TruVision Box Camera Outdoor Housing with Heater (TVC-OH2

TruVision Box Camera Outdoor Housing
with Heater (TVC-OH2-H) and Wall Mount
(TVC-M2-WM) Installation Instructions
Dimensions
Internal Space:
Housing:
Accessories:
Camera base plate dimensions
P/N 1073110-EN • REV C • ISS 02FEB17
1/4
Screw A: 1/4 - 20 UNC × 10, 2 pcs
Used to attach the box camera to camera base plate.
Supported cameras
The housing can be used with the following box
cameras:
TVI/Analog Box
Camera
TVC-4401, TVC-2401
IP Box Camera
TVC-1201, TVC-3201, TVC-1202, TVC3202,
TVC-5401, TVC-5402, TVC-5403
Screw B: 1/4 – 20 UNC × 14, 2 pcs
Used to attach the TVC-OH2-H to the wall mount bracket
(TVC-M2-WM).
Installation
The housing is shipped with a TVC-M2-WM box
camera wall mount.
Dimensions of TVC-M2-WM:
297.3 × 88 × 122.9 mm (11.7 × 3.5 × 4.8 in.)
Weight of TVC-M2-WM:
2/4
To attach a box camera to the box camera
outdoor housing (TVC-OH2-H):
Note: Prior to installing the TVC-OH2-H housing, run
the interconnect cables and mount the wall bracket
(TVC-M2-WM). Refer to the TVC-M2-WM Wall
Mount Installation Instructions.
1.
Loosen the two latches located on the side of
the TVC-OH2-H to release the housing cover.
Lift the housing cover open.
2.
Loosen the four camera base plate screws and
remove the base plate from the camera
housing. Attach the box camera to the base
plate, using the two A screws.
473 g (1.04 lbs.)
P/N 1073110-EN • REV C • ISS 02FEB17
Note: You must install the appropriate
lens on the box camera before this step.
Please choose a lens with specifications
that are suitable for the application.
3.
Install the camera and base plate assembly in
the housing. Tighten the four screws to keep
the camera assembly firmly in place.
Terminals:
24 VAC output: Connect the camera
24 VAC input.
12 VDC: Connect the camera 12 VDC
power input. The positive/ negative
terminals should be distinguished.
4.
RS-485 Port: Reserved for wiper control
(the wiper feature is not supported in this
model)
Attach the housing to the TVC-M2-WM wall
mount bracket by using the two B screws.
Note: 24 VAC/4 A UL listed Class 2 or
CE certified power supply is required
(purchased separately) for the device to
function properly.
5.
Route the cables into the housing through the
cable gland.
Note: Please ensure that the power
supply is OFF during installation.
The fan and heater are prewired at the
factory.
7.
Connect the power and video coax cable
and/or Ethernet cable to the box camera.
Power a 12 VDC camera:
Heater
6.
Fan
Connect the power supply (purchased
separately) cable to the 24 VAC input
terminals on the terminal panel.
24 VAC input
1.
P/N 1073110-EN • REV C • ISS 02FEB17
Black 12 VDC-
2.
Red 12 VDC+
3/4
Specifications
Power a 24 VAC camera:
Heater
Dimensions (L × W × H)
Fan
445.3 × 169.2 × 110 mm
(17.5 × 6.7 × 4.3 in )
Weight
1900 g (4.2 lbs.)
Working temperature
-40 to +60 ℃ (-40 to +140 °F )
Temperature control
Heater on: 5 ℃ ±5 ℃, fan operating
for constant temperature;
Fan on: 40 °C ±5 ℃, for heat
dissipation
24 VAC camera power
supply
3.
24 VAC input
When you have completed connecting the
cables, power on the housing, adjust the lens
to zoom and focus.
Zoom
Power supply
24 VAC 4 A. Purchased separately.
Power consumption
40 W max.
Environmental rating
IP66
Legal and regulatory
information
Trademarks and
patents
Certification
Copyright
Focus
4.
4/4
Close the cover of the housing and fasten the
clamps to finish the installation.
The trade names used in this document may
be trademarks or registered trademarks of the
manufacturers or vendors of the respective
products.
© 2017 United Technologies Corporation. All
rights reserved. Interlogix is part of UTC
Climate, Controls & Security, a unit of United
Technologies Corporation.
Contact information
For contact information, see www.interlogix.com or
www.utcfssecurityproducts.eu.
P/N 1073110-EN • REV C • ISS 02FEB17