20/92
Small enclosures, basic enclosures
Small enclosures
CI-K
System overview
Small enclosures
General
1
2
1
1
3
1
3
3
Protection type IP65 (except CI-K2-80-A)
Five basic sizes (floor area of enclosure lower
section)
Two overall depths per base surface
(exception: CI-K1 enclosure depth always 95 mm,
CI-K2-80-... enclosure depth always 80 mm)
Enclosure made of glass-fibre reinforced with
self-extinguishing polycarbonate, halogen free
Captive gasket
Enclosure base RAL 9005 )
Black (matt)
Enclosure cover RAL 7035, light grey (matt)
Metric cable entries
1
Mounting systems for basic enclosures
2
Mounting
3
CI-K1 and CI-K2:
metric cable entry knockouts with push-through
cable entry diaphragm in the sides, top and bottom
and also in the rear wall
CI-K1H, CI-K2H:
metric cable entry knockouts in the enclosure sides,
top and bottom
CI-K3 to CI-K5:
metric cable entry knockouts in the sides, top and
bottom and also in the rear wall
Control cable entry with CI-K2
Metric cable glands to EN 50 262
Push-through metric cable grommets
→ Page 20/95, → Chapter 16: Accessories for
control panel building
Mounting rails to IEC/EN 60 715
Sheet steel mounting plates
Accessories for mounting systems
→ Page 20/97
Horizontal and vertical slot apertures for
wall-mounting enclosures
Captive cover screws
Rubber feet on the back plate to compensate for
uneven walls for CI-K1 and CI-K2
External fixing bracket for CI-K4 and CI-K5
→ Page 4/67
Mounting units
Miniature circuit breakers (MCB)
Rotary switches
Switch-disconnectors
Contactors
easy control relays
Timing relay
Pilot devices
• Laser labelling
We can label the cover surface
of the small enclosures CI-K according to your specifications.
Washable and permanent with modern laser inscription.
Please contact:
Technical information/product advice
Tel. +49 (0)228 602-3704
Fax. +49 (0)0228 602-69403
E-mail: Technik-Bonn@eaton.com
CI-K-Combination-* → Page 20/94
Approved enclosures for use in UL/CSA → Page 20/96
• Cutouts in enclosure covers
We can drill cutouts in enclosure covers to your requirements.
Please contact:
Technical information/product advice
Tel. +49 (0)228 602-3704
Fax. +49 (0)0228 602-69403
E-mail: Technik-Bonn@eaton.com
2010 CA08103002Z-EN
www.eaton.com
Small enclosures, basic enclosures
20/93
Basic enclosures
CI-K, CI-K2, CI-K3
HPL20093EN
Ordering
Basic enclosures
Dimensions
Enclosure depth:
Dimensions from top:
1. Mounting depth for mounting
plate
2. Mounting depth for mounting
rail 7.5 mm height
3. Enclosure depth
mm
mm
Mounting depth
Features
For mounting
plate
For 7.5 mm
mounting rail
mm
mm
Part no.
Article no.
