user guide

MA00029
ORDER NO.:
50650
50660
50670
50680
BRUSHLESS
MAINTENANCE FREE
SENSORED TECHNOLOGY
1-STAR
2-STAR
3-STAR
4-STAR
USER GUIDE
Dear Customer,
thank you for your trust in this LRP product. By purchasing a LRP VECTOR Brushless Modifi ed motor, you have
chosen a high-performance brushless motor full of new design features, such as:
• Sensored technology
• Neodymium magnets
• Adjustable timing
• Handwound
• Standard 540 size/weight
• VTEC X9/X10 teardown, dismountable
Please read the following instructions to ensure, that your LRP VECTOR Brushless Modifi ed motor always works
up to your full satisfaction.
Please read and understand these instructions completely before you use this product!
With operating this product, you accept the LRP warranty terms.
LRP electronic GmbH
Wilhelm-Enssle-Str. 132-134, 73630 Remshalden, Germany
Tel.: int+49-7181-4098-0, Fax: int+49-7181-4098-30
INFO@LRP-ELECTRONIC.DE WWW.LRP-ELECTRONIC.DE
SPECIFICATION
VECTOR 4-Star VECTOR 3-Star
! WARNING NOTES
IMPORTANT: Pay close attention to the following points, as they will destroy the motor and void your warranty:
• Never solder a Schottky diode to the motor or the speed-control when you are using a LRP VECTOR Brushless
Modifi ed motor.
• Avoid soldering longer then 5sec per soldering joint when replacing the power wires to prevent possible
damage to the motor due to overheating of the components!
RPM
Kv
Power
Effi ciency
Ball Bearings
Teardown
61.200
8.500 rpm/Volt
283W
91%
2 x R166ZZ
VTEC X10 dismountable
Timing
Winding
Hall-Sensor pin assignment
55.440
7.700 rpm/Volt
263W
92%
VECTOR 2-Star
VECTOR 1-Star
49.680
6.900 rpm/Volt
242W
92%
2 x R2ZZ
43.920
6.100 rpm/Volt
220W
93%
VTEC X9 - dismountable
adjustable
Star
compliant to IFMAR/EFRA/ROAR/BRCA/DMC rules
Meassured at 7,2V. Specifi cations subject to change without notice.
• Never connect the motor incorrectly or with reversed polarity.
• All wires and connections have to be well insulated. Short-circuits can destroy the motor.
• Avoid overtightening the motor screws. Damaged threads are not covered by warranty!
TIMING
• Install the motor in the model.
CAUTION! The maximum length of the
motor screws shall not exceed 8mm.
• Connect the motor and the speed-control,
using the Hall-Sensor wire.
C
+
B
blue
yellow
orange
INSTALLATION / CONNECTIONS
-A
• Connect the power wires of the speedcontrol to the motor. You can do this by
using the pre-assembled motor plugs or
by soldering on the power wires directly
to the motor.
• CAUTION! Make sure, that the polarity is
C
B
A
With the LRP VECTOR Brushless Modifi ed motor, you have the possibility to change the timing. The factory
setting is position 2. You can easily see this by checking the mark on the plastic ring and the corresponding
timing scale on the motor can. This setting is the best compromise between performance, runtime and torque.
By altering the timing, you change the characteristics of the motor. With a higher timing, the motor revs higher,
but has less torque. We recommend to use the factory setting. It is the best for most applications.
Please note: You need to use a shorter gearing, when using a higher timing. When using a LRP SPHERE COMPETITION speedo with ADPC profi les 3-6, the timing of the motor has to be set to 2.
To change the timing, do the following:
1. Loosen the 3 screws on the backplate of the motor.
2. Turn the plastic ring with the timimg mark to the desired timing position. You can use a small screwdriver
to turn the plastic ring, if necessary.
Please note: To change the timing, you only need to turn the plastic ring with the timing mark. Do not try to
turn the whole backplate of the motor.
3. Re-tighten the 3 screws on the backplate of the motor again.
Hall-Sensor wire
right by checking the color code and the letters:
- MOT.A = blue wire
- MOT.B = yellow wire
- MOT.C = orange wire
• Finally check all the connections before using the motor.
HALL-SENSOR WIRE:
This bi-directional multipole wire connects the speed-control and the motor. Do not alter or modify this cable!
The Hall-Sensor wire is imminent for the use of the LRP VECTOR Brushless Modifi ed motor. Connect the motor
to the speed-control, by using this wire and make sure, that the plugs have a proper and tight fi t. There are
replaceable hall sensor wires available:
• #81910 (20cm)
• #81920 (10cm)
POWER WIRES:
The LRP VECTOR Brushless Modifi ed comes pre-wired using common motor connectors. It‘s simply „plug &
play“ when you intend using a LRP SPHERE speed-control. You can also use normal power wires (a complete
set of power wires is included with the LRP SPHERE and SPHERE COMPETITION) and solder them directly to the
motor if you prefer to use a „hardwired“ wire setup. The unique splitted solder-tabs allow easy and convenient
replacement of the power wires. Nevertheless some soldering skills are required. Talk to your local hobbyshop
if you are concerned about replacing the wires yourself.
There is a replacement power wire set available: #82505
CAUTION: Avoid soldering longer then 5sec per soldering joint when replacing the power wires to prevent
possible damage to the speed-control due to overheating of the components!
GEARING
DISASSEMBLY
Due to the maintenance free design of the LRP VECTOR Brushless Modifi ed motor, it is not necessary to open
the motor under normal conditions. Nevertheless, if you intend to check the ball bearings and oil them from time
to time, you can disassemble the motor.
Disassembling of the motor:
1. Remove the 3 screws at the front of the motor and take off the front cover. You can now take out the ball
bearing to clean it or, if necessary, to oil it.
2. Carefully take the magnet out of the can.
IMPORTANT! There are two spacers on the front and back of the shaft. They both have a different length.
Please be sure to use the right lenght spacer on the front and rear when putting the magnet back into the can.
This does not apply to the 4-Star motor. The motor already has fi xed spacers.
3. Remove the 3 screws from the back of the motor and take off the backplate. You can now take out the ball
bearing to clean it or, if necessary, to oil it.
4. To re-assemble the motor, begin with step 3. Double-check, that you use the right lenght spacers on the
magnet shaft and be sure to re-tighten alls screws securely.
VECTOR 4-Star
Never overgear your LRP VECTOR Brushless Modifi ed motor. A wrong gear-ratio causes much more heating and
may result in a temperature shutdown of your speed-control under extreme conditions.
Due to the unique VECTOR brushless design, this motor needs to be geared much lower then normal brushed
motors. Take your kits instruction manual to fi nd the correct pinion. The followong recommendations are a good
starting point but may vary due to different tracks, models and batteries:
4-star
3-Star
2-Star
1-Star
Touringcars 1:10
(small tracks)
10.5 : 1
9.4 : 1
8.6 : 1
7.8 : 1
Touringcars 1:10
(big tracks)
9.8 : 1
8.2 : 1
7.5 : 1
7.0 : 1
Off-Road
2WD
12.0 : 1
11.0 : 1
10.0 : 1
9.0 : 1
Timing setting 6
Timing setting 2
Off-Road
4WD
14.0 : 1
13.0 : 1
12.0 : 1
11.0 : 1
VECTOR 1-, 2-, and 3-Star
long
short
REPAIR PROCEDURES / LIMITED WARRANTY
All products from LRP electronic (hereinafter called “LRP”) are manufactured according to the highest quality
standards. LRP guarantees this product to be free from defects in materials or workmanship for 90 days from the
original date of purchase verifi ed by sales receipt. This limited warranty doesn’t cover defects, which are a result
of normal wear, misuse or improper maintenance.
To eliminate all other possibilities or improper handling, fi rst check all other components before you send in this product for repair or warranty. Products sent in for repair, that operate perfect have to be charged with a service fee.
By sending in this product, you assign LRP to repair the product, if it is no warranty case. The original sales receipt
including date of purchase needs to be included. Otherwise, no warranty can be granted. For quick repair- and
return service, add your address and detailed description of the malfunction.
Our limited warranty liability shall be limited to repairing the unit to our original specifi cations. In no case shall
our liability exceed the original cost of this unit. Because we don’t have control over the installation or use of this
product, we can‘t accept any liability for any damages resulting from using this product. By installing or operating
this product, the user accepts all resulting liability.
The specifi cations like weight, size and others should be seen as guide values. Due to ongoing technical improvements, which are done in the interest of the product, LRP does not take any responsibility for the accuracy of
these specs.
LRP-Distributor-Service:
• Package your product carefully and include sales receipt and detailed description of malfunction.
• Send parcel to your national LRP distributor.
• Distributor repairs or exchanges the product.
• Shipment back to you usually by COD (cash on delivery), but this is subject to your national LRP distributor‘s
general policy.
Download PDF