 11
Display Mode ................................................................................................................................................ 12
Menu Mode ................................................................................................................................................... 14
Hardware Specifications
System Measurements ......................................................................................................................................... 15
Power Rating............................................................................................................................................................ 15
Environmental Requirements.............................................................................................................................. 16
Component Specifications ................................................................................................................................... 16
Mounting Rails......................................................................................................................................................... 16
Where to Get Replacement Components ....................................................................................................... 16
Console and Initial Configuration
Connect Console and Network ........................................................................................................................... 17
Power On the System ........................................................................................................................................... 18
Configure Basic Settings ....................................................................................................................................... 18
Change the Personality ......................................................................................................................................... 20
Access the Web Admin Interface ....................................................................................................................... 21
Licensing the System ............................................................................................................................................. 22
Installation and Management
Unpacking the System .......................................................................................................................................... 23
Rack Mounting ........................................................................................................................................................ 23
Choosing a Setup Location ....................................................................................................................... 23
Rack Mounting Instructions ...................................................................................................................... 24
Installation Procedure ................................................................................................................................ 25
Installing and Removing Hard Drives ................................................................................................................ 28
Replacing Power Supplies .................................................................................................................................... 29
Network Cables ....................................................................................................................................................... 30
© 2017 Pulse Secure, LLC. All rights reserved
3
PSA7000 Hardware Guide
PSA7000f ........................................................................................................................................................ 30
PSA7000c ....................................................................................................................................................... 31
Serial Number Placement .................................................................................................................................... 31
Standard Warnings and Compliance
About Standard Warnings .................................................................................................................................... 32
Safety Certifications ............................................................................................................................................... 32
Electrical Safety ....................................................................................................................................................... 32
General Safety ......................................................................................................................................................... 33
Installation Instructions......................................................................................................................................... 37
Circuit Breaker ........................................................................................................................................................ 38
Power Disconnection Warning ............................................................................................................................ 39
Equipment Installation .......................................................................................................................................... 41
Restricted Area........................................................................................................................................................ 42
Redundant Power Supplies ................................................................................................................................. 44
Backplane Voltage .................................................................................................................................................. 45
Comply with Local and National Electrical Codes .......................................................................................... 46
Product Disposal .................................................................................................................................................... 47
Hot Swap Fan Warning ......................................................................................................................................... 48
Power Cable and AC Adapter.............................................................................................................................. 50
Certification Statements ....................................................................................................................................... 52
Japan ............................................................................................................................................................... 52
Israel ................................................................................................................................................................ 52
Saudi Arabia .................................................................................................................................................. 52
South Korea .................................................................................................................................................. 52
Taiwan ............................................................................................................................................................. 52
Thailand .......................................................................................................................................................... 53
© 2017 Pulse Secure, LLC. All rights reserved
4
PSA7000 Hardware Guide
System Overview
Introduction
The PSA7000 offers a 17.7" short-depth 2U foot-print with advanced air flow thermal control and two rear
hot-swappable drivebays. Below is the front and rear view of the system. The disk drives (HDD1 and HDD2)
and power supplies (PWR1 and PWR2) are accessible from the rear. For added system security, the USB port
has been disabled.
Front panel view:
Power switch
Console
LCD display
Remote
management
Internal ports
(INT)
External ports
(EXT)
Rear panel view:
HDD1
HDD2
PWR1
PWR2
© 2017 Pulse Secure, LLC. All rights reserved
5
PSA7000 Hardware Guide
LED Control Panel
There are two buttons located on the front of the chassis: a reset button and a power on/off button. The
reset button is used to reboot the system. The main power switch activates or deactivates power to the
server system.
The control panel includes a power on/off button and a reset button.
Power: The main power switch is used to apply or remove power from the power supply to the server system. Turning off system power with this button removes the main power but keeps standby power supplied
to the system. Therefore, you must unplug system before servicing.
Reset: The reset button is used to reboot the system.
The control panel displays six LEDs to monitor the system.
Information LED: Alerts operator of several states, as noted in the table below:
Status
Description
Continuously on and red
An overheat condition has occurred. This may be caused by cable
congestion.
Blinking red (1Hz)
Fan failure; check for an inoperative fan.
Blinking red (0.25Hz)
Power failure; check for a non-operational power supply.
© 2017 Pulse Secure, LLC. All rights reserved
6
PSA7000 Hardware Guide
NIC1 (GLAN1): Associated with the Management port. It indicates network activity when flashing.
NIC2 (GLAN2): Unused. Will always be off.
HDD: Indicates IDE channel activity or SATA drive activity when flashing.
Power: Indicates power is being supplied to the system power supply. This LED should be illuminated when
the system is operating.
Power Failure: When this LED flashes, it indicates a power failure in the power supply.
© 2017 Pulse Secure, LLC. All rights reserved
7
PSA7000 Hardware Guide
Management Port LEDs
The management port has two LEDs:
The yellow LED indicates activity, while the link LED may be green, amber, or off to indicate the speed of the
connection.
LED
Color
Description
Activity
Yellow (flashing)
Active
Link
Off
No connection
Amber
1 Gbps speed
Green
100 Mbps speed
INT and EXT Port LEDs
The PSA7000C has 4 INT/EXT copper LAN ports located on the front. Each Ethernet port has two LEDs:
LED
Color
Description
Activity
Green (flashing)
LAN active
Link
Off
100 Mbps link speed or no connection
Amber
1 Gbps link speed
Green
10 Gbps link speed
© 2017 Pulse Secure, LLC. All rights reserved
8
PSA7000 Hardware Guide
The PSA7000F has 4 INT/EXT fiber ports located on the front:
Each SFP+ connector has two LEDs. The LED on the left indicates the activity status of the connector.
The LED on the right indicates link speed:
LED
Color
Description
Activity
Blinking green
Activity
Link
Yellow
1 Gbps link speed
Green
10 Gbps link speed
Beeping and Alarms
Beep Code
Description
5 short beeps + 1 long beep every
5 seconds
No memory detected in the system
Continuous beep (“i” LED on
front panel turns RED)
System overheat condition
Continuous beep (Power failure
LED comes on, Front panel)
a) Both power supply modules connected but one power cord
connected
b) One of the 2 power supplies has failed
© 2017 Pulse Secure, LLC. All rights reserved
9
PSA7000 Hardware Guide
SATA Drives
The system uses hot swappable SATA drives.
There are two drives:
•
HDD1
•
HDD2
Each drive has two LEDs.
Green: When illuminated, this green LED (on the SATA drive carrier) indicates drive activity.
Red: The red LED indicates a SATA drive failure. If one of the SATA drives fail, you should be notified by your
system management software.
Note: The unit will only support two HDDs. The unit will not recognize the third drive if installed.
LCD Display
The LCD supports a Display mode (default) and Menu mode. The Display mode describes the current
state of the system, such as normal state or error conditions (e.g., fan speed and overheat).
Use the directional buttons to access the Menu mode and find device information.
© 2017 Pulse Secure, LLC. All rights reserved
10
PSA7000 Hardware Guide
LCD Modes
The LCD has two modes:
•
Display mode—The default. The LCD goes into Display mode after boot-up is complete.
•
Menu mode—It is activated when the user presses either the Enter button or any of the arrow
buttons. A single press of those buttons will change to Menu mode and load the default menu selection
(see Menu mode designs).
If the user presses the Cancel button, the LCD immediately changes back to D isplay mode and shows the
appropriate state. If the LCD is already in Display mode and the user presses Cancel, then nothing happens.
The LCD remains in Display mode. If the LCD is in Menu mode and the user does not press any button for
more than two minutes, then the LCD changes back to Display mode.
© 2017 Pulse Secure, LLC. All rights reserved
11
PSA7000 Hardware Guide
Display Mode
In the Display mode, LCD is either set to NORMAL or shows a label that describes an error condition.
If all systems are functioning normally, then the LCD shows NORMAL. The second line in the NORMAL state
is used to show whether the appliance is configured as part of a cluster.
The valid states are Clustering OFF and Clustering ON.
© 2017 Pulse Secure, LLC. All rights reserved
12
PSA7000 Hardware Guide
Error Conditions
If more than one error condition is detected, all error conditions will be displayed in sequence with a two
seconds’ pause before switching to the next one.
All error conditions are cleared prior to return to the NORMAL state. Error conditions include:
•
Overheat
•
Fan Failure
•
RAID Errors
© 2017 Pulse Secure, LLC. All rights reserved
13
PSA7000 Hardware Guide
Menu Mode
Pressing Enter or any Arrow key puts the LCD into Menu mode.
Pressing the Right and Left arrows keys cycles through the available system configuration data, starting with
Internal IP and going clockwise.
Pressing Cancel at any point exits to Display mode.
If Internal IP and External IP are not used, they will show Disabled instead of showing the IP address.
© 2017 Pulse Secure, LLC. All rights reserved
14
PSA7000 Hardware Guide
Hardware Specifications
This chapter describes the specifications and components for the PSA7000c (copper) and PSA7000f (fiber).
System Measurements
These figures are for an unpackaged system.
Category
PSA7000c and PSA7000f
Form factor
2U chassis
Width
17.2 inches (43.7 cm)
Height
3.5 inches (8.9 cm)
Depth
17.7 inches (45 cm)
Weight
30 lbs (13.6 kg)
Power Rating
The system supports redundant power supplies (dual FRU), and the maximum power rating is given in the table
below.
Category
PSA7000c and PSA7000f
Input voltage range
100 - 240V
Input current
10 Amps maximum
Input wattage
700W
Input frequency range
50 - 60Hz
In the unlikely event that your power supply fails, replacement is simple and can be done without tools.
The power supplies are redundant and hot-swappable.
© 2017 Pulse Secure, LLC. All rights reserved
15
PSA7000 Hardware Guide
Environmental Requirements
Category
PSA7000c and PSA7000f
Operating temperature
10°C to 35°C (50°F to 95°F)
Storage temperature
(-40°C) ~ 60°C (-40°F ~ 140°F)
Relative humidity (operating)
8% ~ 90% (non-condensing)
Relative humidity (storage)
5% - 95% (non-condensing)
Component Specifications
Category
PSA7000c and PSA7000f
CPU
Haswell E3-1275
Memory
32GB
Storage HDD
2 x 1TB SATA3, hot-swap
Security module
1x TPM 1.2
Network ports
• PSA7000c: 2 Dual-port 1G/10G Ethernet Intel X540 (4 x RJ45)
• PSA7000f: 2 Dual-port 1G/10G Ethernet Intel 82599ES (4 x SFP+)
External I/O ports
• 1x console RJ-45 port
• 1x10/100/1000 management port
Cooling
4x 4cm counter-rotating fans
The PSA7000f model offers SFP+ interfaces supporting both 10G fiber and 10G copper networks with a direct
attach transceiver cable.
Mounting Rails
The PSA7000 can be placed in a rack for secure storage and use. To set up your rack, follow the step-bystep instructions included in this manual.
Where to Get Replacement Components
Although not frequently, you may need replacement parts for your system. To ensure the highest level of
professional service and technical support, go to https://www.pulsesecure.net/support/.
© 2017 Pulse Secure, LLC. All rights reserved
16
PSA7000 Hardware Guide
Console and Initial Configuration
Connect Console and Network
1.
2.
Do not power on the system yet. First, get the RJ45 to DB9 serial console cable.
Note: A DB9 to USB adapter is not provided.
Connect the RJ45 end of the cable to the appliance port labeled CONSOLE and the DB9 end to a laptop.
Additionally, connect a network cable from the INT port on the appliance to a switch port:
To network
3.
On the laptop, configure a terminal emulation utility, such as HyperTerminal or PuTTY, to use these settings: 9600 speed, 8 data bits, 1 stop bit, no flow control.
To find your COM port in Windows, go to Start > Search > Device Manger > Ports (COM & LPT)
> USB Serial Port (COM#).
© 2017 Pulse Secure, LLC. All rights reserved
17
PSA7000 Hardware Guide
Power On the System
Do this:
1.
2.
3.
Connect the AC power cables from a power source to both of the power supplies. An alarm will sound
until both power supplies are connected.
The appliance will begin powering-on automatically when the first power cable is connected. Both power
cables must be connected for normal operations.
Observe the status LEDs (where applicable) on each power supply faceplate. If an AC power supply is
correctly installed and functioning normally, the AC OK and DC OK LEDs light steadily, and the PS FAIL
LED is not lit.
Note: After powering off a power supply, wait for at least 60 seconds before turning it back on. After
powering on a power supply, wait for at least 60 seconds before turning it off.
After a power supply is powered on, it can take up to 60 seconds for status indicators—such as the status
LEDs on the power supply and the show chassis command display—to indicate that the power supply is
functioning normally. Ignore error indicators that appear during the first 60 seconds.
Configure Basic Settings
When you boot an unconfigured PSA7000, you need to enter basic network and machine information through
the console to make it accessible to the network. Based on your selection of personality, a different binary
will boot up in the system. After entering these settings, you can continue configuring the PSA7000 through
the administrator Web console.
During this basic setup process, you define the “personality” of the PSA7000. For example, you can set up
the PSA7000 to act as a Pulse Connect Secure device, Pulse Policy Secure device, or Pulse One Service.
Note: If PSA7000 is set up as Pulse Connect Secure or Pulse Policy Secure device, it can be switched
to any other personality anytime.
But, setting up PSA7000 as Pulse One is irreversible; you cannot switch to Pulse Connect Secure or
Pulse Policy Secure builds later.
The installation process may take up to 20 minutes.
Do this to perform basic setup:
1.
Enter the number corresponding to the personality for which you want to configure the PSA7000.
© 2017 Pulse Secure, LLC. All rights reserved
18
PSA7000 Hardware Guide
2.
For example, if your screen looks like this:
Press 1 to install the Pulse Connect Secure package. Press 2 to install the Pulse Policy Secure package. Press 3 to
install the Pulse One Service.
3.
Enter y to proceed, and then enter y to accept the license terms (or enter r to read the license first).
4. Follow the directions in the console, and enter the machine information for which you are prompted,
including the following:
•
IP address of the internal port (you configure the external port through the administrator Web console
after initial configuration)
•
Network mask
•
Default gateway address
•
Primary DNS server address
•
Secondary DNS server address (optional)
•
Default DNS domain name (for example, acmegizmo.com)
•
WINS server name or address (optional)
•
Administrator username
•
Administrator password
•
Common machine name (for example, connect.acmegizmo.com)
•
Organization name (for example, Acme Gizmo, Inc.)
•
Enter random text (used for auth certificate)
After you perform the basic setup, you are ready to license the software, verify accessibility, and complete
the configuration process through the PSA7000 administrator Web console.
© 2017 Pulse Secure, LLC. All rights reserved
19
PSA7000 Hardware Guide
Change the Personality
Changing a personality deletes all configuration files and system and user data. You must perform the basic
setup again to reestablish network connectivity. The installation process may take up to 20 minutes.
Note: If PSA7000 is set up as Pulse Connect Secure or Pulse Policy Secure device, it can be switched
to any other personality anytime.
But, setting up PSA7000 as Pulse One is irreversible; you cannot switch to Pulse Connect Secure or
Pulse Policy Secure builds later.
Do this to change the personality:
1.
Start a console session.
2.
Select option 4, System Operations.
3.
Select option 5, Factory reset.
4.
Enter the number corresponding to the personality for which you want to configure the PSA7000.
For example, if your screen looks like this:
Press 1 to install the Pulse Connect Secure package. Press 2 to install the Pulse Policy Secure package. Press 3 to
install Pulse One Service.
5.
Follow the prompts to complete your configuration.
To change the personality from the administrator Web console:
1.
In the admin console, choose Maintenance > System > Change Personality.
2.
Click Browse to select the service package to install.
3.
Click Change Now.
© 2017 Pulse Secure, LLC. All rights reserved
20
PSA7000 Hardware Guide
Access the Web Admin Interface
1. Launch a web browser from a laptop that is network connected.
2. Point the browser at the same IP address that was assigned to the internal port followed by /admin (for
example, https://a.b.c.d/admin).
3. When prompted with the security alert to proceed without a signed certificate, click Yes. When the
administrator sign-in page appears, you have successfully connected your device to the network.
4. On the sign-in page, enter the administrator username and password you created earlier. Then click Sign In.
The administrator Web console opens to the Overview page.
© 2017 Pulse Secure, LLC. All rights reserved
21
PSA7000 Hardware Guide
Licensing the System
After you install the device and perform basic setup, you are ready to license it.
To license your device, follow instructions received in an email from Pulse Secure. For more information, see
https://www.pulsesecure.net/support.
The device uses the common machine and organization names to create a self-signed digital certificate for
use during product evaluation and initial setup.
We strongly recommend that you import a signed digital certificate from a trusted certificate authority (CA)
before you deploy the device for production use.
© 2017 Pulse Secure, LLC. All rights reserved
22
PSA7000 Hardware Guide
Installation and Management
Unpacking the System
You should inspect the box that the chassis was shipped in and note if it was damaged in any way. If the
chassis itself shows damage, you should file a damage claim with the carrier who delivered it.
Decide on a suitable location for the rack unit that will hold your chassis. It should be situated in a clean,
dust-free area that is well ventilated. Avoid areas where heat, electrical noise and electromagnetic fields are
generated. You will also need it placed near a grounded power outlet. Be sure to read the Rack and Server
Precautions in the next section.
Warning: If you unscrew and open the chassis cover, it will void your product warranty. There is a tamper
proof seal over the screws that looks like this:
Rack Mounting
The box your chassis was shipped in should include two sets of rail assemblies, two rail mounting brackets,
and the mounting screws you will need to install the system into the rack.
Choosing a Setup Location
•
Leave approximately 30 inches of clearance in the back of the rack to allow for sufficient airflow and ease
in servicing.
•
This product is for installation only in a Restricted Access Location (dedicated equipment rooms, service
closets and the like).
Rack Precautions
•
Ensure that the leveling jacks on the bottom of the rack are fully extended to the floor with the full weight
of the rack resting on them.
•
In single rack installation, stabilizers should be attached to the rack.
•
In multiple rack installations, the racks should be coupled together.
•
Always make sure the rack is stable before extending a component from the rack.
•
You should extend only one component at a time - extending two or more simultaneously may cause the
rack to become unstable.
© 2017 Pulse Secure, LLC. All rights reserved
23
PSA7000 Hardware Guide
General Server Precautions
•
Review the electrical and general safety precautions that came with the components you are adding to
your chassis.
•
Determine the placement of each component in the rack before you install the rails.
•
Install the heaviest server components on the bottom of the rack first, and then work up.
•
Use a regulating uninterruptible power supply (UPS) to protect the server from power surges, voltage
spikes and to keep your system operating in case of a power failure.
•
Allow the hot plug hard drives and power supply modules to cool before touching them.
•
Always keep the rack's front door and all panels and components on the servers closed when not servicing
to maintain proper cooling.
Rack Mounting Instructions
•
Ambient Operating Temperature — If installed in a closed or multi-unit rack assembly, the ambient
operating temperature of the rack environment may be greater than the ambient temperature of the room.
Therefore, consideration should be given to installing the equipment in an environment compatible with
the manufacturer’s maximum rated ambient temperature (Tmra).
•
Reduced Airflow — Equipment should be mounted into a rack so that the amount of airflow required for
safe operation is not compromised.
•
Mechanical Loading — Equipment should be mounted into a rack so that a hazardous condition does
not arise due to uneven mechanical loading.
•
Circuit Overloading — Consideration should be given to the connection of the equipment to the power
supply circuitry and the effect that any possible overloading of circuits might have on overcurrent protection
and power supply wiring. Appropriate consideration of equipment nameplate ratings should be used when
addressing this concern.
•
Reliable Ground — A reliable ground must be maintained always. To ensure this, the rack itself should be
grounded. Attention should be given to power supply connections other than the direct connections
to the branch circuit (i.e. the use of power strips, etc.).
© 2017 Pulse Secure, LLC. All rights reserved
24
PSA7000 Hardware Guide
Installation Procedure
Take the following steps to rack mount the PSA7000.
Step 1 - Identify the Parts
There is a left and right rail assembly for the PSA7000, as marked by the (L) and (R) stickers on the inner rails:
Each assembly has 3 parts: inner rail, middle rail, and outer rail.
Step 2 - Separate the Rails
Pull the inner rails out of the middle rails:
To release an inner rail, press the locking tab down.
© 2017 Pulse Secure, LLC. All rights reserved
25
PSA7000 Hardware Guide
Step 3 - Attach the Inner Rails
Attach the inner rails to the sides of the PSA7000:
The tabs on the side of the chassis slide into the rails.
Press down hard on the area shown in the picture, then slide the inner rail forward, pushing firmly until it
clicks into the locked position.
Step 4 - Attach to the Rack
Put the outer and middle rails on the rack. Hang the rail hooks on the rack holes:
If your rack has round holes, use the adaptors provided:
© 2017 Pulse Secure, LLC. All rights reserved
26
PSA7000 Hardware Guide
Step 5 - Mount the Chassis
Extend the middle rails. Then, lift the PSA7000 and slide the ends of the outer rails into the middle rails:
As you’re sliding it, press the locking tabs down on both sides of the chassis. The rails will lock into place:
Note: You may require two people to safely mount the chassis.
Step 6 - Bolt the Chassis
Next, bolt the front of the chassis to the rack with the screws provided:
Congratulations!
You have completed racking your PSA7000.Installing and Removing Hard Drives
© 2017 Pulse Secure, LLC. All rights reserved
27
PSA7000 Hardware Guide
Installing and Removing Hard Drives
The drives (HDD1, HDD2) are labeled on the back of the system.