Price
See price
list
Std. pack
CI-K basic enclosures
•
•
•
•
•
•
•
•
Protection type IP65 (exception: CI-K2-80-A), material characteristic glass-fibre reinforced polycarbonate
Enclosure base RAL 9005, black/enclosure top only RAL 7035, light grey
Metric cable entry knockouts top, bottom and in the back plate
Push-through cable membrane with CI-K1 and CI-K2
Hard metric knockouts with CI-K1H and CI-K2H
Hard metric knockouts with CI-K3 to CI-K5
Control cable entry with CI-K2
Indicator light L-. can be mounted in base knock out M20/M25
82
120
L
S
L
80
72
CI-K1-95-TS
206881
CI-K1H-95-TS
105853
1 off
CI-K2-100-TS
206882
CI-K2H-100-TS
229304
CI-K2-100-M
206893
CI-K2H-100-M
229306
CI-K2-145-TS
206883
CI-K2H-145-TS
229305
CI-K2-145-M
206894
CI-K2H-145-M
229307
CI-K2-145-AD
207632
1 off
CI-K2H-145-AD
229308
1 off
CI-K3-125-TS
206884
CI-K3-125-M
206895
1 off
With mounting rail
CI-K3-160-TS
206885
1 off
With mounting plate
CI-K3-160-M
206896
1 off
–
72
With mounting rail
–
72
With mounting rail
–
73
With mounting rail
–
73
With mounting rail
79
–
With mounting plate
79
–
With mounting plate
–
118
With mounting rail
–
118
With mounting rail
124
–
With mounting plate
124
–
With mounting plate
124
–
124
–
–
93
With adapter plate for
contactor DILE with
overload relay ZE
With adapter plate for
contactor DILE with
overload relay ZE
With mounting rail
98
–
With mounting plate
–
128
133
–
1 off
95
M
T
116
160
79
73
Q
100
100
M
116
160
124
T
118
Q
100
145
N
152
200
98
U
93
1 off
1 off
1 off
1 off
1 off
1 off
1 off
1 off
1 off
R
120
125
N
U
152
200
133
128
R
120
Notes
160
Number and size of cable entries → Page 20/95
2010 CA08103002Z-EN
www.eaton.com
20/94
Small enclosures, basic enclosures
Basic enclosures
CI-K, CI-K2, CI-K3
Dimensions
Enclosure depth:
Dimensions from top:
1. Mounting depth for mounting
plate
2. Mounting depth for mounting
rail 7.5 mm height
3. Enclosure depth
mm
mm
HPL20094EN
Mounting depth
Features
For mounting
plate
For 7.5 mm
mounting rail
mm
mm
Part no.
Article no.
Price
See price
list
Std. pack
CI-K basic enclosures
•
•
•
•
•
•
•
•
Protection type IP65 (exception: CI-K2-80-A), material characteristic glass-fibre reinforced polycarbonate
Enclosure base RAL 9005, black/enclosure top only RAL 7035, light grey
Metric cable entry knockouts top, bottom and in the back plate
Push-through cable membrane with CI-K1 and CI-K2
Hard metric knockouts with CI-K1H and CI-K2H
Hard metric knockouts with CI-K3 to CI-K5
Control cable entry with CI-K2
Indicator light L-. can be mounted in base knock out M20/M25
–
93
With mounting rail
O
194
240
98
V
CI-K4-125-TS
206886
CI-K4-125-M
206897
1 off
CI-K4-160-TS
206890
CI-K4-160-M
206898
1 off
98
–
With mounting plate
–
128
With mounting rail
133
–
With mounting plate
–
93
CI-K5-125-TS
206891
1 off
98
–
With mounting rail
(Weight of fitted
components max.
0.65 kg)
With mounting plate
(weight of fitted
components max.
1.7 kg)
CI-K5-125-M
206899
1 off
–
128
CI-K5-160-TS
206892
1 off
133
–
With mounting rail
(Weight of fitted
components max.
0.65 kg)
With mounting plate
(weight of fitted
components max.
1.7 kg)
CI-K5-160-M
206900
1 off
CI-K1-COMBINATION-*
102060
CI-K2-COMBINATION-*
102061
CI-K3-COMBINATION-*
102062
CI-K4-COMBINATION-*
102063
CI-K5-COMBINATION-*
102064
1 off
93
1 off
O
160
125
133
128
1 off
160
P
234
280
98
W
93
P
200
125
133
128
160
Customised cutouts and laser inscriptions
• Only with operator only
• The necessary data (laser data, symbols, text and their respective positions) as well as the position of the cutouts
must be provided as a DXF file.
Notes
Number and size of cable entries → Page 20/95
2010 CA08103002Z-EN
www.eaton.com
1 off
1 off
1 off
1 off
Small enclosures, basic enclosures
20/95
Basic enclosures
CI-K2
HPL20095EN
Dimensions
Enclosure depth:
Dimensions from top:
1. Mounting depth for
mounting plate
2. Mounting depth for
mounting rail 7.5 mm
height
3. Enclosure depth
mm
Mounting depth
For
mounting
plate
For 7.5 mm
mounting rail
mm
mm
Part no.
