power distribution unit acar-800 (5 + 2 outlets) +sat+av

power distribution unit acar-800 (5 + 2 outlets) +sat+av
Code: ACAR-800
POWER DISTRIBUTION UNIT ACAR-800 (5 + 2 OUTLETS) +SAT+AV+TEL
Net: 20.84 EUR Gross: 25.63 EUR
The ACAR-800 device is full protection of RTV and computers, and their
equipment. It is equipped with 5 grounded outlets and 2 flat non-grounded
outlets.
The antenna protection part allows to protect against overvoltages TV-set
receivers, VTRs, tuners, etc. connected to the antenna instalation. It can
also protects SAT signal installation and ADSL transmission phone line.
The power protection part uses overvoltage protection system additionally
equipped with protection indication. All power outlets have a child
protection against electric shock. It has the power switch with light
indicator built-in, which informs about the power voltage in outlets, auto
fuse and possibility to place a power cable in four directions. Aesthetic
design and high-quality construction with non-flammable plastic material.
SPECIFICATION
Nominal voltage:
230 V AC / 50 Hz
Total maximal current:
10 A
Nominal discharge current for TEL line:
2 kA (La,b/PE) - (8/20µs)
Maximal total load:
2300 W
Response time:
< 25 ns
Number of outlets:
7 outlets, two-contact 10A/250V, including 5 ones with ground contact
TEL line maximal stroke current:
5 kA (La,b/PE) - (8/20µs)
Leak current:
< 0.5 mA
Nominal voltage of surge suppressor:
250 V / 50 Hz
Protection level of surge suppressor:
≤ 1.3 kV (L/N)
Nominal stroke current:
2 kA (L/N)
ADSL TELEPHONE LINE:
Switch:
double-track, with light indication
Phone sockets type:
RJ11 (6P4C)
Protected wires of ADSL line:
2z4
Maximum stroke current:
6.5 kA (L/N) - (8/20µs)
Rise time of surge suppressor for TEL line:
< 25 ns
Nominal voltage of surge suppressor for TEL line:
150 V
Level of surge protection for TEL line:
≤ 1 kV (La,b/PE)
Electric shock protection system:
Ground connectors (pins) connected with ground wire of AC mains
TV LINE:
TV sockets type:
1 male socket, 1 female socket
TV bandwidth:
47 ... 950 MHz
Rise time of surge suppressor for TV line:
< 25 ns
DELTA-OPTI Monika Matysiak / VAT:PL5251295225 / 60-713 Poznań, ul. Graniczna 10
Tel:+48 61 866 71 48 / GSM:+48 607 60 11 66 / Fax:+48 61 864 69 65 / e-mail:shop@delta.poznan.pl
Monday-Friday: 8.00-19.00 / Saturday: 8.00-14.00
2017-07-26
ACAR-800
1/3
Nominal voltage of surge suppressor for TV line:
95 V
Level of surge protection for TV line:
≤ 0.6 kV
Nominal discharge current for TV line:
2 kA (8/20µs)
(wire/PE, shield/PE)
TV line maximal stroke current:
5 kA (8/20µs)
(wire/PE, shield/PE)
SAT LINE:
SAT sockets type:
2 F type female sockets
SAT bandwidth:
950 ... 2150 MHz
Rise time of surge suppressor for SAT line:
< 25 ns
Nominal voltage of surge suppressor for SAT line:
95 V
Level of surge protection for SAT line:
≤ 0.6 kV
Nominal discharge current for SAT line:
2 kA (8/20µs)
(wire/PE, shield/PE)
SAT line maximal stroke current:
5 kA (8/20µs)
(wire/PE, shield/PE)
Length of the cable:
1.5 m
Dimensions:
445 x 54 x 55 mm
Weight:
0.48 kg
Guarantee:
2 years
PRESENTATION
Top view:
Sockets: phone line, TV antenna, SAT:
DELTA-OPTI Monika Matysiak / VAT:PL5251295225 / 60-713 Poznań, ul. Graniczna 10
Tel:+48 61 866 71 48 / GSM:+48 607 60 11 66 / Fax:+48 61 864 69 65 / e-mail:shop@delta.poznan.pl
Monday-Friday: 8.00-19.00 / Saturday: 8.00-14.00
2017-07-26
ACAR-800
2/3
In the kit:
Package:
PACKAGE PARAMETERS
Dimensions (L x W x H): 480x100x55 mm Package: karton Gross Weight: 0.82 kg
DELTA-OPTI Monika Matysiak / VAT:PL5251295225 / 60-713 Poznań, ul. Graniczna 10
Tel:+48 61 866 71 48 / GSM:+48 607 60 11 66 / Fax:+48 61 864 69 65 / e-mail:shop@delta.poznan.pl
Monday-Friday: 8.00-19.00 / Saturday: 8.00-14.00
2017-07-26
ACAR-800
3/3
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertising