GSM modem Connections Keypad connections

www.intercomsonline.com
Call: 888-298-9489
Quick Start Guide
GSM modem Connections
Modem LED indicators
Power LED
GSM
modem
close
GSM LED
Searching
open
Network found
VCC
AC
AC
DETECT
GND
PB
GND
close
GSM
modem
open
CPU LED
Standby
Busy
N/O
COM
N/C
12-15v dc
Optional
input limit
switch
from gate
+
-
Output
to gate
or lock
Exit button
Note: Keep power cable shorter than 10 feet if possible.
Use heavy gauge power cable capable of 5 amps, not
alarm cable or CAT5 signal cable.
SIM card
Use At&T or T-Mobile GSM 2G/3G SIM card, either Pre-pay
or contract.
If SIM is purchased with a phone, it must be unlocked by
network provider before it can be used in another device.
Ensure pre-pay SIM cards have calling credit and test in a
phone first.
Programming
Programming is done by sending SMS messages to the phone
number of the SIM card in the device.
Keypad connections
OUT2 OUT1
Power in
egress
N/O
COM
N/C
N/O
COM
N/C
Step 1
Check reception by sending the
SMS as shown…
+ N/C
COM
N/O
K or A
DU out
(-)GND
Sense
O/P1 inhib
OUT3
For full description
of functions, see
the complete user
guide.
1-12
Poor
Tamper
N/C
INT Lock
The reply should be above 13 for
acceptable performance.
13-20
Medium
21-31
Good
Step 2
Connecting keypad & Modem to Gate controls
Intercom
GSM Cellular
controller
COM
Program the numbers you wish the intercom to dial when
the call button is pressed…
*12*1234#110987654321#
Keypad
N/O COM
N/O
Pass code
Data
Function code
Note: All programming
messages must begin with
the pass code string as
shown in red.
Up to 3 numbers can be programmed in the same SMS text
as shown below…
Common
Start
*12*1234#11tel.number1#12tel.number2#13tel.number3#
11 = first number, 12 = second number, 13 = third number.
Gate motor
controller
Step 3
Program the length of time phones will ring before the
intercom will call the next number…
*12*1234#52??# ?? = time in seconds (10-99, default=20)
Step 4a
Now program telephone numbers you wish to have
access to the property. Up to 100 users can call the
intercom to open the gates at no call cost..
Example: Add user 31 to have access code 5555 operating
relay 2….
2
First you must tell the unit which country it is operating
in. Every country has a country code. You can find your
country code on the internet. Some examples are given
below..
USA = 1, Canada = 1, UK = 44
0
2
Group 2
0
Add code
3
1
5
Location 31
5
5
5
Pin code 5555
#
Validate
Step 4 - Change relay times
?
?
0
or
-
9
9
9
9
0 = start / stop toggle mode (latching)
1-99999 = seconds momentary operation
51=relay1
52=relay2
53=relay3
Send the following SMS replacing ??? with your country
code..
1
9
#
Validate
*12*1234#71???#
Note: Relay 1 is operated by group 1 codes, relay 2 by group
2 codes and relay 3 by group 3 codes.
Step 4b
Step 5 – Exit programming mode
Now you are ready to add the telephone numbers as
follows…
*12*1234#72?????# (????? = telephone number)
To Exit programming mode, press..
Up to 3 numbers can be added together in a single SMS as
follows..
Basic User instructions for the intercom
*12*1234#72tel.number1#72tel.number2#72tel.number3#
Keypad Programming (for keypad models only)
ON when incorrect codes entered and outputs are locked out.
GREEN when output 1 activated.
RED when output 2 activated.
1
2
3
FAST FLASHING – Wrong code entered / error.
4
5
6
SLOW FLASHING - in normal standby mode.
7
8
9
ON in programming mode.
*
0
#
ON when relay 3 activated.
0
0
*
Pressing the call button
When the call button is pressed, the intercom will dial in
turn up to 2 programmed telephone numbers. If the user
answers the call, they can press usually to trigger the
modem relay, or # to latch it on, or button 1 to unlatch
again. Note: Once the relay is latched, it must be unlatched
before it can be triggered again.
To access the property using your cell phone, simply call the
intercom phone number. If the number is stored, then the
intercom will automatically open the gates and end the call.
Controlling gates by SMS
To trigger gates, send SMS *33*5678#
To latch gates, send SMS *34*5678#
To unlatch gates, send SMS *35*5678#
Step 1 – Enter programming mode
0
*
Dialling the intercom
Note, after power up, as a security precaution, the keypad
cannot be programmed for 60 seconds. Once this time
elapses, you may begin.
0
*
*
Using the keypad
Step 2 – Enter new ENGINEERS code
0
1
?
Location
?
?
?
To activate the keypad, simply enter the user code.
#
4-8 digit code
If you require advanced features, or need troubleshooting
assistance, please read the full installation manual which
accompanied the product.
Validate
Step 3 – Enter new user codes
1
0
10= relay 1 codes
(1000 available)
20= relay 2 codes
(100 available)
30= relay 3 codes
(100 available)
2
0
2= add code
5= delete code
0
0
?
Memory locations
000-999 for relay 1
001-100 for relay 2
001-100 for relay 3
?
?
?
Pin code 4-8 digits
#
Validate
www.intercomsonline.com
Call: 888-298-9489
Download PDF