Full 16-bit ISA Bus VDX-6324RD-FD /VDX-6324RD-FD-PLUS

Full 16-bit ISA Bus VDX-6324RD-FD /VDX-6324RD-FD-PLUS
Full 16-bit ISA Bus
VDX-6324RD-FD /VDX-6324RD-FD-PLUS
DM&P Vortex86DX 800MHz
Half-Size CPU Module
with 4S/4USB/VGA/LCD/LAN/GPIO/FDD
256MB DDR2 Onboard
User’s Manual
(Revision 1.1A)
Copyright
The information in this manual is subject to change without notice for continuous improvement in
the product. All rights are reserved. The manufacturer assumes no responsibility for any
inaccuracies that may be contained in this document and makes no commitment to update or to
keep current the information contained in this manual.
No part of this manual may be reproduced, copied, translated or transmitted, in whole or in part,
in any form or by any means without the prior written permission of the ICOP Technology Inc.
Copyright 2009 ICOP Technology Inc.
Manual No. IUM6324-FD000-01 Ver.1.0A
Manual No. IUM6324-FD000-01 Ver.1.1A
August, 2009
September, 2013
Trademarks Acknowledgment
Vortex86DX is the registered trademark of ICOP Technology Inc.
Other brand names or product names appearing in this document are the properties
and registered trademarks of their respective owners. All names mentioned herewith
are served for identification purpose only.
Table
of
Contents
T a b l e o f C o n t e n t s ............................................................. iii
C h a p t e r 1 Introduction……………………………………………1
1.1
Packing List ............................................................ 1
1.2
Product Description ................................................ 1
1.3
Specifications ......................................................... 3
1.4
Board Dimension .................................................... 5
Chapter 2
2.1
2.2
2.3
2.4
2.5
2.6
2.7
2.8
2.9
3.0
Installation……………………………………………..6
Board Outline ......................................................... 6
Connectors & Jumpers Location .................... ........7
Connectors & Jumpers Summary........................... 9
Pin Assignments & Jumper Settings......................11
System Mapping................................................... 24
Watchdog Timer ................................................... 27
GPIO .................................................................... 28
SPI flash ............................................................... 29
PWM .................................................................... 30
IDE to SD ............................................................. 31
Chapter 3
Driver Installation……………………………………32
Appendix ………………………………………………………………..33
A. TFT Flat Panel Data Output ...................................... 33
B. TFT Flat Panel Support List....................................... 34
C. LVDS Flat Panel Support List .................................... 35
D. Flat Panel Hardware Setting ..................................... 36
E. Flat Panel Wiring and Lighting .................................. 37
F. TCP/IP library for DOS real mode .............................. 38
G. BIOS Default Setting ................................................. 39
Warranty............................................................................................ 40
This page is blank
Chapter
1
Introduction
1.1
Packing List
Product Name
Package
Embedded Vortex86DX CPU All-in-One Board
VDX-6324RD-FD
&
VDX-6324RD-FD-PLUS
RS232 cable x 3
PRINTER cable x1
IDE cable x 1
FDD cable x 1
USB cable x 2 (USB port x 2 )
GPIO cable x 1
YKB for PS/2 Keyboard & Mouse x 1
Vortex86DX-6324RD-FD
Vortex86DX
Half-Size CPU Module
1
1.2
Product Description
The VDX-6324-FD family of low-power x86 embedded controller is designed to meet Half-Size
specification with full 16-bit ISA Bus, and integrated with the following features.
800MHz Vortex86DX System-On-Chip
Onboard 4MB SPI Flash
VGA, TFT/LVDS LCD support up to
PC/104-Plus expansion bus
1280x1024 resolution
Meet PC/104 stacking spec.
256 / 512MB DDR2 system memory
2 watchdog timer
Enhanced IDE (UltraDMA-100/66/33)
16~24 PWM channels
10/100Mbps Ethernet
JTAG interface
4 USB 2.0 (host)
AMI BIOS
Up to 4 serial ports
Single voltage +5V DC
Parallel port
Support extended operating
16-bit GPIOs
temperature range of -20°C to +70°C
The VDX-6324-FD Half-Size family of embedded controller is designed with backward
compatibility in mind, to provide migration path for projects facing end-of-life challenges with their
existing x86 based Half-Size controller. The VDX-6324-FD family of controller is designed as a
plug in replacement, with backward compatibility to support legacy software to help extend
existing product life cycle without heavy re-engineering.
VDX-6324RD-FD is suitable for broad range of data-acquisition, Industrial automation, Process
control, Automotive controller, AVL, Intelligent Vehicle management devic,Medical device,
Human machine interface, Robotics, machinery control And more…application that required
small footprint, low-power and low-cost hardware with open industry standard such as Half-Size.
Vortex86DX-6324RD-FD
Vortex86DX Half-Size CPU Module
2
1.3 Specifications
Features
CPU
Cache
BIOS
Bus Interface
System Memory
Watchdog Timer
VGA
LAN
Audio
I /O Interface
Vortex86DX-6324RD-FD
VDX-6324-FD
DM&P SoC CPU Vortex86DX- 800MHz
Real Time Clock with Lithium Battery Backup
L1:16K I-Cache, 16K D-Cache L2:128KB Cache
AMI BIOS
PC/104 Standard Compliant (Optional: PCI-104)
256 /512MB DDR2 Onboard
Software programmable from 30.5 us to 512 seconds x2
sets(W atchdog 1 fully compatible with M6117D)
XGI Volari Z9s Chipset
VGA and TFT Flat Panel Interface Support
LVDS Flat Panel Interface Support (Optional)
Onboard 32MB VGA Memory
Support resolution up to 1280 x 1024
Integrated 10/100M Ethernet
CM119 USB Audio Controller (Optional)
Enhanced IDE port (UltraDMA-100/66/33) x1
FDD x1
RS-232 port x3
RS-232/485/422 port x1 (RS485 Auto Direction)
Parallel port x1
USB port (2.0) x4
16-bit GPIO port x1
10/100Mbps Ethernet port x1
Vortex86DX
Half-Size CPU Module
3
Connectors
Flash Disk Support
PWM
SRAM support
Power Requirement
Dimension
Weight
Operating
Temperature
Vortex86DX-6324RD-FD
2.54 mm ∅ 26-pin box header for Print x1
2.54 mm ∅ 10-pin box header for RS-232 x3
2.54 mm ∅ 10-pin box header for USB x2
2.54 mm ∅ 20-pin box header for 16-bit GPIO x1
2.54 mm ∅ 3-pin header for RS-485 x1
2.54 mm ∅ 2-pin header for Reset x1
2.54 mm ∅ 4-pin header for DC-in x1
2.54 mm ∅ 7-pin header for Redundancy Signal x1(O)
2.54 mm ∅2-pin header for SYS-SW-IN x1 (Opt)
2.0 mm ∅ 44-pin box header for IDE x1
2.0 mm ∅ 34-pin box header for FDD x1
2.0 mm ∅ 44-pin box header for LCD x1
1.25 mm ∅ 6-pin Wafer for JTAG x1
1.25 mm ∅ 4-pin Wafer for Line-out/MIC-in x2 (O)
External RJ-45 connector for Ethernet x1
External Mini DIN connector for KBD/Mouse x1
External D-Sub 15 pin female connector for VGA x1
External D-Sub 9 pin male connector for RS232 x1
Type I/II Compact Flash Slot x1
4-pin Male Power Connector x1
On board 4MB SPI Flash Disk (Driver: A)
44-pin IDE Flash Disk( EmbedDisk 16MB or above)
Compact Flash Type I/II
44-pin IDE to Micro SD (Optional)
16~24 Channels
512KB (Optional)
Single Voltage +5V @720mA
184mm X 122mm (7.24 x4.80 inches)
180g
-20 o C ~ +70 o C
-40°C ~ +85°C (Optional)
Vortex86DX
Half-Size CPU Module
4
1.4 Board Dimension
Vortex86DX-6324RD-FD
Vortex86DX
Half-Size CPU Module
5
Chapter2
Installation
2.1 Board Outline
RS-485
COM4
COM2
RS-232/422/485
COM3
GPIO
LCD
Connector
Display Type
Selection
Power
Connector
Reset
Parallel Port
USB x 2
COM1
JTAG
USB x 2
LAN
FDD
EIDE
Interface
VGA
PS/2
KB/Mouse
Power Connector
PC/104
Flexible DC
Power Connector
(Note1: PCI-104 connector is optional)
(Note2: Audio is optional)
(Note3: Redundancy Signal and System-Fail-SW are optional)
(Note4: COM2 RS232/422/485 is selected by BIOS setting)
Vortex86DX-6324RD-FD
Vortex86DX