Removing the Hard Drive Trays from the Chassis
2
1
1.
Press the Release button on the drive tray. This extends the drive tray handle.
2.
Use the handle to pull the drive out of the chassis.
The drives are mounted in drive carriers to simplify their installation and removal from the chassis. These
carriers also help promote proper airflow for the drive bays.
Warning: Except for short periods of time (swapping hard drives), do not operate the server with the hard
drives empty. The hard drive tray must have a hard drive or dummy drive installed.
Installing a Hard Drive to the Hard Drive Tray
1.
Slide the drive tray into an empty slot in the chassis.
2.
Close the drive tray handle until it clicks into place.
Note: Replacing a failed hard drive requires manual configuration steps to be taken in the admin console.
See the Administration Guide for more information at https://www.pulsesecure.net/techpubs.
© 2017 Pulse Secure, LLC. All rights reserved
28
PSA7000 Hardware Guide
Replacing Power Supplies
The PSA7000 chassis has a 700 Watt power supply. This power supply is auto-switching capable. This enables
it to automatically sense and operate at a 100v to 240v input voltage. An amber light will be illuminated on the
power supply when the power is off. An illuminated green light indicates that the power supply is operating.
The PSA7000 chassis includes a redundant power supply. Power supplies can be replaced without powering
down the system. Replacement units can be ordered directly from Pulse Secure.
Release Tab
The PSA7000 chassis includes a redundant power supply. It is not necessary to power down the server to
replace a power supply. PWR1 and PWR2 are labeled in the graphic below:
Replacing the Power Supply
1.
Push the Release tab (on the back of the power supply) as illustrated.
2.
Pull the power supply out using the handle provided.
© 2017 Pulse Secure, LLC. All rights reserved
29
PSA7000 Hardware Guide
3.
Replace the failed power module with a new unit. To do this, push the new power supply module into
the power bay until you hear a click.
4.
Plug the AC power cord back into the module.
Network Cables
The PSA7000f model offers SFP+ interfaces supporting both 10G fiber and 10G copper networks with a direct
attach transceiver cable.
PSA7000f
This appliance offer dual and redundant 10G network interface ports (4 ports total) in the SFP+ form factor.
Pulse Secure has qualified SFP+/Cable combinations (Short Range, 850 nm) and offers them for sale as an
optional accessory. Check the Price book for the SKUs.
Customers can either purchase this option from Pulse Secure or procure it from their vendor of choice.
Contact your Solutions Engineer or Technical Support for additional information and Technical Specifications.
The performance tests done with Finisar (Juniper) transceiver on the cable end that is connected to the
Juniper switch, and Avago transceiver on the cable end that is connected to the PSA 7000 show no impact on
the throughput using longer cables. The maximum cable length qualified is 15 meters.
Note: The cable included with 10G transceiver will only work with 10G switch port.
© 2017 Pulse Secure, LLC. All rights reserved
30
PSA7000 Hardware Guide
Support for 1G Network:
•
The Network interface card in the PSA7000f is designed for 10G networks, but it can support 1G networks
when used with 1G transceivers at both ends of the network. No manual set up is required. Pulse Secure
does not offer any optional 1G transceiver / cable as an option for sale. Any supplier’s short range 1G
transceiver should work.
•
http://www.avagotech.com/products/fiber-optics/optical-transceivers/sfp/abcu-5741rz
The tested and qualified cables details are provided in the table below.
Brand
Length
Finisar (Juniper) transceiver
15 meters
Avago transceiver
15 meters
PSA7000c
This appliance offers dual and redundant 10G network interface ports (4 ports total) in the RJ45 form
factor compatible with category 6 or 6A network cables.
The hardware supports auto-negotiation between 1G and 10G networks over an RJ45 connection. Pulse
secure does not offer any RJ45 cables/accessories as an optional SKU.
Serial Number Placement
The serial number is placed on the bottom left edge of the unit. See the red box in the graphic. When
technicians service the system from the rear of the cabinet, they can scan the barcode easily (especially if the
rackmount unit is at the bottom of the cabinet):
Serial numbers are also displayed in the LCD for the PSA7000.
© 2017 Pulse Secure, LLC. All rights reserved
31
PSA7000 Hardware Guide
Standard Warnings and Compliance
About Standard Warnings
The following statements are industry standard warnings, provided to warn the user of situations that have
the potential for bodily injury. Should you have questions or have trouble, contact Pulse Secure's
Technical Support department for assistance. Only certified technicians should attempt to install or configure
components.
Safety Certifications
•
USA - UL listed, FCC
•
Canada - CUL listed
•
Germany - TUV Certified
•
Europe/CE Mark
•
EN 60950/IEC 60950-Compliant
•
CCC Exemption
Electrical Safety
Basic electrical safety precautions should be followed to protect yourself from harm and the system from
damage:
•
Be aware of the locations of the power on/off switch on the system, as well as the room’s emergency
power-off switch, disconnection switch, or electrical outlet. If an electrical accident occurs, you can quickly
remove power from the system.
•
Do not work alone when working with high voltage components.
•
Power should always be disconnected from the system when removing or installing system components.
When disconnecting power, you should first power down the system with the operating system and then
unplug the power cords from all the power supply modules in the system.
•
When working around exposed electrical circuits, another person who is familiar with the power-off controls
should be nearby to switch off the power, if necessary.
© 2017 Pulse Secure, LLC. All rights reserved
32
PSA7000 Hardware Guide
•
Use only one hand when working with powered-on electrical equipment. This is to avoid making a complete
circuit, which will cause electrical shock. Use extreme caution when using metal tools, which can easily
damage any electrical components they come into contact with.
•
Do not use mats designed to decrease electrostatic discharge as protection from electrical shock. Instead,
use rubber mats that have been specifically designed as electrical insulators.
•
The power supply power cord must include a grounding plug and must be plugged into grounded electrical
outlets.
•
Use a grounded wrist strap designed to prevent static discharge.
General Safety
•
Keep the area around the system clean and free of clutter.
•
While working on the system, do not wear loose clothing such as neckties and unbuttoned shirt sleeves,
which can come into contact with electrical circuits or be pulled into a fan.
•
Remove any jewelry or metal objects from your body, which are excellent metal conductors that can create
short circuits and harm you if they come into contact with areas where power is present.
Warning!
This warning symbol means danger. You are in a situation that could cause bodily injury. Before you work
on any equipment, be aware of the hazards involved with electrical circuitry and be familiar with standard
practices for preventing accidents.
警告の定義
この警告サインは危険を意味します。
人身事故につながる可能性がありますので、いずれの機器でも動作させる前に、
電気回路に含まれる危険性に注意して、標準的な事故防止策に精通して下さい。
此警告符号代表危 。
您正处于可能受到 重 害的工作环境中。在您使用
每 警告 尾的声明号 找到此
始工作之前,必 充分意 到触 的危 ,并熟 掌握防止事故 生的 准工作程序。 根据
的安全性警告 明的翻 文本。
此警告符號代表危險。
您正處於可能身體可能會受損傷的工作環境中。在您使用任何設備之前,請注意觸電的危險,並且要熟悉預防事故發生的標準工作程序。請
依照每一注意事項後的號碼找到相關的翻譯說明內容。
© 2017 Pulse Secure, LLC. All rights reserved
33
PSA7000 Hardware Guide
Warnung
WICHTIGE SICHERHEITSHINWEISE
Dieses Warnsymbol bedeutet Gefahr. Sie befinden sich in einer Situation, die zu Verletzungen führen kann.
Machen Sie sich vor der Arbeit mit Geräten mit den Gefahren elektrischer Schaltungen und den üblichen
Verfahren zur Vorbeugung vor Unfällen vertraut. Suchen Sie mit der am Ende jeder Warnung angegebenen
Anweisungsnummer nach der jeweiligen Übersetzung in den übersetzten Sicherheitshinweisen, die zusammen
mit diesem Gerät ausgeliefert wurden.
BEWAHREN SIE DIESE HINWEISE GUT AUF.
INSTRUCCIONES IMPORTANTES DE SEGURIDAD
Este símbolo de aviso indica peligro. Existe riesgo para su integridad física. Antes de manipular cualquier
equipo, considere los riesgos de la corriente eléctrica y familiarícese con los procedimientos estándar de
prevención de accidentes. Al final de cada advertencia encontrará el número que le ayudará a encontrar el
texto traducido en el apartado de traducciones que acompaña a este dispositivo.
GUARDE ESTAS INSTRUCCIONES.
IMPORTANTES INFORMATIONS DE SÉCURITÉ
Ce symbole d'avertissement indique un danger. Vous vous trouvez dans une situation pouvant entraîner des
blessures ou des dommages corporels. Avant de travailler sur un équipement, soyez conscient des dangers
liés aux circuits électriques et familiarisez-vous avec les procédures couramment utilisées pour éviter les
accidents. Pour prendre connaissance des traductions des avertissements figurant dans les consignes de
sécurité traduites qui accompagnent cet appareil, référez-vous au numéro de l'instruction situé à la fin de
chaque avertissement.
CONSERVEZ CES INFORMATIONS.
‫תקנון הצהרות אזהרה‬
‫ על מנת להזהיר את המשתמש מפני חבלה‬,‫הצהרות הבאות הן אזהרות על פי תקני התעשייה‬
‫ יש ליצור קשר עם מחלקת תמיכה‬,‫ במידה ויש שאלות או היתקלות בבעיה כלשהי‬.‫פיזית אפשרית‬
‫ טכנאים מוסמכים בלבד רשאים להתקין או להגדיר את הרכיבים‬.‫טכנית של סופרמיקרו‬.
‫יש לקרוא את הנספח במלואו לפני התקנת או הגדרת הרכיבים במארזי סופרמיקרו‬.
© 2017 Pulse Secure, LLC. All rights reserved
34
PSA7000 Hardware Guide
‫ تعول‬. ‫تحذز!هذا الزهز ٌعٌٌ خطز اٌك ف حالة ٌوكي أى تتسبب ف اصابة جسذٌة‬
‫كي على علن بالوخاطز اٌلجوة عي الذوائز قبل أى‬،‫على أي هعذات‬
‫الكهزبائٌة‬
‫وكي على دراٌة بالووارسات الىقائٌة لوٌع وقىع أي حىادث استخذم‬
‫رقن البٌاى الوٌصىص فٌ ٌهاٌة كل تحذٌز للعثىر تزجوتها‬
안전을 위한 주의사항
경고!
이 경고 기호는 위험이 있음을 알려 줍니다. 작업자의 신체에 부상을 야기 할 수 있는 상태에 있게 됩니다. 모든 장비에 대한 작업을
수행하기 전에 전기회로와 관련된 위험요소들을 확인하시고 사전에 사고를 방지할 수 있도록 표준 작업절차를 준수해 주시기 바랍니다.
해당 번역문을 찾기 위해 각 경고의 마지막 부분에 제공된 경고문 번호를 참조하십시오
BELANGRIJKE VEILIGHEIDSINSTRUCTIES
Dit waarschuwings symbool betekent gevaar. U verkeert in een situatie die lichamelijk letsel kan veroorzaken.
Voordat u aan enige apparatuur gaat werken, dient u zich bewust te zijn van de bij een elektrische installatie
betrokken risico's en dient u op de hoogte te zijn van de standaard procedures om ongelukken te voorkomen.
Gebruik de nummers aan het eind van elke waarschuwing om deze te herleiden naar de desbetreffende
locatie.
BEWAAR DEZE INSTRUCTIES
© 2017 Pulse Secure, LLC. All rights reserved
35
PSA7000 Hardware Guide
Installation Instructions
Warning!
Read the installation instructions before connecting the system to the power source.
設置手順書
システムを電源に接続する前に、設置手順書をお読み下さい。
警告
将此系
接 源前, 先
安
明。
警告
將系統與電源連接前,請先閱讀安裝說明。
Warnung
Vor dem Anschließen des Systems an die Stromquelle die Installationsanweisungen lesen.
¡Advertencia!
Lea las instrucciones de instalación antes de conectar el sistema a la red de alimentación.
Attention
Avant de brancher le système sur la source d'alimentation, consulter les directives d'installation.
‫יש לקרוא את הוראות התקנה לפני חיבור המערכת למקור מתח‬.
‫اقر إرشادات التركيب قبل توصيل النظام إلى مصدر للطاقة‬
시스템을 전원에 연결하기 전에 설치 안내를 읽어주십시오.
Waarschuwing
Raadpleeg de installatie-instructies voordat u het systeem op de voedingsbron aansluit.
© 2017 Pulse Secure, LLC. All rights reserved
36
PSA7000 Hardware Guide
Circuit Breaker
Warning!
This product relies on the building's installation for short-circuit (overcurrent) protection. Ensure that the
protective device is rated not greater than: 250 V, 20 A.
サーキット・ブレーカー
この製品は、短絡(過電流)保護装置がある建物での設置を前提としています。
保護装置の定格が250 V、20 Aを超えないことを確認下さい。
警告
此 品 的 短 路 ( 过 流 )保 由 建 筑 物 的 供 系 提 供 , 确 保 短 路 保
流不大于250V,20A。
的 定
警告
此產品的短路(過載電流)保護由建築物的供電系統提供,確保短路保護設備的額定電
流不大於250V,20A。
Warnung
Dieses Produkt ist darauf angewiesen, dass im Gebäude ein Kurzschluss- bzw. Überstromschutz installiert ist.
Stellen Sie sicher, dass der Nennwert der Schutzvorrichtung nicht mehr als: 250 V, 20 A beträgt.
¡Advertencia!
Este equipo utiliza el sistema de protección contra cortocircuitos (o sobrecorrientes) del edificio. Asegúrese
de que el dispositivo de protección no sea superior a: 250 V, 20 A.
Attention
‫יש לוודא כי‬. ‫מוצר זה מסתמך על הגנה המותקנת במבנים למניעת קצר חשמלי‬
‫המכשיר המגן מפני הקצר החשמלי הוא לא יותר מ‬A- 20 V, 250
‫هذا المنتج يعتمد على معداث الحمايت مه الدوائرالقصيرة التي تم تثبيتها في‬
‫المبنى‬
250 :‫تأكد من أن تقييم الجهاز الوقائي ليس أكثر من‬V 20A,
© 2017 Pulse Secure, LLC. All rights reserved
37
PSA7000 Hardware Guide
경고!
이 제품은 전원의 단락(과전류)방지에 대해서 전적으로 건물의 관련 설비에 의존합니다. 보호장치의 정격이 반드시 250V(볼트), 20A(
암페어)를 초과하지 않도록 해야 합니다.
Waarschuwing
Dit product is afhankelijk van de kortsluitbeveiliging (overspanning) van uw electrische installatie. Controleer
of het beveiligde aparaat niet groter gedimensioneerd is dan 220V, 20A.
Power Disconnection Warning
Warning!
The system must be disconnected from all sources of power and the power cord removed from the power
supply module(s) before accessing the chassis interior to install or remove system components.
電源切断の警告
システムコンポーネントの取り付けまたは取り外しのために、
シャーシー内部にアクセスするには、
システムの電源はすべてのソースから切断され、電源コードは電源モジュールから取り外す必要があります。
警告
在你打 机箱并安 或移除内部器件前,必 将系 完全断 ,并移除 源 。
警告
在您打開機殼安裝或移除內部元件前,必須將系統完全斷電,並移除電源線。
Warnung
Das System muss von allen Quellen der Energie und vom Netzanschlusskabel getrennt sein, das von
den Spg.Versorgungsteilmodulen entfernt wird, bevor es auf den Chassisinnenraum zurückgreift, um
Systemsbestandteile anzubringen oder zu entfernen.
© 2017 Pulse Secure, LLC. All rights reserved
38
PSA7000 Hardware Guide
¡Advertencia!
El sistema debe ser disconnected de todas las fuentes de energía y del cable eléctrico quitado de los módulos
de fuente de alimentación antes de tener acceso el interior del chasis para instalar o para quitar componentes
de sistema.
Attention
Le système doit être débranché de toutes les sources de puissance ainsi que de son cordon d'alimentation
secteur avant d'accéder à l'intérieur du chassis pour installer ou enlever des composants de systéme.
!‫אזהרה‬
‫יש לנתק את המערכת מכל מקורות החשמל ויש להסיר את כבל החשמלי מהספק‬
‫לפני גישה לחלק הפנימי של המארז לצורך התקנת או הסרת רכיבים‬.
‫يجب فصم اننظاو من جميع مصادر انطاقت وإزانت سهك انكهرباء من وحدة امداد‬
‫انطاقت قبم‬
‫انىصىل إنى انمناطق انداخهيت نههيكم نتثبيج أو إزانت مكىناث الجهاز‬
경고!
시스템에 부품들을 장착하거나 제거하기 위해서는 섀시 내부에 접근하기 전에 반드시 전원 공급장치로부터 연결되어있는 모든 전원과
전기코드를 분리해주어야 합니다.
Waarschuwing
Voordat u toegang neemt tot het binnenwerk van de behuizing voor het installeren of verwijderen van
systeem onderdelen, dient u alle spanningsbronnen en alle stroomkabels aangesloten op de voeding(en)
van de behuizing te verwijderen
© 2017 Pulse Secure, LLC. All rights reserved
40
PSA7000 Hardware Guide
Equipment Installation
Warning!
Only trained and qualified personnel should be allowed to install, replace, or service this equipment.
機器の設置
トレーニングを受け認定された人だけがこの装置の設置、交換、
またはサービスを許可されています。
警告
只有 过培 且具有 格的人 才能 行此
的安 、更 和 修。
警告
只有經過受訓且具資格人員才可安裝、更換與維修此設備。
Warnung
Das Installieren, Ersetzen oder Bedienen dieser Ausrüstung sollte nur geschultem, qualifiziertem Personal
gestattet werden.
¡Advertencia!
Solamente el personal calificado debe instalar, reemplazar o utilizar este equipo.
‫!אזהרה‬
‫ להחליף את הציוד או לתת שירות עבור הציוד‬,‫צוות מוסמך בלבד רשאי להתקין‬.
‫لتزكيب واستبدال أو خدمة هذا الجهاس‬
‫يجب أن يسمح فقط للمىظفيه المؤهليه والمدربيه‬
경고!
훈련을 받고 공인된 기술자만이 이 장비의 설치, 교체 또는 서비스를 수행할 수 있습니다.
© 2017 Pulse Secure, LLC. All rights reserved
41
PSA7000 Hardware Guide
Waarschuwing
Deze apparatuur mag alleen worden geïnstalleerd, vervangen of hersteld door geschoold en gekwalificeerd
personeel.
Restricted Area
Warning!
This unit is intended for installation in restricted access areas. A restricted access area can be accessed only
through the use of a special tool, lock and key, or other means of security. (This warning does not apply to
workstations).
アクセス制限区域
このユニットは、
アクセス制限区域に設置されることを想定しています。
アクセス制限区域は、特別なツール、鍵と錠前、
その他のセキュリティの手段を用いてのみ出入りが可能です。
警告
此部件 安 在限制 出的 所,限制 出的 所指只能通过使用特殊工具、 和 匙或其它安全手段 出的 所。
警告
此裝置僅限安裝於進出管制區域,進出管制區域係指僅能以特殊工具、鎖頭及鑰匙或其他安全方式才能進入的區域。
© 2017 Pulse Secure, LLC. All rights reserved
42
PSA7000 Hardware Guide
Warnung
Diese Einheit ist zur Installation in Bereichen mit beschränktem Zutritt vorgesehen. Der Zutritt zu
derartigen Bereichen ist nur mit einem Spezialwerkzeug, Schloss und Schlüssel oder einer sonstigen
Sicherheitsvorkehrung möglich.
¡Advertencia!
Esta unidad ha sido diseñada para instalación en áreas de acceso restringido. Sólo puede obtenerse acceso
a una de estas áreas mediante la utilización de una herramienta especial, cerradura con llave u otro medio
de seguridad.
Attention
Cet appareil doit être installée dans des zones d'accès réservés. L'accès à une zone d'accès réservé n'est
possible qu'en utilisant un outil spécial, un mécanisme de verrouillage et une clé, ou tout autre moyen de
sécurité.
‫אזור עם גישה מוגבלת‬
!‫אזהרה‬
‫הגישה ניתנת בעזרת‬. ‫יש להתקין את היחידה באזורים שיש בהם הגבלת גישה‬
.)‫ מנעול וכד‬,‫'כלי אבטחה בלבד (מפתח‬
‫ تم تخصيص هذه انىحذة نتر ُكبها ف مناطق محظورة‬.
ٌ‫مكن انىصىل إن منطقت محظورة فقط من خالل استخذاو أداة خاصت‬،
‫قفم ومفتاح أو أ وسُهت أخري نالمألما‬
경고!
이 장치는 접근이 제한된 구역에 설치하도록 되어있습니다. 특수도구, 잠금 장치 및 키, 또는 기타 보안 수단을 통해서만 접근 제한 구역에
들어갈 수 있습니다.
Waarschuwing
Dit apparaat is bedoeld voor installatie in gebieden met een beperkte toegang. Toegang tot dergelijke
gebieden kunnen alleen verkregen worden door gebruik te maken van speciaal gereedschap, slot en sleutel
of andere veiligheidsmaatregelen.
© 2017 Pulse Secure, LLC. All rights reserved
43
PSA7000 Hardware Guide
Redundant Power Supplies
冗長電源装置
このユニットは複数の電源装置が接続されている場合があります。
ユニットの電源を切るためには、すべての接続を取り外さなければなりません。
警告
此部件 接的 源可能不止一个,必 将所有 源断 才能停止
部件供 。
警告
此裝置連接的電源可能不只一個,必須切斷所有電源才能停止對該裝置的供電。
Warnung
Dieses Gerät kann mehr als eine Stromzufuhr haben. Um sicherzustellen, dass der Einheit kein trom zugeführt
wird, müssen alle Verbindungen entfernt werden.
¡Advertencia!
Puede que esta unidad tenga más de una conexión para fuentes de alimentación. Para cortar por completo
el suministro de energía, deben desconectarse todas las conexiones.
Attention
Cette unité peut avoir plus d'une connexion d'alimentation. Pour supprimer toute tension et tout courant
électrique de l'unité, toutes les connexions d'alimentation doivent être débranchées.
‫אם קיים יותר מספק אחד‬
!‫אזהרה‬
‫ יש להסיר את כל החיבורים על מנת לרוקן‬.‫ליחדה יש יותר מחיבור אחד של ספק‬
‫את היחידה‬.
© 2017 Pulse Secure, LLC. All rights reserved
44
PSA7000 Hardware Guide
‫يجب إزالة كافة االتصاالت لعسل الوحدة عن الكهرباء قد يكون‬
‫لهذا الجهاز عدة اتصاالت بوحدات امداد الطاقة‬.
경고!
이 장치에는 한 개 이상의 전원 공급 단자가 연결되어 있을 수 있습니다. 이 장치에 전원을 차단하기 위해서는 모든 연결 단자를
제거해야만 합니다.
Waarschuwing
Backplane Voltage
Warning!
Hazardous voltage or energy is present on the backplane when the system is operating. Use caution when
servicing.
バックプレーンの電圧
システムの稼働中は危険な電圧または電力が、バックプレーン上にかかっています。
修理する際には注意ください。
警告
当系 正在 行时,背板上有很危 的 压或能量, 行 修时 必小心。
警告
當系統正在進行時,背板上有危險的電壓或能量,進行維修時務必小心。
Warnung
Wenn das System in Betrieb ist, treten auf der Rückwandplatine gefährliche Spannungen oder Energien auf.
Vorsicht bei der Wartung.
¡Advertencia!
Cuando el sistema está en funcionamiento, el voltaje del plano trasero es peligroso. Tenga cuidado cuando
lo revise.
Attention
Lorsque le système est en fonctionnement, des tensions électriques circulent sur le fond de panier. Prendre
des précautions lors de la maintenance.
© 2017 Pulse Secure, LLC. All rights reserved
45
PSA7000 Hardware Guide
‫מתח בפנל האחורי‬
!‫אזהרה‬
‫ יש להיזהר במהלך‬.‫קיימת סכנת מתח בפנל האחורי בזמן תפעול המערכת‬
‫העבודה‬.
‫خطز مه التيار الكهزبائي أوالطاقة المىجىدة على اللىحة النظام يعمل كه حذرا‬
‫عند خدمة هذا الجهاس هناك عندما يكىن‬
경고!
시스템이 동작 중일 때 후면판 (Backplane)에는 위험한 전압이나 에너지가 발생 합니다. 서비스 작업 시 주의하십시오.
Waarschuwing
Een gevaarlijke spanning of energie is aanwezig op de backplane wanneer het systeem in gebruik is.
Voorzichtigheid is geboden tijdens het onderhoud.
Comply with Local and National Electrical Codes
Warning!
Installation of the equipment must comply with local and national electrical codes.
地方および国の電気規格に準拠
機器の取り付けはその地方および国の電気規格に準拠する必要があります。
警告
安 必 符合本地与本国 气法 。
警告
Warnung
Die Installation der Geräte muss den Sicherheitsstandards entsprechen.
¡Advertencia!
La instalacion del equipo debe cumplir con las normas de electricidad locales y nacionales.
© 2017 Pulse Secure, LLC. All rights reserved
46
PSA7000 Hardware Guide
Attention
L'équipement doit être installé conformément aux normes électriques nationales et locales.
‫תיאום חוקי החשמל הארצי‬
‫!אזהרה‬
‫התקנת הציוד חייבת להיות תואמת לחוקי החשמל המקומיים והארציים‬.
‫تركيب المعدات الكهربائية يجب أن يمتثل للقىاويه المحلية والىطىية المتعلقة‬
‫بالكهرباء‬
경고!
현 지역 및 국가의 전기 규정에 따라 장비를 설치해야 합니다.
Waarschuwing
Product Disposal
Warning!
Ultimate disposal of this product should be handled according to all national laws and regulations.
製品の廃棄
この製品を廃棄処分する場合、国の関係する全ての法律・条例に従い処理する必要があります。
警告
本 品的 弃处理 根据所有国家的法律和 章 行。
警告
本產品的廢棄處理應根據所有國家的法律和規章進行。
Warnung
Die Entsorgung dieses Produkts sollte gemäß allen Bestimmungen und Gesetzen des Landes erfolgen.
© 2017 Pulse Secure, LLC. All rights reserved
47
PSA7000 Hardware Guide
¡Advertencia!
Al deshacerse por completo de este producto debe seguir todas las leyes y reglamentos nacionales.
Attention
La mise au rebut ou le recyclage de ce produit sont généralement soumis à des lois et/ou directives de
respect de l'environnement. Renseignez-vous auprès de l'organisme compétent.
‫סילוק המוצר‬
‫!אזהרה‬
‫סילוק סופי של מוצר זה חייב להיות בהתאם להנחיות וחוקי המדינה‬.
‫عند التخلص النهائي من هذا المنتج ينبغي التعامل معه وفقا لجميع القىانين واللىائح الىطنية‬
경고!
이 제품은 해당 국가의 관련 법규 및 규정에 따라 폐기되어야 합니다.
Hot Swap Fan Warning
Waarschuwing
De uiteindelijke verwijdering van dit product dient te geschieden in overeenstemming met alle nationale
wetten en reglementen.
Warning!
The fans might still be turning when you remove the fan assembly from the chassis. Keep fingers, screwdrivers,
and other objects away from the openings in the fan assembly's housing.
ファン・ホットスワップの警告
シャーシから冷却ファン装置を取り外した際、
ファンがまだ回転している可能性があります。ファンの開口部に、指、
ドライバー、
およびその他のも
のを近づけないで下さい。
警告
当您从机架移除 扇 置, 扇可能仍在 动。小心不要将手指、螺 起子和其他物品太靠近 扇
警告
© 2017 Pulse Secure, LLC. All rights reserved
48
PSA7000 Hardware Guide
當您從機架移除風扇裝置,風扇可能仍在轉動。小心不要將手指、螺絲起子和其他物品太靠近風扇。
Warnung
Die Lüfter drehen sich u. U. noch, wenn die Lüfterbaugruppe aus dem Chassis genommen wird. Halten Sie
Finger, Schraubendreher und andere Gegenstände von den Öffnungen des Lüftergehäuses entfernt.
¡Advertencia!
Los ventiladores podran dar vuelta cuando usted quite ell montaje del ventilador del chasis. Mandtenga los
dedos, los destornilladores y todos los objetos lejos de las aberturas del ventilador
Attention
Il est possible que les ventilateurs soient toujours en rotation lorsque vous retirerez le bloc ventilateur
du châssis. Prenez garde à ce que doigts, tournevis et autres objets soient éloignés du logement du bloc
ventilateur.
!‫אזהרה‬
‫ יש‬.‫ יתכן והמאווררים עדיין עובדים‬,‫כאשר מסירים את חלקי המאוורר מהמארז‬
‫להרחיק למרחק בטוח את האצבעות וכלי עבודה שונים מהפתחים בתוך המאוורר‬
‫مه انممكه أن انمراوح ال تسال تدورعند إزانة كتهة انمروحة مه انهيكم يجب إبقاء‬
‫األصابع ومفكات انبراغي‬
‫وغيرها مه األشياء بعيدا عه انفتحات في كتهة انمروحة‬.
경고!
섀시로부터 팬 조립품을 제거할 때 팬은 여전히 회전하고 있을 수 있습니다. 팬 조림품 외관의 열려있는 부분들로부터 손가락 및
스크류드라이버, 다른 물체들이 가까이 하지 않도록 배치해 주십시오.
Waarschuwing
Het is mogelijk dat de ventilator nog draait tijdens het verwijderen van het ventilatorsamenstel uit het chassis.
Houd uw vingers, schroevendraaiers en eventuele andere voorwerpen uit de buurt van de openingen in de
ventilatorbehuizing.
© 2017 Pulse Secure, LLC. All rights reserved
49
PSA7000 Hardware Guide
Power Cable and AC Adapter
Warning!
When installing the product, use the provided or designated connection cables, power cables and AC
adaptors. Using any other cables and adaptors could cause a malfunction or a fire. Electrical Appliance and
Material Safety Law prohibits the use of UL or CSA -certified cables (that have UL/CSA shown on the code)
for any other electrical devices than products designated by Supermicro only.
電源コードとACアダプター
製品を設置する場合、提供または指定された接続ケーブル、電源コードとACアダプターを使用下さい。他のケーブルやアダプタを使用すると故障
や火災の原因になることがあります。電気用品安全法は、ULまたはCSA認定のケーブル(UL/CSEマークがコードに表記)を Pulse Secure が指定
する製品以外に使用することを禁止しています。
警告
安 此 品时, 使用本身提供的或指定的 接 , 源 和 源适配器.使用其它 材或适配器可能会引起故障或火灾。除了Pulse
所指定的 品, 气用品和材料安全法律 定禁止使用未 UL或CSA 的 材。( 材上会 示UL/CSA符号)。
Secure
警告
安裝此產品時,請使用本身提供的或指定的連接線,電源線和電源適配器.使用其它線材或適配器可能會引起故障或火災。除了Pulse Secure
所指定的產品,電氣用品和材料安全法律規定禁止使用未經UL或CSA認證的線材。(線材上會顯示UL/CSA符號)。
Warnung
Bei der Installation des Produkts, die zur Verfügung gestellten oder benannt Anschlusskabel, Stromkabel und
Netzteile. Verwendung anderer Kabel und Adapter kann zu einer Fehlfunktion oder ein Brand entstehen.
Elektrische Geräte und Material Safety Law verbietet die Verwendung von UL-oder CSA-zertifizierte Kabel, UL
oder CSA auf der Code für alle anderen elektrischen Geräte als Produkte von Pulse Secure nur bezeichnet
gezeigt haben.
¡Advertencia!
Al instalar el producto, utilice los cables de conexión previstos o designados, los cables y adaptadores de
CA. La utilización de otros cables y adaptadores podría ocasionar un mal funcionamiento o un incendio.
Aparatos Eléctricos y la Ley de Seguridad del Material prohíbe el uso de UL o CSA cables certificados que
tienen UL o CSA se muestra en el código de otros dispositivos eléctricos que los productos designados por
Pulse Secure solamente.
© 2017 Pulse Secure, LLC. All rights reserved
50
PSA7000 Hardware Guide
Attention
Lors de l'installation du produit, utilisez les bables de connection fournis ou désigné. L'utilisation d'autres
cables et adaptateurs peut provoquer un dysfonctionnement ou un incendie. Appareils électroménagers et
de loi sur la sécurité Matériel interdit l'utilisation de UL ou CSA câbles certifiés qui ont UL ou CSA indiqué
sur le code pour tous les autres appareils électriques que les produits désignés par Pulse Secure seulement.
‫חשמליים ומתאמי‬
AC
‫!אזהרה‬
‫ספקים ומתאמים‬, ‫ יש להשתמש בכבלים‬,‫ מתקינים את המוצר‬AC ‫אשר לשם‬
‫ שימוש בכל כבל או מתאם אחר יכול לגרום לתקלה או כאשר על פי חוקי‬.‫כך‬
‫ קיים איסור נועדו וסופקו קצר‬,‫שימוש במכשירי חשמל וחוקי בטיחות‬
‫חשמלי‬.
(‫להשתמש בכבלים המוסמכים ב כשאר מופיע עליהם קוד של‬- UL ‫או ב‬- CSA
)UL/CSA ‫עבור כל מוצר חשמלי אחר שלא צוין על ידי סופרקמיקרו בלבד‬.
Pulse Secure
경고!
제품을 설치할 때에는 제공되거나 지정된 연결케이블과 전원케이블, AC어댑터를 사용해야 합니다. 그 밖의 다른 케이블들이나
어댑터들은 고장 또는 화재의 원인이 될 수 있습니다. 전기용품안전법 (Electrical Appliance and Material Safety Law)은
슈퍼마이크로에서 지정한 제품들 외에는 그 밖의 다른 전기 장치들을 위한 UL또는 CSA에서 인증한 케이블(전선 위에 UL/CSA가 표시)
들의 사용을 금지합니다.
Waarschuwing
Bij het installeren van het product, gebruik de meegeleverde of aangewezen kabels, stroomkabels en adapters.
Het gebruik van andere kabels en adapters kan leiden tot een storing of een brand. Elektrisch apparaat en
veiligheidsinformatiebladen wet verbiedt het gebruik van UL of CSA gecertificeerde kabels die UL of CSA die
op de code voor andere elektrische apparaten dan de producten die door Pulse Secure alleen.
© 2017 Pulse Secure, LLC. All rights reserved
51
PSA7000 Hardware Guide
Certification Statements
Japan
この装置は、
クラス A 情報技術装置です。
この装置を家庭環境で使用すると電波妨害
を引き起こすことがあります。
この場合には使用者が適切な対策を講ずるよう要求され
ることがあります。VCCI-A
Israel
Saudi Arabia
Complies with the CITC Technical Specification CITC GEN001, IT001.
South Korea
이 기기는 업무용(A급) 전자파 적합기기로서 판매자 또는 사용자는 이 점을 주의하시기 바라며,
가정외의 지역에서 사용하는 것을 목적으로 합니다.
Taiwan
警告使用者:這是甲類的資訊產品,在居住的環境中使用時,
可能會造成射頻干擾,在這種情況下,使用者會被要求採取某
些適當的對策
© 2017 Pulse Secure, LLC. All rights reserved
52
PSA7000 Hardware Guide
Thailand
เครือ่ งโทรคมนาคม และอุปกรณ์น้ี มีความสอดคล้องตามข้อกาหนดของ กทช.
© 2017 Pulse Secure, LLC. All rights reserved
53
Download PDF