Homeowner Guide

Homeowner Guide
Bath with Airjets
HOMEOWNERS GUIDE
P50045-G5, P50047-G5,
P50049-G5, P50052-G5
1096755-5-D
1 of 16 Kallista
©2014
Questions? Problems? For additional assistance, please contact KALLISTA’s Customer
Service Department at 1-888-4-KALLISTA (1-888-452-5547) or FAX 1-888-272-3094.
Bath with Airjets
HOMEOWNERS GUIDE
IMPORTANT SAFETY INSTRUCTIONS
READ AND FOLLOW ALL INSTRUCTIONS
SAVE THESE INSTRUCTIONS
INSTRUCTIONS PERTAINING TO A RISK OF FIRE, ELECTRICAL SHOCK, OR INJURY TO PERSONS
WARNING: When using electrical products, basic precautions should always be followed,
including the following:
DANGER: Risk of accidental injury or drowning. Do not permit children to use this unit unless they are
closely supervised at all times.
WARNING: Risk of personal injury. To avoid injury, exercise care when entering or exiting the bath.
WARNING: Risk of electric shock. Do not permit electric appliances (such as a hair dryer, lamp,
telephone, radio, or television) within 5’ (1.5 m) of this bath.
WARNING: The use of alcohol, drugs, or medication can greatly increase the risk of fatal
hyperthermia. Prolonged immersion in hot water may induce hyperthermia. Hyperthermia occurs when
the internal temperature of the body reaches a level several degrees above the normal body temperature
of 98.6°F (37°C). The symptoms of hyperthermia include an increase in the internal temperature of the
body, dizziness, lethargy, drowsiness, and fainting. The effects of hyperthermia include: (a) failure to
perceive heat, (b) failure to recognize the need to exit the bath, (c) unawareness of impending hazard, (d)
fetal damage in pregnant women, (e) physical inability to exit the bath, and (f) unconsciousness resulting
in the danger of drowning.
WARNING: Risk of fetal injury. Pregnant or possibly pregnant women should consult a physician before
using the bath.
WARNING: Risk of hyperthermia or drowning. Do not use the bath immediately following strenuous
exercise.
WARNING: Risk of hyperthermia or drowning. Water temperature in excess of 100°F (38°C) may
cause injury. Test and adjust the water temperature before use.
WARNING: Risk of personal injury. Never drop or insert any object into any opening.
An equipment grounding terminal is provided in the field wiring compartment. To reduce the risk of electric
shock, this terminal must be connected to the grounding means provided in the electric supply panel with a
conductor equivalent in size to the circuit conductors supplying this bath.
A pressure wire connector is provided on the exterior of the blower motor or control within this unit to permit
connection of a bonding conductor between this unit and all other exposed metal in the vicinity, as needed to
comply with local requirements.
Use this bath only for its intended purpose as described in this guide. Do not use attachments not
recommended by the manufacturer.
1096755-5-D
2 of 16
Questions? Problems? For additional assistance, please contact KALLISTA’s Customer
Service Department at 1-888-4-KALLISTA (1-888-452-5547) or FAX 1-888-272-3094.
Bath with Airjets
HOMEOWNERS GUIDE
IMPORTANT SAFETY INSTRUCTIONS (CONT’D)
The bath must be connected only to a supply circuit that is protected by a Ground-Fault Circuit-Interrupter
(GFCI)*. Such a GFCI should be provided by the installer and should be tested on a routine basis. To test
the GFCI, press the test button. The GFCI should interrupt power. Press the reset button. Power should be
restored. If the GFCI fails to operate in this manner, the GFCI is defective. If the GFCI interrupts power to the
bath without the test button being pressed, a ground current is flowing, indicating the possibility of an electric
shock. Do not use this bath. Disconnect the bath and have the problem corrected by a qualified service
representative before using.
Your new KALLISTA bath has been listed by Underwriter’s Laboratories, ensuring safety for you and your
family. This bath also conforms to rigid ANSI and IAPMO standards set within the plumbing industry.
*Outside North America, this device may be known as a Residual Current Device (RCD).
TABLE OF CONTENTS
Important Safety Instructions ............................................................................................................................. 2
Table of Contents ............................................................................................................................................... 3
Thank You For Choosing Kallista ...................................................................................................................... 3
Your Kallista Bath with Airjets ............................................................................................................................ 4
How to Use This Manual ................................................................................................................................... 4
User Keypad And Bath with Airjets Modes/Features ......................................................................................... 5
Operating Your Bath with Airjets ........................................................................................................................ 6
Care and Cleaning Instructions ......................................................................................................................... 7
Five-Year Limited Warranty ............................................................................................................................... 8
Troubleshooting Procedures ............................................................................................................................. 9
Service Parts ................................................................................................................................................... 15
THANK YOU FOR CHOOSING KALLISTA
We appreciate your commitment to KALLISTA quality products. Please take a moment to review this manual
before you install your KALLISTA product. If you encounter any installation or performance problems, please do
not hesitate to contact us at the phone number listed at the bottom of the page.
1096755-5-D
3 of 16
Questions? Problems? For additional assistance, please contact KALLISTA’s Customer
Service Department at 1-888-4-KALLISTA (1-888-452-5547) or FAX 1-888-272-3094.
Bath with Airjets
HOMEOWNERS GUIDE
YOUR KALLISTA BATH WITH AIRJETS
Bath
Airjet
Level Sensor
User Keypad
Blower Motor
Control
Your new bath with airjets is designed to stimulate, invigorate, and energize your body. You will use the
following components:
 Bath - Allows the bather to relax in comfort while enjoying the air massage.
 User Keypad - Located within easy reach, the keypad allows you to turn the bath on and off. It also allows
you to access the airjet modes and adjust the airflow.
 Airjets - Holes through which the air flows.
 Level Sensor - Determines when the bath has been drained and starts the timing for the automatic purge
cycle.
 Blower Motor - Provides quiet, variable speed power to force air through the airjets into the water and
create the soothing bubbling action.
HOW TO USE THIS MANUAL
 This manual is designed to help you troubleshoot any problems that may develop with the operation of the
bath with airjets.
 If a problem occurs, refer to the ″Troubleshooting″ section to determine a probable cause.
 Check the ″Service Parts″ section to determine the part numbers for any replacement parts necessary.
 Use the information on the bottom of the page to contact Kallista to order parts, or for help if you cannot
correct the problem.
1096755-5-D
4 of 16
Questions? Problems? For additional assistance, please contact KALLISTA’s Customer
Service Department at 1-888-4-KALLISTA (1-888-452-5547) or FAX 1-888-272-3094.
Bath with Airjets
HOMEOWNERS GUIDE
USER KEYPAD AND BATH WITH AIRJETS MODES/FEATURES
Zone 2
Zone 1
Zone 3
Air Flow Mode
Surge Mode
Increase Flow or Surge
Activates Mode Selected
Decrease Flow or Surge
Power On/Off
Indicator Bar
Rotate outer ring to
access desired mode.
Purge Mode
Rotating Ring Key Pad
 Power On/Off - Turns the blower motor on and off. Symbols illuminated in blue indicate available modes/
features. Modes which are operating will display in green.
 Activate Button - Press “OK” to activate the desired mode. The active mode will flash (green).
 Up Arrow - Increases the air flow when the air flow mode is active. Increases the pulse speed when the
surge mode is active.
 Down Arrow - Decreases the air flow when the air flow mode is active. Decreases the pulse speed when
the surge mode is active.
 Outer Ring - Rotate the outer ring to the desired mode. The selected mode will flash (blue).
 Indicator Bar - Shows the air flow volume when operating in the air flow mode. Shows the surge speed
when operating in the surge mode.
 Purge Mode - Select to initiate the purge mode manually. The purge cycle will not start if there is water in
the bath. The purge mode blows any residual water out of the air channels. The blower motor starts and
runs at a low speed for about two minutes. An automatic purge cycle occurs when the bath is drained and
the water level falls below the level sensors.
 Air Flow Mode - In this mode, air flow is directed through any combination of the airjets in the selected
zones. Air flow can be adjusted with the arrow buttons. When the surge mode is selected, the air flow mode
stops. When the air flow mode is selected while operating in the surge mode, the surge mode stops.
 Zone 1 - This mode is used to select or deselect the air flow through Zone 1.
 Zone 2 - This mode is used to select or deselect the air flow through Zone 2.
 Zone 3 - This mode is used to select or deselect the air flow through Zone 3.
 Surge Mode - When active, the air flow ramps up from minimum to maximum and then down again to
minimum. The surge speed is adjustable between 10 seconds to 60 seconds by using the up or down
buttons. The up and down arrow buttons can be used to adjust the surge speed. Zones can be selected or
deselected when in the surge mode.
1096755-5-D
5 of 16
Questions? Problems? For additional assistance, please contact KALLISTA’s Customer
Service Department at 1-888-4-KALLISTA (1-888-452-5547) or FAX 1-888-272-3094.
