Keysight U7232D DisplayPort Electrical Performance Validation and

Keysight U7232D
DisplayPort Electrical Performance Validation
and Compliance Software
For Infiniium Series Oscilloscopes
Data Sheet
02 | Keysight | U7232D DisplayPort Electrical Performance Validation and Compliance Software - Data Sheet
DisplayPort Compliance Software Helps You Do The Right Job Faster
Verify and debug your
DisplayPort designs more easily
Keysight Technologies, Inc. DisplayPort
Electrical Performance Validation and
Compliance software for Infiniium Series
oscilloscopes (see Table 2) provides you
with a fast and easy way to verify and
debug your DisplayPort interface designs
for sink and source ICs, motherboard
systems, computers and graphics cards
and now supports the DisplayPort 1.3
specification. The DisplayPort electrical
test software is designed for use in
DisplayPort Authorized Compliance
Test Houses, so you can confidently
use it to execute DisplayPort electrical
checklist tests as well as employ it as a
characterization tool.
To introduce a DisplayPort product to the
market, your product must successfully
pass compliance testing based on the
DisplayPort specification at an approved
DisplayPort test center or through a self
certification regimen defined by VESA 1
in cooperation with your company. Either
way, you will want to use the DisplayPort
Electrical Performance Validation and
Compliance software to troubleshoot, if
necessary, and then to validate the design
by performing the tests before the final
compliance test run.
Features
The DisplayPort electrical test software
is a full-featured package to simplify the
validation process of DisplayPort designs:
–– Full Physical Layer Testing High
speed Lanes
–– Full physical layer testing of AUX
channels
–– Support of 1.2 and 1.3 CTS versions
–– Test Status tracking
–– Support of MyDP/SlimPort
–– Measurement process configurability
–– Support of DualMode, or DP++
–– Automated scope measurement
setup
–– Test results reports with pass/fail
margin analysis
–– Automation control through AUX
Channel Controller
–– Optional switch control
With the DisplayPort electrical test
software, you can use the same
oscilloscope you use for everyday
debugging to perform automated testing
and margin analysis based on the
DisplayPort-specified test checklist.
Save time
The DisplayPort Electrical Performance
Validation and Compliance software
saves you time by setting the stage
for automatic execution of DisplayPort
electrical tests. Part of the difficulty of
performing electrical tests for DisplayPort
is connecting the oscilloscope to the
target device, configuring the instrument
for measurements, executing the test
procedures, defining the capabilities of
the device under test, and then analyzing
the measured results by comparing them
to limits published in the specification.
The DisplayPort electrical test software
does almost all of this work for you. In
addition, if you discover a problem with
your device, debug tools are available to
aid in root-cause analysis.
The DisplayPort software offers the
electrical tests for the source as well as
important tests for cable and calibration
for receiver tolerance testing. The
software automatically configures
the oscilloscope for each test, and it
provides an informative results report
that includes margin analysis indicating
how close your product is to passing or
failing that specification. Clock recovery
of each lane is accomplished according
to the standard by the oscilloscope
using proprietary software techniques.
See Table 1 for a complete list of the
measurements made by the DisplayPort
electrical test software.
Easy test definition
The DisplayPort Electrical Performance
Validation and Compliance software
extends the ease-of-use advantages of
Keysight’s Infiniium Series oscilloscopes
to testing DisplayPort designs. The
Keysight automated test engine walks
you quickly through the steps required to
define the device under test, to select the
tests, set up the tests, perform the tests,
and view the test results. You can pick
high-level test parameters to suit your
test process objectives, and then you can
proceed to select a category of tests all
at once, or specify individual tests. The
user interface is oriented to minimize
reconnections, which saves you time and
minimizes potential for operator error.
You can save tests and configurations
as project files and recall them later for
quick testing and review of previous test
results. Straightforward menus let you
perform tests with a minimum of mouse
clicks.
Further test process control is also
provided through the automation tab
of graphical user interface. This tab
allows the user to tailor scripts to control
external equipment such as power
supplies and temperature control units, or
to provide a different test flow.
1. Video Electronics Standards Association
(www.vesa.org)
2. SlimPort is a trademarked implementation of
MyDP by Analogix
03 | Keysight | U7232D DisplayPort Electrical Performance Validation and Compliance Software - Data Sheet
Test Environment Setup and Test Selection
The DisplayPort Electrical Performance
Validation and Compliance software now
allows you to define the DUT capability
and select test environment variables to
better suit your testing goals for speed
and cost. The setup process begins with
the Setup entry screen (shown in
Figure 1). This screen enables selection
of the DisplayPort Compliance test
specification (for instance 1.2b or 1.3 as
shown in Figure 1) and test groupings for
hi-speed video lane testing (Physical Layer
Tests), AUX Channel and whole device
characteristics (AUX PHY and Inrush
Tests), or HDMI over the DisplayPort
interface (DualMode tests). This screen
will also let you choose between exposing
just normative (mandatory) tests or all
tests: normative and informative. The
bottom portion of the environment Set Up
tab is dedicated to automation through
the AUX test mode. After making the
appropriate selections for you testing, the
setup continues with DUT characteristics
entry and connection specifics when the
Test Setup button is selected.
The Test Setup button presents a
series of screens that allow the user
to enter the key test and environment
information because there is a wide
range of test connections and optional
performance allowed for in the DisplayPort
specification.
Figure 1. DisplayPort Test Environment Setup.
Some of this test process information is briefly described below.
–– Device ID: Enter the device name and other pertinent information
–– Operator ID: For compliance test houses to identify the operator for QA process.
–– Project ID: For compliance test houses that identify projects by number this enables
the report to carry a key identification number to a contract.
–– Device type: Allows you to select between cable test, sink test and source test suite.
The most common selection is source testing.
–– Test type: Define whether tests will be single ended or differential. See Figure 2.
–– DUT definition: Select the capabilities of the DUT you wish to test. See Figure 3
–– Test fixture selection: Select the test fixture used. See Figure 4.
–– Connection type: Single-ended vs. differential connection: Choose between using
two channels of the scope to make a differential measurement using an ‘A minus B’
technique or by using differential probe on each scope channel for each lane, see
Figure 4.
–– Number of channels: You may choose to test 1, 2, or 4 channel connection. (Note:
Differential connection allows full lane selection, while single-ended can only
support testing 1 or 2 lanes). See Figure 4.
–– Oscilloscope connection: This screen allows you to assign oscilloscope channels and
device lanes to test. See Figure 5.
04 | Keysight | U7232D DisplayPort Electrical Performance Validation and Compliance Software - Data Sheet
Test Environment Setup and Test Selection (Continued)
The first setup screen is shown in Figure
2 with the Start Project screen. This is
where the project information and device
specifics such as Test Device, and Test
Type are entered. The Test Type refers
to whether the tests to be selected from
a subsequent menu will be single ended
tests only, differential tests only, or both
single-ended and differential tests.
A new capability to the DP EPV&V
software is to define data pattern;
selections are standard DP pattern and
arbitrary data pattern.
Figure 2. Start Project screen to enter standard test data and select Test Device Type and Test
Type. Shown is Test Type = Both to support single-ended and differential tests.
Device definition
Critical information to guide the test
process will be the device capability
information. This is information about
the test device such as the valid levels,
pre-emphasis settings, number of lanes,
bit rates and whether spread spectrum
clocking is enabled or not. These
capabilities are identified in the DUT
Definition screen in Figure 3.
Figure 3. DisplayPort EPVC software DUT Definition Entry in Setup.
05 | Keysight | U7232D DisplayPort Electrical Performance Validation and Compliance Software - Data Sheet
Test Connection Setup
Upon completion of the device definition,
the Test Connection Setup screen is
presented. This screen enables entry of
parameters that affect the connection of
the device to the oscilloscope. Specifically,
the fixture, the type of connection and
number of lanes connected. The fixture
selection enables not only Keysight
fixtures, but any of the current fixtures
provided by various fixture vendors as well.
While the de-embed files are available
for fixtures, the other fixtures will have
de-embed files as they are made available.
The Connection Type relates to how the
signal gets to the scope channel. If by
differential probe, then a probe amplifier
is assumed (such as the 1169A or N2800A)
and the operator will then have the
choice of using 1, 2, or 4 channels of test
(depending on whether the appropriate
number of lanes has been selected). If the
Connection Type is selected is singleended then each differential lane of the
test device will have two connections to
the scope. By default these are routed to
channels 1 and 3, or 2 and 4. This means
only two maximum lanes may be tested
this way at a time. Note: if the Test Type
selection in the Start Project screen
was ‘Both’ or ‘Single-Ended’, then the
Connection Type will default to ‘Single
ended’ and will be grayed out. The number
of channels allowed will always be aware
of the upstream selections so will limit the
number of channels based those inputs.
The final screen in the Test Setup loop is
the Channel Assignment Setup (shown in
Figure 5). It will portray the connection
expected in number of channels and type
of connection requested. It is editable and
if there are channel assignment conflicts,
the user is alerted to the fact.
Figure 4. DisplayPort EPVC software Test Connection Setup Screen.
06 | Keysight | U7232D DisplayPort Electrical Performance Validation and Compliance Software - Data Sheet
Test Selection
After defining the test environment
through the test setup loop, you are
presented with only those tests that are
appropriate for the environment chosen.
For instance, if spread spectrum clocking
(SSC) is not enabled, then no SSC tests
will appear. This is the case for the
optional settings of pre-emphasis and
levels as well. If your device definition
is one lane only, or your defined device
connection is one lane (one differential
probe or two single-ended connections)
then no inter-pair skew tests will appear
in the test suite. This dynamic filtering
simplifies your job by ensuring you attempt
to test only what is possible for the DUT
and the connection model you have
chosen.
The DP 1.3 test suite is shown in the Test
Selection screen is shown in Figure 6. It is
partitioned in groups of tests as a function
of the pattern that is required to test. HBR
(2.7 Gb/s) and RBR (1.62 Gb/s) bit rates
require PRBS7 and D10.2 patterns while
HBR2 (5.4 Gb/s) require special patterns
such as the HBR2 compliance test pattern
that has a repetition length of 2520 bits
(referred to as ‘CP2520’ or ‘HBR2CPAT’).
Tests may be selected independently and
any number of tests may be selected for a
given run. If more than one lane is possible
to run (as determined by the selections
in Setup) then test selection by lane is
also possible. If different connections
or conditions of test are required from
one test to another, a splash screen is
presented to the user indicating the
required change. When automation mode
is used with the AUX Channel Controller,
the device is changed automatically and
there is no need for the splash screens.
Figure 5. Channel Assignment Setup: Lane and oscilloscope assignment: Two Lane Single-ended
Connection using all four scope channels.
Figure 6. Lists the tests that are selectable and their status. Status bubbles indicate successful
completion, failure, or incompletion.
07 | Keysight | U7232D DisplayPort Electrical Performance Validation and Compliance Software - Data Sheet
Configurability and Guided Connections
The DisplayPort Electrical Performance
Validation and Compliance software
provides flexibility in your test setup. It
guides you to make connection changes
with hookup diagrams when the tests you
select require it. For test parameters such
as bandwidth, you can select appropriate
values. For more critical parameters,
such as mask scaling option or number of
edges for analysis, default values are tied
to the compliance standard; these values
can only be altered in the debug screen.
In Figure 7 you can see the selection
for various eye mask test functions. The
default for compliance mode is “Fixed”
which places the mask in the center of
the eye per the DisplayPort Compliance
test specification (shown is ‘Find Margin,’
which will find the range of passing
conditions).
Note: For HBR2 the eye diagram testing
is different from RBR and HBR as it
comprehends 10 –9 BER limits; so the
‘Find Margin’ capability is not available.
For HBR3, the testpoint is TP3EQ with
the equalizer being a combination
of CTLE and DFE. Because the DFE is
computationally complex, a standard mask
is used.
Figure 7. The Configure Tab enables changing measurement parameters in the ‘Debug’ mode to
support characterization and debug activities.
After you configure the test to meet
your needs, the DisplayPort EPV&C
software user interface displays the
connection screen, which is specific to
the configuration data you have selected.
Figure 8 illustrates the typical connection
guidance provided for a one channel “A
minus B” single-ended connection model
for a one lane test setup.
Figure 8. The final step before test is to illustrate the anticipated connection for the test.
08 | Keysight | U7232D DisplayPort Electrical Performance Validation and Compliance Software - Data Sheet
Margin Analysis
In addition to providing you with
measurement results, the DisplayPort
Electrical Performance Validation and
Compliance software provides a report
format that shows you not only where your
product passes or fails, but also reports
how close you are to the limits specified for
a particular test assertion. You select the
margin test report parameter, which means
you can specify the level at which warnings
are issued to alert you to the electrical
tests where your product is operating
close to the official test limit defined by the
DisplayPort compliance test specification
for a given test assertion.
Margin is calculated:
Single-sided specification:
Margin = (ValueSpecification – Valueactual)/ValueSpecification
Double-sided specification:
Margin = lowest of: (ValueSpecification_High – Valueactual)/RangeSpecification
and
(ValueSpecification_Low – Valueactual)/RangeSpecification
Eye margin: Another method of evaluating
the eye is provided by sweeping the eye
horizontally with the specified mask and
determining the last locations on the left
and right portions of the interior eye where
there are no violations in the mask. The
distance from the center mask location is a
measure of design margin and is reported
as eye margin if that eye mask mode is
chosen in the configuration screen (Eye
Diagram Mask Movement: Find Margin—
see Figure 7 for example).
AUX channel and Dual Mode
testing support
The DisplayPort EPV&C software also
supports Dual Mode (DP++) testing for
devices that are to interoperate with HDMI
displays. Eye diagram and jitter tests have
been ported from the HDMI software
application, which is a preferred application
in test labs around the world.
AUX channel testing is a different test suite
selectable in the Setup screen. The tests
available are shown at the bottom of
Table 1.
Dual Mode and the AUX channel test suite
are selected in the Setup screen shown in
Figure 1.
Figure 9. The DisplayPort EPVC test software results report documents your test, indicates the
pass/fail status, the test specification range, the measured values, and the margin.
09 | Keysight | U7232D DisplayPort Electrical Performance Validation and Compliance Software - Data Sheet
Thorough Performance Reporting
The DisplayPort Electrical Performance
Validation and Compliance software
generates thorough reports that not only
capture the performance and status
of the device under test, but also the
screen shots of your most significant
measurements for your perusal and
evaluation. The first page of the report
lists equipment and configuration details
required in standard quality assurance
programs. It also provides a hot-linked
results table that will quickly get you
to the measurement report section of
interest.
Figure 10. The DisplayPort compliance software generates a summary report where you can see
the total test results for your device quickly and clearly. Additional details are available for each
test, including the test limits, test description, and test results, including waveforms, if appropriate.
All are hot linked to more detailed results further in report. In addition, the margin of the result is
indicated to provide further insight.
Figure 11. Summary report detail: The DisplayPort software’s summary report provides screen
shots of all the measurements that have been performed. In this figure you can see the data-eye.
Observe the clear status and description at the top and the measurement data just above the eye.
10 | Keysight | U7232D DisplayPort Electrical Performance Validation and Compliance Software - Data Sheet
Test Status Tracking
The DisplayPort Electrical Performance
Validation and Compliance software can
keep track of the status in a test plan
and is visually viewable in the Test Run
menu (Figures 12 and 13). In addition, you
can choose to resume testing the device
and the software will continue where it
stopped the time before.
Figure 12. Show Test Status: Test Status selected in the Run Tests menu.
Figure 13. Test Status tracking: When all tests are complete there are no entries below ‘Remaining
Permutations Summary’.
11 | Keysight | U7232D DisplayPort Electrical Performance Validation and Compliance Software - Data Sheet
Extensibility
You may add additional custom tests or
steps to your application using the User
Defined Application (UDA) development
tool (www.keysight.com/find/uda). Use
UDA to develop functional “Add-Ins” that
you can plug into your application.
Add-ins may be designed as:
–– Complete custom tests (with
configuration variables and
connection prompts)
–– Any custom steps such as pre or
post processing scripts, external
instrument control and your own
device control
Figure 14. Importing a UDA Add-In into your test application.
Figure 15. UDA Add-In tests and utilities in your test application.
12 | Keysight | U7232D DisplayPort Electrical Performance Validation and Compliance Software - Data Sheet
Automation
You can completely automate
execution of your application’s tests
and Add-Ins from a separate PC using
the included Remote Interface feature
(download free toolkit from www.keysight.
com/find/scope-apps-sw). You can
even create and execute automation
scripts right inside the application using a
convenient built-in client.
The commands required for each task may
be created using a command wizard or
from “remote hints” accessible throughout
the user interface.
Using automation, you can accelerate
complex testing scenarios and even
automate manual tasks such as:
–– Opening projects, executing tests and
saving results
–– Executing tests repeatedly while
changing configurations
–– Sending commands to external
instruments
–– Executing tests out of order
Figure 16. Remote Programming script in the Automation tab.
Compliance app + Automation engine
UDA add-in
- Custom test/Steps
- Post processing
Combine the power of built-in automation
and extensibility to transform your
application into a complete test suite
executive:
–– Interact with your device controller
to place it into desired states or test
modes before test execution
–– Configure additional instruments used
in your test suite such as a pattern
generator and probe switch matrix.
–– Export data generated by your tests
and post-process it using your favorite
environment, such as MATLAB,
Python, LabVIEW, C, C++, Visual Basic
etc.
–– Sequence or repeat the tests and
“Add-In” custom steps execution in
any order for complete test coverage
of the test plan.
C++ Script
LabVIEW
UDA add-in
- DUT control
- Instrument control
Pattern
generator
Custom tests
Matlab processing
Results
DUT or external
instrument control
Switch
matrix
Live signals
DUT
Custom tests/Steps
or post processing
Figure 17. Combine the power of built-in automation and extensibility to transform your application
into a complete test suite executive.
13 | Keysight | U7232D DisplayPort Electrical Performance Validation and Compliance Software - Data Sheet
Switch Matrix
The Keysight switch matrix software
option for the compliance application,
used together with switch matrix
hardware, enables fully automated testing
for multi-lane digital bus interfaces. The
benefits of this automated switching
solution include:
–– Eliminate reconnections, which saves
time and reduces errors through
automating test setup for each lane of
a multi-lane bus.
–– Maintain accuracy with the use of
unique PrecisionProbe or InfiniiSim
features to compensate for switch
path losses and skew.
–– Customize testing by using remote
programming interface and the
user-defined application tool for
device control, instrument control and
test customization.
Figure 18. Automated testing for multi-lane digital bus interface through switching solution.
More information of the switching solution
and configuration, visit
www.keysight.com/find/switching and
the Keysight application note with the
publication number 5991-2375EN.
Figure 19. Switch matrix software feature enabled in the compliance application.
14 | Keysight | U7232D DisplayPort Electrical Performance Validation and Compliance Software - Data Sheet
DisplayPort Test Point Adapters
DisplayPort has added other connector
forms in addition to the original standard
connector. These include the Mini-DP
connector (mDP), the eDP connector
(in 20, 30, 40, and 50 pin versions), and
most recently the USB Type-C connector.
The DisplayPort Electrical Performance
Validation and Compliance software
allows you to choose the test point
adapter you want and if the file is available
from the vendor, it allows you to
de-embed it as well.
N7015A Type-C connector Test Point Adapter
DisplayPort AUX channel control
The DisplayPort specification allows
for automated device control through
manipulation of the DPCD (DisplayPort
Configuration Data) registers. Those
registers are most conveniently controlled
by an AUX channel controller. The choice
of AUX channel controllers is shown in the
ordering information section.
Figure 20. The Keysight N7015A USB Type-C Test Point Adapter Fixture.
Measurement connections
To use the DisplayPort Electrical Performance Validation and Compliance software
with any test point adaptor you will need the cables and other sundry components. The
Keysight N7015A USB Type-C TPA fixture or Wilder Technologies TPAs may require extra
cables to get to scope channels when connected single-ended. Order from matched
cable sets in the accessories table below. Use of differential probe amplifiers and
appropriate SMA probe heads is optional. However, if you want connection simplicity,
consider these probes for one-time setup and complete characterization for all
differential measurements.
You can minimize reconnect time by using four InfiniiMax probes to measure all four Main
Link differential data lanes (Lane0, Lane1, Lane2, Lane3) without having to reposition
or reconnect probes. To use this capability, select Connection Type: Differential Probe,
Number of Channels: Four Channels in the Setup screen.
If you are not using a Test point adaptor but probing signals with solder in differential
probes or browsers then you will need to select the appropriate probe head for the task
and the probe amplifier system you are using. For instance, if the high speed signals are
only accessible through a terminated 50-Ω transmission line (for testing silicon devices
for example), you will need to use solder-in differential probe heads for differential
probing and select these in the scope channel setup menu.
15 | Keysight | U7232D DisplayPort Electrical Performance Validation and Compliance Software - Data Sheet
Tests Performed
The DisplayPort Electrical Performance
Validation and Compliance software
performs all the anticipated required
tests for the DisplayPort Compliance Test
Specification 1.3 (CTS 1.3).
Table 1. DisplayPort electrical tests performed by the DisplayPort software
Assertion no. Test description
Compliance Included with DP
status
EPVC software
Section 3
Source tests
Test ID 3.1
Data Eye Diagram
Normative
Yes
Test ID 3.2
Non Pre-Emphasis Level Verification
Normative
Yes
Test ID 3.3
Pre-Emphasis Level Verification
Normative
Yes
Test ID 3.4
Inter-Pair Skew
Normative
Yes
Test ID 3.5
Intra-Pair Skew
Informative Yes
Test ID 3.6
Differential Transition Time
Omitted 1
Yes
Test ID 3.7
Single-Ended Rise and Fall Mismatch
Omitted 1
Yes
Test ID 3.10
AC Common Mode Noise
Informative Yes
Test ID 3.11
Non-ISI Jitter Measurements
Normative
Yes
Test ID 3.12
Total Jitter Measurements
Normative
Yes
Test ID 3.14
Main Link Frequency Compliance
Normative
Yes
Test ID 3.15
Spread Spectrum Modulation Frequency
Normative
Yes
Test ID 3.16
Spread Spectrum Modulation Deviation
Normative
Yes
Test ID 3.17
Spread Spectrum dF/dt
Informative No
Test ID 3.18
Dual Mode: TMDS Clock
Normative
Yes
Test ID 3.19
Dual Mode: TMDS Eye Diagram Testing
Normative
Yes
Section 8
Common tests (refer to CTS 1.2b)
Test ID 8.1
AUX Manchester Channel Eye
Normative
Yes
Test ID 8.2
AUX Manchester Channel SensitivityTest
Normative
Yes
Test ID 8.3
Aux Channel DC Test: Aux - Termination
Normative 2 No
Test ID 8.4
Aux Channel DC Test: Aux + Termination
Normative 2 No
Test ID 8.5
Inrush/Outrush Tests
Normative
Yes
Test ID 8.6
DP_PWR DC Levels
Normative
No
Test ID 8.7
DP_PWR Current
Normative
No
MyDP Tests
Tests identified in Section 7.1 and 4.3 of MyDP CTS v1.0
Recommended
Oscilloscopes
Table 2. Recommended oscilloscopes
The DisplayPort Electrical Performance
Validation and Compliance software is
compatible with all Infiniium real-time
oscilloscopes with latest software revision.
For oscilloscopes with earlier software
revisions, free upgrade software is
available at http://www.keysight.com/
find/infiniium_software.
Minimum bandwidth
Minimum channels
Oscilloscope models
16 GHz
4 channels
Infiniium 90000A, 90000 X-, V-Series, and Z-Series
3
1. These tests originally included for DisplayPort CTS 1.1, omitted since CTS 1.2 and provided
informationally.
2. Tests 8.3 and 8.4 are easily accomplished on a source device with use of an AUX signal breakout
device such as the Wilder TPA-DP-A with external resistors, a 3.3 volt power supply and a voltmeter.
3. 13 GHz is usable for RBR, HBR and HBR2.
Note that the DisplayPort test software can make other measurements not included here, such as receiver eye
measurements and equalized eye measurements as well most of the omitted CTS 1.1measurements.
16 | Keysight | U7232D DisplayPort Electrical Performance Validation and Compliance Software - Data Sheet
Ordering Information
Application
License type
Infiniium
V-Series and Z-series
Infiniium 90000 Series
Infiniium 90000 X-Series
DisplayPort 1.3
EPV&C software
(DisplayPort 1.2 and
1.3)
Fixed
DSOV000-092,
DSOZ000-092
U7232D -1FP
U7232D -1TP
DSO90000A-057
DSOX90000-092
U7232D -1NL 2 or U7232D -1FP 1
U7232D -1TP 1, 2
DisplayPort 1.2
upgrade 3 to
DisplayPort 1.3
Fixed
DisplayPort 1.3
EPV&C software
(DisplayPort 1.2 only)
Fixed
Serial data analysis
software (included in
DSA model)
Fixed
U7232D -1NL 2 or U7232D -1FP 1
U7232D -1TP 1, 2
N5435A-093
N/A
N/A
N/A
N/A
DSO90000-045
U7232D -3NL 2 or U7232D -3FP 1
U7232D -3TP 1, 2
N5435A-041
DSO90000A-003
E2688A-1NL 2 or E2688A-1FP 1
E2688A-1TP 1, 2
N5435A-003
EZJIT Plus
(recommended)
Fixed
DSO90000A-004
N5400A-1NL 2 or N5400A-1FP 1
N5400A-1TP 1, 2
N5435A-001
DSO90000A-012
N5461A-1NL 2 or N5461A-1FP 1
N5461A-1TP 1, 2
N5435A-025
DSO90000A-014
N5465A-1NL 2 or N5465A-1FP 1
N5465A-1TP 1, 2
N5435A-027
DSO90000A-001
N2809A-1NL 2 or N2809A-1FP 1
N2809A-1TP 1, 2
N5435A-003
DSO90000A-714
DSOX90000-004
N5400A-1NL 2 or N5400A-1FP 1
N5400A-1TP 1, 2
U7232D -7NL 2 or U7232D -7FP 1
U7232D -7TP 1, 2
N5435A-714
DSO90000A-009
N5414B-1N L 2 or N5414B-1FP 1
N5414B-1TP 1, 2
N5435A-004
U7232D -7NL 2 or U7232D -7FP 1
U7232D -7TP 1, 2
Floating
Floating
Floating
Floating
Floating
Equalization
(required)
Fixed
Floating
InfiniiSim Advanced
(required)
Fixed
Floating
PrecisionProbe
(optional)
Fixed
Floating
DisplayPort switch
matrix support
(optional)
Fixed
Floating
InfiniiScan+
(optional)
Fixed
Floating
Factory-installed
User-installed
Transportable
Server-based
Factory-installed
User-installed
Transportable
Server-based
Factory-installed
User-installed
Transportable
Server-based
Factory-installed
User-installed
Transportable
Server-based
Factory-installed
User-installed
Transportable
Server-based
Factory-installed
User-installed
Transportable
Server-based
Factory-installed
User-installed
Transportable
Server-based
Factory-installed
User-installed
Transportable
Server-based
Factory-installed
User-installed
Transportable
Server-based
Factory-installed
User-installed
Transportable
Server-based
N/A
U7232D -2FP
N/A
U7232D -3FP
U7232D -3FP
U7232D -3TP
E2688A-1FP
E2688A-1FP
E2688A-1TP
N5400A-1FP
N5400-1FP
N5400A-1TP
N5461A-1FP
N5461A-1FP
N5461A-1TP
N5465A-1FP
N5465A-1FP
N5465A-1TP
N2809A-1FP
N2809A-1FP
N2809A-1TP
DSOV000-714,
DSOZ000-714
U7232D -7FP
U7232D -7TP
N5414B-1FP
N5414B-1FP
N5414B-1TP
N/A
U7232D -2FP
N/A
DSOX90000-045
U7232D -3NL 2 or U7232D -3FP 1
U7232D -3TP 1, 2
DSOX90000-003
E2688A-1NL 2 or E2688A-1FP 1
E2688A-1TP 1, 2
DSOX90000-012
N5461A-1NL 2 or N5461A-1FP 1
N5461A-1TP 1, 2
DSOX90000-014
N5465A-1NL 2 or N5465A-1FP 1
N5465A-1TP 1, 2
DSOX90000-001
N2809A-1NL 2 or N2809A-1FP 1
N2809A-1TP 1, 2
DSOX90000-714
DSOX90000-009
N5414B-1NL 2 or N5414B-1FP 1
N5414B-1TP 1, 2
1. Requires software 5.00 and above.
2. Software 4.30 or above requires Windows 7. N2753A Infiniium Windows XP to 7 OS upgrade kit (oscilloscope already has M890 motherboard). N2754A
Infiniium Windows XP to 7 OS and M890 motherboard upgrade kit (oscilloscope without M890 motherboard). Verify the M890 motherboard using the
procedure found in the Windows 7 upgrade kit data sheet with the publication number 5990-8569EN.
3. DP upgrades require SDA, InfiniiSim, and Equalization.
17 | Keysight | U7232D DisplayPort Electrical Performance Validation and Compliance Software - Data Sheet
Test point access adapters
For physical connection to a DisplayPort device to perform tests with the DisplayPort Compliance Test Software, order one or more of
the following:
Model number
N7015A or N7015A Option 016
BIT-mDP-PTF-0001
BIT-eDP-PTF-0001
BIT-DP-PTF-0003
BIT-DP-RTF-0003
BIT-DP-CONN-0001
Description
USB Type-C Test Point Adapter
Mini-DP Plug Test Point Access Adapter
eDP Plug Test Point Access Adapter
Standard DisplayPort Plug Test Point Access Adapter
Standard DisplayPort Receptacle Test Point Adapter. Used in Cable Test or Sink system
calibration
Connection Kit for Bitifeye Fixtures. Includes 2 matched sets of SMA-SMA 1 meter
cables and low frequency adaptor board.
Quantity
1
1
1
1
As needed
1
Fixtures with Prefix ‘BIT’ are procured through BitifEye Corporation (Note: TPAs available through Wilder Technologies and ICT Luxshare are also
recommended).
Connections often require matched cable sets and adapters. See accessory table below for these items.
18 | Keysight | U7232D DisplayPort Electrical Performance Validation and Compliance Software - Data Sheet
AUX channel controller
(optional)
To purchase AUX channel controller for
automated control of the device under test
with the DisplayPort software, order:
Measurement and test
accessories
To complete your test setup, Keysight
provides a wide range of cables, adapters,
terminations, etc. You may find these
useful in troubleshooting, calibrations, etc.
Related Literature
Model number
Unigraf DPR100
Description
AUX channel controller requires hardware and software license
Quantity
1
Note: DPR100 is available through Unigraf or its distributors - www.unigraf.fi
Model number
11667B
11636B
8493B
5061-5311
1250-1159
1250-1397
1250-1741
1250-1698
1250-1694
N1021-60003
1810-0118
33SMA-Q50-0-4
Description
Power splitter, DC to 26.5 GHz, 3.5-mm (f) connectors
Power divider, DC to 26.5 GHz, 3.5-mm (f) connectors
Coaxial attenuator (3, 6, 10, 20, or 30 dB), DC to 18-GHz, SMA connector
3.5-mm (f - f) adapter, DC to 26 GHz, recommended
SMA (m - m) adapter, DC to 18 GHz
Right-angle adapter, SMA (m - m)
Right-angle adapter, SMA (f - m)
SMA tee adapter (m, f, f), DC to 12.4 GHz
SMA (m) to SMA (f) adapter
Cable assembly, coaxial 2.92 mm (m-m) phased matched pair (5 ps), 1 m
SMA (m) 50 Ω termination
SMA push-on adaptors from S.M. Electronics (or equivalent)
Publication title
N5990A Test Automation Software Platform - Data Sheet
Infiniium 90000 Series Oscilloscopes - Data Sheet
Infiniium 90000 X-Series Oscilloscopes - Data Sheet
N5399C, N5399D HDMI Electrical Performance Validation and Compliance
Software - Data Sheet
Infiniium Z-Series Oscilloscopes - Data Sheet
Infiniium V-Series Oscilloscopes - Data Sheet
Publication number
5989-5483EN
5989-7819EN
5990-5271EN
5990-5299EN
5991-3868EN
5992-0425EN
For copies of this literature, contact your Keysight representative or visit
www.keysight.com/find/scope-apps
19 | Keysight | U7232D DisplayPort Electrical Performance Validation and Compliance Software - Data Sheet
Keysight Oscilloscopes
Multiple form factors from 20 MHz to > 90 GHz | Industry leading specs | Powerful applications
20 | Keysight | U7232D DisplayPort Electrical Performance Validation and Compliance Software - Data Sheet
www.axiestandard.org
AdvancedTCA® Extensions for Instrumentation and Test (AXIe) is an
open standard that extends the AdvancedTCA for general purpose and
semiconductor test. Keysight is a founding member of the AXIe consortium.
ATCA®, AdvancedTCA®, and the ATCA logo are registered US trademarks of
the PCI Industrial Computer Manufacturers Group.
www.lxistandard.org
LAN eXtensions for Instruments puts the power of Ethernet and the
Web inside your test systems. Keysight is a founding member of the LXI
consortium.
www.pxisa.org
PCI eXtensions for Instrumentation (PXI) modular instrumentation delivers a
rugged, PC-based high-performance measurement and automation system.
21 | Keysight | U7232D DisplayPort Electrical Performance Validation and Compliance Software - Data Sheet
From Hewlett-Packard through Agilent to Keysight
For more than 75 years, we‘ve been helping you unlock measurement insights. Our
unique combination of hardware, software and people can help you reach your next
breakthrough. Unlocking measurement insights since 1939.
1939
THE FUTURE
myKeysight
www.keysight.com/find/mykeysight
A personalized view into the information most relevant to you.
Three-Year Warranty
www.keysight.com/find/ThreeYearWarranty
Keysight’s committed to superior product quality and lower total cost of
ownership. Keysight is the only test and measurement company with a
three-year warranty standard on all instruments, worldwide. And, we provide
a one-year warranty on many accessories, calibration devices, systems and
custom products.
Keysight Assurance Plans
www.keysight.com/find/AssurancePlans
Up to ten years of protection and no budgetary surprises to ensure your
instruments are operating to specification, so you can rely on accurate
measurements.
Keysight Infoline
www.keysight.com/find/service
Keysight’s insight to best in class information management. Free access to
your Keysight equipment company reports and e-library.
Keysight Channel Partners
www.keysight.com/find/channelpartners
Get the best of both worlds: Keysight’s measurement expertise and product
breadth, combined with channel partner convenience.
www.keysight.com
www.keysight.com/find/U7232D
For more information on Keysight
Technologies’ products, applications or
services, please contact your local Keysight
office. The complete list is available at:
www.keysight.com/find/contactus
Americas
Canada
Brazil
Mexico
United States
(877) 894 4414
55 11 3351 7010
001 800 254 2440
(800) 829 4444
Asia Pacific
Australia
China
Hong Kong
India
Japan
Korea
Malaysia
Singapore
Taiwan
Other AP Countries
1 800 629 485
800 810 0189
800 938 693
1 800 11 2626
0120 (421) 345
080 769 0800
1 800 888 848
1 800 375 8100
0800 047 866
(65) 6375 8100
Europe & Middle East
Austria
Belgium
Finland
France
Germany
Ireland
Israel
Italy
Luxembourg
Netherlands
Russia
Spain
Sweden
Switzerland
United Kingdom
0800 001122
0800 58580
0800 523252
0805 980333
0800 6270999
1800 832700
1 809 343051
800 599100
+32 800 58580
0800 0233200
8800 5009286
800 000154
0200 882255
0800 805353
Opt. 1 (DE)
Opt. 2 (FR)
Opt. 3 (IT)
0800 0260637
For other unlisted countries:
www.keysight.com/find/contactus
(BP-01-01-16)
www.keysight.com/go/quality
Keysight Technologies, Inc.
DEKRA Certified ISO 9001:2008
Quality Management System
This information is subject to change without notice.
© Keysight Technologies, 2015 - 2016
Published in USA, February 4, 2016
5992-1051EN
www.keysight.com
Download PDF