1 door digital keypad - Global Security Devices

YOUR SECURITY IS OUR PRIORITY
Features
Other products from GSD
“Wireless Network
System”
GSD Wi-Enterprise/Wi-Plus System is the
next generation in access control solutions.
It provides a Wireless Network throughout
the premises, giving the convenience and
security of a fully networked system for a
fraction of the cost.
For more information on the Wireless Network System visit our website
www.globalsecurity.ie
Global Security Devices Ltd
No. 3 Broomhill Business Complex,
Tallaght, Dublin 24, Ireland.
Telephone: +353 1 524 2691.
Email: info@globalsecurity.ie
www.globalsecurity.ie
Installer Name :
Contact Details :
Installation Date :
Controls 1 Door
50 Users
Door Monitoring via Door Contact
Tamper Resistant
Easy Programming
Programmable Settings:
- Number of PIN code Digits
- Engineer Code
- Relay Active Time
- Door Ajar Time
- Door Bell Time
- Silent or Audible Operation
- Duress PIN Codes
- Door Toggle Operation
- Door Forced Alarm
- Anti-Tail Gate Operation
- Keypad Backlight
- Invalid PIN Lockout
- Inputs/Outputs Options
Indoor/Outdoor Use - IP 67
Robust Polycarbonate Housing
Mounts onto Standard Electrical Patress Box
1 door digital keypad
Operation Instruction:
Enter PIN code to Open Door
Administration Notes
User Administrator
User
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
User Name
Detach outer pages
and give to end user.
PIN Number
Detach outer pages
and give to end user.
User
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
User Name
Administration Notes
PIN Number
YOUR SECURITY IS OUR PRIORITY
Other products from GSD
“Wireless Network
System”
GSD Wi-Enterprise/Wi-Plus System is the
next generation in access control solutions.
It provides a Wireless Network throughout
the premises, giving the convenience and
security of a fully networked system for a
fraction of the cost.
For more information on the Wireless Network System visit our website
www.globalsecurity.ie
Global Security Devices Ltd: No.3 Broomhill Business Complex, Tallaght,
Dublin 24, Ireland, Phone: +353 (1) 524 2691, Email: info@globalsecurity.ie
www.globalsecurity.ie
Contents
Features
2
Quick Reference
3
Operation Instructions
4
Installation Diagrams
8
Wiring Diagrams
10
1 door digital keypad
Installation & User Manual
V2.04
2
Quick reference
Features
Quick Reference - Menu Codes
Technical Specs
Power Supply
Current consumption
Current consumption with load (max)
Relay Contact Rating
Operating Temperature
Moisture Resistance
Dimensions - Flush Mount
- Surface Mount
12 - 24V AC or DC
100mA
130mA
5 Amps /240V ac
- 20 C to +60 C
IP 67
W. 87mm D. 21mm H. 119mm
W. 87mm D. 35mm H. 119mm
Features
Controls 1 Door
50 Users
Door Monitoring via Door Contact
Tamper Resistant
Easy Programming
Programmable Settings:
- Number of PIN code Digits
- Engineer Code
- Relay Active Time
- Door Ajar Time
- Door Bell Time
- Silent or Audible Operation
- Duress PIN Codes
- Door Toggle Operation
- Door Forced Alarm
- Anti-Tail Gate Operation
- Keypad Backlight
- Invalid PIN Lockout
- Inputs/Outputs Options
Indoor/Outdoor Use - IP 67
Robust Polycarbonate Housing
Mounts onto Standard Electrical Patress Box
Code
Description
Default Settings
01
Add a User PIN to Door 1
1111
03
Remove a User PIN
10
Change the Number of PIN Digits
11
Change the Engineer Code
12
Change the Relay Active Time
5 seconds (0-255)
13
Change the Door Ajar Time
30 seconds (2-255)
14
Change the Door Bell Time
3 seconds (1-10)
20
Set Silent Operation on/off
Off
21
Set Ajar Alarm on/off
On
22
Set Door Bell on/off
On
23
Set Duress codes on/off
Off
24
Set Toggle Relay on/off
On
25
Set Door Forced Alarm on/off
On
26
Set Anti-Tail Gate on/off
Off
27
Set Constant Backlight on/off
On
28
Set Invalid PIN Lockout on/off
On (3 Retries)
30
Change the Input and Output Options
0
55
Restore Factory Default Settings
4 digit PIN (4,5,6 only)
6666
3 Step Quick Setup :
Step 1, Restore Factory Default Settings..
X key then
Engineer
Code
+
Code = 55
+
Step 2, Change the Engineer Code..
X key then
Engineer
Code
+
Code = 11
+
Enter New
Engineer
Code
Code = 01
+
XXXX
User PIN
Step 3, Add a User PIN.
X key then
Engineer
Code
+
+
3
4
Operation Instructions
Operation Instructions
Factory Default PIN codes
5
Removing User PINs
The following PIN codes are the Factory Default Settings:
Code Description
03 Remove any User PIN
- The Default Engineer code is ‘6666’
- User PIN ‘1111’
Example: To Remove User PIN ‘4545’
Note: The User PIN ’1111’ is deactivated when the first User PIN is added to
the keypad.
X key then
Engineer
Code
+
Code = 03
+
PIN = 4545
+
+
Enter 0-1
Refer to
Table 1
Restoring Factory Settings
Code
55
Description
Restore Factory Default Settings
Example:
X key then
Engineer
Code
+
Changing Input/Output Options
Code = 55
Code Description
30 Change the Input and Output Options
+
Note: If Engineer Code is lost, Remove the Security Caps (see page 9) and
hold down the X key during power-up and enter the default Engineer
Code ‘6666’ immediately.This will restore the factory settings.
Example:
X key then
Engineer
Code
+
Code = 30
Adding User PINs
Table 1
Code Description
01 Add a Standard User or a Toggle User
Example: To Add User PIN ‘5656'
X key then
Engineer
Code
+
Code = 01
+
PIN = 5656
+
Example: To Add Toggle User PIN ‘1234’
X key then
Engineer
Code
+
Code = 01
+
Option
Input 1
Input 2
Output 1
Wiring
Diagrams
0
Default
Door Exit
Button
Door
Contact
Alarm/
Buzzer
Page 8
1
Door Exit
Button
Door
Contact
Follow
Relay
Page 8
1 = Toggle User
PIN = 1234
+
1
Standard User: The Door opens for the duration of Relay Active Time.
Toggle User: The Door remains open permanently on entering the PIN code.The
Door will only close after entering the PIN code a second time. Toggle Relay setting
must be set to ON to enable this feature.
Warning: Do not use a Toggle User with a strike lock as lock will remain active.
Follow Relay: OP1 will follow the state of the relay.If the relay is activated then OP1
will also be activated.
Operation Instructions
6
Operation Instructions
Turning Features ON or OFF
Changing Relay Times and Engineer Codes
Code
10
11
12
13
14
Description
Change the Number of PIN Digits
Change the Engineer Code
Change the Relay Active Time
Change the Door Ajar Time
Change the Door Bell Time
Default Settings
4 digit PIN (4,5,6 only)
6666
5 seconds (0-255)
30 seconds (2-255)
3 seconds (1-10)
Note: The Number of PIN digits can not be reduced once a User Pin has
been added.
Example: To Change the Engineer Code.
X key then
Engineer
Code
+
Code = 11
+
+
Code = 12
+
14
Seconds
+
Code = 12
+
0
Seconds
Default Settings
Off
On
On
Off
On
On
Off
On
On (3 Retries)
1= On
X key then
Engineer
Code
+
+
Number of PIN Digits is the number of digits each User PIN will contain (4 or 5 or 6).The
number can not be reduced once a User PIN has been added. If the number of PIN digits
is increased then add leading Zeros to all existing PIN’s.
E.G if increasing PIN digits from 4 to 5 then existing PIN code ‘1234’ changes to ‘01234’
Relay Active Time is the amount of time the relay will remain active. Entering 0 for the
relay active time will generate a 200millisecond pulse.
Ajar Alarm Time is the amount of time the door can remain open before activating the
alarm.
Door Bell Time is the amount of time the alarm/buzzer output will activate when the tick
key is pressed.
Description
Set Silent Operation on/off
Set Ajar Alarm on/off
Set Door Bell on/off
Set Duress codes on/off
Set Toggle Relay on/off
Set Door Forced Alarm on/off
Set Anti-Tail Gate on/off
Set Constant Backlight on/off
Set Invalid PIN Lockout on/off
Example: To Set the Backlight to always stay ON.
Example: To Change the Relay Active Time to a 200msec pulse (set time = 0 secs)
X key then
Engineer
Code
Code
20
21
22
23
24
25
26
27
28
Note: 0 = Off
New
Engineer
Code
Example: To Change the Relay Active Time to 14 seconds.
X key then
Engineer
Code
7
+
Code = 27
+
1
(ON)
Example: To Set the Backlight to stay ON for 10 seconds only after a key press...
X key then
Engineer
Code
+
Code = 27
+
0
(OFF)
Silent Operation - If this option is set, all audible tones are silenced.
Duress Codes - If this option is set, the door will open but the alarm will be activated to
an intruder alarm if the duress PIN code is entered. (A duress PIN code is the code
above the user PIN code
e.g. user code=8888 then duress code=8889).
Toggle Relay - If this option is set, then the door will remain open or closed on each
PIN entry for a Toggle User.
Door Forced Alarm – This alarm will activate if the door contact is forced open.
Anti-Tail Gate – If this option is set, the door relay time is shortened to 2 seconds,
after the door contact has opened and then closed.
Constant Backlight – If this option is set, the backlight remains on, otherwise it
will turn on only after a key press and switch off after 10 seconds.
Invalid PIN Lockout – Entering an invalid PIN 3 times will lockout the keypad for
15 seconds. All lights will flash during this time. Turning this feature off reduces the
security of the keypad.
8
Installation Diagrams
Installation Diagrams
9
Flush Mounting
When Surface Mounting the Keypad
a Surface Mount Collar is required.
- Fix Surface Mount Collar to
wall, ensure arrow is
pointing upwards
Keypad is mounted to electrical pattress box using security
screws provided. Both Security Caps are
then clipped onto Keypad.
Surface Mounting
After fixing Surface Mount Collar to wall
(as above) and wiring is complete as per
wiring diagrams on pages 10-11, the Keypad
may then be screwed to Surface
Mount Collar using security
screws provided.
Both Security Caps are
then clipped onto keypad
To attach Security Caps: Simply
align the tabs into holes and push
on until click is heard.
To release Security Caps push a
screwdriver into slots on the side
and pull forward.
Security Caps
To attach Security Caps: Simply
align the tabs into holes and push
on until click is heard.
10
Wiring Diagrams 11
Wiring Diagrams
Wiring Diagrams Option 0
Wiring Diagrams Option 1
Door Exit Button
Door Exit Button
12V Linear
Power supply
12V Linear
Power supply
0V
0V
Door
Contact
12V
Door
Contact
12V
12V
IP1
IP2
0V
OP1
NO
COM TAMP
TAMP
NC
0V
0V
12V
Door MagLock
12V
IP1
IP2
0V
OP1
NO
COM TAMP
TAMP
NC
0V
0V
Sounder
Door MagLock
Follow Relay
Volt Free
Tamper Contacts
1 and 2
Volt Free
Tamper Contacts
1 and 2
12 - 24 VAC
This OP is active
when the relay is
activated.
12 - 24 VAC
12V
0V
NO
COM
NC
12V
0V
NO
COM
NC
12 - 24 VAC
12 - 24 VAC
0V
Wiring for StrikeLock using 12 - 24VAC supply
Note: All OV shown in the diagram are connected
to OV at the back of the keypad terminal block.
0V
Wiring for StikeLock only using 12 - 24VAC supply
Note: All OV shown in the diagram are connected
to OV at the back of the keypad terminal block.
Download PDF