FLP-MXC-4+4 - Flepcher specializes in manufacturing of Prossional

Portable Sound System
FLP-MXC-4+4
Pre-amplifier
Mixer Amp/ Pre Amp/ Power Amp
The MXC-4+4 mixer is designed to support a smooth interconnection with external recorder in a PA system. With 6 MIC
inputs, 4 auxiliary inputs and 1 REC output, this unit has everything a system requires. To promote a higher usability of
application, the MXC-4+4 incorporates the +48V Switch Select phantom-power configuration, which caters up to 4
balanced XLR MIC inputs and a priority microphone broadcast.
Built to cater various application, the MXC-4+4 is user-friendly and highly adaptive to difference types of deployments.
Features such as individual microphone gain with bass and treble control provides ease of control and flexibility.
With a ubiquitous black metal finish, the physical unit boosts a strong practical design, giving users a taste of durability and
understated style.
Product Features
• Individual gain controls for MIC
• Master volume control
• Four-way audio source selection
• Power level indicator
• Priority microphone broadcasting
• Bass and treble tone controls
• 24V DC back-up power supply interface
Paging Microphone
& Zone selector
Specifications
Features
4 Mono and 4 Stereo Pre-Amplifier
Input
6 Microphones and 4 Auxiliary Input
Main and REC
Output
Power Supply
230V AC 50/60Hz, 24VDC
Dimension (W x D x H)
484mm X 370mm X 88mm
7.8 kg
Weight
Mic 1-4
input
Line 1-4
input
Output to
power
amplifier
Rack mount equipment
DC 24V
input
Mic 5-6
Input
11
TM
PROFESSIONAL PUBLIC ADDRESS SYSTEM
MIXER PRE-AMPLIFIER
FLP-MXC4+4
MIXER PRE-AMPLIFIER
OUTPUT LEVEL
LINE
4
5
6
4
3
7
1
9
8
2
0
10
MIC 1
5
6
4
3
7
1
9
8
2
0
10
MIC 2
5
6
4
3
7
1
9
8
2
0
10
MIC 3
5
6
7
1
9
8
10
MIC 4
CD
4
3
2
0
TUNER
5
0
6
3
7
1
9
0
4
10
MUSIC
5
6
3
8
2
0
POWER
TAPE
7
8
2
-12
+12
BASS
-12
+12
TREBLE
ON
OFF
9
1
0
10
MASTER
FLP-MXC4+4
OPERATION MANUAL
Please follow the instructions in this manual to obtain the optimum results from this unit.
We also recommend that you keep this manual handy for future reference.
TABLE OF CONTENTS
1. SAFETY PRECAUTIONS .......................................................................................3
2. GENERAL DESCRIPTION ....................................................................................5
3. FEATURES ...............................................................................................................5
4. NOMENCLATURE AND FUNCTIONS
4.1 Front Panel .............................................................................................................6
4.2 Rear Panel..............................................................................................................7
5. CONNECTIONS....................................................................................................... 8
6. APPLICATIONS ...................................................................................................... 9
7.SPECIFICATIONS .................................................................................................10
8.DIMENSIONAL DIAGRAM ................................................................................... 11
FLP-MXC4+4
2
1. SAFETY PRECAUTIONS
Be sure to read the instructions in this section carefully before use.
Make sure to observe the instructions in this manual as the conventions of safety symbols and messages
regarded as very important precautions are included.
We also recommend you keep this instruction manual handy for future reference.
Safety Symbol and Message Conventions
Safety symbols and messages described below are used in this manual to prevent bodily injury and property
damage which could result from mishandling. Before operating your product, read this manual first and
understand the safety symbols and messages so you are thoroughly aware of the potential safety
Indicates a potentially hazardous situation which, if mishandled, could
result in death or serious personal injury.
Indicates a potentially hazardous situation which, if mishandled, could
result in moderate or minor personal injury, and/or property damage.
When Installing the Unit
Do not expose the unit to rain or an environment
where it may be splashed by water or other liquids,
as doing so may result in fire or electric shock.
Use the unit only with the voltage specified on the
unit. Using a voltage higher than that which is
specified may result in fire or electric shock.
Do not cut, kink, otherwise damage nor modify the
power supply cord. In addition, avoid using the
power cord in close proximity to heaters, and never
place heavy objects -- including the unit itself -- on
the power cord, as doing so may result in fire or
electric shock.
Be sure to replace the unit's terminal cover after
connection completion. Because high voltage is
applied to the speaker terminals, never touch these
terminals to avoid electric shock.
Be sure to ground to the safety ground (earth)
terminal to avoid electric shock. Never ground to a
gas pipe as a catastrophic disaster may result.
Avoid installing or mounting the unit in unstable
locations, such as on a rickety table or a slanted
surface. Doing so may result in the unit falling
down, causing personal injury and/or property
damage.
3
FLP-MXC4+4
When the Unit is in Use
Should the following irregularity be found during
use, immediately switch off the power, disconnect
the power supply plug from the AC outlet and
contact your nearest FLEPCHER dealer. Make
no further attempt to operate the unit in this condition
as this may cause fire or electric shock.
If you detect smoke or a strange smell coming
from the unit.
If water or any metallic object gets into the unit
If the unit falls, or the unit case breaks
If the power supply cord is damaged (exposure of
the core, disconnection, etc.)
If it is malfunctioning (no tone sounds.)
To prevent a fire or electric shock, never open nor
remove the unit case as there are high voltage
components inside the unit. Refer all servicing to
your nearest FLEPCHER dealer.
Do not place cups, bowls, or other containers of
liquid or metallic objects on top of the unit. If they
accidentally spill into the unit, this may cause a fire
or electric shock.
Do not insert nor drop metallic objects or
flammable materials in the ventilation slots of the
unit's cover, as this may result in fire or electric
shock.
1. SAFETY PRECAUTIONS
When Installing the Unit
Never plug in nor remove the power supply plug
with wet hands, as doing so may cause electric
shock.
When unplugging the power supply cord, be sure
to grasp the power supply plug; never pull on the
cord itself. Operating the unit with a damaged
power supply cord may cause a fire or electric
shock.
When moving the unit, be sure to remove its power
supply cord from the wall outlet. Moving the unit
with the power cord connected to the outlet may
cause damage to the power cord, resulting in fire or
electric shock. When removing the power cord, be
sure to hold its plug to pull.
Do not block the ventilation slots in the unit's cover.
Doing so may cause heat to build up inside the unit
and result in fire.
Avoid installing the unit in humid or dusty locations,
in locations exposed to the direct sunlight, near the
heaters, or in locations generating sooty smoke or
steam as doing otherwise may result in fire or
electric shock.
When the Unit is in Use
Do not place heavy objects on the unit as this may
cause it to fall or break which may result in
personal injury and/or property damage. In
addition, the object itself may fall off and cause
injury and/or damage.
Make sure that the volume control is set to
minimum position before power is switched on.
Loud noise produced at high volume when power is
switched on can impair hearing.
Do not operate the unit for an extended period of
time with the sound distorting. This is an indication
of a malfunction, which in turn can cause heat to
generate and result in a fire.
Contact your FLEPCHER dealer as to the cleaning.
If dust is allowed to accumulate in the unit over
a long period of time, a fire or damage to the unit
may result.
If dust accumulates on the power supply plug or in
the wall AC outlet, a fire may result. Clean it
periodically. In addition, insert the plug in the wall
outlet securely.
Switch off the power, and unplug the power supply
plug from the AC outlet for safety purposes when
cleaning or leaving the unit unused for 10 days or
more. Doing otherwise may cause a fire or electric
shock.
An all-pole mains switch with a contact separation of at least 3 mm in each pole shall be incorporated in
the electrical installation of the building.
FLP-MXC4+4
4
2. GENERAL DESCRIPTION
FLEPCHER series of public address mixer amplifiers have power ratings 20W watts RMS, these
sleek, attractive units provide a compact solution for PA system amplification and distribution.
3. FEATURES
=Four MIC input
=Individual gain controls for IMC .
=Master volume control.
=Bass and treble tone controls .
=24V DC interface.
=4 balanced XLR mic input with selectable priority and each with phantom power.
5
FLP-MXC4+4
4. NOMENCLATURE AND FUNCTIONS
4.1 FRONT PANEL
12 11 10
9
8
FLP-MXC4+4
TM
MIXER PRE-AMPLIFIER
OUTPUT LEVEL
LINE
4
5
6
3
4
7
8
2
9
1
0
10
MIC 1
5
6
3
4
8
0
6
8
9
1
0
10
MIC 2
4
7
2
9
1
5
3
7
2
10
MIC 3
5
6
3
4
7
8
2
9
1
0
TUNER
10
MIC 4
CD
5
0
6
3
0
4
8
0
10
6
7
8
2
9
1
5
3
7
2
+12
-12
+12
0
10
BASS
TREBLE
MASTER
2
3
4
5
1. MIC1 \ MIC2 \ MIC3 \ MIC4
MIC volume control (MIC1/MIC2/MIC3/MIC4)
2. MUSIC
Music volume control
3. BASS
Adjust bass response. Rotate clockwise to increase
bass output and anticlockwise to reduce it.
4. TREBLE
Adjust treble response. Rotate clockwise to increase
treble output and anticlockwise to reduce it.
5. MASTER
Master volume control
6. POWER SWITCH
On top of the opening Power
Press the end, power shut down
ON
OFF
9
1
-12
MUSIC
1
POWER
TAPE
6
7
7. POWER
Power indicator
8. OUTPUT LEVEL
Power level indicator
9. TAPE
Select tape channel input keyswitch
10. CD
Select CD channel input keyswitch
11. TUNER
Select tuner channel input keyswitch
12. LINE
Select line channel input keyswitch
FLP-MXC4+4
6
NOMENCLATURE AND FUCTIONS
4.2 REAR PANEL
23
22
2
1
3
MIC 5
XLR BAL
1-GND
2-HOT+
3-COLD-
2
1
3
PHANTOM
MIC
PHANTOM
MIC 1
2
1
PHANTOM
MIC
PHANTOM
MIC
BATT SUPPLY
2A
24V
1
2
3
GAIN
MIC 3
MIC 2
2
3
13
MIC
VOLUME
TAPE
~240V 50Hz
T0.5AL 250V
TUNER
LINE
REC
MIC 6
1
2
3
GAIN
GAIN
OUT
MIC 4
2
1
3
GAIN
CD
1
3
GAIN
VOLUME
14
15
13. 24V DC BATT SUPPLY
14. MIC(1~4)
MICRO(1~4)microphone input
15. GAIN
MICRO(1~4) microphone gain control
16. LINE
Audio source interface
17. REC
To recorder interface
18. OUT
Balanced Audio output
16
17 18 19
GAIN
20
19. MIC(5~6)
MICRO(5~6) microphone volume control
20. MIC(5~6)
MICRO(5~6)microphone input
21. GAIN
MICRO(5~6) microphone gain control
22. PHANTOM POWER
MIC(1~4) phantom power select switch
23. ~240V/50Hz AC power input
NOTE:
Mute function:MIC1 has the mute function to MIC2~4,MIC5~6,all the line input;
MIC2~4 has the mute funtion to MIC5~6,all the line input;
MIC5-6 and all of the line input at the same level;
7
FLP-MXC4+4
21
5. CONNECTIONS
XLR CONNECTIONS
1. INPUT CONNECTION XLR
1 = GN D
2 = HO T
3 = CO LD
2. INPUT CONNECTION RCA
HOT right
GND
HOT left
GND
FLP-MXC4+4
8
9
FLP-MXC4+4
DC 24V
BATT SUPPLY
2A
24V
~240V 50Hz
T0.5AL 250V
MIC 1
2
3
PHANTOM
GAIN
3
GAIN
2
3
PHANTOM
MIC 3
1
MIC 2
MIC
GAIN
2
3
PHANTOM
MIC 4
1
MIC 3
MIC
1
GAIN
MIC 4
MIC
CASSETTE EQUIPMENTS
2
PHANTOM
MIC 2
1
MIC 1
MIC
TAPE
3
1
CD
2
TUNER
XLR BAL
1-GND
2-HOT+
3-COLD-
LINE
REC
ADRESS TAG
ADDRESS TAG
VOLUME
VOLUME
2
3
3
1
1
GAIN
MIC 6
GAIN
MIC 5
LINK
COM
COM
L
R
FM 75
AUDIO
OUT
GND
AM
ANTENNA
LOOP ANTENNA
RECORDER EQUIPMENTS
OUT
2
INPUTS
3
1
1
3
2
OUTPUTS
MIC 5
XLR BAL
1-GND
2-HOT+
3-COLD
L
R
AUDIO
OUT
L
R
~240V 50Hz
T1AL 250V
CD PLAYER
~240V 50Hz
T1AL 250V
AM/FM TUNER
MIC 6
2
INPUTS
POWER AMPLIFIER
6. APPLICATIONS
REAR PANEL CONNECTIONS
7. SPECIFICATIONS
MIXER AMPLIFIER
MODEL
4 MICROPHONE INPUTS
SENSITIVITY
FLP-MXC4+4
XLR Balanced with phantom power
-50 /-2dB,2.5mV / 500 mV
SIGNAL TO NOISE RATIO
>68 dB
FREQUENCY RESPONSE
40 / 17.000 Hz (-3 dB)
PHANTOM POWER
+48 V
4 AUXILIARY INPUTS
TUNER AND TAPE INP UTS
SENSIVITY/IMPEDANCE
CD AND LINE INPUTS
SENSIVITY/IMPEDANCE
SIGNAL TO NOISE RATIO
90 dB
FREQUENCY RESPONSE
40/20.000Hz (-3 dB)
CONTROL
BASS
+12 dB
TREBLE
+12 dB
OUTPUTS
POWER CONSUMPTION
20W
OUTPUT ELECTRO/IMPEDANCE
OUTPUT REC/IMPEDANCE
DISTORTION
< 1%
OPERATING CONDITION
AC MAINS INPUT
DIMENSIONS (D X W X H)mm
WEIGHT
240V A C 50Hz, 24V DC(optional)
484X370X88
4.5Kg
FLP-MXC4+4
10
8. DIMENSIONAL DIAGRAM
UNIT:mm
484
FLP-MXC4+4
TM
MIXER PRE-AMPLIFIER
6
3
4
8
0
8
0
6
3
7
8
0
TUNER
6
3
7
4
8
0
0
0
4
8
0
5
6
3
7
7
8
2
9
1
10
MIC 4
POWER
TAPE
6
2
9
1
10
MIC 3
CD
5
3
7
2
9
1
10
MIC 2
5
4
2
9
1
10
MIC 1
5
4
2
9
1
6
3
7
2
5
-12
+12
BASS
0
+12
TREBLE
ON
OFF
9
1
-12
10
MUSIC
94
5
88
OUTPUT LEVEL
LINE
4
10
MASTER
436
2
MIC 5
XLR BAL
1-GND
2-HOT+
3-COLD-
1
3
2
1
3
MIC
PHANTOM
PHANTOM
MIC
PHANTOM
MIC
VOLUME
TAPE
~240V 50Hz
T0.5AL 250V
MIC 1
2
1
3
MIC 3
MIC 2
2
1
2
TUNER
CD
LINE
REC
MIC 6
1
2
3
3
GAIN
GAIN
OUT
MIC 4
2
1
3
GAIN
BATT SUPPLY
24V
MIC
84
PHANTOM
1
3
GAIN
GAIN
VOLUME
2A
GAIN
339
333
84
25
6
Over 100
UNIT:mm
FLP-MXC4+4
TM
MIXER PRE-AMPLIFIER
OUTPUT LEVEL
LINE
4
5
6
3
4
7
8
2
9
1
0
10
MIC 1
5
FLP-MXC4+4
4
7
8
2
9
1
0
10
MIC 2
Over 100
11
6
3
5
6
3
4
7
8
2
9
1
0
10
MIC 3
5
4
7
8
2
9
1
0
TUNER
6
3
10
MIC 4
CD
5
0
0
4
8
0
10
MUSIC
6
7
8
2
9
1
5
3
7
2
POWER
TAPE
6
3
9
1
-12
+12
BASS
-12
+12
TREBLE
ON
OFF
0
10
MASTER
Over 100
TM
2012-05
Version0.1
Download PDF