Article no.
Features
Price
See price
list
Std. pack
CI-K2 basic enclosures
•
•
•
•
•
•
•
Protection type IP30, material characteristic glass-fibre reinforced polycarbonate
Enclosure base RAL 9005, black/enclosure top only RAL 7035, light grey
Metric cable entry knockouts top, bottom and in the back plate
Push-through cable entry diaphragm with CI-K2
Hard metric knockouts with CI-K2H
Control cable entry
Indicator light L-. can be mounted in base knock out M20/M25
–
M
T
–
46
With standard
cutout
dimensions
–
46
With standard
cutout
dimensions
–
70
With hinged
cover
–
70
With hinged
cover
160
46
Q
80
100
M
T
160
70
Q
80
100
115
Notes
Standard cutout dimensions and mounting rail for
mounting devices requiring 2 to 4 space units.
Push-through cable
entry membrane. Close
off of unused space
units (max. 2) using
blanking strips VST1,
→ Page 20/98
Standard cutout
dimensions and mounting
rail for mounting devices
requiring 2 to 4 space
units. Hard metric knockouts. Close off of unused
space units (max. 2) using
blanking strips VST1,
→ Page 20/98
Transparent hinged cover
for mounting devices
requiring 2 to 4 space
units. Push-through cable
entry diaphragm.
Transparent hinged cover
for mounting devices
requiring 2 to 4 space
units. Hard metric
knockouts.
CI-K2-80-A
211107
1 off
CI-K2H-80-A
229309
1 off
CI-K2-80-K
211108
1 off
CI-K2H-80-K
229310
1 off
Diaphragm grommets, cable glands → Chapter 16:
Accessories for panel construction
L
M
Knockouts
2 X M20 or pushthrough membrane up
to max. ⌀ 12 mm
N
O
P
q
R
Knockouts
Knockouts
2 x M25/20
2 x M25 or pushthrough membrane up
to max. ⌀ 16 mm
CI-K2H: 2 x M25/20
Knockouts
2 x M32/25
1 x M20
Knockouts
2 x M50/40/25
1 x M20
Knockouts
2 x M25 or pushthrough membrane
up to max. ⌀ 16 mm
and 1 push-through
membrane up to
max. ⌀ 8 mm
CI-K2H: 2 x M25/20
Knockouts
2 x M25/20
1 x M20
S
T
V
W
Back plate:
2 x push-through
membrane up to max.
⌀ 8mm
Back plate:
Back plate:
2 x push-through mem- 2 x M25/20
brane up to max. ⌀
11mm
(not for CI-K2H)
Back plate:
2 x M32/25
Back plate:
2 x M50/40/25
U
2010 CA08103002Z-EN
www.eaton.com
20/96
Small enclosures, basic enclosures
Basic enclosures for North America
CI-K...-NA
HPL20096EN
Basic enclosures for North America
Features
Part no.
Article no.
73
With mounting rail
79
With mounting plate
118
With mounting rail
124
With mounting plate
93
With mounting rail
98
With mounting plate
128
With mounting rail
133
With mounting plate
93
With mounting rail
98
With mounting plate
128
With mounting rail
133
With mounting plate
125
93
With mounting rail
160
128
With mounting rail
125
98
With mounting plate
160
133
With mounting plate
CI-K2X-100-TS-NA
231220
CI-K2X-100-M-NA
231228
CI-K2X-145-TS-NA
231221
CI-K2X-145-M-NA
231229
CI-K3X-125-TS-NA
231222
CI-K3X-125-M-NA
231230
CI-K3X-160-TS-NA
231223
CI-K3X-160-M-NA
231231
CI-K4X-125-TS-NA
231224
CI-K4X-125-M-NA
231232
CI-K4X-160-TS-NA
231225
CI-K4X-160-M-NA
231233
CI-K5X-125-TS-NA
231226
CI-K5X-160-TS-NA
231227
CI-K5X-125-M-NA
231234
CI-K5X-160-M-NA
231236
Dimensions
Mounting depth
Width
Height
Depth
mm
mm
mm
mm
Price
See price
list
Std. pack
CI-K basic enclosures
•
•
•
•
•
Protection type IP65
Enclosure base RAL 9005, black/enclosure top only RAL 7035, light grey
Approved for UL, CSA
CI-K2X…: 4 x ½ inch knockouts
CI-K3X…, CI-K4X…, CI-K5X…: smooth overall with sharp corners
100
160
100
145
120
200
125
160
160
240
125
160
200
280
280
Information relevant for export to North America
Product Standards
UL File No.
