RuggedSwitch® i 800
Compact Managed Industrial Ethernet Switch with Fiber Optics, 128-bit Encryption
The RuggedSwitch® i800, or i-Series, is a family of compact,
fully managed Ethernet switches designed to operate reliably in
harsh industrial environments. The flexibility of the i800 family
allows the user to choose from managed or unmanaged, regular
or extended temperature, fiber optical or copper interfaces, and
fast or Gigabit Ethernet. With up to nine Ethernet ports, the i800
is the perfect choice for a wide variety of demanding industrial
environments such as those found in process control applications
(oil and gas, petro-chemical, metals and mining, wind farms).
The i800 is packaged in a compact, die cast aluminum, DIN
mountable enclosure for efficient use of cabinet space. Dual
24VDC power inputs increase reliability in case of primary power
supply faults. The i800 provides a high level of immunity to
electromagnetic interference and heavy electrical surges typical
of environments found in industrial applications. An operating
temperature range of -20 to +60°C (with optional -40 to +85°C),
coupled with hazardous location certification (Class 1 Division 2)
allows the i800 to be placed in almost any location.
The i800 features a full array of intelligent functionality for high
network availability and manageability. The embedded Rugged
Operating System (ROS®) provides advanced layer 2 and layer
3 networking functions, and advanced cyber security features.
The Enhanced Rapid Spanning Tree Protocol (eRSTP™) ensures
very fast network recovery in case of failures ensuring a high
availability network and allows any topology from ring to mesh.
Numerous other features like VLANs and QoS make the i800 an
enterprise class switch in an industrial class package.
The i800 is backed by an industry leading five year warranty and
unsurpassed technical support and service.
Features and Benefits
Ethernet Ports
„„
Four models to choose from with up to 8 10/100 BaseTX ports
and up to 3 fiber ports
„„
i 800: 8x 10/100TX
„„
i 801: 8x 10/100TX + 1x 1000LX or
1x 10/100/1000TX
„„
i 802: 6x 10/100TX + 1x 100FX or 2x 100FX or
2x 1000LX or 2x 10/100/1000TX
„„
i 803: 4x 10/100TX + 1x 100FX + (2x 1000LX or 2x 100FX)
„„
Industry standard LC fiber optical connectors
„„
Multimode and Singlemode optical transceivers
www.RuggedCom.com
Cyber Security Features
„„
Multi-level user passwords
„„
SSH/SSL (128-bit encryption)
„„
Enable/disable ports, MAC based port security
„„
Port based network access control (802.1x)
„„
VLAN (802.1Q) to segregate and secure network traffic
„„
RADIUS centralized password management
„„
SNMPv3 authentication and 56-bit encryption
RuggedRated™ for Reliability in Harsh Environments
„„
Immunity to EMI and heavy electrical surges
„„
Exceeds IEC 61000-6-2 (generic industrial)
„„
Hazardous Location Certification: Class 1 Division 2
„„
-20 to +60°C operating temperature (optional -40 to +85°C)
„„
Conformal coated printed circuit boards (optional)
„„
Die cast aluminum enclosure
Rugged Operating System (ROS®) Features
„„
Simple plug and play operation - automatic learning,
negotiation, and crossover detection
„„
RSTP (802.1w) and Enhanced Rapid Spanning Tree
(eRSTP™) network fault recovery (<5ms)
„„
Quality of Service (802.1p) for real-time traffic
„„
VLAN (802.1Q) with double tagging and GVRP support
„„
Link aggregation (802.3ad)
„„
IGMP Snooping for multicast filtering
„„
Port Rate Limiting and Broadcast Storm Limiting
„„
Industrial automation features (eg. Modbus)
„„
MSTP (802.1Q - 2005, formerly 802.1s)
Management Tools
„„
Web-based, Telnet, CLI management interfaces
„„
SNMP v1/v2/v3 (56-bit encryption)
„„
Remote Monitoring (RMON)
„„
Rich set of diagnostics with logging and alarms
Power Supply
„„
Dual low-voltage DC inputs: 24VDC (10-36VDC)
„„
Compression fit connections
„„
CSA/UL 60950 safety approved to +85°C
RUGGEDCOM
ISO 9001
REGISTERED
RuggedSwitch® i 800
1
RuggedSwitch® i 800
Compact Managed Industrial Ethernet Switch with Fiber Optics, 128-bit Encryption
RuggedSwitch® i800
Power Input
XXDual 24VDC Power Inputs
Critical Alarm Relay
XXOptional Form-C Failsafe
Alarm Relay
Operating Temperature
XX
-20 to +60°C Operating
Temperature Range
XX
Optional -40 to +85°C
Rugged Construction:
XXHeavy Duty Cast
Aluminum Enclosure
HazLoc Rated
XXCompact Size
4.5”x2”x3.5”
Fast Ethernet Ports:
XX8 Ports 10/100TX Auto
Negotiation and Crossover
Console Port
XXOptional CPU
Management with ROS®
Other Available Models:
i801:8x 10/100TX + 1x 1000LX or
1x 10/100/1000TX
www.RuggedCom.com
i802: 6x 10/100TX + 2x 100FX or
2x 1000LX or 2x 10/100/1000TX
i803: 4x 10/100TX + 1x 100FX
+ (2x 1000LX or 2x 100FX)
RuggedSwitch® i 800
2
RuggedSwitch® i 800
Compact Managed Industrial Ethernet Switch with Fiber Optics, 128-bit Encryption
ROS® Features
Cyber Security
Cyber security is an urgent issue in many industries where
advanced automation and communications networks play a
crucial role in mission critical applications and where high
reliability is of paramount importance. Key ROS® features that
address security issues at the local area network level include:
„„
Passwords - Multi-level user passwords secures switch
against unauthorized configuration
„„
SSH / SSL - Extends capability of password protection
to add 128-bit encryption of passwords and data as they cross
the network
„„
Enable / Disable Ports - Capability to disable ports so that
traffic can not pass
„„
802.1Q VLAN - Provides the ability to logically segregate
traffic between predefined ports on switches
„„
MAC Based Port Security - The ability to secure ports
on a switch so only specific Devices / MAC addresses can
communicate via that port
„„
802.1x Port Based Network Access Control - The ability to
lock down ports on a switch so that only authorized clients can
communicate via this port
„„
RADIUS - authentication service using MD5 hash and
providing centralized password management
„„
SNMPv3 - encrypted authentication access security and data
encryption (CBC-DES with 56-bit encryption key)
„„
Secure Socket Layer - Web-based management using SSL
with data encryption (128-bit encryption key)
„„
RSA – 1024 bit key for key management and key exchange
„„
TACACS+ - Terminal Access Control and Accounting Services
Client provides encrypted authentication and authorization
„„
Point to Point (PPP) - using CHAP (MD5 Hash)
authentication service
„„
SFTP - Secure File Transfer Protocol using SSH encryption
The ROS® cyber security features are included to help address the
various industry specific security standards such as NERC CIP, ISA
S99, AGA 12, IEC 62443, ISO 17799:2005 and PCSRF SPP-ICS.
Enhanced Rapid Spanning Tree Protocol (eRSTP™)
RuggedCom eRSTPTM allows the creation of fault-tolerant ring
and mesh Ethernet networks that incorporate redundant links that
are ‘pruned’ to prevent loops. eRSTPTM yields worst-case fault
recovery1 of 5ms times the ‘bridge diameter’ and allows rings
of up to 160 switches. For example, a ring of ten switches will
have fault recovery times under 50ms. eRSTPTM implements
both STP and RSTP to ensure interoperability with commercial
switches unlike other proprietary ‘ring’ solutions.
Quality of Service (IEEE 802.1p)
Some networking applications such as real-time control
or VoIP (voice over IP) require predictable arrival times for
www.RuggedCom.com
Ethernet frames. Switches can introduce latency in times
of heavy network traffic due to the internal queues that buffer
frames and then transmit on a first come first serve basis. ROS®
supports ‘Class of Service’ in accordance with IEEE 802.1p
that allows time critical traffic to jump ahead to the front of the
queue thus minimizing latency and reducing jitter to allow such
demanding applications to operate correctly. ROS® allows priority
classification by port, tags, MAC address, and IP type of service
(ToS). A configurable “weighted fair queuing” algorithm controls
how frames are emptied from the queues.
VLAN (IEEE 802.1Q)
Virtual local area networks (VLAN) allow the segregation of a
physical network into separate logical networks with independent
broadcast domains. A measure of security is provided since hosts
can only access other hosts on the same VLAN and traffic storms
are isolated. ROS® supports 802.1Q tagged Ethernet frames and
VLAN trunks. Port based classification allows legacy devices to be
assigned to the correct VLAN. GVRP support is also provided to
simplify the configuration of the switches on the VLAN.
Link Aggregation (802.3ad)
The link aggregation feature provides the ability to aggregate
several Ethernet ports into one logical link (port trunk) with higher
bandwidth. This provides an inexpensive way to set up a high
speed backbone to improve network bandwidth. This feature is
also known as “port trunking”, “port bundling”, “port teaming”, and
“Ethernet trunk”.
IGMP Snooping
ROS® uses IGMP snooping (Internet Group Management
Protocol v1&v2) to intelligently forward or filter multicast traffic
streams (e.g. MPEG video) to or from hosts on the network. This
reduces the load on network trunks and prevents packets from
being received on hosts that are not involved. ROS® has a very
powerful implementation of IGMP snooping that:
„„
Can be enabled on a per VLAN basis.
„„
Detects and filters all multicast streams regardless of whether
subscribers exist.
„„
Supports “router-less” operation by supporting an “active” mode.
„„
Restores traffic streams immediately after an RSTP
topology change.
SNMP (Simple Network Management Protocol)
SNMP provides a standardized method for network
management stations the ability to interrogate devices from
different vendors. SNMP versions supported by ROS® are v1,
v2c, and v3. SNMPv3 in particular provides security features
such as authentication, privacy with data encryption (CBC-DES
with 56-bit encryption key) and access control not present in
earlier SNMP versions. ROS® also supports numerous standard
MIBs (Management Information Base) allowing for easy
integration with any network management system (NMS).
RuggedSwitch® i 800
3
RuggedSwitch® i 800
Compact Managed Industrial Ethernet Switch with Fiber Optics, 128-bit Encryption
ROS® Features
A feature of SNMP supported by ROS® is the ability to generate
“traps” upon system events. RuggedNMSTM, the RuggedCom
management solution, can record traps from multiple devices
providing a powerful network troubleshooting tool. It also
provides a graphical visualization of the network and is fully
integrated with all RuggedCom products.
1
For 100 Mbps, fault recovery performance is <5ms/hop
For 1,000 Mbps, fault recovery performance is <5ms/hop + 20msSNTP (Simple Network Time Protocol)
SNTP automatically synchronizes the internal clock of all ROS®
devices on the network. This allows for correlation of time
stamped events for troubleshooting.
ROS contains features that optimize network performance and
simplify switch management based on the unique requirements
found in SCADA and industrial automation applications. Features
such as Modbus TCP management for retrieval of switch data
using the ubiquitous Modbus protocol and DHCP Option 82,
a Rockwell Automation ODVA requirement for IP address
assignment based on the location of the end device, provide
capabilities not found in typical “commercial” or “office grade”
Ethernet switches.
®
Port Based Network Access Control (802.1x)
ROS supports the IEEE 802.1x standard that defines a
mechanism for port-based network access control which
provides a means of authenticating and authorizing devices
attached to LAN ports.
®
Port Rate Limiting
ROS supports configurable rate limiting per port to limit unicast
and multicast traffic. This can be essential to managing precious
network bandwidth for service providers. It also provides edge
security for denial of service (DoS) attacks.
®
Broadcast Storm Filtering
Broadcast storms wreak havoc on a network and can cause
attached devices to malfunction. This could be disastrous on
a network with mission critical equipment. ROS limits this by
filtering broadcast frames with a user-defined threshold.
®
Some intelligent electronic devices (IEDs) have dual fiber optic
ports with automatic failover to a backup port should the primary
fail. ROS ensures this mechanism works reliably under all failure
modes by appropriately disabling link signals when required.
ROS also flushes learned MAC addresses to ensure the failover
occurs quickly.
®
www.RuggedCom.com
Port Configuration and Status
ROS allows individual ports to be ‘hard’ configured for speed,
duplex, auto-negotiation, flow control and more. This allows
proper connection with devices that do not negotiate or have
unusual settings. Detailed status of ports with alarm and SNMP
trap on link problems aid greatly in system troubleshooting.
Port Statistics and RMON (Remote Monitoring)
SCADA and Industrial Automation
®
®
®
eRSTP fault recovery times may be approximated as follows:
Loss of Link Management
Port Mirroring
ROS can be configured to duplicate all traffic on one port to a
designated mirror port. When combined with a network analyzer,
this can be a powerful troubleshooting tool.
ROS provides continuously updating statistics per port that
provide both ingress and egress packet and byte counters as
well as detailed error figures. Also provided is full support for
the RMON statistics, history, alarms, and event groups. RMON
allows for very sophisticated data collection, analysis and
detection of traffic patterns.
®
Event Logging and Alarms
ROS records all significant events to a non-volatile system log
allowing forensic troubleshooting. Events include link failure and
recovery, unauthorized access, broadcast storm detection, and
self-test diagnostics among others. Alarms provide a snapshot of
recent events that have yet to be acknowledged by the network
administrator. An external hardware relay is de-energized during
the presence of critical alarms allowing an external controller to
react if desired.
®
HTML Web Browser and Telnet User Interfaces
ROS provides a simple, intuitive user interface for configuration
and monitoring via a standard graphical web browser or via
Telnet. All system parameters include detailed on-line help to
make setup a breeze. ROS , presents a common look and feel
and standardized configuration process allowing easy migration
to other RuggedCom managed products.
®
®
Configuration via ASCII Text File
All configuration parameters are stored in an ASCII formatted
text file that can easily be transferred via TFTP or Xmodem.
The configuration file can be saved for backup purposes and
easily manipulated by a text editor. The same text file can be
downloaded to the switch at a later date in order to re-configure
or restore a previous configuration.
Command Line Interface (CLI)
A command line interface can be used in conjunction with
remote shell to automate data retrieval, configuration updates,
and firmware upgrades. A powerful SQL-like capability allows
expert users the ability to selectively retrieve or manipulate any
parameters the device has to offer.
RuggedSwitch® i 800
4
RuggedSwitch® i 800
Compact Managed Industrial Ethernet Switch with Fiber Optics, 128-bit Encryption
EMI and Environmental Type Tests
Test
IEC 61000-4-2
IEC 61000-4-3
IEC 61000-4-4
IEC 61000-6-2 EMC Generic Standard: Immunity for Industrial Environments
Description
Enclosure Contact
ESD
Enclosure Air
Radiated RFI
Enclosure ports
Signal ports
Burst (Fast Transient)
D.C Power ports
IEC 61000-4-5
Surge
IEC 61000-4-6
Induced (Conducted) RFI
Levels
+/- 4kV
+/- 8kV
10 V/m, 80 to 1000Mhz
+/- 1kV @ 5kHz
+/- 2kV @ 5kHz
Signal ports
+/- 1kV line-to-earth
D.C Power ports
+/- 0.5kV line-to-earth/line
Signal ports
10V @ 0, 5-80 MHz
D.C Power ports
10V @ 0, 5-80 MHz
Earth ground ports
10V @ 0, 5-80 MHz
IEC 61000-4-8
Magnetic Field
Enclosure ports
30 A/m @ 50, 60 Hz
IEC 61000-4-29
Voltage Dips
D.C. Power ports
30% reduction for 0.5 period
Signal ports
IEC 61000-4-12
Damped Oscillatory
2.5kV common,
1kV diff. mode@1MHz
D.C. Power ports
2.5kV common,
1kV diff. mode@1MHz
Signal ports
30V Continuous, 300V for 1s
D.C. Power ports
30V Continuous, 300V for 1s
D.C. Power ports
10%
IEC 61000-4-16
Mains Frequency Voltage
IEC 61000-4-17
Ripple on D.C. Power Supply
IEEE 1613 (C37.90.x) EMI IMMUNITY TYPE TESTS
Test
Description
IEEE C37.90.3
ESD
IEEE C37.90.2
Radiated RFI
IEEE C37.90.1
Fast Transient
IEEE C37.90.1
Oscillatory
IEEE C37.90
H.V. Impulse
IEEE C37.90
Dielectric Strength
Test
IEC 60068-2-1
IEC 60068-2-2
IEC 60068-2-30
IEC 60255-21-1
IEC 60255-21-2
www.RuggedCom.com
Enclosure Contact
Enclosure Air
Enclosure ports
Signal ports
D.C. Power ports
Earth ground ports3
Signal ports
D.C. Power ports
Signal ports
D.C. Power ports
Signal ports
D.C. Power ports
Test Levels
+/- 8kV
+/- 15kV
35 V/m
+/- 4kV @ 2.5kHz
+/- 4kV
+/- 4kV
2.5kV common mode @1MHz
2.5kV common, 1kV diff. mode@1MHz
5kV (Fail-Safe Relay output)
5kV
2kVac
1.5kV DC
Environmental Type Tests
Description
Cold Temperature
Test Ad
Dry Heat
Test Bd
Humidity (Damp Heat, Cyclic)
Test Db
Vibration
Tests Fc
Shock
Tests Ea
Severity Levels
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
Test Levels
-40°C, 16 Hours
+85°C, 16 Hours
95% (non-condensing), 55°C , 6 cycles
1g @ (10 - 500) Hz
30g @ 11mS
RuggedSwitch® i 800
5
RuggedSwitch® i 800
Compact Managed Industrial Ethernet Switch with Fiber Optics, 128-bit Encryption
Technical Specifications
Power Supply
„„
Power Consumption: 9W MAX
„„
10-36 VDC, 0.4A @ 24VDC’
„„
Non-isolated
Critical Alarm Relay
„„
Form-C failsafe contact relay: 1A@30VDC
Physical
„„
Height: 4.5” /11.4cm
„„
Width: 2” / 5.1cm
„„
Depth: 3.5” / 8.9cm
„„
Weight: 2.2lbs / 1.0kg
„„
Ingress Protection: IP40 (1mm objects)
„„
Enclosure: Cast Aluminum Enclosure
„„
Mounting: DIN rail
Switch Properties
„„
Switching method: Store & Forward
„„
Switching latency: 8 us (100Mbps)
„„
Switching bandwidth: 5
.2Gbps
(for i802 6x100bps ports + 2xGig ports)
„„
MAC address table size: 16kbytes
„„
Priority Queues: 4
„„
Frame buffer memory: 1 Mbit
„„
Simultaneous VLANs: 255
„„
VLAN ID Range: 1 to 4094
„„
IGMP multicast groups: 256
„„
Port rate limiting: 128kbps, 256, 512, 4, 8Mbps
„„
No head of line blocking
Approvals
„„
Hazardous Location: cUL 1604 Class 1 Div 2 (Hazloc)
„„
ISO: Designed and manufactured using a ISO9001: 2000
certified quality program
„„
CE Marking
„„
Emissions: FCC Part 15 (Class A),
EN55022 (CISPR22 Class A)
„„
Safety: cUL508 (UL508/CSA C22, EN61010-1)
„„
Laser Eye Safety (FDA/CDRH): Complies with 21
CFR Chapter1, Subchapter J.
„„
ATEX Zone 2 (IEC/EN 60079-15)
Warranty
„„
5 Years – Applicable to design or manufacturing related
product defects.
„„
Note: The i800 product family has been designed specifically
for the Industrial Automation segment, and as such
RuggedCom does not recommend the use of this product
family for Electric Utility Substations applications. Should these
products be used for Electric Utility Substation Applications,
the following applies,
zz
Product performance is not guaranteed
zz
The manufacturers warranty will not be applicable (i.e. it
will be voided and technical support will not be provided)
zz
RuggedCom does not accept any liabilities as a result of
Network Management
„„
HTTP graphical web-based, SSL (128-bit encryption)
„„
SNMP v1, v2c, v3 (56-bit encryption)
„„
Telnet, VT100, SSH/SFTP (128-bit encryption)
„„
Command Line Interface (CLI)
„„
RSA Key Management (1024 bit key)
„„
Authentication and Accounting - TACACS+ (encrypted), RADIUS
client, PPP
IEEE Compliance
„„
802.3-10BaseT
„„
802.3u-100BaseTX, 100BaseFX
„„
802.3x-Flow Control
„„
802.3z-1000BaseLX
„„
802.3ab-1000BaseTX
„„
802.3ad-Link Aggregation
„„
802.1D-MAC Bridges
„„
802.1D-Spanning Tree Protocol
„„
802.1p-Class of Service
„„
802.1Q-VLAN Tagging
„„
802.1w-Rapid Spanning Tree Protocol
„„
802.1x-Port Based Network Access Control
„„
802.1Q-2005 (formerly 802.1s) MSTP
IETF RFC Compliance
„„
RFC768-UDP
„„
RFC783-TFTP
„„
RFC791-IP
„„
RFC792-ICMP
„„
RFC793-TCP
„„
RFC826-ARP
„„
RFC854-Telnet
„„
RFC894-IP over Ethernet
„„
RFC1112-IGMP v1
„„
RFC1519-CIDR
„„
RFC1541-DHCP (client)
„„
RFC2030-SNTP
„„
RFC2068-HTTP
„„
RFC2236-IGMP v2
„„
RFC2284-EAP
„„
RFC2475-Differentiated Services
„„
RFC2865-RADIUS
„„
RFC3414-SNMPv3-USM
„„
RFC3415-SNMPv3-VACM
IETF SNMP MIBS
„„
RFC1493-BRIDGE-MIB
„„
RFC1907-SNMPv2-MIB
„„
RFC2012-TCP-MIB
„„
RFC2013-UDP-MIB
„„
RFC2578-SNMPv2-SMI
„„
RFC2579-SNMPv2-TC
„„
RFC2819-RMON-MIB
„„
RFC2863-IF-MIB
„„
draft-ietf-bridge-rstpmib-03-BRIDGE-MIB
„„
draft-ietf-bridge-bridgemib-smiv2-03-RSTP-MIB
„„
ANAifType-MIB
performance issues
www.RuggedCom.com
RuggedSwitch® i 800
6
RuggedSwitch® i 800
Compact Managed Industrial Ethernet Switch with Fiber Optics, 128-bit Encryption
Fiber Specifications and Mechanical Drawing
Parameter
Mode
Connectors
Typical Dist. (km)
Optical Wavelength (nm)
Cable SizeCore/Cladding (um)
TX Power (dBm)
Rx Sensitivity (dBm)
Typical Budget (dB)
Fiber Optical Specifications
Fiber Port Type
Multimode
LC
2
1310
50 or 62.5/125
-15.7
-33.5
17
Singlemode
LC
20
1310
8 or 9/125
-15.5
-32
16.5
Note: Other
i800 models have the same dimensions; see
install guide for complete information.
www.RuggedCom.com
RuggedSwitch® i 800
7
RuggedSwitch® i 800
Compact Managed Industrial Ethernet Switch with Fiber Optics, 128-bit Encryption
Order Codes
i 800 - ___ - ___ - ______
M T
MOD
i 801 - ___ - ___- _____ - ______
M T
P9
MOD
i 802 - ___ - ___- _____ - ______
M T P78
MOD
i 803 - ___ - ___- ____ - ______ - _____
M T P5
P6P7 MOD
M: Management Option
„„
M = Managed with ROS®
„„
U = Unmanaged
MOD: Manufacturing Modifications
„„
XX = None
„„
C01 = Conformal Coating
T: Temperature Option
„„
T = -20 to +60°C
„„
U = -40 to +85°C
P9: i 801 Port 9 Options
„„
1CG01 = 10/100/1000Base TX
„„
1FG01 = 1000SX Multilmode LC 850nm 500m
„„
1FG03 = 1000LX Singlemode LC 1310nm 10km
P78: i 802 Port 7&8 Options
„„
1FX11 = 1x 100FX Multimode LC 1310nm, 2km
„„
1FX06 = 1x 100FX Singlemode LC 1310nm, 20km
„„
FX11 = 2x 100FX Multimode LC 1310nm, 2km
„„
FX06 = 2x 100FX Singlemode LC 1310nm, 20km
„„
FG01 = 2x 1000SX Multimode LC 850nm 500m
„„
FG03 = 2x 1000LX Singlemode LC 1310nm 10km
„„
CG01 = 2x 10/100/1000TX
P5: i 803 Port 5 100FX Fiber Optic Options
„„
1FX11 = 1x 100FX Multimode LC 1310nm, 2km
„„
1FX06 = 1x 100FX Singlemode LC 1310nm, 20km
P6P7: i 803 Port 6&7 Fiber Optic Options
„„
FX11 = 2x 100FX Multimode LC 1310nm, 2km
„„
FX06 = 2x 100FX Singlemode LC 1310nm, 20km
„„
FG01 = 2x 1000SX Multilmode LC 850nm 500m
„„
FG03 = 2x 1000LX Singlemode LC 1310nm 10km
www.RuggedCom.com
RuggedSwitch® i 800
8
RuggedSwitch® i 800
Compact Managed Industrial Ethernet Switch with Fiber Optics, 128-bit Encryption
RuggedCom Inc.
300 Applewood Crescent, Unit 1,
Concord, Ontario, Canada L4K 5C7
Tel: +1 (905) 856-5288 Fax: +1 (905) 856-1995
Toll Free: 1 (888) 264-0006
Technical Support Center
Toll Free (USA & Canada): 1 (866) 922-7975
International: +1 (905) 856-5288
USA: +1 (954) 922-7975
E-mail: Support@RuggedCom.com
© 2010 RuggedCom Inc.
RuggedSwitch is a registered trademark of RuggedCom Inc.
Ethernet is a trademark of the Xerox Corporation.
Patent Pending
All specifications in this document are subject to change without notice.
Rev 2k — 06/06/12
www.RuggedCom.com
For additional information on our products and services, please
visit our web site at: www.RuggedCom.com
RuggedSwitch® i 800
9
Download PDF