Track system - Nordic Light

Track system
Track system
Track system
To get you right back on track and based on our customers’ feedback,
we have developed the NL Power Track System which will work with
our track lights to ensure compatibility with both previous and future
systems.
44
45
Track system
NLP 3-Circuit track system, standard
Track system
NLP 3-Circuit track system, standard
Technical Specification
Track
35
047-25
1 000 mm
047-258
2 390 mm
black or grey. Metal accessories also in white, black, or grey.
047-358
1 610 mm
047-27
3 000 mm
047-26
2 000 mm
047-28
4 000 mm
Tracks supplied in papercover. Copper-leads nickle-plated for
maximum protection against oxidization of leads. Knockout holes
35
NLP 3-Circuit track system. Termoplastic connectors in white,
L2
L1
L3
N
in track for direct to surface installation or via different ceiling
brackets. Appovedby SEMKO with CB-certificate.
General info.
Standard colors, -XX
Protection IP20
10 White, RAL 9010
16 A /400 V
20 Black, Sample plates available
Parts marked with * are feedable.
30 Grey, Sample plates available
132
047-11 End Cover
047-201 X Connector
132
047-203/047-303 T-Connector, Right*/Reverse*
86
047-206 End feed, Left*
84
047-209 Mini-Connector
132
84
047-204/047-304 L-Connector*/Reverse*
86
047-207 End feed, Right*
255
047-255 Flexible Connector
047-202/047-302 T-Connector, Left*/Reverse*
132
047-205 Middle Connector*
60-300°
047-264 Flex 60 Connector*
Track system
Track system
NLP 3-Circuit track system, recessed
NLP 3-Circuit track system, standard
Suspension Parts
Acoustic ceiling Parts
37
Track
Suspending a track can be done in two
These parts are used for installing the
35
047-39
1 000 mm
047-268
2 390 mm
ways with wire or rod.
track system into a architect ceiling.
047-368
1 610 mm
047-37
3 000 mm
047-38
2 000 mm
047-36
4 000 mm
Others
ø 26
110
110
41
L2
L1
L3
N
For vertical
load only
Max 40N
56
047-93 Reinforcement plate
047-128 R.P. ceiling profiles
110
41
047-76 Track clip
047-181 R.P. for Wire suspension
Protection IP20
10 White, RAL 9010
16 A /400 V
20 Black, Sample plates available
Parts marked with * are feedable.
30 Grey, Sample plates available
86
84
M6
17026 Threaded extension joint
047-11 End Cover
132
110
Standard colors, -XX
047-210 Suspension hook
50
047-121 R.P. recessed ceiling profiles
General info.
047-246 End feed, Right*
132
047-247/047-347 L-Connector*/Reverse*
13
2
41
047-19 Track clip ceiling profiles
047-286 Track suspension kit 6 000 mm
047-248/047-348 T-Connector, Left*/Reverse*
132
41
047-249/047-349 T-Connector, Right*/Reverse*
84
047-250 X-Connector
86
400
047-180 Track clip wire/rod
047-100 Track clip recessed ceiling profiles
047-283 Rod to fixate track
047-251 Middle Connector*
047-209 Mini-Connector
047-245 End feed, Left*
Track system
Track system
NLP 3-Circuit track system, good to know
Fixing knob
NLP 3-Circuit track system, good to know
3-Circuit Adapter. New version, rotatable 360°
Acoustic ceiling parts
The adapter is factory installed on the track fixtures. It is used to
These parts are used for installing the track system into a
connect the fixture to the NLP 3-circuit track system. The adapter
acoustic ceiling.There are two main types of acoustic ceilings,
also suits the majority of other 3-circuit track systems. Check with
one with recessed profile (1) and one non recessed (2), choose
Nordic Light. Track adapter is not sold separately.
mounting accessories according to ceiling type.
Installation:
1. Push the adapter into the track
2. Turn the fixing knob clockwise
Circuit selector
047-100
047-19
047-121
047-128
3. Select the desired phase on the circuit selector switch.
To remove the adapter from the track reverse the installation steps.
Ratings:
3 A, 220-240 V
IP 20
Max load: 50 N
Monopoint
The monopoint is used for installing a track light without a track.
The monopoint can be used in combination with the 3-Circuit
adapter.
27009
Monopoint, White
27010
Monopoint, Black
27011
Monopoint, Grey
047-320-10
Recessed holder, White
047-320-20
Recessed holder, Black
047-320-30
Recessed holder, Grey
Ratings:
3 A, 220-240 V
Ceiling tile
Profile
Load and fastening
1 000
Maximum distance allowed between each fastening point
is 2 m. The maximum load on the track is 10 kg.
20 N
20 N
20 N
20 N
20 N
IP 20
The tracks have knockout holes on the top side. These can be
Max load: 50 N
used for direct mounting into the ceiling with screws.
A
Suspension Parts
B
4
B
11
Suspending a track can be done in two ways with wire or rod. Use
047-180 or 047-181 for this type of suspension.
Wire: Thread the wire through the hole in the track clip and band it
back up through the wire lock. Secure the wire with the screws.
M6 Rod
Wire
Rod to fixate track
Screw
D
C
C
Rod: Thread the rod into the 047-181, the rod should have M6
threads. Screw: 047-76 or 047-93 can be used to fasten the track
A (mm)
B (mm)
C (mm)
D (mm)
directly into the framework with a screw.
4 000
152
1 195
1 603
To stabilize track on wire from tilting, use rod for wire suspension
2 390
152
1 195
-
track system to fixate the track 047-283.
1 610
152
-
-
Wire suspension type MaseTek to suspend
fixed loads such as track systems.
For 1 m track the maximum load is thus 10 kg.
Track system
Track system
NLP 3-Circuit track system, good to know
NLP 3-Circuit track system, examples
To change the L connector neutral side.
1. At first the connector has the neutral on the inside or outside
To change to the other side unscrew the two screws and
remove the cover.
2. Turn one the connecting sides 180 degrees and assemble the
cover. Now the connector is reverse.
T Connectors can also be changed in the same manner.
General comments on planning track systems.
The track system seen from above.
047-204
047-202
047-204
1. Never supply the power to the track at several locations.
2. Make sure that the track is straight both horizontal and vertical
Straight track, suspended
Articles
047-28
Track 4 000 mm
047-206
End feed
047-209
Mini connector
047-11
End Cover
047-273
Track suspension
047-181
RF plate for wire/rod
047-180
Track clip for wire/rod
Qty
2
1
1
1
7
1
6
Straight track, Acoustic ceiling
Articles
047-28
Track 4 000 mm
047-206
End feed
047-209
Mini connector
047-11
End Cover
047-128
RF plate ceiling profiles
047-180
Track clip ceiling profiles
Qty
2
1
1
1
1
6
Straight track, Recessed
Articles
047-36
Track 4 000 mm
047-245
End feed
047-209
Mini connector
047-11
End Cover
Qty
2
1
1
1
before powering on.
The red line indicates the neutral position.
047-204
047-303
047-204
047-304
047-302
047-304
Track casing
047-500
Track 2 390 mm
Long track casing used for covering of the Nordic Light standard tracks.
047-203
1. Use the wire suspension kits enclosed. Remove the end cover from
the track casing. Slide in the suspensions from the end of the Track
casing.
047-304
047-264
047-264
1
2
3
2. Use 3 suspension points per Track section (2 390 mm) Important:
The maximum load on each suspension is 20 kg. Do not exceed
this load at any time.
3. The track casing is only for use with Nordic Light 3 circuit power
track Type 047-***. Slide the power track into the Track casing from
the end of the track casing. ATTENTION: The power track and the
track casing are asymmetric. Check that the holes in the power track
and the screw tower channel in the track casing is located in line
with each other. If not, turn the power track the opposite way.
D=4.0-4.2 mm
047-264
L=14-16 mm
047-304
4
4. Screw the power track to the Track casing using one screw in every
knock out hole in top of the power track. Use only screw of type M4
or ISO 7050, with Diameter 4.0-4.2 mm and the length 14-16 mm.
Download PDF