radio remote control
TECHNICAL DATA
Harmony 5000
product range
Harmony 5000
RADIO REMOTE CONTROL
Controlling heating, light and appliances
CTG Art.no.: 910060
CTG
Remote control
Harmony 5000
Art.no.: 910060
Function / product description CTG
Signal Repeater
Glamox Harmony remote control provide fully
programmable, energy saving control for the Glamox
3001 range of radiators and thermostats, controlling
heater output based on room occupancy and
temperature requirements by radio signals.
Should extended range of
transmission be needed a
Repeater must be inserted
between the remote control
CTG and the receivers.
This will extend the radio
range to up to twice the
normal range for CTG alone.
•
•
•
•
•
•
•
•
•
•
Optimal temperature Comfort and energy saving
Easy to use - menu based visual programming
24 hour uninterruptible function after power cut
No installation required – wireless system
No interference with neighbor systems
When the system is installed it is ready to go
Suitable for residences, flats, offices , business premises etc.
16 heating zones, 8 zones for on-off control of appliances
Advanced technology and high quality components
Easy override of the program with ”hot-keys”
The Repeater has a
separate power supply from
a 6 V DC adapter.
Specifications
Standards
•
•
•
•
•
•
EN61000-6-1:2004
EN61000-6-3:2004
EN60730-1:2003
•
•
•
•
Based on single chip radio technology
Menu based progamming (like mobile telephone interface)
Transmitting at 433,92 Mhz ± 150 kHz
Output < 10 dBm
Conforms ETS 300-220
Radio range within normal buildings 25-35 meter
(repeater available)
EEPROM (memory) no program loss at power cut
24 hours operation on battery backup
48 hours backup for clock function
Real time clock – max. deviation 5 min/year
EN300220-1:2006
EN300220-2:2006
EN301489-1:2005
EN301489-3:2002
RF
Signal repeater
Art.no.: 910087
CRG
Thermostat, plug-in.
CRG2 (230V) Art.no.: 910066
CRG4 (400V) Art.no.: 910067
CRMG
Master thermostat,
plug-in (SLA 5/24)
CRMG2 (230V) Art.no.: 910068
CRMG4 (400V) Art.no.: 910069
SFG
Floor heat thermostat
SFG2 (230V) Art.no.: 910100
SFG4 (400V) Art.no.: 910101
SMG
Master thermostat
Wallmounted
SMG2 (230V) Art.no.: 910105
SMG4 (400V) Art.no.: 910106
SXG
Relay, fixed installation
SXG2 (230V) Art.no.: 910110
SXG4 (400V) Art.no.: 910111
COG-e
Relay, with lead and plug
Art.no.: 910074
Connection
CTG should be placed in
the charger unit during
normal operation.
Charger is connected to
the 230 Volt supply,
either with lead and plug
or directly to the
connector
block inside
the charger
unit.
Measures
CTG
CSW
Wall sensor
Art.no.: 910085
GSM
Complete
Art.no.: 910081
GSM
Basic
Art.no.: 910080
(Available upon request)
TECHNICAL DATA
Harmony 5000
RADIO REMOTE CONTROL
Controlling heating, light and appliances
CTG Art.no.: 910060
Harmony 5000 Zonal Heat Control
Harmony 5000 Dial-up cottage heating
Wiring diagram
GSM Complete
TECHNICAL DATA
Harmony 5000
Harmony 5000
product range
SIGNAL REPEATER
RF Art.no.: 910087
CTG
Remote control
Harmony 5000
Art.no.: 910060
Function / product description RF
Should extended range of transmission be needed a Repeater must be inserted between the
remote control CTG and the receivers. This will extend the radio range to up to twice the
normal range for CTG alone. The Repeater has a separate power supply from a 6 V DC
adapter.
Receive radio signals from the Harmony 5000 remote control and store the information.
As soon as the Remote control end transmission the Repeater transmit the same
commands to all receivers within its radio range. The LED will be on during receiving
signals from the remote control.
The repeater is linked up to the remote control the following way:
• CTG is set to LINK UP modus (any zone number will do)
• Press the button with hand symbol firmly more than 5 seconds
• A green light flashes when LINK UP is ok
RF
Signal repeater
Art.no.: 910087
CRG
Thermostat, plug-in.
CRG2 (230V) Art.no.: 910066
CRG4 (400V) Art.no.: 910067
CRMG
Master thermostat,
plug-in (SLA 5/24)
CRMG2 (230V) Art.no.: 910068
CRMG4 (400V) Art.no.: 910069
No more than one Repeater should be LINKED UP to each remote control.
Specifiactions
Standards
• Rated supply voltage: 6 V DC
• Rated power: Standby=0,1 Watt. Transmission = 0,35 Watt
• Radio transmission at 433,93 MHz
• Sensitivity -110 dBm at maximum antenna again
• Transmission power: 10 dBm at maximum antenna gain
• Bandwith / bit rate: 1200 bauds
• Modulation: ASK/OOK
EN61000-6-1:2004
EN61000-6-3:2004
EN61000-4-2:2001
EN60730-1:2003
EN300220-1:2006
EN300220-2:2006
EN301489-1:2005
EN301489-3:2002
SFG
Floor heat thermostat
SFG2 (230V) Art.no.: 910100
SFG4 (400V) Art.no.: 910101
SMG
Master thermostat
Wallmounted
SMG2 (230V) Art.no.: 910105
SMG4 (400V) Art.no.: 910106
SXG
Relay, fixed installation
SXG2 (230V) Art.no.: 910110
SXG4 (400V) Art.no.: 910111
COG-e
Relay, with lead and plug
Art.no.: 910074
Measures
RF Repeater
CSW
Wall sensor
Art.no.: 910085
Cartoon box measures:
200 x 70 x 140 mm
Weight (Inclusive Adapter):
0,425 kg
Height
Width
Depth
Weight
170 mm
50 mm
28 mm
0,105 kg
GSM
Complete
Art.no.: 910081
GSM
Basic
Art.no.: 910080
(Available upon request)
TECHNICAL DATA
Harmony 5000
Harmony 5000
product range
FLOOR HEAT THERMOSTAT
SFG2 (230 V) Art.no.: 910100
SFG4 (400 V) Art.no.: 910101
CTG
Remote control
Harmony 5000
Art.no.: 910060
Function / product description SFG
Signal Repeater
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
Should extended range of
transmission be needed a
Repeater must be inserted
between the remote control
CTG and the receivers.
This will extend the radio
range to up to twice the
normal range for CTG alone.
Receive signals from Harmony 5000 remote control
Temperature range 5 –35 ºC
Two regulation modus: hysteresis and proportional regulation
Proportional regulation, duty cycle 10 minutes
Hysteresis regulation ± 0,5ºC
Built in room temperature sensor, floor sensor attached
Manual selection of internal and external temperature sensor
Calibration within ± 5ºC
Local control only is possible
Central lock prevents local change of setpoint (childsafe)
Load symbol show when thermostat is activating the heat source
Antenna symbol show when the remote control is in control
Hand symbol show when the unit is under local control
Digital display of temperature setpoint
Zone number show when SFG main switch is operated
Choice of temperature sensor show in display.
Max. temperature limit for wooden underfloor heating
The Repeater has a
separate power supply from
a 6 V DC adapter.
Specifications
Standards
• Rated voltage: 230 Volt (SFG2) 400 Volt (SFG4)
• Rated current: 16 Amp.
• Mains switch 2-pole
• Safety protection class: IP20
• Insulation class: II
• Temperature sensor : NTC 10k Ω / 25ºC
• Load relay: 1-pole
• Radio transmission at 433,93 MHz
• Sensitivity -110 dBm
EN61000-6-1:2004
EN61000-6-3:2004
EN61000-4-2:2001
EN60730-1:2003
EN300220-1:2006
EN300220-2:2006
EN301489-1:2005
EN301489-3:2002
RF
Signal repeater
Art.no.: 910087
CRG
Thermostat, plug-in.
CRG2 (230V) Art.no.: 910066
CRG4 (400V) Art.no.: 910067
CRMG
Master thermostat,
plug-in (SLA 5/24)
CRMG2 (230V) Art.no.: 910068
CRMG4 (400V) Art.no.: 910069
SFG
Floor heat thermostat
SFG2 (230V) Art.no.: 910100
SFG4 (400V) Art.no.: 910101
SMG
Master thermostat
Wallmounted
SMG2 (230V) Art.no.: 910105
SMG4 (400V) Art.no.: 910106
SXG
Relay, fixed installation
SXG2 (230V) Art.no.: 910110
SXG4 (400V) Art.no.: 910111
COG-e
Relay, with lead and plug
Art.no.: 910074
Connection
Input:
2-pole connector block 2,5
Output:
2-pole connector block 2,5
Measures
SFG
CSW
Wall sensor
Art.no.: 910085
External sensor:
2-pole connector block 2,5
GSM
Complete
Art.no.: 910081
GSM
Basic
Art.no.: 910080
(Available upon request)
TECHNICAL DATA
Harmony 5000
FLOOR HEAT THERMOSTAT
SFG2 (230 V) Art.no.: 910100
SFG4 (400 V) Art.no.: 910101
Wiring diagram (direct output)
Wiring diagram (external relay for separate heating circuits)
TECHNICAL DATA
Harmony 5000
Harmony 5000
product range
MASTER THERMOSTAT
SMG2 (230 V) Art.no.: 910105
SMG4 (400 V) Art.no.: 910106
Function / product description SMG
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
Receive signals from Harmony 5000 remote control
Temperature range 5 –35 ºC
Proportional regulation, duty cycle 120 seconds
Built in room temperature sensor, floor sensor attached
Manual selection of internal and external temperature sensor
Calibration within ± 5ºC
Local control only is possible
Central lock prevents local change of setpoint (childsafe)
Load symbol show when thermostat is activating the heat source
Antenna symbol show when the remote control is in control
Hand symbol show when the unit is under local control
Digital display of temperature setpoint
Zone number show when SFG main switch is operated
Choice of temperature sensor show in display.
Max. limit for wooden underfloor heating
CTG
Remote control
Harmony 5000
Art.no.: 910060
Signal Repeater
Should extended range of
transmission be needed a
Repeater must be inserted
between the remote control
CTG and the receivers.
This will extend the radio
range to up to twice the
normal range for CTG alone.
The Repeater has a
separate power supply from
a 6 V DC adapter.
Specifications
Standards
•
•
•
•
EN61000-6-1:2004
EN61000-6-3:2004
EN61000-4-2:2001
EN60730-1:2003
•
•
•
•
•
•
•
Rated voltage: 230 Volt (SFG2) 400 Volt (SFG4)
Output: 6 V DC, max. 10 mA
Slavecontrol: Max. 10 slave module SLA 5-24
Single relay control: control one SSR directly
(SSR=solid state relay)
Multiple relay control: using a 6V to DC/230 V AC link
relay (see wiring diagram)
Mains switch 2-pole
Safety protection class: IP20
Insulation class: II
Temperature sensor : NTC 10k Ω / 25ºC
Radio transmission at 433,93 MHz
Sensitivity -110 dBm
EN300220-1:2006
EN300220-2:2006
EN301489-1:2005
EN301489-3:2002
RF
Signal repeater
Art.no.: 910087
CRG
Thermostat, plug-in.
CRG2 (230V) Art.no.: 910066
CRG4 (400V) Art.no.: 910067
CRMG
Master thermostat,
plug-in (SLA 5/24)
CRMG2 (230V) Art.no.: 910068
CRMG4 (400V) Art.no.: 910069
SFG
Floor heat thermostat
SFG2 (230V) Art.no.: 910100
SFG4 (400V) Art.no.: 910101
SMG
Master thermostat
Wallmounted
SMG2 (230V) Art.no.: 910105
SMG4 (400V) Art.no.: 910106
SXG
Relay, fixed installation
SXG2 (230V) Art.no.: 910110
SXG4 (400V) Art.no.: 910111
COG-e
Relay, with lead and plug
Art.no.: 910074
Connection
Input:
2-pole connector block 2,5
Output:
2-pole connector block 2,5
External sensor:
2-pole connector block 2,5
Measures
SMG
CSW
Wall sensor
Art.no.: 910085
GSM
Complete
Art.no.: 910081
GSM
Basic
Art.no.: 910080
(Available upon request)
TECHNICAL DATA
Harmony 5000
MASTER THERMOSTAT
SMG2 (230 V) Art.no.: 910105
SMG4 (400 V) Art.no.: 910106
Wiring diagram SMG (Solid State Relay)
Wiring diagram SMG (Heaters with SLA5/24 plug-in module)
TECHNICAL DATA
Harmony 5000
Harmony 5000
product range
RELAY FIXED INSTALLATION
SXG2 (230 V) Art.no.: 910110
SXG4 (400 V) Art.no.: 910111
CTG
Remote control
Harmony 5000
Art.no.: 910060
Function / product description SXG
Signal Repeater
Receive radio signal from the Harmony 5000 remote
control switching the relay on- or off. Makes light,
appliances, motors and fans work only at times preset
in the Harmony 5000 program.You can easily make
your own program that suits exactly to your needs.
Should extended range of
transmission be needed a
Repeater must be inserted
between the remote control
CTG and the receivers.
This will extend the radio
range to up to twice the
normal range for CTG alone.
•
•
•
•
•
Receive signals from Harmony 5000 remote control
Local control only is possible
Central lock prevents local change (childsafe)
Load symbol show when thermostat is activating the load
Antenna symbol show when the remote control is in
control
• Hand symbol show when the unit is under local control
• Zone number show when SFG main switch is operated
(17-24)
The Repeater has a
separate power supply from
a 6 V DC adapter.
Specifications
Standards
•
•
•
•
•
•
•
•
EN61000-6-1:2004
EN61000-6-3:2004
EN61000-4-2:2001
EN60730-1:2003
EN300220-1:2006
EN300220-2:2006
EN301489-1:2005
EN301489-3:2002
Rated voltage: 230 Volt (SFG2) 400 Volt (SFG4)
Rated current: 16 Amp.
Mains switch 2-pole
Safety protection class: IP20
Insulation class: II
Load relay: 1-pole
Radio transmission at 433,93 MHz
Sensitivity -110 dBm
RF
Signal repeater
Art.no.: 910087
CRG
Thermostat, plug-in.
CRG2 (230V) Art.no.: 910066
CRG4 (400V) Art.no.: 910067
CRMG
Master thermostat,
plug-in (SLA 5/24)
CRMG2 (230V) Art.no.: 910068
CRMG4 (400V) Art.no.: 910069
SFG
Floor heat thermostat
SFG2 (230V) Art.no.: 910100
SFG4 (400V) Art.no.: 910101
SMG
Master thermostat
Wallmounted
SMG2 (230V) Art.no.: 910105
SMG4 (400V) Art.no.: 910106
SXG
Relay, fixed installation
SXG2 (230V) Art.no.: 910110
SXG4 (400V) Art.no.: 910111
COG-e
Relay, with lead and plug
Art.no.: 910074
Connection
Input:
2-pole connector
block 2,5
Measures
SXG
CSW
Wall sensor
Art.no.: 910085
Output:
2-pole connector
block 2,5
GSM
Complete
Art.no.: 910081
GSM
Basic
Art.no.: 910080
(Available upon request)
TECHNICAL DATA
Harmony 5000
RELAY FIXED INSTALLATION
SXG2 (230 V) Art.no.: 910110
SXG4 (400 V) Art.no.: 910111
Wiring diagram
Installation
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertising