ABB water/wastewater drives ACQ550, 1 to 550 HP
ABB water/wastewater drives
ACQ550, 1 to 550 HP
A reliable system is critical
to protecting, supplying
and recycling water. What
you choose matters. The
world trusts you to make
good decisions and you
take that responsibility
seriously. We’ll help
safeguard your system to
TWPGHƂEKGPVN[CPFRTQXKFG
the value and dependability
you demand.
With this in mind, we designed our variable
speed AC drives specifically for Water/
Wastewater environments and applications.
These devices are available, as standard, for
panel-mounting or factory direct NEMA-1,
drip-proof NEMA-12 or outdoor-rated
NEMA-3R enclosures.
A water industry start-up assistant resides
within the intuitive, full graphic display panel to
aid in commissioning submersible, centrifugal
or positive displacement pumps. This control
panel can also be mounted remotely, or on
the cover of the drive, and used to upload,
store and download parameters in multiple
drive setups.
troubleshooting, the drive uses a realtime clock, which allows for accurate
time stamps on faults, resets and more.
Two integral option slots, that can be
configured for additional relay outputs (i.e.
drive status indications, timed or pump
staging applications) or a variety of different
communication bus adapters, are at your
disposal.
Cost savings
applications, the power requirement of the
pump varies by the cube of the speed.
Electronically reducing the pump speed by
20% will typically cut energy costs in half.
Designed for water
The ACQ550 - which ranges from 1 to 550
HP - is well-suited to meet your needs, from
the simplest pumping applications, through
the most demanding.
We designed our solutions to give you the
most flexible motor control performance
through two standard modes: Scalar (V/Hz)
for typical pumps and Sensorless Vector for
the more demanding applications. Through
either of these, you will have accurate speed
control of any standard induction motor.
Application control
Save energy by applying variable electronic
speed control to your pumps and pumping
systems. These savings can be achieved
The extensive library of pre-programmed,
water-specific application macros allows
rapid configuration of inputs, outputs, and
parameters to maximize convenience and
minimize start-up time. To simplify
over bypass or valve-operated flow control,
traditional diesel driven systems or across the
line operations. The Affinity Laws of physics
define the relationship between pumps and
the power they require. On centrifugal pump
ACQ550-PHPB01U-EN REV C 05/25/2014
System reliability, pump efficiency and a
suite of industry-specific controls enable
you to successfully maintain a reliable
water cycle management system.
Technical data
ACQ550 standard drives
Option modules
ACQ550-U1 wall mount
Available enclosures
DeviceNet
NEMA 1 & 12 Enclosures for 1.5 - 200 Hp
PROFIBUS-DP
ACQ550-CC bypass
Available enclosures
ControlNet
NEMA 1, 12 and 3R Enclosures for 1.5 - 200 Hp
Fieldbus adapters
Main input disconnect
Two Contactor Bypass with circuit breaker
disconnect (CC)
ACQ550-PC/PD with circuit breaker or disconnect
Available enclosures
Main input disconnect
NEMA 1 for 1.5 - 400 Hp, NEMA 12 for 1.5 - 550 Hp,
NEMA 3R for 1.5 - 200 Hp Enclosures
Circuit Breaker (PC)
Disconnect Switch (PD)
Input power connection
Voltage and power range
Frequency
Power factor
3-phase, 208 to 240 V, +10/-15%, 1 - 100 Hp
3-phase, 380 to 480 V, +10/-15%, 1 - 550 Hp
3-phase, 500 to 600 V, +10/-15%, 1.5 - 150 Hp
48 to 63 Hz
0.98
PROFINET IO
Additional modules
Maximum switching capacity
Maximum continuous
8 A/24 VDC or 250 VAC; 0.4 A/120 VDC
Ic = 2 A RMS
8OCZMŝVQMŝ
Product compliance
240 V, 480 V, 600 V products
0 (4) to 20 mA, load < 500 ŝ±3%
24 V DC ±10%, max. 250 mA (short circuit protected)
12 to 24 V DC with internal or external supply, PNP and NPN
Environmental limits
Protection class
Ambient temperature
Relative humidity
UL Type 1 , 12 or 3R (NEMA 1 , NEMA 12, NEMA 3R)
-5 to 40oC (5 to 104oF)
40 to 50oC (104 to 122oF) with derate
No frost allowed
fswitch 4 kHz, PN and I2 derated to 90%
Lower than 95% (without condensation)
For more information please contact your local ABB representative or visit:
www.abb.com/drives
www.abb.com/water
Frequency 0 to 500 Hz
0.1 to 1800 s
0.1 to 1800 s
Serial communication built in as standard
Embedded building automation
protocols
Programmable control connection
0 (2) to 10 V, Rin > 250 kŝ single-ended
0 (4) to 20 mA, Rin = 100 ŝ single-ended
Panel mounting kits
Relay output extension module
Flange mounting kits
Output (motor) connection
Frequency
Acceleration time
Deceleration time
Two analog inputs
Voltage signal
Current signal
Potentiometer
reference value
Two analog outputs
Auxiliary voltage
Six digital inputs
Three relay outputs
CANopen
Ethernet (EIP,MB/TCP,PROFINET)
EtherCat adapter
NEMA 1 & 12 Free Standing for 250 - 400 Hp
RS 485
Modbus RTU protocol
UL, cUL, CSA, CE, C-TICK, and
GOST-R approvals
Low Voltage Directive 73/23/EEC with
supplements
Machinery Directive 98/37/EC
EMC Directive 89/336/EEC with
supplements
Quality assurance system ISO 9001 and
Environmental system ISO 140001
© Copyright 2014 ABB. All rights reserved
Specifications subject to change without notice.
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project