GAT SLA 300

SlimLine RFID Antenna for Entry Control

Application

The RFID antenna GAT SLA 300 is used for identification of persons within entry control systems. The identification is made using RFID (Radio

Frequency Identification) data carriers. The evaluation and authorisation is performed by the connected entry control terminal.

The slime shape of the GANTNER SlimLine design allows for installation e.g. on tubular frame doors or slime structure elements.

Functional description

Persons identify themselves with their own data carriers at the GAT SLA 300.

The information is read and transferred via the HF interface to a control unit in a secured area, which then makes the authorisation check and controls the unlocking device accordingly. An entry control terminal from

GANTNER (GAT Access 6200, GAT Terminal 2500, GAT ST 210 or GAT

ST 260) is used as control unit.

A 2 coloured background lighting of the reader point serves as signalling to users. The 4-segment LED-display at the top of the housing serves as user guidance as well as for display of various status information. A beeper is also integrated in the GAT SLA 300 for acoustic signal feedback.

Highlights

• Ergonomic design in GANTNER look&feel

• Slim shape excellent for mounting on door frames

• Reading and writing of 13.56 MHz RFID data carriers (depending on type

of connected terminal LEGIC ® Prime, LEGIC ® Advant, MIFARE ® Standard,

HID I-Class, ISO 14443A and ISO 15693

• Clear signalling with LED bar and illuminated, round scan field

• Easy electrical installation and mounting

• Plug&Play installation

• Smooth and rounded design for ease of access e.g. at turnstiles to prevent

baggage etc. getting caught or damaged

• Mounting on metal surfaces is possible

• Suitable for outdoor use

Oderinformation

Description

GAT SLA 300

SlimLine RFID antenna, 13.56 MHz, in housing for surface mounting

Accessories

Description

GAT Access 6200 B

Entry control terminal with LEGIC ® reader

GAT Access 6200 F

Entry control terminal with MIFARE ® reader

GAT Access 6200 ISO

Entry control terminal with ISO 15693 reader

GAT Terminal 2500 AB

Access control terminal with LEGIC ® reader

GAT Terminal 2500 AF

Access control terminal with MIFARE ® reader

GAT ST 210

Offline access control terminal with LEGIC ® reader

GAT ST 260

Online access control terminal with LEGIC ® reader

PartNo.

909586

PartNo.

826786

826887

826988

427581

509481

434377

499590 www.gantner.com

Valid as from April 26 th 2010 • Technical data subject to modifications without notic!

DB_GAT-SLA300_EN_11.indd • PartNo.: 989089 1

Technical data

Nominal voltage:

Frequency reader field:

Supported RFID technologies:

Reading distance:

Display elements/signalling

- Reader:

- Bar display:

- Akustischer Signalgeber:

12 - 24 VDC, from control unit

13.56 MHz

(depending on type of conn. terminal)

- LEGIC ® Prime/LEGIC ® Advant

- MIFARE ® Standard

- HID I-Class

- ISO 14443A

- ISO 15693

2 - 8 cm (depending on data carrier)

Background lighting,

2 different colours

4 LED-segments in 3 different colours

Beeper

Interface to control unit:

Housing material:

Dimensions:

- Data (HF coaxial)

- Signal line (power supply, LEDs,

beeper)

Plastic

44 x 139.9 x 22.2 mm

Permitted ambient temperature: -20 to +70°C

Permitted storage temperature: -20 to +70°C

Protection type: IP 54

Protection class:

Weight:

Environment class based on VDS 2110:

III

0.5 kg

III (conditions in outdoor areas)

Dimensions

1

3

2

3

4

44,0 mm

22,2 mm

1. LED status display

2. Illuminated round scan field

3. Fastening screws (2 x)

4. Potentiometer for antenna calibration

Typical application

Power supply

GAT Access 6200

GAT Terminal 2500

Network

GAT SLA 300

Door strike

2

Valid as from April 26 th 2010 • Technical data subject to modifications without notic!

DB_GAT-SLA300_EN_11.indd • PartNo.: 989089 www.gantner.com

Mounting and installation instructions

The device back part is mounted to a flat background (e.g. concrete wall).

Mounting is also permitted on a metallic background, in which case the internal antenna must be calibrated to adjust the reading field.

Recommended mounting height: bottom edge of device 1.3 m.

1

3

8

7

9

5 5

6

3

2

4

Mounting

First connect the cables according to the electrical connection scheme on page 4. Connection must be made in power-less state. The cables are flush-mounted (6). Please ensure that the cable outlet in the wall isn‘t visible after mounting the GAT SLA 300. After connecting the cables press the connection terminal cover (8) tightly onto the terminal (for protection against dirt and humidity).

The device back part is fixed to the background with two screws (3). Use proper screws and dowels according to the type of background, in order to guarantee that the GAT SLA 300 is attached securely.

If the GAT SLA 300 is mounted in outside area, the sealing cap (9) must be cut-off from the terminal cover and plugged into the opening of the potentiometer (4) for protection against dirt and humidity. If necessary first calibrate the internal antenna with the potentiometer.

22,2 mm 44,0 mm

1. LED status display

2. Illuminated round scan field

3. Fastening screws (2 x)

4. Potentiometer for antenna calibration

5. Device back part

6. Flush-mounted cable

7. Connection terminals

8. Connection terminal cover

9. Sealing cap

Calibration of internal antenna

For correct adjustment of the RFID reading field the internal antenna can be calibrated using the calibration potentiometer (4). Therefore first connect the GAT SLA 300 to the terminal (see page 4). Use a nonmetallic screw driver to turn the potentiometer and simultaneously use a GAT Power Meter 1000 (PartNo.: 370010) or a data carrier to test the strength of the RFID reading field. Use one of the data carriers that will also be used in the entry control system later.

Attachment of the device upper part

After mounting and electrical connection the device upper part is clipped onto the device back part as shown by the following figures.

1. 2.

Removing the device upper part

If the GAT SLA 300 must be dismounted, e.g. in case of maintenance work, the device upper part must be removed. Therefore use a flat tool

(e.g. a screw driver) to push into the slot on the bottom of the housing in order to loosen the upper part and to carefully swing it forward.

1. 2.

www.gantner.com

Valid as from April 26 th 2010 • Technical data subject to modifications without notic!

DB_GAT-SLA300_EN_11.indd • PartNo.: 989089 3

Electrical connections

Connection to GAT Access 6200

GAT SLA 300

GAT Access 6200

2

1

Connection to GAT Terminal 2500

GAT SLA 300

GAT Terminal 2500

Ethernet

Host

Peripherie

2

1 ext. Reader

SD-Card

Power supply

DC power supply (see technical data) from the connected control unit.

Recommended cable / cable length

Signal cable (1): shielded data line (recommendation e.g. CAT5)

Antenna cable (2): 50 Ω coax cable (recommendation RG 58 or RG 316)

Cable length depends on the control unit, max. 40 m.

Connectable to the following control units

GAT Access 6200 B/F/ISO, GAT Terminal 2500 AB/AF, GAT ST 210,

GAT ST 260

4

Valid as from April 26 th 2010 • Technical data subject to modifications without notic!

DB_GAT-SLA300_EN_11.indd • PartNo.: 989089

Safety instructions

- This device must be installed by qualified personnel only.

- The applicable safety and accident prevention regulations must be observed.

- Safety devices must not be removed.

- Please observe the technical data of the device specified on the data sheet.

- The device must be disconnected from the power supply prior to installation, assembly or dismantling.