RamSoft Teleradiography Reinstall

RamSoft Teleradiography Reinstall
The following instructions explain the Install / Re-Install and Configure the RamSoft
Application.
Uninstall .............................................................................................................................. 1 Install / Re-Install................................................................................................................ 2 RamSoft Configure ............................................................................................................. 3 Uninstall 1.
2.
Click on the MobilexUSA PowerReader icon or type https://telrad.mobilexusa.com to
open up the following Internet Explorer window:
Click on Uninstall All with the mouse and uninstall the Ramsoft PowerReader Program.
3.
At the prompt “Are you sure you want to uninstall all Power Reader Clients?” click on
OK to uninstall
4.
The web page will display the uninstall process
5.
When the web page returns to a login page, the program has been uninstalled Go to Step
2 of Install / Re-Install
1
Install / Re­Install 1.
2.
4.
5.
6.
7.
Open Internet Explorer and type https://telrad.mobilexusa.com.
Type your Username and Password to log back in to Ramsoft PowerReader. Click on
the Login button
3.
Upon entering a valid username and password the RamSoft AactiveX client will attempt
to install
a. You may be prompted to allow this function continue
i. Either by a window pop up
ii. Or by a drop down prompted located under the web site address
1. Right Click the Active X bar and go to install.
2. At the installation box click on “Install”
This will begin the installation of PowerReader which is displayed as two green progress
bars.
The program will load automatically upon completion.
The Local Set Up must be completed or confirmed.
2
RamSoft Configure 1.
From the RamSoft menu Click SETTINGS
2.
Then select LOCAL SETUP
3.
The Local Setup screen will appear.
a.
Film Digitizer
3
i. Rad Sites have to select “VIDAR” or “RADLINK” for the Film Digitizer
depending on the scanner type.
ii. All other users, leave settings as NONE
4.
Click on the PowerReader Tab
a. The Name Field shown below is unique to each computer as it is the name of the
computer which the program is being installed onto, this will not need to be changed.
b. If a prompt states that computer name already exists, please contact the MobilexUSA
helpdesk @ 800-821-9236 x4203
c. Reading Radiologist Installs
i. Make certain the Polling Interval is set to 60 seconds.
ii. Make cert
4
d. All other Installs
i. Make certain the Polling Interval is set to 1800 seconds
e. All Installs
i. Change the Max number of Objects to 10
5
5.
If this local setup screen does not appear, please be sure to confirm settings by clicking
Settings, and then Local Setup
6.
Verify Compression by clicking View and Compression:
a. Radiologist
i. UNCOMPRESSED or LOW compression
b. All Other Users
i. ULTRACOMPRESSED or HIGH
c. Click View, then Compression, then click the option