MIC1100S
Technical Data Sheet
MIC1100S Multi Information Controller










10/100BaseT Ethernet
3x CAN interfaces
2x USB Interfaces
2x RS232
4x Video Inputs
40 configurable I/O’s
2x Display connectors
Programmable via
Guitu
Designed for operation
at both 12V and 24V
Real Time Clock
The MIC1100S is embedded Linux based high end controller with
loads of features. It combines the traditional I/O controller, Display
controller and Data logger with rich set of interfaces such as USB,
Ethernet, RS232 and CAN interfaces. It also enables showing
multiple camera pictures on attached remote display(s).
Optionally it can be equipped with RF interface or with an internal
SD memory card. It is commonly used as NMT master for machine
automation systems. It can store and transfer the application to
nodes in the system making maintenance easier.
MIC1100S
09JAN2017
2/7
Technical Information














9-32V Operating voltage range
(Protected against reverse polarity)
-40…+85°C operating temperature range
32-bit microprocessor
128MB RAM
256MB flash memory
IP67 aluminium housing
Weight 1.3kg
Main dimensions 145mm x 195mm x 35mm
2x CAN Interface 2.0 B, ISO 11898
1x CAN Interface 2.0 B Isolated, ISO 11898
2x Serial port interface RS232
Battery secured real time clock (RTC)
Internal SD memory card slot (up to SDHC 32GB supported)
Optional radio frequency interface
I/O Interface
 Total of 40 configurable IO-lines
 Separate supply for outputs and electronics
 The I/O interface is protected against short to GND and to
supply voltage
 Configurable reference voltage: 5V / 10V, max 250mA
Amount
Configurability
Details
8
Digital input
Low<3.5V, High>5V, max 100Hz
8
Digital input
Analog input
Low<3.5V, High>5V, max 100Hz
12-bit AD conv.,
0-5.2V, 129kΩ
0-22mA, 150Ω
8
Digital input
Frequency/pulse input
Low<3.5V, High>5V, max 100Hz
Low<3.5V, High>5V, max 8kHz
16
Digital input
Digital output
Current controlled PWM output
Low<3.5V, High>5V, max 100Hz
High side switch, max 2.7A
High side switch, max 2.7A
MIC1100S
09JAN2017
3/7
Wiring Diagram for M12 connectors (X1 through to X9):
Supply for electronics *)
1A fuse recommended
and
CAN1
Remote Display
Touch screen
Remote Display
CAN2
4x Composite Video Input
CAN3
Isolated
and
Supply for CAN3
USB
10/100 BaseT Ethernet
DHCP / Zeroconf
2x RS232
*) Supply to electronics
is to be done either over
X1_2 (M12 connector) or
X10_13 (AMP connector),
never over both.
MIC1100S
09JAN2017
4/7
Wiring Diagram for AMP Superseal Connectors (X10 and X11):
Supply for Outputs
15A fuse recommended
Analog inputs
12-bit resolution
Overload protection
0-5.2V / 0-22mA
or
Digital inputs
Reference voltage out
250mA
Digital inputs
or
PWM Outputs
- with current measurement
- High side driver, Max 2,7A
CAN 1
Digital inputs
Supply for electronics *)
1A fuse recommended
Digital inputs
or
Frequency/pulse inputs
USB 2
Digital input
or
Frequency/pulse input
*) Supply to electronics
is to be done either over
X1_2 (M12 connector) or
X10_13 (AMP connector),
never over both.
MIC1100S
09JAN2017
5/7
Connectors
X2
RF int.
X1, X3, X4
X7
X10
X9
X11
X5, X7
X5
X6
X4
X3
X2
X1
X8
X6
M12 Connectors
X1 : CAN 1 + Power Supply
X2 : Serial Interface 1 & 2
X3 : CAN 2
X4 : CAN 3
X5 : USB 1
X6 : Ethernet
X7 : Composite Video Inputs 1 – 4
X8 : Remote Display
X9 : Remote Touch Display
Protective cap for Male M12 *)
Protective cap for Female M12 *)
M12 Connector needed:
5 pin, Female A-coded
8 pin, Female A-coded
5 pin, Female A-coded
5 pin, Female A-coded
5 pin, Male A-coded
4 pin, Female A-coded
5 pin, Male A-coded
4 pin, Male D-coded
4 pin, Male D-coded
Erni 374342
Erni 374343
X8, X9
1
7
20
26
X10
*) Protective caps must be used on unused connectors to reach waterproofness
Tyco Electronics Superseal Connectors
X10 : Super Seal Connector Plug Housing
X11 : Super Seal Connector Plug Housing
Receptacle Contact (0.75 – 1.25mm2)
Filler Plug *)
Superseal connector needed:
Ø1.6-2.2mm - AMP 3-1437290-7
Ø1.6-2.2mm - AMP 3-1437290-8
AMP 3-1447221-3
AMP 4-1437284-3
Deutsch 0413-204-2005
1
7
20
26
X11
*) Filler plugs must be used on empty cavities to reach waterproofness
As seen from cable entry side
MIC1100S
09JAN2017
6/7
Mounting and Housing Dimensions
MIC1100S is fixed to mounting panel or flat surface with four M5
screws.
The preferred mounting position is connectors pointing downwards.
If the unit is mounted connectors pointing to side then it is vital to
leave some loose cable in a downward cue to prevent moisture
40
65 145
40
187
195
35
12
26
34.1
Note! Extra care should be paid on grounding of MIC1100S. The
lower right mounting hole is prepared for this purpose. It is
recommended to use ring tongue and joint compound to minimize
transient resistance.
Exertus reserves the rights to change product details without prior