Bath with Airjets
HOMEOWNERS GUIDE
USER KEYPAD AND BATH WITH AIRJETS MODES/FEATURES (CONT’D.)
 User Keypad “Sleep” Modes - To enhance your bathing experience, the keypad is programmed to
darken after approximately 15 seconds of inactivity. Only the last feature selected will remain illuminated.
To resume normal operation, press any key or turn the outer ring. Approximately 60 seconds after all
equipment is turned off, the keypad will darken completely to conserve power. Press the power button or
turn the outer ring to reactivate the keypad.
OPERATING YOUR BATH WITH AIRJETS
Zone 2
Zone 1
Zone 3
Air Flow Mode
Surge Mode
Increase Flow or Surge
Activates Mode Selected
Decrease Flow or Surge
Power On/Off
Indicator Bar
Rotate outer ring to
access desired mode.
Purge Mode
Rotating Ring Key Pad
Starting the Unit
If the unit does not function properly, please refer to the “Troubleshooting” section.








Close the drain.
Fill the bath to a level at least 2” (51 mm) above the top of the airjets.
Use your hand to test the water temperature for comfort and safety.
Carefully enter the bath basin.
Press the On/Off button on the user keypad.
Observe that the air system starts and air begins to flow to all zones.
If desired, adjust the air flow rate using the up button or the down button.
After about 15 seconds, observe that only the last feature selected remains illuminated on the user keypad.
Selecting Air Flow Modes





1096755-5-D
6 of 16
Rotate the outer ring to select a desired mode.
Observe that the selected icon is flashing blue.
Press the ″OK″ button to activate the mode.
Observe that the active mode flashes green and the mode is implemented.
Observe that, after about 15 seconds, the icon stops flashing.
Questions? Problems? For additional assistance, please contact KALLISTA’s Customer
Service Department at 1-888-4-KALLISTA (1-888-452-5547) or FAX 1-888-272-3094.
Bath with Airjets
HOMEOWNERS GUIDE
OPERATING YOUR BATH WITH AIRJETS (CONT’D.)
 To turn off a mode, rotate the outer ring until the icon flashes green and then press the “OK” button again.
 The icon will then turn blue indicating the mode is off.
Stopping the Bath
When ready, press the power button a second time to stop the air system.
Carefully exit the bath.
Open the drain to empty the bath.
Observe that, when the bath drains below the level sensors, the automatic 2-minute purge cycle occurs.
The air system operates at a low speed to blow any residual water out of the air channels.
 Observe that, about 60 seconds after shutdown, all user keypad lights extinguish.




Initiating a Manual Purge Cycle
After stopping the air system and draining the bath, rotate the ring on the user keypad to the purge icon.
Observe that the purge cycle icon is flashing blue.
Press the ″OK″ button once.
The purge icon flashes green and the mode is implemented. The air system operates at a low speed to
blow any residual water out of the air channels.
 After about 2 minutes, the air system stops automatically.




CARE AND CLEANING INSTRUCTIONS
 Do not use powdered cleaners unless the cleaner is fully dissolved in water. Solid substances could block
the airjets.
 Do not use full strength bleach or ammonia cleaning solutions. Chemically active cleaning solutions can
damage the bath surface.
 Do not use abrasive cleansers or solvents on acrylic surfaces. Abrasive cleaners and solvents can damage
the bath surface.
 Wipe out your acrylic bath with a soft cloth after each use.
 Avoid detergents, disinfectants, or cleaning products in aerosol cans.
NOTE: To restore dull or scratched units: Apply white automotive polishing compound with a clean rag. Rub
scratches and dull areas vigorously. Wipe off residue. Follow with a coat of white automotive paste wax. Do not
wax areas where you walk or stand.
Cleaning Your User Keypad and Remote Control
 Use a soft cloth to wipe the keypad and remote control after each use. If the surface becomes dirty, use a
non-abrasive soap and warm water to clean.
1096755-5-D
7 of 16
Questions? Problems? For additional assistance, please contact KALLISTA’s Customer
Service Department at 1-888-4-KALLISTA (1-888-452-5547) or FAX 1-888-272-3094.
Bath with Airjets
HOMEOWNERS GUIDE
CARE AND CLEANING INSTRUCTIONS (CONT’D.)
Maintaining the Airjets
 If cleaning the airjets is required due to hard water deposits, use a small between-the-teeth dental brush
and white vinegar. Dip the brush in the vinegar, brush the hole, rinse the brush in clean water, and then use
the wet rinsed brush to rinse the hole.
 Fill the bath with water to the top row of airjets. Drain the bath and press the purge button.
Flushing your Airbath System







Flush your whirlpool system twice a month or more, depending upon usage.
Fill bath with water one inch above the top of all airjets.
While bath is filling, carefully add one cup of bleach to the water.
Let sit for 10-15 minutes.
Drain the water, run the purge cycle and rinse any debris from the bath.
Clean bath surfaces as needed with recommended cleaners.
Dry the bath with a clean, soft towel.
FIVE-YEAR LIMITED WARRANTY
All Kallista products carry Kallista’s five-year warranty unless otherwise noted.*
Kallista’s products are warranted to be free of defects in material and workmanship for five years from the date
of installation.
Kallista will, at its election, repair, replace, or make appropriate adjustment where Kallista inspection discloses
any such defects occurring in normal usage within five (5) years after installation. Kallista is not responsible
for removal or installation costs. Damages due to improper handling, installation or maintenance are not
considered manufacturing defects and are not covered by this warranty. This warranty is valid for the original
consumer purchaser only. Use of in-tank toilet cleaners will void the warranty.
To obtain warranty service, contact you Kallista Authorized Showroom.
IMPLIED WARRANTIES INCLUDING THAT OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR
PURPOSE ARE EXPRESSLY LIMITED IN DURATION TO THE DURATION OF THIS WARRANTY. KALLISTA
AND/OR SELLER DISCLAIMS ANY LIABILITY FOR SPECIAL, INCIDENTAL, OR CONSEQUENTIAL
DAMAGES.
Some states/provinces do not allow limitations on how long an implied warranty lasts, or the exclusion or
limitation of special, incidental or consequential damages, so these limitations and exclusions may not apply to
you. This warranty gives you specific legal rights. You may also have other rights which vary from state/province
to state/province.
This is Kallista’s exclusive written warranty.
* Kallista’s Hampstead and Stafford vitreous products, stainless steel accessories, and wooden accessories
carry a one-year Limited Warranty.
1096755-5-D
8 of 16
Questions? Problems? For additional assistance, please contact KALLISTA’s Customer
Service Department at 1-888-4-KALLISTA (1-888-452-5547) or FAX 1-888-272-3094.
Bath with Airjets
HOMEOWNERS GUIDE
TROUBLESHOOTING PROCEDURES
Zone 2
Zone 1
Zone 3
Air Flow Mode
Surge Mode
Increase Flow or Surge
Activates Mode Selected
Decrease Flow or Surge
Power On/Off
Indicator Bar
Rotate outer ring to
access desired mode.
Purge Mode
Rotating Ring Key Pad
This troubleshooting guide is for general aid only. A Kallista Authorized Service Representative or qualified
electrician should correct all electrical problems. For warranty service, call 1-888-452-5547.
Troubleshooting the Bath with Airjets System
Symptoms
Probable Causes
1. User keypad does not illuminate A. No power to control.
when power button is pressed or
the outer ring is rotated.
B. Ground-Fault Circuit-Interrupter
(GFCI) or Residual Current
Device (RCD) tripped.
C. Wiring harness from user
keypad to control is loose,
disconnected or damaged.
D. User keypad does not work.
E. Control does not work.
1096755-5-D
9 of 16
Recommended Action
A. Check wiring and connect
power.
B. Reset GFCI or RCD. If it trips
again, refer to “Ground-Fault
Circuit-Interrupter (GFCI) or
Residual Current Device (RCD)
trips when bath with airjets is
turned on”.
C. Check wiring for proper
connections. Replace the wiring
harness if necessary. Refer
to your installer or wholesale
dealer.
D. Replace the user keypad. Refer
to your installer or wholesale
dealer.
E. Replace the control. Refer
to your installer or wholesale
dealer.
Questions? Problems? For additional assistance, please contact KALLISTA’s Customer
Service Department at 1-888-4-KALLISTA (1-888-452-5547) or FAX 1-888-272-3094.
Bath with Airjets
HOMEOWNERS GUIDE
Symptoms
2. Ground-Fault Circuit-Interrupter
(GFCI) or Residual Current
Device (RCD) trips when bath
with airjets is turned on.
Probable Causes
A. Electrical harness is wet or
damaged.
B. Electrical wiring to the bath
junction box is wet or damaged.
C. Electrical wiring to the bath
power cord is wet or damaged.
D. Blower motor is shorted
internally.
E. Control is shorted internally.
3. User keypad is illuminated, but
does not respond to buttons or
outer ring.
A. Control program is locked.
B. P5 plug assembly harness from
user keypad to control is loose,
disconnected, or damaged.
C. User keypad does not work.
D. Control does not work.
1096755-5-D
10 of 16
Recommended Action
A. Check for wet connections.
Dry the connections and repair
the leak. Check for insulation
or connector damage. Replace
the harness if damaged. Refer
to your installer or wholesale
dealer.
B. Have a qualified electrician
diagnose and correct the
problem in accordance with
applicable building and electrical
codes.
C. Have a qualified electrician
diagnose and correct the
problem in accordance with
applicable building and electrical
codes.
D. Replace the blower motor. Refer
to your installer or wholesale
dealer.
E. Replace the control. Refer
to your installer or wholesale
dealer.
A. Reset GFCI or RCD.
B. Check wiring for proper
connections. Replace the wiring
harness if necessary. Refer
to your installer or wholesale
dealer.
C. Replace the user keypad. Refer
to your installer or wholesale
dealer.
D. Replace the control. Refer
to your installer or wholesale
dealer.
Questions? Problems? For additional assistance, please contact KALLISTA’s Customer
Service Department at 1-888-4-KALLISTA (1-888-452-5547) or FAX 1-888-272-3094.
Bath with Airjets
HOMEOWNERS GUIDE
Symptoms
4. Blower motor will not start.
5. Blower motor stops running
and will not immediately restart.
Keypad is illuminated.
6. Blower motor starts, some but
not all airjets are bubbling.
1096755-5-D
11 of 16
Probable Causes
Recommended Action
A. Power cord from blower motor
A. Check wiring for proper
to control is loose, disconnected,
connections.
or damaged.
B. Blower motor does not work.
B. Replace the blower motor. Refer
to your installer or wholesale
dealer.
C. Control does not work.
C. Replace the control. Refer
to your installer or wholesale
dealer.
A. Blower motor overheated and
A. Check for blockage at motor
protection device activated.
vents. Remove blockage and
allow motor to cool. Refer to
dealer or wholesale distributor.
Otherwise, refer to “User keypad
is illuminated, but does not
respond to buttons or outer ring.
Blower motor will not start.”
A. Blower motor speed is too low. A. Increase speed setpoint to
blower motor.
B. Blower motor inlet is blocked.
B. Clean blower motor inlet.
C. Blower motor does not work.
C. Replace the blower motor. Refer
to your installer or wholesale
dealer.
D. Blower motor discharge is
D. Check blockage.
blocked.
E. Check valve does not work.
E. Replace the check valve. Refer
to your installer or wholesale
dealer.
F. Air jets are clogged.
F. Use a small between-the-teeth
dental brush and white vinegar.
Dip the brush in the vinegar,
brush the hole, rinse the brush
in clean water, and then use the
wet rinsed brush to rinse the
hole.
Questions? Problems? For additional assistance, please contact KALLISTA’s Customer
Service Department at 1-888-4-KALLISTA (1-888-452-5547) or FAX 1-888-272-3094.
Bath with Airjets
HOMEOWNERS GUIDE
Symptoms
7. Blower motor runs but no air
bubbles are formed.
Probable Causes
A. Blower motor inlet is blocked.
B. Air jets are clogged.
C. Check valve does not work.
D. Blower motor does not work.
E. Control does not work.
8. Blower motor operates, air
bubbles are formed, zone
controls work, but variable
speed feature does not work.
A. Blower motor inlet is blocked.
B. Loose, disconnected, or
damaged wiring harness.
C. User keypad does not work.
D. Blower motor does not work.
E. Control does not work.
1096755-5-D
12 of 16
Recommended Action
A. Clean blower motor inlet.
B. Use a small between-the-teeth
dental brush and white vinegar.
Dip the brush in the vinegar,
brush the hole, rinse the brush
in clean water, and then use the
wet rinsed brush to rinse the
hole.
C. Replace the check valve. Refer
to your installer or wholesale
dealer.
D. Replace the blower motor. Refer
to your installer or wholesale
dealer.
E. Replace the control. Refer
to your installer or wholesale
dealer.
A. Clean blower motor inlet.
B. Check wiring for proper
connections. Replace the wiring
harness if necessary. Refer
to your installer or wholesale
dealer.
C. Replace the user keypad. Refer
to your installer or wholesale
dealer.
D. Replace the blower motor. Refer
to your installer or wholesale
dealer.
E. Replace the control. Refer
to your installer or wholesale
dealer.
Questions? Problems? For additional assistance, please contact KALLISTA’s Customer
Service Department at 1-888-4-KALLISTA (1-888-452-5547) or FAX 1-888-272-3094.
Bath with Airjets
HOMEOWNERS GUIDE
Symptoms
9. Blower motor won’t turn off
when the power button on user
keypad is pressed.
Probable Causes
A. User keypad does not work.
B. Loose, disconnected, or
damaged wiring harness.
C. Control does not work.
10. A zone does not produce
air bubbles but another zone
operates normally.
A. Zone is not selected.
B. Butterfly valve does not work.
C. Loose, disconnected, or
damaged wiring harness.
D. User keypad does not work.
E. Control does not work.
11. Surge mode does not work.
A. User keypad does not work.
B. Control does not work.
1096755-5-D
13 of 16
Recommended Action
A. Replace the user keypad. Refer
to your installer or wholesale
dealer.
B. Check wiring for proper
connections. Replace the wiring
harness if necessary. Refer
to your installer or wholesale
dealer.
C. Replace the control. Refer
to your installer or wholesale
dealer.
A. Select the zone per the
instructions in the “Confirm
Proper Operation” section.
B. Replace the butterfly valve.
Refer to your installer or
wholesale dealer.
C. Check wiring for proper
connections. Replace the wiring
harness if necessary. Refer
to your installer or wholesale
dealer.
D. Replace the user keypad. Refer
to your installer or wholesale
dealer.
E. Replace the control. Refer
to your installer or wholesale
dealer.
A. Replace the user keypad. Refer
to your installer or wholesale
dealer.
B. Replace the control. Refer
to your installer or wholesale
dealer.
Questions? Problems? For additional assistance, please contact KALLISTA’s Customer
Service Department at 1-888-4-KALLISTA (1-888-452-5547) or FAX 1-888-272-3094.
Bath with Airjets
HOMEOWNERS GUIDE
Symptoms
12. Water spillage or damage
observed under the bath.
Probable Causes
A. Drain or overflow leaking.
B. Wall, deck, and/or shower door
is improperly sealed.
C. Cracked acrylic air channels.
1096755-5-D
14 of 16
Recommended Action
A. Repair or replace the drain
assembly per the manufacturer’s
instructions.
B. Apply silicone sealant at the
seams between the bath and the
wall, deck, or door.
C. Refer to the manufacturer.
Questions? Problems? For additional assistance, please contact KALLISTA’s Customer
Service Department at 1-888-4-KALLISTA (1-888-452-5547) or FAX 1-888-272-3094.
Bath with Airjets
HOMEOWNERS GUIDE
SERVICE PARTS
Note: All tubing 1" unless otherwise noted.
1096498
Butterfly
1-1/4" Tubing
1-1/2" Tubing
1-1/2" Tubing
1036218
Check Valve
58946
Screw
1035938
Washer
95045
Screw
1036216
Blower Kit
1-1/2" Tubing
95045
Screw
95045
Screw
1038690
Vent Assembly
1096755-5-D
15 of 16
Questions? Problems? For additional assistance, please contact KALLISTA’s Customer
Service Department at 1-888-4-KALLISTA (1-888-452-5547) or FAX 1-888-272-3094.
Bath with Airjets
HOMEOWNERS GUIDE
61776
Lock Washer
1033678
Screw
73519
Water Level Probe
63270
Washer
93892-A
Electrical Box
67065
Ground Lug
93841
Screw
93893
Cover
93003
Strain Relief
93836 (1/2")
93838 (1")
93839 (1-1/4")
94853 (1-1/2")
Tube (w/Couplings)
63270
Washer
60129
Nut
60129
Nut
1021777
Wire Harness
1035939
Screw
Butterfly Valve
1032583
Board
1036872
Control Kit
96956
Butterfly
50506
Screw
1016466
Motor
1032645
Control
63149
Screw
1019447-B
Isolation Mount
1032507
Plug/Wire Assembly
1032509
Plug/Wire Assembly
61845-K
Grounding Wire
1020677
Gasket
1023381
Wrench
1039250-R-*
Key Pad
65157
Nut
**Finish/color code must be specified when ordering.
1096755-5-D
16 of 16
Questions? Problems? For additional assistance, please contact KALLISTA’s Customer
Service Department at 1-888-4-KALLISTA (1-888-452-5547) or FAX 1-888-272-3094.
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertising