Universal V2 Rack - Hitachi Data Systems
Hitachi Universal V2 Rack
Reference Guide
Hitachi Virtual Storage Platform G200, G400, G600, G800
Hitachi Virtual Storage Platform F400, F600, F800
Hitachi Virtual Storage Platform G1000
MK-94HM8035-04
May 2016
© 2015 Hitachi, Ltd. All rights reserved.
No part of this publication may be reproduced or transmitted in any form or by any means, electronic
or mechanical, including copying and recording, or stored in a database or retrieval system for
commercial purposes without the express written permission of Hitachi, Ltd., or Hitachi Data Systems
Corporation (collectively “Hitachi”). Licensee may make copies of the Materials provided that any such
copy is: (i) created as an essential step in utilization of the Software as licensed and is used in no
other manner; or (ii) used for archival purposes. Licensee may not make any other copies of the
Materials. “Materials” mean text, data, photographs, graphics, audio, video and documents.
Hitachi reserves the right to make changes to this Material at any time without notice and assumes
no responsibility for its use. The Materials contain the most current information available at the time
of publication.
Some of the features described in the Materials might not be currently available. Refer to the most
recent product announcement for information about feature and product availability, or contact
Hitachi Data Systems Corporation at https://support.hds.com/en_us/contact-us.html.
Notice: Hitachi products and services can be ordered only under the terms and conditions of the
applicable Hitachi agreements. The use of Hitachi products is governed by the terms of your
agreements with Hitachi Data Systems Corporation.
By using this software, you agree that you are responsible for:
1. Acquiring the relevant consents as may be required under local privacy laws or otherwise from
authorized employees and other individuals to access relevant data; and
2. Verifying that data continues to be held, retrieved, deleted, or otherwise processed in
accordance with relevant laws.
Notice on Export Controls. The technical data and technology inherent in this Document may be
subject to U.S. export control laws, including the U.S. Export Administration Act and its associated
regulations, and may be subject to export or import regulations in other countries. Reader agrees to
comply strictly with all such regulations and acknowledges that Reader has the responsibility to obtain
licenses to export, re-export, or import the Document and any Compliant Products.
Hitachi is a registered trademark of Hitachi, Ltd., in the United States and other countries.
AIX, AS/400e, DB2, Domino, DS6000, DS8000, Enterprise Storage Server, eServer, FICON,
FlashCopy, IBM, Lotus, MVS, OS/390, PowerPC, RS/6000, S/390, System z9, System z10, Tivoli,
z/OS, z9, z10, z13, z/VM, and z/VSE are registered trademarks or trademarks of International
Business Machines Corporation.
Active Directory, ActiveX, Bing, Excel, Hyper-V, Internet Explorer, the Internet Explorer logo,
Microsoft, the Microsoft Corporate Logo, MS-DOS, Outlook, PowerPoint, SharePoint, Silverlight,
SmartScreen, SQL Server, Visual Basic, Visual C++, Visual Studio, Windows, the Windows logo,
Windows Azure, Windows PowerShell, Windows Server, the Windows start button, and Windows Vista
are registered trademarks or trademarks of Microsoft Corporation. Microsoft product screen shots are
reprinted with permission from Microsoft Corporation.
iPad is a trademark of Apple Inc., registered in the U.S. and other countries.
All other trademarks, service marks, and company names in this document or website are properties
of their respective owners.
Equipment warranty
The term of guarantee of normal operation of the storage system and free service is one year from
date of purchase.
If a failure occurs multiple times, the storage system might shut off to avoid a serious accident.
Backup
Hitachi cannot guarantee against data loss due to failures. Therefore, back up your data to minimize
chances for data loss.
Data backup is also critical when hardware components are added or replaced, because performing
such hardware procedures restores parameter settings that can affect how data is managed on the
storage systems.
Disposal
2
Hitachi Universal V2 Rack Reference Guide for Hitachi Virtual Storage Platform G Series and F Series
This symbol on the product or on its packaging means that your electrical and electronic equipment should be
disposed at the end of life separately from your household wastes.
There are separate collection systems for recycling in the European Union. For more information, contact the
local authority or the dealer where you purchased the product.
UEFI Development Kit 2010
This product includes UEFI Development Kit 2010 written by the UEFI Open Source Community. For more
information, see the UEFI Development Kit website:
http://sourceforge.net/apps/mediawiki/tianocore/index.php?title=UDK2010
© 2004, Intel Corporation.
All rights reserved.
Redistribution and use in source and binary forms, with or without modification, are permitted provided that the
following conditions are met:
Redistributions of source code must retain the above copyright notice, this list of conditions and the following
disclaimer.
Redistributions in binary form must reproduce the above copyright notice, this list of conditions and the
following disclaimer in the documentation and/or other materials provided with the distribution.
Neither the name of the Intel Corporation nor the names of its contributors might be used to endorse or
promote products derived from this software without specific prior written permission.
THIS SOFTWARE IS PROVIDED BY THE COPYRIGHT HOLDERS AND CONTRIBUTORS “AS IS” AND ANY EXPRESS
OR IMPLIED WARRANTIES, INCLUDING, BUT NOT LIMITED TO, THE IMPLIED WARRANTIES OF
MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE ARE DISCLAIMED. IN NO EVENT SHALL THE
COPYRIGHT OWNER OR CONTRIBUTORS BE LIABLE FOR ANY DIRECT, INDIRECT, INCIDENTAL, SPECIAL,
EXEMPLARY, OR CONSEQUENTIAL DAMAGES (INCLUDING, BUT NOT LIMITED TO, PROCUREMENT OF
SUBSTITUTE GOODS OR SERVICES; LOSS OF USE, DATA, OR PROFITS; OR BUSINESS INTERRUPTION)
HOWEVER CAUSED AND ON ANY THEORY OF LIABILITY, WHETHER IN CONTRACT, STRICT LIABILITY, OR TORT
(INCLUDING NEGLIGENCE OR OTHERWISE) ARISING IN ANY WAY OUT OF THE USE OF THIS SOFTWARE, EVEN
IF ADVISED OF THE POSSIBILITY OF SUCH DAMAGE.
3
Hitachi Universal V2 Rack Reference Guide for Hitachi Virtual Storage Platform G Series and F Series
4
Hitachi Universal V2 Rack Reference Guide for Hitachi Virtual Storage Platform G Series and F Series
Contents
Preface................................................................................................. 7
Intended audience................................................................................................... 8
Safety guidelines......................................................................................................8
Release notes.......................................................................................................... 9
Changes in this revision............................................................................................9
Related documents.................................................................................................. 9
Accessing product documentation............................................................................. 9
Getting help...........................................................................................................10
Comments............................................................................................................. 10
1
Universal V2 Rack.......................................................................... 11
About the Hitachi Universal V2 Rack........................................................................ 12
Rack specifications................................................................................................. 12
Power distribution units (PDUs)............................................................................... 15
PDU specifications............................................................................................ 16
PDU plugs........................................................................................................ 17
Rail kits................................................................................................................. 18
Rack accessories.................................................................................................... 18
Dense intermix drive tray considerations.................................................................. 19
Third-party racks....................................................................................................19
Third-party racks for VSP G200, G400, G600, G800 and VSP F400, F600, F800..... 19
Third-party racks for VSP G1000........................................................................ 20
Index..................................................................................................21
5
Hitachi Universal V2 Rack Reference Guide for Hitachi Virtual Storage Platform G Series and F Series
6
Hitachi Universal V2 Rack Reference Guide for Hitachi Virtual Storage Platform G Series and F Series
Preface
This document provides descriptions and specifications for the Universal V2
Rack for the following Hitachi storage systems:
• Hitachi Virtual Storage Platform G200, G400, G600, G800
• Hitachi Virtual Storage Platform F400, F600, F800
• Hitachi Virtual Storage Platform G1000
Information for supported power distribution units, rail kits, and accessories
is included.
For information about mounting Hitachi storage systems in third-party racks,
see the Hitachi Virtual Storage Platform Site Preparation Guide
(MK-94HM8034) and the appropriate Hitachi Virtual Storage Platform
Hardware Reference Guide.
□ Intended audience
□ Safety guidelines
□ Release notes
□ Changes in this revision
□ Related documents
□ Accessing product documentation
□ Getting help
□ Comments
Preface
Hitachi Universal V2 Rack Reference Guide for Hitachi Virtual Storage Platform G Series and F Series
7
Intended audience
This document is provided for owners, administrators, and operators of the
following storage systems:
• Hitachi Virtual Storage Platform G200, G400, G600, G800
• Hitachi Virtual Storage Platform F400, F600, F800
• Hitachi Virtual Storage Platform G1000
Safety guidelines
Read and follow all safety guidelines and procedures.
• All activities must be performed by trained and qualified engineers only.
Adhere to the following general guidelines.
○ Hazard warnings on the rack and storage systems are provided to aid
you in preventing or reducing the risk of death, personal injury, or
product damage. Understand and follow these hazard warnings fully.
○ When lifting a heavy object, hold it close to yourself and keep your back
erect to prevent back injury.
○ If an unusual noise, smell, or smoke occurs on the storage system while
it is running, power off or remove the power cables immediately.
○ Do not use materials that are outside the specifications for the rack or
storage systems.
○ Keep the maintenance area neat.
○ Always put away parts, materials, and tools when not in use.
• Prevent electric shock by adhereing to the following:
○ Before starting work, be sure that, unless otherwise specifically
instructed, there is no potential electric hazard in the area such as
insufficient grounding or a wet floor.
○ Before starting work, know where the emergency power-off switches
are located and be sure you know how to operate them.
○ Unless otherwise specifically instructed, remove all power sources to the
power distribution unit (PDU) before starting maintenance. Switching off
the storage system power supplies is usually not sufficient.
○ Do not touch any uninsulated conductor or surface that remains
charged for a limited time after the external power supply to the
storage system is disconnected.
○ Do not replace parts during a thunderstorm.
• In case of electric shock:
○ Unless otherwise instructed, remove all power sources to the storage
system. Switching off the storage system power supplies is not
sufficient. When power is fed from a wall or floor outlet, unplug the
power supply cord, or turn off the switch on the PDU or board.
8
Preface
Hitachi Universal V2 Rack Reference Guide for Hitachi Virtual Storage Platform G Series and F Series
○ If the power supply has a lockout device, lock the device after powering
off the storage system and retain the key. Attach a notice on the panel
or board prohibiting the use of the switch.
• In case of fire:
○ Shut off all the power to storage systems.
○ Turn off the emergency power switch or stop the power supply to
storage systems.
○ If the fire continues to burn after the power is shut off, take suitable
actions, including the use of a fire extinguisher, or call the fire
department.
Release notes
Read the release notes before installing and using this product. They may
contain requirements or restrictions that are not fully described in this
document or updates or corrections to this document. Release notes are
available on Hitachi Data Systems Support Connect: https://
support.hds.com/en_us/documents.html.
Changes in this revision
• Revised the figure of the EMEA/APAC PDUs to show the proper
silkscreening.
Related documents
• Hitachi Virtual Storage
MK-94HM8020
• Hitachi Virtual Storage
MK-94HM8022
• Hitachi Virtual Storage
MK-94HM8026
• Hitachi Virtual Storage
MK-94HM8045
• Hitachi Virtual Storage
MK-94HM8046
• Hitachi Virtual Storage
Platform G200 Hardware Reference Guide,
Platform G400, G600 Hardware Reference Guide,
Platform G800 Hardware Reference Guide,
Platform F400, F600 Hardware Reference Guide,
Platform F800 Hardware Reference Guide,
Platform G1000 Hardware Guide, MK-92RD8007
Accessing product documentation
Product user documentation is available on Hitachi Data Systems Support
Connect: https://support.hds.com/en_us/documents.html. Check this site for
Preface
Hitachi Universal V2 Rack Reference Guide for Hitachi Virtual Storage Platform G Series and F Series
9
the most current documentation, including important updates that may have
been made after the release of the product.
Getting help
Hitachi Data Systems Support Connect is the destination for technical support
of products and solutions sold by Hitachi Data Systems. To contact technical
support, log on to Hitachi Data Systems Support Connect for contact
information: https://support.hds.com/en_us/contact-us.html.
Hitachi Data Systems Community is a global online community for HDS
customers, partners, independent software vendors, employees, and
prospects. It is the destination to get answers, discover insights, and make
connections. Join the conversation today! Go to community.hds.com,
register, and complete your profile.
Comments
Please send us your comments on this document to doc.comments@hds.com.
Include the document title and number, including the revision level (for
example, -07), and refer to specific sections and paragraphs whenever
possible. All comments become the property of Hitachi Data Systems
Corporation.
Thank you!
10
Preface
Hitachi Universal V2 Rack Reference Guide for Hitachi Virtual Storage Platform G Series and F Series
1
Universal V2 Rack
This chapter provides descriptions and specifications for the A3BF-600-1200v2 rack. Information for supported power distribution units (PDUs), rail kits,
and accessories is provided.
□ About the Hitachi Universal V2 Rack
□ Rack specifications
□ Power distribution units (PDUs)
□ Rail kits
□ Rack accessories
□ Dense intermix drive tray considerations
□ Third-party racks
Universal V2 Rack
Hitachi Universal V2 Rack Reference Guide for Hitachi Virtual Storage Platform G Series and F Series
11
About the Hitachi Universal V2 Rack
The Hitachi Universal V2 Rack can be used to mount VSP G200, G400, G600,
G800; VSP F400, F600, F800; and VSP G1000 controller trays and one or
more drive trays The following figure shows views of the Hitachi rack.
Figure 1 Hitachi Universal V2 Rack
Rack specifications
Rack specifications for VSP G200, G400, G600, G800; VSP F400, F600, F800;
and VSP G1000 storage systems are provided in the following tables.
Note: Customer-supplied racks that have the same specifications as the
Hitachi 600-1200-V2 rack can also be used to mount VSP G200, G400, G600,
12
Universal V2 Rack
Hitachi Universal V2 Rack Reference Guide for Hitachi Virtual Storage Platform G Series and F Series
G800; VSP F400, F600, F800; and VSP G1000 storage systems. Contact your
Hitachi Data Systems representative for details.
Table 1 Basic A3BF-600-1200-V2 specifications
Product code
A3BF-600-1200-V2
Description
•
•
Black locking back door
External Dimensions (with panels)
○ Width: 600 mm (23 62 in) - see note 3 below
○ Depth: 1200 mm (47.24 in)
○ Height: 2008 mm (79.05 in)
○ Mounting height for storage equipment: 42U (2008 mm)
Rail kits, PDUs, and power cords must be ordered separately.
Table 2 Detailed A3BF-600-1200-V2 specifications
Item
Specification
P-code
A3BF-600-1200-V2
Dimensions (width x
depth x height)
•
•
600 x 1200 x 2008 mm - see note 3 below
(23.62 in x 47.24 in x 79.05 in)
Weight
•
•
•
139 kg/306 lb 7.0811 oz (includes side panels)
1050 kg/2314 lb 13.663 oz static weight capacity1
500 kg/1102 lb 4.9824 oz dynamic weight capacity2
Frame
•
•
•
•
•
Height: 42U (2008 mm)
Finished black (RAL 9011) with Hitachi logo and label
1 set grounding cables (earthing cable)
36 1U filler panels
1 cover set, front (left, right, and bottom)
Base
•
•
•
4 adjustable base legs (leveling feet)
2 wheels, front
2 casters, back
Roof
2 brush cut-outs, left and right
Rear
•
•
•
•
•
•
1
3
1
1
1
1
Accessories (separate
box)
•
•
•
•
•
•
•
•
•
•
•
1 anti-tilt cabinet stabilizer - 600 mm (width)
1 universal wrench for leveling feet
40 velcro straps
100 T-wraps - 360 x 4.8 mm (black)
100 cage nuts M5
100 screws M5 (black)
8 screws M5 x 8 (spare parts)
8 screws M6 x 12 (spare parts)
1 nylon strap
8 mounting brackets for PDUs (includes mounting material)
2 plinths, front and rear - 600 mm (width)
door, 65% ventilated - 600 mm x 42U (width x height)
hinges, right side
swivel handle
lock for swivel handle, EK-1333 (keys in zip bag)
laptop shelf
door stopper
Universal V2 Rack
Hitachi Universal V2 Rack Reference Guide for Hitachi Virtual Storage Platform G Series and F Series
13
Item
Specification
•
1 baying kit (4 pieces, includes mounting material)
Notes:
1. Static weight capacity is the maximum weight the rack can support after it has been properly
leveled and installed (fitted with stabilizers or secured to other equipment).
2. Dynamic weight capacity is the maximum weight the rack can support while being shipped or
moved with equipment installed.
3. Installing the optional cover set extends the rack width to 603 mm (23.74 in).
The following shows the rack dimension with the optional cover set not
installed.
14
Universal V2 Rack
Hitachi Universal V2 Rack Reference Guide for Hitachi Virtual Storage Platform G Series and F Series
Power distribution units (PDUs)
The Hitachi Universal V2 Rack is configured with power distribution units
(PDUs), which power the components placed in the rack. Input power to the
PDUs, which varies with location, is either single phase or three phase.
The following figures show Hitachi PDUs used in the Universal V2 Rack in the
Americas and in APAC / EMEA. The types of plugs used in the PDUs are
discussed in PDU plugs on page 17.
Figure 2 Americas PDUs for the Universal V2 Rack
Universal V2 Rack
Hitachi Universal V2 Rack Reference Guide for Hitachi Virtual Storage Platform G Series and F Series
15
Figure 3 APAC / EMEA PDUs for the Universal V2 Rack
Note: Physical compatibility between the Universal V2 Rack and third party
PDUs is best effort only.
Make sure to review electrical specifications in your storage system
installation guide. Do not exceed the maximum usable amperage per PDU to
reduce risk of injury, fire, or damage to equipment. Consult the electrical
authority for your facility's wiring and installation requirements. The following
basic requirements also apply:
• Before installing third-party components in the rack, determine the current
draw of each component and compare that with the allowable current load
on each PDU to determine whether the component can be plugged into a
PDU.
• Balance the current load between available PDUs.
PDU specifications
The following table shows PDU specifications for the Universal V2 Rack. All
specifications apply for the VSP G200, G400, G600, G800; VSP F400, F600,
F800; and VSP G1000 storage systems.
Table 3 Basic PDU specifications
Specification
Item
Americas
Single phase
PDU-121112F10
16
•
•
•
30A, 208V
12 IEC 320-C13 outlets
NEMA L6-30P connector
Universal V2 Rack
Hitachi Universal V2 Rack Reference Guide for Hitachi Virtual Storage Platform G Series and F Series
Item
Three phase (default)
PDU-32C13800F10
Three phase (high-density
configurations as prompted by
the Configurator)
PDU-121132F10
Specification
•
10-foot power cable
•
•
•
•
•
30A, 208V
26 IEC 320-C13 outlets
6 IEC 320-C19 outlets
NEMA L15-30P connector
10-foot power cable
•
•
•
•
30A, 208V
12 IEC 320-C13 outlets
NEMA L15-30P connector
10-foot power cable
•
•
•
•
•
32A, 230V
12 IEC 320-C13 outlets
2 IEC 320-C19 outlets
IEC-309 blue 2P+E connector
15-foot (4.5 m) power cable
•
•
•
•
•
32A, 400V
24 IEC 320-C13 outlets
6 IEC 320-C19 outlets
IEC-309 red 4P+E connector
15-foot (4.5 m) power cable
APAC and EMEA
Single phase
A3CR-123294-51
Three phase
A3CK-243694-50
PDU plugs
The following figure shows the PDU plug types that are used with the
Universal V2 Rack.
Figure 4 PDU plugs
Universal V2 Rack
Hitachi Universal V2 Rack Reference Guide for Hitachi Virtual Storage Platform G Series and F Series
17
• Plug #1 is for single phase use in the Americas, including the United
States and Canada.
• Plug #2 is for three phase use in the Americas, including the United States
and Canada.
• Plug #3 is for single phase use in Asia-Pacific and Europe-Middle EastAfrica.
• Plug #4 is for three phase use in Asia-Pacific and Europe-Middle EastAfrica.
Rail kits
The following tables show rail kit information, which differs for VSP G200,
G400, G600, G800; VSP F400, F600, F800; and VSP G1000.
Table 4 Rail kits required for VSP G200, G400, G600, G800 and VSP F400,
F600, F800
Rail kit
Hitachi Universal V2 Rack
Third-party rack
Controller
UNI1
UNI1
Drive trays - DBS/DBL/DBF
CGR2
UNI1
Dense tray - DB60
Rail kits are included with dense tray.
SVP Server
Rail kits are included with SVP Server.
Notes:
1. UNI: Universal rail kit A34V-600-850-UNI.
2. CGR: Corner guide rail kit A3BF-HK-GL-740-1.
Table 5 Rail kits required for VSP G1000
Rail kit
Hitachi Universal V2 Rack
Third-party rack
Controller
CBX1
CBX1
Drive trays--SBX/UBX/FBX
CGR2
UNI
Notes:
1. CBX: VSP G1000 controller rail kit A34V-700-800-CBX.
2. CGR: Corner guide rail kit A3BF-HK-GL-740-1.
Rack accessories
The following table provides rack accessory information for VSP G200, G400,
G600, G800; VSP F400, F600, F800; and VSP G1000 storage systems.
18
Universal V2 Rack
Hitachi Universal V2 Rack Reference Guide for Hitachi Virtual Storage Platform G Series and F Series
Table 6 Rack accessories for Universal V2 Rack
Storage system
Front door
Rear door
Side panels
VSP G200, G400,
G600, G800 and VSP
F400, F600, F800
Optional, must be
ordered separately
(A3BF-DR).
Included with
rack.
Not included with rack, must
be ordered separately. A
quantity of two must be
ordered per rack (A3BF-ZPAN-1200).
VSP G1000
Optional, must be
ordered separately
(A3BF-DR-R800).
Included with
rack.
Not included with rack, must
be ordered separately (left
door - A3BF-Z-PAN-BR-L,
right door - A3BF-Z-PAN-BRR).
Dense intermix drive tray considerations
A maximum of nine dense intermix drive trays can be installed in the rack.
However, up to eight dense intermix drive trays can be installed when a
controller is installed in the rack.
In a Hitachi Universal V2 rack, intermix drive trays cannot be mounted
above:
• Rack shelves U36 through U39 due to drive-servicing restrictions imposed
by the rack door frame.
• Rack shelf U39; otherwise, the top crossbeam of the rack frame blocks the
back row of HDDs/SSDs.
Third-party racks
Third-party racks can be used for VSP G200, G400, G600, G800; VSP F400,
F600, F800; and VSP G1000 storage systems. However, each platform has
different requirements.
Third-party racks for VSP G200, G400, G600, G800 and VSP F400,
F600, F800
VSP G200, G400, G600, G800 and VSP F400, F600, F800 storage systems
support third-party racks that meet Hitachi Data Systems specifications.
• VSP G200, G400, G600, G800 and VSP F400, F600, F800 storage systems
support any 4-post, EIA310-D compliant rack, which must have adequate
airflow and weight capacity.
• PDUs must be mounted with no serviceability issues. The PDU receptacles
must face rearward (not toward each other). The area behind the storage
system and between the vertical 19-inch mounting posts must be free of
PDUs and cable loops.
Universal V2 Rack
Hitachi Universal V2 Rack Reference Guide for Hitachi Virtual Storage Platform G Series and F Series
19
Third-party racks for VSP G1000
Installation of VSP G1000 into a third party rack is by exception only and is
only allowed with prior approval. Contact your Hitachi Data Systems account
team or CS&S representative for more information.
20
Universal V2 Rack
Hitachi Universal V2 Rack Reference Guide for Hitachi Virtual Storage Platform G Series and F Series
Index
B
D
E
F
O
P
R
S
balancing allowable current load 15
T
third-party racks 19
VSP G1000 20
three phase PDUs 16
Dense intermix drive tray considerations 19
emergency guidelines 8
front door 18
front view 12
overview 11, 12
PDU specifications 16
PDUs
for Americas 15
for APAC / EMEA 15
plug types 17
rack accessories 18
rail kits 18
rear door 18
rear view 12
safety and emergency guidelines 8
side panels 18
single phase PDUs 16
specifications 12
Index
Hitachi Universal V2 Rack Reference Guide for Hitachi Virtual Storage Platform G Series and F Series
21
22
Index
Hitachi Universal V2 Rack Reference Guide for Hitachi Virtual Storage Platform G Series and F Series
Hitachi Universal V2 Rack Reference Guide for Hitachi Virtual Storage Platform G Series and F Series
Hitachi Data Systems
Corporate Headquarters
2845 Lafayette Street
Santa Clara, California 95050-2639
U.S.A.
www.hds.com
Regional Contact Information
Americas
+1 408 970 1000
info@hds.com
Europe, Middle East, and Africa
+44 (0) 1753 618000
info.emea@hds.com
Asia Pacific
+852 3189 7900
hds.marketing.apac@hds.com
MK-94HM8035-04
May 2016
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertising