ZEISS Primo Star
Product Information
Version 2.0
ZEISS Primo Star
Robust, User-Friendly, and Affordable:
The Right Microscope for Educators and Students Alike
Show Students the Secrets of Specimens under a Microscope.
Watch Them Learn!
›
In Brief
›
The Advantages
›
The Applications
›
The System
›
Technology and Details
› Service
You place very specific demands on the microscopes you use in your classes.
And rightly so. That's why ZEISS brings you Primo Star, a microscope especially
suited to educational settings. As a classroom microscope Primo Star is designed
for long-term use and extreme durability. And so easy to use that students will
spend their time learning, not fiddling with technology.
Connect your classrooms: Use Primo Star with its integrated 5 megapixel
HD streaming camera in conjunction with Labscope, the iPad imaging app from
ZEISS, to network the microscopes in your classroom. This will make teaching
easier for you and help students learn quickly and more effectively.
Primo Star incorporates 160 years of ZEISS leadership in optical microscopy,
specially adapted to the most sophisticated environmental conditions of today's
classroom settings and laboratory work.
Animation
2
Simpler. More Intelligent. More Integrated.
›
In Brief
›
The Advantages
›
The Applications
›
The System
›
Technology and Details
› Service
Successful Teaching and Enthusiastic Students
The Connected Classroom
Clever Details for Greater Freedom
Primo Star delivers everything that matters in an
Consider the advantages of having the camera
Primo Star's modern look is esthetically pleasing,
educational setting: the ability to view stained tissue
integrated into the tube and a number of interface
but that's just the start: the sleek design houses
sections, unstained cells in phase contrast, cross-
options. You can connect microscopes in your
an array of smart features. You can use either a
sections of plant stems – and to analyze pathogens.
classroom to each other, using Labscope, the iPad
30-watt halogen bulb or energy-saving LED illumi-
imaging app from ZEISS. Then connect them in
nation with its stable color temperature and illu-
The Fixed-Köhler version of Primo Star comes with
turn to HD monitors or projectors to share your
mination intensity. The built-in carrying handle lets
the Plan-ACHROMAT 100x/0.8 dry objective. Or
images or videos with students. Or use the USB
you move the microscope safely, for example,
you can work with the Full Köhler versions. Either
port for free access to the powerful imaging soft-
when storing it away. Use the handy battery supply
way, Primo Star shows the intensity of illumination
ware ZEN lite. Or save your data directly to the
unit in areas with fluctuating electricity or none at
on both sides of the stand so you can keep an eye
integrated SD card. Give your students the full
all. Add on the fluorescence tube and turn your
on all the microscopes in the room – even at a
experience of mutual learning with brilliant images.
Primo Star into a LED fluorescence microscope.
distance.
3
Your Insight into the Technology Behind It
›
In Brief
›
The Advantages
›
The Applications
›
The System
›
Technology and Details
› Service
Phototube
ZEISS Primo Star:
Beam Path of Transmitted Light
In microscopes using Köhler illumination only the
area of the specimen being observed is illuminated,
thus diffused light is minimized. At the same time,
Eyepieces
Stand
the illuminating light cone adjusts to the opening
cone of the objective to make use of the numerical
aperture of the optics. The tools used to achieve
this are the field diaphragm and the condenser,
which contains the aperture diaphragm. Adjusting
the Köhler illumination, the field diaphragm is displayed on the sample using the condenser.
Observation
tube
Power supply
Tube
lens
Objective
This diaphragm determines which part of the sample
is illuminated. The aperture diaphragm is adjusted
so that at least two-thirds of the objective pupil's
diameter is illuminated. Thus, the illuminating
light cone is adjusted to the objective's numeric
aperture. After correctly setting the Köhler illumination, the illumination of the specimen as well as
the contrast and resolution of the image will be
Condenser
Aperture
diaphragm
Condenser
Field
diaphragm
perfectly harmonized.
Optical beam path of ZEISS Primo Star
4
Expand Your Possibilities
›
In Brief
›
The Advantages
›
The Applications
›
The System
›
Technology and Details
› Service
ZEISS Labscope –
Your Doorway to the Digital World
Use Labscope, the iPad imaging app from ZEISS,
to display all the live images from your connected
microscopes. Select any student's image with just
one click. Record images and videos with the high
resolution of 5 megapixels. You can annotate your
images and, for example, measure distances. Then
share your images, reports, and videos with others
via email, social media or cloud services. With
Labscope, you can save your images in the ZEN
compatible .czi file format, which includes all
metadata and a separate annotation layer.
Or select the .jpg format to save space. Downloading Labscope is fast and easy from the Apple
App Store – and it's 100% free.
5
Tailored Precisely to Your Applications
› In Brief
›
The Advantages
›
The Applications
›
The System
›
Technology and Details
› Service
Typical applications, typical samples
Task
ZEISS Primo Star offers
Unstained cells in phase contrast, such as the examination of oral
mucosa; for example, extremely fine structures such as diatoms in
darkfield
Fixed-Köhler versions
Dry objective
Anti-theft protection for objectives
Transport handle
Illumination intensity display
Vocational and advanced training in:
Biology
Brightfield applications, such as determining the structure of a cell,
analyzing plant cross-sections
Human and
veterinary medicine
Agricultural and
environmental sciences
Examining tissue samples and blood slides in the fields of anatomy,
pathology, hematology, and zoology for the purpose of recognizing
typical disease patterns
Studying diseases and pests on cultivated plants; epidemiology,
disease development and the course of infection; diagnosis of
pathogenic organisms and pests
Food science,
microbiological training
Morphology of bacteria cells such as Bacillus subtilis,
Staphylococcus epidermidis, Micrococcus luteus, Escherichia coli
Medical professions,
laboratory applications in schools and universities
Laboratory examinations of bodily fluids, tissues, and excretions,
such as hematological examinations regarding cell morphology
of blood and tissue cells, hemostaseological examinations
(bleeding diathesis and/or thrombophilia), determining blood type
Digital classroom
Connecting microscopes of the classroom and visualizing the
images of the connected systems as overview; choosing single
images and sharing them with other students
Phase contrast: with this contrasting technique,
you can view high-contrast images of unstained samples.
You will be able to judge the cells’ growth, morphology,
and condition at a glance.
Oil immersion objectives: morphological examinations
of bacteria cells are carried out in brightfield when
studying microorganisms with an oil immersion objective.
Primo Star iLED: carry out fluorescence contrast examinations
of samples stained with FITC and Auramine O.
Primo Star with integrated HD camera and iPad imaging
app Labscope: connect your classroom and discuss samples
together.
6
ZEISS Primo Star at Work
› In Brief
›
The Advantages
›
The Applications
›
The System
›
Technology and Details
› Service
Fossil radiolarian, annular darkfield,
Objective: Plan-ACHROMAT 40x/0.65
Waterweed (Elodea), phase contrast,
Objective: Plan-ACHROMAT 40x/0.65
Flower umbel of daisy (Bellis perennis), brightfield,
Objective: Plan-ACHROMAT 10x/0.25
7
Your Flexible Choice of Components
›
In Brief
›
The Advantages
›
The Applications
›
The System
›
Technology and Details
4
5
1
2
› Service
4 Cameras
Recommended cameras:
• AxioCam ICc 5
3
• Axiocam 105 color
6
(requires ZEN 2012 SP2)
• AxioCam ICc 1
• AxioCam ERc 5s
• Tube with integrated 5 megapixel
HD streaming camera
1 Microscope
3 Illumination
5 Software
• Primo Star (Fixed-Köhler)
Transmitted light:
• ZEN lite
• Primo Star (Full Köhler)
• HAL 30 W (Halogen)
• iPad imaging app Labscope
• Primo Star iLED with reflected light
• LED 3 W
fluorescence illuminator
2 Objectives
• Plan-ACHROMAT 4x, 10x, 20x, 40x and 100x
• Illuminating mirror
6 Accessories
Reflected light:
• Transport case
• Reflected light fluorescence illuminator
• Battery supply unit
(455 nm, FS 67; 470 nm, FS 09)
for brightfield, darkfield and phase contrast
• Plan-ACHROMAT 100x/0.8 dry objective
• Plan-ACHROMAT 4x, 10x, 20x, 40x and 100x,
D=0 (without cover glass)
8
Your Flexible Choice of Components
›
In Brief
›
The Advantages
›
The Applications
›
The System
›
Technology and Details
1
2
Do you use the device in a laboratory (FOV 20 mm) or in a lecture hall?
Would you like to teach your students the Köhler illumination method or do you prefer a “Fixed-Köhler” device (FOV 18 mm) for the easiest possible use?
Easy-to-use Fixed-Köhler models (FOV 18 mm)
Do you want the stage drive on the right or left?
2 Full Köhler models for demanding educational and/or laboratory use (FOV 20 mm)
Which contrasting technique would you like to work with?
› Service
3 Stage drive left
3 Stage drive right
Would you like a 100x oil immersion
or 100x dry objective?
Standard
package
100×/1.25
oil immersion
objective
Package with
100×/0.8 dry
objective
3 Brightfield contrast
Would you like to document your work
with the device (phototube)?
Without
phototube
Package
Primo Star HD
With
phototube
with integrated
HD streaming
camera and optional
iPad imaging app
Labscope
3 Phase contrast
Would you like a complete system?
Phase package
with
Package with
objective
10x Ph1
20x Ph2
40x Ph2
100x Ph3
40× Ph2 and
phototube
Package 2
Package 1
Package 3
Package 6
Package 8
Package 7
Package 5
Package 4
415500-0052-000
415500-0051-000
415500-0053-000
415500-0056-000
415500-0059-000
415500-0057-000
415500-0055-000
415500-0054-000
Fluorescence attachment
415500-1823-001 (470 nm, filter set 09)
415500-1821-001 (455 nm, filter set 67)
Tube with integrated HD streaming camera
as option (415500-1402-000) and optional iPad imaging app Labscope
9
System Overview ZEISS Primo Star
›
In Brief
›
The Advantages
›
The Applications
›
The System
›
Technology and Details
Camera with C-mount
› Service
Compact Digital Camera
Camera adapter
P95-C 2/3" 0.65x
415500-1810-000
Camera adapter
P95-C 1/2" 0.5x
415500-1811-000
Camera with SLR-bayonet
Digital camera adapter
P95 M37/52x0.75
415500-1812-000
Camera adapter
P95-T2 DSLR 1.6x
415500-1825-000
Case for transport
and storage
for Primo Star and
Primo Star FL iLED
415500-1827-000
Diopter, d=30
444020-0000-000
Eyecup
Eyepiece WF 10x/18
Br. foc.
415500-1500-000
Eyepiece WF 10x/20
Br. foc.
415500-1501-000
Binocular tube 30°/20,
reversed image
415500-1400-000
Pointer for eyepiece foc.
415500-1806-000
Eyepiece micrometer
415500-1813-000
Reflected-light fluorescence
illuminator iLED
for Primo Star
415500-1821-001
or:
415500-1818-001
(special rate for high-burden
countries of TBC)
each of them including:
- LED module 455 nm
- FL reflector module with
filter set 67
- Yellow filter
Binocular phototube 30°/20
(50:50), reversed image
415500-1401-000
Primo Star LED microscope,
Fixed-Köhler, stage drive R, field 18, D=0
415500-0058-000
including:
- LED illumination
- 4-position nosepiece, tilted backwards
- Mechanical stage 75x30, drive right and specimen holder with spring clip left
- Binocular tube 30°/20
- Eyepieces 10x/18 Br. foc.
- Objectives Plan-Achromat D=0, without cover glass,
10x, 20x, 40x and 100x Oil
- Condenser 0.9/1.25
- External power unit 100...240 VAC/50...60 Hz/30 VA
with country-specific adapters
- Dust cover
- Oiler with 5 ml immersion oil
- Color filter set blue, green, yellow
equipped with:
Objective Plan-Achromat 10x/0.25 D=0; WD=4.6 mm
415500-1609-000
Objective Plan-Achromat 20x/0.4 D=0; WD=1.0 mm
415500-1610-000
Objective Plan-Achromat 40x/0.65 D=0; WD=0.72 mm
415500-1611-001
Objective Plan-Achromat 100x/1.25 oil D=0; WD=0.32 mm
incl. Immersion Oil for Primo, 5 ml
415500-1612-001
- Special eyecup
with light shield
415500-1819-000
- Magnetic field
transmitter
or:
415500-1823-001
including:
- LED module 470 nm
- FL reflector module with
filter set 09
- Yellow filter
- Special eyecup with light shield
- Magnetic field transmitter
Primo Star iLED package
415500-0040-001
consisting of:
415500-0058-000 and 415500-1818-001
or 415500-1818-000
for high burden countries
according to WHO definition
Binocular tube 30°/20,
integrated camera for Primo Star
415500-1402-000
For Fixed-Köhler only:
Attachable
transmitted-light
mirror
415500-1202-000
also available:
Objective Plan-Achromat 4x/0.10; WD=12.0 mm
415500-1600-001
Objective Plan-Achromat 10x/0.25; WD=4.4 mm
415500-1601-002
Objective Plan-Achromat 10x/0.25 Ph 1; WD=4.6 mm
415500-1605-001
Objective Plan-Achromat 20x/0.40; WD=0.90 mm
415500-1606-000
Objective Plan-Achromat 20x/0.40 Ph 2; WD=0.90 mm
415500-1607-000
Objective Plan-Achromat 40x/0.65; WD=0.61 mm
415500-1602-001
Objective Plan-Achromat 40x/0.65 Ph 2; WD=0.61 mm
415500-1603-001
Objective Plan-Achromat 100x/0.8 dry; WD=0.94 mm
415500-1620-000
Objective Plan-Achromat 100x/1.25 oil; WD=0.21 mm
incl. Immersion Oil for Primo, 5 ml
415500-1604-001
Objective Plan-Achromat 100x/1.25 oil, Ph 3; WD=0.21 mm
incl. Immersion Oil for Primo, 5 ml
415500-1608-000
Case for transport
and storage
415500-1805-000
(not suitable for Primo Star iLED)
For Primo Star and Primo Star LED microscopes:
Battery supply unit
415500-1814-000
For Full Köhler only:
Slider Ph 1, for Primo Star
415500-1815-000
Slider Ph 2, for Primo Star
415500-1803-000
Slider Ph 3, for Primo Star
415500-1817-000
Darkfield slider
0.40-0.65
415500-1802-000
For Full-Köhler only:
Slider Ph 1, H, Ph 2
for Primo Star
415500-1816-000
Slider H,
Ph 1, Ph 2, Ph 3
for Primo Star
415500-1826-000
Color filter set
blue, green, yellow,
d=45x1.5
415500-1804-000
Primo Star microscope stand, Fixed-Köhler, R
415500-1100-000
required:
Abbe condenser 0.9/1.25 field 18, Fixed-Köhler
415500-1701-000
Mechanical stage 75x30, drive right
415500-1300-000
Specimen holder left, for mechanical stage
415500-1302-000
Primo Star microscope stand, Fixed-Köhler, L
415500-1102-000
required:
Abbe condenser 0.9/1.25 field 18, Fixed-Köhler
415500-1701-000
Mechanical stage 75x30, drive left
415500-1301-000
Specimen holder left, for mechanical stage
415500-1302-000
Primo Star microscope stand, Full-Köhler, R
415500-1101-000
required:
Abbe condenser 0.9/1.25 field 20, Full-Köhler
415500-1700-000
Mechanical stage 75x30, drive right
415500-1300-000
Specimen holder left, for mechanical stage
415500-1302-000
Primo Star microscope stand, Full-Köhler, L
415500-1103-000
required:
Abbe condenser 0.9/1.25 field 20, Full-Köhler
415500-1700-000
Mechanical stage 75x30, drive left
415500-1301-000
Specimen holder left, for mechanical stage
415500-1302-000
Transmitted-light illuminator with LED warm light
for Primo Star and Primo Star iLED
415500-1200-001
Transmitted-light illuminator with HAL for Primo Star
415500-1201-001
Halogen lamp 6 V 30 W
415500-1901-000
10
Technical Specifications
›
In Brief
›
The Advantages
›
The Applications
›
The System
›
Technology and Details
› Service
Dimensions (width x depth x height)
Stand with binocular tube
approx. 190 mm x 410 mm x 395 mm
Stand with phototube
approx. 190 mm x 425 mm x 395 mm
Stand with binocular tube 30°/20
and integrated HD IP camera for Primo Star
approx. 190 mm x 415 mm x 395 mm
With tube / phototube turned by 180°
approx. 190 mm x 375 mm x 395 mm
Stand with reflected-light fluorescence illuminator
approx. 190 mm x 410 mm x 449 mm
Weight
Primo Star with phototube
approx. 8.2 kg
Primo Star iLED with reflected-light
fluorescence illuminator and phototube
approx. 9.6 kg
Primo Star with internal HD streaming camera
approx. 8.5 kg
11
Technical Specifications
›
In Brief
›
The Advantages
›
The Applications
›
The System
›
Technology and Details
› Service
Ambient conditions
Transportation (in packaging):
Permissible ambient temperature
-40 °C to +70 °C
Storage:
Permissible ambient temperature
+10 °C to +40 °C
Permissible air humidity (no condensation)
max. 75 % at 35 °C
Operation:
Permissible ambient temperature
+10 °C to +40 °C
Permissible air humidity (no condensation)
max. 75 % at 35 °C
Atmospheric pressure
800 hPa to 1060 hPa
Altitude
max. 2000 m
Operating data
Protection class
II
Protection type
IP20
Electrical safety
in compliance with DIN EN 61010-1 (IEC 61010-1) including CSA and UL directives
Pollution degree
2
Overvoltage category
II
Radio interference suppression
in accordance with EN 61326
Line voltage
100 to 240 V (±10 %) wide-range input power supply,
i.e. voltage setting of the instrument need not be changed!
Line frequency
50 / 60 Hz
Power consumption
70 VA; secondary voltage of external power supply 12 V
Plug-in power unit output
12 V DC; max. 2.5 A
Microscope 12 V / 6 V DC
adjustable from 1.5 V to 6 V
LED class of complete device
3B
12
Technical Specifications
›
In Brief
›
The Advantages
›
The Applications
›
The System
›
Technology and Details
› Service
Light sources
Halogen lamp
HAL 6 V, 30 W
Adjustability of light source
continuous, from 1.5 to 6 V DC
Color temperature at 6 V
2800 K
Luminous flux
280 lm
Average service life
1000 h
Luminous area
1.5 x 3 mm
LED illumination
white light LED, peak wavelength 440 nm, LED class 2
Constant, brightness-independent color temperature of
3200 K
Homogeneous field illumination
20 mm diameter
Suitable for objectives with magnifications of
4x to 100x
Analogous brightness adjustment from
approx. 15 to 100 %
LED modules (reflected light fluorescence illuminator)
max. 40 mW, 365 - 625 nm; LED class 3B
Battery supply unit (accessory)
Batteries
fuses according to IEC 127 T4.0 A/H
Type
mono-cell (D) - commercially available, NiCd or NiMH, 1.2 V
Capacity
minimum 5000 to max. 9000 mAh
Number per battery supply unit
5 batteries
Operational lifetime
several hours, depending on the capacity of the batteries
13
Technical Specifications
›
In Brief
›
The Advantages
›
The Applications
›
The System
›
Technology and Details
› Service
Optical/mechanical data
Stand with stage focusing
With coarse focusing drive
45 mm/rev.
With fine focusing drive
0.5 mm/rev.
Total stage lift
15 mm
Objective change
manual via quadruple objective nosepiece
Objectives
infinity-corrected objective range with W 0.8 mounting thread
Eyepieces
30 mm tube size
With field-of-view number 18
PL 10x/18 Br. foc.
With field-of-view number 20
PL 10x/20 Br. foc.
Specimen stage
mechanical stage 75x30 right/left
Dimensions (width x depth)
140 x 135 mm
Stage travel (X x Y)
75 x 30 mm
Coaxial drive
optionally right or left
Vernier scales
readable from the right
Specimen holder
with spring lever, left
Abbe condenser 0.9/1.25; Fixed-Köhler
for Vobj. 4x to 100x
Abbe condenser 0.9/1.25; Full Köhler
for Vobj. 4x to 100x
Binocular tube 30°/20
Maximum field-of-view number
20
Interpupillary distance
adjustable from 48 to 75 mm
Tube angle
30°
Viewing height
380 to 415 mm
Viewing port
tube factor 1x
Binocular phototube 30°/20
Maximum field-of-view number
20
Interpupillary distance
adjustable from 48 to 75 mm
Tube angle
30°
Viewing height
380 to 415 mm
Viewing port
tube factor 1x
Photo/video port
tube factor 1x, 60 mm mount
Invariable splitting ratio
50 % vis / 50 % doc
14
Technical Specifications
›
In Brief
›
The Advantages
›
The Applications
›
The System
›
Technology and Details
› Service
Binocular tube 30°/20
with integrated HD IP camera for Primo Star
Maximum field-of-view number (eyepiece)
20
Captured field-of-view of the camera
11.4 mm x 8.56 mm (14.2 mm diagonal)
Interpupillary distance
adjustable from 48 to 75 mm
Tube angle
30°
Viewing height
380 mm to 415 mm
Invariable splitting ratio
50 % vis / 50 % doc
Optical adaption
0.5x
Illuminating mirror
with plane surface and spherical surface with f' = 75 mm
HD-CMOS-camera
Sensor specific data
Sensor
Micron MT9P031
Sensor size
1/2.5", 5.7 mm x 4.28 mm (7.1 mm diagonal)
Pixel size
2.2 μm x 2.2 μm
Sensor type
1/2.5" CMOS, color
Read-out mode
Progressive scan
Sensor pixel count (H x V), full frame
2560 x 1920 pixel active, 5 megapixel
Live image, movie
1920 x 1080 pixel, 30Fps (H264 max. 16 MBits / s)
Spectral sensitivity (without IR filter)
400 nm to 700 nm
Signal-Processing / Interface specific data
Digitalzation / Color depth
24 Bit, 3 x 8 Bit / pixel
Amplifying
0-18 dB
Interfaces
USB 2.0, Mini-USB-plug
LAN via RJ 45 plug socket, 100 Mbit
SD-card (Secure Digital) 1-32 GB, slot for SD and SDHC
HDMI (1080p/30 or 720p/60)
Remote control
IR sensor
Duo LED
Power on and ready for capture (green); Recording (blinking green); Not ready (red); Error (blinking red)
Key matrix
White balance, Snap, Contrast, Brightness, Menu
Exposure time
10 µs to 2 s
15
Technical Specifications
›
In Brief
›
The Advantages
›
The Applications
›
The System
›
Technology and Details
› Service
General
Power supply
Via USB hub or external power supply, 5 V DC, power consumption 5 W
Ambient conditions (operation)
+5 °C to +45 °C, max. 80 % relative humidity, no condensation
Operating data of power supply unit
for binocular tube 30°/20
with integrated HD IP camera for Primo Star
Protection class
II
Protection type
IP20
Electrical safety
Via USB hub or external power supply, 5 V DC, power consumption 5 W
Pollution degree
2
Overvoltage category
II
Radio interference suppression
in accordance with EN 61326-1 and EN 61326-2-6
Line voltage
100 to 240 V (±10 %) wide-range input power supply,
i.e. voltage setting of the instrument need not be changed!
Line frequency
50 / 60 Hz
Power consumption plug-in power unit output
5 V DC, 1.0 A
16
Count on Service in the True Sense of the Word
›
In Brief
›
The Advantages
›
The Applications
Because the ZEISS microscope system is one of your most important tools, we make sure it is always ready
to perform. What’s more, we’ll see to it that you are employing all the options that get the best from your
microscope. You can choose from a range of service products, each delivered by highly qualified ZEISS
specialists who will support you long beyond the purchase of your system. Our aim is to enable you to
experience those special moments that inspire your work.
› The System
›
Technology and Details
›
Service
Repair. Maintain. Optimize.
Attain maximum uptime with your microscope. A ZEISS Protect Service Agreement lets you budget for
operating costs, all the while reducing costly downtime and achieving the best results through the improved
performance of your system. Choose from service agreements designed to give you a range of options and
control levels. We’ll work with you to select the service program that addresses your system needs and
usage requirements, in line with your organization’s standard practices.
Our service on-demand also brings you distinct advantages. ZEISS service staff will analyze issues at hand
and resolve them – whether using remote maintenance software or working on site.
Enhance Your Microscope System.
Your ZEISS microscope system is designed for a variety of updates: open interfaces allow you to maintain
a high technological level at all times. As a result you’ll work more efficiently now, while extending the
productive lifetime of your microscope as new update possibilities come on stream.
Please note that our service products are always being adjusted to meet market needs and maybe be subject
to change.
Profit from the optimized performance of your microscope
system with services from ZEISS – now and for years to come.
>> www.zeiss.com/microservice
17
Carl Zeiss Microscopy GmbH
07745 Jena, Germany
microscopy@zeiss.com
www.zeiss.com/primostar
EN_41_011_042 | CZ 03-2014 | Design, scope of delivery and technical progress subject to change without notice. | © Carl Zeiss Microscopy GmbH
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertising