Built-in power supply unit

DORMA
Installation Manual
Built-in power supply unit
Built-in power supply unit
1. General
Table
of Contents
information
Table of Contents
1. General information . . . . . . . . . . . . . . . . . . . . . . 4
1.1 Preface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
1.2 Correct use . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
1.3 Safety instructions and warnings . . . . . . . . . . . . 5
1.4 Further Sources of Information . . . . . . . . . . . . . 6
1.5 Disposal . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
1.6 Components supplied . . . . . . . . . . . . . . . . . . . . 6
2. Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
2.1 Opening the device . . . . . . . . . . . . . . . . . . . . . . 7
2.2 Installing the built-in power supply unit . . . . . . . 8
3. Connection terminals . . . . . . . . . . . . . . . . . . . . . 9
3.1 General Information . . . . . . . . . . . . . . . . . . . . . 9
EU Declaration of conformity . . . . . . . . . . . . . . . . . 11
4. Technical data . . . . . . . . . . . . . . . . . . . . . . . . . 12
3
Built-in power supply unit
1. General information
The information provided in this installation guide may be
modified without prior notification. All previous versions
cease to be valid with the publication of this installation
guide.
The information in this installation guide has been compiled
to the best of our knowledge and in good faith. DORMA
Time + Access GmbH accepts no liability for the correctness
or completeness of the information provided.
In particular, DORMA Time + Access GmbH cannot accept
liability for any consequential damage due to incorrect or
incomplete information.
Time + Access GmbH assumes no liability for the faultless
operation of the built-in power supply unit in non-system
environments.
Despite every effort to prevent mistakes, they can never
be completely avoided. Therefore, we would be grateful to
receive notification of any errors or omissions.
DORMA Time + Access GmbH accepts no liability for the
information included in this document being free of
protected third-party rights.
DORMA Time + Access GmbH does not provide any licences
to its own or to third party patents or other protected rights
with this document.
The recommendations for installation provided in this
manual are based on favourable basic conditions. DORMA
It is not permissible to print, reproduce or pass this manual, or parts thereof, to third parties, other than for your own use,
without the approval of DORMA Time + Access GmbH.
All rights reserved.
DORMA Time + Access GmbH
PO box 21 01 85
53156 Bonn
http://www.dorma-time-access.de
E-Mail info@dorma-time-access.de
© Copyright 2011 by DORMA Time + Access GmbH
Drawing no.: 1018G-104-B2
As at: 11/11 V1.30
4
Built-in power supply unit
1. General information
1.1 Preface
This installation manual is intended to assist you in
installing, connecting and commissioning the built-in power
supply unit.
1.2 Correct use
The built-in power supply unit is a safety transformer
complying with EN 61558-2-6. It allows the devices B6R
WM, B6L WM, LANRTC and the I/O-9/8 module to be
connected directly to the 230 V mains power supply.
The transformer may only be operated when it is built into
the intended devices.
Operation in damp or wet rooms or outdoors is not
permitted.
Any other use than that indicated is not permitted!
1.3 Safety instructions and warnings
This unit has been constructed and tested in accordance
with the relevant current technical regulations. It left the
factory in perfect condition in terms of safety and reliability.
To maintain this condition and to ensure risk-free operation,
the instructions and warnings given in this installation guide
must be observed by the user.
• The built-in power supply unit may only be used for the
purpose intended by the manufacturer.
• Fitting and installation may only be carried out by a
qualified electrician.
• Before opening the unit, always switch off the power
supply and check that it is inactive by measuring.
• During assembly, be careful to avoid any action that could
contravene the requirements in the applicable equipment
safety standards relevant to the device, as this could
render the device unsafe to use.
5
Built-in power supply unit
1. General information
1.4 Further Sources of Information
Allg
em
Inst eine
alla
tions
ric
htlin
Systemlösung
Systemübersicht
Sicherungstechnik
Zeitwirtschaft
Zeiterfassung
Funktionsweise
Mechatronik
Planner Manual
Examples of cross-system solutions
Fluchtweg & TMS
Funktionsweise
Innenbereich
ien
Gelände
Zutrittskontrolle
DO
RM
A
Außenhaut
General Installation Guidelines
Specifications for planning attendance recording and
access control systems with our wired components.
Funktionsweise
Further documents are available on request.
1.5 Disposal
The device was manufactured using recyclable materials and
components.
When disposing of the device and the packaging, please
ensure environmentally friendly recycling.
Gelände
Außenhaut
Systemlösung
Systemübersicht
Sicherungstechnik
Zeitwirtschaft
Zeiterfassung
Funktionsweise
Mechatronik
Fluchtweg & TMS
Funktionsweise
Innenbereich
Zutrittskontrolle
Funktionsweise
Information for EU Countries
European Directive 2002/96 EC applies to this device.
This means that this product must not be disposed of with
normal household waste. We, the manufacturer, will take
back our electric and electronic products and dispose of
them for you free of charge. Correct disposal of your old
equipment protects people and the environment from
possible harmful consequences.
1.6 Components supplied
A 1 x 230 VAC/18 VAC transformer
B 1 x installation guide
C 1 x “230 V” label
D 4 x Z3 x 8 PT screws
E 1 x cable (18 V connection)
A
B
C
230VAC
110mA
DORMA
Installation Manual
Built-in power supply unit
D
4x
D
6
E
Built-in power supply unit
2. Installation
2.1 Opening the device
The procedure is the same for all devices.
The appearance may differ slightly.
7
Built-in power supply unit
2. Installation
2.2 Installing the built-in power supply unit
The installation must be carried out before the
device is mounted on the wall. Devices that are
already mounted must be removed from the wall.
The built-in power supply unit is screwed to the underside
of the device using the 4 accompanying Z3 x 8 PT screws.
Because the name plate still shows the 24 V
voltage the 230 V label must also be attached.
It is to be affixed to the cable inlet side above
the cable inlet.
A
C
230VAC
110mA
23
110VA
0m C
A
D
4x
8
Built-in power supply unit
3. Connection terminals
3.1 Allgemein
To make the connection, connect the phase
and the neutral wire directly to the power
supply unit. In the casing, the earth conductor must be connected to the screw labelled
with the earth conductor symbol.
B6R WM
The output voltage of the transformer is connected to the
ST311 terminal of the B6R WM using the supplied cable.
The device is designed for a permanent connection to the power supply circuit only.
It must be connected by a qualified electrician only.
The power supply circuit for this device
requires a suitable, easily accessible power
isolating device with a minimum contact
gap of 3 mm and a fuse element to protect
against short circuits, both already provided
on site.
230V~
18V~
The earth conductor must be connected.
18V~
9
3. Connection terminals
Built-in power supply unit
B6L WM/LANRTC
I/O-9/8 WM module
The output voltage of the transformer is connected to the
ST506 terminal of the B6L WM/LANRTC using the supplied
cable.
The output voltage of the transformer is connected to the
ST102 terminal using the supplied cable.
If the I/O 9/8 module is supplied with
alternating current (AC) it must not be used
for the power supply of sub-devices.
Sub-devices may only be supplied with
direct current (DC)!
230V~
18V~
18V~
230V~
LAN
24V
ST101
24V
ST102
18V~
18V~
OV
Power
ST506
9
OV
10
Built-in power supply unit
EG Konformitätserklärung
General information
EC 1.
Declaration
of Conformity
CE Déclaration de conformité
11
4. Technical data
Built-in power supply unit
Technischethe
Changing
Daten
protection classes
The protection classes according to EN 60950 change, as follows:
Device
without built-in power supply unit
with built-in power supply unit
B6R WM
Protection class III
Protection class I
B6L WM
Protection class III
Protection class I
LANRTC
Protection class III
Protection class I
I/O-9/8-Modul WM
Protection class III
Protection class I
Technical data
Primary voltage
230 VAC, 50...60 Hz
Secondary voltage
21 VAC/with no load
18 VAC/with nominal load
Output current
max. 1.33 A
Short-circuit and overload protection is present
Secondary output
24 VA
General design
Safety transformer according to EN 61558-2-6
The transformer may only be operated in the intended devices.
Ambient conditions
Temperature: -10 °C to +50 °C
Storage temperature range: -10 °C to +70 °C
Humidity range: 0 to 80%, non-condensing
Dimensions
(W x H x D) 57 x 68 x 35 mm
Weight
500g
We reserve the right to make technical modifications and improvements in the course of the further development our equipment.
DORMA Time + Access GmbH
PO box 21 01 85 • D-53156 Bonn • Mainzer Straße 36-52 • D-53179 Bonn
Tel. +49 (0) 2 28/85 54-0 • Fax +49 (0) 2 28/85 84-1 75 • www.dorma-time-access.de
DORMA GmbH + Co. KG
PO box 40 09 • D-58247 Ennepetal • DORMA Platz 1 • D-58256 Ennepetal
Tel. +49 (0) 23 33 / 793-0 • Fax +49 (0) 23 33 / 79 34 95 • www.dorma.com
12