EnergyCell GH
V R L A B AT T E R Y F O R G R I D / H Y B R I D E N E R G Y S TO R A G E
Three Reasons to Choose the EnergyCell GH
from OutBack Power:
1 . P U R P O S E - B U I LT
• Batteries designed for residential or light-commercial grid-tied
battery backup renewable energy power demands
• Thin-plate pure lead AGM technology ensures long float life in
battery backup applications
• Wide operating temperature range
• 18-month shelf life at 25°C
2 . E A S Y - T O - I N S TA L L A N D M A I N TA I N
• VRLA-AGM technology means 99% gas recombination efficient,
no periodic watering of cells, no retorquing of terminal
connections, and no equalization charge under standard
operating conditions
• Modular space-saving design when installed with IBR rack
• IBR racking included with intercell connects and front access to
cell connections
OutBack EnergyCell GH Typical
System Integration:
• 4 year full replacement warranty
Power Flow
• OPTICS RE connectivity means real-time access to critical battery
performance data
PV Source
• Batteries and power electronics can be installed in the same area1
3 . S I N G L E - B R A N D S Y S T E M S O LU T I O N
Main Panel
FLEXpower TWO
• Optimized to work seamlessly with OutBack power
conversion equipment
• Ease of ordering with SystemEdge package configurations—
to learn more visit www.outbackpower.com
Grid
• Single point of contact for all technical system inquiries
• Quality and reliability from OutBack Power assures customers
receive the best technologies for renewable energy systems in
the market today
Generator
Load
Sub Panel
Energy Storage
OUTBACK POWER—MASTERS OF THE OFF-GRID. FIRST CHOICE FOR THE NEW GRID.
MAKE THE POWER
• FLEXpower Integrated Systems
• Inverter/Chargers & Charge Controllers
STORE THE ENERGY
MANAGE THE SYSTEM
• EnergyCell RE, GH, NC and OPzV Batteries
• Battery Enclosures and Racking
• OPTICS RE System Monitoring and Control
• MATE3 System Display and Communications
OutBack reserves the right to make changes to the products and information contained in this document without notice.
Copyright © 2017 OutBack Power. All Rights Reserved. OutBack is a registered trademark of The Alpha Group.
1
EnergyCell GH S P E C I F I C AT I O N S 05/2017
Models: EnergyCell 200GH
Cells Per Unit
Voltage Per Unit
Operating Temperature Range
(w/ temperature compensation)
Optimal Operating Temperature Range
Float Charging Voltage
Maximum Charge Current
Absorbed Voltage
Self Discharge
Temp Compensation Factor (Charging)
Terminal
Terminal Hardware Initial Torque
Weight (lb/kg)
Dimensions H x D x W (in/cm)
EnergyCell 220GH
6
6
12VDC
12VDC
-40 to 122°F (-40 to 50°C)
-40 to 122°F (-40 to 50°C)
68°F (20°C)
68°F (20°C)
13.62VDC / unit average at 77°F (25°C)
13.62VDC / unit average at 77°F (25°C)
106.2A
118.8A
14.4VDC / unit average at 77°F (25°C)
14.4VDC / unit average at 77°F (25°C)
Battery can be stored up to 18 months at 77°F (25°C) before a freshening charge is required. Batteries stored at temperatures greater than 77°F (25°C) will require recharge sooner than batteries stored
at lower temperatures.
±4mV per °C per cell (2V)
±4mV per °C per cell (2V)
Threaded copper alloy insert terminal to accept ¼”-20 UNC bolt
Threaded copper alloy insert terminal to accept ¼”-20 UNC bolt
M6 = 80in-lbs (9.0Nm)
M6 = 80in-lbs (9.0Nm)
116 / 53
132 / 60
11.1 x 22.1 x 4.9 / 28.2 x 56.1 x 12.4
12.4 x 22.1 x 4.9 / 31.5 x 56.1 x 12.4
12V Ampere Hour Capacity to 1.75 Volts Per Cell at 77°F (25°C)
Discharge in Hours:
1
3
4
5
8
12
20
24
100
EnergyCell 200GH
120
148.5
154.8
159
168.8
176.4
191
189.6
200
EnergyCell 220GH
133.5
166.2
173.2
178
188.8
198
214
216
220
Consult local and regional electrical code for proper installation of energy storage requirements.