UL CCN
CSA File No.
CSA Class No.
NA Certification
Specially designed for NA
Degree of Protection
2010 CA08103002Z-EN
UL 508; CSA-C22.2 No. 14-05; CSA-C22.2 No. 94; IEC/EN 60947-3; CE marking
E54120, E337418
MITW2
12528
3211-07
UL Listed, CSA certified
Yes
IEC: IP65; UL/CSA Type 1, 3R, 4X, 12, 13 – indoor and outdoor use
www.eaton.com
1 off
Small enclosures, basic enclosures
Accessories
TS-CI, M-CI
HPL20097EN
20/97
Accessories
Mounting
position
Features
Useful
length
Part no.
Article no.
CI-K1
Crosswise
–
60 mm
CI-K2
Crosswise
–
82 mm
CI-K3
Lengthwise
and crosswise
Crosswise
–
98 mm
TS-CI-K1
206901
TS-CI-K2
206902
TS-CI-K3
206903
–
133 mm
Lengthwise
and crosswise, CI-K4
lengthwise
–
173 mm
CI-K2
–
–
–
CI-K3
–
–
–
CI-K4
–
–
–
CI-K5
–
–
–
For use with
Price
See price
list
Std. pack
Information relevant for export to
North America
10 off
UL/CSA certification not required
M-CI-K2
206906
M-CI-K3
206907
M-CI-K4
206908
M-CI-K5
206909
10 off
UL/CSA certification not required
HS25-CI
002291
HS50-CI
002292
25 off
UL/CSA certification not required
ADT200-190
002289
ADT125-110
002290
10 off
UL/CSA certification not required
Mounting rails
Height 7.5 mm, with fixing screws
7.5
CI-K4
CI-K5
TS-CI-K4
206904
TS-CI-K5
206905
Mounting plates
2 mm sheet steel with fixing screws
Accessories for mounting systems
Spacers
• For raising the mounting systems
• (4 off required for mounting plate, 2 off required for mounting rail)
–
–
by 25 mm
–
–
–
by 50 mm
–
–
–
by 10 mm
–
–
–
by 15 mm
–
2010 CA08103002Z-EN
www.eaton.com
20/98
Small enclosures, basic enclosures
Accessories
CI-K, CI-K2, CI-K3
For use with
HPL20098EN
Std. pack
Information relevant for export to
North America
AB-CI-K4/5
206914
1 off
UL/CSA certification not required
TB-CI-K
206918
1 off
UL/CSA certification not required
VST1
211258
5 off
UL/CSA certification not required
K-CI-K1/2
207451
20 off
UL/CSA certification not required
K-CI-K3
206915
K-CI-K4
206916
20 off
UL/CSA certification not required
20 off
UL/CSA certification not required
10 - 35 mm2
K-CI-K5
218488
20 off
UL/CSA certification not required
–
SK-CI-K1
226766
SK-CI-K2
226767
100 off
Terminal capacity
Part no.
Article no.
Flexible
Price
See price
list
mm2
Accessories for small enclosures CI-K
Set of external fixing brackets
To secure CI-K4 and CI-K5 directly on the wall. Each set contains four brackets.
T5B-…/I4,
–
T5-…/I5,
P3-63/I4,
P3-100/I5,
Mounting rail adapter, screw fixing
To secure enclosure on mounting
rails to IEC/EN 60715
CI-K1
–
Blanking strips
To blank off one space unit; cannot be removed from outside
CI-K2-80-A
–
N terminals, PE terminals
Screwed onto support bosses in the enclosure base plate
CI-K2-PKZ01 - 4 mm2
...
CI-K1/2
Insulated individual terminals
• With PE, N adhesive labels
• For snap-fitting onto mounting rail
CI-K3
1 - 10 mm2
CI-K4
T5B-.../I4
CI-K4-T5B-...
P3-.../I4
CI-K5
T5-.../I5
CI-K5-T5-...
P3-.../I5
Protective covers for push-through cable
membrane with CI-K1(2)
To cover push-through cable membranes
–
CI-K1 (M20)
–
2010 CA08103002Z-EN
CI-K1 (M25)
www.eaton.com
1.5 - 16 mm2
–
100 off
Small enclosures, basic enclosures
20/99
Basic enclosure, accessories
CI
HPL20099EN
Basic enclosure, accessories
Dimensions
For use with
Enclosure depth:
Dimensions from top
1. Mounting depth for
mounting plate
2. Mounting depth
Mounting depth
Dimensions
Enclosure depth
For mounting plate
mm
mm
mm
Part no.
Article no.
Price
See price
list
Std. pack
Notes
CI-B, C, D basic enclosures
•
•
•
•
Transparent cover
Metric knockouts top, bottom
With PEN terminal
IP55 individual enclosure with pre-drilled mounting plate
DIL00AM
110
L
CI-B
024315
1 off
L
149
110
L
Knockouts
2 x M20
128
87
S27
110
CI-C
031434
1 off
110
CI-D
038553
1 off
–
K6/1
002270
100 off
L
165
110
L
128
110
DIL0AM
S27
110
222
L
L
128
110
PE terminal (fifth conductor)
Rated operational current 25 A
for ⌀ 1.5 - 6 mm2 solid
–
CI-B
CI-C
CI-D
–
Information relevant for export to North America
UL/CSA certification not required
2010 CA08103002Z-EN
www.eaton.com
20/100 Small enclosures, basic enclosures
Small enclosures CI-K
CI-K
Technical data
Small enclosures CI-K
CI-K1
General
Standards
CI-K2
CI-K2...-80-A
CI-K2...-80-K
Ambient temperature
°C
IEC/EN 60529
DIN 43660
EN 50262
Damp heat, constant, to IEC 60068-2-78
Damp heat, cyclic, to IEC 60068-2-30
-25 - 70
Ambient air temperature with push-through cable entry
°C
-25…40
Climatic proofing
Protection type
Front IP65
Front IP30
CI-K3
CI-K4
CI-K5
Front IP65
The degree of protection specifications do not apply to CI-K2-80-A
Protection type with push-through cable entry
IP65
IP30
IP65
Radiated heat dissipation
→ Page 20/101
Material properties
Material
Base, cover
Glass-fibre reinforced polycarbonate
Surface treatment
Corrosion-resistant
Color
Base
RAL 9005, black (matt)
Cover
Enclosure cover RAL 7035, light grey (matt)
Material properties
Electrical
Creepage resistance to IEC 60112
Base
CTI 175
Cover
CTI 175
Surface treatment to IEC 60093
Ω x 1013
>1
Dielectric strength to IEC 60243-1
kV/mm
30
Housing
°C
-40…120
Sealing
°C
-40…80
Thermal
Continuous thermal stability
Mechanical
IK code to EN 50102
04
06
06
06
06
06
Weight of fitted components
Per mounting rail
kg
0.2
0.7
0.7
0.85
0.75
0.65
With mounting plate
kg
–
–
0.7
0.85
0.9
1
Chemical resistance
Base, cover
Resistant
Acids < 10 %, mineral oil, petrol, grease, saline solutions
Partially resistant
Acids > 10 %, Alcohol
Non-resistant
Alkalis, benzol
Push-through membrane (CI-K1/CI-K2) and sealing material
Resistant
–
–
–
Partially resistant
Acids < 10 %, alkalis, alcohol,
saline solutions
Acids < 10 %, grease, benzene
–
–
–
Non-resistant
Mineral oil, petrol
–
–
–
650/1 mm thick
–
–
–
HB
–
–
–
Yes
–
–
–
Atmospheric
Saline spray
IEC 60068-2-11
UV resistance
Beneath protective canopy
Water absorption to EN ISO 62
%
0.29
°C
960/1 mm thick
Flammability characteristics
Glow-wire test
Base, cover
Glow wire to VDE 0471 Part 2
According to UL 94
Push-through membrane (CI-K1/CI-K2) and sealing
material
To VDE 0471 Part 2
According to UL 94
Halogen free
Notes
2010 CA08103002Z-EN
VO/1.5 mm thickness
°C
The degree of protection specifications do not apply to CI-K2-80-A
www.eaton.com
Small enclosures, basic enclosures 20/101
Small enclosures CI-K
Small enclosures CI-K
Small enclosures CI-K
CI-K...
Radiated heat dissipation
Part no.
Max. radiated heat dissipation of the insulated enclosures CI-K with separate
mounting, ambient air temperature +20 °C
Heat dissipation
CI-K1-95
Dimensions
WxHxD
mm
80 x 137 x 95
CI-K2-100
CI-K2-145
CI-K3-125
CI-K3-160
CI-K4-125
CI-K4-160
CI-K5-125
CI-K5-160
100 x 181 x 100
100 x 181 x 145
120 x 222 x 125
120 x 222 x 160
160 x 240 x 125
160 x 240 x 160
200 x 280 x 125
200 x 280 x 160
12.5
18.5
21.5
25.5
26
29.5
35
41
W
10
2010 CA08103002Z-EN
www.eaton.com
20/102 Small enclosures, basic enclosures
Dimensions
Small enclosures
CI-K…
Small enclosures
Small insulated material enclosures
CI-K1...-95-TS
Mounting rails
35
17.5
TS-CI-K1
39
4.7
5
7.5
61
45
4.5
74
137
82
120
127
12
1.5
72
37.5
80
57.5
39
95
b
52.5
97.5
5.2
4.7
52
92
1.5
65
100
18
116
181
171
160
116
4.5
b
47.5
100
7.5
77
7
57
5
TS-CI-K2
35
a
100
145
Mounting rails
M-CI-K2
7.5
22
Part no.
CI-K2-100-...
CI-K2-145-...
Mounting plates
92
CI-K2-...
46
a
a
125
160
Mounting rails
M-CI-K3
TS-CI-K3
b
74.5
109.5
7.5
24.5
Part no.
CI-K3-125-...
CI-K3-160-...
Mounting plates
35
CI-K3-...
108
20
22
52
5.2
5.3
70
116
65
5.5
140
222
200
210
152
27
1.5
5
b
50.5
120
21
70
2010 CA08103002Z-EN
24.5
a
www.eaton.com
70
93
108
7.5
Small enclosures, basic enclosures 20/103
Small enclosures
CI-K…, CI-B. CI-C, CI-D
Small insulated material enclosures
Small enclosures
Part no.
CI-K4-125-...
CI-K4-160-...
30
23
CI-K4-...
74
a
125
160
b
72.5
107.5
Mounting plates
Mounting rails
M-CI-K4
TS-CI-K4
7.5
5.6
143.8
35
27
5.2
7.5
128
193
80
154
240
194
143
5.3
90
72.5
72
125
142
CI-K5-...
50.5
91
a
125
160
Mounting rails
M-CI-K5
TS-CI-K5
b
51.5
85.5
35
33.5
Part no.
CI-K5-125-...
CI-K5-160-...
Mounting plates
183
52.5
160
5.2
7.5
5
1.5
154
7.5
168
27
183
5.6
5.3
233
181
110
280
1.5
234
170
5
b
73.5
87
a
200
182
Basic enclosures
CI-B, CI-C, CI-D
4,5
12
c
c1
c2
b3
a
87
110
110
a1
71
95
97
b
149
165
222
b1
106
122
179
b2
128
144
201
b3
10.5
10.5
10.5
c
128
128
128
c1
115
115
115
c2
84.4
84.4
84.4
b2
b
b2
b1
M4
Part no.
CI-B
CI-C
CI-D
a1
a
2010 CA08103002Z-EN
www.eaton.com