Half-Size CPU Module
6
2.2 Connectors & Jumpers Location
Connectors
Vortex86DX-6324RD-FD
Vortex86DX
Half-Size CPU Module
7
Jumpers & LEDs
Vortex86DX-6324RD-FD
Vortex86DX
Half-Size CPU Module
8
2.3
Connectors & Jumpers Summary
Summary Table
Nbr
J1
J2
J3
J4
J5
J6
J7
J8
J9
J10
J11
J12
J17
J18
J19
J20
J21
J22
J24
J26
J27
J28
J29
J30
Description
IDE
USB1
USB2
JTAG
Reset
Redundancy (Optional)
System –Fail-Switch (Optional)
PS/2 Keyboard & Mouse
COM1(TTL/GPIO-P4 / PWMx8)
COM2(RS232/RS485/RS422)
GPIO ( Port 0 / 1 /PWMx16)
RS-485
Power Connector
Power Connector
COM3
PRINT
COM4
PC/104 Connector – 64 pin
PC/104 Connector – 40 pin
4P Power Source (Interconnect
to PC/104 – J22)
PC/104 + (Optional)
VGA
LCD
Display type Setup
J35
J36
J37
J38
J39
10/100Base-T Ethernet LAN
LINE-OUT (Optional)
MIC-IN (Optional)
JTAG Disable (Default setting)
Vortex86DX-6324RD-FD
Type of Connections
Box Header, 2.0∅ , 22x2
Box Header, 2.54∅ , 5x2
Box Header, 2.54∅ , 5x2
Wafer, 1.25∅ , 6x1
Pin Header, 2,54∅,1x2
Pin Header, 2.54∅, 7x1
Pin Header, 2.54∅ , 2x1
Mini-Din Connector
D-Sub Connector
Box Header, 2.54∅ 5x2
Box Header, 2.54∅ ,10x2
Molex Header,2.54∅ , 3x1
Box Header, 5.0∅ Molex
Terminal Block 5.0∅,2x1
Pin Header, 2.54∅, 5x2
Pin Header, 2.54∅ ,13x2
Pin Header, 2.54∅, 5x2
Box Header, 2.54∅ 32x2
Box Header, 2.54∅ ,20x2
Pin Header, 2.54∅ , 4x1
Box Header, 2.0∅ , 30x4
D-Sub female connector
Box Header,2.0∅ ,22x2
Pin Header, 2.54∅ , 3x1
RJ45 Connector
Wafer, 1.25∅ , 4x1
Wafer, 1.25∅ , 4x1
Pin Header, 2,54∅,1x2
Vortex86DX
Half-Size CPU Module
Pin nbrs.
44-pin
10-pin
10-pin
6-pin
2-pin
7-pin
2-pin
6-pin
9-pin
10-pin
20-pin
3-pin
4-pin
2-pin
10-pin
26-pin
10-pin
64-pin
40-pin
4-pin
120-pin
15-pin
44-pin
3-pin
8-pin
4-pin
4-pin
2-pin
9
J40
J41
J42
PWR-L
ED
IDELED
MTBF-
Master/Slave for IDE & CF
Console Redirection (Optional)
FDD
Power Active LED (Red)
Slide Switch
Pin Header, 2,54∅,1x2
Pin Header, 2.0∅ ,17x2
LED-SMD
IDE Active LED (Green )
LED-SMD
MTBF-Out (Orange)
LED-SMD
LED
CF1 Compact Flash
SP1 BUZZER
Vortex86DX-6324RD-FD
Type I/II CF Connector
Vortex86DX
Half-Size CPU Module
3-pin
2-pin
34-pin
50-pin
10
2.4 Pin Assignments & Jumper Settings
J1: IDE (44 Pins)
Pin #
1
3
5
7
9
11
13
15
17
19
21
23
25
27
29
31
33
35
37
39
41
43
Signal Name
IDERST
IDED7
IDED6
IDED5
IDED4
IDED3
IDED2
IDED1
IDED0
GND
IDEREQ
IDEIOW
IDEIOR
ICHRDY
IDEACK
IDEINT
IDESA1
IDESA0
IDECS-0
IDELED
VCC
GND
Pin # Signal Name
2
GND
4
IDED8
6
IDED9
8
IDED10
10
IDED11
12
IDED12
14
IDED13
16
IDED14
18
IDED15
20
NC
22
GND
24
GND
26
GND
28
GND
30
GND
32
NC
34
IDECBLID
36
IDESA2
38
IDECS1
40
GND
42
VCC
44
NC
J2: USB 1
Pin #
1
3
5
7
9
Signal Name Pin # Signal Name
VCC
2
VCC
LUSBD04
LUSBD1LUSBD0+
6
LUSBD1+
GND
8
GND
GGND
10
GGND
Vortex86DX-6324RD-FD
Vortex86DX
Half-Size CPU Module
11
J3: USB 2
Pin #
1
3
5
7
9
Signal Name Pin # Signal Name
VCC
2
VCC
LUSBD24
LUSBD3LUSBD2+
6
LUSBD3+
GND
8
GND
GGND
10
GGND
J4: JTAG (Default setting: off)
Pin #
1
3
5
Signal Name Pin # Signal Name
VCC
2
GND
TCK
4
TDO
TDI
6
TMS
J5: RESET
Pin #
1
Signal Name Pin # Signal Name
Reset
2
GND
J6: Redundancy (Optional)
Pin #
Signal Name
1
3
5
7
GND
SYS-FAIL-IN
SYS-GPCS-IN
RXD9\
Pin # Signal Name
2
4
6
SYS-FAIL-OUT
GPCS0
TXD9\
J7: System-Fail-Switch (Optional)
Pin #
1
2
Signal Name
SYS-SW-IN
GND
Vortex86DX-6324RD-FD
Vortex86DX
Half-Size CPU Module
12
J8: PS/2 KBD / Mouse
Pin #
1
3
5
7
9
Signal Name Pin # Signal Name
KBCLK
2
MSCLK
GND
4
KBDAT
MSDAT
6
VCC
GGND
8
GGND
GGND
J9: COM 1 (Optional: TTL/ GPIO-P4 / PWMx8)
Pin #
1
3
5
7
9
11
Signal
Name
DCD1
TXD1
GND
RTS1
RI1
GND
Pin #
2
4
6
8
10
Signal
Name
RXD1
DTR1
DSR1
CTS1
GND
J10: COM2 RS232 / RS422 / RS485 (Change setting by BIOS)
Pin #
Signal Name
Pin #
Signal Name
1
DCD2/ 422TX- / RS485-
2
RXD2 / 422TX+ / RS485+
3
TXD2 / 422RX+
4
DTR2 / 422RX-
5
GND
6
DSR2
7
RTS2
8
CTS2
9
RI2
10
NC
Vortex86DX-6324RD-FD
Vortex86DX
Half-Size CPU Module
13
J11: GPIO (Port 0 / Port 1/PWMx16)
Pin #
1
3
5
7
9
11
13
15
17
19
Signal Name
GND
GP00
GP01
GP02
GP03
GP04
GP05
GP06
GP07
VCC
Pin # Signal Name
2
VCC
4
GP10
6
GP11
8
GP12
10
GP13
12
GP14
14
GP15
16
GP16
18
GP17
20
GND
J12: RS485 (Auto direction)
Pin #
Signal Name
1
RS485+
2
RS485-
3
GND
J17: Power Connector – 4-pin Header (P4 Molex 5mm)
Pin #
Signal
Name
1
+5V
2
GND
3
GND
4
+12V
Vortex86DX-6324RD-FD
Vortex86DX
Half-Size CPU Module
14
J18: Power Connector (Terminal Block 5.0mm)
Pin #
Signal Name
1
2
+5V
GND
J19: COM3
Pin #
1
3
5
7
9
Signal Name Pin # Signal Name
DCD3
2
RXD3
TXD3
4
DTR3
GND
6
DSR3
RTS3
8
CTS3
RI3
10
NC
J20: PRINT
Pin #
1
2
3
4
5
6
7
8
9
10
11
12
13
Signal Name
STBPD0
PD1
PD2
PD3
PD4
PD5
PD6
PD7
ACKBUSY
PE
SLCT
Pin # Signal Name
14
AFD15
ERR16
INIT17
SLIN18
GND
19
GND
20
GND
21
GND
22
GND
23
GND
24
GND
25
GND
26
NC
J21: COM4
Pin #
1
3
5
7
9
Signal Name Pin # Signal Name
DCD4
2
RXD4
TXD4
4
DTR4
GND
6
DSR4
RTS4
8
CTS4
RI4
10
NC
Vortex86DX-6324RD-FD
Vortex86DX
Half-Size CPU Module
15
J22: PC/104 Connector – 64pin
Pin #
1
3
5
7
9
11
13
15
17
19
21
23
25
27
29
31
33
35
37
39
41
43
45
47
49
51
53
55
57
59
61
63
Signal Name
IOCHCHK
*
SD7
SD6
SD5
SD4
SD3
SD2
SD1
SD0
IOCHRDY
AEN
SA19
SA18
SA17
SA16
SA15
SA14
SA13
SA12
SA11
SA10
SA9
SA8
SA7
SA6
SA5
SA4
SA3
SA2
SA1
SA0
GND
Pin # Signal Name
2
GND
4
6
8
10
12
14
16
18
20
22
24
26
28
30
32
34
36
38
40
42
44
46
48
50
52
54
56
58
60
62
64
Vortex86DX-6324RD-FD
RESETDRV
VCC
IRQ9
-5V
DRQ2
-12V
OWS
+12V
GND
SMEMW *
SMEMR *
IOW *
IOR *
DACK3 *
DRQ3
DACK1 *
DRQ1
REFRESH *
SYSCLK
IRQ7
IRQ6
IRQ5
IRQ4
IRQ3
DACK2 *
TC
BALE
VCC
OSC
GND
GND
Vortex86DX
Half-Size CPU Module
16
J24: PC/104 Connector – 40pin
Pin #
1
3
5
7
9
11
13
15
17
19
21
23
25
27
29
31
33
35
37
39
Signal Name Pin # Signal Name
GND
2
GND
MEMCS16 * 4
SBHE *
IOCS16 *
6
SA23
IRQ10
8
SA22
IRQ11
10
SA21
IRQ12
12
SA20
IRQ15
14
SA19
IRQ14
16
SA18
DACK0 *
18
SA17
DRQ0
20
MEMR *
DACK5 *
22
MEMW *
DRQ5
24
SD8
DACK6 *
26
SD9
DRQ6
28
SD10
DACK7 *
30
SD11
DRQ7
32
SD12
VCC
34
SD13
MASTER * 36
SD14
GND
38
SD15
GND
40
NC
J26: 4P Power Source (Interconnect to PC/104 – J22)
Pin #
1
2
3
4
Signal Name
-5V
-12V
+12V
GND
Vortex86DX-6324RD-FD
Vortex86DX
Half-Size CPU Module
17
J27: PC/104 + (Optional)
VI/O Default setting: +5V
If you need to use VI/O as +3.3V, please see the page 19.
Pin #
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
A
B
C
D
GND
NC
+5V
AD00
VI/O(+5V)
AD02
AD01
+5V
AD05
GND
AD04
AD03
C/BE0#
AD07
GND
AD06
GND
AD09
AD08
GND
AD11
VI/O(+5V) AD10
GND
AD14
AD13
GND
AD12
+3.3V
C/BE1#
AD15
+3.3V
SERR#
GND
NC
PAR
GND
PERR#
+3.3V
NC
STOP#
+3.3V
LOCK#
GND
+3.3V
TRDY#
GND
DEVSEL#
FRAME#
GND
IRDY#
+3.3V
GND
AD16
+3.3V
C/BE2#
AD18
+3.3V
AD17
GND
AD21
AD20
GND
AD19
+3.3V
AD23
AD22
+3.3V
IDSEL0
GND
IDSEL1
IDSEL2
AD24
C/BE3# VI/O(+5V) IDSEL3
GND
AD26
AD25
GND
AD29
+5V
AD28
AD27
+5V
AD30
GND
AD31
REQ0#
GND
REQ1#
VI/O(+5V)
GND
REQ2#
+5V
GNT0#
GNT1# VI/O(+5V) GNT2#
GND
+5V
CLK0
GND
CLK1
CLK2
+5V
CLK3
GND
GND
INTD#
+5V
RST#
+12V
INTA#
INTB#
INTC#
-12V
NC
NC
GND
Vortex86DX-6324RD-FD
Vortex86DX
Half-Size CPU Module
18
Please remove the R229 and add 0 ohm (1206 type) on R230
Vortex86DX-6324RD-FD
Vortex86DX
Half-Size CPU Module
19
J28: VGA (D-Sub connector)
Pin #
1
3
5
7
9
11
13
15
Signal Name
R OUT
B OUT
GND
GND
VCC
NC
HSYNC
DDCCLK
Pin # Signal Name
2
G OUT
4
NC
6
GND
8
GND
10
GND
12
DDCDAT
14
VSYNC
J29: LCD Connector
Pin #
1
3
5
7
9
11
13
15
17
19
21
23
25
27
29
31
33
35
37
39
41
43
Signal Name
+3.3V
LG2
LG4
NC
LR0
LR2
LR4
GND
NC
NC
NC
LB0
LB2
LB4
NC
LG0
GND
NC
NC
NC
NC
LBACKL
Pin # Signal Name
2
+3.3V
4
LG3
6
LG5
8
NC
10
LR1
12
LR3
14
LR5
16
NC
18
NC
20
GND
22
NC
24
LB1
26
LB3
28
LB5
30
NC
32
LG1
34
GND
36
LCLK
38
LDE
40
LHSYNC
42
LVSYNC
LVDDEN
44
(Please refer to Appendix A, for TFT Flat Panel Data Output)
Vortex86DX-6324RD-FD
Vortex86DX
Half-Size CPU Module
20
J30~J35: Display type setup (CRT /LCD)
Connector
J30
J31
J32
J33
J34
J35
Pin #
Signal Name
1
VCC
2
GPIOA
3
GND
1
VCC
2
GPIOB
3
GND
1
VCC
2
GPIOC
3
GND
1
VCC
2
GPIOD
3
GND
1
VCC
2
GPIOE
3
GND
1
VCC
2
GPIOF
3
GND
(Please refer to Appendix D, for Display type setup)
J36: LAN
Pin #
1
3
5
7
Signal Name Pin # Signal Name
TD+
2
TDRO+
4
NC
NC
6
RONC
8
NC
Vortex86DX-6324RD-FD
Vortex86DX
Half-Size CPU Module
21
J37: LINE OUT (Optional)
Pin #
1
2
3
4
Signal Name
LOUTR
GND
GND
LOUTL
J38: MIC-IN (Optional)
Pin #
1
2
3
4
Signal Name
MICVREF
GND
GND
MIC-IN
J39: JTAG Disable (Default setting: Pin 1 & Pin 2 short)
Pin #
1
Signal Name Pin # Signal Name
GND
2 JTAG Disable
J41: Console Redirection (Pin 1 & Pin 2 short) Optional
Pin #
1
Signal Name Pin # Signal Name
Console_Red 2
GND
Vortex86DX-6324RD-FD
Vortex86DX
Half-Size CPU Module
22
J42: FDD
Pin # Signal Name
Pin #
Signal Name
1
GND
2
DENSEL
3
GND
4
NC
5
GND
6
NC
7
GND
8
INDEX\
9
GND
10
MTRO\
11
GND
12
DS1\
13
GND
14
DS0\
15
GND
16
MTR1\
17
GND
18
DIR\
19
GND
20
STEP\
21
GND
22
WD\
23
GND
24
WG\
25
GND
26
TR0\
27
GND
28
WP\
29
GND
30
RD\
31
GND
32
HDSEL\
33
GND
34
DSKCHG\
Vortex86DX-6324RD-FD
Vortex86DX
Half-Size CPU Module
23
2.5
System Mapping
Vortex86DX-6324RD-FD
Vortex86DX
Half-Size CPU Module
24
Vortex86DX-6324RD-FD
Vortex86DX
Half-Size CPU Module
25
Vortex86DX-6324RD-FD
Vortex86DX
Half-Size CPU Module
26
2.6
Watchdog Timer
There are two watchdog timers in Vortex86SX/DX CPU. One is compatible with M6117D
watchdog timer and the other is new. The M6117D compatible watchdog timer is called WDT0
and the new one is called WDT1.
We also provide DOS, Linux and WinCE example for your reference. For more technical support,
please visit: http://www.dmp.com.tw/tech or download the PDF file:
http://www.dmp.com.tw/tech/vortex86dx/
Vortex86DX-6324RD-FD
Vortex86DX
Half-Size CPU Module
27
2.7
GPIO (General Purpose Input / Output)
40 GPIO pins are provided by the Vortex86SX/DX for general usage in the system. All GPIO pins
are independent and can be configured as inputs or outputs, with or without pull-up/pull-down
resistors.
We also offer DOS, Linux and WinCE example for your reference. For more technical support,
please visit: http://www.dmp.com.tw/tech or download the PDF file:
http://www.dmp.com.tw/tech/vortex86dx/
Vortex86DX-6324RD-FD
Vortex86DX
Half-Size CPU Module
28
2.8
SPI flash (Serial Peripheral Interface)
As SPI Flash (Serial Peripheral Interface) offers many benefits including: reduced controller pin
count, smaller and simpler PCBs, reduced switching noise, less power consumption, and lower
system cost
Many of users may consider using a formatted SPI flash to boot for the system or emulate SPI
flash as Floppy (A: Driver or B: Driver). Then you must know how to set for this condition in
CMOS Setup and boot up under DOS 6.22, X-DOS, DR-DOS and Free DOS.
For more technical support, please visit: http://www.dmp.com.tw/tech or download the PDF file:
http://www.dmp.com.tw/tech/vortex86dx/
Vortex86DX-6324RD-FD
Vortex86DX
Half-Size CPU Module
29
2.9
PWM (Pulse-width modulation)
Pulse-width modulation (PWM) of a signal or power source involves the modulation of its duty
cycle, to either convey information over a communications channel or control the amount of
power sent to a load.
The popular applications of pulse width modulation are in speed control of electric motors,
volume control of Class D audio amplifiers or brightness control of light sources and many other
power electronics applications.
The Vortex86DX SoC integrated 32 channels of PWM interface enabling the Automation, robotic
industry to a New Age x86 SoC platform and we also offer the sample code of PWM which will
guide the engineer to control the PWM functionality smoothly.
For more inquire of this sample code that please contact our sales team or mail to:
info@icop.com.tw
Vortex86DX-6324RD-FD
Vortex86DX
Half-Size CPU Module
30
3.0
IDE to SD (Micro-SD)
Vortex86DX SoC also built-in simulation circuit to adapt SD to IDE in order to allow your system
to recognize Micro-SD card as C: or D: Driver
SD-1917: 44 pins IDE to SD Adapter is an ideal solution for industrial PC or embedded system
and 44 pins IDE to SD Adapter can be easily installed on all VDX-63xx CPU boards. You or your
customers just do the BIOS setting and use SD-1917 to connect IDE connector of VDX-63xx
directly.
For further inquiries of SD-1917, please contact ICOP sales team or mail to: info@icop.com.tw
for your request.
<BIOS setting>
Get into the BIOS setup Utility
Choose Primary IDE Pin Select: SD card
Press “F10” to Save configuration changes and exit setup
SD-1917
SD-1917: http://www.icop.com.tw/pddetail.aspx?id=125&pid=4
Vortex86DX-6324RD-FD
Vortex86DX
Half-Size CPU Module
31
Chapter
3
Driver Installation
VGA
The Vortex86DX processor also use external Display chip ““Volari™ Z9s” which is an ultra low
powered graphics chipset with total power consumption at around 1-1.5 W. It is capable in
providing VGA display output upto 1600x1200. With DVO interface, developers could easily
connect flat Panel to support TFT and LVDS output.
LAN
The Vortex86DX processor also integrated 10/100Mbps Ethernet controller that supports both
10/100BASE-T and allows direct connection to your 10/100Mbps Ethernet based Local Area
Network for full interaction with local servers, wide area networks such as the Internet.
I/O and IRQ settings can be done by software with the supplied utility software, or it can be set
for Plug and Play compatibility. The controller supports: Half / Full-Duplex Ethernet function to
double channel bandwidth, auto media detection.
Operating system support
The VDX-6324RD-FD ISA CPU board provides the VGA and LAN drivers for DOS 6.22 Windows
CE 5.0, CE 6.0, Windows 98, Windows XP Professional, Windows Embedded standard (XPE)
and Windows 2000.
Please download the drivers for VDX-6324RD board on ICOP official website:
http://www.icop.com.tw/en/product/Half-Size-SBC-VDX-6324D-FD-80
0MHz/VDX-6324D-FD.html
VDX-6324RD-FD also supports most of the popular Linux distributions, for more detail
information, please visit DMP official website: http://www.dmp.com.tw/tech/vortex86dx/
.
Vortex86DX-6324RD-FD
Vortex86DX
Half-Size CPU Module
32
Appendix
A.
TFT Flat Panel Data Output
Vortex86DX-6324RD-FD
Vortex86DX
Half-Size CPU Module
33
B.TFT Flat Panel Support List
Size
Brand
Resolution
Model No.
5.7”
Data image
320x240
FG050701DSSWBG01
5.7”
Optrex
320x240
55264GD057J-FW-ABN
5.7”
TOSHIBA
320x240
LTA057A343F
5.7”
Sharp
320x240 (QVGA / VGA)
LQ057Q3DC02
5.7”
Kyocera
320x240 (QVGA / VGA)
TCG057QV1AC-G10
5.7”
PVI
320x240 (QVGA / VGA)
PD057VU4 /U5
5.7”
Data image
640x480
FG050710DSSWJG01/DG01
5.7”
Ampire
640x480
AM-640480GTMQW-T00H
5.7”
Sharp
640x480
LQ057V3DG01
5.7”
CPT
640x480
CLAA057VA01
6.4”
LG-PHILIPS
640x480
LB064V02
6.4”
PVI
640x480
PD064VT2 /VT4 /VT5
7”
Data image
800x480
FG0700A0DSSWBG01
7”
LG-PHILIPS
800x480
LB070WV1
7”
HITACHI
800x480
TX18D57VM2BAA
7”
Samsung
800x480 (TFT 24bits)
LMS700KF05
7”
NEC
800x480
NL3224BC35-20
7”
PVI
800x480
PM070WL4
8”
Sharp
640x480
LQ080V3DG01
8”
AUO
800x600 (TFT 24bits)
A080SN01 V0
8.4”
Sharp
800x600
LQ084S3DG01
10.4”
PVI
640x480
PD104VT1/VT2
10.4”
Sharp
Vortex86DX-6324RD-FD
12.1”
NEC
640x480
Vortex86DX
800x600
LQ104V1DG51/DG61
Half-Size CPU Module
NL8060BC31-01
34
C. LVDS Flat Panel Support List
If you would like to use LVDS Flat Panel with Vortex86SX / Vortex86DX series, please contact
our regional sales to get ICOP-0096 information or visit ICOP website:
http://www.icop.com.tw/pddetail.aspx?id=65&pid=4
ICOP–0096: 18-bit TFT to LVDS converter and Cable-LVDS-30: LVDS Cable 30cm
Approved LVDS Flat Panel List
Size
Brand
Resolution
Model No.
3.5”
PVI
640x480
PD035VL1
5”
PVI
640x480
PD050VL1
6.5”
AUO
640x480
G065VN01
8.4”
AUO
800x600
G084SN03
8.9”
AUO
1024x600
A089SW01
8.9”
CPT
1024x600
CLAA089NA0ACW
Vortex86DX-6324RD-FD
Vortex86DX
Half-Size CPU Module
35
D.
10.4”
AUO
800x600
G104SN02
12.1”
AUO
800x600
G121SN01
15”
AUO
1024x768
G150XG01
Flat Panel Hardware Setting:
The VDX-6324RD-FD offers the Hardware setting for the various TFT LCD Flat Panels support
and please make sure the jumper setting (J30~J35) before you connect the LCD.
Display type setup
LCD
Connector
1-2
2-3
J30
C
J31
C
J32
X
X
J33
X
X
J34
C
C
J35
Note: "C" means close; "X" means open
Vortex86DX-6324RD-FD
Vortex86DX
Half-Size CPU Module
36
E.
Flat Panel Wiring and Lighting
Hardware
Before you connect the TFT LCD Flat Panel with VDX-6324RD-FD, please make sure
that the input Voltage of LCD is 3.3V.
BIOS
Please contact or e-mail our regional sales to get the special BIOS for any TFT LCD
Flat Panels.
Wiring LCD Cable
Please refer to Page 20 (J29: LCD connector) and Page 33~37. Or for more LCD lighting
and integration service, please contact our regional sales or mail to info@icop.com.tw ,if
you have any questions.
Vortex86DX-6324RD-FD
Vortex86DX
Half-Size CPU Module
37
F. TCP/IP library for DOS real mode
DSock is a TCP/IP library for DOS real mode, which is used by RSIP. It provides simple C
functions for programmer to write Internet applications. ICOP also provide Internet examples
using DSock: BOOTP/DHCP, FTP server, SMTP client/server, HTTP server, TELNET server,
Talk client/server, etc.
DSock provides a lot of example source code. Programmer can add Internet functions to their
project easily and save development time. With a utility "MakeROM”, programmer also can make
a ROM image to fit their application, those examples can be seen in the following Application
systems: Mity-Mite Serial Server, Web Camera Tiny Server and RSIP Serial Server.
DSock is free for All ICOP products using M6117D/Vortex86/Vortex86SX/Vortex86DX CPU and
ICOP also provide the business version of DSock for those customers who are using other x86
CPUs.
If you would like to use DSock or business version of DSock, Please mail to info@icop.com.tw or
contact your regional sales.
Please download the trial DSock software and Utilities from our website:
http://www.dmp.com.tw/tech/dmp-lib/dsock/
Vortex86DX-6324RD-FD
Vortex86DX
Half-Size CPU Module
38
G. BIOS Default setting
If the system cannot be booted after BIOS changes are made, Please follow below procedures in
order to restore the CMOS as default setting.
Press “End” Key, when the power on
Press <Del> to enter the AMI BIOS setup
Press “F9” to Load Optimized Defaults
Press “F10” to Save configuration changes and exit setup
Vortex86DX-6324RD-FD
Vortex86DX
Half-Size CPU Module
39
Warranty
This product is warranted to be in good working order for a period of one year from the date of purchase.
Should this product fail to be in good working order at any time during this period, we will, at our option,
replace or repair it at no additional charge except as set forth in the following terms. This warranty does not
apply to products damaged by misuse, modifications, accident or disaster. Vendor assumes no liability for
any damages, lost profits, lost savings or any other incidental or consequential damage resulting from the
use, misuse of, originality to use this product. Vendor will not be liable for any claim made by any other
related party. Return authorization must be obtained from the vendor before returned merchandise will be
accepted. Authorization can be obtained by calling or faxing the vendor and requesting a Return
Merchandise Authorization (RMA) number. Returned goods should always be accompanied by a clear
problem description.