Alpha Technologies' seismic rack is a modular two-post relay rack. The
rack has been Zone 4 rated and is NEBS L3 certified for up to 2500lb.
The bolt together design enables the rack to be flat packed, which
significantly simplifies the end user’s shipping and storage process.
The racks are available in various heights (3.5', 7', 7'6", 8' and 9').
Standard 19" or 23" mounting options enable customers to use the
racks for installing equipment and/or power systems. These racks can
be used with a wide variety of termination panels, battery accessories
and distribution options that help configure the optimal power system.
SEISMIC BOLTED STANDALONE RACKS
23" Seismic Rack, black
Part Number
Height
Dynamic Rating (GR63)
Static Rating
0300063-003
3.5'
500lb
1000lb
0300047-001
7'
1500lb
3000lb
0300047-002
7'
1000lb
2000lb
0300047-003
7'
500lb
1000lb
0300064-001
7'6"
1500lb
3000lb
0300065-001
8'
1500lb
3000lb
0300066-001
9'
1500lb
3000lb
19" Seismic Rack, black
Part Number
Height
Dynamic Rating (GR63)
Static Rating
0300062-001
7'
1500lb
3000lb
0300062-002
7'
1000lb
2000lb
0300062-003
7'
500lb
1000lb
NON-SEISMIC BOLTED STANDALONE RACKS
23" Non-Seismice Rack, black
Part Number
Height
Simulated Static Loading
030-510-20-123
7'
500lbs
19" Non-Seismice Rack, black
Part Number
Height
Simulated Static Loading
030-510-20-119
7'
500lbs
SEISMIC WELDED STANDALONE RACKS
23" Seismic Battery Rack, black*
Part Number
Height
Dynamic Rating (GR63)
0300163-001
7'
2500lb
*Welded rack which cannot be used in 'flat pack' applications
Figure 1 — Seismic rack front view
1
Seismic Rack General Installation Guide
ACCESSORIES
Mounting Kit
Part Number
Width
Description
0380042-021
NA
Seismic kit includes:
- seismic anchors and washers
5900708-001
NA
Rack joining bracket
(require 2 per rack)
5901537-001
30"
Extension base
(clips to the base front)
Part Number
Width
Description
0380063-001
23"
Includes insulation pad and bushings
0380108-001
19"
Includes insulation pad and bushings
Insulation Kit
Seismic Battery Tray (does not include breaker housing)
Part Number
Width
Description
0300061-003
23"
Fits most batteries (4 per tray)
19"
Designed for the following batteries (4 per tray):
• E xide/GNB Marathon M12V90FT
• C&D Technologies TEL 12-115 FNG
• East Penn 12AVR100-3ET
0300077-002
Breaker Housing, rack mount or left/right mount on battery tray
Part Number
Width
Description
0380128-001 (black)
NA
AM breakers, single-pole GJ
SEISMIC FLAT PACK RACKS
STEP 1: Select required zone 4 seismic rating of the rack
Part
Number
Dynamic
Loading (GR63)
Static
Loading
Description
0370117-001
1500lbs
3000lbs
1500lb, 7', 44RU Vertical rail kit
0370117-002
1000lbs
2000lbs
1000lb, 7', 44RU Vertical rail kit
0370117-003
500lbs
1000lbs
500lb, 7', 44RU Vertical rail kit
STEP 2: Select required width of the rack
Part Number
Width
Description
0370117-004
23"
23" Top and base kit
0370117-005
19"
19" Top and base kit
Flat Pack Assembly Instructions
Refer to 0370017-F0, at the end of the guide, for seismic flat pack rack assembly instructions.
2
Seismic Rack General Installation Guide
Mounting Details
Ø0.75 TYP
9.6
13.0
Ø0.75 TYP
2.312 TYP
Ø0.938 TYP
15.0
2.312 TYP
9.6
15.0
13.0
Ø0.938
TYP
18.1
23.5
25.5
14.1
19.5
21.5
23” Seismic bolted rack mouting details (top view)
19” Seismic bolted rack mouting details (top view)
18.81
16.0
22.81
20.0
0.75
0.75
15.75 15.0
15.75
4.0
15.0
4.0 12.5
1.0
12.5
4.75
6.0
1.0
4.75
6.0
2.16
2.16
24.31
23” Non-Seismic bolted rack mouting details (top view)
20.31
28.1
24.3
21.0
19” Non-Seismic bolted rack mouting details (top view)
2.5
16.0 12.3 9.0
4.1
2X 6.0
5.25
1.9
3.5
4X 5.25
4.03
23” Seismic welded rack mouting details (top view)
NOTE: If rack-mounted equipment extends beyond the base dimensions, install a base extension part #5901537-001
to the front of the base.
