HandPunch - Configuration of IP Address at Clock

HandPunch Initial Setup & IP Address Setup Instructions
Before you start: How to Setup & Install clock
•
•
•
•
•
Install clock so bottom of clock is 40 inches above the ground at waist height
Connect CAT-5 cable from clock’s RJ-45 network port & connect other end to DSL Modem
Plug in reader to standard power outlet (110/120 Volts), 4 ft cable provided (Don't hard wire)
Program Static IP Address, Subnet Mask & Default Gateway into clock (See below instructions)
Activate clock by calling Support at Ph# 718-784-4900
Set IP Address
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
To get entry to password level Press: Clear and Enter
Enter your Supervisor ID, followed by the Enter key: XXX then Enter
Place your hand for verification
Enter password followed by # key: 2#
Press (*) to skip set language
Press (*) to skip set date format
Press (*) to skip set date and time
Press (*) to skip set address
Press (*) to skip set id length
Set Serial: Press #
Verify/Enter IP Address (make sure to use all 3 numbers in each octet)
Example: 192.168.001.105
Verify/Enter Gateway (make sure to use all 3 numbers in each octet)
Example: 192.168.001.001
Verify/Enter Host Bit
9600 Baud: Press #
Clock Activation Instructions:
Once the clock is installed with the proper Static IP Address info configured in the clock
and the CAT-5 network patch cable is connected from the clock to DSL Modem
please give Central Time Clock a call at Ph# 718-784-4900 and ask for HandPunch
support to test communication. Once the clock is activated you will be able to start
enrolling new users and begin punching.
Call (718) 784-4900
www.centraltimeclock.com