Speaker`s module ELITE with 1 call button and RFID key/card reader

Speaker's module ELITE with 1 call
button and RFID key/card reader
ref. no. 6025/PR1-RF
Speaker's module ELITE with 2 call
buttons and RFID key/card reader
ref. no. 6025/PR2-RF
Speaker's module ELITE with 3 call
buttons and RFID key/card reader
ref. no. 6025/PR3-RF
Version I, 23.02.2017
SPEAKER’S MODULE REF. NO. 6025/PR1..3-RF
GENERAL INFORMATIONS / PROGRAMMING
SPEAKER’S MODULE REF. NO. 6025/PR1-RF,
6025/PR2-RF, 6025/PR3-RF
DANE TECHNICZNE
Power supply:
12V AC
Working temperature:
-20C  +45C
Dimensions with
nr. ref 6025/OND-M
157 x 67 x 23 [mm] (without visor)
157 x 67 x 35 [mm] (with visor)
Dimensions with
176 x 87 x 23 [mm]
nr. ref 6025/ RP-OP-M
Level of security
IK 07
Weight:
0,18 kg
Dimensions of info window: 30 mm x 70 mm
DIMENSIONS OF CASING
Surface-mounted housing ref. no. 6025/OND-M
GENERAL INFORMATIONS
Speaker's plate is made of stainless steel, vandal-proof degree of
protection IK07. Its compact size makes it ideal for mounting on
narrow pillars fence. Additional protection is a patent bolt securing
the front panel. Speaker’s module have 1, 2 or 3 call buttons and
the control module based access RFID technology. It supports keyrings and standard RFID cards UNIQUE 125 kHz, eg. Ref. no.
1052 / KZ or ISO CARD..
Infor window is highlighted in white flyover made in LED technology.
The brightness of the backlight is adjustable. At the time of
application programmed before a key fob or card information
window backlight turns green and operates the relay. Relay can run
eg. Open the gate. The module has configurable audible signal
(buzzer). The signaling can be turned off entirely, or set to one of
three levels of volume.
Module can connect an external button that will cause the behavior
of the module in such a way as during application of the
programmed key - so-called “opening button”.
You can configure the module settings, add, delete and edit keys
through software on the PC.
Flush-mounted housing ref. no. 6025/RP-OP-M
Speaker’s module can be mounted in two versions:
• surface-mounted – have to applied housing
Ref. no. 6025 / OND-M.
• flush have to applied frame Ref. no. 6025 / RP-OP-M. This is a
version without the visor. Very well masks any unevenness hole
prepared for the panel.
Speaker’s modules ref. no. 6025 / PR1-RF, 6025 / PR2-RF,
6025 / PR3-RF co-operate with the following types of power
supplies:
- Version classical: 18A2, 18L1;
- Version witch intercom: 19A2, 19L1.
OPIS ZŁĄCZ I ZACISKÓW POD PRZEWODY
441 "plus" microphone amplifier,
MK "minus" microphone amplifier,
GL, GL loudspeaker panel
AC, AC power panel
G GND key generator call signal,
G1 terminal of the first call button uniphone
G2 terminal of the second call button uniphone
G3 terminal of the third call button uniphone
COM relay common.
NO relay normally open.
PH terminal opening button (on closure of the MK).
2
SPEAKER’S MODULE REF. NO. 6025/PR1..3-RF
GENERAL INFORMATIONS / PROGRAMMING
PROGRAMING USING „PROG” BUTTON
This module is used for eg. in analog systems. The keys are stored
in the internal memory of the device. After applying the previously
stored key/card module change the highlight color from white to
green and the relay is “on” for the time specified by the user. In the
module can be program maximum 2000 keys.
To enter the menu system select one of two ways:
• hold PROG button for at least 1 second.
• applying to the RFID reader pre-programmed (in the 6-step of the
menu system) “MASTER” key.
Then the green LED next to the button PROG starts flashing and
steady light every few seconds. LED will flash together with the LED
module of the information contained in the front. The blinking green
LED signals a definite step in the menu system.
Changing step programming menu:
• short (less than 1 second) pressing PROG
• “MASTER” key application.
In RFID module are seven steps of programming.
To exit the menu system is possible at any time:
• hold PROG for at least 3 seconds.
• Apply the MASTER key after the seventh programming steps.
Automatic exit from the menu system will take place after
60 sec. if there has been no response from the user.
With PC application, you can enable / disable the option to enter the
Programming Menu PROG button.
ADDING A NEW KEY/CARD
The LED flashes cyclically 1 time.
After affixing the key to the reader follows his reading (signaled by
illumination of green LEDs and red LEDs light turns off), and then
save it to a memory. In the case of an erroneous entry key will be
blinking red LEDs. Flashing red LEDs may be one of three states:
• key is already stored in memory,
• there was an error reading key
• reader's memory is full.
.
REMOVAL SINGLE KEY/CARD
ADJUSTING THE TIME OF SWITCHING
RELAY
The LED flashes cyclically 5 times.
The default time of the relay is 1 sec. Each application key to the
reader extends the time that the relay by 1 sec. Touchdown key is
signaled by momentary lighting up of green LEDs. The maximum
duration of the relay is 20 seconds.
ADDING „MASTER” KEY / INSTALLER
PASSWORD
The LED flashes cyclically 6 times.
In this step, you can add the so-called “MASTER” key. Applying the
key to the reader will save the key as the MASTER key. Only one
key can be the key to MASTER. This key can be configured module
ref. 5025 / ZK-RF without unscrewing it and pressing the button
PROG. More action MASTER key is in the "PROGRAMMING IN
STAND-ALONE MODE USING "MASTER" KEY”.
BUZZER VOLUME
The LED blinks cyclically 7 times.
In this step, you can change the volume of the buzzer. Applying the
key to the reader will change the volume of the buzzer. Last played
the buzzer volume is stored. To turn off the buzzer, remove the
jumper BU.
PROGRAMMING USING "MASTER" KEY
Application to RFID key/card reader will enter the programming
mode. While working in programming mode any another application
of MASTER key will change the programming step. After going
through the whole cycle of programming menu (7 steps) will exit the
programming menu. Active step programming menu flashing LEDs
indicate information module. Only in the fourth step of the
programming mode - "Adjusting brightness of the backlight" LEDs
do not blink.
In this mode, affixing its stored key to the reader will light up green
LEDs while extinguishing the red LEDs and remove it from the
memory. Flashes red LED indicates that the key was not found
written in the memory, or there is an incorrect reading.
Warning:
Changing the settings for each step programming menu, make
different key than the MASTER key.
MASTER key will not turn on the relay as normal key. Record
Setting the backlight brightness, buzzer volume and time of the
relay takes place only after exiting the programming mode.
Adding and deleting keys takes place while application to the
module.
REMOVAL ALL KEYS/CARDS
OPENING BUTTON PH
The LED flashes cyclically 3 times.
RFID key/card reader can connect an external opening button. It
should be connected into terminals “PH” and “- / ~”. Button will turn
on the relay the same as application programmed key to the reader.
The LED flashes cyclically 2 times.
In this mode, followed by the removal of all keys stored in the
reader's memory. Quadruple application to the reader any key
(stored by the reader or not) will be deleted with the memory of all
stored keys.
ADJUSTING BRITHNESS OF THE
BACKLIGHT
JUMPER BU
The jumper is used to enable / disable the buzzer. Founded jumper
activates the buzzer. Removed the jumper off the buzzer.
POWER
The LED flashes cyclically 4 times.
Speaker’s module must be supplied with AC voltage 12VAC.
In this step, applying to the reader any key will increase the
brightness of the backlight for 5 levels of brightness. Increasing the
brightness occurs at intervals of 0.5 seconds. Once the maximum
brightness level drops to its minimum value, and the whole cycle
repeats itself.
3
SPEAKER’S MODULE REF. NO. 6025/PR1..3-RF
MONTAGE
PANEL MONTAGE
INSERTING THE LABEL TO INFO WINDOW
To attach the label information have to:
1. Unscrew with the included wrench the screw that secures
the front panel.
2. Remove the lower screw fastening motherboard.
4.
5.
In the slot in the faceplate Plexiglas insert the correct
label.
Tighten the screw that secures the motherboard.
In the original packaging is one additional label.
You
can
download
from
the
website
http://urmet.com.pl/INSTRUKCJE/6025_PRx_RFID
_FORMATKA.pdf
template
labels
printable
version.
3.
PHOTO NO. 1
Remove the label
PHOTO NO. 2
4
SPEAKER’S MODULE REF. NO. 6025/PR1..3-RF
MONTAGE
SURFACE MOUNTING
To install the panel surface-mounted version follow the steps below.
FLUSH MOUNTING
1. Loosen the screw with a key patent secures the front panel.
2. Pass the cable through one of the openings in the rear part B of
the box (housing) (Photo below).
3. Screw the box to the ground using the holes A located in the
back of the box (Photo below).
4. Connect the wires to the appropriate terminals speaker’s module
according to the wiring diagram.
5. Close and fasten the faceplate panel.
To mount the panel-mounted version follow the steps below.
1. Loosen the screw with a key patent secures the front panel.
Remove the face plate.
2. Insert the wires connecting using one B of the holes in the back
of housing (Photo below).
3. Place housing in the wall (hole).
4. Screw housing to the ground using the holes A.
5. Connect the wires to the appropriate terminals speaker’s module
according to the wiring diagram.
6. Close and screw on the front panel of the module.
5
WIRING DIAGRAM
WITH POWER SUPPLY 18A2 AND SPEAKER’S MODULE 6025/PR1-RF
6
WIRING DIAGRAM
WITH POWER SUPPLY 18L1 AND SPEAKER’S MODULE 6025/PR2-RF
7
WIRING DIAGRAM
WITH POWER SUPPLY 19A2 AND SPEAKER’S MODULE 6025/PR2-RF
8
WIRING DIAGRAM
WITH POWER SUPPLY 19L1 AND SPEAKER’S MODULE 6025/PR2-RF
9
NOTES
10
NOTES
11
MIWI-URMET Co. Ltd.
Pojezierska 90A
90-341 Lodz, Poland
tel: 004842 616 21 00
fax: 004842 616 21 13
e-mail: miwi@miwiurmet.pl
http:/www.miwiurmet.pl
The symbol of the crossed out wheeled bin indicates that the product (electrical and electronic equipment) should not be placed in municipal
waste. Please check local regulations for disposal of electronic products.
Download PDF