Point System™ Management Modules Specifications CPSMM

point system™ chassis and ion specifications
Point System™ Management
Modules Specifications
Point System™ Management Modules
CPSMM-120
CPSMM-200
CPSMM-210
Single Slot Master
Management Module
Dual Slot Master
Management Module
Single Slot Expansion
Management Module
This device occupies a single slot in
the Point System chassis and it fully supports all
management features. The CPSMM-120 has a
DB-9 serial interface for the CLI (command line
interface) as well as a 10BASE-T RJ-45 interface for
network management. The CPSMM-120 should be
used when the Point System chassis is intended to
be used as a single device (when the user does not
intend to stack multiple Point System Chassis together).
The CPSMM-200 should be used
when the user intends to manage multiple stacked
chassis (up to 8 chassis per stack) via a single IP or
if the application requires an FCC/CISPR Class B
rating. This device occupies two slots in a Point
System chassis and will also fully support all management features. The CPSMM-200 has a
DB-9 serial interface as well as a 10BASE-T
interface similar to the CPSMM-120. However, it also
includes two (2) additional RJ-45 ports ("in" and
"out") to accommodate stacking of multiple Point
System Chassis’. The CPSMM-200 also differs from
the CPSMM-120 in that it is FCC/CISPR Class B
rated.
This device, used in conjunction with
the CPSMM-200 (or CPSMM-120 when inserted in
the same chassis) management module, allows the
user to manage up to eight Point System chassis together in a "virtual cabinet". This brings the total
number of cards managed by a single IP to 143. The
CPSMM-210 has two RJ-45 ports ("in" and "out")
used for stacking multiple Point System chassis. The
CPSMM-210 incorporates a self-healing bus so that
the failure of any one module will not effect
remaining modules in the stack. The CPSMM-210
should be used when the user has a requirement to
stack multiple chassis.
Specifications
Specifications
Specifications
Product Number
CPSMM-120
Single Slot Master Management
Module
Ports
DB-9 (x1), RJ-45 (x1)
LEDs
Power, Link, TX, RX
Storage Temp
-40 – 80° C
Operating Temp
0 – 50° C
Altitude
0 – 10,000ft.
Shipping Weight
1 lb. [0.45 kg]
Dimensions
Width: 0.86" [22 mm]
Depth: 5.0" [127 mm]
Height: 3.4" [86 mm]
Compliance
FCC & CISPR Class A; CE Mark
Warranty
Lifetime
Optional Accessories
(sold separately)
Null Modem Configuration Cable:
SC-NM-9F9F-06F
6 ft Cable
SC-NM-9F9F-10F
10 ft Cable
Product Number
CPSMM-200
Dual Slot Master Management Module
Ports
DB-9 (x1), RJ-45 (x3)
LEDs
Power, Link, TX, RX
Storage Temp
-40 – 80° C
Operating Temp
0 – 50° C
Altitude
0 – 10,000ft.
Shipping Weight
2 lbs. [0.90 kg]
Dimensions
Width: 2.0" [51 mm]
Depth: 5.0" [127 mm]
Height: 3.4" [86 mm]
Compliance
FCC & CISPR Class B; CE Mark
Warranty
Lifetime
Optional Accessories
(sold separately)
Null Modem Configuration Cable:
SC-NM-9F9F-06F
6 ft Cable
SC-NM-9F9F-10F
10 ft Cable
Product Number
CPSMM-210
Single Slot Expansion Management
Module: Used in conjunction with
CPSMM-120 or CPSMM-200
Ports
RJ-45 (x2)
LEDs
Power, Link
Storage Temp
-40 – 80° C
Operating Temp
0 – 50° C
Altitude
0 – 10,000ft.
Shipping Weight
1 lb. [0.45 kg]
Dimensions
Width: .086" [22 mm]
Depth: 5.0" [127 mm]
Height: 3.4" [86 mm]
Compliance
FCC & CISPR Class B; CE Mark
Warranty
Lifetime
Optional Accessories
(sold separately)
Null Modem Configuration Cable:
SC-NM-9F9F-06F
6 ft Cable
SC-NM-9F9F-10F
10 ft Cable
Transition Networks, Inc.
Worldwide Headquarters:
10900 Red Circle Drive
Minnetonka, MN 55343 USA
tel: 952.941.7600 / 800.526.9267
fax: 952.941.2322
info@transition.com
http://www.transition.com
©2010 Transition Networks, Inc.
All trade marks are the property of their respective owners.
Technical information is subject to change without notice.
User’s Guide
CPSMM-200 - Dual-Slot Master Management Module
CPSMM-210 - Single-Slot Expansion Management Module
CPSMM-200
Dual-Slot Master
CPSMM-210
Single-Slot Expansion
Transition Networks CPSMM-200 Dual-Slot Master Management Module enables
network management of a single PointSystem™ chassis (CPSMC0800-100,
CPSMC13xx-100, CPSMC18xx-xxx, and CPSMC19xx-100) and any installed media
converter slide-in-modules.
The CPSMM-200 includes Transition Networks CPSMM100 Firmware embedded
in the module, which can be accessed via the DB-9 serial port or the 10Base-T RJ45 Ethernet port.
In addition, the CPSMM-200 has two RJ-45 ports (“in” and “out”) to accommodate
stacking multiple PointSystem™ chassis. Multiple chassis can be “cascaded” in
this manner with a CPSMM-210 Single-Slot Expansion Management Module
installed in each subsequent chassis in the stack.
Installation . . . . . . . . . . . . . . . . . .4
Network Management . . . . . . . . .6
Operation . . . . . . . . . . . . . . . . . . .7
Technical Specifications . . . . . . . .9
Troubleshooting . . . . . . . . . . . . .10
Compliance Information . . . . . . .12
CPSMM-200 / CPSMM-210
Installation
Installation -- Continued
Single Chassis Option
Redundant Management Option
The CPSMM-200 management module is designed be installed into a
Transition Networks PointSystem™ chassis to enables network management
of any media converter slide-in-modules installed in the chassis. The
following chassis are available:
CPSMC19xx-100, 19-slot PointSystem™ chassis
TX PWR
RX LNK
RESET
DB-9
12C-1
TERM
MCCM10
MGMT MASTER
12C-1
OUTPORT
INIT 12C
INPORT
OUTPORT
INIT 12C
INPORT
RESET
Another CPSMM-200
managment module is
installed in the next
chassis as a backup
The CPSMM-200 management module is installed
in one of the Transition Network PointSystemTM chassis.
(Configuration for the 13-slot, 18-slot, or 19-slot chassis is shown.)
TERM
10BASE-T
RX LNK
MCCM10
MGMT MASTER
10BASE-T
TX PWR
DB-9
•
12C-1
CPSMC18xx-xxx, 18-slot PointSystem™ chassis
OUTPORT
•
INIT 12C
CPSMC13xx-100, 13-slot PointSystem™ chassis
RX LNK
RESET
INPORT
•
TX PWR
TERM
CPSMC0800-100, 8-slot PointSystem™ chassis
The CPSMM-200
management module is
installed in the first
chassis in the series
10BASE-T
•
An alternative setup involves installing two CPSMC-200 dual-slot master
management modules into two adjacent chassis for redundant management.
Redundant management can also be set up with the two CPSMM-200
modules installed in the same chassis.
Cascade Option
The management module cascade option allows the network administrator to
connect up to eight (8) PointSystem™ chassis into one manageable stack,
providing a single management source for up to 143 conversion devices.
To create the cascade option, the CPSMM-200 dual-slot master management
module is installed in the first chassis in the series. The CPSMM-210 singleslot expansion management module is installed in each subsequent chassis.
•
If there are two management modules installed in the same network, the
stand-by module will continue to manage the network while the primary
module is replaced. Also, the stand-by module will retain all network
settings.
•
If there is only one management module installed, all SNMP management
operations will cease once the module is removed. The newly installed
management module must be reconfigured to resume network
management.
RESET
DB-9
12C-1
OUTPORT
INIT 12C
INPORT
TERM
RESET
Pwr
INIT
TERM
Replacing the CPSMM-210
12C-1
12C
The CPSMM-210 can also be hot-swapped. However, unlike the CPSMM200, the network’s management settings do not need to be reconfigured if the
CPSMM-210 is replaced.
RESET
Pwr
INIT
TERM
For more information on installing or replacing the management modules, see
the user’s guide for the chassis in which the module will be installed. The
chassis manuals can be found on the Web at: www.transition.com.
12C-1
12C
4
The CPSMM-200 can be hot-swapped, that is, it can be replaced while the
PointSystem™ chassis is powered. However, please note that:
RX LNK
MCCM10
MGMT MASTER
The CPSMM-210
management module is
installed in each
subsequent chassis
Replacing the CPSMM-200
TX PWR
10BASE-T
The CPSMM-200
management module is
installed in the first
chassis in the series
In this set-up, the two modules auto-negotiate; where one is the primary
module while the other is in stand-by mode. If the primary module fails, the
stand-by module automatically takes over and manages the network.
24-hour Technical Support: 1-800-260-1312
International: 00-1-952-941-7600
techsupport@transition.com -- Click the “Transition Now” link for a live Web chat.
5
CPSMM-200 / CPSMM-210
Network Management
Operation -- Continued
CPSMM100 Firmware
LED Indicators
The Transition Networks CPSMM100 Firmware is embedded in the CPSMM200 management module. The firmware includes:
•
a Command-Line Interface (CLI),
•
a Telnet server,
•
a Web browser, and
•
an SNMP agent.
Both the CPSMM-200 and the CPSMM-210 have a power LED:
PWR On = The management module is receiving power from the chassis.
Each of these applications can be accessed either through the module’s DB-9
serial port or RJ-45 Ethernet port, which allows the network administrator to
monitor and control the network from an attached terminal or from a remote
location.
TX PWR
LEDs
10BASE-T
Reset
RX LNK
Power
FocalPoint™ 2.0 Management Application
Reset
LED
Reset
Switch
IN
IN
SERIAL
OUT
OUT
Transition Networks FocalPoint™ 2.0 management application can be
installed in a networked computer to provide a graphical user interface to
monitor the network. The version on the enclosed CD supports all features of
the enclosed CPSMM100 Firmware as well as all Transition Networks slide-inmodules that are available at the time the CD was produced.
Reset
Switch
NOTE: For detailed information on how to:
•
Set up and configure a network using the CPSMM100 Firmware.
•
Use the Command-Line Interface, Telnet server, or Web browser.
•
Install and use the FocalPoint™ 2.0 management application.
See the FocalPoint™ 2.0 Management Application and CPSMM100 Firmware
User’s Guide on the enclosed application CD. It can also be viewed on the
Transition Networks website at: www.transition.com.
Operation
Reset Switch
Both the CPSMM-200 and the CPSMM-210 have a reset switch which resets
only the management module (not the entire chassis in which the module has
been installed).
6
24-hour Technical Support: 1-800-260-1312
International: 00-1-952-941-7600
CPSMM200
CPSMM-200
CPSMM210
CPSMM-210
The CPSMM-200 management module also has three additional status LEDs,
which are used to monitor the operation of the management module in the
network.
LNK
On =
A link has been established via the DB-9 serial port or
the RJ-45 Ethernet port.
RX
Flashing =
The management module is receiving data via the DB9 serial port or the RJ-45 Ethernet port.
TX
Flashing =
The management module is transmitting data via the
DB-9 serial port or the RJ-45 Ethernet port.
techsupport@transition.com -- Click the “Transition Now” link for a live Web chat.