1. Refer to the above figure to mark the anchor hole positions.
2. If applicable, place the floor insulation pad where the rack is to be installed.
3. Move the rack to its exact final position over the anchoring holes (and the insulation pad if applicable).
4. Install the anchoring hardware (and the insulation bushing if applicable) for each anchor FINGER TIGHT.
5. Check that the rack is level front-to-back and side-to-side.
6. Add shims as needed under one or two of the corners of the rack, placing the shims as close as possible to
the bolts. To place a shim, take just enough weight off the rack to slide the shim into place.
7. Allow the full weight of the rack to rest on the shims, and then check for level again.
8. Once the rack is level, tighten all bolts to the torque recommended by the anchor manufacturer.
3
Seismic Rack General Installation Guide
Rack Features
Spacing
Use 12-24 thread forming screws.
1.25"
1.75"
Frame Ground
The power plant frame must be connected to the MGB or FGB. This connection is necessary for personnel safety
and to meet many telco-grounding requirements.
Use #6 AWG (16mm) cable for small to medium size power plants and #2/0 cable for large plants (> 800A).
Remove paint in lug contact area (Figure 5) to ensure a good electrical connection.
Frame ground—
¼" on 5/8" centers
5/8" diameter holes
for connection to
overhead trays
Figure 2 — Rack upper cross bar
Connections to Overhead Trays
The rack upper cross bar (Figure 5) has three 5/8" diameter holes to accommodate threaded rod attachment to
overhead trays.
4
Rack Joining Bracket
For systems with multiple racks, bolt each pair of
racks together with brackets #5900708-001. Use one
bracket at the top and one at the bottom.
REV
DESCRIPTION
LTR
NOTE: For Seismic bolted racks only
3
2
4
4
1
1
UNLESS OTHERWISE SPECIFIED
DIM ARE IN INCHES
0.05
X.X
0.01
X.XX
0.005
X.XXX
ANGULAR:
1
INTERPRET DIM AND TOL PER
ASME Y14.5M-1994
THIRD ANGLE PROJECTION
THESE DESIGNS AND SPECIFICATIONS ARE
CONFIDENTIAL, REMAIN THE PROPERTY OF
ALPHA TECHNOLOGIES LTD., AND SHALL NOT BE
COPIED OR USED WITHOUT ITS WRITTEN CONSENT
APPROVALS
DATE
DRAWN
RP
2011/09
CHECKED
SF
2012/02
TITLE:
B
Battery Tray and Breaker Housing
1. Install the battery trays in the rack with the screws and brackets provided with the battery trays.
2. Adjust the guard (Figure 6) to fit the depth of the batteries.
3. Install the breaker housing (Figure 6), if applicable, on the left or right side of the battery tray.
The breaker housing can also be installed in the rack.
NOTE: For Seismic (bolted & welded) racks only
Guard
Breaker housing
Figure 3 — Battery tray accessory (right mount shown)
Alpha Technologies Ltd. For more information visit www.alpha.ca
Canada: Burnaby, British Columbia Tel: 604 436 5900 Fax: 604 436 1233
United States: Bellingham, Washington Tel: 360 647 2360 Fax: 360 671 4936
Alpha Technologies reserves the right to make changes to the products and information contained in this document without notice.
Copyright © 2016 Alpha Technologies. All Rights Reserved. Alpha® is a registered trademark of Alpha Technologies.
member of The Alpha Group™ is a trademark of Alpha Technologies.
member of The
KIT,CO
SE
SIZE TYPE DWG NO.
© ALPHA TECHNOLOGIES LTD
Group™
Doc#: 9400008-J1 RevD
5
D2
SCALE:
NT
Canada: Burnaby, British Columbia Tel: 604 436 5900 Fax: 604 436 1233
United States: Bellingham, Washington Tel: 360 647 2360 Fax: 360 671 4936
Alpha Technologies Ltd. Alpha Technologies reserves the right to make changes to the products and information contained in this document without notice.
Copyright © 2016 Alpha Technologies. All Rights Reserved. Alpha® is a registered trademark of Alpha Technologies.
member of The Alpha Group™ is a trademark of Alpha Technologies.
For more information visit www.alpha.ca
member of The
Doc#: 9400008-J1 RevD
Group™
A
B
C
D
E
5
8
2
5
6
9
1
7
1
4
6
3
3
INSTALL THE CABLE TIE BRACKETS 10 TO THE
UPRIGHT COMPONENTS 1 AND 2 AS NEEDED
WITH THE 12-24 HARDWARE 11 PROVIDED
STEP3:
DO NOT SCALE DRAWING
500LB AND 1000LB RACK ASSEMBLY
INTSTALL THE RACK TOP COMPONENT 7 TO THE UPRIGHT COMPONENTS 1 AND 2
USING THE 3/8"-16 HARDWARE 8 AND 9 PROVIDED.
STEP2:
2
9
INSTALL THE RACK BASE COMPONENTS 6 TO THE UPRIGHT COMPONENTS 1 AND 2
USING THE 3/8"-16 HARDWARE 8 AND 9 PROVIDED.
STEP1:
8
4
2
THIRD ANGLE PROJECTION
INTERPRET DIM AND TOL PER
ASME Y14.5-1994
UNLESS OTHERWISE SPECIFIED
DIM ARE IN INCHES
0.040
X.X
0.020
X.XX
X.XXX
0.010
ANGULAR:
1
11
10
2
DESCRIPTION
CHECKED
DATE
2013/11
2013/11
© ALPHA TECHNOLOGIES LTD
RP
RW
DRAWN
APPROVALS
THESE DESIGNS AND SPECIFICATIONS ARE
CONFIDENTIAL, REMAIN THE PROPERTY OF
ALPHA TECHNOLOGIES LTD., AND SHALL NOT BE
COPIED OR USED WITHOUT ITS WRITTEN CONSENT
LTR
B
SCALE:
BP
DWN
DATE
CHK
1
0370117-F0
A
1 OF 2
1:6 SHEET
REV
SEISMIC RACK ASSEMBLY
REFER TO BUBBLE NUMBER
IN BILL OF MATERIALS.
1
SIZE DWG NO.
TITLE:
QTY
ITEM
REVISIONS
A
B
C
D
E
Canada: Burnaby, British Columbia Tel: 604 436 5900 Fax: 604 436 1233
United States: Bellingham, Washington Tel: 360 647 2360 Fax: 360 671 4936
Alpha Technologies Ltd. Alpha Technologies reserves the right to make changes to the products and information contained in this document without notice.
Copyright © 2016 Alpha Technologies. All Rights Reserved. Alpha® is a registered trademark of Alpha Technologies.
member of The Alpha Group™ is a trademark of Alpha Technologies.
For more information visit www.alpha.ca
member of The
Doc#: 9400008-J1 RevD
Group™
A
B
C
D
E
2
8
9
4
6
1
5
4
INTSTALL THE RACK TOP COMPONENT 7 TO THE UPRIGHT COMPONENTS 1 AND 2
USING THE 3/8"-16 HARDWARE 8 AND 9 PROVIDED.
STEP2:
2
9
1
7
INSTALL THE RACK BASE COMPONENTS 6 TO THE UPRIGHT COMPONENTS 1 AND 2
USING THE 3/8"-16 HARDWARE 8 AND 9 PROVIDED.
STEP1:
8
5
6
INSTALL THE CABLE TIE BRACKETS 10 TO THE
UPRIGHT COMPONENTS 1 AND 2 AS NEEDED
WITH THE 12-24 HARDWARE 11 PROVIDED
3
2
STEP3:
12
1
INSTALL THE OUTER STIFFENERS 4 AND SPACERS 3
TO THE UPRIGHT COMPONENTS 1 AND 2 WITH THE
3/8"-16 HARDWARE 9 AND 12 PROVIDED
3
4
1
2
STEP3:
1500LB RACK ASSEMBLY
9
2
3
DO NOT SCALE DRAWING
B
SCALE:
11
10
2
1
0370117-F0
A
2 OF 2
1:1 SHEET
REV
SEISMIC RACK ASSEMBLY
SIZE DWG NO.
TITLE:
1
A
B
C
D
E
Download PDF